0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
DEL-KT3S4

DEL-KT3S4

  • 厂商:

    ABB

  • 封装:

  • 描述:

    SHUNT TRIP, T1/T3 CIRCUIT BREAKER

  • 数据手册
  • 价格&库存
DEL-KT3S4 数据手册
Product Selector Tmax Molded Case Circuit Breakers Molded Case Circuit Breakers Index Tmax Molded Case Circuit Breakers T1…T8 General information ............................................................................................ 1 T1…T8 Selection information.......................................................................................... 2 T1…T8 Catalogue number explanation........................................................................... 4 T1 100A ......................................................................................................................... 5 T2 100A ......................................................................................................................... 7 T3 225A ....................................................................................................................... 10 Ts3 225A ...................................................................................................................... 13 T4 250A ....................................................................................................................... 17 T5 400A / 600A ............................................................................................................ 23 T6 600A / 800A ............................................................................................................ 28 T7-T7M 1000A /1200A ................................................................................................ 31 T8V 1600A / 2000A / 2500A / 3000A ........................................................................... 41 T1…T6 Accessories ..................................................................................................... 47 T1…T2 Dimensions ...................................................................................................... 61 T3 Dimensions.............................................................................................................. 62 Ts3 Dimensions ............................................................................................................ 63 T4 Dimensions.............................................................................................................. 64 T5 Dimensions.............................................................................................................. 65 T6 Dimensions.............................................................................................................. 66 T7 Dimensions.............................................................................................................. 67 T8 Dimensions.............................................................................................................. 68 T1...T7 Variable depth handle dimensions.................................................................... .71 Molded Case Circuit Breakers Index Tmax Molded Case Circuit Breakers T1…T8 General information ............................................................................................ 1 T1…T8 Selection information.......................................................................................... 2 T1…T8 Catalogue number explanation........................................................................... 4 T1 100A ......................................................................................................................... 5 T2 100A ......................................................................................................................... 7 T3 225A ....................................................................................................................... 10 Ts3 225A ...................................................................................................................... 13 T4 250A ....................................................................................................................... 17 T5 400A / 600A ............................................................................................................ 23 T6 600A / 800A ............................................................................................................ 28 T7-T7M 1000A /1200A ................................................................................................ 31 T8V 1600A / 2000A / 2500A / 3000A ........................................................................... 41 T1…T6 Accessories ..................................................................................................... 47 T1…T2 Dimensions ...................................................................................................... 61 T3 Dimensions.............................................................................................................. 62 Ts3 Dimensions ............................................................................................................ 63 T4 Dimensions.............................................................................................................. 64 T5 Dimensions.............................................................................................................. 65 T6 Dimensions.............................................................................................................. 66 T7 Dimensions.............................................................................................................. 67 T8 Dimensions.............................................................................................................. 68 T1...T7 Variable depth handle dimensions.................................................................... .71 Tmax Molded Case Circuit Breakers Introduction ABB is once again demonstrating its commitment to new product development and its superiority in product technology. Never before has the industry seen such high performance, versatility and standardization in a range of molded case circuit breakers. The ABB Tmax line of circuit breakers, with a range up to 3000A, has several key features that go along with its very small size: • Double insulation – this construction characteristic allows for the CSA/ UL listed field installation of internal accessories without exposure to energized parts • Complete range of electrical and mechanical accessories • Positive operation – breakers from ABB ensure that the toggle indicates the precise position of the moving contacts. This guarantees safe and reliable signaling by the device • Installation – Tmax molded case circuit breakers can be installed in panels and switchboards in either the horizontal or vertical planes while being fed from either end without any derating of their performance characteristics • Interrupting ratings at 600VAC up to 100kAIC • Compact size • All Tmax molded case circuit breakers are CSA-UL listed and IEC rated for global application and acceptance ABB • All versions of the Tmax family are suitable for reverse feed applications The ABB Tmax series includes eight basic frame sizes as well as the T1 single pole with the range rated from 15A to 3000A at 600VAC. Frame Sizes — Eight Basic Sizes The ABB Tmax series includes eight basic frame sizes as well as the T1 single pole with the range rated from 15A to 3000A at 600VAC. The various versions carry the following interrupting capacities: • B Basic breaking capacity • N Normal breaking capacity • S Standard breaking capacity • H High breaking capacity • L Extra high breaking capacity • V Very high breaking capacity Derived Versions • • • • • Thermal magnetic Electronic Molded case switches Motor circuit protectors (MCPs) Direct current (DC) rated ABB Tmax Versions • Fixed: all models • Drawout or plug-in: T2, T3, Ts3, T4, T5, T6 and T7 • UL File #E93565 (breakers and MCPs) #E116596 (Accessories) #E116595 (Molded case switches) • CSA file #LR54280 1 AC1615S - 03/10 Selection Guide Circuit Breakers for Power Distribution T1 – Ts3 Tmax T1 1P T1 Type T3 Ts3 Tmax T1 1p Tmax T1 Tmax T2 Tmax T3 Tmax Ts3 [A] 100 100 100 225 150 225 [Nr] 1 3-4 3-4 3-4 2-3-4 2-3-4 AC (50-60Hz) [V] 347 600Y/347 480 600Y/347 600 480 DC [V] 500 600 500 Frame size Number of poles Rated voltage T2 Interrupting ratings 240V AC 500 B Tmax Ts3 N S H N S N H L N H L 50 (2) 65 100 50 65 65 100 150 65 100 150 35 65 25 50 85 (3) 25 50 65 14 14 25 500V DC (2 poles in series) [kA rms] 35 50 65 20 35 50 600V DC (3 poles in series) [kA rms] 20 35 50 [kA rms] 277V AC [kA rms] 18 (1) 347V AC [kA rms] 14 (1) 480V AC [kA rms] 22 (2) 25 35 600Y/347V AC [kA rms] 10 10 10 600V AC [kA rms] 250V DC (2 poles in series) [kA rms] 25 25 35 500V DC (3 poles in series) [kA rms] 25 25 35 Trip units TMF • • • • • • MA • • • • Electronic • TMD/TMA Dimensions H [in/mm] 5.12/130 5.12/130 5.12/130 5.9/150 6.7/170 6.7/170 W 3p [in/mm] 1/25.4 3/76 3.54/90 4.13/105 4.13/105 4.13/105 [in/mm] 2.76/70 2.76/70 2.76/70 2.76/70 4.07/103.5 4.07/103.5 25000 25000 25000 25000 25000 25000 D Mechanical life [No. operations] (1) In15A = 10kA@277VAC 10kA@347VAC (2) In15A = 35kA@240VAC 14kA@480Y/277 VAC (3) In from 15A up to 30A=65kA@480V AC 2 AC1615S - 03/10 ABB Selection Guide Circuit Breakers for Power Distribution T4 – T8 T4 T5 T6 Type Frame size T7 T8 Tmax T4 Tmax T5 Tmax T6 Tmax T7 [A] 250 400-600 (3) 800 1000-1200 [Nr] 2-3-4 (4) 2-3-4 (4) 3-4 3-4 AC (50-60Hz) [V] 600 600 600 600 DC [V] Number of poles Rated voltage Tmax Interrupting ratings 240V AC 600 N S H 600 L V N S H [kA rms] 347V AC [kA rms] 480V AC [kA rms] 25 600Y/347V AC [kA rms] 600V AC [kA rms] 18 1600, 2000, 2500 & 3000 3 600 600 L V N S H T8 L [kA rms] 65 100 150 200 200 65 100 150 200 200 65 100 200 200 277V AC Insulated Case T8 S H L T8V 65 100 150 125 35 65 100 150 25 35 65 100 150 35 50 65 100 50 65 100 125 25 35 65 100 18 25 35 25 35 42 25 50 65 100 500V DC (2 poles in series) [kA rms] 25 35 50 65 100 25 35 50 65 100 35 35 50 65 600V DC (3 poles in series) [kA