Technical catalogue
Modular DIN rail components
Installation contactors
Installation Contactors
Overview...................................................................................................................................... 2
ESB Installation Contactors
20 A / AC-1/AC-7a
ESB20 .................................................................................................... 4
24 A / AC-1/AC-7a
ESB24 .................................................................................................... 5
40 A / AC-1/AC-7a
ESB40 .................................................................................................... 6
63 A / AC-1/AC-7a
ESB63 .................................................................................................... 7
Main Technical Data ................................................................................................................... 8
Lighting application .................................................................................................................. 13
EN Installation Contactors - Manually/Automatic Operated
20 A / AC-1/AC-7a
EN20 ................................................................................................... 14
24 A / AC-1/AC-7a
EN24 .................................................................................................... 15
40 A / AC-1/AC-7a
EN40 .................................................................................................... 16
Main Technical Data ................................................................................................................. 17
ESB/EN Installation Contactors
Main Accessories ..................................................................................................................... 19
1SBC103011S0201
Index .......................................................................................................................................... 20
ABB | 1
Modular DIN rail components
Installation Contactors ESB and EN
All over the world, commercial and industrial buildings such
as hospitals, hotels, shopping and sport centers, domestic
and residential installation are equipped with ABB low voltage
products and systems.
From switchboard to light switch, ABB covers the complete
range of equipment required for controlling and protecting
electrical installations.
Typical segments
1-2 Residential installations | 3 Hotels
1
2 | ABB
2
3
For controlling and remote switching, ABB offers a complete range
of installation contactors that are mainly used in the following
applications:
s Lighting
s Heating
s Ventilation
s Pumps and motors.
ESB and EN installation contactors are designed to match the
Modular DIN rail components for common use in dedicated panels.
The ESB range includes 4 ratings from 20 A to 63 A with
2 to 4-pole version.
The EN range includes 3 ratings from 20 A to 40 A.
Many contacts variations are available for managing all application.
Products comply with standards IEC60947-4-1 and IEC61095.
Construction:
The ESB20, EN20 operates with an AC solenoid system.
Types ESB24...63, EN24...40 are fitted with a DC solenoid actuator
and are therefore hum-free. The noise during switching is barely
audible making it beneficial for use in buildings such as hospitals,
hotels or houses. An incorporated varistor protects the coil against
remote lightning strikes and overvoltages up to 5 kV.
In addition, it limits the interference voltage peaks of the solenoid
system.
The contactors can therefore be combined with programmable
logic controllers. There is no need for a protective circuit. The
solenoid system is provided with radio interference suppression.
Accessories are available, such as auxiliary contacts and sealing
covers.
ESB advantages:
s Powerful for lamp switching
s Operation flag indicator
s DC coil: - Noiseless and hum free
- Low power consumption
- Integrated overvoltage protection.
The EN contactors have a built-in toggle switch for automatic and
manual operation.
EN advantages:
s Facilitate commissioning
s Functional test before start-up
s Ease maintenance operation
s High degree of safety and availability in case of automation
system failure.
4 Shopping centers | 5 Hospitals | 6 Commercial & industrial buildings
4
5
6
ABB | 3
20 A
AC-1/AC-7a
ESB20 Installation Contactors
AC Operated
Application
Certifications and Approvals
The ESB contactors are used mainly in buildings for
switching and controlling lighting, heating, ventilation and
pumps. They are part of the complete range of Din rail
products and can be integrated easily in dedicated panels.
UL
CSA
CCC
RMRS
CE
BV
Description
The ESB20 contactors are used for the control of single phase loads up to 20 A.
They operate with an AC coil.
You can choose between a various N.O. and N.C. contacts combination.
Ordering Details
Main poles
A1
1
3
A2
2
4
Nb of
Control coil voltage
modules 50 Hz
60 Hz
Type
Order code
Pack(ing) Weight
pieces kg (1 pce)
1
ESB20-20
GHE3211102R1004
GHE3211102R1005
GHE3211102R0001
GHE3211102R0002
GHE3211102R0003
GHE3211102R0004
GHE3211102R0006
GHE3211102R0005
GHE3211102R0007
GHE3211202R1004
GHE3211202R1005
GHE3211202R0001
GHE3211202R0002
GHE3211202R0003
GHE3211202R0004
GHE3211202R0006
GHE3211202R0005
GHE3211202R0007
GHE3211302R1004
GHE3211302R1005
GHE3211302R0001
GHE3211302R0002
GHE3211302R0003
GHE3211302R0004
GHE3211302R0006
GHE3211302R0005
GHE3211302R0007
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
12 V
20 V
24 V
42 V
48 V
110 V
230 V
240 V
400 V
12 V
20 V
24 V
42 V
48 V
110 V
230 V
240 V
400 V
12 V
20 V
24 V
42 V
48 V
110 V
230 V
240 V
400 V
2 N.O.
A1
R1
R3
A2
R2
R4
1
2 N.C.
A1
1
R3
A2
2
R4
1
1 N.O.
1 N.C.
14 V
24 V
28 V
48 V
55 V
125...127 V
264 V
278 V
14 V
24 V
28 V
48 V
55 V
125...127 V
264 V
278 V
14 V
24 V
28 V
48 V
55 V
125...127 V
264 V
278 V
-
ESB20-02
ESB20-11
Main Technical Data
Main poles
acc to. IEC 60947-4-1
and IEC 61095
Magnet system
Connecting
capacity
Mounting positions
Pos. 2
+30°
0.14
0.14
0.14
0.14
0.14
0.14
0.14
0.14
0.14
0.14
0.14
0.14
0.14
0.14
0.14
0.14
0.14
0.14
0.14
0.14
0.14
0.14
0.14
0.14
0.14
0.14
0.14
For complete technical data see 1SBC103005S0201.pdf
Rated operational voltage Ue
Ie AC-1 / AC-7a Rated operational current (for air temperature close to contactor θ ≤ 55 °C)
AC-3 / AC-7b Ratings (for air temperature close to contactor θ ≤ 55 °C)
Rated operational power
1 phase
230 V
1 phase
Ie Rated operational current
230 V
Coil operating limits (acc. to IEC 60947-4-1)
Average pull-in coil consumption value
Average holding coil consumption value
Main pole terminals
Rigid
Coil terminals
Rigid
-30°
59 2.32"
250 V
20 A
1.1 kW
9A
0.85 … 1.1 Uc (at θ ≤ 55 °C)
8 VA / 5 W
3.2 VA / 1.2 W
1 x 1.5 … 10 mm2
2 x 1.5 … 4 mm2
1 x 0.5 … 4 mm2
2 x 0.75 … 2.5 mm2
17.5 0.69"
Pos. 4
Pos. 3
6.8 0.68"
4 | ABB
43.5 1.71"
Dimensions: mm, inches
1SBC103001S0201
85 3.35"
35 mm
EN/IEC 60175
45 1.77"
Pos. 1, 3, 4, 1± 30°
1.1 0.43"
Pos. 1
24 A
AC-1/AC-7a
ESB24 Installation Contactors
AC / DC Operated
Application
Certifications and Approvals
The ESB contactors are used mainly in buildings for switching and controlling lighting, heating, ventilation and pumps.
They are part of the complete range of Din rail products and
can be integrated easily in dedicated panels.
UL
CSA
CCC
RMRS
BV
GL
LRS
CE
DNV
Description
The ESB24 contactors are used for the control of single and three-phases loads up to 24 A.
Due to their DC solenoid actuator, the ESB24 can be connected to AC or DC voltages.
This provides the following benefits:
Hum-free operating system, no vibration, silent in operation, low power consumption, integrated high overvoltage
protection 5 kV. You can choose between a various N.O. and N.C. contacts combination.
Main accessories:
Auxiliary contact blocks EH04.
