GE
Data Sheet
EQW010-040 Series (Eighth-Brick) DC-DC Converter Power Modules
36–75Vdc Input; 1.0 to 12.0Vdc Output; 10 to 40A Output Current
Features
RoHS Compliant
Compliant to RoHS EU Directive 2011/65/EU (Z
versions)
Compliant to RoHS EU Directive 2011/65/EU under
exemption 7b (Lead solder exemption). Exemption 7b
will expire after June 1, 2016 at which time this produc
twill no longer be RoHS compliant (non-Z versions)
Compatible in a Pb-free or SnPb reflow environment
High efficiency – 92% at 3.3V full load
Industry standard, DOSA compliant, Eighth brick
footprint
57.9mm x 22.9mm x 8.5mm
(2.28in x 0.9in x 0.335in)
Applications
Distributed power architectures
Wireless networks
Access and optical network Equipment
Enterprise Networks
Latest generation IC’s (DSP, FPGA, ASIC) and
Microprocessor powered applications
Options
Wide Input voltage range: 36-75 Vdc
Tightly regulated output
Constant switching frequency
Positive Remote On/Off logic
Input under/over voltage protection
Output overcurrent/voltage protection
Over-temperature protection
Remote sense
No minimum load required
No reverse current during output shutdown
Negative Remote On/Off logic
Over current/Over temperature/Over voltage
protections (Auto-restart)
Heat plate versions (-C, -H)
Output Voltage adjust: 80% to 110% of Vo,nom
Surface Mount version (-S)
Operating temperature range (-40°C to 85°C)
UL* 60950-1Recognized, CSA† C22.2 No. 60950-1-03
Certified, and VDE‡ 0805:2001-12 (EN60950-1) Licensed
CE mark meets 73/23/EEC and 96/68/EEC directives§
Meets the voltage and current requirements for ETSI
300-132-2 and complies with and licensed for Basic
insulation rating per EN60950-1
ISO**9001 and ISO 14001 certified manufacturing
facilities
Description
The EQW010/040 series DC-DC converters are designed to provide up to 40A output current in an industry standard eighth
brick package. These DC-DC converters operate over an input voltage range of 36 to 75 Vdc and provide a single, preciselyregulated output. The output is isolated from the input, allowing versatile polarity configurations and grounding
connections. Built in filtering for both the input and output minimizes the need for external filtering.
October 1, 2015
©2012 General Electric Company. All rights reserved.
GE
Data Sheet
EQW010-040 Series (Eighth-Brick) DC-DC Converter Power Modules
36–75Vdc Input; 1.0 to 12.0Vdc Output; 10 to 40A Output Current
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute
stress ratings only, functional operation of the device is not implied at these or any other conditions in excess of those
given in the operations sections of the data sheet. Exposure to absolute maximum ratings for extended periods can
adversely affect the device reliability.
Parameter
Device
Symbol
Min
Max
Unit
All
VIN
-0.3
80
Vdc
Input Voltage
Continuous
Transient (100 ms)
All
VIN,trans
-0.3
100
Vdc
All
TA
-40
85
°C
Storage Temperature
All
Tstg
-55
125
°C
I/O Isolation voltage (100% factory Hi-Pot tested)
All
1500
Vdc
Operating Ambient Temperature
(see Thermal Considerations section)
Electrical Specifications
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions.
Parameter
Device
Symbol
Min
Typ
Max
Unit
Operating Input Voltage
All
VIN
36
48
75
Vdc
Maximum Input Current
Adc
All, except B
IIN,max
3.2
3.5
(VIN= VIN, min to VIN, max, IO=IO, max)
B
IIN,max
3.4
3.7
Adc
Input No Load Current
All
IIN,No load
75
mA
All
IIN,stand-by
22
mA
Inrush Transient
All
I2t
0.5
A2s
Input Reflected Ripple Current, peak-to-peak
(5Hz to 20MHz, 1μH source impedance; VIN, min to VIN,
max, IO= IOmax ; See Test configuration section)
All
20
mAp-p
Input Ripple Rejection (120Hz)
All
(VIN = VIN, nom, IO = 0, module enabled)
Input Stand-by Current
(VIN = VIN, nom, module disabled)
50
dB
CAUTION: This power module is not internally fused. An input line fuse must always be used.
