AF96-30-00-13 数据手册
AF96-30-00-13 General Information Extended Product Type: Product ID: EAN: Catalog Description: Long Description: AF96-30-00-13 1SBL407001R1300 3471523133235 AF96-30-00-13 100-250V50/60HZ-DC Contactor AF96 contactors are used for controlling power circuits up to 690 V AC and 220 V DC. They are mainly used for controlling 3-phase motors, non-inductive or slightly inductive loads. AF... contactors include an electronic coil interface accepting a wide control voltage Uc min. ... Uc max. Only four coils cover control voltages between 24...500 V 50/60 Hz or 20...500 V DC. AF contactors can manage large control voltage variations. One coil can be used for different control voltages used worldwide without any coil change. AF contactors have built-in surge protection and do not require additional surge suppressors. The AF... series 1-stack 3-pole contactors are of the block type design. - Main poles and auxiliary contact blocks: 3 main poles, front and side-mounted add-on auxiliary contact blocks (mechanically-linked auxiliary contacts compliant with Annex L of IEC 60947-5-1. N.C. mirror contacts compliant with Annex F of IEC 60947-4-1) - Control circuit: AC or DC operated - Accessories: a wide range of accessories is available. Categories Products » Low Voltage Products and Systems » Control Products » Contactors » Block Contactors Ordering Minimum Order Quantity: Customs Tariff Number: EAN: 1 piece 85369085 3471523133235 Dimensions Product Net Depth: Product Net Height: Product Net Weight: Product Net Width: 116 mm 125.5 mm 1.170 kg 70 mm Container Information Package Level 1 Width: Package Level 1 Length: Package Level 1 Height: Package Level 1 Gross Weight: Package Level 1 EAN: Package Level 2 Units: Package Level 2 Width: Package Level 2 Length: Package Level 2 Height: Package Level 3 Units: Package Level 1 Units: 150 mm 150 mm 103 mm 1.29 kg 3471523133235 8 piece 250 mm 300 mm 300 mm 192 piece 1 piece Technical Number of Main Contacts NC: Number of Auxiliary Contacts NO: Number of Auxiliary Contacts NC: Rated Operational Voltage: Rated Frequency (f): Conventional Free-air Thermal Current (Ith): Rated Operational Current AC-1 (Ie): 0 0 0 Main Circuit 690 V Main Circuit 50 / 60 Hz acc. to IEC 60947-4-1, Open Contactors q = 40 °C 130 A (690 V) 40 °C 130 A (690 V) 60 °C 105 A (690 V) 70 °C 90 A Rated Operational Current AC-3 (Ie): (220 / 230 / 240 V) 60 °C 96 A (380 / 400 V) 60 °C 96 A (415 V) 60 °C 96 A (440 V) 60 °C 96 A (500 V) 60 °C 80 A (690 V) 60 °C 57 A (1000 V) 60 °C 30 A Rated Operational Power AC-3 (Pe): (220 / 230 / 240 V) 25 kW (380 / 400 V) 45 kW (400 V) 45 kW (415 V) 55 kW (440 V) 55 kW (500 V) 55 kW (690 V) 55 kW Rated Short-time Withstand Current at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 780 A (Icw): at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 140 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 300 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1200 A at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 450 A Maximum Breaking Capacity: cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1150 A cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 750 A Maximum Electrical Switching AC-1 600 cycles per hour Frequency: AC-2 / AC-4 150 cycles per hour AC-3 1200 cycles per hour Rated Insulation Voltage (Ui): acc. to UL/CSA 600 V acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V Rated Impulse Withstand Voltage 8 kV (Uimp): Maximum Mechanical Switching 3600 cycles per hour Frequency: Rated Control Circuit Voltage (Uc): 50 Hz 100 ... 250 V 60 Hz 100 ... 250 V DC Operation 100 ... 250 V Operate Time: Between Coil De-energization and NC Contact Closing 19 ... 105 ms Between Coil De-energization and NO Contact Opening 17 ... 100 ms Between Coil Energization and NC Contact Opening 38 ... 95 ms Between Coil Energization and NO Contact Closing 42 ... 100 ms Connecting Capacity Main Circuit: Flexible with Insulated Ferrule 1/2x 6...50 mm² Flexible with Ferrule 1/2x 6...50 mm² Rigid 1x 6...70 mm² Rigid 2x 6...50 mm² Connecting Capacity Control Circuit: Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² Rigid 1/2x 1 ... 2.5 mm² Wire Stripping Length: Main Circuit 17 mm Degree of Protection: acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10 Terminal Type: Screw Terminals Number of Main Contacts NO: 3 Environmental Climatic Withstand: Maximum Operating Altitude Permissible: Resistance to Vibrations acc. to IEC 60068-2-6: Resistance to Shock acc. to IEC 60068-2-27: Ambient Air Temperature: Category B according to IEC 60947-1 Annex Q 3000 m 5 ... 300 Hz 3 g closed position / 3 g open position Closed, Shock Direction: A 25 g Closed, Shock Direction: B1 25 g Closed, Shock Direction: B2 15 g Closed, Shock Direction: C1 25 g Closed, Shock Direction: C2 25 g Open, Shock Direction: B1 5 g Close to Contactor for Storage -60...+80 °C Close to Contactor Fitted with Thermal O/L Relay -25 ... +60 °C Close to Contactor without Thermal O/L Relay -40 ... +70 °C Technical UL/CSA Horsepower Rating UL/CSA: Tightening Torque UL/CSA: (120 V AC) Single Phase 7-1/2 Hp (240 V AC) Single Phase 20 Hp (200 ... 208 V AC) Three Phase 30 Hp (220 ... 240 V AC) Three Phase 30 Hp (440 ... 480 V AC) Three Phase 60 Hp (550 ... 600 V AC) Three Phase 75 Hp Control Circuit 11 in·lb Main Circuit 53 in·lb Certificates and Declarations (Document Number) Instructions and Manuals: ABS Certificate: BV Certificate: CB Certificate: CCC Certificate: Data Sheet, Technical Information: 1SBC101036M6801 ABS_15-GE1349500-PDA_90682247 BV_2634H36994A CB_SE-77417M1 CCC_2013010304646569 1SBC100173C0201 Declaration of Conformity - CE: DNV Certificate: EAC Certificate: GL Certificate: LR Certificate: RINA Certificate: RMRS Certificate: RoHS Information: UL Certificate: 1SBD250000U1000 DNV-GL_E13871 EAC_RU C-FR ME77 B01010 DNV-GL_E13871 LRS_1300087E1 RINA_ELE084013XG RMRS_1400682124 1SBD251021E1000 UL_20130926-E312527_14_1 Classifications E-nummer: ETIM 4: ETIM 5: ETIM 6: UNSPSC: Object Classification Code: 3210057 EC000066 - Magnet contactor, AC-switching EC000066 - Magnet contactor, AC-switching EC000066 - Power contactor, AC switching 39121529 Q
AF96-30-00-13
1. 物料型号: AF96-30-00-13,产品ID为1SBL407001R1300。

