0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
AF26-22-00-12

AF26-22-00-12

  • 厂商:

    ABB

  • 封装:

  • 描述:

    ABB - AF26-22-00-12 - Contactor, 23.2 A, DIN Rail, 690 V, DPST-NO, DPST-NC, 4 Pole, 5.5 kW

  • 数据手册
  • 价格&库存
AF26-22-00-12 数据手册
AF09 ... AF38 3-pole Contactors up to 18.5 kW / 20 hp Overview ...................................................................................................................................... 2 Ordering Details – AF09 ... AF38 3-pole Contactors................................................................................................ 4 – AF..Z Additional Coils................................................................................................................... 5 Technical Data ............................................................................................................................. 6 Main Accessory Fitting Details.................................................................................................. 11 Accessory Ordering Details and Technical Data....................................................................... 12 Terminal Marking and Positioning............................................................................................. 18 1SBC 101 134 S0201 Dimensions................................................................................................................................. 20 ABB | 1 AF09 ... AF16 3-pole contactors AF26 ... AF38 3-pole contactors for Contactors CAT4-11 2-pole auxiliary contact and A1/A2 coil terminal block BX4-CA Protective cover VM4 BX4-CA Protective cover CA4 4-pole auxiliary contact block A2 CA4, CC4 1-pole auxiliary contact block CAL4-11 2-pole auxiliary contact block Top or bottom mounted coil terminal block BX4 Protective cover VM4  BB4 Fixing clips VE4  VEM4 mechanical and electrical interlock set including:  VM4 mechanical interlock unit including 2 fixing clips (BB4)  VE4 electrical interlock block with A2-A2 connection for Starting Solutions Direct-On-Line Starter Reversing Starter Star-Delta Starter VEM4 mechanical & electrical interlock set BER..-4 Connection set including: - Phase-to-phase connection - Parallel connection TF42 Thermal overload relay EF.. Electronic overload relay 2 | ABB A2 TF42 Thermal overload relay EF.. Electronic overload relay VEM4 mechanical & electrical interlock set BEY..-4 Connection set including: - Phase-to-phase connection - Parallel connection - Star connection TF42 Thermal overload relay EF.. Electronic overload relay 1SBC 101 090 S0201 Main Accessories Fixing clips 3-pole Contactors AC / DC control voltage AF09 AF12 AF16 AF26 AF09-30-10 AF12-30-10 AF16-30-10 AF30 AF38 AF26-30-00 AF30-30-00 AF38-30-00 AF09-30-01 AF12-30-01 AF16-30-01 Switching of 3-phase Cage Motors Rated power 33 M 3 IEC UL/CSA AC-3 Rated operational current 400 V θ ≤ 60 °C 400 V θ ≤ 60 °C 415 V θ ≤ 60 °C 690 V 480 V Motor rating Nema size 4 kW 9A 9A 7A 5 hp 00 5.5 kW 12 A 12 A 9A 7.5 hp 0 7.5 kW 18 A 18 A 10.5 A 10 hp - 11 kW 26 A 26 A 17 A 15 hp 1 15 kW 32 A 32 A 21 A 20 hp - 18.5 kW 38 A 38 A 24 A 20 hp - Protection of 3-phase motors TF42... setting range in A Thermal overload relays EF19... Electronic overload relays 0.10 ... 0.32 EF45... setting range in A 0.30 ... 1.0 0.80 ... 2.7 setting range in A 1.90 ... 6.3 5.7 ... 18.9 9.0 ... 30 15 ... 45 Switching of Resistive Circuits 33 IEC AC-1 Rated operational current θ ≤ 40 °C 690 V θ ≤ 60 °C 690 V θ ≤ 70 °C 690 V With conductor cross-sectional area R R UL/CSA General use rating With conductor cross-sectional area 600 V AC 25 A 25 A 22 A 4 mm2 25 A AWG 10 28 A 28 A 24 A 6 mm2 28 A AWG 10 30 A 30 A 26 A 6 mm2 30 A AWG 10 45 A 40 A 32 A 10 mm2 45 A AWG 8 50 A 42 A 37 A 10 mm2 50 A AWG 8 50 A 42 A 37 A 10 mm2 50 A AWG 8 Main Accessories 1-pole CA4-10 or CA4-01, CC4-10 or CC4-01 Auxiliary contact blocks 4-pole CA4 Front mounting 2-pole CAT4-11 (with coil front connection) 2-pole CAL4-11 Side mounting Mechanical / electrical VEM4 including VM4 mechanical interlock unit and VE4 electrical interlock block with A2-A2 connection Interlocks VM4 Mechanical including 2 fixing clips Reversing Starters BER16-4 BER38-4 Star-Delta Starters BEY16-4 BEY38-4 1SBC 101 090 S0201 Connection sets ABB | 3 AF09 ... AF38 3-pole Contactors AC / DC Operated - with Screw Terminals Catalogue Page 1SBC 101 060 S0201 4 to 18.5 kW 5 to 20 hp Application cULus CE AF09 ... AF38 contactors are used for controlling power circuits up to 690 V AC and 220 V DC. They are mainly used for controlling 3-phase motors, non-inductive or slightly inductive loads. Description –– AF09 ... AF38 contactors include an electronic coil interface accepting a wide control voltage Uc min. ... Uc max. Only four coils cover control voltages between 24...500 V 50/60 Hz or 20...500 V DC –– AF contactors can manage large control voltage variations. One coil (e.g. 100...250 V 50/60 Hz - DC) can be used for different control voltages used worldwide without any coil change –– AF..Z contactors equipped with a Z coil type allow direct control by 24 V DC 500 mA PLC-output and obtain a reduced holding coil consumption. AF..Z contactors withstand short dips and voltage interruptions (SEMI F47-0706 compliance) –– AF