AF09 ... AF38 3-pole Contactors
up to 18.5 kW / 20 hp
Overview ...................................................................................................................................... 2
Ordering Details
– AF09 ... AF38 3-pole Contactors................................................................................................ 4
– AF..Z Additional Coils................................................................................................................... 5
Technical Data ............................................................................................................................. 6
Main Accessory Fitting Details.................................................................................................. 11
Accessory Ordering Details and Technical Data....................................................................... 12
Terminal Marking and Positioning............................................................................................. 18
1SBC 101 134 S0201
Dimensions................................................................................................................................. 20
ABB | 1
AF09 ... AF16
3-pole contactors
AF26 ... AF38
3-pole contactors
for Contactors
CAT4-11
2-pole auxiliary contact
and A1/A2 coil terminal block
BX4-CA
Protective cover
VM4
BX4-CA
Protective cover
CA4
4-pole auxiliary
contact block
A2
CA4, CC4
1-pole auxiliary
contact block
CAL4-11
2-pole auxiliary
contact block
Top or bottom
mounted
coil terminal block
BX4
Protective cover
VM4
BB4
Fixing clips
VE4
VEM4 mechanical and electrical interlock set including:
VM4 mechanical interlock unit including 2 fixing clips (BB4)
VE4 electrical interlock block with A2-A2 connection
for Starting Solutions
Direct-On-Line Starter
Reversing Starter
Star-Delta Starter
VEM4
mechanical &
electrical
interlock set
BER..-4 Connection set
including:
- Phase-to-phase connection
- Parallel connection
TF42 Thermal overload relay
EF.. Electronic overload relay
2 | ABB
A2
TF42 Thermal overload relay
EF.. Electronic overload relay
VEM4
mechanical &
electrical
interlock set
BEY..-4 Connection set
including:
- Phase-to-phase connection
- Parallel connection
- Star connection
TF42 Thermal overload relay
EF.. Electronic overload relay
1SBC 101 090 S0201
Main Accessories
Fixing clips
3-pole Contactors
AC / DC control voltage
AF09
AF12
AF16
AF26
AF09-30-10 AF12-30-10 AF16-30-10
AF30
AF38
AF26-30-00 AF30-30-00 AF38-30-00
AF09-30-01 AF12-30-01 AF16-30-01
Switching of 3-phase Cage Motors
Rated power
33
M
3
IEC
UL/CSA
AC-3
Rated
operational
current
400 V
θ ≤ 60 °C
400 V
θ ≤ 60 °C
415 V
θ ≤ 60 °C
690 V
480 V
Motor rating
Nema size
4 kW
9A
9A
7A
5 hp
00
5.5 kW
12 A
12 A
9A
7.5 hp
0
7.5 kW
18 A
18 A
10.5 A
10 hp
-
11 kW
26 A
26 A
17 A
15 hp
1
15 kW
32 A
32 A
21 A
20 hp
-
18.5 kW
38 A
38 A
24 A
20 hp
-
Protection of 3-phase motors
TF42...
setting range in A
Thermal overload relays
EF19...
Electronic overload relays
0.10 ... 0.32
EF45...
setting range in A
0.30 ... 1.0
0.80 ... 2.7
setting range in A
1.90 ... 6.3 5.7 ... 18.9
9.0 ... 30
15 ... 45
Switching of Resistive Circuits
33
IEC
AC-1
Rated
operational
current
θ ≤ 40 °C
690 V
θ ≤ 60 °C
690 V
θ ≤ 70 °C
690 V
With conductor cross-sectional area
R
R
UL/CSA
General use rating
With conductor cross-sectional area
600 V AC
25 A
25 A
22 A
4 mm2
25 A
AWG 10
28 A
28 A
24 A
6 mm2
28 A
AWG 10
30 A
30 A
26 A
6 mm2
30 A
AWG 10
45 A
40 A
32 A
10 mm2
45 A
AWG 8
50 A
42 A
37 A
10 mm2
50 A
AWG 8
50 A
42 A
37 A
10 mm2
50 A
AWG 8
Main Accessories
1-pole CA4-10 or CA4-01, CC4-10 or CC4-01
Auxiliary
contact
blocks
4-pole CA4
Front mounting
2-pole CAT4-11 (with coil front connection)
2-pole CAL4-11
Side mounting
Mechanical / electrical
VEM4
including VM4 mechanical interlock unit and VE4 electrical interlock block with A2-A2 connection
Interlocks
VM4
Mechanical
including 2 fixing clips
Reversing Starters
BER16-4
BER38-4
Star-Delta Starters
BEY16-4
BEY38-4
1SBC 101 090 S0201
Connection
sets
ABB | 3
AF09 ... AF38 3-pole Contactors
AC / DC Operated - with Screw Terminals
Catalogue Page 1SBC 101 060 S0201
4 to 18.5 kW
5 to 20 hp
Application
cULus
CE
AF09 ... AF38 contactors are used for controlling power circuits up to 690 V AC and 220 V DC.
They are mainly used for controlling 3-phase motors, non-inductive or slightly inductive loads.
Description
–– AF09 ... AF38 contactors include an electronic coil interface accepting a wide control voltage Uc min. ... Uc max.
Only four coils cover control voltages between 24...500 V 50/60 Hz or 20...500 V DC
–– AF contactors can manage large control voltage variations. One coil (e.g. 100...250 V 50/60 Hz - DC) can be
used for different control voltages used worldwide without any coil change
–– AF..Z contactors equipped with a Z coil type allow direct control by 24 V DC 500 mA PLC-output and obtain a
reduced holding coil consumption.
AF..Z contactors withstand short dips and voltage interruptions (SEMI F47-0706 compliance)
–– AF contactors have built-in surge protection and do not require additional surge suppressors
–– The built-in N.C. auxiliary contact is a mirror contact in compliance with annex F of IEC 60947-4-1.
AF09-30-10
Ordering Details
IEC
UL/CSA
Rated
power
400 V
AC-3
kW
4
3-phase Uc min. ... Uc max.
