0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
ACS150-01E-07A5-2

ACS150-01E-07A5-2

  • 厂商:

    ABB

  • 封装:

  • 描述:

    ABB - ACS150-01E-07A5-2 - Inverter Drive, Micro, ACS150 Series, Single Phase, 1.5 kW, 200 V to 240 V

  • 数据手册
  • 价格&库存
ACS150-01E-07A5-2 数据手册
Low voltage AC drives ABB micro drives ACS150 0.37 to 4 kW/0.5 to 5 hp Catalog Introduction to ACS150 ABB micro drives ABB micro drives are designed to be incorporated into a wide variety of machines such as mixers, conveyors, fans or pumps or anywhere where a fixed speed motor needs to go variable speed motor. The ABB micro drives meet the requirements of OEMs, machinery builders and panel builders. These drives are widely available through the ABB distribution network. The drives are easy to select and provide a range of built-in features as standard including PID control, brake chopper, fixed keypad and speed control potentiometer. Highlights – Worldwide availability through logistical distributors – User-friendly LCD control panel and integrated potentiometer – Flexible mounting alternatives – PID control – Integrated EMC filter – Built-in brake chopper – FlashDrop tool for fast drive commissioning Feature Advantage Benefit Worldwide availability and service Drives are available worldwide and permanently stocked in four Fast and reliable delivery with dedicated regions. support to any country in the world. Dedicated global service and support network that is one of the widest in the industry. User-friendly LCD control panel and Clear alphanumeric display. Easy setup and use. integrated potentiometer Flexible mounting alternatives Time savings due to quick setup and simple configuration. Screw or DIN rail mounting, sideways or side-by-side. One drive type can be used in various designs, saving installation costs and time. Integrated EMC filter High electromagnetic compatibility. Low EMC emissions in selected environments. Built-in brake chopper as standard No need for an external brake chopper. Space savings, reduced installation cost. FlashDrop tool Faster and easier drive setup and commissioning for volume Fast, safe and trouble-free parameter setting manufacturing and maintenance. The FlashDrop tool enables without the need to power-up the drive. both downloading and uploading drive parameters. Patented. Varies the drive’s performance according to the need of the Enhances production output, stability and application. accuracy. Board coating protects the electronics from hazards including Reduces maintenance due to good protection static discharge and airborne contaminates, including moisture. of electronics components. PID control Coated boards 2 ABB micro drives ACS150 | Catalog Easily integrated drives for a wide range of applications ABB micro drives bring speed control benefits to a wide variety of applications. In mixing applications the drive provides high starting torque which benefits the start of the mixing operation. The silent operation mode adjusts the switching frequency of the drive to a higher level after the high-torque start, resulting in lower audible noise. The FlashDrop tool provides a quick and safe way to configure multiple drives for identical mixer applications. In conveyors the belt speed can be controlled using a drive and a motor. Production lines often have multiple stages, including conveyors, which need to be efficiently linked with each other to provide high production output. A drive provides smooth