contactors have built-in surge protection and do not require additional surge suppressors –– The built-in N.C. auxiliary contact is a mirror contact in compliance with annex F of IEC 60947-4-1. AF09-30-10 Ordering Details IEC UL/CSA Rated power 400 V AC-3 kW 4 3-phase Uc min. ... Uc max. motor rating 480 V hp V 50/60 Hz V DC 5 24...60 20...60 24...60 20...60 48...130 48...130 48...130 48...130 100...250 100...250 100...250 100...250 250...500 250...500 250...500 250...500 7.5 24...60 20...60 24...60 20...60 48...130 48...130 48...130 48...130 100...250 100...250 100...250 100...250 250...500 250...500 250...500 250...500 10 24...60 20...60 24...60 20...60 48...130 48...130 48...130 48...130 100...250 100...250 100...250 100...250 250...500 250...500 250...500 250...500 15 24...60 20...60 48...130 48...130 100...250 100...250 250...500 250...500 20 24...60 20...60 48...130 48...130 100...250 100...250 250...500 250...500 20 24...60 20...60 48...130 48...130 100...250 100...250 250...500 250...500 5.5 AF26-30-00 7.5 11 15 18.5 4 | ABB Control voltage Auxiliary Type contacts fitted Order code Weight Pack(ing) 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 0 0 0 0 0 0 0 0 0 0 0 AF09Z-30-10-21 AF09Z-30-01-21 AF09-30-10-12 AF09-30-01-12 AF09-30-10-13 AF09-30-01-13 AF09-30-10-14 AF09-30-01-14 AF12Z-30-10-21 AF12Z-30-01-21 AF12-30-10-12 AF12-30-01-12 AF12-30-10-13 AF12-30-01-13 AF12-30-10-14 AF12-30-01-14 AF16Z-30-10-21 AF16Z-30-01-21 AF16-30-10-12 AF16-30-01-12 AF16-30-10-13 AF16-30-01-13 AF16-30-10-14 AF16-30-01-14 AF26Z-30-00-21 AF26-30-00-12 AF26-30-00-13 AF26-30-00-14 AF30Z-30-00-21 AF30-30-00-12 AF30-30-00-13 AF30-30-00-14 AF38Z-30-00-21 AF38-30-00-12 AF38-30-00-13 AF38-30-00-14 1SBL 136 001 R2110 1SBL 136 001 R2101 1SBL 137 001 R1210 1SBL 137 001 R1201 1SBL 137 001 R1310 1SBL 137 001 R1301 1SBL 137 001 R1410 1SBL 137 001 R1401 1SBL 156 001 R2110 1SBL 156 001 R2101 1SBL 157 001 R1210 1SBL 157 001 R1201 1SBL 157 001 R1310 1SBL 157 001 R1301 1SBL 157 001 R1410 1SBL 157 001 R1401 1SBL 176 001 R2110 1SBL 176 001 R2101 1SBL 177 001 R1210 1SBL 177 001 R1201 1SBL 177 001 R1310 1SBL 177 001 R1301 1SBL 177 001 R1410 1SBL 177 001 R1401 1SBL 236 001 R2100 1SBL 237 001 R1200 1SBL 237 001 R1300 1SBL 237 001 R1400 1SBL 276 001 R2100 1SBL 277 001 R1200 1SBL 277 001 R1300 1SBL 277 001 R1400 1SBL 296 001 R2100 1SBL 297 001 R1200 1SBL 297 001 R1300 1SBL 297 001 R1400 1 piece kg 0.310 0.310 0.270 0.270 0.270 0.270 0.310 0.310 0.310 0.310 0.270 0.270 0.270 0.270 0.310 0.310 0.310 0.310 0.270 0.270 0.270 0.270 0.310 0.310 0.350 0.310 0.310 0.350 0.350 0.310 0.310 0.350 0.350 0.310 0.310 0.350 AF09 ... AF38 3-pole Contactors - AF..Z Additional Coils AC / DC Operated - with Screw Terminals Catalogue Page 1SBC 101 072 S0201 4 to 18.5 kW 5 to 20 hp Application cULus CE AF09Z ... AF38Z contactors are used for controlling power circuits up to 690 V AC and 220 V DC. They are mainly used for controlling 3-phase motors, non-inductive or slightly inductive loads. Description – AF09Z ... AF38Z contactors include an electronic coil interface accepting a wide control voltage Uc min. ... Uc max and managing large control voltage variations. – AF..Z contactors cover control voltages comprised between 24...250 V 50/60 Hz or 12...250 V DC – AF..Z contactors allow direct control by PLC-output ≥ 24 V DC 500 mA and obtain a reduced holding coil consumption. AF..Z contactors withstand short dips and voltage interruptions (SEMI F47-0706 compliance) – AF..Z contactors have built-in surge protection and do not require additional surge suppressors – The built-in N.C. auxiliary contact is a mirror contact in compliance with annex F of IEC 60947-4-1. Ordering Details AF09Z-30-10 IEC UL/CSA Control voltage Rated power 400 V AC-3 kW 4 3-phase motor rating 480 V hp 5 Uc min. ... Uc max. 5.5 7.5 7.5 10 11 15 15 20 18.5 20 AF26Z-30-00 Auxiliary Type contacts fitted Order code Weight Pack(ing) V 50/60 Hz 24...60 24...60 48...130 48...130 100...250 100...250 24...60 24...60 48...130 48...130 100...250 100...250 24...60 24...60 48...130 48...130 100...250 100...250 24...60 48...130 100...250 24...60 48...130 100...250 24...60 48...130 100...250 V DC 12...20 12...20 20...60 20...60 48...130 48...130 100...250 100...250 12...20 12...20 20...60 20...60 48...130 48...130 100...250 100...250 12...20 12...20 20...60 20...60 48...130 48...130 100...250 100...250 12...20 20...60 48...130 100...250 12...20 20...60 48...130 100...250 12...20 20...60 48...130 100...250 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 0 0 0 0 0 0 0 0 0 0 0 AF09Z-30-10-20 AF09Z-30-01-20 AF09Z-30-10-21 AF09Z-30-01-21 AF09Z-30-10-22 AF09Z-30-01-22 AF09Z-30-10-23 AF09Z-30-01-23 AF12Z-30-10-20 AF12Z-30-01-20 AF12Z-30-10-21 AF12Z-30-01-21 AF12Z-30-10-22 AF12Z-30-01-22 AF12Z-30-10-23 AF12Z-30-01-23 AF16Z-30-10-20 AF16Z-30-01-20 AF16Z-30-10-21 AF16Z-30-01-21 AF16Z-30-10-22 AF16Z-30-01-22 AF16Z-30-10-23 AF16Z-30-01-23 AF26Z-30-00-20 AF26Z-30-00-21 AF26Z-30-00-22 AF26Z-30-00-23 AF30Z-30-00-20 AF30Z-30-00-21 AF30Z-30-00-22 AF30Z-30-00-23 AF38Z-30-00-20 AF38Z-30-00-21 AF38Z-30-00-22 AF38Z-30-00-23 1SBL 136 001 R2010 1SBL 136 001 R2001 1SBL 136 001 R2110 1SBL 136 001 R2101 1SBL 136 001 R2210 1SBL 136 001 R2201 1SBL 136 001 R2310 1SBL 