EQW006 Series, Eight Brick Power Modules: DC-DC Converter
36 – 75Vdc Input; 12Vdc Output; 6A Output Current
Features
RoHS Compliant
Compliant to RoHS EU Directive 2011/65/EU (Z versions)
Compliant to RoHS EU Directive 2011/65/EU under
exemption 7b (Lead solder exemption). Exemption 7b will
expire after June 1, 2016 at which time this produc twill no
longer be RoHS compliant (non-Z versions)
Delivers up to 6A output current
High efficiency: 91.5% at 12V full load (VIN = 48Vdc)
Industry-Standard Eighth-brick foot print:
57.9 mm x 22.8 mm x 8.52 mm
(2.28 in x 0.90 in x 0.335 in)
Applications
Distributed power architectures
Wireless networks
Access and optical network Equipment
Enterprise Networks
Latest generation IC’s (DSP, FPGA, ASIC) and
Microprocessor powered applications
Options
Remote On/Off logic (positive or negative)
Surface Mount (-S Suffix)
Short Pins
Low output ripple and noise
Surface mount or through hole
Cost efficient open frame design
Remote On/Off positive logic (primary referenced)
Remote Sense
Adjustable output voltage
Constant switching frequency (330 kHz)
Output over voltage and over current protection
Over temperature protection
Input undervoltage lockout
Wide operating temperature range (-40°C to 85°C)
UL* 60950 Recognized, CSA† C22.2 No. 60950-00 Certified,
and VDE‡ 0805 (IEC60950, 3rd edition) Licensed
CE mark meets 73/23/EEC and 93/68/EEC directives§
ISO** 9001 and ISO14001 certified manufacturing facilities
Meets the voltage and current requirements for ETSI 300132-2 and complies with and licensed for Basic insulation
rating per IEC60950 3rd edition
Description
The EQW series, Eighth-brick power modules are isolated dc-dc converters that can deliver up to 6A of output current and
provide a precisely regulated output voltage of 12Vdc over a wide range of input voltages (Vi = 36 -75Vdc). The modules
achieve full load efficiency of 91.5% at 12Vdc output voltage. The open frame modules construction, available in both
surface-mount and through-hole packaging, enable designers to develop cost- and space-efficient solutions. Standard
features include remote On/Off, remote sense, output voltage adjustment, over voltage, over current and over
temperature protection.
* UL is a registered trademark of Underwriters Laboratories, Inc.
†
CSA is a registered trademark of Canadian Standards Association.
VDE is a trademark of Verband Deutscher Elektrotechniker e.V.
** ISO is a registered trademark of the International Organization of Standards
‡
October 1, 2015
©2012 General Electric Company. All rights reserved.
GE
Data Sheet
EQW006 Series, Eight Brick Power Modules: DC-DC Converter
36 – 75Vdc Input; 12Vdc Output; 6A Output Current
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute
stress ratings only, functional operation of the device is not implied at these or any other conditions in excess of those
given in the operations sections of the data sheet. Exposure to absolute maximum ratings for extended periods can
adversely affect the device reliability.
Parameter
Device
Symbol
Min
Max
Unit
Input Voltage
Continuous
All
VIN
-0.3
80
Vdc
Transient (100 ms)
All
VIN,trans
-0.3
100
Vdc
All
TA
-40
85
°C
Storage Temperature
All
Tstg
-55
125
°C
I/O Isolation voltage (100% factory Hi-Pot tested)
All
1500
Vdc
Operating Ambient Temperature
(see Thermal Considerations section)
Electrical Specifications
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions.
Parameter
Device
Symbol
Min
Typ
36
48
Max
Unit
Operating Input Voltage
All
VIN
Maximum Input Current
All
IIN,max
75
Vdc
2.5
Adc
All
IIN,No load
75
mA
All
IIN,stand-by
3
mA
Inrush Transient
All
I2t
Input Reflected Ripple Current, peak-to-peak
(5Hz to 20MHz, 1μH source impedance; VIN, min to VIN,
max, IO= IOmax ; See Test configuration section)
All
13
Input Ripple Rejection (120Hz)
All
50
(VIN= VIN, min to VIN, max, IO=IO, max)
Input No Load Current
(VIN = VIN, nom, IO = 0, module enabled)
Input Stand-by Current
(VIN = VIN, nom, module disabled)
EMC,EN5022
1
A2s
mAp-p
dB
See EMC Considerations section
CAUTION: This power module is not internally fused. An input line fuse must always be used.
This power module can be used in a wide variety of applications, ranging from simple standalone operation to an
integrated part of sophisticated power architectures. To preserve maximum flexibility, internal fusing is not included,
however, to achieve maximum safety and system protection, always use an input line fuse. The safety agencies require a
time-delay fuse with a maximum rating of 6 A (see Safety Considerations section). Based on the information provided in
this data sheet on inrush energy and maximum dc input current, the same type of fuse with a lower rating can be used.
Refer to the fuse manufacturer’s data sheet for further information.
October 1, 2015
©2012 General Electric Company. All rights reserved.
Page 2
GE
Data Sheet
EQW006 Series, Eight Brick Power Modules: DC-DC Converter
36 – 75Vdc Input; 12Vdc Output; 6A Output Current
Electrical Specifications (continued)
Parameter
Output Voltage Set-point
Device
Symbol
Min
Typ
Max
Unit
All
VO, set
11.8
12.0
12.2
Vdc
All
VO
11.6
12.4
Vdc
All
VO
10.8
13.2
Vdc
(VIN=IN, min, IO=IO, max, TA=25°C)
Output Voltage
(Over all operating input voltage, resistive load, and
temperature conditions until end of life)
Adjustment Range
Selected by external resistor
Output Regulation
Line (VIN=VIN, min to VIN, max)
All
0.1
% VO, set
Load (IO=IO, min to IO, max)
All
0.1
% VO, set
Temperature (Tref=TA, min to TA, max)
All
0.2
% VO, set
RMS (5Hz to 20MHz bandwidth)
All
15
25
mVrms
Peak-to-Peak (5Hz to 20MHz bandwidth)
All
mVpk-pk
Output Ripple and Noise on nominal output
measured with 10 F Tantalum, 1 F ceramic
(VIN=VIN, nom ,IO= IO, max , TA=TA, min to TA, max)
40
75
External Capacitance
All
CO, max
0
1000
μF
Output Current
All
Io
0
6
Adc
All
IO, lim
7.0
Adc
All
IO, s/c
0.5
Adc
All
η
91.5
%
All
fsw
300