motor
rating
480 V
hp
V 50/60 Hz V DC
5
24...60
20...60
24...60
20...60
48...130
48...130
48...130
48...130
100...250
100...250
100...250
100...250
250...500
250...500
250...500
250...500
7.5
24...60
20...60
24...60
20...60
48...130
48...130
48...130
48...130
100...250
100...250
100...250
100...250
250...500
250...500
250...500
250...500
10
24...60
20...60
24...60
20...60
48...130
48...130
48...130
48...130
100...250
100...250
100...250
100...250
250...500
250...500
250...500
250...500
15
24...60
20...60
48...130
48...130
100...250
100...250
250...500
250...500
20
24...60
20...60
48...130
48...130
100...250
100...250
250...500
250...500
20
24...60
20...60
48...130
48...130
100...250
100...250
250...500
250...500
5.5
AF26-30-00
7.5
11
15
18.5
4 | ABB
Control voltage
Auxiliary Type
contacts
fitted
Order code
Weight
Pack(ing)
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
0
0
0
0
0
0
0
0
0
0
0
AF09Z-30-10-21
AF09Z-30-01-21
AF09-30-10-12
AF09-30-01-12
AF09-30-10-13
AF09-30-01-13
AF09-30-10-14
AF09-30-01-14
AF12Z-30-10-21
AF12Z-30-01-21
AF12-30-10-12
AF12-30-01-12
AF12-30-10-13
AF12-30-01-13
AF12-30-10-14
AF12-30-01-14
AF16Z-30-10-21
AF16Z-30-01-21
AF16-30-10-12
AF16-30-01-12
AF16-30-10-13
AF16-30-01-13
AF16-30-10-14
AF16-30-01-14
AF26Z-30-00-21
AF26-30-00-12
AF26-30-00-13
AF26-30-00-14
AF30Z-30-00-21
AF30-30-00-12
AF30-30-00-13
AF30-30-00-14
AF38Z-30-00-21
AF38-30-00-12
AF38-30-00-13
AF38-30-00-14
1SBL 136 001 R2110
1SBL 136 001 R2101
1SBL 137 001 R1210
1SBL 137 001 R1201
1SBL 137 001 R1310
1SBL 137 001 R1301
1SBL 137 001 R1410
1SBL 137 001 R1401
1SBL 156 001 R2110
1SBL 156 001 R2101
1SBL 157 001 R1210
1SBL 157 001 R1201
1SBL 157 001 R1310
1SBL 157 001 R1301
1SBL 157 001 R1410
1SBL 157 001 R1401
1SBL 176 001 R2110
1SBL 176 001 R2101
1SBL 177 001 R1210
1SBL 177 001 R1201
1SBL 177 001 R1310
1SBL 177 001 R1301
1SBL 177 001 R1410
1SBL 177 001 R1401
1SBL 236 001 R2100
1SBL 237 001 R1200
1SBL 237 001 R1300
1SBL 237 001 R1400
1SBL 276 001 R2100
1SBL 277 001 R1200
1SBL 277 001 R1300
1SBL 277 001 R1400
1SBL 296 001 R2100
1SBL 297 001 R1200
1SBL 297 001 R1300
1SBL 297 001 R1400
1 piece
kg
0.310
0.310
0.270
0.270
0.270
0.270
0.310
0.310
0.310
0.310
0.270
0.270
0.270
0.270
0.310
0.310
0.310
0.310
0.270
0.270
0.270
0.270
0.310
0.310
0.350
0.310
0.310
0.350
0.350
0.310
0.310
0.350
0.350
0.310
0.310
0.350
AF09 ... AF38 3-pole Contactors - AF..Z Additional Coils
AC / DC Operated - with Screw Terminals
Catalogue Page 1SBC 101 072 S0201
4 to 18.5 kW
5 to 20 hp
Application
cULus
CE
AF09Z ... AF38Z contactors are used for controlling power circuits up to 690 V AC and 220 V DC.
They are mainly used for controlling 3-phase motors, non-inductive or slightly inductive loads.
Description
– AF09Z ... AF38Z contactors include an electronic coil interface accepting a wide control voltage Uc min. ... Uc max
and managing large control voltage variations.
– AF..Z contactors cover control voltages comprised between 24...250 V 50/60 Hz or 12...250 V DC
– AF..Z contactors allow direct control by PLC-output ≥ 24 V DC 500 mA and obtain a reduced holding coil consumption.
AF..Z contactors withstand short dips and voltage interruptions (SEMI F47-0706 compliance)
– AF..Z contactors have built-in surge protection and do not require additional surge suppressors
– The built-in N.C. auxiliary contact is a mirror contact in compliance with annex F of IEC 60947-4-1.
Ordering Details
AF09Z-30-10
IEC
UL/CSA
Control voltage
Rated
power
400 V
AC-3
kW
4
3-phase
motor
rating
480 V
hp
5
Uc min. ... Uc max.
5.5
7.5
7.5
10
11
15
15
20
18.5
20
AF26Z-30-00
Auxiliary Type
contacts
fitted
Order code
Weight
Pack(ing)
V 50/60 Hz
24...60
24...60
48...130
48...130
100...250
100...250
24...60
24...60
48...130
48...130
100...250
100...250
24...60
24...60
48...130
48...130
100...250
100...250
24...60
48...130
100...250
24...60
48...130
100...250
24...60
48...130
100...250
V DC
12...20
12...20
20...60
20...60
48...130
48...130
100...250
100...250
12...20
12...20
20...60
20...60
48...130
48...130
100...250
100...250
12...20
12...20
20...60
20...60
48...130
48...130
100...250
100...250
12...20
20...60
48...130
100...250
12...20
20...60
48...130
100...250
12...20
20...60
48...130
100...250
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
0
0
0
0
0
0
0
0
0
0
0
AF09Z-30-10-20
AF09Z-30-01-20
AF09Z-30-10-21
AF09Z-30-01-21
AF09Z-30-10-22
AF09Z-30-01-22
AF09Z-30-10-23
AF09Z-30-01-23
AF12Z-30-10-20
AF12Z-30-01-20
AF12Z-30-10-21
AF12Z-30-01-21
AF12Z-30-10-22
AF12Z-30-01-22
AF12Z-30-10-23
AF12Z-30-01-23
AF16Z-30-10-20
AF16Z-30-01-20
AF16Z-30-10-21
AF16Z-30-01-21
AF16Z-30-10-22
AF16Z-30-01-22
AF16Z-30-10-23
AF16Z-30-01-23
AF26Z-30-00-20
AF26Z-30-00-21
AF26Z-30-00-22
AF26Z-30-00-23
AF30Z-30-00-20
AF30Z-30-00-21
AF30Z-30-00-22
AF30Z-30-00-23
AF38Z-30-00-20
AF38Z-30-00-21
AF38Z-30-00-22
AF38Z-30-00-23
1SBL 136 001 R2010
1SBL 136 001 R2001
1SBL 136 001 R2110
1SBL 136 001 R2101
1SBL 136 001 R2210
1SBL 136 001 R2201
1SBL 136 001 R2310
1SBL 136 001 R2301
1SBL 156 001 R2010
1SBL 156 001 R2001
1SBL 156 001 R2110
1SBL 156 001 R2101
1SBL 156 001 R2210
1SBL 156 001 R2201
1SBL 156 001 R2310
1SBL 156 001 R2301
1SBL 176 001 R2010
1SBL 176 001 R2001
1SBL 176 001 R2110
1SBL 176 001 R2101
1SBL 176 001 R2210
1SBL 176 001 R2201
1SBL 176 001 R2310
1SBL 176 001 R2301
1SBL 236 001 R2000
1SBL 236 001 R2100
1SBL 236 001 R2200
1SBL 236 001 R2300
1SBL 276 001 R2000
1SBL 276 001 R2100
1SBL 276 001 R2200
1SBL 276 001 R2300
1SBL 296 001 R2000
1SBL 296 001 R2100
1SBL 296 001 R2200
1SBL 296 001 R2300
1 piece
kg
0.310
0.310
0.310
0.310
0.310
0.310
0.310
0.310
0.310
0.310
0.310
0.310
0.310
0.310
0.310
0.310
0.310
0.310
0.310
0.310
0.310
0.310
0.310
0.310
0.350
0.350
0.350
0.350
0.350
0.350
0.350
0.350
0.350
0.350
0.350
0.350
Note: Only AF..Z contactors with DC control voltage 12...20 V DC need to respect the connection polarities indicated close to the coil terminals: A1+
for the positive pole and A2- for the negative pole
ABB | 5
AF09 ... AF38 3-pole Contactors
Technical Data
Catalogue Page 1SBC 101 108 S0201
Main Pole - Utilization Characteristics according to IEC
Contactor types
AF09
Standards
Rated operational voltage Ue max.