136 001 R2301 1SBL 156 001 R2010 1SBL 156 001 R2001 1SBL 156 001 R2110 1SBL 156 001 R2101 1SBL 156 001 R2210 1SBL 156 001 R2201 1SBL 156 001 R2310 1SBL 156 001 R2301 1SBL 176 001 R2010 1SBL 176 001 R2001 1SBL 176 001 R2110 1SBL 176 001 R2101 1SBL 176 001 R2210 1SBL 176 001 R2201 1SBL 176 001 R2310 1SBL 176 001 R2301 1SBL 236 001 R2000 1SBL 236 001 R2100 1SBL 236 001 R2200 1SBL 236 001 R2300 1SBL 276 001 R2000 1SBL 276 001 R2100 1SBL 276 001 R2200 1SBL 276 001 R2300 1SBL 296 001 R2000 1SBL 296 001 R2100 1SBL 296 001 R2200 1SBL 296 001 R2300 1 piece kg 0.310 0.310 0.310 0.310 0.310 0.310 0.310 0.310 0.310 0.310 0.310 0.310 0.310 0.310 0.310 0.310 0.310 0.310 0.310 0.310 0.310 0.310 0.310 0.310 0.350 0.350 0.350 0.350 0.350 0.350 0.350 0.350 0.350 0.350 0.350 0.350 Note: Only AF..Z contactors with DC control voltage 12...20 V DC need to respect the connection polarities indicated close to the coil terminals: A1+ for the positive pole and A2- for the negative pole ABB | 5 AF09 ... AF38 3-pole Contactors Technical Data Catalogue Page 1SBC 101 108 S0201 Main Pole - Utilization Characteristics according to IEC Contactor types AF09 Standards Rated operational voltage Ue max. Rated frequency limits Conventional free-air thermal current Ith IEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1 690 V 25 ... 400 Hz acc. to IEC 60947-4-1, open contactors, θ ≤ 40 °C 35 A 6 mm² 35 A 6 mm² 35 A 6 mm² 25 A 25 A 22 A 4 mm² 28 A 28 A 24 A 6 mm² 30 A 30 A 26 A 6 mm² with conductor cross-sectional area AC-1 Utilization category for air temperature close to contactor Ie / AC-1 rated operational current Ue max. ≤ 690 V, 50/60 Hz θ ≤ 40 °C θ ≤ 60 °C θ ≤ 70 °C with conductor cross-sectional area AC-3 Utilization category for air temperature close to contactor θ ≤ 60 °C AF12 AF16 AF26 AF30 AF38 50 A 10 mm² 50 A 10 mm² 50 A 10 mm² 45 A 40 A 32 A 10 mm² 50 A 42 A 37 A 10 mm² 50 A 42 A 37 A 10 mm² 9A 12 A 18 A 9A 12 A 18 A 9A 12 A 18 A 9A 12 A 18 A 9.5 A 12.5 A 15 A 7A 9A 10.5 A 2.2 kW 3 kW 4 kW 4 kW 5.5 kW 7.5 kW 4 kW 5.5 kW 9 kW 4 kW 5.5 kW 9 kW 5.5 kW 7.5 kW 9 kW 5.5 kW 7.5 kW 9 kW 10 x Ie AC-3 acc. to IEC 60947-4-1 8 x Ie AC-3 acc. to IEC 60947-4-1 26 A 26 A 26 A 26 A 23 A 17 A 6.5 kW 11 kW 11 kW 15 kW 15 kW 15 kW 33 A 32 A 32 A 32 A 28 A 21 A 9 kW 15 kW 15 kW 18.5 kW 18.5 kW 18.5 kW 40 A 38 A 38 A 38 A 33 A 24 A 11 kW 18.5 kW 18.5 kW 22 kW 22 kW 22 kW 12 A 5.5 kW 16 A 7.5 kW 22 A 11 kW 30 A 15 kW 40 A 20 kW 50 A 25 kW 25 A 300 A 150 A 80 A 60 A 35 A 250 A 106 A 0.8 W 0.1 W 600 cycles/h 1200 cycles/h 300 cycles/h 32 A 300 A 150 A 80 A 60 A 35 A 250 A 106 A 1W 0.2 W 32 A 300 A 150 A 80 A 60 A 35 A 250 A 106 A 1.2 W 0.35 W 50 A 700 A 350 A 225 A 150 A 50 A 500 A 200 A 1.8 W 0.6 W 63 A 700 A 350 A 225 A 150 A 50 A 500 A 200 A 2.4 W 0.9 W 63 A 700 A 350 A 225 A 150 A 50 A 500 A 200 A 2.4 W 1.3 W (for 1500 r.p.m., 50 Hz or 1800 r.p.m., 60 Hz, 3-phase motors) Ie / AC-3 max. rated operational current 3-phase motors M 3 AC-3 rated operational power M 3 1500 r.p.m. 50 Hz 1800 r.p.m. 60 Hz 3-phase motors 220-230-240 V 380-400 V 415 V 440 V 500 V 690 V 220-230-240 V 380-400 V 415 V 440 V 500 V 690 V Rated making capacity AC-3 Rated breaking capacity AC-3 AC-8a Utilization category (without thermal overload relay - Ue 400 V - θ ≤ 40 °C) Ie / AC-8a rated operational current AC-8a rated operational power Short-circuit protection for contactors without thermal O/L relay - Motor protection excluded Ue ≤ 500 V AC - gG type fuse Rated short-time withstand current Icw at 40 °C ambient temperature, in free air from a cold state Maximum breaking capacity cos φ = 0.45 Heat dissipation per pole Max. electrical switching frequency 6 | ABB 1s 10 s 30 s 1 min 15 min at 440 V at 690 V Ie / AC-1 Ie / AC-3 AC-1 AC-3 AC-2, AC-4 150 cycles/h AF09 ... AF38 3-pole Contactors Technical Data Catalogue Page 1SBC 101 108 S0201 Built-in Auxiliary Contacts according to IEC AF09 Contactor types Rated operational voltage Ue max. Conventional free air thermal current Ith - θ ≤ 40 °C Rated frequency limits Rated operational current Ie / AC-15 acc. to IEC 60947-5-1 24-127 V 50/60 Hz 220-240 V 50/60 Hz 400-440 V 50/60 Hz 500 V 50/60 Hz 690 V 50/60 Hz Making capacity AC-15 Breaking capacity AC-15 Rated operational current Ie / DC-13 acc. to IEC 60947-5-1 Short-circuit protection gG type fuse Rated short-time withstand current Icw 24 V DC 48 V DC 72 V DC 110 V DC 125 V DC 220 V DC 250 V DC 400 V DC 500 V DC 600 V DC for 1.0 s for 0.1 s Minimum switching capacity with failure rate acc. to IEC 60947-5-4 Non-overlapping time between N.O. and N.C. contacts Heat dissipation per pole at 6 A Max. electrical switching frequency AF12 AF16 AF26 AF30 AF38 690 V 16 A 25 ... 