rms] 16 25 35 50 25 35 50 20 35 50 65 100 20 250V DC (2 poles in series) [kA rms] 500V DC (3 poles in series) [kA rms] Trip units TMF • TMD/TMA • 65 16 • 65 20 • MA Electronic Dimensions • • • • • H [in/mm] 8.07/205 8.07/205 10.55/268 10.55/268 15 / 382 W 3p [in/mm] 4.13/105 5.51/140 8.26/210 16.8 / 427 [in/mm] 4.07/103.5 4.07/103.5 4.07/103.5 20,000 20,000 20,000 8.26/210 6.06/154 (toggle) 7/178 (motor) 10,000 D Mechanical life [No. operations] 11.2 / 282 15,000 (3) T5 600 with electronic trip units only and in three pole version(4) 2 pole T4N250 and T5N400 available only in N interrupting capacity. ABB 3 AC1615S - 03/10 General Information Catalog Number Explanation Tmax T3 S 080 T W - 4 xxx Accessories (Added In Alpha-Numeric Order) (1) A = Auxiliary Switch S_ = Shunt trip with voltage code U_ = Undervoltage release with voltage code Number Of Poles -1 = 1 pole (T1 only) -2 = 2 pole -4 = 4 pole None = 3 pole Type Connectors W= L = nals T = B = None Lugs on top/bottom termiLugs on top terminal Lugs on bottom terminal Trip Unit Function B D T M E5 C E P R S = = = = = = = = = = LS/I (AC only) Molded Case Switch (MCS) Thermal-magnetic Magnetic only (MCP) Electronic MCP (AC only) LSI (AC only) LSIG (AC only) PR332/P LI PR332/P LSI PR332/P LSIG Current Rating 015 080 100 225 250 400 600 800 1000 1200 = = = = = = = = = = 15A 80A 100A 225A 250A 400A 600A 800A 1000A 1200A 16 20 25 30 = = = = 1600A 2000A 2500A 3000A Interrupting Rating Class B N S H L V = = = = = = Basic Normal Standard High Extra High Very high Frame Size T1 = T2 = T3 = Ts3 = T4 = T5 = T6 = (2) T7 = 100A 100A 225A 225A 250A 400A, 600A 600A, 800A 1000A, 1200A (3) T8 = 1600A = 2000A = 2500A = 3000A (1) Consult ABB for factory installed accessories. (2) For T7, refer to page 40 (3) For T8, refer to page 46 4 AC1615S - 03/10 ABB T1 100A, 600Y/347VAC, 480VAC ∆ Thermal-Magnetic Dimensions Weight T1 3P Fixed Version 5.12H x 3.00W x 2.76D 2.34 (Ibs) T1 General UL489 / CSA C22.2 Interrupting Capacity (kA RMS) The T1 breaker family ranges from 15 through 100 amperes. The T1 trip units are non-interchangeable and use the very latest technology in electromagnetic relays for overcurrent trip protection. Thermal overload protection is provided by heat sensitive bimetals. Short-circuit protection for the breaker is accomplished using a precise magnetic coil. State of the art construction in contacts and arcing chambers aid in limiting damaging fault currents through the protected circuits. Voltage Continuous Rating B (1-Pole) N 240VAC 15 20 – 100 — — 35 50 277VAC 15 20 – 100 10 18 — — Standards 347VAC 15 20 – 100 10 14 — — 480Y/277VAC 15 — 14 480VAC 20 – 100 — 22 The UL489/CSA C22.2 No. 5 version of T1 also carries an IEC-60947-2 rating. Versions The T1 frame is available in two versions: T = Thermal-magnetic, fixed D = Molded case switch Performance Levels The T1 breaker has two performance levels available: B = Basic (Single Pole) N = Normal (3 or 4 pole) Number of Poles The UL/CSA version of the T1 is available in single, three and four pole versions. IEC versions of the T1 are also available with the same dimensions up to 160 amperes. Please contact ABB for details. Reverse Feeding All versions of the T1 family are suitable for reverse feed applications. Molded Case Switches UL/CSA switches include no overcurrent protection except for a high instantaneous trip mechanism for self protection. ABB 600Y/347VAC 15 – 100 — 10 250VDC 2 pole series 15 – 100A — 25 500VDC 3 pole series 15 – 100A — 25 IEC 60947-2 Interrupting Capacity (kA RMS) Voltage Continuous Rating B (1-Pole) N 230VAC 16 – 160A 25 50 415VAC 16 – 160A — 36 440VAC 16 - 160A — 22 500VAC 16 - 160A — 15 690VAC 16 – 160A — 6 250VDC 2 pole series 16 - 160A — 36 500VDC 2 pole series 16 – 160A — 36 5 AC1615S - 03/10 T1 600Y/347VAC, 480VAC ∆ Thermal-Magnetic/Molded Case Switch T1 T1-100A Frame, Thermal-Magnetic Trip Unit Fixed, 1 pole Breaker IC at 347VAC 10kA T1B 14kA Rating Magnetic Trip 1-Pole, 347VAC Part Number 15A 1000A T1B015TL-1 20A 25A 30A 40A 50A 60A 70A 80A 90A 100A 1000A 1000A 1000A 1000A 1500A 1500A 1500A 1500A 1500A 1500A T1B020TL-1 T1B025TL-1 T1B030TL-1 T1B040TL-1 T1B050TL-1 T1B060TL-1 T1B070TL-1 T1B080TL-1 T1B090TL-1 T1B100TL-1 List Price T1-100A Frame, Thermal-Magnetic Trip Unit Fixed Breaker IC at 480VAC 14kA T1N 22kA Rating Magnetic Trip 3-Pole, 600Y/347VAC/500VDC Part Number List Price 4-Pole, 600Y/347VAC/500VDC Part Number 15A 1000A T1N015TL T1N015TL-4 20A 25A 30A 40A 50A 60A 70A 80A 90A 100A 1000A 1000A 1000A 1000A 1500A 1500A 1500A 1500A 1500A 1500A T1N020TL T1N025TL T1N030TL T1N040TL T1N050TL T1N060TL T1N070TL T1N080TL T1N090TL T1N100TL T1N020TL-4 T1N025TL-4 T1N030TL-4 T1N040TL-4 T1N050TL-4 T1N060TL-4 T1N070TL-4 T1N080TL-4 T1N090TL-4 T1N100TL-4 List Price T-100A Frame,100% Rated Thermal-Magnetic Trip Unit Fixed Breaker IC at 480VAC 14kA T1NQ 22kA Rating 15 (1) 20 25 30 40 50 60 70 80 90 100 Magnetic Trip 3-Pole, 600Y/347VAC/500VDC Part Number 1000A 1000A 1000A 1000A 1000A 1500A 1500A 1500A 1500A 1500A 1500A T1NQ015TL T1NQ020TL T1NQ025TL T1NQ030TL T1NQ040TL T1NQ050TL T1NQ060TL T1NQ070TL T1NQ080TL T1NQ090TL T1NQ100TL Magnetic Trip 3-Pole, 600Y/347V/500VDC Part Number List Price T1-100A Frame, Molded Case Switch Breaker T1-D Interrupting Capacity (2) 240V, 50kA Rating 100A 1000A T1N100DL List Price 4-Pole, 600Y/347V/500VDC Part Number List Price TIN100DL-4 1 Rated 480Y/277VAC for 15A. 2 When protected by a OCPD with appropriate ratings. 6 AC1615S - 03/10 Discount Schedule DS-ST ABB T2 100A, 480VAC ∆ Thermal-Magnetic/Electronic/Current Limiting Dimensions Weight 3P Fixed Version 2.84 (Ibs) T2 5.12H x 3.54W x 2.76D T2 General The T2 breaker family ranges from 10 through 100 amperes. The T2 trip units are non-interchangeable and use the very latest technology in electromagnetic relays for overcurrent trip protection as well as a version with microprocessorbased electronic trip unit. Thermal overload protection is provided by heat sensitive bimetals. State of the art construction in contacts and arcing chambers aid in limiting damaging fault currents through the protected circuits. Standards The UL489/CSA C22.2 No. 5 version of T2 also carries an IEC-60947-2 rating. Versions The T2 frame is available in four versions: T = Thermal-magnetic, fixed B = Adjustable LS/I electronic M = Magnetic only (MCP) E5 = Electronic instantaneous only (MCP) Trip Functions These tripping functions are available: L = Long time S = Short time I = Instantaneous UL489 / CSA C22.2 Interrupting Capacity (kA RMS) Voltage Continuous Rating S H 240VAC 10 – 100A 65 150 480VAC ∆ 10 – 100A 35 65 IEC 60947-2 Interrupting Capacity (kA RMS) Voltage Continuous Rating S H 230VAC 1.6 – 160A 85 100 415VAC 1.6 – 160A 50 70 440V 1.6 – 160A 45 55 500V 1.6 – 160A 30 36 690VAC 1.6 – 160A 7 8 250VDC 2 pole series 1.6 – 160A 50 70 500VDC 3 pole series 1.6 – 160A 50 70 Perfomance Levels The T2 breaker has two performance levels available: S = Standard H = High - UL Current Limiting Number of Poles The UL/CSA version of the T2 is available in three and four pole versions. IEC versions of the T2 are also available with the same dimensions up to 160 amperes. Please contact ABB for details. Reverse Feeding All versions of the T2 family are suitable for reverse feed applications. ABB 7 AC1615S - 03/10 T2 100A, 480VAC ∆ Thermal-Magnetic/Current Limiting T2 T2-100A Frame, Thermal-Magnetic Trip Unit Fixed IC at 480VAC Rating Magnetic Trip T2S 35kA 15A 20A 25A 30A 40A 50A 60A 70A 80A 90A 100A 500A 500A 500A 500A 500A 500A 600A 700A 800A 900A 1000A T2S015TW T2S020TW T2S025TW T2S030TW T2S040TW T2S050TW T2S060TW T2S070TW T2S080TW T2S090TW T2S100TW Breaker IC at 480VAC Rating Magnetic Trip 3-Pole, 480VAC Part Number 65kA 15A 20A 25A 30A 40A 50A 60A 70A 80A 90A 100A 500A 500A 500A 500A 500A 500A 600A 700A 800A 900A 1000A T2H015TW T2H020TW T2H025TW T2H030TW T2H040TW T2H050TW T2H060TW T2H070TW T2H080TW T2H090TW T2H100TW Breaker T2H UL Current Limiting 3-Pole, 480VAC Part Number List Price 4-Pole, 480VAC Part Number List Price T2S015TW-4 T2S020TW-4 T2S025TW-4 T2S030TW-4 T2S040TW-4 T2S050TW-4 T2S060TW-4 T2S070TW-4 T2S080TW-4 T2S090TW-4 T2S100TW-4 List Price 4-Pole, 480VAC Part Number List Price T2H015TW-4 T2H020TW-4 T2H025TW-4 T2H030TW-4 T2H040TW-4 T2H050TW-4 T2H060TW-4 T2H070TW-4 T2H080TW-4 T2H090TW-4 T2H100TW-4 T2-100A Frame, 100% Rated Thermal-Magnetic Trip Unit Fixed IC at 480VAC Rating Magnetic Trip T2SQ 35kA 15A 20A 25A 30A 40A 50A 60A 70A 80A 90 A 100A 500A 500A 500A 500A 500A 500A 600A 700A 800A 900A 1000A Breaker IC at 480VAC Rating Magnetic Trip 3-Pole, 480VAC Part Number 65kA 15A 20A 25A 30A 40A 50A 60A 70A 80A 90A 100A 500A 500A 500A 500A 500A 500A 600A 700A 800A 900A 1000A T2HQ015TW T2HQ020TW T2HQ025TW T2HQ030TW T2HQ040TW T2HQ050TW T2HQ060TW T2HQ070TW T2HQ080TW T2HQ090TW T2HQ100TW Breaker T2HQ UL Current Limiting 8 AC1615S - 03/10 3-Pole, 480VAC Part Number List Price T2SQ015TW T2SQ020TW T2SQ025TW T2SQ030TW T2SQ040TW T2SQ050TW T2SQ060TW T2SQ070TW T2SQ080TW T2SQ090TW T2SQ100TW Discount Schedule DS-ST List Price ABB T2 100A, 480VAC ∆ Electronic/Current Limiting, 100% Rated, MCP T2 T2-100A Frame, Electronic Trip Unit (AC Only) Breaker IC at 480VAC T2S 35kA PR221DS-LS/I 25A 60A 100A T2S025BW T2S060BW T2S100BW T2S025BW-4 T2S060BW-4 T2S100BW-4 65kA PR221DS-LS/I 25A 60A 100A T2H025BW T2H060BW T2H100BW T2H025BW-4 T2H060BW-4 T2H100BW-4 T2H UL Current Limiting Trip Unit Type CT Rating 3-Pole, 480VAC Part Number List Price 4-Pole, 480VAC Part Number List Price T2-100A Frame, 100% Rated Electronic Trip Unit (AC Only) Breaker IC at 480VAC Trip Unit Type T2SQ 35kA PR221DS-LS/I T2HQ UL Current Limiting 65kA PR221DS-LS/I CT Rating 25A 60A 3-Pole, 480VAC Part Number List Price T2SQ025BW T2SQ060BW 100A T2SQ100BW 25A 60A T2HQ025BW T2HQ060BW 100A T2HQ100BW T2 -100A Frame, Motor Control Protection (MCP) Magnetic Only Trip Unit Breaker IC at 480VAC Trip Unit Type Rating Adjustment Range 3-Pole, 480VAC Part Number T2S 35kA Mag only 20A 50A 100A 120 - 240 300 - 600 600 – 1200 T2S020MW T2S050MW T2S100MW T2H 65kA Mag only 20A 50A 100A 120 - 240 300 - 600 600 – 