Ordering Details
Main poles
A1
1
3
5
7
A2
2
4
6
8
Nb of
Control coil voltage
modules 40... 450 Hz
DC
2
12 V
12 V
24 V
24 V
42 V
42 V
48 V
48 V
110...120 V
110...120 V
230...240 V
230...240 V
400...415 V
400...415 V
2
12 V
12 V
24 V
24 V
42 V
42 V
48 V
48 V
110...120 V
110...120 V
230...240 V
230...240 V
400...415 V
400...415 V
2
12 V
12 V
24 V
24 V
42 V
42 V
48 V
48 V
110...120 V
110...120 V
230...240 V
230...240 V
400...415 V
400...415 V
2
12 V
12 V
24 V
24 V
42 V
42 V
48 V
48 V
110...120 V
110...120 V
230...240 V
230...240 V
400 ...415 V
400 ...415 V
2
12 V
12 V
24 V
24 V
42 V
42 V
48 V
48 V
110...120 V
110...120 V
230...240 V
230...240 V
400 ... 415 V 400 ... 415 V
4 N.O.
A1
R1
R3
R5
R7
A2
R2
R4
R6
R8
4 N.C.
A1
1
R3
R5
7
A2
2
R4
R6
8
2 N.O.
2 N.C.
A1
1
R3
5
7
A2
2
R4
6
8
3 N.O.
1 N.C.
A1
R1
3
R5
R7
A2
R2
4
R6
R8
1 N.O.
3 N.C.
Type
Order code
ESB24-40
GHE3291102R1004
GHE3291102R0001
GHE3291102R0002
GHE3291102R0003
GHE3291102R0004
GHE3291102R0006
GHE3291102R0007
GHE3291202R1004
GHE3291202R0001
GHE3291202R0002
GHE3291202R0003
GHE3291202R0004
GHE3291202R0006
GHE3291202R0007
GHE3291302R1004
GHE3291302R0001
GHE3291302R0002
GHE3291302R0003
GHE3291302R0004
GHE3291302R0006
GHE3291302R0007
GHE3291602R1004
GHE3291602R0001
GHE3291602R0002
GHE3291602R0003
GHE3291602R0004
GHE3291602R0006
GHE3291602R0007
GHE3291702R1004
GHE3291702R0001
GHE3291702R0002
GHE3291702R0003
GHE3291702R0004
GHE3291702R0006
GHE3291702R0007
ESB24-04
ESB24-22
ESB24-31
ESB24-13
Main Technical Data
Main poles
acc to. IEC 60947-4-1
and IEC 61095
Magnet system
Connecting
capacity
Mounting positions
Pos. 2
+30°
Pack(ing)
pieces
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
Weight
kg (1 pce)
0.28
0.28
0.28
0.28
0.28
0.28
0.28
0.28
0.28
0.28
0.28
0.28
0.28
0.28
0.28
0.28
0.28
0.28
0.28
0.28
0.28
0.28
0.28
0.28
0.28
0.28
0.28
0.28
0.28
0.28
0.28
0.28
0.28
0.28
0.28
For complete technical data see 1SBC103005S0201.pdf
Rated operational voltage Ue
Ie AC-1 / AC-7a Rated operational current (for air temperature close to contactor θ ≤ 55 °C)
AC-3 / AC-7b Ratings (for air temperature close to contactor θ ≤ 55 °C)
Rated operational power
3 phases
400 V
3 phases
Ie Rated operational current
400 V
Coil operating limits (acc. to IEC 60947-4-1)
Average pull-in coil consumption value
Average holding coil consumption value
Main pole terminals
Rigid
Coil terminals
Rigid
400 V
24 A
4 kW
9A
0.85 … 1.1 Uc (at θ ≤ 55 °C)
4 VA / 4 W
4 VA / 4 W
1 x 1.5 … 10 mm2
2 x 1.5 … 4 mm2
1 x 1 … 4 mm2
2 x 0.75 … 2.5 mm2
-30°
59 2.32"
36 1.42"
Pos. 4
Pos. 3
Pos. 5
6.8 0.68"
43.5 1.71"
Dimensions: mm, inches
ABB | 5
1SBC103002S0201
1.1 0.43"
Pos. 1, 3, 4, 1± 30°
90 3.54"
45 1.77"
35 mm
EN/IEC 60175
Pos. 1
40 A
AC-1/AC-7a
ESB40 Installation Contactors
AC / DC Operated
Application
Certifications and Approvals
The ESB contactors are used mainly in buildings for switching and controlling lighting, heating, ventilation and pumps.
They are part of the complete range of Din rail products and
can be integrated easily in dedicated panels.
UL
CSA
RMRS
CCC
BV
GL
LRS
CE
DNV
Description
The ESB40 contactors are used for the control of single and three-phases loads up to 40 A.
Due to their DC solenoid actuator, the ESB40 can be connected to AC or DC voltages.
This provides the following benefits:
Hum-free operating system, no vibration, silent in operation, low power consumption, integrated high overvoltage
protection 5 kV. You can choose between a various N.O. and N.C. contacts combination.
Main accessories:
Auxiliary contact blocks EH04.
Ordering Details
Main poles
A1
1
3
5
7
A2
2
4
6
8
4 N.O.
A1
1
R3
R5
7
A2
2
R4
R6
8
GHE3491102R1004
GHE3491102R0001
GHE3491102R0002
GHE3491102R0003
GHE3491102R0004
GHE3491102R0006
GHE3491102R0007
GHE3491102R0008
GHE3491302R0001
GHE3491302R0006
Pack(ing)
pieces
3
3
3
3
3
3
3
3
3
3
Weight
kg (1 pce)
0.40
0.40
0.40
0.40
0.40
0.40
0.40
0.40
0.40
0.40
ESB40-31
GHE3491602R0001
GHE3491602R0006
3
3
0.40
0.40
24 V
230 V
400 V
ESB40-30
GHE3491502R0001
GHE3491502R0006
GHE3491502R0007
3
3
3
0.39
0.39
0.39
24 V
230 V
ESB40-20
GHE3491402R0001
GHE3491402R0006
3
3
0.38
0.38
Nb of
Control coil voltage
modules 40... 450 Hz DC
3
12 V
12 V
24 V
24 V
42 V
42 V
48 V
48 V
110...120 V
110...120 V
230...240 V
230...240 V
400...415 V
400...415 V
415 V
415 V
3
24 V
24 V
230 V
230 V
Type
Order code
ESB40-40
3
24 V
230 V
24 V
230 V
3
24 V
230 V
400 V
3
24 V
230 V
ESB40-22
2 N.O.
2 N.C.
A1
1
R3
5
7
A2
2
R4
6
8
3 N.O.
1 N.C.
A1
1
3
5
A2
2
4
6
3 N.O.
A1
1
3
A2
2
4
2 N.O.
Main Technical Data
Main poles
acc to. IEC 60947-4-1
and IEC 61095
For complete technical data see 1SBC103005S0201.pdf
Rated operational voltage Ue
400 V
Ie AC-1 / AC-7a Rated operational current (for air temperature close to contactor θ ≤ 55 °C) 40 A
AC-3 / AC-7b Ratings (for 1500 r.p.m., 50 Hz or 1800 r.p.m., 60 Hz, 3-phase motors)
(for air temperature close to contactor θ ≤ 55 °C)
Rated operational power
3 phases
Ie Max. Rated operational current 3 phases
Coil operating limits (acc. to IEC 60947-4-1)
Average pull-in coil consumption value
Average holding coil consumption value
Main pole terminals
Rigid
Magnet system
Connecting
capacity
Mounting positions
Pos. 2
+30°
Coil terminals
Rigid
-30°
59 2.32"
400 V
400 V
11 kW
22 A
0.85 … 1.1 Uc (at θ ≤ 55 °C)
5 VA / 5 W
5 VA / 5 W
1 x 1.5 … 25 mm2
2 x 1.5 … 10 mm2
1 x 1 … 4 mm2
2 x 0.75 … 2.5 mm2
54 2.13"
Pos. 4
Pos. 3
Pos. 5
6 | ABB
6.8 0.68"
43.5 1.71"
Dimensions: mm, inches
1SBC103003S0201
90 3.54"
35 mm
EN/IEC 60175
45 1.77"
Pos. 1, 3, 4, 1 ± 30°
1.1 0.43"
Pos. 1
63 A
AC-1/AC-7a
ESB63 Installation Contactors
AC / DC Operated
Application
Certifications and Approvals
The ESB contactors are used mainly in buildings for switching and controlling lighting, heating, ventilation and pumps.