400 Hz AC-15 DC-13 6A 4A 3A 2A 2A 10 x Ie AC-15 acc. to IEC 60947-5-1 10 x Ie AC-15 acc. to IEC 60947-5-1 6 A / 144 W 2.8 A / 134 W 1 A / 72 W 0.55 A / 60 W 0.55 A / 69 W 0.27 A / 60 W 0.27 A / 68 W 0.15 A / 60 W 0.13 A / 65 W 0.1 A / 60 W 10 A 100 A 140 A 12 V / 3 mA 10-7 ≥ 2 ms 0.1 W 1200 cycles/h 900 cycles/h ABB | 7 AF09 ... AF38 3-pole Contactors Technical Data Catalogue Page 1SBC 101 108 S0201 Main Pole - Utilization Characteristics according to UL / NEMA / CSA Contactor types AF09 Standards Rated operational voltage Ue max. NEMA size NEMA continuous amp rating NEMA maximum H.P. ratings 1-phase, 60 Hz UL 508, CSA C22.2 N°14 600 V 00 0 9A 18 A 1/3 hp 1 hp 1 hp 2 hp 1-1/2 hp 3 hp 1-1/2 hp 3 hp 2 hp 5 hp 2 hp 5 hp NEMA maximum H.P. ratings 3-phase, 60 Hz UL General use rating 600 V AC With conductor cross-sectional area 80 V DC - 1-pole With conductor cross-sectional area UL maximum 1-phase motor rating Amp-rating Motor power UL maximum 3-phase motor rating Amp-rating Motor power (for 1500 r.p.m., 50 Hz or 1800 r.p.m., 60 Hz 3-phase motors) thermal current 115 V AC 230 V AC 200 V AC 230 V AC 460 V AC 575 V AC 120 V AC 240 V AC 120 V AC 240 V AC 200-208 V AC 220-240 V AC 440-480 V AC 550-600 V AC 200-208 V AC 220-240 V AC 440-480 V AC 550-600 V AC AF12 AF16 AF26 AF30 AF38 - 1 27 A 2 hp 3 hp 7-1/2 hp 7-1/2 hp 10 hp 10 hp - - 25 A AWG 10 25 A AWG 10 28 A AWG 10 28 A AWG 10 30 A AWG 10 30 A AWG 10 45 A AWG 8 45 A AWG 8 50 A AWG 8 50 A AWG 8 50 A AWG 8 50 A AWG 8 13.8 A 10 A 3/4 hp 1-1/2 hp 16 A 12 A 1 hp 2 hp 20 A 17 A 1-1/2 hp 3 hp 24 A 17 A 2 hp 3 hp 24 A 28 A 2 hp 5 hp 24 A 28 A 2 hp 5 hp 7.8 A 6.8 A 7.6 A 9A 2 hp 2 hp 5 hp 7.5 hp 11 A 9.6 A 11 A 11 A 3 hp 3 hp 7.5 hp 10 hp 17.5 A 15.2 A 14 A 17 A 5 hp 5 hp 10 hp 15 hp 25.3 A 22 A 21 A 22 A 7.5 hp 7.5 hp 15 hp 20 hp 32.2 A 28 A 27 A 32.2 A 28 A 27 A 60 A NTD 60 A 60 A AF16 (1) (1) 10 hp 10 hp 20 hp 10 hp 10 hp 20 hp (1) (1) 150 A 150 A 150 A AF26 AF30 AF38 Short-circuit protection for contactors without thermal O/L relay - Motor protection excluded Fuse rating Fuse type, 600 V Max. electrical switching frequency for general use for motor use Mechanical durability Number of operating cycles Max. switching frequency 600 cycles/h 1200 cycles/h 10 millions operating cycles 3600 cycles/h (1) On request Built-in Auxiliary Contacts according to UL / CSA Contactor types AF09 Max. rated operational voltage Ue max. Pilot duty AC thermal rated current AC maximum volt-ampere making AC maximum volt-ampere breaking DC thermal rated current DC maximum volt-ampere making-breaking 600 V AC, 600 V DC A600, Q600 10 A 7200 VA 720 VA 2.5 A 69 VA 8 | ABB AF12 AF09 ... AF38 3-pole Contactors Technical Data Catalogue Page 1SBC 101 108 S0201 General Technical Data AF09 Contactor types Rated insulation voltage Ui AF12 AF16 AF26 AF30 AF38 690 V 600 V 6 kV Devices complying with IEC 60947-1 / EN 60947-1 - Environment A acc. to IEC 60947-4-1 acc. to UL / CSA Rated impulse withstand voltage Uimp. Electromagnetic compatibility Ambient air temperature close to contactor Operation fitted with thermal overload relay without thermal overload relay Storage Climatic withstand Operating altitude Mechanical durability Number of operating cycles Max. switching frequency Shock withstand -40 ... +70 °C -60 ... +80 °C Category B according to IEC 60947-1 Annex Q ≤ 3000 m 10 millions operating cycles 3600 cycles/h acc. IEC 60068-2-27 and EN 60068-2-27 Mounting position 1 Closed or open position C1 A A B1 B2 C2 Shock direction A B1 B2 C1 C2 Vibration withstand acc. to IEC 60068-2-6 1/2 sinusoidal shock for 11 ms: no change in contact position 30 g 25 g Closed position / 5 g Open position 15 g 25 g 25 g 5 ... 300 Hz 4 g Closed position / 2 g Open position Magnet System Characteristics AF09 Contactor types Coil operating limits AF12 AF16 AF26 AF30 AF38 AC supply at θ ≤ 60 °C 0.85 x Uc min ... 1.1 x Uc max at θ ≤ 70 °C 0.85 x Uc min ... Uc max DC supply at θ ≤ 60 °C 0.85 x Uc min ... 1.1 x Uc max at θ ≤ 70 °C (AF) 0.85 x Uc min ... Uc max - (AF..Z) 0.85 x Uc min ... 1.1 x Uc max 24 ... 500 V AC (AF) 50 VA - (AF..Z) 16 VA (AF) 2.2 VA / 2 W - (AF..Z) 1.7 VA / 1.5 W 12 ... 500 V DC (AF) 50 W - (AF..Z) 12 ... 16 W (AF) 2 W - (AF..Z) 1.7 W (AF..Z) ≥ 500 mA 24 V DC ≤ 60 % Uc min (AF..Z) conditions of use on request (AF..Z) 22 ms average for Uc = 24 ... 250 V 50/60Hz acc. to IEC 60947-4-1 AC control voltage 50/60 Hz Rated control circuit voltage Uc Average pull-in value Coil consumption DC control voltage Rated control circuit voltage Uc Average pull-in value Coil consumption Average holding value Average holding value PLC-Output control Drop-out voltage in % of Uc min. Voltage sag immunity according to SEMI F47-0706 Dips withstand (level 0% according to IEC 61000-4-11) -20 °C ≤ θ ≤ +60 °C Operating time N.O. contact closing 40 ... 95 ms between coil energization and: N.C. contact opening 38 ... 90 ms N.O. contact opening 11 ... 95 ms between coil de-energization and: N.C. contact closing 13 ... 98 ms Mounting Characteristics Contactor types AF09 Mounting positions AF12 Pos. 2 +30° AF16 AF26 AF30 AF38 -30° Pos. 4 Pos. 3 Pos. 1 Mounting distances Fixing on rail according to IEC 60715, EN 60715 by screws (not supplied) Pos. 1 ± 30° Pos. 5 Max. N.C. built-in and add-on N.C. auxiliary contacts: see accessory fitting details for a 3-pole contactor AF09 ... AF38 The contactors can be assembled side by side. 35 x 7.5 mm or 35 x 15 mm 2 x M4 screws placed diagonally ABB | 9 AF09 ... AF38 3-pole Contactors Technical Data Catalogue Page 1SBC 101 108 S0201 Connecting Characteristics AF09 Contactor types AF12 AF16 AF26 AF30 Main terminals Screw terminals with cable clamp Connecting capacity (min. ... max.) Main conductors (poles) Rigid solid (≤ 4 mm²) stranded (≥ 6 mm²) Flexible with non insulated ferrule Flexible with insulated ferrule L 6 Bars or lugs Capacity according to UL/CSA Stripping length Auxiliary conductors (built-in auxiliary terminals + coil terminals) Rigid solid Flexible with non insulated ferrule Flexible with insulated ferrule L 6 Bars or lugs Capacity according to UL/CSA Stripping length Degree of protection 1x 2x 1x 2x 1x 2x L< 1 or 2 x 1 ... 