1SVR427030R0000

1SVR427030R0000

  • 厂商:

    ABB

  • 封装:

  • 描述:

    ABB - 1SVR427030R0000 - AC/DC DIN Rail Power Supply (PSU), ITE & Hazardous Locations, 1 Output, 18 W...

  • 数据手册
  • 价格&库存
1SVR427030R0000 数据手册
Data sheet Power supply CP-E 24/0.75 Primary switch mode power supply 2CDC 271 017 F0006 The CP-E range offers enhanced functionality while the number of different types has been considerably reduced. Now all power supply units can be operated at an ambient temperature of up to +70 °C. Characteristics –– Rated output voltage 24 V DC –– Output voltage adjustable via front‑face rotary potentiometer “OUTPUT Adjust” –– Rated output current 0.75 A –– Rated output power 18 W –– Wide range input 100‑240 V AC (90‑264 V AC, 120‑375 V DC) –– Typical efficiency of 77 % –– Low power dissipation and low heating –– Free convection cooling (no forced cooling with ventilators) –– Ambient temperature range during operation ‑20...+70 °C –– Open‑circuit, overload and short‑circuit stable –– Integrated input fuse –– Redundancy unit CP‑RUD offering true redundancy, available as accessory –– LEDs for status indication Approvals A UL 508, CAN/CSA C22.2 No.107.1 1) H UL 1310, CAN/CSA C22.2 No.223 (Class 2 Power Supply) H ANSI/ISA‑12.12, CAN/CSA C22.2 No. 213 (Class I, Div. 2, hazardous locations) H UL 60950, CAN/CSA C22.2 No.60950 1) R E EAC 1) CCC 1) Approval refers to rated input voltage Uin Marks a CE b RCM Order data Type Input voltage range Rated output voltage / current Order code CP-E 24/0.75 90‑264 V AC / 120-375 V DC 24 V DC / 0.75 A 1SVR 427 030 R0000 Order data – accessories Type Description Order code CP‑RUD Redundancy unit 1SVR 423 418 R9000 The CP‑RUD provides decoupling of two CP‑E power supply units ≤ 35 V and < 5 A. Functions 1 OUTPUT L+, L–: terminals – output 1 2 INPUT L, N, PE: terminals – input 3 4 5 6 3 LOW: red LED – output voltage too low 4 OK: green LED – output voltage OK 5 OUTPUT Adjust: 2 potentiometer – adjustment of the output voltage 6 Circuit diagram Application The primary switch mode power supply offers two voltage input ranges. This enables the supply with AC or DC. Furthermore it is equipped with two generous capacitors, which ensure mains buffering of at least 75 ms (at 230 V AC). That is why the devices can be used worldwide also in high fluctuating networks and battery‑powered plants. Operating mode By means of the potentiometer “OUTPUT Adjust” the output voltage can be adjusted within a range of 21.6 to 28.8 V DC. Thus, the power supply can be optimally adapted to the application, e.g. compensating the voltage drop caused by a long line length. The green LED “OK” is lightening during proper operation. The red LED “LOW” is lightening when the output voltage is too low. 2 - Power supply CP-E 24/0.75 | Data sheet Installation Mounting 2CDC272057F0b06 2CDC 272 057 F0b06 The switch mode power supply can be snapped on a DIN rail according to IEC/EN 60715 as shown in the accompanying picture. For that the device is set with its mounting rail slide on the upper edge of the mounting rail and locked by lifting it downwards. Demounting 2CDC 272 058 F0b06 2CDC272058F0b06 Remove the switch mode power supply as shown in the accompanying picture. For that the latching lever is pulled downwards by means of the screwdriver. Alternatively you can press the unlock button to release the device. Then in both cases the device can be unhinged from the mounting rail edge and removed. Mounting position 2CDC 272 059 F0b06 2CDC272059F0b06 The devices have to be mounted horizontally with the input terminals on the b ­ ottom. In order to ensure a sufficient convection, the minimum distance to other modules should not be less than 25 mm in vertical and horizontal direction. Data sheet | Power supply CP-E 24/0.75 - 3 Electrical connection Connect the input terminals L and N. The protective earth conductor PE must be connected. The i­nstallation must be executed acc. to EN 60950, provide a suitable disconnecting device (e. g. line ­protection switch) in the supply line. The input side is protected by an internal input fuse. Rate the lines for the maximum output current (considering the short‑circuit current) or provide a s­ eparate fuse protection. We recommend to choose the cable section as large as possible in order to minimize voltage drops. Observe the polarity. The device is overload, short‑circuit and open‑circuit proof. The secondary side of the