AF40-30-00-13

AF40-30-00-13

  • 厂商:

    ABB

  • 封装:

  • 描述:

    ABB - AF40-30-00-13 - Contactor, 40 A, DIN Rail, 690 V, 3PST-NO, 3 Pole, 18.5 kW

  • 数据手册
  • 价格&库存
AF40-30-00-13 数据手册
AF40-30-00-13 General Information Extended Product Type: Product ID: EAN: Catalog Description: Long Description: AF40-30-00-13 1SBL347001R1300 3471523132030 AF40-30-00-13 100-250V50/60HZ-DC Contactor AF40 contactors are used for controlling power circuits up to 690 V AC and 220 V DC. They are mainly used for controlling 3-phase motors, non-inductive or slightly inductive loads. AF... contactors include an electronic coil interface accepting a wide control voltage Uc min. ... Uc max. Only four coils cover control voltages between 24...500 V 50/60 Hz or 20...500 V DC. AF contactors can manage large control voltage variations. One coil can be used for different control voltages used worldwide without any coil change. AF contactors have built-in surge protection and do not require additional surge suppressors. The AF... series 1-stack 3-pole contactors are of the block type design. - Main poles and auxiliary contact blocks: 3 main poles, front and side-mounted add-on auxiliary contact blocks (mechanically-linked auxiliary contacts compliant with Annex L of IEC 60947-5-1. N.C. mirror contacts compliant with Annex F of IEC 60947-4-1) - Control circuit: AC or DC operated - Accessories: a wide range of accessories is available. Categories Products » Low Voltage Products and Systems » Control Products » Contactors » Block Contactors Ordering Minimum Order Quantity: Customs Tariff Number: EAN: 1 piece 85369085 3471523132030 Dimensions Product Net Depth: Product Net Height: Product Net Weight: Product Net Width: 111 mm 125.5 mm 0.950 kg 55 mm Container Information Package Level 1 Width: Package Level 1 Length: Package Level 1 Height: Package Level 1 Gross Weight: Package Level 1 EAN: Package Level 2 Units: Package Level 2 Width: Package Level 2 Length: Package Level 2 Height: Package Level 3 Units: Package Level 1 Units: 150 mm 150 mm 97 mm 1.05 kg 3471523132030 10 piece 250 mm 300 mm 300 mm 240 piece 1 piece Technical Number of Main Contacts NC: Number of Auxiliary Contacts NO: Number of Auxiliary Contacts NC: Rated Operational Voltage: Rated Frequency (f): Conventional Free-air Thermal Current (Ith): Rated Operational Current AC-1 (Ie): 0 0 0 Main Circuit 690 V Main Circuit 50 / 60 Hz acc. to IEC 60947-4-1, Open Contactors q = 40 °C 105 A (690 V) 40 °C 70 A (690 V) 60 °C 60 A (690 V) 70 °C 50 A Rated Operational Current AC-3 (Ie): (220 / 230 / 240 V) 60 °C 40 A (380 / 400 V) 60 °C 40 A (415 V) 60 °C 40 A (440 V) 60 °C 40 A (500 V) 60 °C 35 A (690 V) 60 °C 25 A Rated Operational Power AC-3 (Pe): (220 / 230 / 240 V) 11 kW (380 / 400 V) 18.5 kW (400 V) 18.5 kW (415 V) 22 kW (440 V) 22 kW (500 V) 22 kW (690 V) 22 kW Rated Short-time Withstand Current at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 600 A (Icw): at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 110 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 350 A Maximum Breaking Capacity: cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 950 A cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 600 A Maximum Electrical Switching AC-1 600 cycles per hour Frequency: AC-2 / AC-4 150 cycles per hour AC-3 1200 cycles per hour Rated Insulation Voltage (Ui): acc. to UL/CSA 600 V acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V Rated Impulse Withstand Voltage 6 kV (Uimp): Maximum Mechanical Switching 3600 cycles per hour Frequency: Rated Control Circuit Voltage (Uc): 50 Hz 100 ... 250 V 60 Hz 100 ... 250 V DC Operation 100 ... 250 V Operate Time: Between Coil De-energization and NC Contact Closing 19 ... 105 ms Between Coil De-energization and NO Contact Opening 17 ... 100 ms Between Coil Energization and NC Contact Opening 38 ... 95 ms Between Coil Energization and NO Contact Closing 42 ... 100 ms Connecting Capacity Main Circuit: Flexible with Insulated Ferrule 1/2x 4...35 mm² Flexible with Ferrule 1/2x 4...35 mm² Rigid 1/2x 6...35 mm² Connecting Capacity Control Circuit: Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² Rigid 1/2x 1 ... 2.5 mm² Wire Stripping Length: Main Circuit 16 mm Degree of Protection: acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10 Terminal Type: Screw Terminals Number of Main Contacts NO: 3 Environmental Climatic Withstand: Maximum Operating Altitude Permissible: Resistance to Vibrations acc. to IEC 60068-2-6: Resistance to Shock acc. to IEC 60068-2-27: Ambient Air Temperature: Category B according to IEC 60947-1 Annex Q 3000 m 5 ... 300 Hz 3 g closed position / 3 g open position Closed, Shock Direction: A 25 g Closed, Shock Direction: B1 25 g Closed, Shock Direction: B2 15 g Closed, Shock Direction: C1 25 g Closed, Shock Direction: C2 25 g Open, Shock Direction: B1 5 g Close to Contactor for Storage -60...+80 °C Close to Contactor Fitted with Thermal O/L Relay -25 ... +60 °C Close to Contactor without Thermal O/L Relay -40 ... +70 °C Technical UL/CSA General Use Rating UL/CSA: Horsepower Rating UL/CSA: Tightening Torque UL/CSA: (600 V AC) 60 A (120 V AC) Single Phase 3 Hp (240 V AC) Single Phase 7-1/2 Hp (200 ... 208 V AC) Three Phase 10 Hp (220 ... 240 V AC) Three Phase 15 Hp (440 ... 480 V AC) Three Phase 30 Hp (550 ... 600 V AC) Three Phase 40 Hp Control Circuit 11 in·lb Main Circuit 35 in·lb Certificates and Declarations (Document Number) Instructions and Manuals: ABS Certificate: BV Certificate: CB Certificate: CCC Certificate: Data Sheet, Technical Information: 1SBC101036M6801 ABS_15-GE1349500-PDA_90682247 BV_2634H36994A CB_SE_77418 CCC_2012010304589737 1SBC100173C0201 Declaration of Conformity - CE: DNV Certificate: EAC Certificate: GL Certificate: LR Certificate: RINA Certificate: RMRS Certificate: RoHS Information: UL Certificate: UL Listing Card: 1SBD250000U1000 DNV-GL_E13871 EAC_RU C-FR ME77 B01010 DNV-GL_E13871 LRS_1300087E1 RINA_ELE084013XG RMRS_1400682124 1SBD251021E1000 UL_20130926-E312527_14_1 UL_E312527 Classifications E-nummer: ETIM 4: ETIM 5: ETIM 6: UNSPSC: Object Classification Code: 3210033 EC000066 - Magnet contactor, AC-switching EC000066 - Magnet contactor, AC-switching EC000066 - Power contactor, AC switching 39121529 Q
AF40-30-00-13 价格&库存

很抱歉,暂时无法提供与“AF40-30-00-13”相匹配的价格&库存,您可以联系我们找货

免费人工找货