0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
APTS012A0X3-SRZ

APTS012A0X3-SRZ

  • 厂商:

    ABB

  • 封装:

    SMD10 模块

  • 描述:

    非隔离 PoL 模块 直流转换器 1 输出 0.7 ~ 5.5V 12A 4.5V - 14V 输入

  • 数据手册
  • 价格&库存
APTS012A0X3-SRZ 数据手册
GE Data Sheet 12V MicroTLynxTM 12A: Non-Isolated DC-DC Power Module 4.5Vdc –14Vdc input; 0.69Vdc to 5.5Vdc output; 12A Output Current Features RoHS Compliant EZ-SEQUENCETM Applications ▪ Compliant to RoHS Directive 2011/65/EU and amended Directive (EU) 2015/863 ▪ Compliant to REACH Directive (EC) No 1907/2006 ▪ Compatible in a Pb-free or SnPb reflow environment (Z versions) ▪ DOSA Based ▪ Wide Input voltage range (4.5Vdc-14Vdc) ▪ Output voltage programmable from 0.69Vdc to 5.5 Vdc via external resistor ▪ Tunable LoopTM to optimize dynamic output voltage response ▪ Flexible output voltage sequencing EZ-SEQUENCE (APTS versions) ▪ Fixed switching frequency and ability to synchronize with external clock ▪ Distributed power architectures ▪ Intermediate bus voltage applications ▪ Telecommunications equipment ▪ Output overcurrent protection (non-latching) ▪ Servers and storage applications ▪ Overtemperature protection ▪ Networking equipment ▪ Remote On/Off ▪ Industrial equipment ▪ Remote Sense ▪ Power Good signal ▪ Fixed switching frequency ▪ Ability to sink and source current ▪ Small size: 20.3 mm x 11.4 mm x 8.5 mm (0.8 in x 0.45 in x 0.334 in) ▪ Wide operating temperature range [-40°C to 105°C(Ruggedized: -D), 85°C(Regular)] ▪ Ruggedized (-D) version able to withstand high levels of shock and vibration Vin+ VIN PGOOD Vout+ VOUT SEN SE MODULE RTUNE SEQ Cin CTUNE Q1 ON /OFF Co TR IM GN D RTrim ▪ ANSI/UL* 62368-1 and CAN/CSA† C22.2 No. 62368-1 Recognized, DIN VDE‡ 0868-1/A11:2017 (EN623681:2014/A11:2017 ▪ ISO** 9001 and ISO 14001 certified manufacturing facilities Description The 12V Micro TLynxTM series of power modules are non-isolated dc-dc converters that can deliver up to 12A of output current. These modules operate over a wide range of input voltage (VIN = 4.5Vdc-14Vdc) and provide a precisely regulated output voltage from 0.69Vdc to 5.5Vdc, programmable via an external resistor. The new Ruggedized version (-D) is capable of operation up to 105°C and can withstand high levels of shock and vibration. Features include frequency synchronization, remote On/Off, adjustable output voltage, over current and overtemperature protection, power good and output voltage sequencing. A new feature, the Tunable LoopTM, allows the user to optimize the dynamic response of the converter to match the load with reduced amount of output capacitance leading to savings on cost and PWB area. * UL is a registered trademark of Underwriters Laboratories, Inc. † CSA is a registered trademark of Canadian Standards Association. VDE is a trademark of Verband Deutscher Elektrotechniker e.V. ** ISO is a registered trademark of the International Organization of Standards ‡ August 6, 2020 ©2017 General Electric Company. All rights reserved. GE Data Sheet 12V MicroTLynxTM 12A: Non-Isolated DC-DC Power Modules 4.5Vdc –14Vdc input; 0.69Vdc to 5.5Vdc output; 12A Output Current Absolute Maximum Ratings Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings only, functional operation of the device is not implied at these or any other conditions in excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect the device reliability. Parameter Device Symbol Min Max Unit All VIN -0.3 15 Vdc Voltage on SEQ terminal All VSEQ -0.3 VIN Vdc Voltage on SYNC terminal All VSYNC -0.3 12 Vdc Voltage on PG terminal All VPG -0.3 6 Vdc Input Voltage Continuous Operating Ambient Temperature (see Thermal Considerations section) All TA -40 85 °C -D version TA -40 105 °C All Tstg -55 125 °C Storage Temperature Electrical Specifications Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions. Parameter Device Symbol Min Typ Max Unit Operating Input Voltage All VIN 4.5 ⎯ 14.0 Vdc Maximum Input Current All