They are part of the complete range of Din rail products and
can be integrated easily in dedicated panels.
UL
CSA
RMRS
CCC
BV
GL
LRS
CE
DNV
Description
The ESB63 contactors are used for the control of single and three-phases loads up to 63 A.
Due to their DC solenoid actuator, the ESB63 can be connected to AC or DC voltages.
This provides the following benefits:
Hum-free operating system, no vibration, silent in operation, low power consumption, integrated high overvoltage
protection 5 kV. You can choose between a various N.O. and N.C. contacts combination.
Main accessories:
Auxiliary contact blocks EH04.
Ordering Details
Main poles
A1
1
3
5
7
A2
2
4
6
8
4 N.O.
A1
1
R3
R5
7
A2
2
R4
R6
8
2 N.O.
GHE3691102R1004
GHE3691102R0001
GHE3691102R0002
GHE3691102R0003
GHE3691102R0004
GHE3691102R0006
GHE3691102R0007
GHE3691102R0008
GHE3691302R0007
Pack(ing)
pieces
3
3
3
3
3
3
3
3
3
Weight
kg (1 pce)
0.42
0.42
0.42
0.42
0.42
0.42
0.42
0.42
0.42
ESB63-31
GHE3691602R0004
GHE3691602R0006
3
3
0.42
0.42
230 V
400 V
ESB63-30
GHE3691502R0006
GHE3691502R0007
3
3
0.41
0.41
24 V
230 V
24 V
230 V
ESB63-20
GHE3691402R0001
GHE3691402R0006
3
3
0.40
0.40
230 V
230 V
ESB63-11
GHE3691802R0006
3
0.40
Nb of
Control coil voltage
modules 40... 450 Hz DC
3
12 V
12 V
24 V
24 V
42 V
42 V
48 V
48 V
110...120 V
110...120 V
230...240 V
230...240 V
400...415 V
400...415 V
415 V
415 V
3
400 V
400 V
Type
Order code
ESB63-40
3
110 V
230 V
110 V
230 V
3
230 V
400 V
3
3
ESB63-22
2 N.C.
A1
1
R3
A2
2
R4
3 N.O.
5
7
6
8
1 N.C.
A1
1
3
5
A2
2
4
6
3 N.O.
A1
1
3
A2
2
4
2 N.O.
A1
1
R3
A2
2
R4
1 N.O.
1 N.C.
Main Technical Data
Main poles
acc to. IEC 60947-4-1
and IEC 61095
For complete technical data see 1SBC103005S0201.pdf
Rated operational voltage Ue
400 V
Ie AC-1 / AC-7a Rated operational current (for air temperature close to contactor θ ≤ 55 °C) 63 A
AC-3 / AC-7b Ratings (for 1500 r.p.m., 50 Hz or 1800 r.p.m., 60 Hz, 3-phase motors)
(for air temperature close to contactor θ ≤ 55 °C)
Rated operational power
3 phases
Ie Max. rated operational current 3 phases
Coil operating limits (acc. to IEC 60947-4-1)
Average pull-in coil consumption value
Average holding coil consumption value
Main pole terminals
Rigid
Magnet system
Connecting
capacity
Mounting positions
Pos. 2
+30°
Coil terminals
Rigid
-30°
59 2.32"
400 V
400 V
15 kW
30 A
0.85 … 1.1 Uc (at θ ≤ 55 °C)
65 VA / 65 W
4.2 VA / 4.2 W
1 x 1.5 … 25 mm2
2 x 1.5 … 10 mm2
1 x 1 … 4 mm2
2 x 0.75 … 2.5 mm2
54 2.13"
Pos. 4
Pos. 3
Pos. 5
6.8 0.68"
43.5 1.71"
Dimensions: mm, inches
ABB | 7
1SBC103004S0201
90 3.54"
35 mm
EN/IEC 60175
45 1.77"
Pos. 1, 3, 4, 1 ± 30°
1.1 0.43"
Pos. 1
ESB Installation Contactors
Technical Data
Main Pole - Utilization Characteristics according to IEC
Contactor types:
AC operated
AC / DC operated
Rated operational voltage Ue max.
Rated frequency limits
Utilization category AC-1 / AC-7a
V
Hz
ESB20
ESB24
ESB40
ESB63
AC: 250, DC: 220
50/60, DC
AC: 400, DC: 220
20
20
24
24
40
30
63
30
9
-
9
9
22
22
30
30
1.1
10 x Ie / AC-3
8 x Ie / AC-3
1.3
4
3.7
11
5
15
20
35
63
80
72
1
3
176
4
240
6
150000
500000
150000
170000
150000
240000
for air temperature close to contactor < 55 °C
300
600
150000
150000
1
U
U
U
U
Max. rated operational current Ie AC-1 / AC-7a
N.O.
A
N.C.
A
Utilization category AC-3 / AC-7b
for air temperature close to contactor < 55 °C
Max. rated operational current Ie AC-3/AC-7b
A
230 V - 1 phase N.O.
A
400 V - 3 phases N.O.
Rated operational power AC-3
230 V - 1 phase
kW
400 V - 3 phases
kW
Rated making capacity AC-3
Rated breaking capacity AC-3
Short-circuit protection for contactors
gG type fuse
A
Rated short-time withstand current Icw
at 40 °C ambient temp.,
in free air, from a cold state
10 s
A
W
Heat dissipation per pole Ie / AC-1/AC-7a
Max. electrical switching frequency
– for AC-1 / AC-7a
cycles/h
– for AC-3 / AC-7b
cycles/h
Electrical durability
– for AC-1 / AC-7a
cycles
– for AC-3 / AC-7b
cycles
Mechanical durability
– millions of operating cycles
Single-phase (AC-1, AC-7a)
Three-phase (AC-1, AC-7a)
L1
L1
U
L2
U
V
M
M
Single-phase (AC-7b)
8 | ABB
V
L3
Three-phase (AC-7b, AC-3)
W
1SBC103005S0201
L2
ESB Installation Contactors
Technical Data
Main Pole - Utilization Characteristics according to UL/CSA
Contactor types:
AC operated
AC / DC operated
General use rating
Amp rating
ESB20
ESB24
ESB40
ESB63
240 V
480 V
A
A
20
-
24
40
63
120 V - 1 phase
240 V - 1 phase N.O.
N.C.
440 - 480 V - 3 phases N.O.
N.C.
A
A
A
A
A
9.8
9.8
8
-
9.6
9.6
7.6
3.4
22
22
21
-
28
30
21
-
120 V - 1 phase
240 V - 1 phase
440 - 480 V - 3 phases
hp
hp
hp
1/2
1
-
3
5
7.5
15
10
15
25
-
25 / K5
-
40 / K5
-
75 / K5
-
Motor rating
Amp rating
Motor power
Short-circuit protection for contactors without thermal
O/L relay - Motor protection excluded
Fuse rating, 480 V
Fuse type, 600 V
Max. electrical switching frequency
– for general use
– for motor use
A
cycles/h
cycles/h
300
600
General Technical Data
Rated insulation voltage Ui
according to IEC 60947-4-1
according to UL/CSA
Rated impulse withstand voltage Uimp
Standards
Air temperature close to contactor
– for operation at 0.85 ... 1.1 Uc
– for storage
Climatic withstand
Operating altitude
Shock withstand
Mounting positions
Pos 1, 3, 4, 1±30 °
Pos 5 : not allowed for ESB20
V
V
kV
400
500
240
600
6
IEC 60947-4-1 / EN 60947-4-1 and IEC 61095 / EN 61095, UL 508, CSA C22.2 N°14-05
°C
°C
-25 ... +55 (Type ESB24...63: for ambient temperature > 40 °C, add ESB-DIS (1/2 module) at every second contactor)
-40 ... +80
IEC 60068-2-30, UTE 63-100 execution 1*
≤ 2000
10 g / 4 ms / axes X Y Z
m
Pos. 2
+30°
-30°
Pos. 4
Pos. 3
Pos. 1
Fixing
on rail acc. to IEC 60715 and EN 60715
35 x 7.5
Pos. 1/3/4/1± 30°
Pos. 5
35 x 15
1SBC103005S0201
* ESB20 only
ABB | 9
ESB Installation Contactors
Technical Data
Magnet System Characteristics
Contactor types:
AC operated
AC / DC operated
Rated operational voltage Ue max.
