0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
AF12-30-10-12

AF12-30-10-12

  • 厂商:

    ABB

  • 封装:

  • 描述:

    ABB - AF12-30-10-12 - Contactor, 12.5 A, DIN Rail, 130 V, 3PST-NO, 3 Pole, 5.5 kW

  • 数据手册
  • 价格&库存
AF12-30-10-12 数据手册
AF12-30-10-12 General Information Extended Product Type: Product ID: EAN: Catalog Description: Long Description: AF12-30-10-12 1SBL157001R1210 3471523110328 AF12-30-10-12 48-130V50/60HZ-DC Contactor AF12 contactors are used for controlling power circuits up to 690 V AC and 220 V DC. They are mainly used for controlling 3-phase motors, non-inductive or slightly inductive loads. AF... contactors include an electronic coil interface accepting a wide control voltage Uc min. ... Uc max. Only four coils cover control voltages between 24...500 V 50/60 Hz or 20...500 V DC. AF contactors can manage large control voltage variations. One coil can be used for different control voltages used worldwide without any coil change. AF contactors have built-in surge protection and do not require additional surge suppressors. The AF... series 1-stack 3-pole contactors are of the block type design. - Main poles and auxiliary contact blocks: 3 main poles, 1 built-in auxiliary contact, front and side-mounted add-on auxiliary contact blocks (mechanically-linked auxiliary contacts compliant with Annex L of IEC 60947-5-1. N.C. mirror contacts compliant with Annex F of IEC 60947-4-1) - Control circuit: AC or DC operated - Accessories: a wide range of accessories is available. Categories Products » Low Voltage Products and Systems » Control Products » Contactors » Block Contactors Ordering Minimum Order Quantity: Customs Tariff Number: EAN: 1 piece 85369085 3471523110328 Dimensions Product Net Depth: Product Net Height: Product Net Weight: Product Net Width: 77 mm 86 mm 0.270 kg 45 mm Container Information Package Level 1 Width: Package Level 1 Length: Package Level 1 Height: Package Level 1 Gross Weight: Package Level 1 EAN: Package Level 2 Units: Package Level 2 Width: Package Level 2 Length: Package Level 2 Height: Package Level 3 Units: Package Level 1 Units: 87 mm 79 mm 47 mm 0.27 kg 3471523110328 54 piece 250 mm 300 mm 315 mm 1296 piece 1 piece Technical Number of Main Contacts NC: Number of Auxiliary Contacts NO: Number of Auxiliary Contacts NC: Standards: Rated Operational Voltage: 0 1 0 IEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1, UL 508, CSA C22.2 N°14 Auxiliary Circuit 690 V Main Circuit 690 V Rated Frequency (f): Auxiliary Circuit 50 / 60 Hz Main Circuit 50 / 60 Hz Conventional Free-air Thermal acc. to IEC 60947-4-1, Open Contactors q = 40 °C 35 A Current (Ith): acc. to IEC 60947-5-1, q = 40 °C 16 A Rated Operational Current AC-1 (Ie): (690 V) 40 °C 28 A (690 V) 60 °C 28 A (690 V) 70 °C 24 A Rated Operational Current AC-3 (Ie): (220 / 230 / 240 V) 60 °C 12 A (380 / 400 V) 60 °C 12 A (415 V) 60 °C 12 A (440 V) 60 °C 12 A (500 V) 60 °C 12.5 A (690 V) 60 °C 9 A Rated Operational Power AC-3 (Pe): (220 / 230 / 240 V) 3 kW (380 / 400 V) 5.5 kW (400 V) 5.5 kW (415 V) 5.5 kW (440 V) 5.5 kW (500 V) 7.5 kW (690 V) 7.5 kW Rated Operational Current AC-15 (220 / 240 V) 4 A (Ie): (24 / 127 V) 6 A (400 / 440 V) 3 A (500 V) 2 A (690 V) 2 A Rated Short-time Withstand Current at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 150 A (Icw): at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 35 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 60 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 300 A at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 80 A for 0.1 s 140 A for 1 s 100 A Maximum Breaking Capacity: cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 A cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 106 A Maximum Electrical Switching AC-1 600 cycles per hour