power supply unit is electrically isolated from the input and internally not earthed (SELV) and can therefore be earthed by the user according to the needs with L+ or L‑ (PELV). Connection diagram L N L+ PWM L- PE PE N L 2CDC 272 054 F0b06 L+ 2CDC272054F0b06 L- 4 - Power supply CP-E 24/0.75 | Data sheet L+, L‑ Output voltage L, N Input voltage PE Protective earth Safety instructions and warnings The device must be installed by qualified persons only and in accordance with the specific national r­ egulations (e.g., VDE, etc.). The devices are maintenance-free chassis-mounted units. Disconnect system from supply network! Before any installation, maintenance or modification work: Disconnect the system from the supply n ­ etwork and protect against switching on. Before start of operation: Attention! Improper installation/operation may impair safety and cause operational difficulties or d ­ estruction of the unit. Before operation the following must be ensured: –– Connect to main according to the specific national regulations. –– Power supply cables and unit must be sufficiently fused. A disconnecting device has to be provided for the power supply to disengage unit and supply cables from supply mains if required. –– The protective earth conductor must be connected to the terminal PE (Protection class I) –– The secondary side of the power supply unit is not earthed and can be earthed by the user according to the needs with L+ or L-. –– Rate the output lines for the output current of the power supply and connect them with the correct polarity. –– In order to ensure sufficient air-cooling the distance to other devices has to be considered. In operation: –– Do not modify the installation (primary and secondary side)! High current! Risk of electric arcs and electric shocks (danger to life)! –– Risk of burns: Depending on the operation conditions the enclosure can become very hot. –– The internal fuse is not user-replaceable. If the internal fuse blows, most probably the device is ­defective. In this case, an examination of the switch mode power supply by the manufacturer is ­necessary. Attention! High voltage! Danger to life! The power supplies contain components with high stored energy and circuits with high voltage! Do not introduce any objects into the unit, and do not open the unit. With some units of this range the o ­ utput is capable of providing hazardous energy. Ensure that the service personnel is protected against i­nadvertent contact with parts carrying energy. Data sheet | Power supply CP-E 24/0.75 - 5 Technical data Data at Ta = 25 °C, Uin = 230 V AC and rated values, unless otherwise indicated Input circuits Supply circuits Rated input voltage Uin L,N 100-240 V AC Input voltage range AC 90-264 V DC 120-375 V AC 47-63 Hz Frequency range Typical input current at 115 V AC 335 mA at 230 V AC 210 mA Typical power consumption 22.8 W Inrush current limiting Discharge current at 115 V AC 10 A (max. 3 ms) at 230 V AC 18 A (max. 3 ms) input / output input / PE Power failure buffering time 0.25 mA 3.5 mA at 115 V AC min. 20 ms at 230 V AC min. 75 ms Internal input fuse 2 A slow-acting / 250 V AC Power factor correction (PFC) no User interface Indication of operational states Output voltage OK: green LED LOW: red LED V: output voltage OK V: output voltage too low Output circuit Rated output voltage L+, L- 24 V DC Tolerance of the output voltage 0 ... +1 % Adjustment range of the output voltage 21.6-28.8 V DC Rated output power 18 W Rated output current Ir Derating of the output current Maximum deviation with Ta ≤ 60 °C 60 °C < Ta ≤ 70 °C 0.75 A 2.5 %/°C load change statical ±2 % change of output voltage within the ±1 % input voltage range Control time < 2 ms Starting time after applying the supply voltage at Ir with 7000 µF Rise time max. 1.5 s at Ir max. 150 ms with 7000 µF max. 500 ms Fall time Residual ripple and switching peaks max. 1 s max. 150 ms BW = 20 MHz 50 mV Parallel connection yes, to enable redundancy Series connection yes, to increase voltage Resistance to reverse feed 1 s – max. 35 V DC Output circuit – no-load, overload and short-circuit behaviour Characteristic curve of output Hiccup-mode Short-circuit protection continuous short-circuit proof Short-circuit behaviour Hiccup-mode Overload protection output power limiting No-load protection continuous no-load stability Starting of capacitive loads 7000 µF 6 - Power supply CP-E 24/0.75 | Data sheet