1200 T2H020MW T2H050MW T2H100MW List Price T2 -100A Frame, Motor Control Protection (MCP) Magnetic Only Electronic Trip Unit (AC Only) ABB Breaker IC at 480VAC Trip Unit Type Rating Adjustment Range T2S 35kA Instantaneous only 25A 60A 100A 25 - 250 60 - 600 100 - 1000 T2S025E5W T2S060E5W T2S100E5W T2H 65kA Instantaneous only 25A 60A 100A 25 - 250 60 - 600 100 - 1000 T2H025E5W T2H060E5W T2H100E5W Discount Schedule DS-ST 3-Pole, 480VAC Part Number List Price 9 AC1615S - 03/10 T3 225A, 600Y/347VAC, 480VAC ∆ Thermal-Magnetic T3 Dimensions 3P Fixed Version 5.9H x 4.13W x 2.76D Weight 5.45 (Ibs) T3 General The T3 breaker family ranges from 60 through 225 amperes. The T3 trip units are non-interchangeable and use the very latest technology in electromagnetic relays for overcurrent trip protection. Thermal overload protection is provided by heat sensitive bimetals. Short-circuit protection begins at 10 times the thermal rating of the breaker using a precise magnetic coil. State of the art construction in contacts and arcing chambers aid in limiting damaging fault currents through the protected circuits. Standards UL489 / CSA C22.2 Interrupting Capacity (kA RMS) Voltage Continuous Rating N S 240VAC 60 – 225A 50 65 480VAC ∆ 60 – 225A 25 35 600Y/347VAC 60 – 225A 10 10 250VDC (1) 60 – 225A 25 35 500VDC (2) 60 – 225A 25 35 The UL489/CSA C22.2 No. 5 version of T3 also carries an IEC-60947-2 rating. Versions The T3 frame is available in three versions: T = Thermal-magnetic, fixed M = Magnetic only (MCP) D = Molded case switch Performance Levels The T3 breaker has two performance levels available: N = Normal S = Standard Number of Poles IEC 60947-2 Interrupting Capacity (kA RMS) Voltage Continuous Rating B (1-Pole) N 230VAC 63 – 250A 50 85 415VAC 63 – 250A 36 50 440V 63 – 250A 25 40 30 500V 63 – 250A 20 690VAC 63 – 250A 5 8 250VDC (1) 63 – 250A 36 50 500VDC (2) 63 – 250A 36 50 The UL/CSA version of the T3 is available in three and four pole versions. IEC versions of the T3 are also available with the same dimensions up to 250 amperes. Please contact ABB for details. Molded Case Switches UL/CSA switches include no overcurrent protection except for a high instantaneous trip mechanism for self protection. Reverse Feeding All versions of the T3 family are suitable for reverse feed application. (1) 2 poles in series. (2) 3 poles in series. 10 AC1615S - 03/10 ABB T3 225A, 600Y/347VAC, 480VAC ∆ Thermal-Magnetic T3 T3-225A Frame, Thermal-Magnetic Trip Unit Fixed Breaker IC at 480VAC T3N 25kA Breaker IC at 480VAC T3S 35kA Rating Magnetic Trip 3-Pole, 600Y/347VAC-500DC Part Number List Price 4-Pole, 600Y/347VAC-500DC Part Number 60A 600A T3N060TW T3N060TW-4 70A 80A 90A 100A 700A 800A 900A 1000A T3N070TW T3N080TW T3N090TW T3N100TW T3N070TW-4 T3N080TW-4 T3N090TW-4 T3N100TW-4 125A 150A 175A 200A 225A 1250A 1500A 1750A 2000A 2250A T3N125TW T3N150TW T3N175TW T3N200TW T3N225TW T3N125TW-4 T3N150TW-4 T3N175TW-4 T3N200TW-4 T3N225TW-4 Rating Magnetic Trip 3-Pole, 600Y/347VAC-500DC Part Number List Price 4-Pole, 600Y/347VAC-500DC Part Number 60A 600A T3S060TW T3S060TW-4 70A 80A 90A 100A 700A 800A 900A 1000A T3S070TW T3S080TW T3S090TW T3S100TW T3S070TW-4 T3S080TW-4 T3S090TW-4 T3S100TW-4 125A 150A 175A 200A 225A 1250A 1500A 1750A 2000A 2250A T3S125TW T3S150TW T3S175TW T3S200TW T3S225TW T3S125TW-4 T3S200TW-4 T3S175TW-4 T3S200TW-4 T3S225TW-4 List Price List Price T3-225A Frame, 100% Rated Thermal-Magnetic Trip Unit Fixed Breaker T3NQ 25kA Breaker IC at 480VAC T3SQ ABB IC at 480VAC 35kA Magnetic Trip 3-Pole, 600Y/347VAC-500VDC Part Number 60A 600A T3NQ060TW 70A 80A 90A 100A 700A 800A 900A 1000A T3NQ070TW T3NQ080TW T3NQ090TW T3NQ100TW 125A 150A 175A 200A 225A 1250A 1500A 1750A 2000A 2250A T3NQ125TW T3NQ150TW T3NQ175TW T3NQ200TW T3NQ225TW Magnetic Trip 3-Pole, 600Y/347VAC-500VDC Part Number 60A 600A T3SQ060TW 70A 80A 90A 100A 700A 800A 900A 1000A T3SQ070TW T3SQ080TW T3SQ090TW T3SQ100TW 125A 150A 175A 200A 225A 1250A 1500A 1750A 2000A 2250A T3SQ125TW T3SQ150TW T3SQ175TW T3SQ200TW T3SQ225TW Rating Rating Discount Schedule DS-ST List Price List Price 11 AC1615S - 03/10 T3 225A, 600Y/347VAC, 480VAC ∆ MCP/Molded Case Switch T3 T3-225A Frame, Motor Control Protection (MCP) Magnetic Only Trip Unit Breaker IC at 480VAC IC at 600Y/347VAC IC at 500VDC Trip Unit Type Rating T3S 35kA 10kA 35kA Mag only 100A 125A 150A 200A Adjustment Range 600 – 1200 750 - 1500 900 - 1800 1200 - 2400 3-Pole, 600Y/347VAC-500VDC Part Number List Price T3S100MW T3S125MW T3S150MW T3S200MW T3S-225A Frame, Molded Case Switch Breaker T3S-D 12 AC1615S - 03/10 Rating 150A 225A Magnetic Trip 1500A 2250A 3-Pole, 600Y/347VAC-500VDC Part Number T3S150DW T3S225DW Discount Schedule DS-ST List Price 4-Pole, 600Y/3 500VDC Part Number List Price T3S150DW-4 T3S225DW-4 ABB Ts3 150A 600VAC ∆ / 225A, 480VAC Thermal-Magnetic Dimensions 3P Fixed Version 6.7H x 4.13W x 4.07D Weight 6.75 (Ibs) Ts3 Ts3 General The Ts3 breaker family ranges from 15 through 225 amperes. The Ts3 trip mechanisms are non-interchangeable and use sensitive electromagnetic relays for overcurrent trip protection. Heat sensitive bimetals are used for thermal overcurrent protection. Short-circuit current protection begins at 10 times the thermal rating of the breaker and uses a magnetic coil principle. Standards The UL489/CSA C22.2 No. 5 version of Ts3 also carries an IEC-60947-2 rating. Versions To meet all application needs, the Ts3 is available in various versions: T = Thermal-magnetic D = Molded case switch M = Magnetic only (MCP) Performance Level Each version is also available in different maximum fault interrupting levels N = Normal H = High L = Extra high Number of Poles UL/CSA Interrupting Capacity (kA RMS) UL489 / CSA C22.2 Voltage N H L 240 VAC 480 VAC 600 VAC (2) 500 VDC (4) 600 VDC (5) Ts3/225A 500VDC (3) 65 25 14 35 20 20 100 50 14 50 35 35 150 85 (1) 25 65 50 50 IEC-60947-2 Interrupting Capacity (kA RMS) Voltage N H 230 VAC 380/400/415VAC 440 VAC 500 VAC 690 VAC 500 VDC 750 VDC 65 35 30 25 14 35 20 100 65 50 40 18 50 35 L 170 85 65 50 20 65 50 In UL/CSA form, the Ts3 is available in two pole or three pole versions, both with the same dimensions. A four-pole version is also available in the N version. For price estimation, add 35% to list price of selected version three pole breaker, contact ABB for details. Molded Case Switches UL/CSA switches include no overcurrent protection except for a high instantaneous trip mechanism for self protection. IEC type molded case switches with no trip protection are also available. Reverse Feeding All versions of the Ts3 family are suitable for reverse feed application. (1) 15-30A and 175-200-225A are 65kA at 480VAC (2) Ts3 175A, 200A, 225A are rated 480VAC / 500DVC maximum (3) Ts3 175A, 200A, 225A (4) 2 poles in series (5) 3 poles in series ABB 13 AC1615S - 03/10 Ts3 150A, 600VAC ∆ / 225A, 480VAC ∆ Thermal-Magnetic Ts3 Ts3-150A Frame, Thermal-Magnetic Trip Unit Fixed Breaker IC at 600VAC 14kA Ts3N IC at 480VAC 25kA Breaker IC at 600VAC 14kA Ts3H IC at 480VAC 50kA Breaker IC at 600VAC 25kA Ts3L IC at 480VAC 65kA Rating Magnetic Trip 2-Pole, 480VAC/500VDC Part Number 15A 20A 25A 30A 35A 40A 50A 60A 70A 80A 90A 100A 125A 150A 175A (1) 200A (1) 225A (1) 500A 500A 500A 500A 500A 500A 500A 600A 700A 800A 900A 1000A 1250A 1500A 1750A 2000A 2250A Ts3N015TW-2 Ts3N020TW-2 Ts3N025TW-2 Ts3N030TW-2 Ts3N035TW-2 Ts3N040TW-2 Ts3N050TW-2 Ts3N060TW-2 Ts3N070TW-2 Ts3N080TW-2 Ts3N090TW-2 Ts3N100TW-2 Ts3N125TW-2 Ts3N150TW-2 Ts3N175TW-2 Ts3N200TW-2 Ts3N225TW-2 Rating Magnetic Trip 2-Pole, 480VAC/500VDC Part Number 15A 20A 25A 30A 35A 40A 50A 60A 70A 80A 90A 100A 125A 150A 175A (1) 200A (1) 225A (1) 500A 500A 500A 500A 500A 500A 500A 600A 700A 800A 900A 1000A 1250A 1500A 1750A 2000A 2250A Ts3H015TW-2 Ts3H020TW-2 Ts3H025TW-2 Ts3H030TW-2 Ts3H035TW-2 Ts3H040TW-2 Ts3H050TW-2 Ts3H060TW-2 Ts3H070TW-2 Ts3H080TW-2 Ts3H090TW-2 Ts3H100TW-2 Ts3H125TW-2 Ts3H150TW-2 Ts3H175TW-2 Ts3H200TW-2 Ts3H225TW-2 Rating Magnetic Trip 2-Pole, 480VAC/500VDC Part Number 15A 20A 25A 30A 35A 40A 50A 60A 70A 80A 90A 100A 125A 150A 175A (1) 200A (1) 225A (1) 500A 500A 500A 500A 500A 500A 500A 600A 700A 800A 900A 1000A 1250A 1500A 1750A 2000A 2250A Ts3L015TW-2 Ts3L020TW-2 Ts3L025TW-2 Ts3L030TW-2 Ts3L035TW-2 Ts3L040TW-2 Ts3L050TW-2 Ts3L060TW-2 Ts3L070TW-2 Ts3L080TW-2 Ts3L090TW-2 Ts3L100TW-2 Ts3L125TW-2 Ts3L150TW-2 Ts3L175TW-2 Ts3L200TW-2 Ts3L225TW-2 List Price 3-Pole, 600VAC/600VDC Part Number List Price Ts3N015TW Ts3N020TW Ts3N025TW Ts3N030TW Ts3N035TW Ts3N040TW Ts3N050TW Ts3N060TW Ts3N070TW Ts3N080TW Ts3N090TW Ts3N100TW Ts3N125TW Ts3N150TW Ts3N175TW Ts3N200TW Ts3N225TW List Price 3-Pole, 600VAC/600VDC Part Number 4-Pole, 600VAC/600VDC Part Number List Price Ts3N015TW-4 Ts3N020TW-4 Ts3N025TW-4 Ts3N030TW-4 Ts3N035TW-4 Ts3N040TW-4 Ts3N050TW-4 Ts3N060TW-4 Ts3N070TW-4 Ts3N080TW-4 Ts3N090TW-4 Ts3N100TW-4 Ts3N125TW-4 Ts3N150TW-4 Ts3N175TW-4 Ts3N200TW-4 Ts3N225TW-4 List Price Ts3H015TW Ts3H020TW Ts3H025TW Ts3H030TW Ts3H035TW Ts3H040TW Ts3H050TW Ts3H060TW Ts3H070TW Ts3H080TW Ts3H090TW Ts3H100TW Ts3H125TW Ts3H150TW Ts3H175TW Ts3H200TW Ts3H225TW List Price 3-Pole, 600VAC/600VDC Part Number List Price Ts3L015TW Ts3L020TW Ts3L025TW Ts3L030TW Ts3L035TW Ts3L040TW Ts3L050TW Ts3L060TW Ts3L070TW Ts3L080TW Ts3L090TW Ts3L100TW Ts3L125TW Ts3L150TW Ts3L175TW Ts3L200TW Ts3L225TW (1) 480VAC/500VDC maximum 14 AC1615S - 03/10 Discount Schedule DS-ST ABB Ts3 150A, 600VAC ∆ / 225A, 480VAC ∆, 100% Rated Thermal-Magnetic Ts3 Ts3-225A Frame, 100% Rated Thermal-Magnetic Trip Units Breaker IC at 600VAC 14kA Ts3NQ IC at 480VAC 25kA Breaker IC at 600VAC 14kA Ts3HQ IC at 480VAC 50kA Breaker IC at 600VAC 25kA Ts3LQ IC at 480VAC 65kA Rating Magnetic Trip 3-Pole, 600VAC/600VDC Part Number 15A 20A 25A 30A 35A 40A 50A 60A 70A 80A 90A 100A 125A 150A 175A (1) 200A (1) 225A (1) 500A 500A 500A 500A 500A 500A 500A 600A 700A 800A 900A 1000A 1250A 1500A 1750A 2000A 2250A Ts3NQ015TW Ts3NQ020TW Ts3NQ025TW Ts3NQ030TW Ts3NQ035TW Ts3NQ040TW Ts3NQ050TW Ts3NQ060TW Ts3NQ070TW Ts3NQ080TW Ts3NQ090TW Ts3NQ100TW Ts3NQ125TW Ts3NQ150TW Ts3NQ175TW Ts3NQ200TW Ts3NQ225TW Rating Magnetic Trip 3-Pole, 