Rated frequency limits
Conventional free-air thermal current Ith
IEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1
690 V
25 ... 400 Hz
acc. to IEC 60947-4-1, open contactors, θ ≤ 40 °C
35 A
6 mm²
35 A
6 mm²
35 A
6 mm²
25 A
25 A
22 A
4 mm²
28 A
28 A
24 A
6 mm²
30 A
30 A
26 A
6 mm²
with conductor cross-sectional area
AC-1 Utilization category
for air temperature close to contactor
Ie / AC-1 rated operational current
Ue max. ≤ 690 V, 50/60 Hz
θ ≤ 40 °C
θ ≤ 60 °C
θ ≤ 70 °C
with conductor cross-sectional area
AC-3 Utilization category
for air temperature close to contactor θ ≤ 60 °C
AF12
AF16
AF26
AF30
AF38
50 A
10 mm²
50 A
10 mm²
50 A
10 mm²
45 A
40 A
32 A
10 mm²
50 A
42 A
37 A
10 mm²
50 A
42 A
37 A
10 mm²
9A
12 A
18 A
9A
12 A
18 A
9A
12 A
18 A
9A
12 A
18 A
9.5 A
12.5 A
15 A
7A
9A
10.5 A
2.2 kW
3 kW
4 kW
4 kW
5.5 kW
7.5 kW
4 kW
5.5 kW
9 kW
4 kW
5.5 kW
9 kW
5.5 kW
7.5 kW
9 kW
5.5 kW
7.5 kW
9 kW
10 x Ie AC-3 acc. to IEC 60947-4-1
8 x Ie AC-3 acc. to IEC 60947-4-1
26 A
26 A
26 A
26 A
23 A
17 A
6.5 kW
11 kW
11 kW
15 kW
15 kW
15 kW
33 A
32 A
32 A
32 A
28 A
21 A
9 kW
15 kW
15 kW
18.5 kW
18.5 kW
18.5 kW
40 A
38 A
38 A
38 A
33 A
24 A
11 kW
18.5 kW
18.5 kW
22 kW
22 kW
22 kW
12 A
5.5 kW
16 A
7.5 kW
22 A
11 kW
30 A
15 kW
40 A
20 kW
50 A
25 kW
25 A
300 A
150 A
80 A
60 A
35 A
250 A
106 A
0.8 W
0.1 W
600 cycles/h
1200 cycles/h
300 cycles/h
32 A
300 A
150 A
80 A
60 A
35 A
250 A
106 A
1W
0.2 W
32 A
300 A
150 A
80 A
60 A
35 A
250 A
106 A
1.2 W
0.35 W
50 A
700 A
350 A
225 A
150 A
50 A
500 A
200 A
1.8 W
0.6 W
63 A
700 A
350 A
225 A
150 A
50 A
500 A
200 A
2.4 W
0.9 W
63 A
700 A
350 A
225 A
150 A
50 A
500 A
200 A
2.4 W
1.3 W
(for 1500 r.p.m., 50 Hz or 1800 r.p.m., 60 Hz, 3-phase motors)
Ie / AC-3 max. rated operational current
3-phase motors
M
3
AC-3 rated operational power
M
3
1500 r.p.m. 50 Hz
1800 r.p.m. 60 Hz
3-phase motors
220-230-240 V
380-400 V
415 V
440 V
500 V
690 V
220-230-240 V
380-400 V
415 V
440 V
500 V
690 V
Rated making capacity AC-3
Rated breaking capacity AC-3
AC-8a Utilization category
(without thermal overload relay - Ue 400 V - θ ≤ 40 °C)
Ie / AC-8a rated operational current
AC-8a rated operational power
Short-circuit protection for contactors
without thermal O/L relay - Motor protection excluded
Ue ≤ 500 V AC - gG type fuse
Rated short-time withstand current Icw
at 40 °C ambient temperature, in free air from a cold state
Maximum breaking capacity
cos φ = 0.45
Heat dissipation per pole
Max. electrical switching frequency
6 | ABB
1s
10 s
30 s
1 min
15 min
at 440 V
at 690 V
Ie / AC-1
Ie / AC-3
AC-1
AC-3
AC-2, AC-4
150 cycles/h
AF09 ... AF38 3-pole Contactors
Technical Data
Catalogue Page 1SBC 101 108 S0201
Built-in Auxiliary Contacts according to IEC
AF09
Contactor types
Rated operational voltage Ue max.
Conventional free air thermal current Ith - θ ≤ 40 °C
Rated frequency limits
Rated operational current Ie / AC-15
acc. to IEC 60947-5-1
24-127 V 50/60 Hz
220-240 V 50/60 Hz
400-440 V 50/60 Hz
500 V 50/60 Hz
690 V 50/60 Hz
Making capacity AC-15
Breaking capacity AC-15
Rated operational current Ie / DC-13
acc. to IEC 60947-5-1
Short-circuit protection gG type fuse
Rated short-time withstand current Icw
24 V DC
48 V DC
72 V DC
110 V DC
125 V DC
220 V DC
250 V DC
400 V DC
500 V DC
600 V DC
for 1.0 s
for 0.1 s
Minimum switching capacity
with failure rate acc. to IEC 60947-5-4
Non-overlapping time between N.O. and N.C. contacts
Heat dissipation per pole at 6 A
Max. electrical switching frequency
AF12
AF16
AF26
AF30
AF38
690 V
16 A
25 ... 400 Hz
AC-15
DC-13
6A
4A
3A
2A
2A
10 x Ie AC-15 acc. to IEC 60947-5-1
10 x Ie AC-15 acc. to IEC 60947-5-1
6 A / 144 W
2.8 A / 134 W
1 A / 72 W
0.55 A / 60 W
0.55 A / 69 W
0.27 A / 60 W
0.27 A / 68 W
0.15 A / 60 W
0.13 A / 65 W
0.1 A / 60 W
10 A
100 A
140 A
12 V / 3 mA
10-7
≥ 2 ms
0.1 W
1200 cycles/h
900 cycles/h
ABB | 7
AF09 ... AF38 3-pole Contactors
Technical Data
Catalogue Page 1SBC 101 108 S0201
Main Pole - Utilization Characteristics according to UL / NEMA / CSA
Contactor types
AF09
Standards
Rated operational voltage Ue max.
