AF140-30-11-11 24-60V 50/60Hz / 20-60V DC
General Information
Extended Product Type:
Product ID:
EAN:
Catalog Description:
Long Description:
AF140-30-11-11 24-60V 50/60Hz / 20-60V DC
1SFL447001R1111
7320500477069
AF140-30-11-11 Contactor
A 3-phase Contactor suitable for various applications such as Motor starting, Isolation, Bypass and Distribution application up to max 690 V. Operated with wide control voltage range
24-60 V, 50 and 60 Hz, 20-60 V DC
Categories
Products » Low Voltage Products and Systems » Control Products » Contactors » Block Contactors
Ordering
Minimum Order Quantity:
Customs Tariff Number:
EAN:
1 piece
85364900
7320500477069
Dimensions
Product Net Depth:
Product Net Height:
Product Net Weight:
Product Net Width:
126.0 mm
150.0 mm
1.644 kg
90.0 mm
Container Information
Package Level 1 Width:
Package Level 1 Length:
Package Level 1 Height:
Package Level 1 Gross Weight:
Package Level 1 EAN:
Package Level 1 Units:
194 mm
115 mm
169 mm
1.774 kg
7320500477069
1 piece
Technical
Number of Main Contacts NC:
Number of Auxiliary Contacts NO:
Number of Auxiliary Contacts NC:
Rated Operational Voltage:
Rated Frequency (f):
Conventional Free-air Thermal
Current (Ith):
Rated Operational Current AC-1 (Ie):
Rated Operational Current AC-3 (Ie):
Rated Operational Power AC-3 (Pe):
Rated Breaking Capacity AC-3 acc.
to IEC 60947-4-1:
Rated Making Capacity AC-3 acc. to
IEC 60947-4-1:
Short-Circuit Protective Devices:
Rated Short-time Withstand Current
(Icw):
Maximum Breaking Capacity:
0
1
1
Main Circuit 690 V
Main Circuit 50/60 Hz
acc. to IEC 60947-4-1, Open Contactors q = 40 °C 200 A
(690 V) 55 °C 175 A
(690 V) 40 °C 200 A
(690 V) 70 °C 160 A
(415 V) 55 °C 140 A
(690 V) 55 °C 80 A
(220 / 230 / 240 V) 55 °C 140 A
(440 V) 55 °C 140 A
(380 / 400 V) 55 °C 140 A
(500 V) 55 °C 130 A
(500 V) 90 kW
(220 / 230 / 240 V) 37 kW
(690 V) 75 kW
(380 / 400 V) 75 kW
(440 V) 90 kW
(415 V) 75 kW
8 x Ie AC-3
10 x Ie AC-3
gG Type Fuses 315 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 674 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 200 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 1168 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1460 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 477 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 3000 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 1500 A
Maximum Electrical Switching
Frequency:
Rated Operational Current DC-1 (Ie):
Rated Operational Current DC-3 (Ie):
Rated Operational Current DC-5 (Ie):
Rated Insulation Voltage (Ui):
Rated Impulse Withstand Voltage
(Uimp):
Mechanical Durability:
Maximum Mechanical Switching
Frequency:
Coil Operating Limits:
Rated Control Circuit Voltage (Uc):
Coil Consumption:
Operate Time:
Connecting Capacity Main Circuit:
Connecting Capacity Auxiliary
Circuit:
Degree of Protection:
Terminal Type:
Number of Main Contacts NO:
AC-3 300 cycles per hour
AC-1 300 cycles per hour
AC-2 / AC-4 150 cycles per hour
(110 V) 2 Poles in Series, 40 °C 160 A
(220 V) 3 Poles in Series, 40 °C 160 A
(110 V) 2 Poles in Series, 40 °C 160 A
(220 V) 3 Poles in Series, 40 °C 160 A
(110 V) 2 Poles in Series, 40 °C 160 A
(220 V) 3 Poles in Series, 40 °C 160 A
acc. to UL/CSA 600 V
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
Main Circuit 8 kV
5 million
300 cycles per hour
(acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C) °C
60 Hz 24…60 V
50 Hz 24…60 V
DC Operation 20…60 V
Pull-in at Max. Rated Control Circuit Voltage 60 Hz 225 V·A
Holding at Max. Rated Control Circuit Voltage DC 2.5 W
Holding at Max. Rated Control Circuit Voltage 50 Hz 5.5 V·A
Pull-in at Max. Rated Control Circuit Voltage DC 210 W
Pull-in at Max. Rated Control Circuit Voltage 50 Hz 225 V·A
Holding at Max. Rated Control Circuit Voltage 60 Hz 5.5 V·A
Between Coil Energization and NO Contact Closing 25…55 ms
Between Coil De-energization and NO Contact Opening 37…47 ms
Rigid Cu-Cable 2x10…95 mm²
Flexible 1x10…70 mm²
Solid 2x1…4 mm²
Flexible with Insulated Ferrule 2x0.75…2.5 mm²
Stranded 2x1…4 mm²
Flexible 1x0.75…2.5 mm²
Flexible with Ferrule 1x0.75…2.5 mm²
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Double Clamp
3
Environmental
Maximum Operating Altitude
Permissible:
RoHS Status:
Ambient Air Temperature:
3000 m
Following EU Directive 2002/95/EC August 18, 2005 and amendment
Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25…+50 °C
Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40…+70 °C
Close to Contactor for Storage -40…+70 °C
Technical UL/CSA
General Use Rating UL/CSA:
Horsepower Rating UL/CSA:
Maximum Operating Voltage
UL/CSA:
(600 V AC) 200 A
(208 V AC) Three Phase 40 Hp
(440 ... 480 V AC) Three Phase 100 Hp
(550 ... 600 V AC) Three Phase 125 Hp
(220 ... 240 V AC) Three Phase 50 Hp
(200 V AC) Three Phase 40 Hp
Main Circuit 600 V
Certificates and Declarations (Document Number)
Instructions and Manuals:
CB Certificate:
CCC Certificate:
Data Sheet, Technical Information:
Declaration of Conformity - CE:
RINA Certificate:
RoHS Information:
1SFC100003M0201
SE-70480
CQC_2013010304604055
1SFC101070D0201
2CMT004242
ELE060313XG/002
1SFC101055D0202
Classifications
ETIM 4:
ETIM 5:
UNSPSC:
EC000066 - Magnet contactor, AC-switching
EC000066 - Magnet contactor, AC-switching
39121529
Object Classification Code:
Q