GE
Data Sheet
Austin MiniLynxTM: SMT Non-Isolated DC-DC Power Modules
2.4Vdc –5.5Vdc input; 0.75Vdc to 3.63Vdc output; 3A Output Current
Features
RoHS Compliant
▪
Compliant to RoHS Directive 2011/65/EU and amended
Directive (EU) 2015/863
▪
Compliant to REACH Directive (EC) No 1907/2006
▪
Delivers up to 3A output current
▪
High efficiency – 94% at 3.3V full load (VIN = 5.0V)
▪
Small size and low profile:
20.3 mm x 11.4 mm x 7.27 mm
(0.80 in x 0.45 in x 0.286 in)
▪
Low output ripple and noise
▪
High Reliability:
Calculated MTBF = 11.9M hours at 25oC Full-load
Applications
▪
Constant switching frequency (300 kHz)
▪
Output voltage programmable from 0.75 Vdc to 3.63Vdc
via external resistor
▪
Distributed power architectures
▪
Intermediate bus voltage applications
▪
Line Regulation: 0.4% (typical)
▪
Telecommunications equipment
▪
Load Regulation: 0.4% (typical)
▪
Servers and storage applications
▪
Temperature Regulation: 0.4 % (typical)
▪
Networking equipment
▪
Remote On/Off
▪
Enterprise Networks
▪
Output overcurrent protection (non-latching)
▪
Latest generation IC’s (DSP, FPGA, ASIC) and
Microprocessor powered applications
▪
Wide operating temperature range (-40°C to 85°C)
▪
ANSI/UL* 62368-1 and CAN/ CSA† C22.2 No. 62368-1
Recognized, DIN VDE‡ 0868-1/A11:2017 (EN623681:2014/A11:2017)
▪
ISO** 9001 and ISO 14001 certified manufacturing
facilities
Description
Austin MiniLynxTM SMT (surface mount technology) power modules are non-isolated dc-dc converters that can deliver up to 3A
of output current with full load efficiency of 94.0% at 3.3V output. These modules provide a precisely regulated output voltage
programmable via an external resistor from 0.75Vdc to 3.63Vdc over a wide range of input voltage (VIN = 2.4 – 5.5Vdc). Their
open-frame construction and small footprint enable designers to develop cost- and space-efficient solutions.
*
UL is a registered trademark of Underwriters Laboratories, Inc.
CSA is a registered trademark of Canadian Standards Association.
‡
VDE is a trademark of Verband Deutscher Elektrotechniker e.V.
** ISO is a registered trademark of the International Organization of Standards
†
February 16, 2021
©2015 General Electric Company. All rights reserved.
GE
Data Sheet
Austin MiniLynxTM: SMT Non-Isolated DC-DC Power Modules
2.4Vdc – 5.5Vdc input; 0.75Vdc to 3.63Vdc output; 3A Output Current
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings only,
functional operation of the device is not implied at these or any other conditions in excess of those given in the operations sections of
the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect the device reliability.
Parameter
Input Voltage
Device
Symbol
Min
Max
Unit
All
VIN
-0.3
5.8
Vdc
All
TA
-40
85
°C
All
Tstg
-55
125
°C
Continuous
Operating Ambient Temperature
(see Thermal Considerations section)
Storage Temperature
Electrical Specifications
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions.
Parameter
Device
Symbol
Min
Typ
Max
Unit
2.4
⎯
5.5
Vdc
3.0
Adc
Operating Input Voltage
VO,set ≤ VIN – 0.5V
VIN
Maximum Input Current
All
IIN,max
VO,set = 0.75Vdc
IIN,No load
10
mA
VO,set = 3.3Vdc
IIN,No load
17
mA
All
IIN,stand-by
0.6
mA
Inrush Transient
All
I2t
Input Reflected Ripple Current, peak-to-peak
(5Hz to 20MHz, 1μH source impedance; VIN, min to VIN, max,
IO= IOmax ; See Test configuration section)
All
35
mAp-p
Input Ripple Rejection (120Hz)
All
30
dB
(VIN= VIN, min to VIN, max, IO=IO, max VO,set = 3.3Vdc)
Input No Load Current
(VIN = 5.0Vdc, IO = 0, module enabled)
Input Stand-by Current
(VIN = 5.0Vdc, module disabled)
0.04
A2s
CAUTION: This power module is not internally fused. An input line fuse must always be used.
This power module can be used in a wide variety of applications, ranging from simple standalone operation to being part of a complex
power architecture. To preserve maximum flexibility, internal fusing is not included, however, to achieve maximum safety and system
protection, always use an input line fuse. The safety agencies require a fast-acting fuse with a maximum rating of 6 A (see Safety
Considerations section). Based on the information provided in this data sheet on inrush energy and maximum dc input current, the
same type of fuse with a lower rating can be used. Refer to the fuse manufacturer’s data sheet for further information.
February 16, 2021
©2015 General Electric Company. All rights reserved.
Page 2
GE
Data Sheet
Austin MiniLynxTM: SMT Non-Isolated DC-DC Power Modules
2.4Vdc – 5.5Vdc input; 0.75Vdc to 3.63Vdc output; 3A Output Current
Electrical Specifications (continued)
Parameter
Output Voltage Set-point
Device
Symbol
Min
Typ
Max
Unit
All
VO, set
-2.0
VO, set
+2.0
% VO, set
All
VO, set
-3%
⎯
+3%
% VO, set
All
VO
0.7525
3.63
Vdc
(VIN=IN, min, IO=IO, max, TA=25°C)
Output Voltage
(Over all operating input voltage, resistive load, and
temperature conditions until end of life)
Adjustment Range
Selected by an external resistor
Output Regulation
Line (VIN=VIN, min to VIN, max)
All
⎯
0.4
⎯
% VO, set
Load (IO=IO, min to IO, max)
All
⎯
0.4
⎯
% VO, set
Temperature (Tref=TA, min to TA, max)
All
⎯
0.4
⎯
% VO, set
RMS (5Hz to 20MHz bandwidth)
All
⎯
10
15
mVrms
Peak-to-Peak (5Hz to 20MHz bandwidth)
All
⎯
25
50
mVpk-pk
Output Ripple and Noise on nominal output
(VIN=VIN, nom and IO=IO, min to IO, max
Cout = 1μF ceramic//10μFtantalum capacitors)
External Capacitance
ESR ≥ 1 mΩ
All
CO, max
⎯
⎯
1000
μF
ESR ≥ 10 mΩ
All
CO, max
⎯
⎯
5000
μF
Output Current
All
Io
0
3
Adc
Output Current Limit Inception (Hiccup Mode )
All
IO, lim
⎯
220
⎯
% Io
All
IO, s/c
⎯
2
⎯
Adc
η
81.5
%
VIN= VIN, nom, TA=25°C
VO,set =
0.75Vdc
VO, set = 1.2Vdc
η
87.0
%
IO=IO, max , VO= VO,set
VO,set = 1.5Vdc
η
89.0
%
VO,set = 1.8Vdc
η
90.0
%
VO,set = 2.5Vdc
η
93.0
%
(VO= 90% of VO, set)
Output Short-Circuit Current
(VO≤250mV) ( Hiccup Mode )
Efficiency
VO,set = 3.3Vdc
η
All
fsw
⎯
300
⎯
kHz
All
Vpk
⎯
250
⎯
mV
Settling Time (Vo