0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
1SVR500110R0000.

1SVR500110R0000.

  • 厂商:

    ABB

  • 封装:

  • 描述:

    ABB - 1SVR500110R0000. - ANALOGUE TIMER, 0.05S-100H, SPDT

  • 数据手册
  • 价格&库存
1SVR500110R0000. 数据手册
Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. 2CDC 251 094 F0006 With their MDRC profile and a width of only 17.5 mm, the CT-D range timers are ideally suited for installation in distribution panels as well as for industrial applications where compact dimensions are required. Characteristics –– Rated control supply voltage 24‑48 V DC, 24‑240 V AC –– Single‑function timer OFF‑delay –– 7 time ranges (0.05 s ‑ 100 h) in one device –– Control input: voltage‑related triggering, polarized, capable of switching a parallel load –– Light‑grey enclosure in RAL 7035 –– 1 c/o (SPDT) contact (250 V / 6 A) –– Width of only 17.5 mm (0.689 in) –– 2 LEDs for the indication of operational states Approvals A UL 508, CAN/CSA C22.2 No.14 EAC R E CCC L RMRS Marks a CE b RCM Order data Type Rated control supply voltage Time range Output Order code CT-AHD.12 24‑48 V DC, 24‑240 V AC 0.05 s ‑ 100 h 1 c/o (SPDT) contact 1SVR 500 110 R0000 Functions Operating controls 1 Rotary switch for the preselection of the time range 2 Potentiometer with direct reading scale for the fine adjustment of the time delay 3 Indication of operational states U: green LED V control supply voltage applied W timing R: yellow LED V output relay energized 4 Circuit diagram 2CDC 251 094 F0006 4 1 3 2 Application With their structural form and their width of only 17.5 mm, the CT‑D range timers are ideally suited for installation in distribution panels. Operating mode The CT‑AHD.12 with 1 c/o (SPDT) contact and offers 7 time ranges, from 0.05 s to 100 h. The time delay range is rotary switch selectable on the front of the unit. The fine adjustment of the time delay is made via an internal potentiometer, with a direct reading scale, on the front of the unit. 2 - Electronic timer CT-AHD.12 | Data sheet Function descriptions / diagrams B OFF‑delay with auxiliary voltage This function requires continuous control supply voltage for timing. If control input A1‑Y1/B1 is closed, the output relay energizes immediately. If control input A1‑Y1/B1 is opened, the time delay starts. The green LED flashes during timing. When the selected time delay is complete, the output relay de‑energizes and the flashing green LED turns steady. If control input A1‑Y1/B1 recloses before the time delay is complete, the time delay is reset and the output relay does not change state. Timing starts again when control input A1‑Y1/B1 re‑opens. If control supply voltage is interrupted, the output relay de‑energizes and the time delay is reset. A1-A2 A1-Y1/B1 green LED 10 % of the min. rated control supply voltage Us Control circuit Control input, control function A1‑Y1/B1 start timing external Kind of triggering voltage‑related triggering Resistance to reverse polarity yes Polarized yes Capable of switching a parallel load yes Maximum cable length to the control inputs 50 m ‑ 100 pF/m Minimum control pulse length 20 ms Control voltage potential see rated control supply voltage Us Current /power consumption of the control input 24 V DC 3.8 mA / 0.1 W 115 V AC 23.9 mA / 0.4 VA 230 V AC 26.9 mA / 0.7 VA Timing circuit Kind of timer Single‑function timer OFF‑delay with auxiliary voltage Time ranges 0.05 s ‑ 100 h 0.05‑1 s, 0.5‑10 s, 5‑100 s, 0.5‑10 min, 5‑100 min, 0.5‑10 h, 5‑100 h Recovery time < 50 ms Repeat accuracy (constant parameters) Dt < ± 0.5 % Accuracy within the rated control supply voltage tolerance Dt < 0.005 % / V Accuracy within the temperature range Dt < 0.06 % / °C Setting accuracy of time delay ± 10 % of full-scale value User interface Indication of operational states Control supply voltage / timing U: green LED Relay status R: yellow LED V: control supply voltage applied W: timing 4 - Electronic timer CT-AHD.12 | Data sheet V: output relay energized Output circuit Kind of output 15-16/18 relay, 1 c/o (SPDT) contact Contact material Cd‑free Rated operational voltage Ue 250 V Minimum switching voltage / Minimum switching current 12 V / 100 mA Maximum switching voltage / Minimum switching current see load limit curve / see load limit curve Rated operational current Ie AC-12 (resistive) at 230 V 6A AC-15 (inductive) at 230 V 3A DC-12 (resistive) at 24 V 6A DC-13 (inductive) at 24 V 2A AC rating (UL 508) utilization category (Control Circuit Rating Code) max. rated operational voltage B 300 300 V AC maximum continuous thermal current at B 300 5A max. making/breaking apparent power at B 300 