GE
Data Sheet
ATL010A0X43-SR: 12V SMT Non-Isolated DC-DC Power Modules
9Vdc – 18Vdc input; 0.75Vdc to 5.5Vdc output; 10A Output Current
Features
RoHS Compliant
Compliant to RoHS EU Directive 2011/65/EU (-Z
versions)
Compliant to RoHS EU Directive 2011/65/EU under
exemption 7b (Lead solder exemption). Exemption 7b
will expire after June 1, 2016 at which time this product
will no longer be RoHS compliant (non-Z versions)
Flexible output voltage sequencing EZ-SEQUENCE
Delivers up to 10A of output current
High efficiency – 93% at 3.3V full load (VIN = 12.0V)
Small size and low profile:
33.00 mm x 13.46 mm x 8.28 mm
(1.300 in x 0.530 in x 0.326 in)
Applications
Distributed power architectures
Intermediate bus voltage applications
Telecommunications equipment
Servers and storage applications
Networking equipment
Low output ripple and noise
High Reliability:
Calculated MTBF = 15 M hours at 25oC Full-load
Output voltage programmable from 0.75 Vdc to 5.5
Vdc via external resistor
Line Regulation: 0.3% (typical)
Load Regulation: 0.4% (typical)
Temperature Regulation: 0.4% (typical)
Remote On/Off
Remote Sense
Output overcurrent protection (non-latching)
Overtemperature protection
Wide operating temperature range (-40°C to 85°C)
UL* 60950-1Recognized, CSA† C22.2 No. 60950-1-03
Certified, and VDE‡ 0805:2001-12 (EN60950-1) Licensed
ISO** 9001 and ISO 14001 certified manufacturing
facilities
Description
The ATL010A0X43-SR power modules are non-isolated dc-dc converters that can deliver up to 10A of output current with full
load efficiency of 93% at 3.3V output. These modules provide a precisely regulated output voltage programmable via an
external resistor from 0.75Vdc to 5.5Vdc over a wide range of input voltage (VIN = 9 – 18Vdc). The ATL010A0X43-SR series has
a sequencing feature, EZ-SEQUENCETM that enables designers to implement various types of output voltage sequencing when
powering multiple voltages on a board. Their open-frame construction and small footprint enable designers to develop costand space-efficient solutions. In addition to sequencing, standard features include remote On/Off, remote sense, output
voltage adjustment, over current and over temperature protection.
* UL is a registered trademark of Underwriters Laboratories, Inc.
†
CSA is a registered trademark of Canadian Standards Association.
VDE is a trademark of Verband Deutscher Elektrotechniker e.V.
** ISO is a registered trademark of the International Organization of Standards
‡
October 6, 2015
©2015 General Electric Company. All rights reserved.
GE
Data Sheet
ATL010A0X43-SR: 12V SMT Non-Isolated DC-DC Power Modules
9Vdc – 18Vdc input; 0.75Vdc to 5.5Vdc output; 10A Output Current
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings
only, functional operation of the device is not implied at these or any other conditions in excess of those given in the operations
sections of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect the device reliability.
Parameter
Device
Symbol
Min
Max
Unit
All
VIN
-0.3
18
Vdc
Sequencing Voltage
All
VSEQ
-0.3
ViN, Max
Vdc
Operating Ambient Temperature
All
TA
-40
85
°C
All
Tstg
-55
125
°C
Input Voltage
Continuous
(see Thermal Considerations section)
Storage Temperature
Electrical Specifications
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions.
Parameter
Device
Symbol
Min
Typ
Max
Unit
9.0
12.0
18.0
Vdc
7.0
Adc
Operating Input Voltage
All
VIN
Maximum Input Current
All
IIN,max
VO,set = 0.75 Vdc
IIN,No load
40
mA
VO,set = 5.0Vdc
IIN,No load
100
mA
All
IIN,stand-by
2.0
mA
Inrush Transient
All
I2t
Input Reflected Ripple Current, peak-to-peak
(5Hz to 20MHz, 1μH source impedance; VIN, min to VIN,
max, IO= IOmax ; See Test configuration section)
All
20
Input Ripple Rejection (120Hz)
All
30
(VIN= VIN, min to VIN, max, IO=IO, max VO,set = 5.5Vdc)
Input No Load Current
(VIN = 12.0Vdc, IO = 0, module enabled)
Input Stand-by Current
(VIN = 12.0Vdc, module disabled)
0.4
A 2s
mAp-p
dB
CAUTION: These power modules can be used in a wide variety of applications ranging from simple standalone operation to an
integrated part of sophisticated power architectures. To preserve maximum flexibility, no internal fuse has been provided. Also,
extensive safety testing has shown that no external fuse is required to protect the unit. However, it is still recommended that some
type of current-limiting power source be used to protect the module and evaluated in the end-use equipment.
October 6, 2015
©2015 General Electric Company. All rights reserved.
Page 2
GE
Data Sheet
ATL010A0X43-SR: 12V SMT Non-Isolated DC-DC Power Modules
9Vdc – 18Vdc input; 0.75Vdc to 5.5Vdc output; 10A Output Current
Electrical Specifications (continued)
Parameter
Output Voltage Set-point
Device
Symbol
Min
Typ
Max
Unit
All
VO, set
–2.0
+2.0
% VO, set
All
VO, set
–2.5%
+3.5%
% VO, set
All
VO
0.7525
5.5
Vdc
(VIN=IN, min, IO=IO, max, TA=25°C)
Output Voltage
(Over all operating input voltage, resistive load, and
temperature conditions until end of life)
Adjustment Range
Selected by an external resistor
Output Regulation
Line (VIN=VIN, min to VIN, max)
All
0.3
% VO, set
Load (IO=IO, min to IO, max)
All
0.4
% VO, set
Temperature (Tref=TA, min to TA, max)
All
0.4
% VO, set
RMS (5Hz to 20MHz bandwidth)
All
12
30
mVrms
Peak-to-Peak (5Hz to 20MHz bandwidth)
All
30
75
mVpk-pk
μF
Output Ripple and Noise on nominal output
(VIN=VIN, nom and IO=IO, min to IO, max
Cout = 1μF ceramic//10μFtantalum capacitors)
External Capacitance
ESR ≥ 1 mΩ
All
CO, max
1000
ESR ≥ 10 mΩ
All
CO, max
5000
μF
Output Current
All
Io
0
10
Adc
Output Current Limit Inception (Hiccup Mode )
All
IO, lim
200
% Io
Output Short-Circuit Current
All
IO, s/c
3
Adc
η
81.0
VIN= VIN, nom, TA=25°C
VO, set =
0 75Vdc
VO, set = 1.2Vdc
η
87.5
%
IO=IO, max , VO= VO,set
VO,set = 1.5Vdc
η
89.0
%
VO,set = 1.8Vdc
η
90.0
%
VO,set = 2.5Vdc
η
92.0
%
VO,set = 3.3Vdc
η
93.0
%
VO,set = 5.0Vdc
η
95.0
%
All
fsw
300
kHz
All
Vpk
200
mV
(VO≤250mV) ( Hiccup Mode )
Efficiency
Switching Frequency
%
Dynamic Load Response
(dIo/dt=2.5A/µs; VIN = VIN, nom; TA=25°C)
Load Change from Io= 50% to 100% of Io,max; 1μF
ceramic// 10 μF tantalum
Peak Deviation
Settling Time (Vo