600VAC/600VDC Part Number 15A 20A 25A 30A 35A 40A 50A 60A 70A 80A 90A 100A 125A 150A 175A (1) 200A (1) 225A (1) 500A 500A 500A 500A 500A 500A 500A 600A 700A 800A 900A 1000A 1250A 1500A 1750A 2000A 2250A Ts3HQ015TW Ts3HQ020TW Ts3HQ025TW Ts3HQ030TW Ts3HQ035TW Ts3HQ040TW Ts3HQ050TW Ts3HQ060TW Ts3HQ070TW Ts3HQ080TW Ts3HQ090TW Ts3HQ100TW Ts3HQ125TW Ts3HQ150TW Ts3HQ175TW Ts3HQ200TW Ts3HQ225TW Rating Magnetic Trip 3-Pole, 600VAC/600VDC Part Number 15A 20A 25A 30A 35A 40A 50A 60A 70A 80A 90A 100A 125A 150A 175A (1) 200A (1) 225A (1) 500A 500A 500A 500A 500A 500A 500A 600A 700A 800A 900A 1000A 1250A 1500A 1750A 2000A 2250A Ts3LQ015TW Ts3LQ020TW Ts3LQ025TW Ts3LQ030TW Ts3LQ035TW Ts3LQ040TW Ts3LQ050TW Ts3LQ060TW Ts3LQ070TW Ts3LQ080TW Ts3LQ090TW Ts3LQ100TW Ts3LQ125TW Ts3LQ150TW Ts3LQ175TW Ts3LQ200TW Ts3LQ225TW List Price List Price List Price (1) 480VAC/500VDC maximum ABB Discount Schedule DS-ST 15 AC1615S - 03/10 Ts3 150A, 600VAC ∆ / 225A, 450VAC, 480VAC MCP/Molded Case Switch Ts3 Ts3-225A Frame, Motor Control Protection (MCP) Magnetic Only Trip Unit Breaker IC at 480VAC IC at 600VAC IC at 500VDC IC at 600VDC 10kA 10kA 10kA 10kA 25kA 25kA 25kA 25kA - Ts3L 25kA 25kA 25kA 25kA 85kA 85kA 85kA 85kA 65kA 65kA 50kA 50kA 50kA 50kA 50kA 50kA 50kA 50kA 65kA 65kA 65kA 65kA 50kA 50kA 50kA - - Trip Unit Type Mag only Mag only Mag only Mag only Mag only Mag only Mag only Mag only Mag only Mag only Rating 3 5 10 25 50 100 125 150 175 (1) 200 (1) Adjustment Range 3-Pole, 600VAC/600VDC 12-36 20-60 40-120 100-300 200-600 400-1200 500-1500 600-1500 700-2100 800-2400 Ts3L003MW Ts3L005MW Ts3L010MW Ts3L025MW Ts3L050MW Ts3L100MW Ts3L125MW Ts3L150MW Ts3L175MW Ts3L200MW Part Number List Price Ts3-225A Frame, Molded Case Switch Type Voltage (max.) Magnetic Trip Ts3H 600VAC/600VDC 480VAC/500VDC 1500 2250 Amps 150 225 (1) 3-Pole 600VAC/600VDC Part Number Ts3H150DW Ts3H225DW List Price 4-Pole, 600VAC/600VDC Part Number List Price Ts3H150DW-4 Ts3H225DW-4 (1) 480VAC/500VDC Maximum 16 AC1615S - 03/10 Discount Schedule DS-ST ABB T4 250A, 600VAC ∆ Electronic and Thermal-Magnetic Dimensions 3P Fixed Version 8.07H x 4.13W x 4.07D Weight 6.18 (Ibs) T4 T4 General The T4 breaker is a 250 amp frame with either a microprocessor based over current protective trip system or a thermal magnetic trip unit. Standards The UL489/CSA C22.2 No. 5 version of T4 also carries an IEC-60947-2 rating. Versions To meet all application requirements, the T4 is available in the following versions: T = Thermal-magnetic B = Selectable & adjustable LI or LS C = Adjustable LSI E = Adjustable LSIG D = Molded Case Switch E5 = Electronic instantaneous only (MCP) Trip Functions These trip functions are available: L = Long time S = Short time I = Instantaneous G = Ground fault UL489 / CSA C22.2 Interrupting Capacity (kA RMS) Voltage Continuous Rating N S H L V 240VAC 20 - 250A 65 100 150 200 200 480VAC 20 - 250A 25 35 65 100 150 600VAC 20 - 250A 18 25 35 65 100 500VDC (1) 20 - 250A 25 35 50 65 100 (2) 20 - 250A 16 25 35 50 65 600VDC IEC 60947-2 Interrupting Capacity (kA RMS) Voltage Continuous Rating N S H L V 230VAC 20 - 320A 70 85 100 200 200 415VAC 20 - 320A 36 50 70 120 200 440VAC 20 - 320A 30 40 65 100 180 500VAC 20 - 320A 25 30 50 85 150 690VAC 20 - 320A 20 25 40 70 80 750VDC 20 - 320A 18 25 36 50 70 Performance Levels Each version is also available in different maximum fault interrupting levels: N = Normal S = Standard H = High - UL Current Limiting L = Extra high V = Very high - UL Current Limiting Number of Poles (3) The T4 is available as a 2, 3 and 4 pole breaker. The 2 and 3 pole versions have the same dimensions. Reverse Feeding All versions of the T4 family are suitable for reverse feed application. (1) 2 poles in series. (2) 3 poles in series. (3) 2 pole breakers available in N version only. 4 pole breakers available in N and H version only. ABB 17 AC1615S - 03/10 T4 250A, 600VAC ∆ Electronic (AC Only) T4 T4-100A Frame, Electronic Trip Unit (AC Only) 40-100A Adjustable Range Breaker IC at 600VAC T4N 18kA T4S 25kA T4H UL Current Limiting T4L T4V UL Current Limiting 35kA 65kA 100kA Trip Unit 2-Pole, 600VAC Part Number PR221 LS/I PR222 LSI PR222 LSIG PR221 LS/I PR222 LSI PR222 LSIG PR221 LS/I PR222 LSI PR222 LSIG PR221 LS/I PR222 LSI PR222 LSIG PR221 LS/I PR222 LSI PR222 LSIG T4N100BW-2 T4N100CW-2 T4N100EW-2 List Price 3-Pole, 600VAC Part Number List Price T4N100BW T4N100CW T4N100EW T4S100BW T4S100CW T4S100EW T4H100BW T4H100CW T4H100EW T4L100BW T4L100CW T4L100EW T4V100BW T4V100CW T4V100EW 4-Pole, 600VAC Part Number List Price T4N100BW-4 T4N100CW-4 T4N100EW-4 T4H100BW-4 T4H100CW-4 T4H100EW-4 T4-150A Frame, Electronic Trip Unit (AC Only) 60-150A Adjustable Range Breaker IC at 600VAC T4N 18kA T4S 25kA T4H UL Current Limiting T4L T4V UL Current Limiting T4V UL current limiting 35kA 65kA 100kA 100 Trip Unit 2-Pole, 600VAC Part Number PR221 LS/I PR222 LSI PR222 LSIG PR221 LS/I PR222 LSI PR222 LSIG PR221 LS/I PR222 LSI PR222 LSIG PR221 LS/I PR222 LSI PR222 LSIG PR221 LS/I PR222 LSI PR222 LSIG PR221 LS/I PR222 LSI PR222 LSIG T4N150BW-2 T4N150CW-2 T4N150EW-2 List Price 3-Pole, 600VAC Part Number List Price T4N150BW T4N150CW T4N150EW T4S150BW T4S150CW T4S150EW T4H150BW T4H150CW T4H150EW T4L150BW T4L150CW T4L150EW T4V150BW T4V150CW T4V150EW T4V150BW T4V150CW T4V150EW 4-Pole, 600VAC Part Number List Price T4N150BW-4 T4N150CW-4 T4N150EW-4 T4H150BW-4 T4H150CW-4 T4H150EW-4 T4-250A Frame, Electronic Trip Unit (AC Only) 100-250A Adjustable Range Breaker IC at 600VAC T4N 18kA T4S 25kA T4H UL Current Limiting T4L T4V UL Current Limiting 18 AC1615S - 03/10 35kA 65kA 100kA Trip Unit 2-Pole, 600VAC Part Number PR221 LS/I PR222 LSI PR222 LSIG PR221 LS/I PR222 LSI PR222 LSIG PR221 LS/I PR222 LSI PR222 LSIG PR221 LS/I PR222 LSI PR222 LSIG PR221 LS/I PR222 LSI PR222 LSIG T4N250BW-2 T4N250CW-2 T4N250EW-2 List Price Discount Schedule DS-ST 3-Pole, 600VAC Part Number T4N250BW T4N250CW T4N250EW T4S250BW T4S250CW T4S250EW T4H250BW T4H250CW T4H250EW T4L250BW T4L250CW T4L250EW T4V250BW T4V250CW T4V250EW List Price 4-Pole, 600VAC Part Number List Price T4N250BW-4 T4N250CW-4 T4N250EW-4 T4H250BW-4 T4H250CW-4 T4H250EW-4 ABB T4 250A, 600VAC ∆ Electronic 100% Rated (AC Only) Breaker IC at 600VAC T4NQ 18kA T4SQ 25kA T4HQ UL Current Limiting T4LQ T4VQ UL Current Limiting 35kA 65kA 100kA Trip Unit 3-Pole, 600VAC Part Number PR221 LS/I PR222 LSI PR222 LSIG PR221 LS/I PR222 LSI PR222 LSIG PR221 LS/I PR222 LSI PR222 LSIG PR221 LS/I PR222 LSI PR222 LSIG PR221 LS/I PR222 LSI PR222 LSIG T4NQ100BW T4NQ100CW T4NQ100EW T4SQ100BW T4SQ100CW T4SQ100EW T4HQ100BW T4HQ100CW T4HQ100EW T4LQ100BW T4LQ100CW T4LQ100EW T4VQ100BW T4VQ100CW T4VQ100EW T4-150A Frame, 100% Rated Electronic Trip Unit (AC Only) 60-150A Breaker IC at 600VAC T4NQ 18kA T4SQ 25kA T4HQ UL Current Limiting T4LQ T4VQ UL Current Limiting 35kA 65kA 100kA Trip Unit 3-Pole, 600V Part Number PR221 LS/I PR222 LSI PR222 LSIG PR221 LS/I PR222 LSI PR222 LSIG PR221 LS/I PR222 LSI PR222 LSIG PR221 LS/I PR222 LSI PR222 LSIG PR221 LS/I PR222 LSI PR222 LSIG T4NQ150BW T4NQ150CW T4NQ150EW T4SQ150BW T4SQ150CW T4SQ150EW T4HQ150BW T4HQ150CW T4HQ150EW T4LQ150BW T4LQ150CW T4LQ150EW T4VQ150BW T4VQ150CW T4VQ150EW List Price Adjustable Range T4-250A Frame, 100% Rated Electronic Trip Unit (AC Only) 100-250A Breaker IC at 600VAC T4NQ 18kA T4SQ 25kA T4HQ UL Current Limiting T4LQ T4VQ UL Current Limiting ABB 35kA 65kA 100kA Trip Unit 3-Pole, 600V Part Number PR221 LS/I PR222 LSI PR222 LSIG PR221 LS/I PR222 LSI PR222 LSIG PR221 LS/I PR222 LSI PR222 LSIG PR221 LS/I PR222 LSI PR222 LSIG PR221 LS/I PR222 LSI PR222 LSIG T4NQ250BW T4NQ250CW T4NQ250EW T4SQ250BW T4SQ250CW T4SQ250EW T4HQ250BW T4HQ250CW T4HQ250EW T4LQ250BW T4LQ250CW T4LQ250EW T4VQ250BW T4VQ250CW T4VQ250EW T4 List Price Adjustable Range List Price Discount Schedule DS-ST 19 AC1615S - 03/10 T4 250A, 600VAC ∆ Thermal-Magnetic Trip Units T4 T4-250A Frame, Thermal-Magnetic Trip Unit Breaker IC at 600VAC T4N 18kA T4S 25kA T4H UL Current Limiting T4L T4V UL Current Limiting Breaker T4N 20 AC1615S - 03/10 35kA 65kA 100kA Rating Magnetic Trip 3-Pole, 600VAC/600VDC Part Number 20A 30A (21-30A) 40A (28-40A) 50A (35-50A) 80A (56-80A) 100A (70-100A) 125A (88-125A) 150A (105-150A) 200A (140-200A) 250A (175-250A) 20A 30A (21-30A) 40A (28-40A) 50A (35-50A) 80A (56-80A) 100A (70-100A) 125A (88-125A) 150A (105-150A) 200A (140-200A) 250A (175-250A) 20A 30A (21-30A) 40A (28-40A) 50A (35-50A) 80A (56-80A) 100A (70-100A) 125A (88-125A) 150A (105-150A) 200A (140-200A) 250A (175-250A) 20A 30A (21-30A) 40A (28-40A) 50A (35-50A) 80A (56-80A) 100A (70-100A) 125A (88-125A) 150A (105-150A) 200A (140-200A) 250A (175-250A) 20A 30A (21-30A) 40A (28-40A) 50A (35-50A) 80A (56-80A) 100A (70-100A) 125A (88-125A) 150A (105-150A) 200A (140-200A) 250A (175-250A) 500 500 500 500 400-800 500-1000 625-1250 750-1500 1000-2000 1250-2500 500 500 500 500 400-800 500-1000 625-1250 750-1500 1000-2000 1250-2500 500 500 500 500 400-800 500-1000 625-1250 750-1500 1000-2000 1250-2500 500 500 500 500 400-800 500-1000 625-1250 750-1500 1000-2000 1250-2500 500 500 500 500 400-800 500-1000 625-1250 750-1500 1000-2000 1250-2500 T4N020TW T4N030TW T4N040TW T4N050TW T4N080TW T4N100TW T4N125TW T4N150TW T4N200TW T4N250TW T4S020TW T4S030TW T4S040TW T4S050TW T4S080TW T4S100TW T4S125TW T4S150TW T4S200TW T4S250TW T4H020TW T4H030TW T4H040TW T4H050TW T4H080TW T4H100TW T4H125TW T4H150TW T4H200TW T4H250TW T4L020TW T4L030TW T4L040TW T4L050TW T4L080TW T4L100TW T4L125TW T4L150TW T4L200TW T4L250TW T4V020TW T4V030TW T4V040TW T4V050TW T4V080TW T4V100TW T4V125TW T4V150TW T4V200TW T4V250TW Magnetic Trip 500 500 500 400-800 500-1000 625-1250 750-1500 1000-2000 1250-2500 2-Pole, 600VAC/500VDC Part Number T4N030TW-2 T4N040TW-2 T4N050TW-2 T4N080TW-2 T4N100TW-2 T4N125TW-2 T4N150TW-2 T4N200TW-2 T4N250TW-2 IC at 600VAC Rating 18kA 30A (21-30A) 40A (28-40A) 50A (35-50A) 80A (56-80A) 100A (70-100A) 125A (88-125A) 150A (100-150A) 200A (140-200A) 250A (175-250A) Discount Schedule DS-ST List Price 4-Pole, 600VAC/600VDC Part Number List Price T4N020TW-4 T4N030TW-4 T4N040TW-4 T4N050TW-4 T4N080TW-4 T4N100TW-4 T4N125TW-4 T4N150TW-4 