0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
AF140-30-11-13

AF140-30-11-13

  • 厂商:

    ABB

  • 封装:

  • 描述:

    ABB - AF140-30-11-13 - Contactor, 140 A, DIN Rail, 690 V, 3PST-NO, 3 Pole, 90 kW

  • 数据手册
  • 价格&库存
AF140-30-11-13 数据手册
AF140-30-11-13 100-250V 50/60Hz / DC General Information Extended Product Type: Product ID: EAN: Catalog Description: Long Description: AF140-30-11-13 100-250V 50/60Hz / DC 1SFL447001R1311 7320500476949 AF140-30-11-13 Contactor A 3-phase Contactor suitable for various applications such as Motor starting, Isolation, Bypass and Distribution application up to max 690 V. Operated with wide control voltage range 100-250 V, 50/60 Hz and DC Categories Products » Low Voltage Products and Systems » Control Products » Contactors » Block Contactors Ordering Minimum Order Quantity: Customs Tariff Number: EAN: 1 piece 85364900 7320500476949 Dimensions Product Net Depth: Product Net Height: Product Net Weight: Product Net Width: 126.0 mm 150.0 mm 1.644 kg 90.0 mm Container Information Package Level 1 Width: Package Level 1 Length: Package Level 1 Height: Package Level 1 Gross Weight: Package Level 1 EAN: Package Level 1 Units: 194 mm 115 mm 169 mm 1.57 kg 7320500476949 1 piece Technical Number of Main Contacts NC: Number of Auxiliary Contacts NO: Number of Auxiliary Contacts NC: Rated Operational Voltage: Rated Frequency (f): Conventional Free-air Thermal Current (Ith): Rated Operational Current AC-1 (Ie): Rated Operational Current AC-3 (Ie): Rated Operational Power AC-3 (Pe): Rated Breaking Capacity AC-3 acc. to IEC 60947-4-1: Rated Making Capacity AC-3 acc. to IEC 60947-4-1: Short-Circuit Protective Devices: Rated Short-time Withstand Current (Icw): Maximum Breaking Capacity: 0 1 1 Main Circuit 690 V Main Circuit 50/60 Hz acc. to IEC 60947-4-1, Open Contactors q = 40 °C 200 A (690 V) 55 °C 175 A (690 V) 40 °C 200 A (690 V) 70 °C 160 A (690 V) 55 °C 80 A (415 V) 55 °C 140 A (220 / 230 / 240 V) 55 °C 140 A (440 V) 55 °C 140 A (380 / 400 V) 55 °C 140 A (500 V) 55 °C 130 A (500 V) 90 kW (690 V) 75 kW (220 / 230 / 240 V) 37 kW (380 / 400 V) 75 kW (440 V) 90 kW (415 V) 75 kW 8 x Ie AC-3 10 x Ie AC-3 gG Type Fuses 315 A at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 200 A at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 674 A at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 1168 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1460 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 477 A cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 3000 A cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 1500 A Maximum Electrical Switching Frequency: Rated Operational Current DC-1 (Ie): Rated Operational Current DC-3 (Ie): Rated Operational Current DC-5 (Ie): Rated Insulation Voltage (Ui): Rated Impulse Withstand Voltage (Uimp): Mechanical Durability: Maximum Mechanical Switching Frequency: Coil Operating Limits: Rated Control Circuit Voltage (Uc): Coil Consumption: Operate Time: Connecting Capacity Main Circuit: Connecting Capacity Auxiliary Circuit: Degree of Protection: Terminal Type: Number of Main Contacts NO: AC-3 300 cycles per hour AC-1 300 cycles per hour AC-2 / AC-4 150 cycles per hour (110 V) 2 Poles in Series, 40 °C 160 A (220 V) 3 Poles in Series, 40 °C 160 A (110 V) 2 Poles in Series, 40 °C 160 A (220 V) 3 Poles in Series, 40 °C 160 A (110 V) 2 Poles in Series, 40 °C 160 A (220 V) 3 Poles in Series, 40 °C 160 A acc. to UL/CSA 600 V acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V Main Circuit 8 kV 5 million 300 cycles per hour (acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C) °C 60 Hz 100…250 V 50 Hz 100…250 V DC Operation 100…250 V Pull-in at Max. Rated Control Circuit Voltage 60 Hz 130 V·A Holding at Max. Rated Control Circuit Voltage DC 3 W Holding at Max. Rated Control Circuit Voltage 50 Hz 6 V·A Pull-in at Max. Rated Control Circuit Voltage DC 135 W Pull-in at Max. Rated Control Circuit Voltage 50 Hz 130 V·A Holding at Max. Rated Control Circuit Voltage 60 Hz 6 V·A Between Coil Energization and NO Contact Closing 25…55 ms Between Coil De-energization and NO Contact Opening 37…47 ms Rigid Cu-Cable 2x10…95 mm² Flexible 2x10…70 mm² Solid 2x1…4 mm² Flexible with Insulated Ferrule 2x0.75…2.5 mm² Stranded 2x1…4 mm² Flexible 2x0.75…2.5 mm² Flexible with Ferrule 2x0.75…2.5 mm² acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00 Double Clamp 3 Environmental Maximum Operating Altitude Permissible: RoHS Status: Ambient Air Temperature: 3000 m Following EU Directive 2002/95/EC August 18, 2005 and amendment Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25…+50 °C Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40…+70 °C Close to Contactor for Storage -40…+70 °C Technical UL/CSA General Use Rating UL/CSA: Horsepower Rating UL/CSA: Maximum Operating Voltage UL/CSA: (600 V AC) 200 A (208 V AC) Three Phase 40 Hp (440 ... 480 V AC) Three Phase 100 Hp (550 ... 600 V AC) Three Phase 125 Hp (220 ... 240 V AC) Three Phase 50 Hp (200 V AC) Three Phase 40 Hp Main Circuit 600 V Certificates and Declarations (Document Number) Instructions and Manuals: CB Certificate: CCC Certificate: Data Sheet, Technical Information: Declaration of Conformity - CE: RINA Certificate: RoHS Information: 1SFC100003M0201 SE-70480 CQC_2013010304604055 1SFC101070D0201 2CMT004242 ELE060313XG/002 1SFC101055D0202 Classifications ETIM 4: ETIM 5: UNSPSC: EC000066 - Magnet contactor, AC-switching EC000066 - Magnet contactor, AC-switching 39121529 Object Classification Code: Q
AF140-30-11-13 价格&库存

很抱歉,暂时无法提供与“AF140-30-11-13”相匹配的价格&库存,您可以联系我们找货

免费人工找货