NEMA size
NEMA continuous amp rating
NEMA maximum H.P. ratings 1-phase, 60 Hz
UL 508, CSA C22.2 N°14
600 V
00
0
9A
18 A
1/3 hp
1 hp
1 hp
2 hp
1-1/2 hp
3 hp
1-1/2 hp
3 hp
2 hp
5 hp
2 hp
5 hp
NEMA maximum H.P. ratings 3-phase, 60 Hz
UL General use rating
600 V AC
With conductor cross-sectional area
80 V DC - 1-pole
With conductor cross-sectional area
UL maximum 1-phase motor rating
Amp-rating
Motor power
UL maximum 3-phase motor rating
Amp-rating
Motor power
(for 1500 r.p.m., 50 Hz or 1800 r.p.m., 60 Hz 3-phase motors)
thermal current
115 V AC
230 V AC
200 V AC
230 V AC
460 V AC
575 V AC
120 V AC
240 V AC
120 V AC
240 V AC
200-208 V AC
220-240 V AC
440-480 V AC
550-600 V AC
200-208 V AC
220-240 V AC
440-480 V AC
550-600 V AC
AF12
AF16
AF26
AF30
AF38
-
1
27 A
2 hp
3 hp
7-1/2 hp
7-1/2 hp
10 hp
10 hp
-
-
25 A
AWG 10
25 A
AWG 10
28 A
AWG 10
28 A
AWG 10
30 A
AWG 10
30 A
AWG 10
45 A
AWG 8
45 A
AWG 8
50 A
AWG 8
50 A
AWG 8
50 A
AWG 8
50 A
AWG 8
13.8 A
10 A
3/4 hp
1-1/2 hp
16 A
12 A
1 hp
2 hp
20 A
17 A
1-1/2 hp
3 hp
24 A
17 A
2 hp
3 hp
24 A
28 A
2 hp
5 hp
24 A
28 A
2 hp
5 hp
7.8 A
6.8 A
7.6 A
9A
2 hp
2 hp
5 hp
7.5 hp
11 A
9.6 A
11 A
11 A
3 hp
3 hp
7.5 hp
10 hp
17.5 A
15.2 A
14 A
17 A
5 hp
5 hp
10 hp
15 hp
25.3 A
22 A
21 A
22 A
7.5 hp
7.5 hp
15 hp
20 hp
32.2 A
28 A
27 A
32.2 A
28 A
27 A
60 A
NTD
60 A
60 A
AF16
(1)
(1)
10 hp
10 hp
20 hp
10 hp
10 hp
20 hp
(1)
(1)
150 A
150 A
150 A
AF26
AF30
AF38
Short-circuit protection
for contactors without thermal O/L relay - Motor protection excluded
Fuse rating
Fuse type, 600 V
Max. electrical switching frequency
for general use
for motor use
Mechanical durability
Number of operating cycles
Max. switching frequency
600 cycles/h
1200 cycles/h
10 millions operating cycles
3600 cycles/h
(1) On request
Built-in Auxiliary Contacts according to UL / CSA
Contactor types
AF09
Max. rated operational voltage Ue max.
Pilot duty
AC thermal rated current
AC maximum volt-ampere making
AC maximum volt-ampere breaking
DC thermal rated current
DC maximum volt-ampere making-breaking
600 V AC, 600 V DC
A600, Q600
10 A
7200 VA
720 VA
2.5 A
69 VA
8 | ABB
AF12
AF09 ... AF38 3-pole Contactors
Technical Data
Catalogue Page 1SBC 101 108 S0201
General Technical Data
AF09
Contactor types
Rated insulation voltage Ui
AF12
AF16
AF26
AF30
AF38
690 V
600 V
6 kV
Devices complying with IEC 60947-1 / EN 60947-1 - Environment A
acc. to IEC 60947-4-1
acc. to UL / CSA
Rated impulse withstand voltage Uimp.
Electromagnetic compatibility
Ambient air temperature close to contactor
Operation
fitted with thermal overload relay
without thermal overload relay
Storage
Climatic withstand
Operating altitude
Mechanical durability
Number of operating cycles
Max. switching frequency
Shock withstand
-40 ... +70 °C
-60 ... +80 °C
Category B according to IEC 60947-1 Annex Q
≤ 3000 m
10 millions operating cycles
3600 cycles/h
acc. IEC 60068-2-27 and EN 60068-2-27
Mounting position 1
Closed or open
position
C1
A
A
B1
B2
C2
Shock direction
A
B1
B2
C1
C2
Vibration withstand
acc. to IEC 60068-2-6
1/2 sinusoidal shock for 11 ms: no change in contact position
30 g
25 g Closed position / 5 g Open position
15 g
25 g
25 g
5 ... 300 Hz
4 g Closed position / 2 g Open position
Magnet System Characteristics
AF09
Contactor types
Coil operating limits
AF12
AF16
AF26
AF30
AF38
AC supply
at θ ≤ 60 °C 0.85 x Uc min ... 1.1 x Uc max
at θ ≤ 70 °C 0.85 x Uc min ... Uc max
DC supply
at θ ≤ 60 °C 0.85 x Uc min ... 1.1 x Uc max
at θ ≤ 70 °C (AF) 0.85 x Uc min ... Uc max - (AF..Z) 0.85 x Uc min ... 1.1 x Uc max
24 ... 500 V AC
(AF) 50 VA - (AF..Z) 16 VA
(AF) 2.2 VA / 2 W - (AF..Z) 1.7 VA / 1.5 W
12 ... 500 V DC
(AF) 50 W - (AF..Z) 12 ... 16 W
(AF) 2 W - (AF..Z) 1.7 W
(AF..Z) ≥ 500 mA 24 V DC
≤ 60 % Uc min
(AF..Z) conditions of use on request
(AF..Z) 22 ms average for Uc = 24 ... 250 V 50/60Hz
acc. to IEC 60947-4-1
AC control voltage
50/60 Hz
Rated control circuit voltage Uc
Average pull-in value
Coil consumption
DC control voltage
Rated control circuit voltage Uc
Average pull-in value
Coil consumption
Average holding value
Average holding value
PLC-Output control
Drop-out voltage in % of Uc min.
Voltage sag immunity according to SEMI F47-0706
Dips withstand (level 0% according to IEC 61000-4-11)
-20 °C ≤ θ ≤ +60 °C
Operating time
N.O. contact closing 40 ... 95 ms
between coil energization and:
N.C. contact opening 38 ... 90 ms
N.O. contact opening 11 ... 95 ms
between coil de-energization and:
N.C. contact closing 13 ... 98 ms
Mounting Characteristics
Contactor types
AF09
Mounting positions
AF12
Pos. 2
+30°
AF16
AF26
AF30
AF38
-30°
Pos. 4
Pos. 3
Pos. 1
Mounting distances
Fixing
on rail according to IEC 60715, EN 60715
by screws (not supplied)
Pos. 1 ± 30°
Pos. 5
Max. N.C. built-in and add-on N.C. auxiliary contacts: see accessory fitting details for a
3-pole contactor AF09 ... AF38
The contactors can be assembled side by side.
35 x 7.5 mm or 35 x 15 mm
2 x M4 screws placed diagonally
ABB | 9
AF09 ... AF38 3-pole Contactors
Technical Data
Catalogue Page 1SBC 101 108 S0201
Connecting Characteristics
AF09
Contactor types
AF12
AF16
AF26
AF30
Main terminals
Screw terminals with cable clamp
Connecting capacity (min. ... max.)
Main conductors (poles)
Rigid
solid (≤ 4 mm²)
stranded (≥ 6 mm²)
Flexible with non insulated ferrule
Flexible with insulated ferrule
L
6
Bars or lugs
Capacity according to UL/CSA
Stripping length
Auxiliary conductors
(built-in auxiliary terminals + coil terminals)
Rigid solid
Flexible with non insulated ferrule
Flexible with insulated ferrule
L
6
Bars or lugs
Capacity according to UL/CSA
Stripping length
Degree of protection
1x
2x
1x
2x
1x
2x
L<
1 or 2 x
1 ... 6 mm²
1 ... 6 mm²
0.75 ... 6 mm²
0.75 ... 6 mm²
0.75 ... 4 mm²
0.75 ... 2.5 mm²
9.6 mm
2.5 ... 10 mm²
2.5 ... 10 mm²
1.5 ... 10 mm²
1.5 ... 10 mm²
1.5 ... 10 mm²
1.5 ... 4 mm²
12.5 mm
AWG 16 ... 10
10 mm
AWG 14 ... 8
14 mm
1x
2x
1 ... 2.5 mm²
1 ... 2.5 mm²
1x
2x
1x
2x
L<
0.75 ... 2.5 mm²
0.75 ... 2.5 mm²
0.75 ... 2.5 mm²
0.75 ... 1.5 mm²
8 mm
1 or 2 x
AWG 18 ... 14
10 mm
acc. to IEC 60947-1 / EN 60947-1 and IEC 60529 / EN 60529
Main terminals
Coil terminals
Built-in auxiliary terminals
Screw terminals
Main terminals
Coil terminals
Built-in auxiliary terminals
Screwdriver type
Tightening torque
Main pole terminals
Coil terminals
Built-in auxiliary terminals
10 | ABB
IP20
IP20
IP20
(delivered in open position, screws of unused terminals must be tightened)
M3.5
M4
M3.5
M3.5
Flat Ø5.5 / Pozidriv 2
1.5 Nm / 13 lb.in
1.2 Nm / 11 lb.in
1.2 Nm / 11 lb.in
2.5 Nm / 22 lb.in
AF38
AF09 ... AF38 3-pole Contactors
Main Accessories
Catalogue Page 1SBC 101 066 S0201
Accessory fitting details for a 3-pole contactor AF09 ... AF38
Many configurations of accessories are possible depending on whether these are front-mounted or side-mounted.