T4N200TW-4 T4N250TW-4 T4H020TW-4 T4H030TW-4 T4H040TW-4 T4H050TW-4 T4H080TW-4 T4H100TW-4 T4H125TW-4 T4H150TW-4 T4H200TW-4 T4H250TW-4 List Price ABB T4 250A, 600VAC 100% Rated Thermal-Magnetic Trip Units T4 T4-250A Frame, 100% Rated Thermal-Magnetic Trip Unit Breaker ABB IC at 600VAC T4NQ 18kA T4SQ 25kA T4HQ 35kA T4LQ 65kA T4VQ 100kA Rating Magnetic Trip 3-Pole, 600VAC/600VDC Part Number 20A 30A (21-30A) 40A (28-40A) 50A (35-50A) 80A (56-80A) 100A (70-100A) 125A (88-125A) 150A (105-150A) 200A (140-200A) 250A (175-250A) 20A 30A (21-30A) 40A (28-40A) 50A (35-50A) 80A (56-80A) 100A (70-100A) 125A (88-125A) 150A (105-150A) 200A (140-200A) 250A (175-250A) 20A 30A (21-30A) 40A (28-40A) 50A (35-50A) 80A (56-80A) 100A (70-100A) 125A (88-125A) 150A (105-150A) 200A (140-200A) 250A (175-250A) 20A 30A (21-30A) 40A (28-40A) 50A (35-50A) 80A (56-80A) 100A (70-100A) 125A (88-125A) 150A (105-150A) 200A (140-200A) 250A (175-250A) 20A 30A (21-30A) 40A (28-40A) 50A (35-50A) 80A (56-80A) 100A (70-100A) 125A (88-125A) 150A (105-150A) 200A (140-200A) 250A (175-250A) 500 500 500 500 400-800 500-1000 625-1250 750-1500 1000-2000 1250-2500 500 500 500 500 400-800 500-1000 625-1250 750-1500 1000-2000 1250-2500 500 500 500 500 400-800 500-1000 625-1250 750-1500 1000-2000 1250-2500 500 500 500 500 400-800 500-1000 625-1250 750-1500 1000-2000 1250-2500 500 500 500 500 400-800 500-1000 625-1250 750-1500 1000-2000 1250-2500 T4NQ020TW T4NQ030TW T4NQ040TW T4NQ050TW T4NQ080TW T4NQ100TW T4NQ125TW T4NQ150TW T4NQ200TW T4NQ250TW T4SQ020TW T4SQ030TW T4SQ040TW T4SQ050TW T4SQ080TW T4SQ100TW T4SQ125TW T4SQ150TW T4SQ200TW T4SQ250TW T4HQ020TW T4HQ030TW T4HQ040TW T4HQ050TW T4HQ080TW T4HQ100TW T4HQ125TW T4HQ150TW T4HQ200TW T4HQ250TW T4LQ020TW T4LQ030TW T4LQ040TW T4LQ050TW T4LQ080TW T4LQ100TW T4LQ125TW T4LQ150TW T4LQ200TW T4LQ250TW T4VQ020TW T4VQ030TW T4VQ040TW T4VQ050TW T4VQ080TW T4VQ100TW T4VQ125TW T4VQ150TW T4VQ200TW T4VQ250TW Discount Schedule DS-ST List Price 21 AC1615S - 03/10 T4 250A, 600VAC ∆ MCP (Instantaneous Only), Molded Case Switch T4 T4-250A Frame, Motor Control Protection (MCP) Electronic Trip Unit (AC Only) Breaker IC at 600VAC Trip Unit Type Rating Adjustment Range 3-Pole, 600VAC Part Number T4N 18kA PR221 DS-I 100A 150A 250A 100A 150A 250A 100-1000 150-1500 250-2500 100-1000 150-1500 250-2500 T4N100E5W T4N150E5W T4N250E5W T4S100E5W T4S150E5W T4S250E5W T4S 25kA PR221 DS-I T4H 35kA PR221 DS-I 100A 150A 250A 100-1000 150-1500 250-2500 T4H100E5W T4H150E5W T4H250E5W T4L 65kA PR221 DS-I 100A 150A 250A 100-1000 150-1500 250-2500 T4L100E5W T4L150E5W T4L250E5W List Price T4-250A Frame, Molded Case Switch Type Amps Magnetic Trip 3-Pole, 600VAC/600VDC Part Number T4N-D T4S-D T4H-D T4L-D T4V-D 250 250 250 250 250 3000 3000 3000 3000 3000 T4N250DW T4S250DW T4H250DW T4L250DW T4V250DW 22 AC1615S - 03/10 Discount Schedule DS-ST List Price 4-Pole, 600VAC/600VDC Part Number List Price T4H250DW-4 ABB T5 400A / 600A, 600VAC ∆ Electronic and Thermal-Magnetic T5 Dimensions 3P Fixed Version 8.07H x 5.51W x 4.07D Weight 8.55 (Ibs) T5 General The T5 breaker is a 400/600 amp frame with either a microprocessor based over current protective trip system or a thermal magnetic trip unit. (3) UL489 / CSA C22.2 Interrupting Capacity (kA RMS) Voltage N S H L V 240VAC 65 100 150 200 200 480VAC 25 35 65 100 150 600VAC 18 25 35 65 100 Versions 500VDC (1) 25 35 50 65 100 To meet all application requirements, the T5 is available in the following versions: T = Thermal-magnetic B = Selectable & adjustable LI or LS C = Adjustable LSI E = Adjustable LSIG D = Molded Case Switch E5 = Electronic instantaneous only (MCP) 600VDC (2) 16 25 35 50 65 Standards The UL489/CSA C22.2 No. 5 version of T5 also carries an IEC-60947-2 rating. Trip Functions These trip functions are available: L = Long time S = Short time I = Instantaneous G = Ground fault Performance Levels IEC 60947-2 Interrupting Capacity (kA RMS) Voltage N S H L V 230VAC 70 85 100 200 200 415VAC 36 50 70 120 200 440VAC 30 40 65 100 180 500VAC 25 30 50 85 150 690VAC 20 25 40 70 80 16 25 36 50 70 750VDC (2) Each version is also available in different maximum fault interrupting levels: N = Normal S = Standard H = High L = Extra high V = Very high Number of Poles (4) The T5 is available as a 2, 3 and 4 pole breaker. The 2 and 3 pole versions have the same dimensions. Reverse Feeding All versions of the T5 family are suitable for reverse feed application. (1) 2 poles in series. (2) 3 poles in series. (3) T5 600A not available with thermal magnetic trip unit. (4) 2 pole available in N version only. 4 pole available in N and H version only. ABB 23 AC1615S - 03/10 T5 400A / 600A Electronic (AC Only) T5 T5-300A Frame, Electronic Trip Unit (AC Only) 120-300A Adjustable Range Breaker IC at 600VAC T5N 18kA T5S 25kA T5H 35kA T5L 65kA T5V 100kA Trip Unit 2-Pole, 600VAC Part Number PR221 LS/I PR222 LSI PR222 LSIG PR221 LS/I PR222 LSI PR222 LSIG PR221 LS/I PR222 LSI PR222 LSIG PR221 LS/I PR222 LSI PR222 LSIG PR221 LS/I PR222 LSI PR222 LSIG T5N300BW-2 T5N300CW-2 T5N300EW-2 List Price 3-Pole, 600VAC Part Number List Price T5N300BW T5N300CW T5N300EW T5S300BW T5S300CW T5S300EW T5H300BW T5H300CW T5H300EW T5L300BW T5L300CW T5L300EW T5V300BW T5V300CW T5V300EW 4-Pole, 600VAC Part Number List Price T5N300BW-4 T5N300CW-4 T5N300EW-4 T5H300BW-4 T5H300CW-4 T5H300EW-4 T5-400A Frame, Electronic Trip Unit (AC Only) 160-400A Adjustable Range Breaker IC at 600VAC T5N 18kA T5S 25kA T5H 35kA T5L 65kA T5V 100kA Trip Unit 2-Pole, 600VAC Part Number PR221 LS/I PR222 LSI PR222 LSIG PR221 LS/I PR222 LSI PR222 LSIG PR221 LS/I PR222 LSI PR222 LSIG PR221 LS/I PR222 LSI PR222 LSIG PR221 LS/I PR222 LSI PR222 LSIG T5N400BW-2 T5N400CW-2 T5N400EW-2 List Price 3-Pole, 600VAC Part Number T5N400BW T5N400CW T5N400EW T5S400BW T5S400CW T5S400EW T5H400BW T5H400CW T5H400EW T5L400BW T5L400CW T5L400EW T5V400BW T5V400CW T5V400EW List Price 4-Pole, 600VAC Part Number List Price T5N400BW-4 T5N400CW-4 T5N400EW-4 T5H400BW-4 T5H400CW-4 T5H400EW-4 T5-600A Frame, Electronic Trip Unit (AC Only) 240-600A Adjustable Range Breaker IC at 600VAC T5N 18kA T5S 25kA T5H 35kA T5L 65kA T5V 100kA 24 AC1615S - 03/10 Trip Unit 3-Pole, 600VAC Part Number PR221 LS/I PR222 LSI PR222 LSIG PR221 LS/I PR222 LSI PR222 LSIG PR221 LS/I PR222 LSI PR222 LSIG PR221 LS/I PR222 LSI PR222 LSIG PR221 LS/I PR222 LSI PR222 LSIG T5N600BW T5N600CW T5N600EW T5S600BW T5S600CW T5S600EW T5H600BW T5H600CW T5H600EW T5L600BW T5L600CW T5L600EW T5V600BW T5V600CW T5V600EW List Price Discount Schedule DS-ST ABB T5 400A 100% Rated Electronic (AC only) (1) T5 T5-300A Frame, 100% Rated Electronic Trip Units (AC Only) 120-300A Adjustable Range Breaker IC at 600VAC T5N 18kA T5S 25kA T5H 35kA T5L 65kA T5V 100kA Trip Unit PR221 LS/I PR222 LSI PR222 LSIG PR221 LS/I PR222 LSI PR222 LSIG PR221 LS/I PR222 LSI PR222 LSIG PR221 LS/I PR222 LSI PR222 LSIG PR221 LS/I PR222 LSI PR222 LSIG 3-Pole, 600VAC Part Number List Price T5NQ300BW T5NQ300CW T5NQ300EW T5SQ300BW T5SQ300CW T5SQ300EW T5HQ300BW T5HQ300CW T5HQ300EW T5LQ300BW T5LQ300CW T5LQ300EW T5VQ300BW T5VQ300CW T5VQ300EW T5-400A Frame, 100% Rated Electronic Trip Units (AC Only) 160-400A Adjustable Range Breaker IC at 600VAC T5N 18kA T5S 25kA T5H 35kA T5L 65kA T5V 100kA Trip Unit PR221 LS/I PR222 LSI PR222 LSIG PR221 LS/I PR222 LSI PR222 LSIG PR221 LS/I PR222 LSI PR222 LSIG PR221 LS/I PR222 LSI PR222 LSIG PR221 LS/I PR222 LSI PR222 LSIG 3-Pole, 600VAC Part Number List Price T5NQ400BW T5NQ400CW T5NQ400EW T5SQ400BW T5SQ400CW T5SQ400EW T5HQ400BW T5HQ400CW T5HQ400EW T5LQ400BW T5LQ400CW T5LQ400EW T5VQ400BW T5VQ400CW T5VQ400EW (1) T5 600A not available as 100% rated ABB Discount Schedule DS-ST 25 AC1615S - 03/10 T5 400A, 600VAC ∆ Thermal-Magnetic (1) T5 T5-300/400A Frame, Thermal-Magnetic Trip Unit Breaker IC at 600VAC T5N 18kA T5S 25kA T5H 35kA T5L 65kA T5V 100kA Rating Magnetic Trip 2-Pole, 600VAC/500VDC Part Number 300A 400A 300A 400A 300A 400A 300A 400A 300A 400A 1500-3000 2000-4000 1500-3000 2000-4000 1500-3000 2000-4000 1500-3000 2000-4000 1500-3000 2000-4000 T5N300TW-2 T5N400TW-2 List Price 3-Pole, 600VAC/600VDC Part Number T5N300TW T5N400TW T5S300TW T5S400TW T5H300TW T5H400TW T5L300TW T5L400TW T5V300TW T5V400TW List Price 4-Pole, 600VAC/600VDC Part Number List Price T5N300TW-4 T5N400TW-4 T5S300TW-4 T5S400TW-4 T5H300TW-4 T5H400TW-4 T5L300TW-4 T5L400TW-4 T5V300TW-4 T5V400TW-4 T5-300/400A Frames, 100% Rated, Thermal-Magnetic Trip Unit Breaker IC at 600VAC T5N 18kA T5S 25kA T5H 35kA T5L 65kA T5V 100kA Rating Magnetic Trip 3-Pole, 600VAC/500VDC Part Number 300A 400A 300A 400A 300A 400A 300A 400A 300A 400A 1500-3000 2000-4000 1500-3000 2000-4000 1500-3000 2000-4000 1500-3000 2000-4000 1500-3000 2000-4000 T5NQ300TW T5NQ400TW T5SQ300TW T5SQ400TW T5HQ300TW T5HQ400TW T5LQ300TW T5LQ400TW T5VQ300TW T5VQ400TW List Price (1) T5 600A not available with thermal-magnetic trip unit. 26 AC1615S - 03/10 Discount Schedule DS-ST ABB T5 400A / 600A MCP (Instantaneous Only), Molded Case Switch T5 T5-300/400A Frame, Motor Control Protection (MCP) Electronic Trip Unit (Ac Only) Breaker IC at 600VAC Trip Unit Rating Adjustment Range 3-Pole, 600VAC/600VDC Part Number T5N 18kA PR221DS-I 300A 400A 300A 400A 300-3000 400-4000 300-3000 400-4000 T5N300E5W T5N400E5W T5S 25kA PR221DS-I T5H 55kA PR221DS-I 300A 400A 300-3000 400-4000 T5H300E5W T5H400E5W T5L 65kA PR221DS-I 300A 400A 300-3000 400-4000 T5L300E5W T5L400E5W List Price T5S300E5W T5S400E5W T5-600A Frame, Motor Control Protection (MCP) Electronic Trip Unit (AC Only) Breaker IC at 600VAC Trip Unit Rating Adjustment Range 3-Pole, 600VAC/600VDC Part Number T5N 18kA PR221DS-I 25kA PR221DS-I 600A 600A 600-6000 600-6000 T5N600E5W T5S T5H 55kA PR221DS-I 600A 600-6000 T5H600E5W T5L 65kA PR221DS-I 600A 600-6000 T5L600E5W List Price T5S600E5W T5-400/600A Frame, Molded Case Switch ABB Type IC at 600VAC Amps Magnetic Trip 3-Pole, 600VAC/600VDC Part Number T5N-D T5S-D T5H-D T5L-D T5V-D T5N-D T5S-D T5H-D T5L-D T5V-D 18kA 25kA 35kA 65kA 100kA 18kA 25kA 35kA 65kA 100kA 400 400 400 400 400 600 600 600 600 600 5000 5000 5000 5000 5000 6000 6000 6000 6000 6000 T5N400DW T5S400DW T5H400DW T5L400DW T5V400DW T5N600DW T5S600DW T5H600DW T5L600DW T5V600DW Discount Schedule DS-ST List Price 4-Pole, 600VAC/600VDC Part Number List Price T5H400DW-4 27 AC1615S - 03/10 T6 600A / 800A, 600VAC ∆ Electronic & Thermal-Magnetic T6 Dimensions 4.07D 3P Fixed Version 10.55H x 8.26W x Weight 20.9 (Ibs) T6 General The T6 breaker is an 800 amp frame with either a microprocessor based over current protective trip system or a thermal magnetic trip unit. The T6 is available as a 600 or 800A frame. UL489 / CSA C22.2 Interrupting Capacity (kA RMS) Voltage N S H L 240VAC 65 100 200 200 480VAC 35 50 65 100 600VAC 20 25 35 42 Versions 500VDC (1) 35 35 50 65 To meet all application requirements, the T6 is available in the following versions: T = Thermal-magnetic, fixed B = Selectable & adjustable LI or LS C = Adjustable LSI E = Adjustable LSIG D = Molded Case Switch E5 = Electronic instantaneous only (MCP) 600VDC (2) 20 20 35 50 Standards The UL489/CSA C22.2 No. 5 version of T6 also carries an IEC-60947-2 rating. IEC 60947-2 Interrupting Capacity (kA RMS) Voltage N S H L 230VAC 70 85 100 200 Trip Functions 415VAC 36 50 70 100 These trip functions are available: L = Long time S = Short time I = Instantaneous G = Ground fault 600VAC 20 22 25 30 16 20 36 50 750VDC (2) Performance Levels Each version is also available in different maximum fault interrupting levels: N = Normal S = Standard H = High L = Extra high Number of Poles (3) The T6 is available as a 3 and 4 pole breaker. 