Frequency: AC-15 1200 cycles per hour AC-2 / AC-4 300 cycles per hour AC-3 1200 cycles per hour DC-13 900 cycles per hour Rated Operational Current DC-13 (110 V) 0.55 A / 60 W (Ie): (125 V) 0.55 A / 69 W (220 V) 0.27 A / 60 W (24 V) 6 A / 144 W (250 V) 0.27 A / 68 W (400 V) 0.15 A / 60 W (48 V) 2.8 A / 134 W (500 V) 0.13 A / 65 W (600 V) 0.1 A / 60 W (72 V) 1 A / 72 W Rated Insulation Voltage (Ui): acc. to UL/CSA 600 V acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V Rated Impulse Withstand Voltage 6 kV (Uimp): Maximum Mechanical Switching 3600 cycles per hour Frequency: Rated Control Circuit Voltage (Uc): 50 Hz 48 ... 130 V 60 Hz 48 ... 130 V DC Operation 48 ... 130 V Operate Time: Between Coil De-energization and NC Contact Closing 13...98 ms Between Coil De-energization and NO Contact Opening 11...95 ms Between Coil Energization and NC Contact Opening 38...90 ms Between Coil Energization and NO Contact Closing 40...95 ms Connecting Capacity Main Circuit: Flexible with Insulated Ferrule 1x 0.75...4 mm² Flexible with Insulated Ferrule 2x 0.75...2.5 mm² Flexible with Ferrule 1/2x 0.75...6 mm² Rigid 1/2x 1...6 mm² Connecting Capacity Auxiliary Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² Circuit: Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² Rigid 1/2x 1...2.5 mm² Connecting Capacity Control Circuit: Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² Rigid 1/2x 1 ... 2.5 mm² Wire Stripping Length: Auxiliary Circuit 10 mm Control Circuit 10 mm Main Circuit 10 mm Degree of Protection: acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20 acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20 Terminal Type: Screw Terminals Number of Main Contacts NO: 3 Environmental Climatic Withstand: Category B according to IEC 60947-1 Annex Q Maximum Operating Altitude 3000 m Permissible: Resistance to Vibrations acc. to IEC 5 ... 300 Hz 4 g closed position / 2 g open position 60068-2-6: Resistance to Shock acc. to IEC 60068-2-27: RoHS Status: Ambient Air Temperature: Closed, Shock Direction: B1 25 g Open, Shock Direction: B1 5 g Shock Direction: A 30 g Shock Direction: B2 15 g Shock Direction: C1 25 g Shock Direction: C2 25 g Planned to follow EU Directive 2002/95/EC August 18, 2005 and amendment after 2008 Q1 Close to Contactor for Storage -60...+80 °C Close to Contactor Fitted with Thermal O/L Relay -25 ... +60 °C Close to Contactor without Thermal O/L Relay -40 ... +70 °C Technical UL/CSA General Use Rating UL/CSA: Horsepower Rating UL/CSA: Tightening Torque UL/CSA: (600 V AC) 28 A (120 V AC) Single Phase 1 Hp (240 V AC) Single Phase 2 Hp (200 ... 208 V AC) Three Phase 3 Hp (220 ... 240 V AC) Three Phase 3 Hp (440 ... 480 V AC) Three Phase 7-1/2 Hp (550 ... 600 V AC) Three Phase 10 Hp Auxiliary Circuit 11 in·lb Control Circuit 11 in·lb Main Circuit 13 in·lb Certificates and Declarations (Document Number) Instructions and Manuals: ABS Certificate: CB Certificate: CCC Certificate: Data Sheet, Technical Information: Declaration of Conformity - CE: DNV Certificate: EAC Certificate: GL Certificate: GOST Certificate: LR Certificate: RINA Certificate: RMRS Certificate: RoHS Information: UL Certificate: UL Listing Card: 1SBC101027M6801 ABS_15-GE1349500-PDA_90682247 CB_SE_70855M1 CCC_2010010304445624 1SBC101404D0201 1SBD250000U1000 DNV-GL_E13871 EAC_RU C-FR ME77 B01010 DNV-GL_E13871 GOST_POCCFR.ME77.B07175.pdf LRS_1300087E1 RINA_ELE084013XG RMRS_1400682124 1SBD251013E1000 UL_20140305-E312527_7_1 UL_E312527 Classifications E-nummer: ETIM 4: ETIM 5: ETIM 6: UNSPSC: Object Classification Code: 3211362 EC000066 - Magnet contactor, AC-switching EC000066 - Magnet contactor, AC-switching EC000066 - Power contactor, AC switching 39121529 Q
AF12-30-10-12 价格&库存

很抱歉,暂时无法提供与“AF12-30-10-12”相匹配的价格&库存,您可以联系我们找货

免费人工找货