IIN,max 11.5 Adc (VIN = 10.0Vdc, IO = 0, module enabled) VO,set = 0.69 Vdc IIN,No load 26 mA (VIN = 12.0Vdc, IO = 0, module enabled) VO,set = 3.3Vdc IIN,No load 60 mA All IIN,stand-by 1.2 mA Inrush Transient All I2t Input Reflected Ripple Current, peak-to-peak (5Hz to 20MHz, 1μH source impedance; VIN =0 to 14V, IO= IOmax ; See Test Configurations) All 70 mAp-p Input Ripple Rejection (120Hz) All 45 dB (VIN=4.5V to 14V, IO=IO, max ) Input No Load Current Input Stand-by Current (VIN = 12.0Vdc, module disabled) 1 A2s CAUTION: This power module is not internally fused. An input line fuse must always be used. This power module can be used in a wide variety of applications, ranging from simple standalone operation to an integrated part of sophisticated power architecture. To preserve maximum flexibility, internal fusing is not included; however, to achieve maximum safety and system protection, always use an input line fuse. The safety agencies require a fast-acting fuse with a maximum rating of 15A (see Safety Considerations section). Based on the information provided in this data sheet on inrush energy and maximum dc input current, the same type of fuse with a lower rating can be used. Refer to the fuse manufacturer’s data sheet for further information. August 6, 2020 ©2017 General Electric Company. All rights reserved. Page 2 GE Data Sheet 12V MicroTLynxTM 12A: Non-Isolated DC-DC Power Modules 4.5Vdc –14Vdc input; 0.69Vdc to 5.5Vdc output; 12A Output Current Electrical Specifications (continued) Parameter Device Symbol Min Output Voltage Set-point All VO, set -1.5 Output Voltage All VO, set -2.5 All VO 0.69 Typ ⎯ Max Unit +1.5 % VO, set +2.5 % VO, set 5.5 Vdc (Over all operating input voltage, resistive load, and temperature conditions until end of life) Adjustment Range (elected by an external resistor) (Some output voltages may not be possible depending on the input voltage – see Feature Descriptions Section) Output Regulation (for VO ≥ 2.5Vdc) Line (VIN=VIN, min to VIN, max) All ⎯ +0.4 % VO, set Load (IO=IO, min to IO, max) All ⎯ 10 mV Line (VIN=VIN, min to VIN, max) All ⎯ 10 mV Load (IO=IO, min to IO, max) All ⎯ 5 mV Temperature (Tref=TA, min to TA, max) All ⎯ 0.5 % VO, set 0.5 Vdc Output Regulation (for VO < 2.5Vdc) Remote Sense Range All Output Ripple and Noise on nominal output (VIN=VIN, nom and IO=IO, min to IO, max Co = 0.1μF // 10 μF ceramic capacitors) Peak-to-Peak (5Hz to 20MHz bandwidth) All ⎯ 65 80 mVpk-pk RMS (5Hz to 20MHz bandwidth) All ⎯ 23 28 mVrms External Capacitance 1 Without the Tunable LoopTM All CO, max 0 ⎯ 100 μF ESR ≥ 0.15 mΩ All CO, max 0 ⎯ 1000 μF ⎯ 5000 μF 12 Adc ESR ≥ 1 mΩ With the Tunable LoopTM ESR ≥ 10 mΩ All CO, max 0 Output Current All Io 0 Output Current Limit Inception (Hiccup Mode ) All IO, lim 150 % Io,max Output Short-Circuit Current All IO, s/c 2 Adc VIN= 10Vdc, TA=25°C VO, set = 0.69Vdc η 76.0 % VIN= 12Vdc, TA=25°C VO, set = 1.2Vdc η 83.0 % IO=IO, max , VO= VO,set VO,set = 1.8Vdc η 87.6 % VO,set = 2.5Vdc η 90.2 % VO,set = 3.3Vdc η 92.2 % VO,set = 5.0Vdc η 94.3 % (VO≤250mV) ( Hiccup Mode ) Efficiency External capacitors may require using the new Tunable LoopTM feature to ensure that the module is stable as well as getting the best transient response. See the Tunable LoopTM section for details. August 6, 2020 ©2017 General Electric Company. All rights reserved. Page 3 GE Data Sheet 12V MicroTLynxTM 12A: Non-Isolated DC-DC Power Modules 4.5Vdc –14Vdc input; 0.69Vdc to 5.5Vdc output; 12A Output Current Electrical Specifications (continued) Parameter Switching Frequency Device Symbol Min Typ Max Unit All fsw ⎯ 500 ⎯ kHz 600 kHz Frequency Synchronization Synchronization Frequency Range 520 High-Level Input Voltage All VIH Low-Level Input Voltage All VIL 0.8 V VSYNC=2.5V ISYNC 1 mA All tSYNC 250 ns All tSYNC_SH 250 ns Peak Deviation All Vpk ⎯ 360 Settling Time (Vo
APTS012A0X3-SRZ 价格&库存

很抱歉,暂时无法提供与“APTS012A0X3-SRZ”相匹配的价格&库存,您可以联系我们找货

免费人工找货