4 poles only available in N or H version. Reverse Feeding All versions of the T6 family are suitable for reverse feed application. (1) 2 poles in series. (2) 3 poles in series. (3) 4 pole available N and H version only. 28 AC1615S - 03/10 ABB T6 600A / 800A, 600VAC ∆ Electronic (AC Only) T6 T6-600A Frame, Electronic Trip Unit (AC Only) 240-600A Adjustable Range Breaker IC at 600VAC T6N 20kA T6S 25kA T6H 35kA T6L 42kA Trip Unit 3-Pole, 600VAC Part Number PR221 LS/I PR222 LSI PR222 LSIG PR221 LS/I PR222 LSI PR222 LSIG PR221 LS/I PR222 LSI PR222 LSIG PR221 LS/I PR222 LSI PR222 LSIG T6N600BW T6N600CW T6N600EW T6S600BW T6S600CW T6S600EW T6H600BW T6H600CW T6H600EW T6L600BW T6L600CW T6L600EW List Price 4-Pole, 600VAC Part Number List Price T6N600BW-4 T6N600CW-4 T6N600EW-4 T6H600BW-4 T6H600CW-4 T6H600EW-4 T6-800A Frame, Electronic Trip Unit (AC Only) 320-800A Adjustable Range Breaker IC at 600VAC T6N 20kA T6S 25kA T6H 35kA T6L 42kA Trip Unit 3-Pole, 600VAC Part Number PR221 LS/I PR222 LSI PR222 LSIG PR221 LS/I PR222 LSI PR222 LSIG PR221 LS/I PR222 LSI PR222 LSIG PR221 LS/I PR222 LSI PR222 LSIG T6N800BW T6N800CW T6N800EW T6S800BW T6S800CW T6S800EW T6H800BW T6H800CW T6H800EW T6L800BW T6L800CW T6L800EW List Price 4-Pole, 600VAC Part Number List Price T6N800BW-4 T6N800CW-4 T6N800EW-4 T6H800BW-4 T6H800CW-4 T6H800EW-4 T6-600A Frame, 100% Rated Electronic Trip Unit (AC Only) 240-600A Adjustable Range Breaker IC at 600VAC T6N 20kA T6S 25kA T6H 35kA T6L 42kA Trip Unit 3-Pole, 600VAC Part Number PR221 LS/I PR222 LSI PR222 LSIG PR221 LS/I PR222 LSI PR222 LSIG PR221 LS/I PR222 LSI PR222 LSIG PR221 LS/I PR222 LSI PR222 LSIG T6NQ600BW T6NQ600CW T6NQ600EW T6SQ600BW T6SQ600CW T6SQ600EW T6HQ600BW T6HQ600CW T6HQ600EW T6LQ600BW T6LQ600CW T6LQ600EW List Price T6-800A Frame, 100% Rated Electronic Trip Unit (AC Only) 320-800A Adjustable Range Breaker IC at 600VAC T6N 20kA T6S 25kA T6H 35kA T6L 42kA ABB Trip Unit 3-Pole, 600VAC Part Number PR221 LS/I PR222 LSI PR222 LSIG PR221 LS/I PR222 LS/I PR222 LSIG PR221 LS/I PR222 LSI PR222 LSIG PR221 LS/I PR222 LSI PR222 LSIG T6NQ800BW T6NQ800CW T6NQ800EW T6SQ800BW T6SQ800CW T6SQ800EW T6HQ800BW T6HQ800CW T6HQ800EW T6LQ800BW T6LQ800CW T6LQ800EW List Price Discount Schedule DS-ST 29 AC1615S - 03/10 T6 600A / 800A, 600VAC ∆ Electronic & Thermal-Magnetic T6 T6-600/800A Frame, Thermal-Magnetic Trip Unit Breaker IC at 600VAC T6N 20kA T6S 25kA T6H 35kA T6L 42kA Rating Magnetic Trip 3-Pole, 600VAC/600VDC Part Number 600A 800A 600A 800A 600A 800A 600A 800A 3000 - 6000A 4000 - 8000A 3000 - 6000A 4000 - 8000A 3000 - 6000A 4000 - 8000A 3000 - 6000A 4000 - 8000A T6N600TW T6N800TW T6S600TW T6S800TW T6H600TW T6H800TW T6L600TW T6L800TW List Price 4-Pole, 600VAC/600VDC Part Number List Price T6N600TW-4 T6N800TW-4 T6H600TW-4 T6H800TW-4 T6-600/800A Frame, 100% Rated Thermal-Magnetic Trip Unit Breaker IC at 600VAC T6N 20kA T6S 25kA T6H 35kA T6L 42kA Rating Magnetic Trip 3-Pole, 600VAC/600VDC Part Number 600A 800A 600A 800A 600A 800A 600A 800A 3000 - 6000A 4000 - 8000A 3000 - 6000A 4000 - 8000A 3000 - 6000A 4000 - 8000A 3000 - 6000A 4000 - 8000A T6NQ600TW T6NQ800TW T6SQ600TW T6SQ800TW T6HQ600TW T6HQ800TW T6LQ600TW T6LQ800TW List Price T6-600A Frame, Motor Control Protection (MCP) Electronic Trip Unit (AC Only) Breaker IC at 600VAC Trip Unit Adjustment Range 3-Pole, 600VAC Part Number T6N T6S T6H T6L 20kA 25kA 35kA 42kA PR221 DS-I PR221 DS-I PR221 DS-I PR221 DS-I 600-6000 600-6000 600-6000 600-6000 T6N600E5W T6S600E5W T6H600E5W T6L600E5W List Price T6-800A Frame, Motor Control Protection (MCP) Electronic Trip Unit (AC Only) Breaker IC at 600VAC Trip Unit Adjustment Range 3-Pole, 600VAC Part Number T6N T6S T6H T6L 20kA 25kA 35kA 42kA PR221 DS-I PR221 DS-I PR221 DS-I PR221 DS-I 800-8000 800-8000 800-8000 800-8000 T6N800E5W T6S800E5W T6H800E5W T6L800E5W List Price T6-800A Frame, Molded Case Switch Breaker IC at 600VAC Amp Magnetic Trip 3-Pole, 600VAC/600VDC Part Number T6H 35kA 800 10,000 T6H800DW 30 AC1615S - 03/10 List Price Discount Schedule DS-ST 4-Pole, 600VAC/600VDC Part Number List Price T6H800DW-4 ABB T7-T7M 1000A / 1200A, 600VAC ∆ Electronic (AC Only) T7 Dimensions 3P Fixed Version 10.55H x 8.26W x 6.07D (1) Weight 21.4 (Ibs) T7 General The T7 breaker is a 1200 amp frame with a microprocessor based over current protective trip system. Available in 2 versions: T7 for toggle operated, T7M for motor operated Standards The UL489/CSA C22.2 No. 5 version of T7 also carries an IEC-60947-2 rating. UL489 / CSA C22.2 Interrupting Capacity (kA RMS) Voltage S H L 240VAC 65 100 150 480VAC 50 65 100 600VAC 25 50 65 Versions To meet all application requirements, the T7 is available in the following versions: B = PR231-LS/I adjustable (dip switch) C = PR232-LSI adjustable (dip switch) E = PR331-LSIG adjustable (dip switch) D = Moulded Case Switch P = PR332-LI adjustable (keypad + LCD display) R = PR332-LSI adjustable (keypad + LCD display) S = PR332-LSIG adjustable (keypad + LCD display) IEC 60947-2 Interrupting Capacity (kA RMS) Voltage S H L 230VAC 85 100 200 415VAC 50 70 120 690VAC 30 42 50 Trip Functions These trip functions are available: L = Long time S = Short time I = Instantaneous G = Ground fault Performance Levels Each version is also available in different maximum fault interrupting levels: S = Standard H = High L = Extra high Number of Poles The T7 is available as a 3 and 4 pole breaker. (1) Toggle type (dimensions of toggle not included) ABB 31 AC1615S - 03/10 T7 1000A / 1200A, 600VAC ∆ Electronic (AC Only) T7 T7S-1000A Frame, Electronic Trip Unit (AC Only) Breaker T7S IC at 600VAC Trip Unit 25kA PR231/P PR232/P PR331/P PR332/P PR332/P PR332/P Adjustment 3-Pole, 600VAC Part Number LS/I LSI LSIG LI LSI LSIG T7S1000BW T7S1000CW T7S1000EW T7S1000PW T7S1000RW T7S1000SW List Price 4-Pole, 600VAC Part Number List Price T7S1000BW-4 T7S1000CW-4 T7S1000EW-4 T7S1000PW-4 T7S1000RW-4 T7S1000SW-4 T7S-1200A Frame, Electronic Trip Unit (AC Only) Breaker T7S IC at 600VAC Trip Unit 25kA PR231/P PR232/P PR331/P PR332/P PR332/P PR332/P Adjustment 3-Pole, 600VAC Part Number LS/I LSI LSIG LI LSI LSIG T7S1200BW T7S1200CW T7S1200EW T7S1200PW T7S1200RW T7S1200SW List Price 4-Pole, 600VAC Part Number List Price T7S1200BW-4 T7S1200CW-4 T7S1200EW-4 T7S1200PW-4 T7S1200RW-4 T7S1200SW-4 T7H-1000A Frame, Electronic Trip Unit (AC Only) Breaker T7H IC at 600VAC Trip Unit 50kA PR231/P PR232/P PR331/P PR332/P PR332/P PR332/P Adjustment 3-Pole, 600VAC Part Number LS/I LSI LSIG LI LSI LSIG T7H1000BW T7H1000CW T7H1000EW T7H1000PW T7H1000RW T7H1000SW List Price 4-Pole, 600VAC Part Number List Price T7H1000BW-4 T7H1000CW-4 T7H1000EW-4 T7H1000PW-4 T7H1000RW-4 T7H1000SW-4 T7H-1200A Frame, Electronic Trip Unit (AC Only) Breaker T7H IC at 600VAC Trip Unit 50kA PR231/P PR232/P PR331/P PR332/P PR332/P PR332/P Adjustment 3-Pole, 600VAC Part Number LS/I LSI LSIG LI LSI LSIG T7H1200BW T7H1200CW T7H1200EW T7H1200PW T7H1200RW T7H1200SW List Price 4-Pole, 600VAC Part Number List Price T7H1200BW-4 T7H1200CW-4 T7H1200EW-4 T7H1200PW-4 T7H1200RW-4 T7H1200SW-4 T7L-1000A Frame, Electronic Trip Unit (AC Only) Breaker T7L IC at 600VAC Trip Unit 65kA PR231/P PR232/P PR331/P PR332/P PR332/P PR332/P Adjustment LS/I LSI LSIG LI LSI LSIG 3-Pole, 600VAC Part Number List Price T7L1000BW T7L1000CW T7L1000EW T7L1000PW T7L1000RW T7L1000SW 4-Pole, 600VAC Part Number List Price T7L1000BW-4 T7L1000CW-4 T7L1000EW-4 T7L1000PW-4 T7L1000RW-4 T7L1000SW-4 T7L-1200A Frame, Electronic Trip Unit (AC Only) Breaker T7L 32 AC1615S - 03/10 IC at 600VAC Trip Unit 65kA PR231/P PR232/P PR331/P PR332/P PR332/P PR332/P Adjustment LS/I LSI LSIG LI LSI LSIG 3-Pole, 600VAC Part Number List Price T7L1200BW T7L1200CW T7L1200EW T7L1200PW T7L1200RW T7L1200SW Discount Schedule DS-ST 4-Pole, 600VAC Part Number List Price T7L1200BW-4 T7L1200CW-4 T7L1200EW-4 T7L1200PW-4 T7L1200RW-4 T7L1200SW-4 ABB T7M 1000A / 1200A, 600VAC ∆ Electronic (AC Only) T7 T7MS-1000A Frame, Electronic Trip Unit (AC Only) Breaker T7MS IC at 600VAC Trip Unit 25kA PR231/P PR232/P PR331/P PR332/P PR332/P PR332/P Adjustment 3-Pole, 600VAC Part Number LS/I LSI LSIG LI LSI LSIG T7MS1000BW T7MS1000CW T7MS1000EW T7MS1000PW T7MS1000RW T7MS1000SW List Price 4-Pole, 600VAC Part Number List Price T7MS1000BW-4 T7MS1000CW-4 T7MS1000EW-4 T7MS1000PW-4 T7MS1000RW-4 T7MS1000SW-4 T7MS-1200A Frame, Electronic Trip Unit (AC Only) Breaker T7MS IC at 600VAC Trip Unit 25kA PR231/P PR232/P PR331/P PR332/P PR332/P PR332/P Adjustment 3-Pole, 600VAC Part Number LS/I LSI LSIG LI LSI LSIG T7MS1200BW T7MS1200CW T7MS1200EW T7MS1200PW T7MS1200RW T7MS1200SW List Price 4-Pole, 600VAC Part Number List Price T7MS1200BW-4 T7MS1200CW-4 