6 mm² 1 ... 6 mm² 0.75 ... 6 mm² 0.75 ... 6 mm² 0.75 ... 4 mm² 0.75 ... 2.5 mm² 9.6 mm 2.5 ... 10 mm² 2.5 ... 10 mm² 1.5 ... 10 mm² 1.5 ... 10 mm² 1.5 ... 10 mm² 1.5 ... 4 mm² 12.5 mm AWG 16 ... 10 10 mm AWG 14 ... 8 14 mm 1x 2x 1 ... 2.5 mm² 1 ... 2.5 mm² 1x 2x 1x 2x L< 0.75 ... 2.5 mm² 0.75 ... 2.5 mm² 0.75 ... 2.5 mm² 0.75 ... 1.5 mm² 8 mm 1 or 2 x AWG 18 ... 14 10 mm acc. to IEC 60947-1 / EN 60947-1 and IEC 60529 / EN 60529 Main terminals Coil terminals Built-in auxiliary terminals Screw terminals Main terminals Coil terminals Built-in auxiliary terminals Screwdriver type Tightening torque Main pole terminals Coil terminals Built-in auxiliary terminals 10 | ABB IP20 IP20 IP20 (delivered in open position, screws of unused terminals must be tightened) M3.5 M4 M3.5 M3.5 Flat Ø5.5 / Pozidriv 2 1.5 Nm / 13 lb.in 1.2 Nm / 11 lb.in 1.2 Nm / 11 lb.in 2.5 Nm / 22 lb.in AF38 AF09 ... AF38 3-pole Contactors Main Accessories Catalogue Page 1SBC 101 066 S0201 Accessory fitting details for a 3-pole contactor AF09 ... AF38 Many configurations of accessories are possible depending on whether these are front-mounted or side-mounted. Contactor types Main poles Built-in auxiliary contacts Front-mounted accessories Side-mounted accessories Auxiliary contact blocks Electrical and mechanical interlock set Auxiliary contact blocks (between 2 contactors) 1-pole CA4 Left side 1-pole CC4 2-pole CAT4-11 4-pole CA4 Right side 2-pole CAL4-11 VEM4 Max. N.C. built-in and add-on N.C. auxiliary contacts: 4 N.C. max. on positions 1, 2, 3, 4 and 3 N.C. max. on positions 1 ±30°, 5 3 0 AF09 ... AF16 0 1 AF09 ... AF16 3 0 1 0 AF26 ... AF38 3 0 0 0 4 max. or 1 or 1 – + 1 – 2 max. – – – + 1 + 1 or 1 3 max. – – + 1 + 1 4 max. or 1 or 1 – + 1 – 2 max. or 1 – – + 1 + 1 3 max. – – + 1 + 1 or 1 Mounting positions Pos. 2 +30° -30° Pos. 4 Pos. 3 Pos. 1 Pos. 1 ± 30° Pos. 5 Protection against overloads with thermal or electronic overload relays The addition of an overload relay on the contactor does not prevent fitting of many other accessories as shown below. Contactor types Overload relays - direct mounting - no kit required AF09 ... AF38 TF42 thermal overload relay AF09 ... AF38 EF19 electronic overload relay AF26 ... AF38 EF45 electronic overload relay Contactors and main accessories (other accessories available) VEM4 mechanical and electrical interlock set including: – VM4 mechanical interlock unit including 2 fixing clips – VE4 electrical interlock block with A2-A2 connection AF contactor (without top mounted coil terminal block) AF contactor Fixing clips A2 A2 AF contactor 2-pole CAT4-11 VM4 1-pole CA4, CC4 4-pole CA4 2-pole CAL4-11 1-pole CA4, CC4 VE4 2-pole CAL4-11 1-pole CA4, CC4 TF42 EF.. TF42 EF.. ABB | 11 Auxiliary Contact Blocks Accessories for AF09 ... AF38 3-pole Contactors Catalogue Page 1SBC 101 135 S0201 Application The auxiliary contact blocks are used for the operation of auxiliary circuits and control circuits. Description CA4-10 Types of auxiliary contact blocks for standard industrial environments: –– CA4 1 or 4-pole block, front-mounted, instantaneous with N.O., N.C. contacts –– CC4 1-pole block, front-mounted, with N.O. leading contact or N.C. lagging contact –– CAT4 2-pole block, front-mounted, instantaneous N.O. + N.C. contacts with A1 / A2 coil terminal connection on front face –– CAL4 2-pole block instantaneous N.O. + N.C. contacts clipped onto the right and/or left side of the contactors. Select the type of 2 or 4-pole auxiliary contact blocks CAT4 or CA4-..E, CA 4-..M or CA 4-..U, according to the contactor type for compliance with the standard requirements (see terminal and marking positioning). The auxiliary contact blocks are equipped with screw type connecting terminals delivered open, protected against accidental direct contact and bear the corresponding function marking. Fitting Details - For each contactor refer to "Accessory Fitting Details" table. CA4-22M Ordering Details For contactors Auxiliary contacts Type Order code Pack(ing) Weight pieces kg (1 pce) Front-mounted instantaneous auxiliary contact blocks AF09 ... AF38 AF09 ... AF16..-30-10 CAL4-11 AF26 ... AF38..-30-00 AF09 ... AF16..-30-01 CAT4-11E 1 1 0 0 2 3 1 0 2 3 4 0 2 3 4 0 0 1 1 2 1 3 4 2 1 0 4 2 1 0 - - CA4-10 CA4-10-T CA4-01 CA4-01-T CA4-22M CA4-31M CA4-13M CA4-04M CA4-22E CA4-31E CA4-40E CA4-04E CA4-22U CA4-31U CA4-40U 1SBN 010 110 R1010 1SBN 010 110 T1010 1SBN 010 110 R1001 1SBN 010 110 T1001 1SBN 010 140 R1122 1SBN 010 140 R1131 1SBN 010 140 R1113 1SBN 010 140 R1104 1SBN 010 140 R1022 1SBN 010 140 R1031 1SBN 010 140 R1040 1SBN 010 140 R1004 1SBN 010 140 R1322 1SBN 010 140 R1331 1SBN 010 140 R1340 1 10 1 10 1 1 1 1 1 1 1 1 1 1 1 0.014 0.014 0.014 0.014 0.055 0.055 0.055 0.055 0.055 0.055 0.055 0.055 0.055 0.055 0.055 Front-mounted auxiliary contact blocks with N.O. leading contact and N.C. lagging contact AF09 ... AF38 - - - 1 0 0 1 CC4-10 CC4-01 1SBN 010 111 R1010 1SBN 010 111 R1001 1 1 0.014 0.014 1SBN 010 120 R1011 1SBN 010 120 T1011 1 10 0.040 0.040 1 1 1 0.040 0.040 0.040 Side-mounted instantaneous auxiliary contact blocks AF09 ... AF38 1 1 1 1 - - - CAL4-11 CAL4-11-T Front-mounted instantaneous auxiliary contact and A1/A2 coil terminal blocks AF09 ... AF16..