Contactor
types
Main
poles
Built-in
auxiliary
contacts
Front-mounted accessories
Side-mounted accessories
Auxiliary contact blocks
Electrical and mechanical
interlock set
Auxiliary contact blocks
(between 2 contactors)
1-pole CA4
Left side
1-pole CC4
2-pole CAT4-11
4-pole CA4
Right side
2-pole CAL4-11
VEM4
Max. N.C. built-in and add-on N.C. auxiliary contacts: 4 N.C. max. on positions 1, 2, 3, 4 and 3 N.C. max. on positions 1 ±30°, 5
3 0
AF09 ... AF16
0 1
AF09 ... AF16
3 0
1 0
AF26 ... AF38
3 0
0 0
4 max.
or 1
or 1
–
+ 1
–
2 max.
–
–
–
+ 1
+ 1
or 1
3 max.
–
–
+ 1
+ 1
4 max.
or 1
or 1
–
+ 1
–
2 max.
or 1
–
–
+ 1
+ 1
3 max.
–
–
+ 1
+ 1
or 1
Mounting positions
Pos. 2
+30°
-30°
Pos. 4
Pos. 3
Pos. 1
Pos. 1 ± 30°
Pos. 5
Protection against overloads with thermal or electronic overload relays
The addition of an overload relay on the contactor does not prevent fitting of many other accessories as shown below.
Contactor types
Overload relays - direct mounting - no kit required
AF09 ... AF38
TF42 thermal overload relay
AF09 ... AF38
EF19 electronic overload relay
AF26 ... AF38
EF45 electronic overload relay
Contactors and main accessories (other accessories available)
VEM4 mechanical and electrical interlock set including:
– VM4 mechanical interlock unit including 2 fixing clips
– VE4 electrical interlock block with A2-A2 connection
AF contactor
(without top mounted
coil terminal block)
AF contactor
Fixing clips
A2
A2
AF contactor
2-pole CAT4-11
VM4
1-pole
CA4, CC4
4-pole CA4
2-pole CAL4-11
1-pole CA4, CC4
VE4
2-pole CAL4-11
1-pole
CA4, CC4
TF42
EF..
TF42
EF..
ABB | 11
Auxiliary Contact Blocks
Accessories for AF09 ... AF38 3-pole Contactors
Catalogue Page 1SBC 101 135 S0201
Application
The auxiliary contact blocks are used for the operation of auxiliary circuits and control circuits.
Description
CA4-10
Types of auxiliary contact blocks for standard industrial environments:
–– CA4 1 or 4-pole block, front-mounted, instantaneous with N.O., N.C. contacts
–– CC4 1-pole block, front-mounted, with N.O. leading contact or N.C. lagging contact
–– CAT4 2-pole block, front-mounted, instantaneous N.O. + N.C. contacts with A1 / A2 coil terminal connection
on front face
–– CAL4 2-pole block instantaneous N.O. + N.C. contacts clipped onto the right and/or left side of the contactors.
Select the type of 2 or 4-pole auxiliary contact blocks CAT4 or CA4-..E, CA 4-..M or CA 4-..U, according to the
contactor type for compliance with the standard requirements (see terminal and marking positioning).
The auxiliary contact blocks are equipped with screw type connecting terminals delivered open, protected against
accidental direct contact and bear the corresponding function marking.
Fitting Details - For each contactor refer to "Accessory Fitting Details" table.
CA4-22M
Ordering Details
For contactors
Auxiliary contacts
Type
Order code
Pack(ing) Weight
pieces
kg (1 pce)
Front-mounted instantaneous auxiliary contact blocks
AF09 ... AF38
AF09 ... AF16..-30-10
CAL4-11
AF26 ... AF38..-30-00
AF09 ... AF16..-30-01
CAT4-11E
1
1
0
0
2
3
1
0
2
3
4
0
2
3
4
0
0
1
1
2
1
3
4
2
1
0
4
2
1
0
-
-
CA4-10
CA4-10-T
CA4-01
CA4-01-T
CA4-22M
CA4-31M
CA4-13M
CA4-04M
CA4-22E
CA4-31E
CA4-40E
CA4-04E
CA4-22U
CA4-31U
CA4-40U
1SBN 010 110 R1010
1SBN 010 110 T1010
1SBN 010 110 R1001
1SBN 010 110 T1001
1SBN 010 140 R1122
1SBN 010 140 R1131
1SBN 010 140 R1113
1SBN 010 140 R1104
1SBN 010 140 R1022
1SBN 010 140 R1031
1SBN 010 140 R1040
1SBN 010 140 R1004
1SBN 010 140 R1322
1SBN 010 140 R1331
1SBN 010 140 R1340
1
10
1
10
1
1
1
1
1
1
1
1
1
1
1
0.014
0.014
0.014
0.014
0.055
0.055
0.055
0.055
0.055
0.055
0.055
0.055
0.055
0.055
0.055
Front-mounted auxiliary contact blocks with N.O. leading contact and N.C. lagging contact
AF09 ... AF38
- - -
1 0
0 1
CC4-10
CC4-01
1SBN 010 111 R1010
1SBN 010 111 R1001
1
1
0.014
0.014
1SBN 010 120 R1011
1SBN 010 120 T1011
1
10
0.040
0.040
1
1
1
0.040
0.040
0.040
Side-mounted instantaneous auxiliary contact blocks
AF09 ... AF38
1 1
1 1
- - -
CAL4-11
CAL4-11-T
Front-mounted instantaneous auxiliary contact and A1/A2 coil terminal blocks
AF09 ... AF16..-30-10
AF26 ... AF38..-30-00
AF09 ... AF16..-30-01
1 1
1 1
1 1
- - - -
CAT4-11M
CAT4-11E
CAT4-11U
Note: CAT4 not fittable on AF..Z contactors with DC control voltage 12...20 V DC.
12 | ABB
1SBN 010 151 R1111
1SBN 010 151 R1011
1SBN 010 151 R1311
Auxiliary Contact Blocks
Accessories for AF09 ... AF38 3-pole Contactors
Catalogue Page 1SBC 101 136 S0201
Technical Data
1-pole CA4, 1-pole CC4, 4-pole CA4, 2-pole CAT4, 2-pole CAL4
Types
Contact Utilization Characteristics according to IEC
Standards
Rated insulation voltage Ui acc. to IEC 60947-5-1
Rated impulse withstand voltage Uimp
Rated operational voltage Ue max.
