1SFL451001R8411

1SFL451001R8411

  • 厂商:

    ABB

  • 封装:

  • 描述:

    ABB - 1SFL451001R8411 - Contactor, 110 A, DIN Rail, 110 VAC, DPDT, 3 Pole, 55 kW

  • 数据手册
  • 价格&库存
1SFL451001R8411 数据手册
A110-30-11 110V 50Hz / 110-120V 60Hz General Information Extended Product Type: Product ID: EAN: Catalog Description: Long Description: A110-30-11 110V 50Hz / 110-120V 60Hz 1SFL451001R8411 7320500141588 A110-30-11 110V 50Hz / 110-120V 60Hz Contactor A 3-phase Contactor suitable for various applications such as Motor starting, Isolation, Bypass and Distribution application up to max 1000 V.Operated with control voltage, versions from 24….690 AC, 50 and 60 Hz Categories Products » Low Voltage Products and Systems » Control Products » Contactors » Block Contactors Ordering Minimum Order Quantity: Customs Tariff Number: EAN: 1 piece 85364900 7320500141588 Dimensions Product Net Depth: Product Net Height: Product Net Weight: Product Net Width: 123.5 mm 148.0 mm 2.040 kg 102.0 mm Container Information Package Level 1 Width: Package Level 1 Length: Package Level 1 Height: Package Level 1 Gross Weight: Package Level 1 EAN: Package Level 1 Units: 140 mm 140 mm 170 mm 2 kg 7320500141588 1 piece Technical Number of Main Contacts NC: Number of Auxiliary Contacts NO: Number of Auxiliary Contacts NC: Rated Operational Voltage: Rated Frequency (f): Conventional Free-air Thermal Current (Ith): Rated Operational Current AC-1 (Ie): Rated Operational Current AC-3 (Ie): Rated Operational Power AC-3 (Pe): Rated Breaking Capacity AC-3 acc. to IEC 60947-4-1: Rated Making Capacity AC-3 acc. to IEC 60947-4-1: Short-Circuit Protective Devices: Rated Short-time Withstand Current (Icw): 0 1 1 Main Circuit 1000 V Main Circuit 50/60 Hz acc. to IEC 60947-4-1, Open Contactors q = 40 °C 160 A (690 V) 55 °C 145 A (690 V) 40 °C 160 A (690 V) 70 °C 130 A (1000 V) 55 °C 30 A (690 V) 55 °C 82 A (415 V) 55 °C 110 A (220 / 230 / 240 V) 55 °C 110 A (440 V) 55 °C 100 A (380 / 400 V) 55 °C 110 A (500 V) 55 °C 100 A (500 V) 59 kW (1000 V) 40 kW (690 V) 75 kW (220 / 230 / 240 V) 30 kW (380 / 400 V) 55 kW (440 V) 59 kW (415 V) 59 kW 8 x Ie AC-3 10 x Ie AC-3 gG Type Fuses 200 A at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 500 A at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 175 A at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 800 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1320 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 350 A Maximum Breaking Capacity: Maximum Electrical Switching Frequency: Rated Operational Current DC-1 (Ie): Rated Operational Current DC-3 (Ie): Rated Operational Current DC-5 (Ie): Rated Insulation Voltage (Ui): Rated Impulse Withstand Voltage (Uimp): Mechanical Durability: Maximum Mechanical Switching Frequency: Coil Operating Limits: Rated Control Circuit Voltage (Uc): cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1160 A cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 800 A AC-3 300 cycles per hour AC-1 300 cycles per hour AC-2 / AC-4 150 cycles per hour (110 V) 2 Poles in Series, 40 °C 160 A (220 V) 3 Poles in Series, 40 °C 160 A (110 V) 2 Poles in Series, 40 °C 160 A (220 V) 3 Poles in Series, 40 °C 160 A (110 V) 2 Poles in Series, 40 °C 160 A (220 V) 3 Poles in Series, 40 °C 160 A acc. to UL/CSA 600 V acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V Main Circuit 8 kV 10 million 3600 cycles per hour (acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C) °C 60 Hz 110 … 120 V 50 Hz 110 V Coil Consumption: Pull-in at Max. Rated Control Circuit Voltage 60 Hz 450 V·A Holding at Max. Rated Control Circuit Voltage 50 Hz 22 V·A Pull-in at Max. Rated Control Circuit Voltage 50 Hz 350 V·A Holding at Max. Rated Control Circuit Voltage 60 Hz 26 V·A Operate Time: Between Coil Energization and NO Contact Closing 10 ... 25 ms Between Coil De-energization and NO Contact Opening 10 ... 18 ms Between Coil De-energization and NC Contact Closing 7 ... 15 ms Between Coil Energization and NC Contact Opening 7 ... 22 ms Connecting Capacity Main Circuit: Flexible with Cable End 1x10…70 mm² Bar 30 mm² Rigid 2x6…65 mm² Connecting Capacity Auxiliary Solid 1x1…4 mm² Circuit: Flexible with Insulated Ferrule 2x0.75…2.5 mm² Stranded 2x1…4 mm² Flexible 2x0.75…2.5 mm² Flexible with Ferrule 1x0.75…2.5 mm² Degree of Protection: acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10 Connecting terminals (delivered in M8 hexagon socket screw with single connector open position) Main poles: Terminal Type: Cable Clamp Number of Main Contacts NO: 3 Environmental Maximum Operating Altitude Permissible: Resistance to Shock acc. to IEC 60068-2-27: RoHS Status: Ambient Air Temperature: 3000 m Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: A 20 g Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: C2 20 g Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: A 20 g Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: B1 15 g Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: B2 15 g Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: C1 20 g Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: C2 20 g Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: B1 5 g Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: C1 20 g Following EU Directive 2002/95/EC August 18, 2005 and amendment Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25…+50 °C Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40…+70 °C Close to Contactor for Storage -60…+80 °C Technical UL/CSA General Use Rating UL/CSA: Horsepower Rating UL/CSA: Maximum Operating Voltage UL/CSA: (600 V AC) 140 A (208 V AC) Three Phase 30 Hp (440 ... 480 V AC) Three Phase 75 Hp (550 ... 600 V AC) Three Phase 100 Hp (220 ... 240 V AC) Three Phase 40 Hp (200 V AC) Three Phase 30 Hp Main Circuit 600 V Certificates and Declarations (Document Number) Instructions and Manuals: 5309660-60 BV Certificate: CB Certificate: CCC Certificate: CSA Certificate: Data Sheet, Technical Information: Declaration of Conformity - CE: DNV Certificate: GL Certificate: LOVAG Certificate: LR Certificate: RINA Certificate: RMRS Certificate: RoHS Information: 07172/D0 BV SE-69487 CQC_2002010304008904 314005 1SBC100122C0202 1SFA1-63 DNV_E-12191 GL_99358-97HH SE-9645071-2 LR_12-70027-E1 ELE060313XG/001 RMRS_12-03683-315 1SFC101046D0203 Classifications ETIM 4: ETIM 5: UNSPSC: Object Classification Code: EC000066 - Magnet contactor, AC-switching EC000066 - Magnet contactor, AC-switching 39121529 Q
1SFL451001R8411 价格&库存

很抱歉,暂时无法提供与“1SFL451001R8411”相匹配的价格&库存,您可以联系我们找货

免费人工找货