-30-10 AF26 ... AF38..-30-00 AF09 ... AF16..-30-01 1 1 1 1 1 1 - - - - CAT4-11M CAT4-11E CAT4-11U Note: CAT4 not fittable on AF..Z contactors with DC control voltage 12...20 V DC. 12 | ABB 1SBN 010 151 R1111 1SBN 010 151 R1011 1SBN 010 151 R1311 Auxiliary Contact Blocks Accessories for AF09 ... AF38 3-pole Contactors Catalogue Page 1SBC 101 136 S0201 Technical Data 1-pole CA4, 1-pole CC4, 4-pole CA4, 2-pole CAT4, 2-pole CAL4 Types Contact Utilization Characteristics according to IEC Standards Rated insulation voltage Ui acc. to IEC 60947-5-1 Rated impulse withstand voltage Uimp Rated operational voltage Ue max. Conventional thermal current Ith - θ ≤ 40 °C Rated frequency limits Rated operational current Ie / AC-15 acc. to IEC 60947-5-1 24-127 V 50/60 Hz 220-240 V 50/60 Hz 400-440 V 50/60 Hz 500 V 50/60 Hz 690 V 50/60 Hz Making capacity acc. to IEC 60947-5-1 Breaking capacity acc. to IEC 60947-5-1 Rated operational current Ie / DC-13 acc. to IEC 60947-5-1 Short-circuit protection gG type fuse Rated short-time withstand current Icw θ = 40 °C 24 V DC 48 V DC 72 V DC 110 V DC 125 V DC 220 V DC 250 V DC 400 V DC 500 V DC 600 V DC for 1.0 s for 0.1 s Minimum switching capacity with failure rate acc. to IEC 60947-5-4 Heat dissipation per pole at 6 A Mechanical durability Number of operating cycles Max. switching frequency Max. electrical switching frequency for AC-15 for DC-13 IEC 60947-5-1 and EN 60947-5-1 690 V 6 kV 24 ... 690 V 16 A 25 ... 400 Hz 6A 4A 3A 2A 2A 10 x Ie AC-15 acc. to IEC 60947-5-1 10 x Ie AC-15 acc. to IEC 60947-5-1 6 A / 144 W 2.8 A / 134 W 1 A / 72 W 0.55 A / 60 W 0.55 A / 69 W 0.27 A / 60 W 0.27 A / 68 W 0.15 A / 60 W 0.13 A / 65 W 0.1 A / 60 W 10 A 100 A 140 A 12 V / 3 mA 10-7 0.1 W 10 millions operating cycles 3600 cycles/h 1200 cycles/h 900 cycles/h Contact Utilization Characteristics according to UL / CSA UL 508, CSA C22.2 N°14 600 V 600 V AC, 600 V DC A600, Q600 10 A 7200 VA 720 VA 2.5 A 69 VA Standards Rated insulation voltage Ui Max. rated voltage Pilot duty AC thermal rated current AC maximum volt-ampere making AC maximum volt-ampere breaking DC thermal rated current DC maximum volt-ampere making-breaking Connecting Characteristics Screw terminals All terminals Connecting capacity (min. ... max.) Rigid solid Flexible with non insulated ferrule Flexible with insulated ferrule L 6 Bars or lugs Capacity acc. to UL/CSA Stripping length Degree of protection acc. to IEC 60947-1 / EN 60947-1 and IEC 60529 / EN 60529 Screwdriver type Tightening torque (delivered in open position, screws of unused terminals must be tightened) M3.5 1x 2x 1x 2x 1x 2x L< 1 or 2 x 1 ... 2.5 mm² 1 ... 2.5 mm² 0.75 ... 2.5 mm² 0.75 ... 2.5 mm² 0.75 ... 2.5 mm² 0.75 ... 1.5 mm² 8 mm AWG 18 ... 14 10 mm IP20 Flat Ø5.5 / Pozidriv 2 1.2 Nm / 11 lb.in ABB | 13 Connexion Accessories for Starting Solutions Accessories for AF09 ... AF38 3-pole Contactors Catalogue Page 1SBC 101 137 S0201 Connecting links with manual motor starters Description The BEA..-4 connecting links are used to connect AF09 ... AF38 contactors with the MS116 or MS132 manual motor starters. The BEA..-4 insulated 3-pole connecting links ensure the electrical and mechanical connection between the contactor and the associated manual motor starter. Ordering Details For contactors Type Order code Pack(ing) Weight pieces BEA16-4 kg (1 pce) AF09 ... AF16 with MS116 and MS132 AF26 ... AF38 with MS132-12 ... MS132-32 BEA16-4 BEA38-4 1SBN 081 306 T1000 1SBN 082 306 T2000 10 10 0.025 0.030 Connection sets for reversing contactors Description A1 A2 1 3 5 1 3 5 2 4 6 2 4 6 A1 A2 BER16-4 and BER38-4 connection sets between the main poles of two 3-pole contactors mounted side by side. The connection sets are made up of 1 upstream and 1 downstream connections: insulated, solid copper bars. Ordering Details For contactors Type Order code Pack(ing) Weight pieces kg (1 pce) AF09 ... AF16 AF26 ... AF38 BER16-4 BER38-4 1SBN 081 311 R1000 1SBN 082 311 R1000 1 1 0.045 0.100 Connection sets for Star-Delta starting BER16-4 A1 A2 Description 1 3 5 2 4 6 A1 A2 1 3 5 2 4 6 A1 A2 1 3 5 2 4 6 BEY16-4 and BEY38-4 connection sets between the main poles of the Line, Delta and Star contactors of a StarDelta starter. The connection sets are made up of: — Line contactor / Delta contactor: upstream phase-to-phase connection — Delta contactor / Star contactor: downstream connection in parallel — Star contactor: Star point upstream. Ordering Details BEY16-4 14 | ABB For Line, Delta and Star contactors Interlock unit between Delta & Star contactors Type AF09 ... AF16 AF26 ... AF38 With or without VM4 or VEM4 BEY16-4 BEY38-4 Order code Pack(ing) Weight pieces kg (1 pce) 1SBN 081 313 R2000 1SBN 082 713 R2000 1 1 0.050 0.110 Interlocks Accessories for AF09 ... AF38 3-pole Contactors Catalogue Page 1SBC 101 146 S0201 Mechanical interlock unit Description VM4 mechanical interlock unit for the interlocking of two AF contactors. When