Conventional thermal current Ith - θ ≤ 40 °C
Rated frequency limits
Rated operational current Ie / AC-15
acc. to IEC 60947-5-1
24-127 V 50/60 Hz
220-240 V 50/60 Hz
400-440 V 50/60 Hz
500 V 50/60 Hz
690 V 50/60 Hz
Making capacity acc. to IEC 60947-5-1
Breaking capacity acc. to IEC 60947-5-1
Rated operational current Ie / DC-13
acc. to IEC 60947-5-1
Short-circuit protection gG type fuse
Rated short-time withstand current Icw
θ = 40 °C
24 V DC
48 V DC
72 V DC
110 V DC
125 V DC
220 V DC
250 V DC
400 V DC
500 V DC
600 V DC
for 1.0 s
for 0.1 s
Minimum switching capacity
with failure rate acc. to IEC 60947-5-4
Heat dissipation per pole at 6 A
Mechanical durability
Number of operating cycles
Max. switching frequency
Max. electrical switching frequency
for AC-15
for DC-13
IEC 60947-5-1 and EN 60947-5-1
690 V
6 kV
24 ... 690 V
16 A
25 ... 400 Hz
6A
4A
3A
2A
2A
10 x Ie AC-15 acc. to IEC 60947-5-1
10 x Ie AC-15 acc. to IEC 60947-5-1
6 A / 144 W
2.8 A / 134 W
1 A / 72 W
0.55 A / 60 W
0.55 A / 69 W
0.27 A / 60 W
0.27 A / 68 W
0.15 A / 60 W
0.13 A / 65 W
0.1 A / 60 W
10 A
100 A
140 A
12 V / 3 mA
10-7
0.1 W
10 millions operating cycles
3600 cycles/h
1200 cycles/h
900 cycles/h
Contact Utilization Characteristics according to UL / CSA
UL 508, CSA C22.2 N°14
600 V
600 V AC, 600 V DC
A600, Q600
10 A
7200 VA
720 VA
2.5 A
69 VA
Standards
Rated insulation voltage Ui
Max. rated voltage
Pilot duty
AC thermal rated current
AC maximum volt-ampere making
AC maximum volt-ampere breaking
DC thermal rated current
DC maximum volt-ampere making-breaking
Connecting Characteristics
Screw terminals
All terminals
Connecting capacity (min. ... max.)
Rigid solid
Flexible with non insulated ferrule
Flexible with insulated ferrule
L
6
Bars or lugs
Capacity acc. to UL/CSA
Stripping length
Degree of protection
acc. to IEC 60947-1 / EN 60947-1 and IEC 60529 / EN 60529
Screwdriver type
Tightening torque
(delivered in open position, screws of unused terminals must be tightened)
M3.5
1x
2x
1x
2x
1x
2x
L<
1 or 2 x
1 ... 2.5 mm²
1 ... 2.5 mm²
0.75 ... 2.5 mm²
0.75 ... 2.5 mm²
0.75 ... 2.5 mm²
0.75 ... 1.5 mm²
8 mm
AWG 18 ... 14
10 mm
IP20
Flat Ø5.5 / Pozidriv 2
1.2 Nm / 11 lb.in
ABB | 13
Connexion Accessories for Starting Solutions
Accessories for AF09 ... AF38 3-pole Contactors
Catalogue Page 1SBC 101 137 S0201
Connecting links with manual motor starters
Description
The BEA..-4 connecting links are used to connect AF09 ... AF38 contactors with the MS116 or MS132 manual
motor starters.
The BEA..-4 insulated 3-pole connecting links ensure the electrical and mechanical connection between the contactor and the associated manual motor starter.
Ordering Details
For contactors
Type
Order code
Pack(ing) Weight
pieces
BEA16-4
kg (1 pce)
AF09 ... AF16 with MS116 and MS132
AF26 ... AF38 with MS132-12 ... MS132-32
BEA16-4
BEA38-4
1SBN 081 306 T1000
1SBN 082 306 T2000
10
10
0.025
0.030
Connection sets for reversing contactors
Description
A1
A2
1
3
5
1
3
5
2
4
6
2
4
6
A1
A2
BER16-4 and BER38-4 connection sets between the main poles of two 3-pole contactors mounted side by side.
The connection sets are made up of 1 upstream and 1 downstream connections: insulated, solid copper bars.
Ordering Details
For contactors
Type
Order code
Pack(ing) Weight
pieces
kg (1 pce)
AF09 ... AF16
AF26 ... AF38
BER16-4
BER38-4
1SBN 081 311 R1000
1SBN 082 311 R1000
1
1
0.045
0.100
Connection sets for Star-Delta starting
BER16-4
A1
A2
Description
1
3
5
2
4
6
A1
A2
1
3
5
2
4
6
A1
A2
1
3
5
2
4
6
BEY16-4 and BEY38-4 connection sets between the main poles of the Line, Delta and Star contactors of a StarDelta starter.
The connection sets are made up of:
— Line contactor / Delta contactor: upstream phase-to-phase connection
— Delta contactor / Star contactor: downstream connection in parallel
— Star contactor: Star point upstream.
Ordering Details
BEY16-4
14 | ABB
For Line, Delta and
Star contactors
Interlock unit
between Delta & Star
contactors
Type
AF09 ... AF16
AF26 ... AF38
With or without
VM4 or VEM4
BEY16-4
BEY38-4
Order code
Pack(ing) Weight
pieces
kg (1 pce)
1SBN 081 313 R2000
1SBN 082 713 R2000
1
1
0.050
0.110
Interlocks
Accessories for AF09 ... AF38 3-pole Contactors
Catalogue Page 1SBC 101 146 S0201
Mechanical interlock unit
Description
VM4 mechanical interlock unit for the interlocking of two AF contactors.
When mounted between two contactors without additional width, the VM4 mechanical interlock unit prevents one
of the contactors from closing as long as the other contactor is closed.
The mechanical interlock unit includes 2 fixing clips (BB4).
Ordering Details
For contactors
Type
Order code
Pack(ing) Weight
pieces
VM4
kg (1 pce)
AF09 ... AF38
VM4
1SBN 030 105 T1000
10
0.005
Mechanical and electrical interlock set
Description
VEM4 mechanical and electrical interlock set for the interlocking of two AF contactors.
VEM4 set includes a mechanical interlock unit VM4 with 2 fixing clips (BB4) and a VE4 electrical interlock block
with A2-A2 connection.
Fixing the electrical interlock block to the contactor front face connects the 2 built-in N.C. interlocking contacts
with the two coils. VE4 block must be used with A2-A2 connection to respect the electrical connection diagram.
Ordering Details
For contactors
VEM4
01 NC
Auxiliary Type
contacts
Order code
Pack(ing) Weight
pieces
1SBN 030 111 R1000
1
Order code
Pack(ing) Weight
01NC
kg (1 pce)
KM1
A2
KM2
VEM4
A2
AF09 .. AF16
AF26 .. AF38
1 1
VEM4
0.035
Note: VEM4 not fittable on AF..Z contactors with DC control voltage 12...20 V DC.
