EF96-100

EF96-100

  • 厂商:

    ABB

  • 封装:

  • 描述:

    ABB - EF96-100 - ELECTRONIC OVERLOAD RELAY, 3 POLE, 690V

  • 数据手册
  • 价格&库存
EF96-100 数据手册
EF96-100 General Information Extended Product Type: Product ID: EAN: Catalog Description: Long Description: EF96-100 1SAX341001R1101 4013614442247 EF96-100 Electronic Overload Relay The EF96-100 is an self-supplied electronic overload relay, which means no extra external supply is needed. It offers reliable and fast protection for motors in the event of overload or phase failure. Easy to use like a thermal overload relay and compatible with standard motor applications, the electronic overload relay is convincing, above all, due to its wide setting range, high accuracy, high operational temperature range and the possibility to select a trip class (10E, 20E, 30E). Further features are the temperature compensation, trip contact (NC), signal contact (NO), automatic- or manual reset selectable, trip-free mechanism, STOP- and Test function and a trip indication. The overload relays are connected directly to the contactors. Single mounting kits are available as accessory. Categories Products » Low Voltage Products and Systems » Control Products » Contactors » Electronic Overload Relays Ordering Minimum Order Quantity: Customs Tariff Number: EAN: 1 piece 85364900 4013614442247 Dimensions Product Net Height: Product Net Depth: Product Net Weight: Product Net Width: 132.7 mm 105.2 mm 0.802 kg 70 mm Container Information Package Level 1 Width: Package Level 1 Height: Package Level 1 Length: Package Level 1 Gross Weight: Package Level 2 Units: Package Level 2 Width: Package Level 2 Height: Package Level 2 Length: Package Level 2 Gross Weight: Package Level 2 EAN: Package Level 1 Units: 139 mm 107 mm 75.5 mm 0.857 kg 20 piece 393 mm 227 mm 290 mm 17.703 kg 4013614483387 1 piece Technical Rated Operational Voltage: Auxiliary Circuit 600 V AC/DC Main Circuit 1000 V AC Rated Operational Current (Ie): 100 A Rated Operational Current AC-3 (Ie): 100 A Rated Frequency (f): Auxiliary Circuit 50 Hz Auxiliary Circuit 60 Hz Auxiliary Circuit DC Main Circuit 50 Hz Main Circuit 60 Hz Rated Impulse Withstand Voltage Auxiliary Circuit 6 kV (Uimp): Main Circuit 8 kV Rated Insulation Voltage (Ui): 1000 V Number of Poles: 3 Number of Auxiliary Contacts NC: 1 Number of Auxiliary Contacts NO: 1 Number of Protected Poles: 3 Conventional Free-air Thermal Auxiliary Circuit NC 6 A Current (Ith): Auxiliary Circuit NO 6 A Rated Operational Current AC-15 (240 V) NC 3 A (Ie): (240 V) NO 3 A (400 V) NC 1.1 A Rated Operational Current DC-13 (Ie): Degree of Protection: Pollution Degree: Connecting Capacity Auxiliary Circuit: Connecting Capacity Main Circuit: Tightening Torque: Wire Stripping Length: Recommended Screw Driver: Mounting Position: Power Loss: Suitable For: Standards: Setting Range: (400 V) NO 1.1 A (500 V) NC 0.75 A (500 V) NO 0.75 A (125 V) NC 0.55 A (125 V) NO 0.5 A (24 V) NC 1.5 A (24 V) NO 1.5 A (250 V) NC 0.27 A (250 V) NO 0.27 A (60 V) NC 0.55 A (60 V) NO 0.55 A Housing IP20 Main Circuit Terminals IP10 3 Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 1/2x 0.75 ... 2.5 mm² Flexible 1/2x 0.75 ... 2.5 mm² Rigid 1/2x 1 ... 4 mm² Flexible with Ferrule 1x 6 ... 50 mm² Flexible with Ferrule 2x 6 ... 35 mm² Flexible with Insulated Ferrule 1x 6 ... 50 mm² Flexible with Insulated Ferrule 2x 2 ... 35 mm² Flexible 1x 6 ... 70 mm² Flexible 2x 6 ... 35 mm² Rigid 1x 6 ... 70 mm² Rigid 2x 6 ... 35 mm² Auxiliary Circuit 0.8 ... 1.2 N·m Main Circuit 6 N·m Auxiliary Circuit 9 mm Main Circuit 20 mm Auxiliary Circuit Pozidriv 2 Main Circuit Hexagon 4 Position 1 to 6 at Rated Operating Conditions per Pole 0.117 ... 0.9 W AF80 AF96 IEC/EN 60947-1 IEC/EN 60947-4-1 IEC/EN 60947-5-1 UL 60947-1 UL 60947-4-1 36 ... 100 A Environmental Ambient Air Temperature Compensation: Maximum Operating Altitude Permissible: Resistance to Shock acc. to IEC 60068-2-27: Resistance to Vibrations acc. to IEC 60068-2-6: RoHS Status: Ambient Air Temperature: Yes 2000 m 11 ms Pulse 25g 5g / 3 ... 150 Hz Following EU Directive 2011/65/EC Operation -25 ... +70 °C Operation Compensated -25 ... +70 °C Storage -50 ... +85 °C Technical UL/CSA Ampere Rating UL/CSA: Contact Rating UL/CSA: Connecting Capacity Main Circuit UL/CSA: Connecting Capacity Auxiliary Circuit UL/CSA: Tightening Torque UL/CSA: Maximum Operating Voltage UL/CSA: 100 A (NC:) B600 (NC:) Q600 (NO:) B600 (NO:) Q600 Flexible 1/2x 8-2 AWG Stranded 1/2x 8-2 AWG Flexible 1/2x 18-10 AWG Stranded 1/2x 18-10 AWG Auxiliary Circuit 7 ... 1 in·lb Main Circuit 70 in·lb Main Circuit 600 V AC Certificates and Declarations (Document Number) Data Sheet, Technical Information (Part 2): Instructions and Manuals: Instructions and Manuals (Part 2): ABS Certificate: ATEX Certificate: BV Certificate: CB Certificate: CCC Certificate: cUL Certificate: Data Sheet, Technical Information: Declaration of Conformity - CE: DNV Certificate: EAC Certificate: GOST Certificate: LR Certificate: RINA Certificate: RMRS Certificate: RoHS Information: UL Certificate: 1SAX100509F0001 1SAX100510F0001 2CDC107027M6801 2CDC107043M6801 1SAA941002-0101 1SAA941004-3901 1SAA941002-0201 1SAA942010-2001 1SAA942006-3802 cUL_E48139 2CDC107041D0201 1SAD938512-0180 1SAD938508-0180 1SAA941003-0301 1SAA941003-2701 1SAA941001-2701 1SAA941002-0501 RINA_ELE376813CS 1SAA941001-0701 1SAA942001-4406 UL_E48139 Classifications E-nummer: ETIM 4: ETIM 5: ETIM 6: eClass: UNSPSC: Object Classification Code: 3210246 EC001080 - Electronic overload relay EC001080 - Electronic overload relay EC001080 - Electronic overload relay 7.0 27371502 39121521 F
EF96-100 价格&库存

很抱歉,暂时无法提供与“EF96-100”相匹配的价格&库存,您可以联系我们找货

免费人工找货