0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
1SBL347082R1122

1SBL347082R1122

  • 厂商:

    ABB

  • 封装:

  • 描述:

    ABB - JOKAB - 1SBL347082R1122 - Contactor, 25 A, DIN Rail, Panel, 690 V, 3PST-NO, 3 Pole, 22 kW

  • 数据手册
  • 价格&库存
1SBL347082R1122 数据手册
AFS40-30-22-11 Products Low Voltage Products and Systems Control Products Contactors Block Contactors General Information Extended Product Type: AFS40-30-22-11 Product ID: 1SBL347082R1122 EAN: 3471523157613 Catalog Description: AFS40-30-22-11 24-60V50/60HZ 20-60VDC Contactor Long Description: AFS40 ... AFS96 contactors are designed for machine safety applications. They are delivered with fixed front-mounted auxiliary contact blocks makin g them ideal for monitoring and controlling circuits. Mechanically linked an d mirror contacts make your system safer. - control circuit with electronic c oil interface: - 24...60 V AC, 20...60 V DC and 100...250 V AC / DC operate d accepting a wide control voltage range - reduced panel energy consumpt ion - mirror and mechanically linked contacts, with front marked symbol ac c. to IEC60947-5-1, always guaranteeing the right contactor status - frontmounted auxiliary contact block: - permanently fixed - protective cover to p revent manual operation - yellow housing for easy identification - minimum switching capacity 12 V / 3 mA, with a failure rate 10-7 acc. to IEC 60947-5 -4 - built-in surge suppression Ordering Minimum Order Quantity: 1 piece Customs Tariff Number: 85364900 Popular Downloads Instructions and Manuals: 1SBC101052M6801 Dimensions Product Net Width: 55 mm Product Net Depth / Length: 144 mm Product Net Height: 125.5 mm Product Net Weight: 1.16 kg Technical Number of Main Contacts NO: 3 Number of Main Contacts NC: 0 Number of Auxiliary Contacts NO: 2 Number of Auxiliary Contacts NC: 2 Rated Operational Voltage: Auxiliary Circuit 690 V Main Circuit 690 V Rated Frequency (f): Auxiliary Circuit 50 / 60 Hz Main Circuit 50 / 60 Hz Conventional Free-air Thermal acc. to IEC 60947-4-1, Open Contactors q = 40 °C 105 A acc. to IEC 60947-5-1, q = 40 °C 16 A Current (Ith): Rated Operational Current AC-1 (Ie): Rated Operational Current AC-3 (Ie): Rated Operational Power AC-3 (Pe): Rated Operational Current AC-15 (Ie): Rated Short-time Withstand Current (Icw): (690 V) 40 °C 70 A (690 V) 60 °C 60 A (690 V) 70 °C 50 A (220 (380 (415 (440 (500 (690 / 230 / 240 V) 60 °C 40 A / 400 V) 60 °C 40 A V) 60 °C 40 A V) 60 °C 40 A V) 60 °C 35 A V) 60 °C 25 A (220 (380 (400 (415 (440 (500 (690 / 230 / 240 V) 11 kW / 400 V) 18.5 kW V) 18.5 kW V) 22 kW V) 22 kW V) 22 kW V) 22 kW (220 (24 / (400 (500 (690 / 240 V) 4 A 127 V) 6 A / 440 V) 3 A V) 2 A V) 2 A at 40 °C Ambient at 40 °C Ambient at 40 °C Ambient at 40 °C Ambient at 40 °C Ambient for 0.1 s 140 A for 1 s 100 A Temp, Temp, Temp, Temp, Temp, in in in in in Free Free Free Free Free Air, Air, Air, Air, Air, from from from from from a a a a a Cold Cold Cold Cold Cold State State State State State 10 s 600 A 15 min 110 A 1 min 250 A 1 s 1000 A 30 s 350 A Maximum Breaking Capacity: cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 950 A cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 600 A Maximum Electrical Switching AC-1 600 cycles per hour AC-15 1200 cycles per hour AC-2 / AC-4 150 cycles per hour AC-3 1200 cycles per hour DC-13 900 cycles per hour Frequency: Rated Operational Current DC-13 (Ie): (110 V) 0.55 A / 60 W (220 V) 0.27 A / 60 W (400 V) 0.15 A / 60 W (500 V) 0.13 A / 65 W (600 V) 0.1 A / 60 W (125 V) 0.55 A / 69 W (24 V) 6 A / 144 W (250 V) 0.27 A / 68 W (48 V) 2.8 A / 134 W (72 V) 1 A / 72 W Rated Insulation Voltage (Ui): acc. to UL/CSA 600 V acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V Rated Impulse Withstand Voltage 6 kV (Uimp): Maximum Mechanical Switching 3600 cycles per hour Frequency: Rated Control Circuit Voltage (Uc): 50 Hz 24 ... 