- at 50 Hz
V
- at 60 Hz
V
- at 400 Hz
V
DC
V
Coil operating limits acc. to IEC 60947-4-1
Drop-out voltage in % of Uc
Frequency range
Hz
Coil consumption
VA / W
Average pull-in value
Average holding value
VA / W
Operating time
between coil energization and:
– N.O. contact closing
ms
between coil de-energization and:
– N.O. contact opening
ms
ESB20
ESB24
ESB40
ESB63
12 ... 400
12 ... 415
14 ... 380
12 ... 415
12 ... 415
12 ... 415
0.85 ... 1.1 x Uc (at θ ≤ 55 °C)
approx. 20 ... 75 %
approx. 10 ... 75 %
50/60
DC, 50 ... 400
24 ... 415
24 ... 415
24 ... 415
24 ... 415
8/5
3.2 / 1.2
4/4
4/4
5/5
5/5
65 / 65
4.2 / 4.2
12
40
12
40
ESB24
ESB40
ESB63
16-8
1.5 ... 25
1.5 ... 10
16-4
Connecting Characteristics
Contactor types:
AC operated
AC / DC operated
Connecting capacity (min. ... max.)
Main pole terminals
Rigid
Capacity acc. to UL/CSA
Coil terminals
Rigid
Capacity acc. to UL/CSA
Degree of protection
ESB20
1 x mm²
2 x mm²
AWG
1.5 ... 10
1.5 ... 4
14-8
1 x mm²
2 x mm²
AWG
0.5 ... 4
0.75 ... 2.5
18-14
1 ... 4
16-10
acc. to IEC 60947-1 / EN 60947-1 and IEC 60529 / EN 60529
Protection against direct contact in acc. with EN 50274
IP20
Flat Ø 5 / Pozidriv 1
Flat Ø 5 / Pozidriv 1
Flat Ø 7.5 / Pozidriv 2
Flat Ø 5 / Pozidriv 1
mm
mm
10
7
13
Nm
Nm
1.2
0.9
1
2.5
1SBC103005S0201
All terminals
Screwdriver type
Main poles
Coil terminals
Stripping length
Main poles
Coil terminals
Tightening torque
Main poles
Coil terminals
10 | ABB
ESB Installation Contactors
Technical Data
EH04... Auxiliary Contact Block - Utilization Characteristics according to IEC
Contactor types:
AC operated
AC / DC operated
Rated operational voltage Ue max.
Conventional free air thermal current Ith
θ < 40 °C
Rated frequency limits
Rated operational current Ie / AC-15
acc. to IEC 60947-5-1
240 V 50/60 Hz
415 V 50/60 Hz
500 V 50/60 Hz
acc. to IEC 60947-5-1
Making capacity
Breaking capacity acc. to IEC 60947-5-1
Short-circuit protection gI type fuse
Minimum switching capacity
with failure rate acc. to IEC 60947-5-4
Heat dissipation per pole at 6 A
ESB20
ESB24
ESB40
V
-
500
A
Hz
-
6
50/60
A
A
A
A
-
4
3
2
11 x Ie AC-15
11 x Ie AC-15
10
V/mA
W
-
17 / 5
0.1
ESB63
Electrical durability
AC-1 / 400 V / 3-phase for ESB20...63
1,5 2
ESB63
ESB24
1
ESB40
ESB20
Millions of operating cycles
2
1
0.8
0.6
0.5
0.4
0.3
0.2
0.1
0.08
0.06
0.05
0.04
0.03
0.02
0.01
AC-3 / 400 V / 3-phase for ESB24...63
Breaking current [A]
3
4 5 6
8 10
16 20 24 30 40 50 63 80
ESB63
ESB40
ESB24
Millions of operating cycles
2
1
0.8
0.6
0.5
0.4
0.3
0.2
0.1
0.08
0.06
0.05
0.04
0.03
0.02
Breaking current [A]
Switching capacity [kW]
0.01
1.5 2
3
1.1
4 5 6
8 10
2.2 3 4
16
7.5 11
24 30 40 50 63 80
1SBC103005S0201
1
15
ABB | 11
ESB Installation Contactors
Technical Data
DC-1/DC-3 switching DC with N.O. contacts (N.O.)
Type
Rated operating
voltage Ue
DC-1 (L/R ≤ 1 ms)
1 current path
2 current paths 3 current paths
in series
in series
DC-3 (L/R ≤ 2 ms)
1 current path 2 current paths 3 current paths
in series
in series
ESB20-20
24 V DC
48 V DC
60 V DC
110 V DC
220 V DC
24 V DC
48 V DC
60 V DC
110 V DC
220 V DC
24 V DC
48 V DC
60 V DC
110 V DC
220 V DC
24 V DC
48 V DC
60 V DC
110 V DC
220 V DC
20 A
15 A
15 A
5A
0.5 A
24.0 A
21.0 A
17.0 A
7.0 A
0.9 A
40.0 A
23.0 A
18.0 A
8.0 A
1.0 A
50.0 A
25.0 A
20.0 A
9.0 A
1.1 A
15 A
7A
5A
1.5 A
0.2 A
16.0 A
8.0 A
4.0 A
1.6 A
0.2 A
19.0 A
10.0 A
5.0 A
1.8 A
0.3 A
21.0 A
11.0 A
5.5 A
2.0 A
0.3 A
ESB24
ESB40
ESB63
20 A
20 A
20 A
15 A
5A
24.0 A
24.0 A
24.0 A
16.0 A
4.5 A
40.0 A
40.0 A
32.0 A
17.0 A
5.0 A
63.0 A
43.0 A
35.0 A
19.0 A
5.5 A
24.0 A
24.0 A
24.0 A
24.0 A
13.0 A
40.0 A
40.0 A
40.0 A
30.0 A
15.0 A
63.0 A
63.0 A
60.0 A
33.0 A
17.0 A
20 A
15 A
10 A
5A
1.5 A
24.0 A
18.0 A
14.0 A
6.5 A
1.0 A
40.0 A
20.0 A
16.0 A
7.0 A
1.1 A
44.0 A
22.0 A
18.0 A
8.0 A
1.2 A
24.0 A
24.0 A
24.0 A
16.0 A
4.0 A
40.0 A
40.0 A
34.0 A
18.0 A
4.5 A
63.0 A
47.0 A
38.0 A
21.0 A
5.0 A
DC-1/DC-3 switching DC with N.C. contacts (N.C.)
Type
Rated operating
voltage Ue
DC-1 (L/R ≤ 1 ms)
1 current path
2 current paths 3 current paths
in series
in series
DC-3 (L/R ≤ 2 ms)
1 current path 2 current paths 3 current paths
in series
in series
ESB20-02
24 V DC
48 V DC
60 V DC
110 V DC
220 V DC
24 V DC
48 V DC
60 V DC
110 V DC
220 V DC
14 A
7A
4.5 A
1.5 A
0.2 A
14.5 A
7.5 A
4.5 A
1.6 A
0.2 A
6A
3A
2A
0.6 A
0.1 A
6.3 A
3.1 A
2.0 A
0.7 A
0.1 A
24.0 A
22.0 A
17.5 A
9.5 A
3.8 A
10 A
6A
4A
1.8 A
0.6 A
11.0 A
5.4 A
4.3 A
1.9 A
0.6 A
19.0 A
9.4 A
7.5 A
4.1 A
1.6 A
1SBC103005S0201
ESB24
20 A
14 A
10 A
4.4 A
1.5 A
24.0 A
12.5 A
10.0 A
4.4 A
1.4 A
12 | ABB
ESB Installation Contactors - Lighting Application
Technical Data
Switching of lamp load
The following table shows the number of lamps which can be connected per phase at 230 V, 50 Hz. Air temperature, near the contactor, must be
limited to 55 °C.
Please, note that the given capacitor load must not be exceeded, otherwise inadmissible high inrush current peaks could occur.
These are influenced by the length and cross section of the wire used, the type of power supply unit and specifications of the lamp brand.