T7MS1200EW-4 T7MS1200PW-4 T7MS1200RW-4 T7MS1200SW-4 T7MH, 1000A Frame, Electronic Trip Unit (AC Only) Breaker T7MH IC at 600VAC Trip Unit 50kA PR231/P PR232/P PR331/P PR332/P PR232/P PR332/P Adjustment 3-Pole, 600VAC Part Number LS/I LSI LSIG LI LSI LSIG T7MH1000BW T7MH1000CW T7MH1000EW T7MH1000PW T7MH1000RW T7MH1000SW List Price 4-Pole, 600VAC Part Number List Price T7MH1000BW-4 T7MH1000CW-4 T7MH1000EW-4 T7MH1000PW-4 T7MH1000RW-4 T7MH1000SW-4 T7MH-1200A Frame, Electronic Trip Unit (AC Only) Breaker T7MH IC at 600VAC Trip Unit 50kA PR231/P PR232/P PR331/P PR332/P PR332/P PR332/P Adjustment 3-Pole, 600VAC Part Number LS/I LSI LSIG LI LSI LSIG T7MH1200BW T7MH1200CW T7MH1200EW T7MH1200PW T7MH1200RW T7MH1200SW List Price 4-Pole, 600VAC Part Number List Price T7MH1200BW-4 T7MH1200CW-4 T7MH1200EW-4 T7MH1200PW-4 T7MH1200RW-4 T7MH1200SW-4 T7ML-1000A Frame, Electronic Trip Unit (AC Only) Breaker T7ML IC at 600VAC Trip Unit 65kA PR231/P PR232/P PR331/P PR332/P PR332/P PR332/P Adjustment 3-Pole, 600VAC Part Number LS/I LSI LSIG LI LSI LSIG T7ML1000BW T7ML1000CW T7ML1000EW T7ML1000PW T7ML1000RW T7ML1000SW List Price 4-Pole, 600VAC Part Number List Price T7ML1000BW-4 T7ML1000CW-4 T7ML1000EW-4 T7ML1000PW-4 T7ML1000RW-4 T7ML1000SW-4 T7ML-1200A Frame, Electronic Trip Unit (AC Only) Breaker T7ML ABB IC at 600VAC Trip Unit 65kA PR231/P PR232/P PR331/P PR332/P PR332/P PR332/P Adjustment 3-Pole, 600VAC Part Number LS/I LSI LSIG LI LSI LSIG T7ML1200BW T7ML1200CW T7ML1200EW T7ML1200PW T7ML1200RW T7ML1200SW List Price Discount Schedule DS-ST 4-Pole, 600VAC Part Number List Price T7ML1200BW-4 T7ML1200CW-4 T7ML1200EW-4 T7ML1200PW-4 T7ML1200RW-4 T7ML1200SW-4 33 AC1615S - 03/10 T7 1000A / 1200A, 600VAC ∆ 100% Rated Electronic (AC Only) T7 T7S-1000A Frame, 100% Rated Electronic Trip Unit (AC Only) Breaker T7SQ IC at 600VAC Trip Unit 25kA PR231/P PR232/P PR331/P PR332/P PR332/P PR332/P Adjustment LS/I LSI LSIG LI LSI LSIG 3-Pole, 600VAC Part Number List Price T7SQ1000BW T7SQ1000CW T7SQ1000EW T7SQ1000PW T7SQ1000RW T7SQ1000SW T7S-1200A Frame, 100% Rated Electronic Trip Unit (AC Only) Breaker T7SQ IC at 600VAC Trip Unit 25kA PR231/P PR232/P PR331/P PR332/P PR332/P PR332/P Adjustment LS/I LSI LSIG LI LSI LSIG 3-Pole, 600VAC Part Number List Price T7SQ1200BW T7SQ1200CW T7SQ1200EW T7SQ1200PW T7SQ1200RW T7SQ1200SW T7H-1000A Frame, 100% Rated Electronic Trip Unit (AC Only) Breaker T7HQ IC at 600VAC Trip Unit 50kA PR231/P PR232/P PR331/P PR332/P PR332/P PR332/P Adjustment LS/I LSI LSIG LI LSI LSIG 3-Pole, 600VAC Part Number List Price T7HQ1000BW T7HQ1000CW T7HQ1000EW T7HQ1000PW T7HQ1000RW T7HQ1000SW T7H-1200A Frame, 100% Rated Electronic Trip Unit (AC Only) Breaker T7HQ IC at 600VAC Trip Unit 50kA PR231/P PR232/P PR331/P PR332/P PR332/P PR332/P Adjustment LS/I LSI LSIG LI LSI LSIG 3-Pole, 600VAC Part Number List Price T7HQ1200BW T7HQ1200CW T7HQ1200EW T7HQ1200PW T7HQ1200RW T7HQ1200SW T7L-1000A Frame, 100% Rated Electronic Trip Unit (AC Only) Breaker T7LQ IC at 600VAC Trip Unit 65kA PR231/P PR232/P PR331/P PR332/P PR332/P PR332/P Adjustment LS/I LSI LSIG LI LSI LSIG 3-Pole, 600VAC Part Number List Price T7LQ1000BW T7LQ1000CW T7LQ1000EW T7LQ1000PW T7LQ1000RW T7LQ1000SW T7L-1200A Frame, 100% Rated Electronic Trip Unit (AC Only) Breaker T7LQ 34 AC1615S - 03/10 IC at 600VAC Trip Unit 65kA PR231/P PR232/P PR331/P PR332/P PR332/P PR332/P Adjustment LS/I LSI LSIG LI LSI LSIG 3-Pole, 600VAC Part Number List Price T7LQ1200BW T7LQ1200CW T7LQ1200EW T7LQ1200PW T7LQ1200RW T7LQ1200SW Discount Schedule DS-ST ABB T7M 1000A / 1200A, 600VAC ∆ 100% Rated Electronic (AC Only) T7 T7MS-1000A Frame, 100% Rated Electronic Trip Unit (AC Only) Breaker T7MSQ IC at 600VAC Trip Unit 25kA PR231/P PR232/P PR331/P PR332/P PR332/P PR332/P Adjustment LS/I LSI LSIG LI LSI LSIG 3-Pole, 600VAC Part Number List Price T7MSQ1000BW T7MSQ1000CW T7MSQ1000EW T7MSQ1000PW T7MSQ1000RW T7MSQ1000SW T7MS-1200A Frame, 100% Rated Electronic Trip Unit (AC Only) Breaker T7MSQ IC at 600VAC Trip Unit 25kA PR231/P PR232/P PR331/P PR332/P PR332/P PR332/P Adjustment LS/I LSI LSIG LI LSI LSIG 3-Pole, 600VAC Part Number List Price T7MSQ1200BW T7MSQ1200CW T7MSQ1200EW T7MSQ1200PW T7MSQ1200RW T7MSQ1200SW T7MH-1000A Frame, 100% Rated Electronic Trip Unit (AC Only) Breaker T7MHQ IC at 600VAC Trip Unit 50kA PR231/P PR232/P PR331/P PR332/P PR332/P PR332/P Adjustment LS/I LSI LSIG LI LSI LSIG 3-Pole, 600VAC Part Number List Price T7MHQ1000BW T7MHQ1000CW T7MHQ1000EW T7MHQ1000PW T7MHQ1000RW T7MHQ1000SW T7MH-1200A Frame, 100% Rated Electronic Trip Unit (AC Only) Breaker T7MHQ IC at 600VAC Trip Unit 50kA PR231/P PR232/P PR331/P PR332/P PR332/P PR332/P Adjustment LS/I LSI LSIG LI LSI LSIG 3-Pole, 600VAC Part Number List Price T7MHQ1200BW T7MHQ1200CW T7MHQ1200EW T7MHQ1200PW T7MHQ1200RW T7MHQ1200SW T7ML-1000A Frame, 100% Rated Electronic Trip Unit (AC Only) Breaker T7MLQ IC at 600VAC Trip Unit 65kA PR231/P PR232/P PR331/P PR332/P PR332/P PR332/P Adjustment LS/I LSI LSIG LI LSI LSIG 3-Pole, 600VAC Part Number List Price T7MLQ1000BW T7MLQ1000CW T7MLQ1000EW T7MLQ1000PW T7MLQ1000RW T7MLQ1000SW T7ML-1200A Frame, 100% Rated Electronic Trip Unit (AC Only) Breaker T7MLQ ABB IC at 600VAC Trip Unit 65kA PR231/P PR232/P PR331/P PR332/P PR332/P PR332/P Adjustment LS/I LSI LSIG LI LSI LSIG 3-Pole, 600VAC Part Number List Price T7MLQ1200BW T7MLQ1200CW T7MLQ1200EW T7MLQ1200PW T7MLQ1200RW T7MLQ1200SW Discount Schedule DS-ST 35 AC1615S - 03/10 T7-T7M 1000A / 1200A, 600VAC ∆ MCP (Instantaneous Only), Molded Case Switch T7 T7-1000/1200A Frame, Motor Control Protection (MCP) Electronic Trip Unit (AC Only) Breaker T7 IC at 600VAC Amps Trip Unit 3-Pole, 600VAC Part Number 25kA 1000 PR231/P-I T7S1000MW 50kA 1000 PR231/P-I T7H1000MW 65kA 1000 PR231/P-I T7L1000MW 25kA 1200 PR231/P-I T7S1200MW 50kA 1200 PR231/P-I T7H1200MW 65kA 1200 PR231/P-I T7L1200MW List Price T7M-1000/1200A Frame, Motor Control Protection (MCP) Electronic Trip Unit (AC Only) Breaker T7M IC at 600VAC Amps Trip Unit 3-Pole, 600VAC Part Number 25kA 1000 PR231/P-I T7MS1000MW 50kA 1000 PR231/P-I T7MH1000MW 65kA 1000 PR231/P-I T7ML1000MW 25kA 1200 PR231/P-I T7MS1200MW 50kA 1200 PR231/P-I T7MH1200MW 65kA 1200 PR231/P-I T7ML1200MW List Price T7/T7M-1200A Frame, Molded Case Switch (AC Only) Breaker IC at 600VAC Amps Magnetic Trip 3-Pole, 600VAC Part Number List Price 4-Pole, 600VAC Part Number T7 50kA 1200 12000 T7H1200DW T7H1200DW-4 T7M 50kA 1200 12000 T7MH1200DW T7MH1200DW-4 36 AC1615S - 03/10 Discount Schedule DS-ST List Price ABB T7-T7M 1000A / 1200A, 600VAC ∆ Accessories T7 Shunt Trips (YO) Frame Size Voltage T7 - T7M 415-440VAC 380-400VAC 240-250VAC/DC 220-240VAC/DC 120-127VAC/DC 110-120VAC/DC 60VAC/DC 48VAC/DC 30VAC/DC 24VAC/DC T7 X1 Shunt trip - UVR Part Number List Price KT7XS1 KT7XS2 KT7XS3 KT7XS4 KT7XS5 KT7XS6 KT7XS7 KT7XS8 KT7XS9 KT7XS0 Undervoltage Release - (UVR) Frame Size Voltage T7 - T7M 415-440VAC 380-400VAC 240-250VAC/DC 220-240VAC/DC 120-127VAC/DC 110-120VAC/DC 60VAC/DC 48VAC/DC 30VAC/DC 24VAC/DC Part Number List Price KT7XU1 KT7XU2 KT7XU3 KT7XU4 KT7XU5 KT7XU6 KT7XU7 KT7XU8 KT7XU9 KT7XU0 Shunt Closing Release (YC) Frame Size Voltage T7M 415-440VAC 380-400VAC 240-250VAC/DC 220-240VAC/DC 120-127VAC/DC 110-120VAC/DC 60VAC/DC 48VAC/DC 30VAC/DC 24VAC/DC Part Number List Price KT7MXC1 KT7MXC2 KT7MXC3 KT7MXC4 KT7MXC5 KT7MXC6 KT7MXC7 KT7MXC8 KT7MXC9 KT7MXC0 Auxiliary Contacts - (AUX) Frame Size Type / Voltage T7-T7M 1 AUX "C" + 1 BA "C" 400VAC 2 AUX "C" 400VAC 1 AUX "C" + 1 BA "C" 24VDC 2 AUX "C" 24VDC 1 S51"C" 250VAC 1 S51"C" 250VAC Part Number List Price KT7AS (1) KT7XAS2 KT7ASL (1) KT7XAS2L KT7XS51 (2) KT7S51 (1) Possible combinations are: T7: a) 1 Aux + 1BA b) 2 Aux, c) 3 Aux + 1BA T7M: a) 2 Aux , b) 4 Aux Spring Charging Motor (M) Frame Size Type / Voltage T7M 380...415VAC 220...250VAC/DC 100/130VAC/DC 48...60VAC/DC 24...30VAC/DC Part Number List Price KT7MXM2 KT7MXM3 KT7MXM5 KT7MXM7 KT7MXM9 (1) For installation on T7 only (2) For installation on T7M only ABB Discount Schedule DS-STA 37 AC1615S - 03/10 T7 T7-T7M 1000A / 1200A, 600VAC ∆ Accessories Standard Cable Terminal (1) Frame T7-T7M 1 Part Number (set of 3) Wire Size (4) 4/0-500 kcmil List Price KT7X1200-3 Part Number (set of 4) List Price KT7X1200-4 (1) Comes standard with high profile terminal covers. Terminal Covers for Fixed Breakers - Low Profile-Kit Includes Two Pieces Frame Part Number (3-Pole) T7-T7M KT7XLTC-3 Part Number (4-Pole) List Price List Price KT7XLTC-4 Terminal Covers for Fixed Breakers - High Profile-Kit Includes Two Pieces Frame Part Number (3-Pole) T7-T7M KT7XHTC-3 Part Number (4-Pole) List Price List Price KT7XHTC-4 Phase Barriers - Low Profile - 100mm - 3.93 in Frame Part Number (3-Pole) T7-T7M KT7PBL-3 Part Number (4-Pole) List Price List Price KT7PBL-4 Phase Barriers - High Profile - 200mm - 7.87 in Frame Part Number (3-Pole) T7-T7M KT7PBH-3 Part Number (4-Pole) List Price List Price KT7PBH-4 Extended Front Terminals - IEC Frame Part Number (3-Pole) T7-T7M KT7EF-3 Part Number (4-Pole) List Price List Price KT7EF-4 Rear Terminals - IEC Frame T7-T7M Part Number (set of 3) List Price Part Number (set of 4) KT7XR-3 List Price KT7XR-4 Variable Depth Handle Operators Frame Mechanism Part Number T7 KT7VD-M List Price List Price Shaft Part Number Handle Part Number OHB175J10X OHY175J10 OHB175L10 KT7VD-H OXP10X500 (19.7”) KT7VD-S (19.7”) Direct Mount Rotary Operator Handle List Price Early Make Contact Frame Breaker Mounting Part Number T7 Fixed, Plug-In KT7RH List Price Frame T7 Part Number List Price KT7EM Padlock Locking Device Frame Style Locking Position Breaker Mounting Part Number T7 T7M PLL PLL OPEN OPEN Fixed, Drawout Fixed, Draw-out KT7LDO KT7MLDO List Price Keylocks for the Rotary Handle Mechanism Frame Style Locking Position Keys Part Number T7 KLF-D KLF-S KLF-S KLF-S KLF-S OPEN OPEN OPEN OPEN OPEN Different Same key # 20005 Same key # 20006 Same key # 20007 Same key # 20008 KT7KLFD KT7KLFS-20005 KT7KLFS-20006 KT7KLFS-20007 KT7KLFS-20008 Style Locking Position Keys Part Number KLF-D KLF-S KLF-S KLF-S KLF-S KLF-D KLF-S KLF-S KLF-S KLF-S OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN Different Same key # 20005 Same key # 20006 Same key # 20007 Same key # 20008 Different Same key # 20005 Same key # 20006 Same key # 20007 Same key # 20008 KT7KLCD KT7KLCS-20005 KT7KLCS-20006 KT7KLCS-20007 KT7KLCS-20008 KT7MKLCD KT7MKLCS-20005 KT7MKLCS-20006 KT7MKLCS-20007 KT7MKLCS-20008 List Price Keylocks on the Circuit-Breaker Frame T7 T7M 38 AC1615S - 03/10 Discount Schedule DS-STA List Price ABB T7-T7M 1000A / 1200A, 600VAC ∆ Accessories T7 Draw-Out Kits Part Number Adaptor Moving Part Item T7 - 3 pole with RC-RC T7 - 4 pole with RC-RC List Price KT7WMK KT7WMK-4 Part Number Fixed Part List Price KT7WFRC KT7WFRC-4 Sliding Contact Blocks — T7-Draw-Out (1) Moving Part Breaker Item Left Block Spring charging motor Spring charged contact Ready to close contact Early auxiliary contact Contact for trip coil release trip Trip rest Center Block PR331 PR332 Right Block Auxiliary contacts Shunt trip Closing Coil Undervoltage release List Price KT7XSCMP-L Fixed Part Cradle List Price KT7SCFP-L (T7) KT7MXSCFP-L (T7M) KT7XSCMP-C KT7XSCFP-C KT7XSCMP-R KT7XSCFP-R Position Key Lock (Fixed Part) — T7 - T7M Part Number Item Different key Same key #20005 Same key #20006 Same key #20007 Same key #20008 List Price KT7XPL-D KT7XPL-20005 KT7XPL-20006 KT7XPL-20007 KT7XPL-20008 Locks drawout breaker in racked-in / test isolation / racked-out position. Position Key Lock Accessory (Fixed Part) — T7 - T7M Part Number Item Key lock accessory List Price KT7XPLA Accessory added to position key lock allows breaker to be locked in racked-out position only. Mechanical Interlocks Part Number Item T7 (2) Cable T7 Mech. interlock plate-fixed Mech. interlock plate-draw-out List Price KT7XMLC KT7XMLPW KT7XMLPF Neutral Current Transformers (Required for 4-Wire Ground Fault System) Part Number Frame T7 400...1200A KT7XNCT1200 Frame Rating Plug Part Number T7 400A 600A 800A 1000A 1200A KT70400RP KT70600RP KT70800RP KT71000RP KT71200RP List Price Rating Plugs List Price Mechanical Accessories Part Number Item Flange T7 KT7XFCD Mech. operation counter KT7XEMC IP54 door cover KT7XDC List Price (1) If at least one of the accessories in table is installed on the breaker - respective pair of contact blocks must be installed on the fixed part (cradle) and the moving part. (breaker) (2) To interlock two circuit breakers, you have to order a cable kit and two plates. ABB Discount Schedule DS-STA 39 AC1615S - 03/10 T7 / T7M 1000A / 1200A, 600VAC ∆ Part-Numbering System T7 T7 Locking Provisions: X = None, A = Keylock, B = Button guard, C = Padlock Provision (open), D = Withdrawable Position Lock (Connected, test and disconnected positions), E = Withdrawable Position Lock (Test and disconnected positions) Accessories X = None, A = Mechanical counter Undervoltage: 0 = C= E= G= J = None, A = 24VAC/DC, B = 30VAC/DC, 48VAC/DC, D = 60VAC/DC, 110..120VAC/DC, F = 120..127VAC/DC, 220..240VAC/DC, H = 240..250VAC/DC, 380..400VAC, K = 415..440VAC Shunt Trip: 0 = None, A = 24VAC/DC, B = 30VAC/DC, C = 48VAC/DC, D = 60VAC/DC, E = 110..120VAC/DC, F = 120..127VAC/DC, G = 220..240VAC/DC, H = 240..250VAC/DC, J = 380..400VAC, K = 415..440VAC Spring Charging Motor: 0 = None, A = 24..30VAC/DC, B = 48..60VAC/DC, C = 100..130VAC/DC, D = 220..250VAC/DC, E = 380..415VAC/DC Aux Contacts: 0 = C= F = K= None, A = 1 Form C + 1BA 400VAC (T7), B = 1 Form C + 1BA 24VDC (T7), 2 Form C 400VAC (T7-T7M), D = 2 Form C 24VDC (T7-T7M), E = S51 250VAC (T7), S51 250VAC (T7M), G = A+C (T7), H = B+D (T7), I = C+E (T7), J = C+F (T7M), D+E (T7), L = D+F (T7M), M = C+C (T7M), N = D+D (T7M) Closing Coil: 0 = D= G= J = None, A = 24VAC/DC, B = 30VAC/DC, C = 48VAC/DC, 60VAC/DC, E = 110..120VAC/DC, F = 120..127VAC/DC, 220..240VAC/DC, H = 240..250VAC/DC, 380..400VAC, K = 415..440VAC Trip Unit Accessories: 0 = None, A = PR330V, B = PR330/D-M, C = A + B Trip Unit: X = Non-Automatic (MCS), B = PR231/P-LS/I, C = PR232/P-LSI, E = PR331/P-LSIG, P = PR332/P-LI, R = PR332/P-LSI, S = PR332/P-LSIG Rating Plug: 0 = None Non-Automatic (MCS), A = 400, B = 600, C = 800, D = 1000A, E = 1200 Frame Amp Rating: 1 = 1000A (toggle) 2 = 1200A (toggle) P =1000A (motorized) B =1200A (motorized) Version: B = UL Fixed, Q = UL Fixed 100% Rated, 0 = Fixed Non-Automatic (MCS) W = UL Draw-out1, X = UL Draw-out 100%1, Y = Draw-out non-automatic (1) Breaking Capacity S, H, L (1) Fixed part and accessories to be ordered separately 40 AC1615S - 03/10 ABB T8V 1600A / 2000A / 2500A / 3000A Insulated Case Circuit Breaker T8 Dimensions 3P Version: 15.00" H x 16.8" W x 11.2"D Weight 161 (lbs) 1600A/2000A/2500A 236 (lbs) 3000A T8V The Tmax family, conforming to the UL489 and CSA C22.2 No. 5.0 Standards, is enriched with the TmaxT8 size, which allows 3000 A to be reached. Also available in the 1600A, 2000A and 2500A frames, Tmax T8 is equipped with the same electronic trip units as Tmax T7 thereby guaranteeing extremely high performances able to satisfy all installation requirements. Tmax T8 is able to interrupt the following short-circuit currents: 125kA@480VAC and 100kA@600 VAC. • Available in 3 and 4 pole versions • Four different frame ratings, 1600, 2000, 2500 & 3000 Amps • Available 100% rated version up to 3000A • Installation in vertical position only UL489 / CSA C22.2 Interrupting Capacity (kA RMS) Voltage V 240VAC 125 480VAC 125 600VAC 100 IEC 60947-2 Interrupting Capacity (kA RMS) • • • Wide range of CSA/UL field-installable accessories Solid state trip unit available in three different versions: - PR331/P-LSI - PR331/P-LSIG - PR332/P-LI (LCD display) - PR332/P-LSI (LCD display) - PR332/P-LSIG (LCD display) Voltage V 230VAC 130 415VAC 130 440VAC 130 500VAC 100 600VAC 80 The ability to add internal modules for flexible and precise configuration: Optional modules includes: - Voltage module - Signaling module - Communications module ABB 41 AC1615S - 03/10 T8V 1600A / 2000A / 2500A / 3000A, 600VAC ∆ Electronic (AC Only) T8 T8-1600A Frame, Electronic Trip Unit (AC Only) Breaker T8V IC at 600VAC Trip Unit 100kA PR331/P PR331/P PR332/P PR332/P PR332/P Adjustment LSI LSIG LI LSI LSIG 3-Pole, 600VAC Part Number List Price T8V16CW T8V16EW T8V16PW T8V16RW T8V16SW 4-Pole, 600VAC Part Number List Price T8V16CW-4 T8V16EW-4 T8V16PW-4 T8V16RW-4 T8V16SW-4 T8-2000A Frame, Electronic Trip Unit (AC Only) Breaker T8V IC at 600VAC Trip Unit 100kA PR331/P PR331/P PR332/P PR332/P PR332/P Adjustment LSI LSIG LI LSI LSIG 3-Pole, 600VAC Part Number List Price T8V20CW T8V20EW T8V20PW T8V20RW T8V20SW 4-Pole, 600VAC Part Number List Price T8V20CW-4 T8V20EW-4 T8V20PW-4 T8V20RW-4 T8V20SW-4 T8-2500A Frame, Electronic Trip Unit (AC Only) Breaker T8V IC at 600VAC Trip Unit 100kA PR331/P PR331/P PR332/P PR332/P PR332/P Adjustment LSI LSIG LI LSI LSIG 3-Pole, 600VAC Part Number List Price T8V25CW T8V25EW T8V25PW T8V25RW T8V25SW 4-Pole, 600VAC Part Number List Price T8V25CW-4 T8V25EW-4 T8V25PW-4 T8V25RW-4 T8V25SW-4 T8-3000A Frame, Electronic Trip Unit (AC Only)1 Breaker T8V IC at 600VAC Trip Unit 100kA PR331/P PR331/P PR332/P PR332/P PR332/P Adjustment LSI LSIG LI LSI LSIG 3-Pole, 600VAC Part Number List Price T8V30CW T8V30EW T8V30PW T8V30RW T8V30SW 4-Pole, 600VAC Part Number List Price T8V30CW-4 T8V30EW-4 T8V30PW-4 T8V30RW-4 T8V30SW-4 T8-3000A Frame, Molded Case Switch (AC Only)1 Breaker Rating Magnetic Override 3-Pole, 600VAC Part Number T8V-D 2000A 2500A 1 3000A (1) 40000A T8V20DW T8V25DW T8V30DW List Price 4-Pole, 600VAC Part Number List Price T8V20DW-4 T8V25DW-4 T8V30DW-4 (1) Vertical terminals only 42 AC1615S - 03/10 Discount Schedule DS-ST8 ABB T8V 1600A / 2000A / 2500A / 3000A, 600VAC ∆ 100% Rated Electronic (AC Only) T8 T8-1600A Frame, 100% Rated Electronic Trip Unit (AC Only) Breaker T8VQ IC at 600VAC Trip Unit 100kA PR331/P PR331/P PR332/P PR332/P PR332/P Adjustment LSI LSIG LI LSI LSIG 3-Pole, 600VAC Part Number List Price T8VQ16CW T8VQ16EW T8VQ16PW T8VQ16RW T8VQ16SW T8-2000A Frame, 100% Rated Electronic Trip Unit (AC Only) Breaker T8VQ IC at 600VAC Trip Unit 100kA PR331/P PR331/P PR332/P PR332/P PR332/P Adjustment LSI LSIG LI LSI LSIG 3-Pole, 600VAC Part Number List Price T8VQ20CW T8VQ20EW T8VQ20PW T8VQ20RW T8VQ20SW T8-2500A Frame, 100% Rated Electronic Trip Unit (AC Only) Breaker T8VQ IC at 600VAC Trip Unit 100kA PR331/P PR331/P PR332/P PR332/P PR332/P Adjustment LSI LSIG LI LSI LSIG 3-Pole, 600VAC Part Number List Price T8VQ25CW T8VQ25EW T8VQ25PW T8VQ25RW T8VQ25SW Note: vertical terminals only T8-3000A Frame, 100% Rated Electronic Trip Unit (AC Only) Breaker T8VQ IC at 600VAC Trip Unit 100kA PR331/P PR331/P PR332/P PR332/P PR332/P Adjustment LSI LSIG LI LSI LSIG 3-Pole, 600VAC Part Number List Price T8VQ30CW T8VQ30EW T8VQ30PW T8VQ30RW T8VQ30SW Note: vertical terminals only ABB Discount Schedule DS-ST8 43 AC1615S - 03/10 T8V 1600A / 2000A / 2500A / 3000A, 600VAC ∆ Accessories T8 1SDC200131F0001 Shunt Trips (YO) and Closing Coils (YC) Frame Size Voltage YO Part Number T8 24VDC 30VAC/DC 48VAC/DC 60VAC/DC 110/120VAC/DC 120/127VAC/DC 220/240VAC/DC 250VAC/DC 380/400VAC 440/480VAC KT8ES0 KT8ES9 KT8ES8 KT8ES7 KT8ES6 KT8ES5 KT8ES4 KT8ES3 KT8ES2 KT8ES1 List Price YC Part Number List Price KT8EC0 KT8EC9 KT8EC8 KT8EC7 KT8EC6 KT8EC5 KT8EC4 KT8EC3 KT8EC2 KT8EC1 Undervoltage Release (UVR) or Additional Shunt Trip (YO2) 1SDC200132F0001 Frame Size YO Part Number Voltage List Price 24VDC KT8EU0 30VAC/DC KT8EU9 48VAC/DC KT8EU8 60VAC/DC KT8EU7 110/120VAC/DC KT8EU6 T8 120/127VAC/DC KT8EU5 220/240VAC/DC KT8EU4 250VAC/DC KT8EU3 380/400VAC KT8EU2 440/480VAC KT8EU1 Note: UVR and YO2 are mutually exclusive (only one device can be installed) YC Part Number List Price KT8ES0-2 KT8ES9-2 KT8ES8-2 KT8ES7-2 KT8ES6-2 KT8ES5-2 KT8ES4-2 KT8ES3-2 KT8ES2-2 KT8ES1-2 1SDC200139F0001 Stored Energy Motor (M) Frame Size Voltage Part Number T8 24/30VAC/DC 48/60VAC/DC 100/130VAC/DC 220/250VAC/DC KT8EM9 KT8EM7 KT8EM5 KT8EM3 Voltage Part Number Signaling Contacts 1SDC200145F0001 Frame Size 44 AC1615S - 03/10 List Price 4 aux. cont. open/close PR331 4 aux. cont. open/close PR332 4 aux. cont. open/close for PR232-331 (low power 3 ABB 103
DEL-KT3S4 价格&库存

很抱歉,暂时无法提供与“DEL-KT3S4”相匹配的价格&库存,您可以联系我们找货

免费人工找货