start and stop of the conveyor, thereby reducing mechanical stress and lowering maintenance costs. A heat pump system consists of an indoor unit with fan and an outdoor unit with a compressor and a blower. The heat pump cools indoor environment by gathering heat from the air, and transferring the heat outside. The outdoor unit uses the compressor and the blower to dissipate the heat. The cooled air is blown indoors by fans located in the indoor unit. Drive allows the user to variably control the cooling power based on customer request. AC drives optimizes systems’ energy efficiency and smoothens system operation. Fans are used for process cooling and ventilation in industrial, commercial and domestic environments. Using a drive to control air flow enables energy savings compared to mechanical flow control methods. An ABB drive has integrated PID control which provides optimal air flow by adjusting the fan speed based on a given reference value. Compact size and various mounting methods enable flexible system design. Catalog | ABB micro drives ACS150 3 Ratings, types and dimensions Type designation In column 4 on the right is the unique reference number that clearly indentifies your drive by power rating and frame size. Once you have selected the type designation, the frame size (column 5) can be used to determine the drives dimensions, shown below. Voltages ACS150 is available in two voltage ranges: Ratings Type designation PN PN I2N kW hp A Frame size 1-phase AC supply, 200 to 240 V 0.37 0.5 2.4 ACS150-01X-02A4-2 R0 0.75 1 4.7 ACS150-01X-04A7-2 R1 1.1 1.5 6.7 ACS150-01X-06A7-2 R1 1.5 2 7.5 ACS150-01X-07A5-2 R2 2.2 3 9.8 ACS150-01X-09A8-2 R2 3-phase AC supply, 200 to 240 V 2 = 200 to 240 V 4 = 380 to 480 V Insert either “2” or “4”, depending on your chosen voltage, into the type designation shown on the right. 0.37 0.5 2.4 ACS150-03X-02A4-2 R0 0.55 0.75 3.5 ACS150-03X-03A5-2 R0 0.75 1 4.7 ACS150-03X-04A7-2 R1 1.1 1.5 6.7 ACS150-03X-06A7-2 R1 1.5 2 7.5 ACS150-03X-07A5-2 R1 2.2 3 9.8 ACS150-03X-09A8-2 R2 3-phase AC supply, 380 to 480 V Construction “01X” and “03X” within the type designation varies depending on the drive phase and EMC filtering. Choose below the one you need. 01 03 E U = = = = 1-phase 3-phase EMC filter connected, 50 Hz frequency EMC filter disconnected, 60 Hz frequency (In case the filter is required it can easily be connected.) 0.37 0.5 1.2 ACS150-03X-01A2-4 R0 0.55 0.75 1.9 ACS150-03X-01A9-4 R0 0.75 1 2.4 ACS150-03X-02A4-4 R1 1.1 1.5 3.3 ACS150-03X-03A3-4 R1 1.5 2 4.1 ACS150-03X-04A1-4 R1 2.2 3 5.6 ACS150-03X-05A6-4 R1 3 4 7.3 ACS150-03X-07A3-4 R1 4 5 8.8 ACS150-03X-08A8-4 R1 X within the type code stands for E or U. Cabinet-mounted drives (UL open) Frame IP20 UL open size H1 H2 H3 W D Weight R0 mm 169 mm 202 mm 239 mm 70 mm 142 kg 1.1 R1 169 202 239 70 142 1.3 R2 169 202 239 105 142 1.5 H1 H2 H3 W D = = = = = H1 H2 H3 Height without fastenings and clamping plate. Height with fastenings but without clamping plate. Height with fastenings and clamping plate. Width Depth D W Wall-mounted drives (NEMA 1) Frame NEMA 1 size H4 H5 W D Weight R0 mm 257 mm 280 mm 70 mm 142 kg 1.5 R1 257 280 70 142 1.7 R2 257 282 105 142 1.9 H4 H5 W D = = = = Height with fastenings and NEMA 1 connection box. Height with fastenings, NEMA 1 connection box and hood. Width Depth 4 ABB micro drives ACS150 | Catalog H4 H5 D W Technical data Mains connection Voltage and power range Frequency Programmable control connections 