For these reasons, values in the table are for information only.
Numbers are given for a 230 V voltage distributed between phase and neutral: single phase (phase + neutral) or three-phases (3 phases + neutral),
lamps are wired in star connection.
In the case of three-phase supply without neutral, 230 V phase-to-phase, the permissible number of lamps per phase will be that given in the table
multiplied by 0.58.
Lamp type
Incandescent
lamps
Fluorescent lamps
Uncompensated
and series
compensation
Two-lamp circuit
Parallel
compensation
High pressure
mercury-vapor
lamps
Uncompensated
Parallel
compensation
Lamps with
electronic power
supply units
Lamp data
Permissible number
of lamps per phase
(230 V, 50 Hz )
Watt
60
100
200
300
500
1000
15
20
40
42
58
65
115
140
2 x 20
2 x 40
2 x 42
2 x 58
2 x 65
2 x 115
2 x 140
15
20
40
42
58
65
115
140
50
80
125
250
400
700
1000
2000/
400 V
50
80
125
250
400
700
1000
2000/
400 V
1 x 18
2 x 18
1 x 36
2 x 36
1 x 58
2 x 58
Capacitor
In
A
0.26
0.43
0.87
1.30
2.17
4.35
0.33
0.37
0.43
0.54
0.64
0.67
1.3
1.5
2 x 0.13
2 x 0.22
2 x 0.24
2 x 0.34
2 x 0.34
2 x 0.65
2 x 0.75
0.11
0.13
0.22
0.24
0.34
0.34
0.65
0.75
0.61
0.8
1.15
2.15
3.25
5.40
7.5
8
ESB20
ESB24
ESB40
ESB63
μF
21
13
7
4
3
1
40
37
32
26
21
21
9
9
2 x 22
2 x 17
2 x 13
2 x 10
2 x 10
2x4
2x4
16
16
16
13
11
11
4
4
30
15
10
6
2
2
1
–
25
15
7
5
3
1
30
26
20
16
12
12
5
5
2 x 26
2 x 20
2 x 16
2 x 12
2 x 12
2x5
2x5
8
8
8
6
5
5
2
2
14
10
7
4
2
1
1
1
54
32
16
11
6
3
100
85
65
52
40
40
18
18
2 x 85
2 x 65
2 x 52
2 x 40
2 x 40
2 x 18
2 x 18
16
16
16
12
10
10
4
4
36
27
19
10
7
4
3
3
83
50
25
16
10
5
155
135
105
85
65
65
28
28
2 x 140
2 x 105
2 x 65
2 x 65
2 x 65
2 x 28
2 x 28
67
67
67
50
43
43
17
17
50
38
26
14
10
6
4
4
0.28
0.41
0.65
1.22
1.95
3.45
4.8
5.45
4
3
2
1
–
–
–
–
5
4
3
2
1
–
–
1
10
8
6
3
3
1
1
2
43
37
26
15
10
5
4
3
–
–
–
–
–
–
15
8
12
7
11
6
24
18
16
11
14
8
55
34
34
20
32
17
76
48
47
29
46
24
4.5
4.5
4.5
6
7
7
18
18
7
8
10
18
25
45
60
35
Lamp type
Lamp data
Permissible number
of lamps per phase
(230 V, 50 Hz )
Watt
ESB20
ESB24
ESB40
ESB63
9
4
3
1
1
–
–
–
–
10
5
3
2
1
–
–
–
–
28
14
8
5
4
1
1
2
1
38
20
11
7
6
2
1
2
1
–
–
–
–
–
–
–
–
–
5
3
1
1
–
–
–
–
–
11
5
3
2
2
–
–
1
–
30
18
9
7
6
2
1
2
1
In
A
0.53
1
1.8
3
3.5
9.5
16.5
10.5
18
35
Halogen
metal-vapor lamps 70
150
Uncompensated
250
400
1000
2000
2000/
3500/
400 V
35
0.25
Parallel
70
0.45
compensation
150
0.75
250
1.5
400
2.5
1000
5.8
2000
11.5
2000/
6.6
3500/
11.6
400 V
35
1.5
Low pressure
55
1.5
sodium-vapor
90
2.4
lamps
135
3.5
Uncompensated
150
3.3
180
3.3
200
2.3
35
0.31
Parallel
55
0.42
compensation
90
0.63
135
0.94
150
1.0
180
1.16
200
1.32
150
1.8
High pressure
250
3.0
sodium-vapor
330
3.7
lamps
400
4.7
Uncompensated
1000
10.3
150
0.83
Parallel
250
1.5
compensation
330
2.0
400
2.4
1000
6.3
Transformers
Transformers
for halogen
for Watt
low voltage lamps 20
(12 or 24 V AC)
50
75
100
150
200
300
Capacitor
μF
6
12
20
33
35
95
148
58
100
10
8
22
30
10
8
22
30
5
5
13
19
3
3
10
13
3
3
10
14
3
3
10
14
3
5
14
20
1
4
15
20
1
4
15
20
1
3
10
30
2
7
45
2
8
40
2
8
40
1
3
12
25
3
4
15
20
2
3
9
15
1
2
8
10
1
6
8
3
4
1
3
15
20
1
2
9
33
2
7
40
1
6
48
2
106
Permissible number of transformers per circuit
(230 V, 50 Hz)
40
50
110
174
20
24
50
80
13
16
35
54
10
12
27
43
7
9
19
29
5
6
14
23
3
4
9
14
L1
L1
230 V
N
L3
N
Single-phase
Three-phase
Three-phase with neutral 400 V
1SBC103007S0201
230 V
230 V
230 V
L3
230 V
L2
L1
230 V
230 V
L2
ABB | 13
20 A
AC-1/AC-7a
EN20 Installation Contactors - Manually / Automatic Operated
AC Operated
Application
Certifications and Approvals
The EN contactors are used mainly in buildings for switching
and controlling lighting, heating, ventilation and pumps.
They are part of the complete range of Din rail products and
can be integrated easily in dedicated panels.
UL
CSA
CE
CCC
Description
The EN20 contactors are used for the control of single phase loads up to 20 A. They operate with an AC coil.
EN contactors have a built-in toggle switch to select between three function modes:
Off position, automatic run (normal contactor function), manual override with a return to Auto the next time the coil is
energized.
This offers many advantages as:
You can make functional test before installation start-up. It can be used for maintenance operation, to change lamps
and test it. It provides higher safety and drop out as you can switch the application manually.
The toggle switch is also used for household application like water heating where double tariff of kWh is used.
Ordering Details
1
Main poles
3
0 = Off
A1
0
1
3
A2
2
4
Type
Order code
Pack(ing) Weight
pieces kg (1 pce)
1
EN20-20
GHE3221101R0001
GHE3221101R0006
10
10
24 V
230 V
28 V
264 V
0.14
0.14
2 N.O.
S
T
0
P
A
U
T
O
A1
Nb of
Control coil voltage
modules 50 Hz
60 Hz
Automatic
run
M
A
N
1
2
I = ON
2
4
Main Technical Data
Main poles
acc to. IEC 60947-4-1
and IEC 61095
Magnet system
Connecting
capacity
Coil terminals
Mounting positions
Pos. 2
+30°
For complete technical data see 1SBC103005S0201.pdf
Rated operational voltage Ue
Ie AC-1 / AC-7a Rated operational current (for air temperature close to contactor θ ≤ 55 °C)
230 V
Pe AC-1 Rated operational power
Coil operating limits (acc. to IEC 60947-4-1)
Average pull-in coil consumption value
Average holding coil consumption value
Main pole terminals
Rigid
Rigid
-30°
58 2.28"
250 V
20 A
4 kW
0.85 … 1.1 Uc (at θ ≤ 55 °C)
8 VA / 5 W
3.2 VA / 1.2 W
1 x 1.5 … 10 mm2
2 x 1.5 … 4 mm2
1 x 0.5 … 4 mm2
2 x 0.75 … 2.5 mm2
17.5 0.69"
Pos. 4
Pos. 3
6.8 0.68"
14 | ABB
43.5 1.71"
Dimensions: mm, inches
1SBC103008S0201
85 3.35"
35 mm
EN/IEC 60175
45 1.77"
Pos. 1, 3, 4, 1± 30°
1.1 0.43"
Pos. 1
24 A
AC-1/AC-7a
EN24 Installation Contactors - Manually / Automatic Operated
AC / DC Operated
Application
Certifications and Approvals
The EN contactors are used mainly in buildings for switching
and controlling lighting, heating, ventilation and pumps.
