PRODUCT-DETAILS
A16-30-10 110V 50Hz / 110-120V 60Hz
A16-30-10 110V 50Hz / 110-120V 60Hz
Contactor
General Information
Extended Product Type
Product ID
EAN
Catalog Description
Long Description
A16-30-10 110V 50Hz / 110-120V 60Hz
1SBL181001R8410
3471522050847
A16-30-10 110V 50Hz / 110-120V 60Hz Contactor
A16 contactors are mainly used for controlling 3-phase motors and generally for
controlling power circuits up to 690 V AC or 220 V DC. The contactors can also be used
for many other applications such as isolation, capacitor switching, lighting. The A...
series 1-stack 3-pole contactors are of the block type design. - Main poles and auxiliary
contact blocks: 3 main poles, 1 built-in auxiliary contact, front and side-mounted addon auxiliary contact blocks - Control circuit: AC operated with laminated magnet
circuit - Accessories: a wide range of accessories is available.
Ordering
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Replacement Product ID
(NEW)
1SBL171001R8410
Popular Downloads
Data Sheet, Technical
Information
Instructions and
Manuals
1SBC100122C0202_Ch02
FPTC407721P0001
A16-30-10 110V 50Hz / 110-120V 60Hz
2
Dimensions
Product Net Width
44 mm
Product Net Depth /
Length
74 mm
Product Net Height
74 mm
Product Net Weight
0.34 kg
Technical
Number of Main
Contacts NO
3
Number of Main
Contacts NC
0
Number of Auxiliary
Contacts NO
1
Number of Auxiliary
Contacts NC
0
Standards
Rated Operational
Voltage
Rated Frequency (f)
Conventional Free-air
Thermal Current (I th )
Devices complying with international standards IEC 947-1 / 947-4-1, and
European standards EN 60 947-1 / 60 947-4-1. Electromagnetic
compatibility (EMC) acc. to amendment A11 to IEC 947-1, EN 60 947-1 and
amendment 2 to IEC 947-4-1
Main Circuit 690 V
Supply Circuit 50 60 Hz
acc. to IEC 60947-4-1, Open Contactors q = 40 °C 30 A
acc. to IEC 60947-5-1, q = 40 °C 16 A
Rated Operational
Current AC-1 (I e )
(690 V) 40 °C 30
(690 V) 55 °C 27
(690 V) 70 °C 23
Rated Operational
Current AC-3 (I e )
(415 V) 55 °C 17 A
(440 V) 55 °C 16 A
(500 V) 55 °C 14 A
(690 V) 55 °C 10 A
(380 / 400 V) 55 °C 17 A
(220 / 230 / 240 V) 55 °C 17
Rated Operational Power
AC-3 (P e )
(415 V) 9 kW
(440 V) 9 kW
(500 V) 9 kW
(690 V) 9 kW
(380 / 400 V) 7.5 kW
(220 / 230 / 240 V) 4 kW
Rated Operational Power
AC-6b (P e )
(230 / 240 V) 40 °C, 50 / 60 Hz 7.5 kvar
(230 / 240 V) 55 °C, 50 / 60 Hz 7.5 kvar
(230 / 240 V) 70 °C, 50 / 60 Hz 6 kvar
(400 / 415 V) 40 °C, 50 / 60 Hz 12.5 kvar
(400 / 415 V) 70 °C, 50 / 60 Hz 10 kvar
(400 / 415 V) 55 °C, 50 / 60 Hz 12.5 kvar
(440 V) 40 °C, 50 / 60 Hz 14 kvar
(440 V) 55 °C, 50 / 60 Hz 14 kvar
(440 V) 70 °C, 50 / 60 Hz 10.5 kvar
(500 / 550 V), 40 °C, 50 / 60 Hz 15.5 kvar
(500 / 550 V) 55 °C, 50 / 60 Hz 15.5 kvar
(500 / 550 V) 70 °C, 50 / 60 Hz 12 kvar
(690 V) 40 °C, 50 / 60 Hz 21.5 kvar
(690 V) 55 °C, 50 / 60 Hz 21.5 kvar
(690 V) 70 °C, 50 / 60 Hz 16.5 kvar
Rated Breaking Capacity
AC-3 acc. to IEC 60947-41
8 x Ie AC-3
Rated Making Capacity
AC-3 acc. to IEC 60947-41
10 x Ie AC-3
Rated Operational
Current AC-15 (I e )
(500 V) 2 A
(690 V) 2 A
(24 / 127 V) 6 A
(220 / 240 V) 4 A
A16-30-10 110V 50Hz / 110-120V 60Hz
3
(380 / 400 V) 3 A
Short-Circuit Protective
Devices
Auxiliary Circuit - gG Type Fuses 10 A
gG Type Fuses 32 A
Maximum Breaking
Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 90 A
Maximum Electrical
Switching Frequency
(AC-1) 600 cycles per hour
(AC-2 / AC-4) 300 cycles per hour
(AC-3) 1200 cycles per hour
(24 V) 6 / 144 A
(48 V) 2.8 / 134 A
(72 V) 2 / 144 A
(125 V) 1.1 / 138 A
