AF140-30-11-13 100-250V 50/60Hz / DC
General Information
Extended Product Type:
Product ID:
EAN:
Catalog Description:
Long Description:
AF140-30-11-13 100-250V 50/60Hz / DC
1SFL447001R1311
7320500476949
AF140-30-11-13 Contactor
A 3-phase Contactor suitable for various applications such as Motor starting, Isolation, Bypass and Distribution application up to max 690 V. Operated with wide control voltage range
100-250 V, 50/60 Hz and DC
Categories
Products » Low Voltage Products and Systems » Control Products » Contactors » Block Contactors
Ordering
Minimum Order Quantity:
Customs Tariff Number:
EAN:
1 piece
85364900
7320500476949
Dimensions
Product Net Depth:
Product Net Height:
Product Net Weight:
Product Net Width:
126.0 mm
150.0 mm
1.644 kg
90.0 mm
Container Information
Package Level 1 Width:
Package Level 1 Length:
Package Level 1 Height:
Package Level 1 Gross Weight:
Package Level 1 EAN:
Package Level 1 Units:
194 mm
115 mm
169 mm
1.57 kg
7320500476949
1 piece
Technical
Number of Main Contacts NC:
Number of Auxiliary Contacts NO:
Number of Auxiliary Contacts NC:
Rated Operational Voltage:
Rated Frequency (f):
Conventional Free-air Thermal
Current (Ith):
Rated Operational Current AC-1 (Ie):
Rated Operational Current AC-3 (Ie):
Rated Operational Power AC-3 (Pe):
Rated Breaking Capacity AC-3 acc.
to IEC 60947-4-1:
Rated Making Capacity AC-3 acc. to
IEC 60947-4-1:
Short-Circuit Protective Devices:
Rated Short-time Withstand Current
(Icw):
Maximum Breaking Capacity:
0
1
1
Main Circuit 690 V
Main Circuit 50/60 Hz
acc. to IEC 60947-4-1, Open Contactors q = 40 °C 200 A
(690 V) 55 °C 175 A
(690 V) 40 °C 200 A
(690 V) 70 °C 160 A
(690 V) 55 °C 80 A
(415 V) 55 °C 140 A
(220 / 230 / 240 V) 55 °C 140 A
(440 V) 55 °C 140 A
(380 / 400 V) 55 °C 140 A
(500 V) 55 °C 130 A
(500 V) 90 kW
(690 V) 75 kW
(220 / 230 / 240 V) 37 kW
(380 / 400 V) 75 kW
(440 V) 90 kW
(415 V) 75 kW
8 x Ie AC-3
10 x Ie AC-3
gG Type Fuses 315 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 200 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 674 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 1168 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1460 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 477 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 3000 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 1500 A
Maximum Electrical Switching
Frequency:
Rated Operational Current DC-1 (Ie):
Rated Operational Current DC-3 (Ie):
Rated Operational Current DC-5 (Ie):
Rated Insulation Voltage (Ui):
Rated Impulse Withstand Voltage
(Uimp):
Mechanical Durability:
Maximum Mechanical Switching
Frequency:
Coil Operating Limits:
Rated Control Circuit Voltage (Uc):
Coil Consumption:
Operate Time:
Connecting Capacity Main Circuit:
Connecting Capacity Auxiliary
Circuit:
Degree of Protection:
Terminal Type:
Number of Main Contacts NO:
AC-3 300 cycles per hour
AC-1 300 cycles per hour
AC-2 / AC-4 150 cycles per hour
(110 V) 2 Poles in Series, 40 °C 160 A
(220 V) 3 Poles in Series, 40 °C 160 A
(110 V) 2 Poles in Series, 40 °C 160 A
(220 V) 3 Poles in Series, 40 °C 160 A
(110 V) 2 Poles in Series, 40 °C 160 A
(220 V) 3 Poles in Series, 40 °C 160 A
acc. to UL/CSA 600 V
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
Main Circuit 8 kV
5 million
300 cycles per hour
(acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C) °C
60 Hz 100…250 V
50 Hz 100…250 V
DC Operation 100…250 V
Pull-in at Max. Rated Control Circuit Voltage 60 Hz 130 V·A
Holding at Max. Rated Control Circuit Voltage DC 3 W
Holding at Max. Rated Control Circuit Voltage 50 Hz 6 V·A
Pull-in at Max. Rated Control Circuit Voltage DC 135 W
Pull-in at Max. Rated Control Circuit Voltage 50 Hz 130 V·A
Holding at Max. Rated Control Circuit Voltage 60 Hz 6 V·A
Between Coil Energization and NO Contact Closing 25…55 ms
Between Coil De-energization and NO Contact Opening 37…47 ms
Rigid Cu-Cable 2x10…95 mm²
Flexible 2x10…70 mm²
Solid 2x1…4 mm²
Flexible with Insulated Ferrule 2x0.75…2.5 mm²
Stranded 2x1…4 mm²
Flexible 2x0.75…2.5 mm²
Flexible with Ferrule 2x0.75…2.5 mm²
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Double Clamp
3
Environmental
Maximum Operating Altitude
Permissible:
RoHS Status:
Ambient Air Temperature:
3000 m
Following EU Directive 2002/95/EC August 18, 2005 and amendment
Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25…+50 °C
Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40…+70 °C
Close to Contactor for Storage -40…+70 °C
Technical UL/CSA
General Use Rating UL/CSA:
Horsepower Rating UL/CSA:
Maximum Operating Voltage
UL/CSA:
(600 V AC) 200 A
(208 V AC) Three Phase 40 Hp
(440 ... 480 V AC) Three Phase 100 Hp
(550 ... 600 V AC) Three Phase 125 Hp
(220 ... 240 V AC) Three Phase 50 Hp
(200 V AC) Three Phase 40 Hp
Main Circuit 600 V
Certificates and Declarations (Document Number)
Instructions and Manuals:
CB Certificate:
CCC Certificate:
Data Sheet, Technical Information:
Declaration of Conformity - CE:
RINA Certificate:
RoHS Information:
1SFC100003M0201
SE-70480
CQC_2013010304604055
1SFC101070D0201
2CMT004242
ELE060313XG/002
1SFC101055D0202
Classifications
ETIM 4:
ETIM 5:
UNSPSC:
EC000066 - Magnet contactor, AC-switching
EC000066 - Magnet contactor, AC-switching
39121529
Object Classification Code:
Q