They are part of the complete range of Din rail products and
can be integrated easily in dedicated panels.
UL
CSA
CE
CCC
Description
The EN24 contactors are used for the control of single and three-phase loads up to 24 A. They operate with a DC coil.
EN contactors have a built-in toggle switch to select between three function modes:
Off position, automatic run (normal contactor function), manual Override with a return to Auto the next time the coil is
energized.
This offers many advantages as:
You can make functional test before installation start-up, it can be used for maintenance operation, to change lamps
and test it, it provide higher safety and drop out as you can switch the application manually.
The toggle switch is also used for household application like water heating where double tariff of kWh is used.
Ordering Details
1
Main poles
3
0 = Off
A1
0
5
7
A2
2
4
6
8
Pack(ing) Weight
pieces kg (1 pce)
2
24 V
230/240 V
24 V
230/240 V
EN24-40
GHE3261101R0001
GHE3261101R0006
5
5
0.24
0.24
A1
1
R3
5
7
2
24 V
230/240 V
24 V
230/240 V
EN24-31
GHE3261601R0001
GHE3261601R0006
5
5
0.24
0.24
A2
2
R4
6
8
2
230/240 V
230/240 V
EN24-30
GHE3261501R0006
5
0.23
3 N.O.
1 N.C.
2
I = ON
2
3
Order code
Automatic
run
M
A
N
1
1
Type
4 N.O.
S
T
0
P
A
U
T
O
A1
Nb of
Control coil voltage
modules 40...450 Hz
DC
A1
1
3
5
A2
2
4
6
3 N.O.
4
Main Technical Data
Main poles
acc to. IEC 60947-4-1
and IEC 61095
Magnet system
Connecting
capacity
Mounting positions
Pos. 2
+30°
For complete technical data see 1SBC103005S0201.pdf
Rated operational voltage Ue
400 V
Ie AC-1 / AC-7a Rated operational current (for air temperature close to contactor θ ≤ 55 °C) 24 A
230 V
Pe AC-1 Rated operational power
5.3 kW
400 V
16 kW
Coil operating limits (acc. to IEC 60947-4-1)
0.85 … 1.1 Uc (at θ ≤ 55 °C)
Average pull-in coil consumption value
4 VA / 4 W
Average holding coil consumption value
4 VA / 4 W
Main pole terminals
Rigid
1 x 1.5 … 10 mm2
2 x 1.5 … 4 mm2
Coil terminals
Rigid
1 x 1 … 4 mm2
2 x 0.75 … 2.5 mm2
-30°
36 1.42"
58 2.28"
Pos. 4
Pos. 3
Pos. 5
6.8 0.68"
43.5 1.71"
Dimensions: mm, inches
ABB | 15
1SBC103009S0201
85 3.35"
35 mm
EN/IEC 60175
45 1.77"
Pos. 1, 3, 4, 1 ± 30°
1.1 0.43"
Pos. 1
40 A
AC-1/AC-7a
EN40 Installation Contactors - Manually / Automatic Operated
AC / DC Operated
Application
Certifications and Approvals
The EN contactors are used mainly in buildings for switching and controlling lighting, heating, ventilation and pumps.
They are part of the complete range of Din rail products
and can be integrated easily in dedicated panels.
UL
CSA
CE
CCC
Description
The EN40 contactors are used for the control of single and three-phase loads up to 40 A. They operate with a DC coil.
EN contactors have a built-in toggle switch to select between three function modes:
Off position, automatic run (normal contactor function), manual Override with a return to Auto the next time the coil is
energized.
This offers many advantages as:
You can make functional test before installation start-up, it can be used for maintenance operation, to change lamps
and test it, it provide higher safety and drop out as you can switch the application manually.
The toggle switch is also used for household application like water heating where double tariff of kWh is used.
Ordering Details
1
Main poles
3
0 = Off
A1
0
5
7
A2
2
4
6
8
Pack(ing) Weight
pieces kg (1 pce)
3
24 V
110 V
230/240 V
24 V
110 V
230/240 V
EN40-40
GHE3421101R0001
GHE3421101R0004
GHE3421101R0006
3
3
3
0.41
0.41
0.41
A1
1
R3
5
7
3
24 V
230/240 V
24 V
230/240 V
EN40-31
GHE3421601R0001
GHE3421601R0006
3
3
0.41
0.41
A2
2
R4
6
8
3
230/240 V
230/240 V
EN40-30
GHE3421501R0006
3
0.40
3
230/240 V
230/240 V
EN40-20
GHE3421401R0006
3
0.30
3 N.O.
1 N.C.
2
I = ON
2
3
Order code
Automatic
run
M
A
N
1
1
Type
4 N.O.
S
T
0
P
A
U
T
O
A1
Nb of
Control coil voltage
modules 40...450 Hz
DC
A1
1
3
5
A2
2
4
6
3 N.O.
4
A1
1
3
A2
2
4
2 N.O.
Main Technical Data
Main poles
acc to. IEC 60947-4-1
and IEC 61095
Magnet system
Connecting
capacity
Mounting positions
Pos. 2
+30°
-30°
For complete technical data see 1SBC103005S0201.pdf
Rated operational voltage Ue
400 V
Ie AC-1 / AC-7a Rated operational current (for air temperature close to contactor θ ≤ 55 °C) 40 A
230 V
Pe AC-1 Rated operational power
8.8 kW
400 V
26 kW
Coil operating limits (acc. to IEC 60947-4-1)
0.85 … 1.1 Uc (at θ ≤ 55 °C)
Average pull-in coil consumption value
5 VA / 5 W
Average holding coil consumption value
5 VA / 5 W
Main pole terminals
Rigid
1 x 1.5 … 25 mm2
2 x 1.5 … 10 mm2
Coil terminals
Rigid
1 x 1 … 4 mm2
2 x 0.75 … 2.5 mm2
54 2.13"
58 2.28"
Pos. 4
Pos. 3
Pos. 5
6.8 0.68"
16 | ABB
43.5 1.71"
Dimensions: mm, inches
1SBC103012S0201
85 3.35"
35 mm
EN/IEC 60175
45 1.77"
Pos. 1, 3, 4, 1± 30°
1.1 0.43"
Pos. 1
EN Installation Contactors - Manually / Automatic Operated
Technical Data
Main Pole - Utilization Characteristics according to IEC
Contactor types:
AC operated
AC / DC operated
Rated operational voltage Ue max.
Rated frequency limits
Utilization category AC-1 / AC-7a
V
Hz
EN20
EN24
EN40
250
50/60
400
A
A
20
-
24
24
40
30
A
20
35
63
10 s
A
Heat dissipation per pole Ie / AC-1 / AC-7a
W
Max. electrical switching frequency
– for AC-1 / AC-7a
cycles/h
Electrical Durability
– for AC-1 / AC-7a
cycles
Mechanical durability
– millions of operating cycles
72
1
for air temperature close to contactor < 55 °C
Max. rated operational current Ie AC-1 / AC-7a
N.O.
N.C.
Short-circuit protection
for contactors gG type fuse
Rated short-time withstand current Icw
at 40 °C ambient temp.,
in free air, from a cold state
176
4
300
150000
1
General Technical Data
Contactor types:
AC operated
AC / DC operated
Rated insulation voltage Ui
according to IEC 60947-4-1
Rated impulse withstand voltage Uimp.