Fixing clips
Ordering Details
For contactors
Type
pieces
kg (1 pce)
BB4
AF09 ... AF38
BB4
1SBN 110 120 W1000
50
0.002
ABB | 15
Interlocks
Accessories for AF09 ... AF38 3-pole Contactors
Technical Data
VM4
Interlock types
Mechanical durability
Number of operating cycles
5 millions operating cycles
Max. switching frequency
1800 cycles/h
VEM4
Interlock types
Contact Utilization Characteristics according to IEC
Standards
IEC 60947-5-1 and EN 60947-5-1
Rated insulation voltage Ui acc. to IEC 60947-5-1
690 V
Rated impulse withstand voltage Uimp
6 kV
Rated control circuit voltage Uc
AC 50/60 Hz control voltage
DC control voltage
Conventional thermal current Ith - θ ≤ 40 °C
Mechanical and electrical durability
24 ... 500 V AC
20 ... 500 V DC
16 A
Number of operating cycles
5 millions operating cycles
Max. mechanical switching frequency
1800 cycles/h
Max. electrical switching frequency
1200 cycles/h
Contact Utilization Characteristics according to UL / CSA
Standards
UL 508, CSA C22.2 N°14
Max. rated voltage
500 V AC, 500 V DC
Connecting Characteristics
Screw terminals
All terminals
M3.5
Connecting capacity (min. ... max.)
Rigid Solid
Flexible with non insulated ferrule
Flexible with insulated ferrule
L
6
Bars or lugs
Capacity according to UL/CSA
1x
1 ... 2.5 mm²
2x
1 ... 2.5 mm²
1x
0.75 ... 2.5 mm²
2x
0.75 ... 2.5 mm²
1x
0.75 ... 2.5 mm²
2x
0.75 ... 1.5 mm²
L<
8 mm
1 or 2 x
AWG 18 ... 14
Stripping length
Degree of protection
10 mm
acc. to IEC 60947-1 / EN 60947-1 and IEC 60529 / EN 60529
IP20
Screwdriver type
Flat Ø5.5 / Pozidriv 2
Tightening torque
1.2 Nm / 11 lb.in
16 | ABB
Catalogue Page 1SBC 101 146 S0201
Other Accessories
Accessories for AF09 ... AF38 3-pole Contactors
Catalogue Page 1SBC 101 147 S0201
Additional coil terminal block
Description
Additional coil terminal block for a bottom access to the coil terminals of contactors or contactor relays.
Ordering Details
For contactors
Type
Order code
Pack(ing) Weight
pieces
kg (1 pce)
LDC4
AF09 ... AF38
LDC4
1SBN 070 156 T1000
10
0.010
Protective covers
Description
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Ordering Details
For contactors
Type
Order code
Pack(ing) Weight
pieces
kg (1 pce)
BX4
All 1-stack contactors
BX4
For 4-pole CA4 and 2-pole CAT4 auxiliary contact BX4-CA
blocks
1SBN 110 108 T1000
1SBN 110 109 W1000
10
50
0.006
0.001
BX4-CA
Function markers
Description
Box of 16 blank cards (16 markers by card) printable on HTP500 thermal transfer printer and AMS 500 marking
table to identify your contactors, overload relays or manual motor starters.
Marker dimensions: 7 x 20 mm (.276" x .787")
Ordering Details
For contactors
Type
Order code
Pack(ing) Weight
pieces
kg (1 pce)
BA4
Marker card
AMS 500 support plate for 8 BA4
HTP500 support plate
BA4
SPRC 1
HTP500-BA4
1SNA 235 156 R2700
1SNA 360 010 R1500
1SNA 235 712 R2400
16
1
1
0.011
0.220
0.290
ABB | 17
AF09 ... AF38 3-pole Contactors
Terminal Marking and Positioning
Catalogue Page 1SBC 101 113 S0201
Standard devices without addition of auxiliary contacts
A1 A2
A1 A2
A1 A2
1L1 3L2 5L3
13
1L1 3L2 5L3
NO
21
3L2
1L1
A1
1L1
3L2
5L3
13
NO
A1
1L1
3L2
5L3
A2
2T1
4T2
6T3
NO
14
A2
2T1
4T2
6T3
5L3
NC
AF09...AF16..-30-10
NO
2T1 4T2 6T3
AF26...AF38..-30-00
A1
1L1
3L2
5L3
21
NC
A2
2T1
4T2
6T3
NC
22
NC
14
2T1 4T2 6T3
A1 A2
2T1
22
A1 A2
AF09...AF16..-30-10
4T2
6T3
A1 A2
AF09...AF16..-30-01
AF26...AF38..-30-00
AF09...AF16..-30-01
Other possible contact combinations with auxiliary contacts added by the user
A1 A2
1L1 3L2 5L3
1L1 3L2 5L3
NO
21
A1 A2
A1 A2
13
13
1L1
NO
2-
=
NC
22
+
2-
NO
2T1 4T2 6T3
3L2
-1
13 21
NC
NO NC
-2
14 22
A1 A2
5L3
14
2T1
A1 A2
4T2
6T3
13
1L1 3L2 5L3
NO
1L1 3L2 5L3
NO
+
NC
NO
NC NC
NO
2T1 4T2 6T3
14
2T1 4T2 6T3
Combination 21 = AF09...AF16..-30-10 +
A1 A2
NO
NO
13X
21X
=
NC
NO
2T1 4T2 6T3
5L3
13
NO
21
NC
A2
2T1
4T2
6T3
NO
14
NC
22
+
NC
Combination 11
-2
4T2
6T3
A1 A2
13
1L1 3L2 5L3
NO
CAT4-11M
14
A1
1L1
3L2
5L3
13
NO
21
NC
33
NO
A2
2T1
4T2
6T3
NO
14
NC
22
NO
34
13
NO
=
21 31 43 53
+
NC
NC
NO
NO
22 32 44 54
Combination 21
A1
1L1
3L2
5L3
13
NO
21
NC
31
NC
43 53
NO NO
A2
2T1
4T2
6T3
NO
14
NC
22
NC
32
NO NO
44 54
NO
2T1 4T2 6T3
14
A1 A2
Combination 32 = AF09...AF16..-30-10 +
CA4-22M
Combination 32
A1 A2
13
NC
22X
14X
3L2
A1 A2
NO
A1 A2
13X
21X
NO
-1
-4
22 32 44 54
NO
14
1L1 3L2 5L3
+
21 31 43 53
22 34 A2
NO
NO
-3
NO
A1 21 33
22 34 A2
2T1 4T2 6T3
2-
1L1
Combination 11 = AF26...AF38..-30-00 + CA4-10 + CA4-01
13
=
NO
1-
2T1
A1 A2
NC
2-
=
A1 A2
Combination 11 = AF09...AF16..-30-10 + CA4-01
A1 21 33
1-
A1
5L3
NO
2T1 4T2 6T3
14
A1 A2
1L1 3L2 5L3
3L2
1L1
NC
NC
NO
22X
14X
14
NO
1L1 3L2 5L3
+
A1 A2
Combination 21
13
NO
2T1 4T2 6T3
CAL4-11 +