1-phase, 200 to 240 V ± 10% 0.37 to 2.2 kW (0.5 to 3 hp) 3-phase, 200 to 240 V ± 10% 0.37 to 2.2 kW (0.5 to 3 hp) 3-phase, 380 to 480 V ± 10% 0.37 to 4 kW (0.5 to 5 hp) One analog input Voltage signal Current signal Potentiometer reference value Resolution Accuracy 0 (2) to 10 V, R in > 312 kΩ 0 (4) to 20 mA, Rin = 100 Ω 10 V ± 1% max. 10 mA, R < 10 kΩ 0.1% ± 2% 48 to 63 Hz Auxiliary voltage 24 V DC ± 10%, max. 200 mA Five digital inputs 12 to 24 V DC with internal or external supply, PNP and NPN, pulse train 0 to 16 kHz Input impedance 2.4 kΩ One relay output Type Maximum switching voltage Maximum switching current Maximum continuous current NO + NC 250 V AC/30 V DC 0.5 A/30 V DC; 5 A/230 V AC 2 A rms Motor connection Voltage 3-phase, from 0 to U supply Frequency 0 to 500 Hz Continuous loading Rated output current I 2N capability (constant torque at a max. ambient temperature of 40 ºC) Overload capability (at a max. ambient temperature of 40 ºC) At heavy duty use 1.5 x I2N for 1 minute every 10 minutes At start 1.8 x I2N for 2 s Switching frequency Default Selectable 4 kHz 4 to 16 kHz with 4 kHz steps Acceleration time 0.1 to 1800 s Deceleration time 0.1 to 1800 s Braking Built-in brake chopper as standard Motor control method Scalar U/f Product compliance Low voltage Directive 2006/95/EC with supplements Machinery Directive 2006/42/EC EMC Directive 2004/108/EC with supplements Quality assurance system ISO 9001 Environmental system ISO 14001 UL, cUL, CE, C-Tick and GOST R approvals RoHS compliant Environmental limits Ambient temperature Altitude Output current -10 to 40 ºC (14 to 104 ºF), no frost allowed, 50 ºC (122 ºF) with 10% derating Rated current available at 0 to 1000 m (0 to 3281 ft) reduced by 1% per 100 m (328 ft) over 1000 to 2000 m (3281 to 6562 ft) Relative humidity Lower than 95% (without condensation) Degree of protection IP20/Optional NEMA 1 enclosure Enclosure colour NCS 1502-Y, RAL 9002, PMS 420 C Contamination levels IEC 721-3-3 No conductive dust allowed Class 1C2 (chemical gases) Class 1S2 (solid particles) Class 2C2 (chemical gases) Class 2S2 (solid particles) Class 3C2 (chemical gases) Class 3S2 (solid particles) Transportation Storage Operation Chokes AC input chokes External option. For reducing THD in partial loads and to comply with EN 61000-3-2. AC output chokes External option. To achieve longer motor cables. Catalog | ABB micro drives ACS150 5 Control connections and interfaces Application macros Application macros are preprogrammed parameter sets. When starting up the drive, the user typically selects one of the macros that is best suited for the application. The diagram below gives an overview of ACS150 control connections and shows the default I/O connections for the ABB standard macro. Removable clip for brand labeling Integrated interface ABB micro drives have six standard macros: – – – – – – FlashDrop connection EMC filter grounding screw (EMC) ABB standard macro 3-wire macro Alternate macro Motor potentiometer macro Hand/auto macro PID control macro Integrated potentiometer Varistor grounding screw (VAR) In addition to the standard macros the user can create three user macros. The user macro allows the user to save the parameter settings for later use. I/O connections Input, brake resistor and motor connections Analog input signal selector (U/I) Typical I/O connections ACS150 Screen Analog input 0 to 10 V Reference voltage +10 V DC, max. 10 mA Aux. voltage output +24 