AF305-30-11-11

AF305-30-11-11

  • 厂商:

    ABB

  • 封装:

  • 描述:

    ABB - AF305-30-11-11 - Contactor, 305 A, DIN Rail, 1 kV, 3PST-NO, 3 Pole, 90 kW

  • 数据手册
  • 价格&库存
AF305-30-11-11 数据手册
AF305-30-11-11 24-60V 50/60Hz / DC General Information Extended Product Type: Product ID: EAN: Catalog Description: Long Description: AF305-30-11-11 24-60V 50/60Hz / DC 1SFL587002R1111 7320500481707 AF305-30-11-11 Contactor A 3-phase Contactor suitable for various applications such as Motor starting, Isolation, Bypass and Distribution application up to max 1000 V. Operated with wide control voltage range 24-60 V, 50 and 60 Hz, 20-60 V DC Categories Products » Low Voltage Products and Systems » Control Products » Contactors » Block Contactors Ordering Minimum Order Quantity: Customs Tariff Number: EAN: 1 piece 85364900 7320500481707 Dimensions Product Net Depth: Product Net Height: Product Net Weight: Product Net Width: 180.0 mm 225.0 mm 4.640 kg 140.0 mm Container Information Package Level 1 Width: Package Level 1 Length: Package Level 1 Height: Package Level 1 Gross Weight: Package Level 1 EAN: Package Level 1 Units: 223 mm 175 mm 270 mm 5.31 kg 7320500481707 1 piece Technical Number of Main Contacts NC: Number of Auxiliary Contacts NO: Number of Auxiliary Contacts NC: Rated Operational Voltage: Rated Frequency (f): Conventional Free-air Thermal Current (Ith): Rated Operational Current AC-1 (Ie): 0 1 1 Main Circuit 1000 V Main Circuit 50/60 Hz acc. to IEC 60947-4-1, Open Contactors q = 40 °C 500 A (690 V) 55 °C 400 A (690 V) 40 °C 500 A (1000 V) 40 °C 375 A (1000 V) 55 °C 325 A (690 V) 70 °C 325 A (1000 V) 70 °C 260 A Rated Operational Current AC-3 (Ie): (1000 V) 55 °C 100 A (415 V) 55 °C 305 A (690 V) 55 °C 290 A (220 / 230 / 240 V) 55 °C 305 A (440 V) 55 °C 305 A (380 / 400 V) 55 °C 305 A (500 V) 55 °C 290 A Rated Operational Power AC-3 (Pe): (500 V) 200 kW (1000 V) 132 kW (690 V) 250 kW (220 / 230 / 240 V) 90 kW (380 / 400 V) 160 kW (440 V) 160 kW (415 V) 160 kW Rated Breaking Capacity AC-3 acc. 8 x Ie AC-3 to IEC 60947-4-1: Rated Making Capacity AC-3 acc. to 10 x Ie AC-3 IEC 60947-4-1: Short-Circuit Protective Devices: gG Type Fuses 500 A Rated Short-time Withstand Current at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 2440 A (Icw): at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 1409 A Maximum Breaking Capacity: Maximum Electrical Switching Frequency: Rated Operational Current DC-1 (Ie): Rated Operational Current DC-3 (Ie): Rated Operational Current DC-5 (Ie): Rated Insulation Voltage (Ui): Rated Impulse Withstand Voltage (Uimp): Mechanical Durability: Maximum Mechanical Switching Frequency: Coil Operating Limits: Rated Control Circuit Voltage (Uc): Coil Consumption: Operate Time: Connecting Capacity Main Circuit: Connecting Capacity Auxiliary Circuit: Degree of Protection: Terminal Type: Number of Main Contacts NO: at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 500 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 3050 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 996 A cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 4600 A cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 3800 A AC-3 300 cycles per hour AC-1 300 cycles per hour AC-2 / AC-4 150 cycles per hour (110 V) 2 Poles in Series, 40 °C 400 A (220 V) 3 Poles in Series, 40 °C 400 A (110 V) 2 Poles in Series, 40 °C 400 A (220 V) 3 Poles in Series, 40 °C 400 A (110 V) 2 Poles in Series, 40 °C 400 A (220 V) 3 Poles in Series, 40 °C 400 A acc. to UL/CSA 600 V acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V Main Circuit 8 kV 5 million 300 cycles per hour (acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C) °C 60 Hz 24…60 V 50 Hz 24…60 V DC Operation 20…60 V Pull-in at Max. Rated Control Circuit Voltage 60 Hz 475 V·A Holding at Max. Rated Control Circuit Voltage DC 3 W Holding at Max. Rated Control Circuit Voltage 50 Hz 8.5 V·A Pull-in at Max. Rated Control Circuit Voltage DC 400 W Pull-in at Max. Rated Control Circuit Voltage 50 Hz 475 V·A Holding at Max. Rated Control Circuit Voltage 60 Hz 8.5 V·A Between Coil Energization and NO Contact Closing 25…55 ms Between Coil De-energization and NO Contact Opening 37…47 ms Rigid Al-Cable 1x185…240 mm² Flexible 2x70…185 mm² Rigid Cu-Cable 1x6…300 mm² Solid 2x1…4 mm² Flexible with Insulated Ferrule 2x0.75…2.5 mm² Stranded 2x1…4 mm² Flexible 2x0.75…2.5 mm² Flexible with Ferrule 2x0.75…2.5 mm² acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00 Main Circuit: Bars 3 Environmental Maximum Operating Altitude Permissible: RoHS Status: Ambient Air Temperature: 3000 m Following EU Directive 2002/95/EC August 18, 2005 and amendment Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25…+50 °C Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40…+70 °C Close to Contactor for Storage -40…+70 °C Technical UL/CSA General Use Rating UL/CSA: Horsepower Rating UL/CSA: Maximum Operating Voltage UL/CSA: (600 V AC) 400 A (208 V AC) Three Phase 100 Hp (440 ... 480 V AC) Three Phase 250 Hp (550 ... 600 V AC) Three Phase 300 Hp (220 ... 240 V AC) Three Phase 125 Hp (200 V AC) Three Phase 100 Hp Main Circuit 600 V Certificates and Declarations (Document Number) Instructions and Manuals: CB Certificate: Data Sheet, Technical Information: Declaration of Conformity - CE: RINA Certificate: RoHS Information: 1SFC100008M0201 SE-73043M1 1SFC101070D0201 2CMT004749 ELE060313XG/002 1SFC101055D0202 Classifications E-nummer: ETIM 4: ETIM 5: UNSPSC: Object Classification Code: 3210161 EC000066 - Magnet contactor, AC-switching EC000066 - Magnet contactor, AC-switching 39121529 Q
AF305-30-11-11 价格&库存

很抱歉,暂时无法提供与“AF305-30-11-11”相匹配的价格&库存,您可以联系我们找货

免费人工找货