3 Enclosed Control Products 0115 ABB Low Voltage
Direct-on-line starters
IP65 plastic - IP55 metal enclosure
Direct on Line IP65 PLASTIC Enclosure 400v up to 7.5kW
100-250v coil
Three Phase
Single Phase
400V [AC3]
230V [AC3]
KW
hp
KW
hp
5.5
7.5
1.5
2.0
7.5
10.0
2.2
3.0
Dimensions mm
H
W
D
230
106
127
230
106
127
Part No
Product Hierarchy 3600001
Order Code
DL205P
1TVC230050P5699
DL207P
1TVC230070P5699
250-500v coil
5.5
7.5
7.5
10.0
DL405P
1TVC400050P5699
DL407P
1TVC400070P5699
Part No
Product Hierarchy 3600001
Order Code
DL205S
1TVC230050S5699
DL207S
1TVC230070S5699
DL405S
1TVC400050S5699
DL407S
1TVC400070S5699
Direct on Line IP55 METAL Enclosure 400v up to 7.5kW
100-250v coil
Three Phase
400V [AC3]
KW
Single Phase
230V [AC3]
hp
KW
hp
5.5
7.5
1.5
2.0
7.5
10.0
2.2
3.0
Dimensions mm
H
W
D
184
184
165
250-500v coil
5.5
7.5
7.5
10.0
184
184
165
DL205S
Direct on Line with Isolator IP55 METAL Enclosure 400v up to 7.5kW
100-250v coil
Three Phase
400V [AC3]
KW
hp
Single Phase
230V [AC3]
KW
hp
5.5
7.5
1.5
2.0
7.5
10.0
2.2
3.0
Dimensions mm
H
W
D
184
184
180
Part No
Product Hierarchy 3600001
Order Code
DI205S
1TVC230051S5699
DI207S
1TVC230071S5699
250-500v coil
DI205S
5.5
7.5
7.5
10.0
184
184
180
DI405S
1TVC400051S5699
DI407S
1TVC400071S5699
Direct on Line Reversing IP55 METAL Enclosure 400v up to 7.5kW
100-250v coil
Three Phase
Single Phase
400V [AC3]
230V [AC3]
Dimensions mm
KW
hp
KW
hp
H
W
D
Part No
Product Hierarchy 3600001
Order Code
7.5
10.0
2.2
3.0
184
184
165
DR207S
1TVC230072S5699
184
184
165
DR407S
1TVC400072S5699
250-500v coil
7.5
DR207S
4 Enclosed Control Products 0115 ABB Low Voltage
10.0
Star delta starters
IP55 metal enclosure
Star-Delta IP65 METAL Enclosure 400V up to 22kW
• Star-Delta Starters in metal enclosure IEC 947-4-1.
• All three phase star delta starters, are complete with pushbuttons, and 100-250v or 250-500v coils.
• Resetting of overload via stop button.
• Overload for standard motor duty is supplied separately.
Note:
The overload should be fitted in the Delta loop, therefore overload rating equal to FLC x by 0.58*
Star-Delta IP55 METAL Enclosure 400V up to 22kW
100-250v coil
Three Phase
400V [AC3]
Dimensions mm
KW
hp
H
W
D
Part No
Product Hierarchy 3600001
Order Code
15
20.0
184
284
165
SD215S
1TVC230153S5699
22.0
30.0
305
284
175
SD415S
1TVC400153S5699
15
20.0
184
284
165
SD222S
1TVC230223S5699
22.0
30.0
305
284
175
SD422S
1TVC400223S5699
250-500v coil
SD215S
Star-Delta with Isolator IP55 METAL Enclosure 400V up to 22kW
100-250v coil
Three Phase
400V [AC3]
Dimensions mm
KW
hp
H
W
D
Part No
Product Hierarchy 3600001
Order Code
15
20.0
184
284
180
SI215S
1TVC230154S5699
22.0
30.0
305
284
190
SI415S
1TVC400154S5699
15
20.0
184
284
180
SI222S
1TVC230224S5699
22.0
30.0
305
284
190
SI422S
1TVC400224S5699
250-500v coil
SI215S
5 Enclosed Control Products 0115 ABB Low Voltage
Overload protection
Selection
Description
The TF42 thermal overload relays are economic electromechanical protection devices for the main circuit. They offer reliable protection for motors
in the event of overload or phase failure. The devices have trip class 10.
The thermal overload relays are three pole relays with bimetal tripping elements. The motor current flows through the bimetal tripping elements and
heats them directly and indirectly. In case of an overload (over current), the bimetal elements bent as a result of the heating. This leads to a release
of the relay and a change of the contacts switching position (95-96 / 97-98).