This power module can be used in a wide variety of applications, ranging from simple standalone operation to an
integrated part of sophisticated power architectures. To preserve maximum flexibility, internal fusing is not included,
however, to achieve maximum safety and system protection, always use an input line fuse. The safety agencies require a
time-delay fuse with a maximum rating of 8 A (see Safety Considerations section). Based on the information provided in
this data sheet on inrush energy and maximum dc input current, the same type of fuse with a lower rating can be used.
Refer to the fuse manufacturer’s data sheet for further information.
October 1, 2015
©2012 General Electric Company. All rights reserved.
Page 2
GE
Data Sheet
EQW010-040 Series (Eighth-Brick) DC-DC Converter Power Modules
36–75Vdc Input; 1.0 to 12.0Vdc Output; 10 to 40A Output Current
Electrical Specifications (continued)
Parameter
Nominal Output Voltage Set-point
VIN=VIN, min, IO=IO, max, TA=25°C)
Output Voltage
(Over all operating input voltage, resistive load,
and temperature conditions until end of life)
Output Regulation
Line (VIN=VIN, min to VIN, max)
Load (IO=IO, min to IO, max)
Temperature (Tref=TA, min to TA, max)
Output Ripple and Noise on nominal output
(VIN=VIN, nom ,IO= IO, max , TA=TA, min to TA, max)
RMS (5Hz to 20MHz bandwidth)
Device
Symbol
Min
Typ
Max
B
VO, set
11.76
12.0
12.24
Unit
Vdc
A
VO, set
4.90
5.0
5.10
Vdc
F
VO, set
3.23
3.3
3.37
Vdc
G
VO, set
2.45
2.5
2.55
Vdc
Y
VO, set
1.76
1.8
1.84
Vdc
M
VO, set
1.47
1.5
1.53
Vdc
P
VO, set
1.18
1.2
1.22
Vdc
S1R0
VO, set
0.98
1.0
1.02
Vdc
All
VO
-3.0
+3.0
% VO, set
0.2
5
0.2
5
1.0
% VO, set
mV
% VO, set
mV
% VO, set
B, A, F, G
Y, M, P, S1R0
B, A, F, G
Y, M, P, S1R0
All
B
30
mVrms
B
100
mVpk-pk
RMS (5Hz to 20MHz bandwidth)
All, except B
25
mVrms
Peak-to-Peak (5Hz to 20MHz bandwidth)
All, except B
75
mVpk-pk
Peak-to-Peak (5Hz to 20MHz bandwidth)
External Capacitance
Output Current
Output Current Limit Inception (Hiccup Mode )
(VO= 90% of VO, set)
Output Short-Circuit Current
(VO≤250mV) ( Hiccup Mode )
Efficiency
B
CO, max
0
1,500
μF
A
F, G, Y, M, P,
S1R0
B
CO, max
0
10,000
μF
CO, max
0*
20,000
μF
Io
0
10
Adc
A
Io
0
20
Adc
F
Io
0
30
Adc
G
Io
0
35
Adc
Y, M, P, S1R0
Io
0
40
All, except G
G
IO, lim
IO, lim
105
103
115
115
130
130
Adc
% Io
% Io
All
IO, s/c
130
150
Arms
B
η
93.0
VIN= VIN, nom, TA=25°C
A
η
91.7
%
IO=IO, max , VO= VO,set
F
η
92.0
%
G
η
89.8
%
Y
η
88.3
%
M
η
87.1
%
%
Switching Frequency
%
P
η
85.0
S1R0
η
83.2
%
All
fsw
420
kHz
* Note: For 1.0VO (S1R0) and 1.2 VO (P) device codes, external capacitance, CO, should be 1000uF minimum to achieve monotonic start-up with very light load
(≤ 2Amp).
October 1, 2015
©2012 General Electric Company. All rights reserved.
Page 3
GE
Data Sheet
EQW010-040 Series (Eighth-Brick) DC-DC Converter Power Modules
36–75Vdc Input; 1.0 to 12.0Vdc Output; 10 to 40A Output Current
Electrical Specifications (continued)
Parameter
Device
Symbol
Min
All
Vpk
All
ts
All
Vpk
All
ts
Typ
Max
Unit
3
% VO, set
200
s
5
% VO, set
200
s
Dynamic Load Response
(dIo/dt=0.1A/s; VIN = VIN, nom; TA=25°C)
Load Change from Io= 50% to 75% or 25% to
50% of Io,max;
Peak Deviation