V DC, max. 200 mA Potentiometer SCR SI AI I GND U AI +10 V COM +24 V NC GND NO COM 0 - 20 mA Ground the cable screen on the sourcing end +24 V start/ stop const. speed 1 Relay output 250 V AC / 30 V DC / 6 A DI configuration PNP connected (source) with external power supply DI2 DI3 DI4 DI5 can also be used as a frequency input EMC VAR DI5 EMC filter grounding screw Varistor grounding screw 6 3-phase power supply, 200 to 480 V AC R < 10 kΩ PE U1 V1 W1 PE L1 L2 L3 Input choke EMC filter U ROCOM RONC RONO ACS150 FlashDrop I 0V DI1 PROGRAMMABLE DIGITAL INPUTS fwd/ rev SCR AI GND +10 V +24 V GND DCOM DI1 DI2 DI3 DI4 DI5 Brake chopper BRK+ BRK- M 3~ Output choke AC motor ramp pair sel. start/ const. fwd/ stop speed rev 1 DI configuration NPN connected (sink) t° 6 ABB micro drives ACS150 | Catalog U2 V2 W2 Brake resistor SCR AI GND +10 V +24 V GND DCOM DI1 DI2 DI3 DI4 DI5 ROCOM RONC RONO I U Cooling and fuses Cooling ACS150 is fitted with cooling fans as standard. The cooling air must be free from corrosive substances and must not be above the maximum ambient temperature of 40 °C (50 °C with derating). For more specific limits see the Technical data Environmental limits in this catalog. Fuses Standard fuses can be used with ABB micro drives. For input fuse connections see table below. Cooling air flow Selection table Type designation Frame Heat dissipation Type designation Air flow Frame IEC fuses size size [W] BTU/hr 3 m /h 3 ft /min 1-phase AC supply, 200 to 240 V [A] 1-phase AC supply, 200 to 240 V UL fuses Fuse ) type* [A] Fuse ) type * ACS150-01X-02A4-2 R0 25 85 -* ) -* ) ACS150-01X-02A4-2 R0 10 gG 10 UL class T ACS150-01X-04A7-2 R1 46 157 24 14 ACS150-01X-04A7-2 R1 16 gG 20 UL class T ACS150-01X-06A7-2 R1 71 242 24 14 ACS150-01X-06A7-2 R1 20 gG 25 UL class T ACS150-01X-07A5-2 R2 73 249 21 12 ACS150-01X-07A5-2 R2 25 gG 30 UL class T ACS150-01X-09A8-2 R2 96 328 21 12 ACS150-01X-09A8-2 R2 35 gG 35 UL class T 3-phase AC supply, 200 to 240 V 3-phase AC supply, 200 to 240 V ) ) -* ) -* ACS150-03X-02A4-2 R0 10 gG 10 UL class T 106 -* ) -* ACS150-03X-03A5-2 R0 10 gG 10 UL class T 38 130 24 14 ACS150-03X-04A7-2 R1 10 gG 15 UL class T R1 60 205 24 14 ACS150-03X-06A7-2 R1 16 gG 15 UL class T ACS150-03X-07A5-2 R1 62 212 21 12 ACS150-03X-07A5-2 R1 16 gG 15 UL class T ACS150-03X-09A8-2 R2 83 283 21 12 ACS150-03X-09A8-2 R2 16 gG 20 UL class T ACS150-03X-02A4-2 R0 19 65 ACS150-03X-03A5-2 R0 31 ACS150-03X-04A7-2 R1 ACS150-03X-06A7-2 3-phase AC supply, 380 to 480 V 3-phase AC supply, 380 to 480 V ) ACS150-03X-01A2-4 R0 11 38 ACS150-03X-01A9-4 R0 16 55 -* ) -* ACS150-03X-02A4-4 R1 21 72 13 ACS150-03X-03A3-4 R1 31 106 ACS150-03X-04A1-4 R1 40 ACS150-03X-05A6-4 R1 ACS150-03X-07A3-4 ACS150-03X-08A8-4 ) -* ) -* ACS150-03X-01A2-4 R0 10 gG 10 UL class T ACS150-03X-01A9-4 R0 10 gG 10 UL class T 8 ACS150-03X-02A4-4 R1 10 gG 10 UL class T 13 8 ACS150-03X-03A3-4 R1 10 gG 10 UL class T 137 13 8 ACS150-03X-04A1-4 R1 16 gG 15 UL class T 61 208 19 11 ACS150-03X-05A6-4 R1 16 gG 15 UL class T R1 74 253 24 14 ACS150-03X-07A3-4 R1 16 gG 20 UL class T R1 94 321 24 14 ACS150-03X-08A8-4 R1 20 gG 25 UL class T X within the type code stands for E or U. X within the type code stands for E or U. *) Frame size R0 with free convection cooling. *) According to IEC-60269 standard. Free space requirements Enclosure type Space above Space below Space on left/right All frame sizes mm 75 mm 0 mm 75 Catalog | ABB micro drives ACS150 7 Options FlashDrop tool