– Manual or automatic reset selectable
– Phase loss sensitive acc. to IEC/EN 60947-4-1
– TEST and STOP function – Trip indication on the front
– Temperature compensation
– Suitable for three- and single-phase applications
TF42
TF42 0.10 to 38.0A
Setting range
Short-circuit
protective device
Trip class
A
0.10 ... 0.13
0.5 A, fuse type T
10
TF42-0.13
1SAZ721201R1005
0.13 ... 0.17
1.0 A, fuse type T
10
TF42-0.17
1SAZ721201R1008
0.17 ... 0.23
1.0 A, fuse type T
10
TF42-0.23
1SAZ721201R1009
0.23 ... 0.31
1.0 A, fuse type T
10
TF42-0.31
1SAZ721201R1013
0.31 ... 0.41
2.0 A, fuse type gG
10
TF42-0.41
1SAZ721201R1014
0.41 ... 0.55
2.0 A, fuse type gG
10
TF42-0.55
1SAZ721201R1017
0.55 ... 0.74
4.0 A, fuse type gG
10
TF42-0.74
1SAZ721201R1021
0.74 ... 1.00
6.0 A, fuse type gG
10
TF42-1.0
1SAZ721201R1023
1.00 ... 1.30
6.0 A, fuse type gG
10
TF42-1.3
1SAZ721201R1025
1.30 ... 1.70
10.0 A, fuse type gG
10
TF42-1.7
1SAZ721201R1028
1.70 ... 2.30
10.0 A, fuse type gG
10
TF42-2.3
1SAZ721201R1031
2.30 ... 3.10
10.0 A, fuse type gG
10
TF42-3.1
1SAZ721201R1033
3.10 ... 4.20
20.0 A, fuse type gG
10
TF42-4.2
1SAZ721201R1035
4.20 ... 5.70
20.0 A, fuse type gG
10
TF42-5.7
1SAZ721201R1038
5.70 ... 7.60
35.0 A, fuse type gG
10
TF42-7.6
1SAZ721201R1040
7.60 ... 10.0
35.0 A, fuse type gG
10
TF42-10
1SAZ721201R1043
10.0 ... 13.0
40.0 A, fuse type gG
10
TF42-13
1SAZ721201R1045
13.0 ... 16.0
40.0 A, fuse type gG
10
TF42-16
1SAZ721201R1047
16.0 ... 20.0
63.0 A, fuse type gG
10
TF42-20
1SAZ721201R1049
20.0 ... 24.0
63.0 A, fuse type gG
10
TF42-24
1SAZ721201R1051
24.0 ... 29.0
63.0 A, fuse type gG
10
TF42-29
1SAZ721201R1052
29.0 ... 35.0
80.0 A, fuse type gG
10
TF42-35
1SAZ721201R1053
35.0 ... 38.0/40.0
80.0 A, fuse type gG
10
TF42-38
1SAZ721201R1055
Part No
Star Delta Starter Overload selection
*Overload Calculation
Motor
FLC
Delta Loop
Setting
Motor
FLC
Delta Loop
Setting
5
2.9
18
10.4
6
3.5
20
11.6
7
4.0
25
14.5
8
4.6
30
17.4
9
5.2
35
20.3
10
5.8
40
23.2
12
7.0
45
26.1
14
8.1
50
29.0
16
9.3
55
32.0
Note: The overload should be fitted in the Delta loop, therefore overload rating equal to FLC x by 0.58*
6 Enclosed Control Products 0115 ABB Low Voltage
Product Hierarchy 1700009
Order Code
Heating & lighting
IP65 plastic - IP55 metal enclosure
Three & Four Pole Heating & Lighting Contactors IP65 PLASTIC Enclosure
100-250v coil (Including neutral terminal strip)
Heating
AC1
Amps
Amps per
pole
Fluorescent
Mercury
Amps per
pole
Tungsten
Main
Poles
Part No
Product Hierarchy 3600004
Order Code
25
16
16
4
HL025P
1TVC230025P5604
45
30
32
4
HL045P
1TVC230045P5604
HL025P
Three & Four Pole Heating & Lighting Contactors IP55 METAL Enclosure
100-250v coil (Including neutral terminal strip)
Heating
AC1
Amps
Amps per
pole
Fluorescent
Mercury
Amps per
pole
Tungsten
Main
Poles
Part No
Product Hierarchy 3600004
Order Code
25
16
16
4
HL025S
1TVC230025S5604
45
30
32
4
HL045S
1TVC230045S5604
70
40
42
3
HL063S
1TVC230063S5603
100
70
70
3
HL100S
1TVC230100S5603
HL025S
Dimensions
Enclosure
Part No
Plastic
HL•••25P4 - HL•••45P4
Metal
HL•••25S4 - HL•••45S4
HL•••63S3 - HL•••100S3
Height mm
Width mm
Depth mm
230
106
127
180
185
145
7 Enclosed Control Products 0115 ABB Low Voltage
Pushbutton stations
Plastic IP65 enclosures
Plastic Pushbutton Stations IP65
• IP65 thermoplastic control station complete with actuator, contact blocks and legend plate.