60 V 60 Hz 24 ... 60 V DC Operation 20 ... 60 V Operate Time: Between Between Between Between Connecting Capacity Main Circuit: Flexible with Insulated Ferrule 1/2x 4 ... 35 mm² Flexible with Ferrule 1/2x 4 ... 35 mm² Rigid 1/2x 6 ... 3 5 mm² Connecting Capacity Auxiliary Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² Rigid 1/2x 1 ... 2.5 mm² Circuit: Connecting Capacity Control Circuit: Coil Coil Coil Coil De-energization and NC Contact Closing 19 ... 105 ms De-energization and NO Contact Opening 17 ... 100 ms Energization and NC Contact Opening 38 ... 95 ms Energization and NO Contact Closing 42 ... 100 ms Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² Rigid 1/2x 1 ... 2.5 mm² Wire Stripping Length: Main Circuit 16 mm Degree of Protection: acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20 acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10 Terminal Type: Screw Terminals Environmental Ambient Air Temperature: Close to Contactor for Storage -60 ... +80 °C Close to Contactor Fitted with Thermal O/L Relay -25 ... +60 °C Close to Contactor without Thermal O/L Relay -40 ... +70 °C Climatic Withstand: Category B according to IEC 60947-1 Annex Q Maximum Operating Altitude 3000 m Permissible: Resistance to Vibrations acc. to 5 ... 300 Hz 3 g closed position / 3 g open position IEC 60068-2-6: Resistance to Shock acc. to IEC 60068-2-27: Closed, Closed, Closed, Closed, Closed, Shock Shock Shock Shock Shock Direction: Direction: Direction: Direction: Direction: A 25 g B1 25 g B2 15 g C1 25 g C2 25 g Technical UL/CSA General Use Rating UL/CSA: (600 V AC) 60 A Horsepower Rating UL/CSA: (120 (240 (200 (220 (440 (550 Tightening Torque UL/CSA: V AC) Single V AC) Single ... 208 V AC) ... 240 V AC) ... 480 V AC) ... 600 V AC) Phase 3 Hp Phase 7-1/2 Hp Three Phase 10 Three Phase 15 Three Phase 30 Three Phase 40 Auxiliary Circuit 11 in·lb Control Circuit 11 in·lb Main Circuit 35 in·lb Certificates and Declarations (Document Number) CB Certificate: CB_SE_77418M1 cUL Certificate: UL_20170607-E312527-14-1 Declaration of Conformity - CE: 1SBD250022U1000 Instructions and Manuals: 1SBC101052M6801 UL Listing Card: E312527 Container Information Package Level 1 Units: 1 piece Package Level 1 Width: 167 mm Package Level 1 Depth / Length: 180 mm Package Level 1 Height: 97 mm Package Level 1 Gross Weight: 1.16 kg Package Level 1 EAN: 3471523157613 Package Level 2 Units: 6 piece Package Level 2 Width: 250 mm Package Level 2 Depth / Length: 300 mm Package Level 2 Height: 300 mm Package Level 2 Gross Weight: 6.96 kg Package Level 3 Units: 144 piece Hp Hp Hp Hp Classifications Object Classification Code: Q ETIM 4: EC000066 - Magnet contactor, AC-switching ETIM 5: EC000066 - Magnet contactor, AC-switching ETIM 6: EC000066 - Power contactor, AC switching ETIM 7: EC000066 - Power contactor, AC switching
1SBL347082R1122 价格&库存

很抱歉,暂时无法提供与“1SBL347082R1122”相匹配的价格&库存,您可以联系我们找货

免费人工找货