0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
2TLA020055R0700

2TLA020055R0700

  • 厂商:

    ABB

  • 封装:

  • 描述:

    ABB - JOKAB - 2TLA020055R0700 - Connector, Y Type, Serial, Adam OSSD-Reset / OSSD-Info, 5 Leads

  • 数据手册
  • 价格&库存
2TLA020055R0700 数据手册
Reset buttons Smile Smile reset buttons have compact housings with M12 connectors for easy connection. The reset button contains an integrated white LED, and all buttons are delivered with a kit of colored filters to snap on the top of the button. In this way the color of the button can be chosen after delivery and is also possible to changed later. Several models are available to suit different needs of connection and communication (e.g. OSSD or dynamic signals). The different models also allows a choice of: - local reset connected directly to the sensor, or - global reset connected to the safety control module. Easy to install Space saving Easy to install Space saving Easy to attach to profiles The centered mounting holes makes Smile easy to attach to e.g. aluminum extrusions profiles. Compact housing A compact and appealing housing saves space and makes it easy to place. Speed up installation The housing requires no assembly and the M12 connectors speed up installation and reduce the risk of connection error. Smile, Reset buttons 2TLC172018V0201 Ordering details Smile 11 RO1 Type of contact Connectors Intended use Type Order code 1 NO 1 male M12-5 Most reset applications Smile 11 RA 2TLA030053R0000 1 NO 1 male M12-5 Pluto Safety PLC light button function* Smile 11 RB 2TLA030053R0100 1 NO 1 male M12-5 Orion1 Base Smile 11RO1 2TLA022316R3000 1 NC 1 male M12-5 Orion2 Base and Extended, and Orion3 Extended Smile 11RO2 2TLA022316R3100 1 NC 1 male M12-5 Orion3 Base Smile 11RO3 2TLA022316R3200 1 NO 2 male M12-5 Eden DYN-Reset M12-5 and Eden OSSD-Reset M12-5 Smile 12 RF 2TLA030053R2600 1 NO 2 male M12-8 Eden OSSD-Reset M12-8 Smile 12 RG 2TLA030053R2700 * See Pluto hardware manual for more information about the light button function 2TLC172623F0201 Accessories 2TLC172475F0201 M12-3x Tina 10B 2 Reset buttons I ABB Description Type Order code Y-connector for serial connection of Adam DYN-Reset (with Smile 12 RF between Adam and Y-connector) and/or Adam DYN-Info (loss of info signal). The two models can be mixed. M12-3A 2TLA020055R0000 Y-connector for serial connection of Adam OSSD-Reset M12-8 (with Smile 12 RG between Adam and Y-connector) and/or Adam OSSD-Info M12-8 (loss of info signal) with 8 lead cables. The two models can be mixed. M12-3H 2TLA020055R0800 Y-connector for serial connection of Adam OSSD-Reset M12-8 (with Smile 12 RG between Adam and Y-connector) and/or Adam OSSD-Info M12-8 (loss of info signal) with 5 lead cables. The two models can be mixed. M12-3G 2TLA020055R0700 Y-connector for connection of Smile reset button to Orion. M12-3R 2TLA022316R0000 Adaptation unit of OSSD outputs to ABB Jokab Safety dynamic signal for use with Vital control module or Pluto Safety PLC. Tina 10B has an extra M12 connector for connection of a reset button. Tina 10B 2TLA020054R1300 M12-3A to el-cabinet El-cabinet to M12-3A M12-3A to M12 3A Cables for Smile 12 RF (with Eden DYN/OSSD Reset M12-5) Smile 12 RF to M12-3A Eden Reset M12-5 to Smile 12 RF Ordering information Cables for Smile 12 RF and RG Type Order code Straight M12-5 female connector with 6 m shielded cable M12-C61 2TLA020056R0000 X Straight M12-5 female connector with 10 m shielded cable M12-C101 2TLA020056R1000 X Straight M12-5 female connector with 20 m shieldewd cable M12-C201 2TLA020056R1400 M12-5 male + female connectors with 1 m shielded cable M12-C112 2TLA020056R2000 X X X M12-5 male + female connectors with 3 m shielded cable M12-C312 2TLA020056R2100 X X X M12-5 male + female connectors with 6 m shielded cable M12-C612 2TLA020056R2200 X X X M12-5 male + female connectors with 10 m shielded cable M12-C1012 2TLA020056R2300 X X X M12-5 male + female connectors with 20 m shielded cable M12-C2012 2TLA020056R2400 X X X Straight M12-5 male connector with 6 m shielded cable M12-C62 2TLA020056R0200 X Straight M12-5 male connector with 10 m shielded cable M12-C102 2TLA020056R1200 X Description Type Order code Straight M12-5 female connector with 6 m shielded cable M12-C61 2TLA020056R0000 X Straight M12-5 female connector with 10 m shielded cable M12-C101 2TLA020056R1000 X Straight M12-5 female connector with 20 m shielded cable M12-C201 2TLA020056R1400 M12-5 male + female connectors with 1 m shielded cable M12-C112 2TLA020056R2000 X M12-5 male + female connectors with 3 m shielded cable M12-C312 2TLA020056R2100 X M12-5 male + female connectors with 6 m shielded cable M12-C612 2TLA020056R2200 