Supplied fully assembled. Other variations are available on request.
1GO
Dimensions
One Gang Pushbuttons
H
W
D
75
101
74
Mushroom Head 30mm (twist release) - to IEC60947-5-5
75
101
Emergency Stop 40mm (twist release) - to IEC60947-5-5
75
101
Mushroom Head 60mm (twist release) - to IEC60947-5-5
75
101
Emergency Stop 40mm (with key release) - to IEC60947-5-5
75
101
1 Way Start/Green
Part No
Product Hierarchy 3600003
Order Code
1GO
1TVC110000P3101
1RC
1TVC101000P3102
92
1RSC
1TVC101000P3203
107
1RSC-EN
1TVC101000P3204
107
1RMSC50
1TVC101000P3205
122
1RMSKC
1TVC101000P3206
Two-position switch
1H2O-I
1TVC110000P3107
Two-position key switch (key removable both positions)
1K2O-I
1TVC110000P3108
1H3I-O-II
1TVC110100P3109
1K3I-O-II
1TVC110100P3110
1 Way Stop/Red
Emergency Stops
1RSC-EN
Key Switches
Three position switch
75
101
74
Three position key switch (key removable in all positions)
1K2 O-I
Two Gang Pushbuttons
Start/Green and Stop/Red
75
141
79
2GORC
1TVC211000P3111
Start/Green and Red/Emergency Stop 40mm (twist release) to
IEC60947-5-5
75
141
107
2GORSC-EN
1TVC211000P3112
2GORC
8 Enclosed Control Products 0115 ABB Low Voltage
Pushbutton stations
IP55 stainless steel enclosures
Stainless Enclosures
Dimensions mm
1RSC-ENSS
Description
H
W
D
Emergency Stop 40mm (stay-put) - to EN418
Product Hierarchy 3600004
Order Code
Part No
100
140
100
1RSC-ENSS
1 Gang Empty Enclosure
-
-
55
01.001001.SS1
1TVC100000P5015
01.001001.SS1
2 Gang Empty Enclosure
-
-
55
01.001002.SS2
01.001002.SS2
3 Gang Empty Enclosure
-
-
55
01.001003.SS3
01.001003.SS3
Terminal boxes
Plastic IP65 enclosures
Terminals in Enclosures
Description
Terminal Box 2.5mm IP55 plastic enclosure
Terminal Box 4mm IP55 plastic enclosure
10TERM2.5
[A]
No of
Terms
1th
Dimensions mm
H
W
D
Part No
Product Hierarchy 3600005
Order Code
5
24
5TERM2.5
1TVC151800S2349
10
24
10TERM2.5
1TVC151800S2347
5
32
5TERM4
1TVC151800S2350
10
32
10TERM4
1TVC151800S2348
118
163
72
9 Enclosed Control Products 0115 ABB Low Voltage
Notes
10 Enclosed Control Products 0115 ABB Low Voltage
ABB Ltd
Tower Court
Foleshill Enterprise Park
Courtaulds Way
Coventry CV6 5NX
Tel:
Fax:
0333 999 9900
0333 999 9901
Email: LV.Enquiries@gb.abb.com
Twitter: @ABBUKLVP
Note: We reserve the right to make technical changes or modify
the contents of this document without prior notice. With regard to
purchase orders, the agreed particulars shall prevail. ABB Ltd
does not accept any responsibility whatsoever for potential errors
or possible lack of information in this document.
We reserve all rights in this document and in the subject matter
and illustrations contained therein. Any reproduction, disclosure
to third parties or utilization of its contents – in whole or in parts –
is forbidden without prior written consent of ABB Ltd.
Copyright © 2015 ABB Ltd
All rights reserved
www.abb.co.uk/lowvoltage
Power and productivity
for a better world
TM
© Copyright ABB Ltd 9AKK106354A1398
Contact us
很抱歉,暂时无法提供与“1RMSC50”相匹配的价格&库存,您可以联系我们找货
免费人工找货