(250 V) 0.55 / 138 A
Rated Operational
Current DC-13 (I e )
Rated Insulation Voltage
(U i )
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
acc. to IEC 60947-5-1 and VDE 0110 (Gr. C) 690 V
acc. to UL/CSA 600 V
Rated Impulse
Withstand Voltage (U imp
)
8 kV
Mechanical Durability
10 million
Maximum Mechanical
Switching Frequency
3600 cycles per hour
Rated Control Circuit
Voltage (U c )
50 Hz 110 V
60 Hz 110 ... 120 V
Coil Consumption
Operate Time
Average Holding Value 50 / 60 Hz 8 2 V·A
Average Pull-in Value 50 Hz 74 V·A
Average Pull-in Value 60 Hz 70 V·A
Between Coil De-energization and NO Contact Opening 4 ... 11 ms
Between Coil Energization and NO Contact Closing 10 ... 26 ms
Connecting Capacity
Main Circuit
Flexible with Cable End 0.75 ... 2.5 mm²
Rigid Cable 1 ... 4 mm²
Connecting Capacity
Auxiliary Circuit
Flexible with Cable End 0.75 ... 2.5 mm²
Rigid Cable 1 ... 4 mm²
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
Connecting Terminals
(delivered in open
position) Main Poles
M 3.5 (+,-) pozidriv 2 screws with cable clamp
Terminal Type
Screw Terminals
Environmental
Ambient Air
Temperature
Climatic Withstand
Close to Contactor Fitted with Thermal O/L Relay -25 ... +55 °C
Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... +55 °C
Close to Contactor without Thermal O/L Relay (Uc) -40 ... +70 °C
Close to Contactor for Storage -60 ... +80 °C
acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
Maximum Operating
Altitude Permissible
3000 m
Resistance to Shock acc.
to IEC 60068-2-27
Closed, Shock Direction: B1 10 K40
Open, Shock Direction: B1 5 K40
Shock Direction: A 20 K40
Shock Direction: B2 15 K40
Shock Direction: C1 20 K40
Shock Direction: C2 20 K40
RoHS Status
Following EU Directive 2011/65/EU
Certificates and Declarations (Document Number)
BV Certificate
CB Certificate
BV_2634H07559E0
CB_CN44759
CCC Certificate
CCC_2018010304059156
CCC_2004010309130463
CQC Certificate
CQC2013010304615753
CQC2018010304059156
A16-30-10 110V 50Hz / 110-120V 60Hz
4
CQC2004010309130463
CSA Certificate
Declaration of
Conformity - CCC
CSA_1041746
2020980304001607
2020980304001616
2020980304001229
Declaration of
Conformity - CE
1SBD250801U1000
DNV Certificate
DNV-GL_TAE00000TX
DNV GL Certificate
EAC Certificate
DNV-GL_TAE00000TX
EAC_RU C-FR ME77 B03599
Environmental
Information
1SBD250003E1004
Instructions and
Manuals
FPTC407721P0001
LOVAG Certificate
LR Certificate
RINA Certificate
RMRS Certificate
RoHS Information
UL Certificate
UL Listing Card
LOVAG_FR97039
LRS_9830011E4
RINA_ELE172319XG001
RMRS_0507015250
1SBD250801U1000
UL_20160205-E312527-10-2
UL_E312527
Container Information
Package Level 1 Units
1 piece
Package Level 1 Width
78 mm
Package Level 1 Depth /
Length
76 mm
Package Level 1 Height
47 mm
Package Level 1 Gross
Weight
0.34 kg
Package Level 1 EAN
3471522050847
Package Level 2 Units
box 63 piece
Package Level 2 Width
300 mm
Package Level 2 Depth /
Length
245 mm
Package Level 2 Height
308 mm
Package Level 2 Gross
Weight
21.42 kg
Package Level 3 Units
1220 piece
Classifications
Object Classification
Code
Q
ETIM 4
EC000066 - Magnet contactor, AC-switching
ETIM 5
EC000066 - Magnet contactor, AC-switching
ETIM 6
EC000066 - Power contactor, AC switching
ETIM 7
EC000066 - Power contactor, AC switching
UNSPSC
E-Number (Finland)
39121529
3709140
A16-30-10 110V 50Hz / 110-120V 60Hz
Categories
Low Voltage Products and Systems → Control Products → Contactors → Block Contactors
5
A16-30-10-110V-50HZ 价格&库存
很抱歉,暂时无法提供与“A16-30-10-110V-50HZ”相匹配的价格&库存,您可以联系我们找货
免费人工找货