Standards
Air temperature close to contactor
– for operation at 0.85 ... 1.1 Uc
– for storage
Climatic withstand
Operating altitude
Shock withstand
Mounting positions
Pos 1, 3, 4, 1±30 °
Pos 5 : not allowed for EN20
EN20
EN24
EN40
V
kV
400
500
6
IEC 60947-4-1 / EN 60947-4-1 and IEC 61095 / EN 61095
°C
°C
-25 ... +55 (Type EN24...40: for ambient temperature > 40 °C, add ESB-DIS (1/2 module) at every second contactor)
-40 ... +80
IEC 60068-2-30, UTE 63-100 execution 1*
≤ 2000
10 g / 4 ms / axes X Y Z
m
Pos. 2
+30°
-30°
Pos. 4
Pos. 3
Pos. 1
Fixing
on rail acc. to IEC 60715 and EN 60715
Pos. 1/3/4/1± 30°
Pos. 5
35 mm
1SBC103014S0201
* EN20 only
ABB | 17
EN Installation Contactors - Manually / Automatic Operated
Technical Data
Magnet System Characteristics
Contactor types:
AC operated
AC / DC operated
Rated operational voltage Ue max.
- at 50 Hz
V
- at 60 Hz
V
V DC
Coil operating limits acc. to IEC 60947-4-1
Drop-out voltage in % of Uc
Frequency range
Hz
Coil consumption
Average pull-in value
VA / W
Average holding value
VA / W
Operating time
between coil energization and:
– N.O. contact closing
ms
between coil de-energization and:
– N.O. contact opening
ms
EN20
EN24
EN40
12 ... 415
12 ... 415
12 ... 415
24 ... 415
24 ... 415
24 ... 415
12 ... 400
14 ... 380
0.85 ... 1.1 x Uc (at θ ≤ 55 °C)
approx. 20 ... 75 %
50/60
approx. 10 ... 75 %
40 ... 450
8/5
3.2 / 1.2
4/4
4/4
12
40
12
40
5/5
5/5
Connecting Characteristics
EN20
Contactor types:
Connecting capacity (min. ... max.)
Main pole terminals
Rigid
Capacity acc. to UL/CSA
Coil terminals
Rigid
Capacity acc. to UL/CSA
Degree of protection
1 x mm²
2 x mm²
AWG
1.5 ... 10
1.5 ... 4
14 ... 8
1 x mm²
2 x mm²
AWG
0.5 ... 4
0.75 ... 2.5
18 ... 14
EN24
EN40
16 ... 8
1.5 ... 25
1.5 ... 10
16 ... 4
1 ... 4
16 ... 10
acc. to IEC 60947-1 / EN 60947-1 and IEC 60529 / EN 60529
Protection against direct contact in acc. with EN 50274
IP20
Flat Ø 5 / Pozidriv 1
Flat Ø 5 / Pozidriv 1
Flat Ø 7.5 / Pozidriv 2
Flat Ø 5 / Pozidriv 1
mm
mm
10
7
13
Nm
Nm
1.2
0.9
1
2.5
1SBC103014S0201
All terminals
Screwdriver type
Main poles
Coil terminals
Stripping length
Main poles
Coil terminals
Tightening torque
Main poles
Coil terminals
18 | ABB
ESB, EN Installation Contactors
Main Accessories
Ordering Details
Auxiliary Contact Blocks
Type
Order code
Pack(ing) Weight
pieces kg (1 pce)
EH04-20
EH04-11
GHE3401321R0001
GHE3401321R0002
10
10
Contactor
type
Type
Order code
Pack(ing) Weight
pieces kg (1 pce)
ESB24, EN24
ESB40...63, EN40
ESB-PLK24
GHE3201903R0001
ESB-PLK40/63 GHE3401903R0002
10
10
Contactor
type
Type
Order code
Pack(ing) Weight
pieces kg (1 pce)
ESB24...63, EN24...40
ESB-DIS
GHE3201902R0001
10
Contactor type
ESB20...63, EN20...40
Type
Order code
Pack(ing) Weight
pieces kg (1 pce)
Label - unlabelled*
Label - numbering 1-40
Label - numbering 2 * 1-20
Label - numbering 4 * 1-10
Label - numbering 4 * 11-20
Label - labelled L1
Label - labelled L2
Label - labelled L3
SZ-KZS
SZ-KZS/1
SZ-KZS/6
SZ-KZS/9
SZ-KZS/10
SZ-KZS/11
SZ-KZS/12
SZ-KZS/13
GHS2101946R0004
GHS2101946R0005
GHS2101946R0010
GHS2101946R0013
GHS2101946R0014
GHS2101946R0015
GHS2101946R0016
GHS2101946R0017
30
30
30
30
30
30
30
30
Contactor
type
Sealing cover
ESB-PLK40/63
Contact blocks
ESB24...63
EN24...40
ESB-PLK24
2
1
1
0.004
0.004
Sealing cover
0.002
0.009
Auxiliary Contact Blocks
Distance piece
0.002
Labelling material
ESB24-40
EH04-20
Contact Blocks
EH04-20
EH04-11
Distance piece
0.008
0.008
0.008
0.008
0.008
0.008
0.008
0.008
Note: * The unlabelled can be labelled by water-resistant and permanent marker or by means of computer-controlled
labelling system (plotter).
Special labels on request: minimum quantities 50
Labelling material
ESB-DIS
1SBC103006S0201
SZ-KZS...
ABB | 19
Index
Order codes
Order code
Type
Order code
Type
Order code
Type
GHE3201902R0001
ESB-DIS
Page
19
GHE3291302R0004
ESB24-22
Page
5
GHE3691302R0007
ESB63-22
Page
7
GHE3201903R0001
ESB-PLK24
19
GHE3291302R0006
ESB24-22
5
GHE3691402R0001
ESB63-20
7
GHE3211102R0001
ESB20-20
4
GHE3291302R0007
ESB24-22
5
GHE3691402R0006
ESB63-20
7
GHE3211102R0002
ESB20-20
4
GHE3291302R1004
ESB24-22
5
GHE3691502R0006
ESB63-30
7
GHE3211102R0003
ESB20-20
4
GHE3291602R0001
ESB24-31
5
GHE3691502R0007
ESB63-30
7
GHE3211102R0004
ESB20-20
4
GHE3291602R0002
ESB24-31
5
GHE3691602R0004
ESB63-31
7
GHE3211102R0005
ESB20-20
4
GHE3291602R0003
ESB24-31
5
GHE3691602R0006
ESB63-31
7
GHE3211102R0006
ESB20-20
4
GHE3291602R0004
ESB24-31
5
GHE3691802R0006
ESB63-11
GHE3211102R0007
ESB20-20
4
GHE3291602R0006
ESB24-31
5
GHS2101946R0004
SZ-KZS
19
GHE3211102R1004
ESB20-20
4
GHE3291602R0007
ESB24-31
5
GHS2101946R0005
SZ-KZS/1
19
19
7
GHE3211102R1005
ESB20-20
4
GHE3291602R1004
ESB24-31
5
GHS2101946R0010
SZ-KZS/6
GHE3211202R0001
ESB20-02
4
GHE3291702R0001
ESB24-13
5
GHS2101946R0013
SZ-KZS/9
19
GHE3211202R0002
ESB20-02
4
GHE3291702R0002
ESB24-13
5
GHS2101946R0014
SZ-KZS/10
19
GHE3211202R0003
ESB20-02
4
GHE3291702R0003
ESB24-13
5
GHS2101946R0015
SZ-KZS/11
19
GHE3211202R0004
ESB20-02
4
GHE3291702R0004
ESB24-13
5
GHS2101946R0016
SZ-KZS/12
19
GHE3211202R0005
ESB20-02
4
GHE3291702R0006
ESB24-13
5
GHS2101946R0017
SZ-KZS/13
19
GHE3211202R0006
ESB20-02
4
GHE3291702R0007
ESB24-13
5
GHE3211202R0007
ESB20-02
4
GHE3291702R1004
ESB24-13
5
GHE3211202R1004
ESB20-02
4
GHE3401321R0001
EH04-20
19
GHE3211202R1005
ESB20-02
4
GHE3401321R0002
EH04-11
19
GHE3211302R0001
ESB20-11
4
GHE3401903R0002
ESB-PLK40/63
19
GHE3211302R0002
