1SBL237082R1122

1SBL237082R1122

  • 厂商:

    ABB

  • 封装:

  • 描述:

    ABB - JOKAB - 1SBL237082R1122 - Contactor, 17 A, DIN Rail, Panel, 690 V, 3PST-NO, 3 Pole, 15 kW

  • 数据手册
  • 价格&库存
1SBL237082R1122 数据手册
AFS26-30-22-11 Products Low Voltage Products and Systems Control Products Contactors Block Contactors General Information Extended Product Type: AFS26-30-22-11 Product ID: 1SBL237082R1122 EAN: 3471523005471 Catalog Description: AFS26-30-22-11 24-60V50/60HZ 20-60VDC Contactor Long Description: AFS09 ... AFS38 contactors are designed for machine safety applications. They are delivered with fixed front-mounted auxiliary contact blocks makin g them ideal for monitoring and controlling circuits. Mechanically linked an d mirror contacts make your system safer. - control circuit with electronic c oil interface: - 24...60 V AC, 20...60 V DC and 100...250 V AC / DC operate d accepting a wide control voltage range - reduced panel energy consumpt ion - mirror and mechanically linked contacts, with front marked symbol ac c. to IEC60947-5-1, always guaranteeing the right contactor status - frontmounted auxiliary contact block: - permanently fixed - protective cover to p revent manual operation - yellow housing for easy identification - minimum switching capacity 12 V / 3 mA, with a failure rate 10-7 acc. to IEC 60947-5 -4 - built-in surge suppression Ordering Minimum Order Quantity: 1 piece Customs Tariff Number: 85364900 Popular Downloads Instructions and Manuals: 1SBC101052M6801 Dimensions Product Net Width: 45 mm Product Net Depth / Length: 119.5 mm Product Net Height: 86 mm Product Net Weight: 0.36 kg Technical Number of Main Contacts NO: 3 Number of Main Contacts NC: 0 Number of Auxiliary Contacts NO: 2 Number of Auxiliary Contacts NC: 2 Standards: IEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1, UL 508, CSA C22.2 N°14 Rated Operational Voltage: Auxiliary Circuit 690 V Main Circuit 690 V Rated Frequency (f): Auxiliary Circuit 50 / 60 Hz Main Circuit 50 / 60 Hz Conventional Free-air Thermal acc. to IEC 60947-4-1, Open Contactors q = 40 °C 50 A acc. to IEC 60947-5-1, q = 40 °C 16 A Current (Ith): Rated Operational Current AC-1 (Ie): Rated Operational Current AC-3 (Ie): Rated Operational Power AC-3 (Pe): Rated Operational Current AC-15 (Ie): Rated Short-time Withstand Current (Icw): (690 V) 40 °C 45 A (690 V) 60 °C 40 A (690 V) 70 °C 32 A (220 (380 (415 (440 (500 (690 / 230 / 240 V) 60 °C 26 A / 400 V) 60 °C 26 A V) 60 °C 26 A V) 60 °C 26 A V) 60 °C 23 A V) 60 °C 17 A (220 (380 (400 (415 (440 (500 (690 / 230 / 240 V) 6.5 kW / 400 V) 11 kW V) 11 kW V) 11 kW V) 15 kW V) 15 kW V) 15 kW (220 (24 / (400 (500 (690 / 240 V) 4 A 127 V) 6 A / 440 V) 3 A V) 2 A V) 2 A at 40 °C Ambient at 40 °C Ambient at 40 °C Ambient at 40 °C Ambient at 40 °C Ambient for 0.1 s 140 A for 1 s 100 A Temp, Temp, Temp, Temp, Temp, in in in in in Free Free Free Free Free Air, Air, Air, Air, Air, from from from from from a a a a a Cold Cold Cold Cold Cold State State State State State 10 s 350 A 15 min 50 A 1 min 150 A 1 s 700 A 30 s 225 A Maximum Breaking Capacity: cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 500 A cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 200 A Maximum Electrical Switching AC-1 600 cycles per hour AC-15 1200 cycles per hour AC-2 / AC-4 150 cycles per hour AC-3 1200 cycles per hour DC-13 900 cycles per hour Frequency: Rated Operational Current DC-13 (Ie): (110 V) 0.55 A / 60 W (220 V) 0.27 A / 60 W (400 V) 0.15 A / 60 W (500 V) 0.13 A / 65 W (600 V) 0.1 A / 60 W (125 V) 0.55 A / 69 W (24 V) 6 A / 144 W (250 V) 0.27 A / 68 W (48 V) 2.8 A / 134 W (72 V) 1 A / 72 W Rated Insulation Voltage (Ui): acc. to UL/CSA 600 V acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V Rated Impulse Withstand Voltage 6 kV (Uimp): Maximum Mechanical Switching 3600 cycles per hour Frequency: Rated Control Circuit Voltage (Uc): 50 Hz 24 ... 