FlashDrop is a powerful palm sized tool for fast and easy parameter selecting and setting. It gives the possibility to hide selected parameters to protect the machine. Only the parameters needed in the application are shown. The tool can copy parameters between two drives or between a PC and a drive. All the above can be done without a power connection to the drive – in fact, it is not even necessary to unpack the drive. DrivePM DrivePM (Drive parameter manager) is a tool to create, edit and copy parameter sets for FlashDrop. For each parameter/ group the user has a possibility to hide it, which means that the drive user does not see the parameter/group at all. Protection class NEMA 1 The NEMA 1 kit includes a connection box for finger protection, conduit tube installation, and a hood for protection against dirt and dust. Brake resistors ACS150 is delivered with an integrated brake chopper as standard. Therefore no additional space or installation time is needed, The brake resistor is selected using the table below. For more information about the selection of brake resistors, see the ACS150 user’s manual. Brake chopper limits and resistor selection table Type R min PBRmax Selection table by resistor type designation DrivePM requirements – Windows 2000/XP/Vista/Windows 7 – Free serial port from a PC FlashDrop package includes – FlashDrop tool – DrivePM software on a CD-rom – User’s manual in pdf-format on the previous CD-rom – Cable for connection between the PC and FlashDrop – Battery charger 160 ACS150[ohm] [kW] CBR-V 210 Braking 460 [hp] time 1) [s] 1-phase AC supply, 200 to 240 V 01X-02A4-2 70 0.37 0.5 90 01X-04A7-2 40 0.75 1 45 01X-06A7-2 40 1.1 1.5 28 01X-07A5-2 30 1.5 2 19 01X-09A8-2 30 2.2 3 14 3-phase AC supply, 200 to 240 V 03X-02A4-2 70 0.37 0.5 90 03X-03A5-2 70 0.55 0.75 60 03X-04A7-2 40 0.75 1 42 03X-06A7-2 40 1.1 1.5 29 03X-07A5-2 30 1.5 2 19 03X-09A8-2 30 2.2 3 14 3-phase AC supply, 380 to 480 V 03X-01A2-4 200 0.37 0.5 90 03X-01A9-4 175 0.55 0.75 90 03X-02A4-4 165 0.75 1 60 03X-03A3-4 150 1.1 1.5 37 03X-04A1-4 130 1.5 2 27 03X-05A6-4 100 2.2 3 17 03X-07A3-4 70 3 4 29 03X-08A8-4 70 4 5 20 X within the type code stands for E or U. 1) Braking time = Maximum allowed braking time in seconds at PBRmax every 120 seconds, at 40 °C ambient temperature 8 ABB micro drives ACS150 | Catalog Ratings by resistor type CBR-V 160 CBR-V 210 CBR-V 460 Nominal power [W] 280 360 790 Resistance [ohm] 70 200 80 Options External A separate order line and type designation is required for any of these external options. Input chokes Input choke smooths the wave shape of the mains current and reduces total harmonic distortion (THD). Together with the input choke, the ACS150 is designed to fulfill the requirements of the harmonics standard EN/IEC 61000-3-12. In addition, the input choke provides improved protection against mains voltage transients. Type Frame Input I 1N I 1N designation size without choke [A] [A] [A] [mH] choke ACS150- Output chokes Output choke decreases du/dt on the output and filters current spikes caused by voltage spikes. With an output choke it is possible to increase the motor cable length which could be otherwise limited due to a temperature increase resulting from current spikes and electromagnetic performance. Type Frame with designation size choke ACS150- I TH L 1-phase AC supply, 200 to 240 V Output choke Cable length [m] 1-phase AC supply, 200 to 240 V 01X-02A4-2 R0 CHK-A1 6.1 4.5 5 8.0 01X-02A4-2 