mounted between two contactors without additional width, the VM4 mechanical interlock unit prevents one of the contactors from closing as long as the other contactor is closed. The mechanical interlock unit includes 2 fixing clips (BB4). Ordering Details For contactors Type Order code Pack(ing) Weight pieces VM4 kg (1 pce) AF09 ... AF38 VM4 1SBN 030 105 T1000 10 0.005 Mechanical and electrical interlock set Description VEM4 mechanical and electrical interlock set for the interlocking of two AF contactors. VEM4 set includes a mechanical interlock unit VM4 with 2 fixing clips (BB4) and a VE4 electrical interlock block with A2-A2 connection. Fixing the electrical interlock block to the contactor front face connects the 2 built-in N.C. interlocking contacts with the two coils. VE4 block must be used with A2-A2 connection to respect the electrical connection diagram. Ordering Details For contactors VEM4 01 NC Auxiliary Type contacts Order code Pack(ing) Weight pieces 1SBN 030 111 R1000 1 Order code Pack(ing) Weight 01NC kg (1 pce) KM1 A2 KM2 VEM4 A2 AF09 .. AF16 AF26 .. AF38 1 1 VEM4 0.035 Note: VEM4 not fittable on AF..Z contactors with DC control voltage 12...20 V DC. Fixing clips Ordering Details For contactors Type pieces kg (1 pce) BB4 AF09 ... AF38 BB4 1SBN 110 120 W1000 50 0.002 ABB | 15 Interlocks Accessories for AF09 ... AF38 3-pole Contactors Technical Data VM4 Interlock types Mechanical durability Number of operating cycles 5 millions operating cycles Max. switching frequency 1800 cycles/h VEM4 Interlock types Contact Utilization Characteristics according to IEC Standards IEC 60947-5-1 and EN 60947-5-1 Rated insulation voltage Ui acc. to IEC 60947-5-1 690 V Rated impulse withstand voltage Uimp 6 kV Rated control circuit voltage Uc AC 50/60 Hz control voltage DC control voltage Conventional thermal current Ith - θ ≤ 40 °C Mechanical and electrical durability 24 ... 500 V AC 20 ... 500 V DC 16 A Number of operating cycles 5 millions operating cycles Max. mechanical switching frequency 1800 cycles/h Max. electrical switching frequency 1200 cycles/h Contact Utilization Characteristics according to UL / CSA Standards UL 508, CSA C22.2 N°14 Max. rated voltage 500 V AC, 500 V DC Connecting Characteristics Screw terminals All terminals M3.5 Connecting capacity (min. ... max.) Rigid Solid Flexible with non insulated ferrule Flexible with insulated ferrule L 6 Bars or lugs Capacity according to UL/CSA 1x 1 ... 2.5 mm² 2x 1 ... 2.5 mm² 1x 0.75 ... 2.5 mm² 2x 0.75 ... 2.5 mm² 1x 0.75 ... 2.5 mm² 2x 0.75 ... 1.5 mm² L< 8 mm 1 or 2 x AWG 18 ... 14 Stripping length Degree of protection 10 mm acc. to IEC 60947-1 / EN 60947-1 and IEC 60529 / EN 60529 IP20 Screwdriver type Flat Ø5.5 / Pozidriv 2 Tightening torque 1.2 Nm / 11 lb.in 16 | ABB Catalogue Page 1SBC 101 146 S0201 Other Accessories Accessories for AF09 ... AF38 3-pole Contactors Catalogue Page 1SBC 101 147 S0201 Additional coil terminal block Description Additional coil terminal block for a bottom access to the coil terminals of contactors or contactor relays. Ordering Details For contactors Type Order code Pack(ing) Weight pieces kg (1 pce) LDC4 AF09 ... AF38 LDC4 1SBN 070 156 T1000 10 0.010 Protective covers Description Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact. Ordering Details For contactors Type Order code Pack(ing) Weight pieces kg (1 pce) BX4 All 1-stack contactors BX4 For 4-pole CA4 and 2-pole CAT4 auxiliary contact BX4-CA blocks 1SBN 110 108 T1000 1SBN 110 109 W1000 10 50 0.006 0.001 BX4-CA Function markers Description Box of 16 blank cards (16 markers by card) printable on HTP500 thermal transfer printer and AMS 500 marking table to identify your contactors, overload relays or manual motor starters. Marker dimensions: 7 x 20 mm (.276" x .787") Ordering Details For contactors Type Order code Pack(ing) Weight pieces kg (1 pce) BA4 Marker card AMS 500 support plate for 8 BA4 HTP500 support plate BA4 SPRC 1 HTP500-BA4 1SNA 235 156 R2700 1SNA 360 010 R1500 1SNA 235 712 R2400 16 1 1 0.011 0.220 0.290 ABB | 17 AF09 ... AF38 3-pole Contactors Terminal Marking and Positioning Catalogue Page 1SBC 101 113 S0201 Standard devices without addition of auxiliary contacts A1 A2 A1 A2 A1 A2 1L1 3L2 5L3 13 1L1 3L2 5L3 NO 21 3L2 1L1 A1 1L1 3L2 5L3 13 NO A1 1L1 3L2 5L3 A2 2T1 4T2 6T3 NO 14 A2 2T1 4T2 6T3 5L3 NC AF09...AF16..-30-10 NO 2T1 4T2 6T3 AF26...AF38..-30-00 A1 1L1 3L2 5L3 21 NC A2 2T1 4T2 6T3 NC 22 NC 14 2T1 4T2 6T3 A1 A2 2T1 22 A1 A2 AF09...AF16..-30-10 4T2 6T3 A1 A2 AF09...AF16..-30-01 AF26...AF38..-30-00 AF09...AF16..-30-01 Other possible contact combinations with auxiliary contacts added by the user A1 A2 1L1 3L2 5L3 1L1 3L2 5L3 NO 21 A1 A2 A1 A2 13 13 1L1 NO 2- = NC 22 + 2- NO 2T1 4T2 6T3 3L2 -1 13 21 NC NO NC -2 14 22 A1 A2 5L3 14 2T1 A1 A2 4T2 6T3 13 1L1 3L2 5L3 NO 1L1 3L2 5L3 NO + NC NO NC NC NO 2T1 4T2 6T3 14 2T1 4T2 6T3 Combination 21 = AF09...AF16..-30-10 + A1 A2 NO NO 13X 21X = NC NO 2T1 4T2 6T3 5L3 13 NO 21 NC A2 2T1 4T2 6T3 NO 14 NC 22 + NC Combination 11 -2 4T2 6T3 A1 A2 13 1L1 3L2 5L3 NO CAT4-11M 14 A1 1L1 3L2 5L3 13 NO 21 NC 33 NO A2 2T1 4T2 6T3 NO 14 NC 22 NO 34 13 NO = 21 31 43 53 + NC NC NO NO 22 32 44 54 Combination 21 A1 1L1 3L2 5L3 13 NO 21 NC 31 NC 43 53 NO NO A2 2T1 4T2 6T3 NO 14 NC 22 NC 32 NO NO 44 54 NO 2T1 4T2 6T3 14 A1 A2 Combination 32 = AF09...AF16..