ESB20-11
4
GHE3421101R0001
EN40-40
16
GHE3211302R0003
ESB20-11
4
GHE3421101R0004
EN40-40
16
GHE3211302R0004
ESB20-11
4
GHE3421101R0006
EN40-40
16
GHE3211302R0005
ESB20-11
4
GHE3421401R0006
EN40-20
16
GHE3211302R0006
ESB20-11
4
GHE3421501R0006
EN40-30
16
GHE3211302R0007
ESB20-11
4
GHE3421601R0001
EN40-31
16
GHE3211302R1004
ESB20-11
4
GHE3421601R0006
EN40-31
16
GHE3211302R1005
ESB20-11
4
GHE3491102R0001
ESB40-40
6
GHE3221101R0001
EN20-20
14
GHE3491102R0002
ESB40-40
6
GHE3221101R0006
EN20-20
14
GHE3491102R0003
ESB40-40
6
GHE3261101R0001
EN24-40
15
GHE3491102R0004
ESB40-40
6
GHE3261101R0006
EN24-40
15
GHE3491102R0006
ESB40-40
6
GHE3261501R0006
EN24-30
15
GHE3491102R0007
ESB40-40
6
GHE3261601R0001
EN24-31
15
GHE3491102R0008
ESB40-40
6
GHE3261601R0006
EN24-31
15
GHE3491102R1004
ESB40-40
6
GHE3291102R0001
ESB24-40
5
GHE3491302R0001
ESB40-22
6
GHE3291102R0002
ESB24-40
5
GHE3491302R0006
ESB40-22
6
GHE3291102R0003
ESB24-40
5
GHE3491402R0001
ESB40-20
6
GHE3291102R0004
ESB24-40
5
GHE3491402R0006
ESB40-20
6
GHE3291102R0006
ESB24-40
5
GHE3491502R0001
ESB40-30
6
GHE3291102R0007
ESB24-40
5
GHE3491502R0006
ESB40-30
6
GHE3291102R1004
ESB24-40
5
GHE3491502R0007
ESB40-30
6
GHE3291202R0001
ESB24-04
5
GHE3491602R0001
ESB40-31
6
GHE3291202R0002
ESB24-04
5
GHE3491602R0006
ESB40-31
6
GHE3291202R0003
ESB24-04
5
GHE3691102R0001
ESB63-40
7
GHE3291202R0004
ESB24-04
5
GHE3691102R0002
ESB63-40
7
GHE3291202R0006
ESB24-04
5
GHE3691102R0003
ESB63-40
7
GHE3291202R0007
ESB24-04
5
GHE3691102R0004
ESB63-40
7
GHE3291202R1004
ESB24-04
5
GHE3691102R0006
ESB63-40
7
GHE3291302R0001
ESB24-22
5
GHE3691102R0007
ESB63-40
7
GHE3291302R0002
ESB24-22
5
GHE3691102R0008
ESB63-40
7
GHE3291302R0003
ESB24-22
5
GHE3691102R1004
ESB63-40
7
20 | ABB
Index
Types
Type
Order code
EH04-11
GHE3401321R0002
Page
19
GHE3291702R0004
5
GHE3691102R0004
EH04-20
GHE3401321R0001
19
GHE3291702R0006
5
GHE3691102R0006
7
EN20-20
GHE3221101R0001
14
GHE3291702R0007
5
GHE3691102R0007
7
7
GHE3221101R0006
14
EN24-30
GHE3261501R0006
15
EN24-31
GHE3261601R0001
EN24-40
Type
Order code
Page
Type
Order code
Page
7
GHE3291702R1004
5
GHE3691102R0008
GHE3291302R0001
5
GHE3691102R1004
7
15
GHE3291302R0002
5
ESB-DIS
GHE3201902R0001
19
GHE3261601R0006
15
GHE3291302R0003
5
ESB-PLK24
GHE3201903R0001
19
GHE3261101R0001
15
GHE3291302R0004
5
ESB-PLK40/63
GHE3401903R0002
19
GHE3261101R0006
15
GHE3291302R0006
5
SZ-KZS
GHS2101946R0004
19
EN40-20
GHE3421401R0006
16
GHE3291302R0007
5
SZ-KZS/1
GHS2101946R0005
19
EN40-30
GHE3421501R0006
16
GHE3291302R1004
5
SZ-KZS/6
GHS2101946R0010
19
EN40-31
GHE3421601R0001
16
GHE3291602R0001
5
SZ-KZS/9
GHS2101946R0013
19
19
EN40-40
ESB20-02
ESB20-11
ESB20-20
ESB24-04
ESB24-13
ESB24-22
ESB24-31
GHE3421601R0006
16
GHE3291602R0002
5
SZ-KZS/10
GHS2101946R0014
GHE3421101R0001
16
GHE3291602R0003
5
SZ-KZS/11
GHS2101946R0015
19
GHE3421101R0004
16
GHE3291602R0004
5
SZ-KZS/12
GHS2101946R0016
19
GHE3421101R0006
16
GHE3291602R0006
5
SZ-KZS/13
GHS2101946R0017
19
GHE3211202R0001
4
GHE3291602R0007
5
GHE3211202R0002
4
GHE3291602R1004
5
GHE3211202R0003
4
GHE3291102R0001
5
GHE3211202R0004
4
GHE3291102R0002
5
GHE3211202R0005
4
GHE3291102R0003
5
GHE3211202R0006
4
GHE3291102R0004
5
5
ESB24-40
GHE3211202R0007
4
GHE3291102R0006
GHE3211202R1004
4
GHE3291102R0007
5
GHE3211202R1005
4
GHE3291102R1004
5
GHE3211302R0001
4
GHE3211302R0002
4
ESB40-20
ESB40-22
GHE3491402R0001
6
GHE3491402R0006
6
GHE3211302R0003
4
GHE3211302R0004
4
GHE3211302R0005
4
GHE3211302R0006
4
GHE3491502R0006
6
GHE3211302R0007
4
GHE3491502R0007
6
GHE3211302R1004
4
GHE3491602R0001
6
GHE3211302R1005
4
GHE3211102R0001
4
ESB40-30
ESB40-31
ESB40-40
GHE3491302R0001
6
GHE3491302R0006
6
GHE3491502R0001
6
GHE3491602R0006
6
GHE3491102R0001
6
GHE3211102R0002
4
GHE3491102R0002
6
GHE3211102R0003
4
GHE3491102R0003
6
GHE3211102R0004
4
GHE3491102R0004
6
GHE3211102R0005
4
GHE3491102R0006
6
GHE3211102R0006
4
GHE3491102R0007
6
GHE3211102R0007
4
GHE3491102R0008
6
GHE3211102R1004
4
GHE3491102R1004
6
GHE3211102R1005
4
ESB63-11
GHE3691802R0006
7
GHE3291202R0001
5
ESB63-20
GHE3691402R0001
7
GHE3291202R0002
5
GHE3291202R0003
5
ESB63-22
GHE3291202R0004
5
ESB63-30
GHE3291202R0006
5
GHE3291202R0007
5
GHE3291202R1004
5
ESB63-31
GHE3691402R0006
7
GHE3691302R0007
7
GHE3691502R0006
7
GHE3691502R0007
7
GHE3691602R0004
7
GHE3691602R0006
7
GHE3291702R0001
5
GHE3691102R0001
7
GHE3291702R0002
5
GHE3691102R0002
7
GHE3291702R0003
5
GHE3691102R0003
7
ESB63-40
ABB | 21
ABB France
Low Voltage Products Division
10, rue Ampère Z.I. - B.P. 114
F-69685 Chassieu cedex / France
ABB STOTZ-KONTAKT GmbH
Eppelheimer Straße 82
D-69123 Heidelberg / Germany
Note:
We reserve the right to make technical changes or
modify the contents of this document without prior
notice. With regard to purchase orders, the agreed
particulars shall prevail. ABB does not accept any
responsibility whatsoever for potential errors or possible lack of information in this document.
We reserve all rights in this document and in the
subject matter and illustrations contained therein.
Any reproduction, disclosure to third parties or
utilization of its contents – in whole or in parts – is
forbidden without prior written consent of ABB.
Copyright© 2011 ABB
All rights reserved
You can find the address of your local sales organisation
on the ABB home page
http://www.abb.com/contacts -> Low Voltage products
www.abb.com/lowvoltage
1SBC 103 001 C0202 - Printed in France (W 10.2011 Ferréol)
Contact us