R0 ACS-CHK-B3 01X-04A7-2 R1 CHK-B1 11.4 8.1 10 2.8 01X-04A7-2 R1 ACS-CHK-B3 100 01X-06A7-2 R1 CHK-C1 16.1 11 16 1.2 01X-06A7-2 R1 ACS-CHK-C3 100 01X-07A5-2 R2 CHK-C1 16.8 12 16 1.2 01X-07A5-2 R2 ACS-CHK-C3 100 01X-09A8-2 R2 CHK-D1 21 15 25 1.0 01X-09A8-2 R2 ACS-CHK-C3 100 3-phase AC supply, 200 to 240 60 3-phase AC supply, 200 to 240 V 03X-02A4-2 R0 CHK-01 4.3 2.2 4.2 6.4 03X-02A4-2 R0 ACS-CHK-B3 60 03X-03A5-2 R0 CHK-02 6.1 3.6 7.6 4.6 03X-03A5-2 R0 ACS-CHK-B3 60 03X-04A7-2 R1 CHK-03 7.6 4.8 13 2.7 03X-04A7-2 R1 ACS-CHK-B3 100 03X-06A7-2 R1 CHK-03 11.8 7.2 13 2.7 03X-06A7-2 R1 ACS-CHK-C3 100 03X-07A5-2 R1 CHK-04 12 8.2 22 1.5 03X-07A5-2 R1 ACS-CHK-C3 100 03X-09A8-2 R2 CHK-04 14.3 11 22 1.5 03X-09A8-2 R2 ACS-CHK-C3 100 3-phase AC supply, 380 to 480 V 3-phase AC supply, 380 to 480 V 03X-01A2-4 R0 CHK-01 2.2 1.1 4.2 6.4 03X-01A2-4 R0 ACS-CHK-B3 60 03X-01A9-4 R0 CHK-01 3.6 1.8 4.2 6.4 03X-01A9-4 R0 ACS-CHK-B3 60 03X-02A4-4 R1 CHK-01 4.1 2.3 4.2 6.4 03X-02A4-4 R1 ACS-CHK-B3 100 03X-03A3-4 R1 CHK-01 6 3.1 4.2 6.4 03X-03A3-4 R1 ACS-CHK-B3 100 03X-04A1-4 R1 CHK-02 6.9 3.5 7.6 4.6 03X-04A1-4 R1 ACS-CHK-C3 100 03X-05A6-4 R1 CHK-02 9.6 4.8 7.6 4.6 03X-05A6-4 R1 ACS-CHK-C3 100 03X-07A3-4 R1 CHK-02 11.6 6.1 7.6 4.6 03X-07A3-4 R1 NOCH-0016-6x 100 03X-08A8-4 R1 CHK-03 13.6 7.7 13 2.7 03X-08A8-4 R1 NOCH-0016-6x 100 I1N = Nominal input current ITH = Nominal choke thermal current L = Choke inductance Catalog | ABB micro drives ACS150 9 Options External A separate order line and type designation is required for any of these external options. EMC filters The ACS150’s internal EMC filter is designed to meet category C3 requirements of EN/IEC 61800-3 standard. External EMC filters are used to enhance the drives electromagnetic performance in conjunction with its internal filtering. Maximum motor cable length depends on required electromagnetic performance, according to the table below. Type Frame designation size Low leakage current filters Low leakage current filters are ideal for installations where residual current devices (RCD) are required and leakage current needs to be below 30 mA. Filter Cable length1) with Cable length1) Type Frame type external EMC filter without external designation size ACS150- EMC filter Filter type Cable length1) with LRFI filter C2 ACS150- [m] C1 C2 C3 C3 C4 [m] [m] [m] [m] [m] Low leakage current filters, 3-phase AC supply, 400 V R0 R0 R1 LRFI-31 LRFI-31 LRFI-31 10 10 10 01X-02A4-2 R0 RFI-11 10 30 - 30 30 01X-04A7-2 R1 RFI-12 10 30 50 30 50 03X-01A2-4 03X-01A9-4 03X-02A4-4 01X-06A7-2 R1 RFI-12 10 30 50 30 50 03X-03A3-4 R1 LRFI-31 10 50 03X-04A1-4 R1 LRFI-31 10 50 03X-05A6-4 R1 LRFI-31 10 03X-07A3-4 R1 LRFI-32 10 03X-08A8-4 R1 LRFI-32 10 1-phase AC supply, 200 to 240 V 01X-07A5-2 01X-09A8-2 R2 R2 RFI-13 RFI-13 10 10 30 30 50 50 30 30 3-phase AC supply, 200 to 240 V 03X-02A4-2 R0 RFI-32 10 30 - 30 30 03X-03A5-2 R0 RFI-32 10 30 - 30 30 03X-04A7-2 R1 RFI-32 10 30 50 30 50 03X-06A7-2 R1 RFI-32 10 30 50 30 50 03X-07A5-2 R1 RFI-32 10 30 50 30 50 03X-09A8-2 R2 RFI-32 10 30 50 30 50 1) Internal EMC filter must be disconnected by removing the EMC screw from the drive. EMC standards in general EN 61800-3 EN 55011, product family EN 61800-3/A11 (2000), 03X-01A2-4 R0 RFI-32 30 30 - 30 30 (2004), standard for industrial, 03X-01A9-4 R0 RFI-32 30 30 - 30 30 product scientific and medical 03X-02A4-4 R1 RFI-32 50 50 50 30 50 standard (ISM) equipment 03X-03A3-4 R1 RFI-32 50 50 50 30 50 Category C1 Group 1 1 st