2. 器件简介: AF96接触器用于控制高达690V交流和220V直流的功率电路,主要用于控制三相电机、非感性或轻微感性负载。它们包括一个电子线圈接口,接受广泛的控制电压,具有内置的浪涌保护功能。

3. 引脚分配: 3个主极,配有前侧和侧面安装的附加辅助接触块(机械连接辅助接触符合IEC 60947-5-1附录L,N.C.镜像接触符合IEC 60947-4-1附录F)。

4. 参数特性: - 额定操作电压:主电路690V,频率50/60Hz。 - 额定操作电流:AC-1(690V)在40°C时为130A,在60°C和70°C时分别降低至105A和90A。 - 短时耐受电流:在40°C环境温度下,从冷态10秒780A,15分钟140A,1分钟300A,1秒1200A,30秒450A。

5. 功能详解: AF接触器可以管理大的控制电压变化,一个线圈可用于全球不同控制电压,无需更换线圈。它们还具有内置的浪涌保护和多种可用的配件。

6. 应用信息: 主要用于控制三相电机和非感性或轻微感性负载。

7. 封装信息: 产品净尺寸为116mm(深) x 125.5mm(高) x 70mm(宽),净重1.170kg。包装信息包括单件和多件的尺寸和毛重。
AF96-30-00-13 价格&库存