-30-10 + CA4-22M Combination 32 A1 A2 13 NC 22X 14X 3L2 A1 A2 NO A1 A2 13X 21X NO -1 -4 22 32 44 54 NO 14 1L1 3L2 5L3 + 21 31 43 53 22 34 A2 NO NO -3 NO A1 21 33 22 34 A2 2T1 4T2 6T3 2- 1L1 Combination 11 = AF26...AF38..-30-00 + CA4-10 + CA4-01 13 = NO 1- 2T1 A1 A2 NC 2- = A1 A2 Combination 11 = AF09...AF16..-30-10 + CA4-01 A1 21 33 1- A1 5L3 NO 2T1 4T2 6T3 14 A1 A2 1L1 3L2 5L3 3L2 1L1 NC NC NO 22X 14X 14 NO 1L1 3L2 5L3 + A1 A2 Combination 21 13 NO 2T1 4T2 6T3 CAL4-11 + 1L1 3L2 5L3 13 13X 21X NO NO NC A2 2T1 4T2 6T3 NO NO NC 14 14X 22X 14 A1 A2 = A1 NO AF09...AF16..-30-10 Combination 21 Note: Only AF..Z contactor with DC control voltage 12...20 V DC need to respect the connection polarities indicated close to the coil terminals: A1+ for the positive pole and A2- for the negative pole 18 | ABB Add-on Auxiliary Contacts Terminal Marking and Positioning Catalogue Page 1SBC 101 113 S0201 1-pole auxiliary contacts -1 -5 -3 NO NC -4 -2 CA4-01 -7 NO NC -8 -6 CA4-10 CC4-01 CC4-10 2-pole auxiliary contacts 31X 43X CAL4-11 (Left side-mounted) 32X / NO 44X / 21X 44X 22X / 43X / NC NC 21 CAL4-11 (Right side-mounted) 33 NC 13X 32X 14X / 31X / 22X 21X / NO 14X 13X / 13 NO 22 NO 34 21 NC 14 CAT4-11M CAT4-11E -3 NO 22 -1 NC -4 -2 CAT4-11U 4-pole auxiliary contacts 13 NO 14 23 NO 33 NO 24 43 NO 34 44 CA4-40E 13 NO 14 21 NC 22 13 14 31 41 NC NC NC 22 32 42 53 NO 54 CA4-13M 33 NO 34 43 NO 44 CA4-31E NO 21 21 NC 22 33 NO 43 44 53 NO 54 CA4-31M 21 31 NC NC 22 32 43 NO 44 CA4-22E 21 31 NC NC 22 32 3 NO 4 3 NO 4 4 3 NO 4 1 NC 2 3 NO 4 3 NO 4 CA4-31U 43 NO 44 53 NO 54 CA4-22M 3 NO 4 1 1 NC NC 2 2 3 NO 4 CA4-22U 11 21 31 41 21 31 41 51 NC NC NC NC NC NC NC NC 12 22 32 42 22 32 42 52 CA4-04E 4 3 NO CA4-40U NO 34 3 NO CA4-04M ABB | 19 AF09 ... AF16 3-pole Contactors AC / DC Operated - with Screw Terminals Catalogue Page 1SBC 101 091 S0201 Dimensions mm, inches 77 3.03" 10 0.39" ø 4.2 0.17" 70 2.76" 2x M4 8-32 UNC 10 0.39" 5 0.20" 5 0.20" 5.5 0.22" 35 1.38" 2x M4 8-32 UNC 70 2.76" 5.5 0.22" 35 1.38" ø 4.2 0.17" 60 2.36" 35 mm EN/IEC 60715 6 0.24" 35 mm EN/IEC 60715 80 3.15" 6 0.24" 80 3.15" 5.5 0.22" 60 2.36" 71 2.80" 5.5 0.22" 5 0.20" 77 3.03" 2.80" 45711.77" 45 1.77" 5 0.20" AF09, AF12, AF16 AF09, AF12, AF16 110.5 4.35" 71 2.80" 45 1.77" 77 3.03" 10 0.39" 12 0.47" 71 2.80" 45 1.77" 80 3.15" 5.5 0.22" 35 mm EN/IEC 60715 6 0.24" 5.5 0.22" 43 1.69" 80 3.15" 35 mm EN/IEC 60715 6 0.24" 5.5 0.22" 5.5 0.22" 10 0.39" AF09, AF12, AF16 + CA4, CC4 1-pole auxiliary contact block AF09, AF12, AF16 + CAL4-11 2-pole auxiliary contact block 102.5 4.04" 110.5 4.35" 71 2.80" 10 0.39" 45 1.77" AF09, AF12, AF16 + CA4 4-pole auxiliary contact block 102.5 4.04" ø 4.2 0.17" AF09, AF12, AF16 + VEM4 mechanical and electrical interlock set Note: contactor lateral distance to grounded component 2 mm 0.08" min. 20 | ABB ø 0.17" 5 4.2 0.20" 2x M4 8-32 UNC 70 2.76" 5.5 0.22" 80 3.15" 2 x M4 8-32 UNC 5 0.20" 80 3.15" 70 2.76" 5.5 0.22" 10 0.39" 5.5 0.22" 60 2.36" 35 mm EN/IEC 60715 35 mm EN/IEC 60715 91.5 3.60" 91.5 3.60" 5.5 0.22" 102.5 4.04" 0.39" 71102.80" 5 0.20" 71 2.80" 60 2.36" 43 1.69" 90 3.54" 5.5 0.22" AF09, AF12, AF16 + CAT4 2-pole auxiliary contact and coil terminal block 43 1.69" 90 3.54" 35 mm EN/IEC 60715 5.5 0.22" 10 0.39" 5.5 0.22" 80 3.15" 43 1.69" 80 3.15" 35 mm EN/IEC 60715 6 0.24" 5.5 0.22" 5 0.20" AF09, AF12, AF16 + VEM4 mechanical and electrical interlock set 43 1.69" 71 2.80" 45 1.77" AF26 ... AF38 3-pole Contactors AC / DC Operated - with Screw Terminals Catalogue Page 1SBC 101 091 S0201 Dimensions mm, inches 77 3.03" ø 4.2 0.17" 70 2.76" 10 0.39" 5 0.20" 10 0.39" 2x M4 8-32 UNC 5 0.20" 5.5 0.22" 35 1.38" 2x M4 8-32 UNC 70 2.76" 5.5 0.22" ø 4.2 0.17" 60 2.36" 35 mm EN/IEC 60715 6 0.24" 35 mm EN/IEC 60715 80 3.15" 6 0.24" 80 3.15" 35 1.38" 5.5 0.22" 5.5 0.22" 60 2.36" 71 2.80" 45 1.77" 80 3.15" 5 0.20" 86 3.39" 45 1.77" 5 0.20" AF26, AF30, AF38 AF26, AF30, AF38 86 3.39" 119.5 4.70" 45 1.77" 80 3.15" 10 0.39" 12 0.47" 80 3.15" 45 1.77" 80 3.15" 5.5 0.22" 35 mm EN/IEC 60715 6 0.24" 5.5 0.22" 43 1.69" 80 3.15" 35 mm EN/IEC 60715 6 0.24" 5.5 0.22" 5.5 0.22" 10 0.39" AF26, AF30, AF38 + CA4, CC4 1-pole auxiliary contact block AF26, AF30, AF38 + CAL4-11 2-pole auxiliary contact block 111.5 4.39" 119.5 4.70" 10 0.39" 45 1.77" AF26, AF30, AF38 + CA4 4-pole auxiliary contact block 35 mm EN/IEC 60715 80 3.15" 60 2.36" 60 2.36" 5.5 0.22" 43 1.69" 5.5 0.22" ø 4.2 0.17" AF26, AF30, AF38 + VEM4 mechanical and electrical interlock set 80 3.15" 2 x M4 8-32 UNC 4.2 0.17" 5ø 0.20" 2x M4 8-32 UNC 70 2.76" 10 0.39" 5.5 0.22" 35 mm EN/IEC 60715 35 mm EN/IEC 60715 91.5 3.60" 111.5 4.39" 80 10 3.15" 0.39" 5 0.20" 80 3.15" 70 2.76" 111.5 4.39" 90 3.54" 5.5 0.22" 91.5 3.60" 5.5 0.22" AF26, AF30, AF38 + CAT4 2-pole auxiliary contact and coil terminal block 43 1.69" 90 3.54" 10 0.39" 5.5 0.22" 80 3.15" 43 1.69" 80 3.15" 35 mm EN/IEC 60715 6 0.24" 5.5 0.22" 5.5 0.22" 80 3.15" 43 1.69" 80 3.15" 5 0.20" 45 1.77" 5 0.20" AF26, AF30, AF38 + VEM4 mechanical and electrical interlock set Note: contactor lateral distance to grounded component 2 mm 0.08" min. ABB | 21
AF26-22-00-12 价格&库存

很抱歉,暂时无法提供与“AF26-22-00-12”相匹配的价格&库存,您可以联系我们找货

免费人工找货