0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
AF190-30-11-11

AF190-30-11-11

  • 厂商:

    ABB

  • 封装:

  • 描述:

    ABB - AF190-30-11-11 - Contactor, 190 A, DIN Rail, 1 kV, 3PST-NO, 3 Pole, 55 kW

  • 数据手册
  • 价格&库存
AF190-30-11-11 数据手册
AF190-30-11-11 24-60V 50/60Hz / 20-60V DC General Information Extended Product Type: Product ID: EAN: Catalog Description: Long Description: AF190-30-11-11 24-60V 50/60Hz / 20-60V DC 1SFL487002R1111 7320500480410 AF190-30-11-11 Contactor A 3-phase Contactor suitable for various applications such as Motor starting, Isolation, Bypass and Distribution application up to max 1000 V. Operated with wide control voltage range 24-60 V, 50 and 60 Hz, 20-60 V DC Categories Products » Low Voltage Products and Systems » Control Products » Contactors » Block Contactors Ordering Minimum Order Quantity: Customs Tariff Number: EAN: 1 piece 85364900 7320500480410 Dimensions Product Net Depth: Product Net Height: Product Net Weight: Product Net Width: 152.0 mm 196.0 mm 2.778 kg 105.0 mm Container Information Package Level 1 Width: Package Level 1 Length: Package Level 1 Height: Package Level 1 Gross Weight: Package Level 1 EAN: Package Level 1 Units: 223 mm 133 mm 186 mm 3.228 kg 7320500480410 1 piece Technical Number of Main Contacts NC: Number of Auxiliary Contacts NO: Number of Auxiliary Contacts NC: Rated Operational Voltage: Rated Frequency (f): Conventional Free-air Thermal Current (Ith): Rated Operational Current AC-1 (Ie): 0 1 1 Main Circuit 1000 V Main Circuit 50/60 Hz acc. to IEC 60947-4-1, Open Contactors q = 40 °C 275 A (690 V) 55 °C 250 A (690 V) 40 °C 275 A (1000 V) 40 °C 250 A (1000 V) 55 °C 225 A (690 V) 70 °C 200 A (1000 V) 70 °C 185 A Rated Operational Current AC-3 (Ie): (1000 V) 55 °C 85 A (415 V) 55 °C 190 A (690 V) 55 °C 135 A (220 / 230 / 240 V) 55 °C 190 A (440 V) 55 °C 190 A (380 / 400 V) 55 °C 190 A (500 V) 55 °C 135 A Rated Operational Power AC-3 (Pe): (500 V) 90 kW (1000 V) 110 kW (220 / 230 / 240 V) 55 kW (690 V) 132 kW (380 / 400 V) 90 kW (440 V) 110 kW (415 V) 90 kW Rated Breaking Capacity AC-3 acc. 8 x Ie AC-3 to IEC 60947-4-1: Rated Making Capacity AC-3 acc. to 10 x Ie AC-3 IEC 60947-4-1: Short-Circuit Protective Devices: gG Type Fuses 355 A Rated Short-time Withstand Current at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 275 A (Icw): at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 878 A Maximum Breaking Capacity: Maximum Electrical Switching Frequency: Rated Operational Current DC-1 (Ie): Rated Operational Current DC-3 (Ie): Rated Operational Current DC-5 (Ie): Rated Insulation Voltage (Ui): Rated Impulse Withstand Voltage (Uimp): Mechanical Durability: Maximum Mechanical Switching Frequency: Coil Operating Limits: Rated Control Circuit Voltage (Uc): Coil Consumption: Operate Time: Connecting Capacity Main Circuit: Connecting Capacity Auxiliary Circuit: Degree of Protection: Terminal Type: Number of Main Contacts NO: at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 1520 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1900 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 621 A cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 3300 A cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 2200 A AC-3 300 cycles per hour AC-1 300 cycles per hour AC-2 / AC-4 150 cycles per hour (110 V) 2 Poles in Series, 40 °C 250 A (220 V) 3 Poles in Series, 40 °C 250 A (110 V) 2 Poles in Series, 40 °C 250 A (220 V) 3 Poles in Series, 40 °C 250 A (110 V) 2 Poles in Series, 40 °C 250 A (220 V) 3 Poles in Series, 40 °C 250 A acc. to UL/CSA 600 V acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V Main Circuit 8 kV 5 million 300 cycles per hour (acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C) °C 60 Hz 24…60 V 50 Hz 24…60 V DC Operation 20…60 V Pull-in at Max. Rated Control Circuit Voltage 60 Hz 165 V·A Holding at Max. Rated Control Circuit Voltage DC 2.5 W Holding at Max. Rated Control Circuit Voltage 50 Hz 6 V·A Pull-in at Max. Rated Control Circuit Voltage DC 205 W Pull-in at Max. Rated Control Circuit Voltage 50 Hz 165 V·A Holding at Max. Rated Control Circuit Voltage 60 Hz 6 V·A Between Coil Energization and NO Contact Closing 25…55 ms Between Coil De-energization and NO Contact Opening 37…47 ms Rigid Al-Cable 1x95…185 mm² Flexible 2x50…95 mm² Rigid Cu-Cable 2x50…120 mm² Solid 2x1…4 mm² Flexible with Insulated Ferrule 2x0.75…2.5 mm² Stranded 2x1…4 mm² Flexible 2x0.75…2.5 mm² Flexible with Ferrule 2x0.75…2.5 mm² acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00 Main Circuit: Bars 3 Environmental Maximum Operating Altitude Permissible: RoHS Status: Ambient Air Temperature: 3000 m Following EU Directive 2002/95/EC August 18, 2005 and amendment Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25…+50 °C Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40…+70 °C Close to Contactor for Storage -40…+70 °C Technical UL/CSA General Use Rating UL/CSA: Horsepower Rating UL/CSA: Maximum Operating Voltage UL/CSA: (600 V AC) 250 A (208 V AC) Three Phase 50 Hp (440 ... 480 V AC) Three Phase 125 Hp (550 ... 600 V AC) Three Phase 150 Hp (220 ... 240 V AC) Three Phase 60 Hp (200 V AC) Three Phase 50 Hp Main Circuit 600 V Certificates and Declarations (Document Number) Instructions and Manuals: CB Certificate: Data Sheet, Technical Information: Declaration of Conformity - CE: RINA Certificate: RoHS Information: 1SFC100008M0201 SE-71797M1 1SFC101070D0201 2CMT004613 ELE060313XG/002 1SFC101055D0202 Classifications E-nummer: ETIM 4: ETIM 5: UNSPSC: Object Classification Code: 3210132 EC000066 - Magnet contactor, AC-switching EC000066 - Magnet contactor, AC-switching 39121529 Q
AF190-30-11-11 价格&库存

很抱歉,暂时无法提供与“AF190-30-11-11”相匹配的价格&库存,您可以联系我们找货

免费人工找货