X M12-5 male + female connectors with 10 m shielded cable M12-C1012 2TLA020056R2300 X M12-5 male + female connectors with 20 m shielded cable M12-C2012 2TLA020056R2400 Straight M12-8 female connector with 6 m shielded cable M12-C63 2TLA020056R3000 X Straight M12-8 female connector with 10 m shielded cable M12-C103 2TLA020056R4000 X Straight M12-8 female connector with 20 m shielded cable M12-C203 2TLA020056R4100 M12-8 male + female connectors with 1 m shielded cable M12-C134 2TLA020056R5000 X X X M12-8 male + female connectors with 3 m shielded cable M12-C334 2TLA020056R5100 X X X Straight M12-5 male connector with 6 m shielded cable M12-C62 2TLA020056R0200 Straight M12-5 male connector with 10 m shielded cable M12-C102 2TLA020056R1200 Straight M12-8 male connector. Cable 8 leads + shield, by meter M12-C04 2TLA020055R1700 M12-3H to el-cabinet El-cabinet to M12-3H M12-3H to M12-3H M12-3G to el-cabinet El-cabinet to M12-3G M12-3G to M12-3G X Smile 12 RG to M12-3G or M12-3H Cables for Smile 12 RG (with Eden DYN/OSSD Reset M12-8) Eden Reset M12-8 to Smile 12 RG Description X X X X X X ABB I Reset buttons 3 M12-3A to el-cabinet El-cabinet to M12-3A M12-3A to M12 3A Tina 10B to M12-3A M12-3R to el-cabinet Smile 11 ROx to M12-3R Tina 10B to el-cabinet Smile 11 ROx to Tina 10B Smile 11 Rx to el-cabinet Cables for Smile 11 Rx and ROx Smile11 Rx to another M12 Ordering information Cables for Smile 11 Rx and ROx Description Type Order code Straight M12-5 female connector with 6 m shielded cable M12-C61 2TLA020056R0000 X X X X Straight M12-5 female connector with 10 m shielded cable M12-C101 2TLA020056R1000 X X X X Straight M12-5 female connector with 20 m shielded cable M12-C201 2TLA020056R1400 X X X M12-5 male + female connectors with 1 m shielded cable M12-C112 2TLA020056R2000 X X X X X M12-5 male + female connectors with 3 m shielded cable M12-C312 2TLA020056R2100 X X X X X M12-5 male + female connectors with 6 m shielded cable M12-C612 2TLA020056R2200 X X X X X M12-5 male + female connectors with 10 m shielded cable M12-C1012 2TLA020056R2300 X X X X X M12-5 male + female connectors with 20 m shielded cable M12-C2012 2TLA020056R2400 X X X X X Straight M12-5 male connector with 6 m shielded cable M12-C62 2TLA020056R0200 X Straight M12-5 male connector with 10 m shielded cable M12-C102 2TLA020056R1200 X X Connection examples Reset to Orion with Tina 10A/C ceiver Orion re R M12-3 Reset to Orion with Tina 10B e part or activ (a) (a) set Smile re M12 5-pole male 1. + 24 VDC 2. OSSD1 3. 0 V 4. OSSD2 5. - Connection of Smile 11 ROx to Orion through M12-3R. For connection to any control module compatible with OSSD outputs. Reset to Eden Serial connection of Eden with individual Smile reset buttons: - Adam OSSD-Reset M12-8 with Smile 12 RG and M12-3G or M12-3H - Adam DYN-Reset with Smile 12 RF and M12-3A 4 Reset buttons I ABB e part or activ ceiver Orion re B Tina 10 set Smile re M12 5-pole male 1. + 24 VDC In 2. 3. 0 V Out 4. 5. Info Connection of Smile 11 ROx to Orion through Tina 10B For connection to Vital control module or Pluto Safety PLC. Technical data Approvals Power supply LED operating voltage LED current consumption Push button operating voltage Push button current Push button rated power Mechanical data Color - Enclosure Color - Push button Material - Housing Material - Contact Size Weight Protection class Connectors Smile 11 RA/-B/-O Connectors Smile 12 RF Connectors Smile 12 RG Mechanical life Switching reliability Environmental data Ambient temperature Humidity range +24 VDC (maximum +33 VDC) 20 mA at +24 VDC, 30 mA at +33 VDC Min: +5 V, max: +35 V Min: 1 mA, max 100 mA Max: 250 mW Yellow White Polyprobylene PP Au 84 x 40 x 36 (L x W x H) + 12 mm for M12 connector (L) Approx. 60 g IP65 M12-5 pole male connector M12-5 pole male and female connectors M12-8 pole male and female connectors 1.000.000 operations at 10 mA/+24 VDC 10 x 10-6 at 5 mA/+24 VDC Environmental data -25...+55°C 35 to 85% (with no icing or condensation) Dimension drawings Smile 11 R Smile 12 R All dimensions in mm ABB I Reset buttons 5 Electrical connections Smile 11 RA Smile 11 RB Smile 12 RF Smile 12 RG SMILE 11RO1 Smile 11 RO2 Smile 11 RO1 1. 2. 3. 4. 5. SMILE 11RO3 Smile 11 RO3 1. 2. 3. 4. 5. 6 Reset buttons I ABB SMILE 11RO2 1. 2. 3. 4. 5. ABB AB Jokab Safety Varlabergsvägen 11 SE-434 39 Kungsbacka Tel. +46 (0) 21-32 50 00 www.abb.com/jokabsafety Note We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents - in whole or in parts – is forbidden without prior written consent of ABB. Copyright© 2016 ABB All rights reserved 2TLC172106L0201 Contact us
2TLA020055R0700 价格&库存

很抱歉,暂时无法提供与“2TLA020055R0700”相匹配的价格&库存,您可以联系我们找货

免费人工找货