1L1
3L2
5L3
13 13X 21X
NO NO NC
A2
2T1
4T2
6T3
NO NO NC
14 14X 22X
14
A1 A2
=
A1
NO
AF09...AF16..-30-10
Combination 21
Note: Only AF..Z contactor with DC control voltage 12...20 V DC need to respect the connection polarities indicated close to the coil terminals: A1+ for the positive pole and A2- for the negative pole
18 | ABB
Add-on Auxiliary Contacts
Terminal Marking and Positioning
Catalogue Page 1SBC 101 113 S0201
1-pole auxiliary contacts
-1
-5
-3
NO
NC
-4
-2
CA4-01
-7
NO
NC
-8
-6
CA4-10
CC4-01
CC4-10
2-pole auxiliary contacts
31X
43X
CAL4-11
(Left side-mounted)
32X /
NO
44X /
21X
44X
22X /
43X /
NC
NC
21
CAL4-11
(Right side-mounted)
33
NC
13X
32X
14X /
31X /
22X
21X /
NO
14X
13X /
13
NO
22
NO
34
21
NC
14
CAT4-11M
CAT4-11E
-3
NO
22
-1
NC
-4
-2
CAT4-11U
4-pole auxiliary contacts
13
NO
14
23
NO
33
NO
24
43
NO
34
44
CA4-40E
13
NO
14
21
NC
22
13
14
31
41
NC
NC
NC
22
32
42
53
NO
54
CA4-13M
33
NO
34
43
NO
44
CA4-31E
NO
21
21
NC
22
33
NO
43
44
53
NO
54
CA4-31M
21
31
NC
NC
22
32
43
NO
44
CA4-22E
21
31
NC
NC
22
32
3
NO
4
3
NO
4
4
3
NO
4
1
NC
2
3
NO
4
3
NO
4
CA4-31U
43
NO
44
53
NO
54
CA4-22M
3
NO
4
1
1
NC
NC
2
2
3
NO
4
CA4-22U
11
21
31
41
21
31
41
51
NC
NC
NC
NC
NC
NC
NC
NC
12
22
32
42
22
32
42
52
CA4-04E
4
3
NO
CA4-40U
NO
34
3
NO
CA4-04M
ABB | 19
AF09 ... AF16 3-pole Contactors
AC / DC Operated - with Screw Terminals
Catalogue Page 1SBC 101 091 S0201
Dimensions mm, inches
77 3.03"
10 0.39"
ø 4.2 0.17"
70 2.76"
2x
M4 8-32 UNC
10 0.39"
5 0.20"
5 0.20"
5.5 0.22"
35 1.38"
2x
M4 8-32 UNC
70 2.76"
5.5 0.22"
35 1.38"
ø 4.2 0.17"
60 2.36"
35 mm EN/IEC 60715
6 0.24"
35 mm EN/IEC 60715
80 3.15"
6 0.24"
80 3.15"
5.5 0.22"
60 2.36"
71 2.80"
5.5 0.22"
5 0.20"
77 3.03"
2.80"
45711.77"
45 1.77"
5 0.20"
AF09, AF12, AF16
AF09, AF12, AF16
110.5 4.35"
71 2.80"
45 1.77"
77 3.03"
10 0.39"
12 0.47"
71 2.80"
45 1.77"
80 3.15"
5.5 0.22"
35 mm EN/IEC 60715
6 0.24"
5.5 0.22"
43 1.69"
80 3.15"
35 mm EN/IEC 60715
6 0.24"
5.5 0.22"
5.5 0.22"
10 0.39"
AF09, AF12, AF16
+ CA4, CC4 1-pole auxiliary contact block
AF09, AF12, AF16
+ CAL4-11 2-pole auxiliary contact block
102.5 4.04"
110.5 4.35"
71 2.80"
10 0.39"
45 1.77"
AF09, AF12, AF16
+ CA4 4-pole auxiliary contact block
102.5 4.04"
ø 4.2 0.17"
AF09, AF12, AF16
+ VEM4 mechanical and electrical interlock set
Note: contactor lateral distance to grounded component 2 mm 0.08" min.
20 | ABB
ø
0.17"
5 4.2
0.20"
2x
M4 8-32 UNC
70 2.76"
5.5 0.22"
80 3.15" 2 x
M4 8-32 UNC
5 0.20"
80 3.15"
70 2.76"
5.5 0.22"
10 0.39"
5.5 0.22"
60 2.36"
35 mm EN/IEC 60715
35 mm EN/IEC 60715
91.5 3.60"
91.5 3.60"
5.5 0.22"
102.5 4.04"
0.39"
71102.80"
5 0.20"
71 2.80"
60 2.36"
43 1.69"
90 3.54"
5.5 0.22"
AF09, AF12, AF16
+ CAT4 2-pole auxiliary contact and coil terminal block
43 1.69"
90 3.54"
35 mm EN/IEC 60715
5.5 0.22"
10 0.39"
5.5 0.22"
80 3.15"
43 1.69"
80 3.15"
35 mm EN/IEC 60715
6 0.24"
5.5 0.22"
5 0.20"
AF09, AF12, AF16
+ VEM4 mechanical and electrical interlock set
43 1.69"
71 2.80"
45 1.77"
AF26 ... AF38 3-pole Contactors
AC / DC Operated - with Screw Terminals
Catalogue Page 1SBC 101 091 S0201
Dimensions mm, inches
77 3.03"
ø 4.2 0.17"
70 2.76"
10 0.39"
5 0.20"
10 0.39"
2x
M4 8-32 UNC
5 0.20"
5.5 0.22"
35 1.38"
2x
M4 8-32 UNC
70 2.76"
5.5 0.22"
ø 4.2 0.17"
60 2.36"
35 mm EN/IEC 60715
6 0.24"
35 mm EN/IEC 60715
80 3.15"
6 0.24"
80 3.15"
35 1.38"
5.5 0.22"
5.5 0.22"
60 2.36"
71 2.80"
45 1.77"
80 3.15"
5 0.20"
86 3.39"
45 1.77"
5 0.20"
AF26, AF30, AF38
AF26, AF30, AF38
86 3.39"
119.5 4.70"
45 1.77"
80 3.15"
10 0.39"
12 0.47"
80 3.15"
45 1.77"
80 3.15"
5.5 0.22"
35 mm EN/IEC 60715
6 0.24"
5.5 0.22"
43 1.69"
80 3.15"
35 mm EN/IEC 60715
6 0.24"
5.5 0.22"
5.5 0.22"
10 0.39"
AF26, AF30, AF38
+ CA4, CC4 1-pole auxiliary contact block
AF26, AF30, AF38
+ CAL4-11 2-pole auxiliary contact block
111.5 4.39"
119.5 4.70"
10 0.39"
45 1.77"
AF26, AF30, AF38
+ CA4 4-pole auxiliary contact block
35 mm EN/IEC 60715
80 3.15"
60 2.36"
60 2.36"
5.5 0.22"
43 1.69"
5.5 0.22"
ø 4.2 0.17"
AF26, AF30, AF38
+ VEM4 mechanical and electrical interlock set
80 3.15" 2 x
M4 8-32 UNC
4.2 0.17"
5ø 0.20"
2x
M4 8-32 UNC
70 2.76"
10 0.39"
5.5 0.22"
35 mm EN/IEC 60715
35 mm EN/IEC 60715
91.5 3.60"
111.5 4.39"
80 10
3.15"
0.39"
5 0.20"
80 3.15"
70 2.76"
111.5 4.39"
90 3.54"
5.5 0.22"
91.5 3.60"
5.5 0.22"
AF26, AF30, AF38
+ CAT4 2-pole auxiliary contact and coil terminal block
43 1.69"
90 3.54"
10 0.39"
5.5 0.22"
80 3.15"
43 1.69"
80 3.15"
35 mm EN/IEC 60715
6 0.24"
5.5 0.22"
5.5 0.22"
80 3.15"
43 1.69"
80 3.15"
5 0.20"
45 1.77"
5 0.20"
AF26, AF30, AF38
+ VEM4 mechanical and electrical interlock set
Note: contactor lateral distance to grounded component 2 mm 0.08" min.
ABB | 21