3600 VA / 360 VA Mechanical lifetime 30 x 106 switching cycles Electrical lifetime AC-12, 230 V, 4 A 0.1 x 106 switching cycles Maximum fuse rating to achieve n/c contact 6 A fast-acting short-circuit protection n/o contact 10 A fast-acting General data MTBF on request Duty time 100 % Dimensions (W x H x D) product dimensions packaging dimensions Weight 17.5 x 70 x 58 mm (0.69 x 2.76 x 2.28 in) 89 x 65 x 20 mm (3.50 x 2.56 x 0.79 in) net weight 0.053 kg (0.117 lb) gross weight 0.065 kg (0.143 lb) Mounting DIN rail (IEC/EN 60715), snap‑on mounting without any tool Mounting position any Minimum distance to other units, normal operation mode Degree of protection horizontal not necessary vertical not necessary housing IP50 terminals IP20 Electrical connection Connecting capacity fine-strand with wire end ferrule 2 x 0.5‑1.5 mm2 / 1 x 0.5‑2.5 mm2 (2 x 20‑16 AWG / 1 x 20‑14 AWG) fine-strand without wire end ferrule 2 x 0.5‑1.5 mm2 / 1 x 0.5‑2.5 mm2 (2 x 20‑16 AWG / 1 x 20‑14 AWG) rigid 2 x 0.5‑1.5 mm2 / 1 x 0.5‑4 mm2 (2 x 20‑16 AWG / 1 x 20‑12 AWG) Stripping length 7 mm (0.28 in) Tightening torque 0.5‑0.8 Nm (4.43-7.08 lb.in) Environmental data Ambient temperature ranges operation storage -20...+60 °C (-4...+140 °F) -40...+85 °C (-40...+185 °F) Climatic class (IEC/EN 60068‑2‑30) 3k3 Relative humidity range 25 % to 85 % Vibration, sinusoidal (IEC/EN 60068‑2‑6) 20 m/s2, 10 cycles, 10...150...10 Hz Shock, half‑sine (IEC/EN 60068‑2‑27) 150 m/s2, 11 ms Data sheet | Electronic timer CT-AHD.12 - 5 Isolation data Rated insulation voltage Ui input circuit / output circuit output circuit 1 / output circuit 2 300 V n/a Rated impulse withstand voltage Uimp between all isolated circuits 4 kV; 1.2/50 μs Power‑frequency withstand voltage between all isolated circuits 2.5 kV, 50 Hz, 60 s (test voltage) Basic insulation (IEC/EN 61140) input circuit / output circuit Protective separation input circuit / output circuit (IEC/EN 61140, EN 50178) 300 V 250 V Pollution degree 3 Overvoltage category III Standards / Directives Standards IEC/EN 61812‑1 Low Voltage Directive 2014/35/EU EMC directive 2014/30/EU RoHS Directive 2011/65/EC Electromagnetic compatibility Interference immunity to IEC/EN 61000‑6‑2 electrostatic discharge IEC/EN 61000-4-2 Level 3 (6 kV / 8 kV) radiated, radio-frequency, IEC/EN 61000-4-3 Level 3 (10 V/m) electrical fast transient / burst IEC/EN 61000-4-4 Level 3 (2 kV / 5 kHz) surge IEC/EN 61000-4-5 Level 3 (2 kV L-L) conducted disturbances, induced by IEC/EN 61000-4-6 Level 3 (10 V) electromagnetic field radio-frequency fields Interference emission high-frequency radiated IEC/EN 61000-6-3 IEC/CISPR 22, Class B EN 55022 high-frequency conducted IEC/CISPR 22, EN 55022 6 - Electronic timer CT-AHD.12 | Data sheet Class B Technical diagrams AC voltage [V] DC voltage [V] Load limit curves AC current [A] DC load (resistive) 1.0 Switching cycles Derating factor F AC load (resistive) DC current [A] 2CDC 252 045 F0207 resistive load 2CDC 252 044 F0207 resistive load 0.9 0.8 0.7 250 V resistive load 0.1 0.2 0.3 0.4 0.5 0.6 0.7 Derating factor F for inductive AC load 0.8 0.9 1.0 cos ϕ Switching current [A] 2CDC 252 123 F0206 0.5 2CDC 252 124 F0206 0.6 Contact lifetime Data sheet | Electronic timer CT-AHD.12 - 7 Dimensions in mm and inches 58 2.28“ 43,4 1.71“ 2CDC 252 131 F0b06 70 2.76“ 0.2“ 5 45 1.77“ 0.69“ 17,5 Further documentation Document title Document type Document number Electronic products and relays Technical catalogue 2CDC 110 004 C02xx CT-D range Instruction manual 1SVC 500 010 M1000 You can find the documentation on the internet at www.abb.com/lowvoltage -> Automation, control and protection -> Electronic relays and controls -> Electronic timers. CAD system files You can find the CAD files for CAD systems at http://abb-control-products.partcommunity.com -> Low Voltage Products & Systems -> Control Products -> Electronic Relays and Controls. 8 - Electronic timer CT-AHD.12 | Data sheet Contact us Document number 2CDC 111 161 D0201 (08.2016) ABB STOTZ-KONTAKT GmbH P. O. Box 10 16 80 69006 Heidelberg, Germany Phone: +49 (0) 6221 7 01-0 Fax: +49 (0) 6221 7 01-13 25 E-mail: info.desto@de.abb.com You can find the address of your local sales organisation on the ABB home page http://www.abb.com/contacts -> Low Voltage Products and Systems Note: We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB AG does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents – in whole or in parts – is forbidden without prior written consent of ABB AG. Copyright© 2016 ABB All rights reserved
1SVR500110R0000. 价格&库存

很抱歉,暂时无法提供与“1SVR500110R0000.”相匹配的价格&库存,您可以联系我们找货

免费人工找货