environment, 03X-04A1-4 R1 RFI-32 50 50 50 30 50 03X-05A6-4 R1 RFI-32 50 50 50 30 50 Class B unrestricted distribution 03X-07A3-4 R1 RFI-32 50 50 50 30 50 Category C2 Group 1 1 st environment, 03X-08A8-4 R1 RFI-32 50 50 50 30 50 Category C3 Class A Group 2 restricted distribution 2 nd environment, Category C4 Class A Not applicable unrestricted distribution 2nd environment, 3-phase AC supply, 380 to 480 V 1) Internal EMC filter must be connected with the EMC screw in the drive. When the filter is not connected the C4 maximum cable lengths are allowed to be used. 10 ABB micro drives ACS150 | Catalog product standard restricted distribution Expertise at every stage of the value chain Prepurchase Order and delivery Installation and commissioning Operation and maintenance Upgrade and retrofit Replacement and recycling Training and learning Technical support Contracts Whether you operate in industry, commerce or a utility your aims remain the same: to keep your motor-driven applications running consistently and efficiently. The life cycle services for ABB drives can help you achieve these aims by maximizing the uptime of your process while ensuring the optimum lifetime of ABB drives in a predictable, safe and low-cost manner. The life cycle services for ABB drives span the entire value chain, from the moment you make the first enquiry about a drive through to its disposal and recycling. Throughout the value chain, ABB provides training and learning, technical support and contracts. All of this is supported by one of the most extensive global drive sales and service networks. Secure uptime throughout the drive life cycle ABB follows a four-phase model for the life cycle management of its drives. The life cycle phases are active, classic, limited and obsolete. Within each phase, every drive series has a defined set of services. The four-phase drive life cycle management model provides you with a transparent method for managing your investment in drives. In each phase, you clearly see what life cycle services are available, and more importantly, what services are not available. Decisions on upgrading, retrofitting or replacing drives can be made with confidence. ABB drive life cycle management model Active The drive, with complete life cycle services, is available for purchase. Classic The drive, with complete life cycle services, is available for plant extensions. Limited Spare parts, maintenance and repair services are available as long as materials can be obtained. Obsolete ABB cannot guarantee availability of life cycle services for technical reasons or within reasonable cost. Complete life cycle services Limited life cycle services To ensure the availability of complete life cycle services, a drive must be in the active or classic phase. A drive can be kept in the active or classic phase by upgrading, retrofitting or replacing. Caution! A drive entering the limited or obsolete phase has limited repair options. This may result in unpredictable process downtime. To avoid this possibility, the drive should be kept in the active or classic phase. Catalog | ABB micro drives ACS150 11 For more information please contact your local ABB representative or visit: www.abb.com/drives www.abb.com/drivespartners © Copyright 2012 ABB. All rights reserved. Specifications subject to change without notice. 3AFE68596114 REV F EN 24.10.2012 Contact us
ACS150-01E-07A5-2 价格&库存

很抱歉,暂时无法提供与“ACS150-01E-07A5-2”相匹配的价格&库存,您可以联系我们找货

免费人工找货