General data Power dissipation typ. 4.45 W Efficiency typ. 77 % Duty time 100 % Dimensions (W x H x D) 22.5 x 90 x 114 mm (0.89 x 3.54 x 4.49 in) Weight 0.143 kg (0.315 lb) Material of housing Plastic Mounting DIN rail (IEC/EN 60715), snap-on mounting without any tool Mounting position horizontal Minimum distance to other units horizontal / vertical 25 mm / 25 mm (0.98 in / 0.98 in) Degree of protection housing / terminals IP20 / IP20 Protection class I Electrical connection – input circuit / output circuit Connecting capacity fine-strand with wire end ferrule fine-strand without wire end ferrule 0.2-2.5 mm2 (24-14 AWG) rigid Stripping length 6 mm (0.24 in) Tightening torque 0.6 Nm (5 lb.in) Environmental data Ambient temperature range operation -20…+70 °C (-4...+158 °F) rated load -20...+60 °C (-4...+140 °F storage -25…+85 °C (-13...+185 °F) Damp heat 95 % RH, without condensation Vibration (sinusoidal) (IEC/EN 60068-2-6) 10-500 Hz, 2 G, along X, Y, Z each axis, 60 min. for each axis Shock (half-sine) (IEC/EN 60068-2-27) 15 G, 11 ms, 3 axis, 6 faces, 3 times for each face Isolation data Rated insulation voltage Ui input / output input / PE output / PE 3 kV AC 1.5 kV AC 0.5 kV AC; 0.71 kV DC Pollution degree 2 Overvoltage category II Standards / Directives Standards IEC/EN 60950‑1 Low Voltage Directive 2014/35/EU Protective low voltage SELV (IEC/EN 60950‑1) EMC Directive 2014/30/EU RoHS Directive 2011/65/EU Data sheet | Power supply CP-E 24/0.75 - 7 Electromagnetic compatibility Interference immunity to IEC/EN 61000-6-2 electrostatic discharge IEC/EN 61000-4-2 Level 4 (air discharge 15 kV / contact discharge 8 kV) radiated, radio-frequency, IEC/EN 61000-4-3 Level 3 (10 V/m) electrical fast transient / burst IEC/EN 61000-4-4 Level 4 (4 kV / 2.5 kHz) surge IEC/EN 61000-4-5 L-L Level 3 (2 kV) / L-PE Level 4 (4 kV) conducted disturbances, induced by IEC/EN 61000-4-6 Level 3 (10 V) power frequency magnetic fields IEC/EN 61000-4-8 Level 4 (30 A/m) voltage dips, short interruptions IEC/EN 61000-4-11 electromagnetic field radio-frequency fields and voltage variations dip: >95 % 10 ms / >30 % 500 ms interruptions: >95 % 5000 ms Interference emission IEC/EN 61000-6-3 high-frequency radiated IEC/CISPR 22, EN 55022 Class B high-frequency conducted IEC/CISPR 22, EN 55022 Class B IEC/EN 61000-3-2 Class D limits for harmonic current emissions 8 - Power supply CP-E 24/0.75 | Data sheet Technical diagrams Output behaviour The switch mode power supply CP‑E 24/0.75 is able to supply at 24 V DC output voltage and –– at an ambient temperature of: ≤ 60 °C a continuous output current of approx. 0.75 A –– at ambient temperatures of: 60 °C < Ta ≤ 70 °C the output power has to be reduced by 2.5 % per °C temperature increase. Temperature behaviour Pout [%] 2CDC272016F0211 100 90 80 70 60 50 40 30 20 10 -20 60 70 Ta [°C] Characteristic curve of temperature at rated load Dimensions in mm [inches] 22.5 0.89“ 90 3.54“ 4.49“ 2CDC272022F0011 114 CP-E 5/3.0 Dimensions accessories in mm [inches] 4.02“ 100 2CDC252188F0b05 .886“ 78 3.07“ 102 22,5 4.31“ 2CDC 252 188 F0b05 109,5 3.94“ CP-RUD Data sheet | Power supply CP-E 24/0.75 - 9 Further documentation Document title Document type Document number Electronic Products and Relays Technical catalogue 2CDC 110 004 C02xx Power Supply Units Application manual 2CDC 114 048 M020x Redundancy unit CP‑RUD Data sheet 2CDC 114 032 D0201 You can find the documentation on the internet at www.abb.com/lowvoltage -> Automation, control and protection -> Power supplies. CAD system files You can find the CAD files for CAD systems at http://abb-control-products.partcommunity.com -> Low Voltage Products & Systems -> Control Products -> Power Supplies. 10 - Power supply CP-E 24/0.75 | Data sheet Contact us Document number 2CDC 114 043 D0201 (08/2016) ABB STOTZ-KONTAKT GmbH P. O. Box 10 16 80 69006 Heidelberg, Germany Phone: +49 (0) 6221 7 01-0 Fax: +49 (0) 6221 7 01-13 25 E-mail: info.desto@de.abb.com You can find the address of your local sales organisation on the ABB home page http://www.abb.com/contacts -> Low Voltage Products and Systems Note: We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB AG does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents – in whole or in parts – is forbidden without prior written consent of ABB AG. Copyright © 2016 ABB All rights reserved
1SVR427030R0000 价格&库存

很抱歉,暂时无法提供与“1SVR427030R0000”相匹配的价格&库存,您可以联系我们找货

免费人工找货