60 V 60 Hz 24 ... 60 V DC Operation 20 ... 60 V Operate Time: Between Between Between Between Connecting Capacity Main Circuit: Flexible with Insulated Ferrule 1x 1.5 ... 10 mm² Flexible with Insulated Ferrule 2x 1.5 ... 4 mm² Flexible with Ferrule 1/2x 1.5 ... 10 mm² Rigid 1/2x 2.5 ... 10 mm² Connecting Capacity Auxiliary Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² Rigid 1/2x 1 ... 2.5 mm² Circuit: Connecting Capacity Control Circuit: Coil Coil Coil Coil De-energization and NC Contact Closing 13 ... 98 ms De-energization and NO Contact Opening 11 ... 95 ms Energization and NC Contact Opening 38 ... 90 ms Energization and NO Contact Closing 40 ... 95 ms Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² Rigid 1/2x 1 ... 2.5 mm² Wire Stripping Length: Auxiliary Circuit 10 mm Control Circuit 10 mm Main Circuit 14 mm Degree of Protection: acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20 acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20 Terminal Type: Screw Terminals Environmental Ambient Air Temperature: Close to Contactor for Storage -60 ... +80 °C Close to Contactor Fitted with Thermal O/L Relay -25 ... +60 °C Close to Contactor without Thermal O/L Relay -40 ... +70 °C Climatic Withstand: Category B according to IEC 60947-1 Annex Q Maximum Operating Altitude 3000 m Permissible: Resistance to Vibrations acc. to 5 ... 300 Hz 4 g closed position / 2 g open position IEC 60068-2-6: Resistance to Shock acc. to IEC 60068-2-27: Closed, Closed, Closed, Closed, Closed, Shock Shock Shock Shock Shock Direction: Direction: Direction: Direction: Direction: A 30 g B1 25 g B2 15 g C1 25 g C2 25 g Technical UL/CSA General Use Rating UL/CSA: (600 V AC) 45 A Horsepower Rating UL/CSA: (120 (240 (200 (220 (440 (550 Tightening Torque UL/CSA: V AC) Single V AC) Single ... 208 V AC) ... 240 V AC) ... 480 V AC) ... 600 V AC) Phase 2 Hp Phase 3 Hp Three Phase Three Phase Three Phase Three Phase Auxiliary Circuit 11 in·lb Control Circuit 11 in·lb Main Circuit 22 in·lb Certificates and Declarations (Document Number) CB Certificate: CB_SE-80872M3 cUL Certificate: UL_20180227_E312527_7_1 Declaration of Conformity - CE: 1SBD250022U1000 Instructions and Manuals: 1SBC101052M6801 UL Listing Card: E312527 Container Information Package Level 1 Units: 1 piece Package Level 1 Width: 87 mm Package Level 1 Depth / Length: 121 mm Package Level 1 Height: 47 mm Package Level 1 Gross Weight: 0.36 kg Package Level 1 EAN: 3471523005471 Package Level 2 Units: 36 piece Package Level 2 Width: 250 mm Package Level 2 Depth / Length: 300 mm 7-1/2 Hp 7-1/2 Hp 15 Hp 20 Hp Package Level 2 Height: 315 mm Package Level 2 Gross Weight: 12.96 kg Package Level 3 Units: 864 piece Classifications Object Classification Code: Q ETIM 4: EC000066 - Magnet contactor, AC-switching ETIM 5: EC000066 - Magnet contactor, AC-switching ETIM 6: EC000066 - Power contactor, AC switching ETIM 7: EC000066 - Power contactor, AC switching
1SBL237082R1122 价格&库存

很抱歉,暂时无法提供与“1SBL237082R1122”相匹配的价格&库存,您可以联系我们找货

免费人工找货
1SBL237082R1122
    •  国内价格
    • 1+1319.90687
    • 5+1187.91618
    • 10+1161.51804
    • 25+1073.52425
    • 50+1011.92860

    库存:59