GE
Data Sheet
ESTW010A0A Series (Eighth-Brick) DC-DC Converter Power Modules
36–75Vdc Input; 5.0Vdc Output; 10A Output Current
STINGRAY™ SERIES
RoHS Compliant
Applications
Features
Wide input voltage range: 36-75 Vdc
Monotonic startup into prebiased load
Output Voltage adjust: 80% to 110% of Vo,nom
Remote sense
Constant switching frequency
Positive remote On/Off logic
Input under/over voltage protection
Output overcurrent and overvoltage protection
Over-temperature protection
Industry standard, DOSA compliant footprint
57.9mm x 22.8mm x 8.5mm
(2.28 in x 0.9 in x 0.335 in)
Distributed Power Architectures
Low profile height and reduced component skyline
Wireless Networks
Access and Optical Network Equipment
Suitable for cold wall cooling using suitable Gap Pad applied
directly to top side of module
Industrial Equipment
High efficiency: 91%
No thermal derating up to 80 °C, 1.0m/s (200 LFM)
Wide operating temperature range (-40°C to 85°C)
Compliant to RoHS EU Directive 2011/65/EU & REACH
Directive (EC) No. 1907/2006
UL* 60950-1, 2nd Ed. Recognized, CSA† C22.2 No. 60950 107 Certified, and VDE‡ (EN60950-1, 2nd Ed.) Licensed
CE mark meets 2014/35/EU directive§
Meets the voltage and current requirements for ETSI 300132-2 and complies with and licensed for Basic insulation
rating per EN60950-1
2250 Vdc Isolation tested in compliance with IEEE 802.3¤
PoE standards
ISO**9001 and ISO 14001 certified manufacturing facilities
Options
Negative Remote On/Off logic (preferred)
Over current/Over temperature/Over voltage protections
(Auto-restart) (preferred)
Heat plate version (-H)
RoHS 6/6 compliant; Lead Free (-Z)
For additional options, see Table 2 (Device Options)
under “Ordering Information” section.
Description
The ESTW010A0A, Eighth-brick low-height power module is an isolated dc-dc converter that can deliver up to 10A of output
current and provide a precisely regulated output voltage of 5.0V over a wide range of input voltages (VIN = 36 - 75Vdc). The
modules achieve typical full load efficiency of 91%. The open frame modules construction, available in through-hole packaging,
enable designers to develop cost and space efficient solutions.
* UL is a registered trademark of Underwriters Laboratories, Inc.
† CSA is a registered trademark of Canadian Standards Association.
‡ VDE is a trademark of Verband Deutscher Elektrotechniker e.V.
§ This product is intended for integration into end-user equipment . All of the required procedures of end-use equipment should be followed.
¤ IEEE and 802 are registered trademarks of the Institute of Electrical and Electronics Engineers, Incorporated.
** ISO is a registered trademark of the International Organization of Standards
October 30, 2019
©2016 General Electric Company. All rights reserved.
GE
Data Sheet
ESTW010A0A Series Eighth-Brick Power Modules
36–75Vdc Input; 5.0Vdc Output; 10A Output Current
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress
ratings only, functional operation of the device is not implied at these or any other conditions in excess of those given in the
operations sections of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect the
device reliability.
Parameter
Device
Symbol
Min
Max
Unit
Input Voltage
Continuous
All
VIN
-0.3
80
Vdc
Transient, operational (≤100 ms)
All
VIN,trans
-0.3
100
Vdc
All
TA
-40
85
°C
Storage Temperature
All
Tstg
-55
125
°C
I/O Isolation voltage (100% factory Hi-Pot tested)
All
2250
Vdc
Operating Ambient Temperature
(see Thermal Considerations section)
Electrical Specifications
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions.
Parameter
Operating Input Voltage
Maximum Input Current
(VIN= VIN, min to VIN, max, IO=IO, max)
Input No Load Current
(VIN = 48V, IO = 0, module enabled)
Input Stand-by Current
Device
Symbol
Min
Typ
Max
Unit
All
VIN
36
48
75
Vdc
All
IIN,max
2.0
Adc
All
IIN,No load
30
IIN,stand-by
5
All
(VIN = 48V, module disabled)
I2t
mA
8
mA
0.5
A2s
Inrush Transient
All
Input Reflected Ripple Current, peak-to-peak
(5Hz to 20MHz, 1μH source impedance; VIN, min to VIN, max,
IO= IOmax ; See Test configuration section)
All
30
mAp-p
Input Ripple Rejection (120Hz)
All
50
dB
CAUTION: This power module is not internally fused. An input line fuse must always be used.
This power module can be used in a wide variety of applications, ranging from simple standalone operation to an integrated
part of sophisticated power architectures. To preserve maximum flexibility, internal fusing is not included, however, to
achieve maximum safety and system protection, always use an input line fuse. The safety agencies require a fast-acting
fuse with a maximum rating of 5 A (see Safety Considerations section). Based on the information provided in this data sheet
on inrush energy and maximum dc input current, the same type of fuse with a lower rating can be used. Refer to the fuse
manufacturer’s data sheet for further information.
October 30, 2019
©2016 General Electric Company. All rights reserved.
Page 2
GE
Data Sheet
ESTW010A0A Series Eighth-Brick Power Modules
36–75Vdc Input; 5.0Vdc Output; 10A Output Current
Electrical Specifications (continued)
Parameter
Device
Symbol
Min
Typ
Max
Unit
All
VO, set
4.925
5.0
5.075
Vdc
All
VO
4.90
5.10
Vdc
All
All
All
±0.2
±0.2
±1.0
% VO, set
% VO, set
% VO, set
All
25
50
mVrms
mVpk-pk
Nominal Output Voltage Set-point
VIN= 48V IO=IO, max, TA=25°C)
Output Voltage
(Over all operating input voltage, resistive load, and
temperature conditions until end of life)
Output Regulation
Line (VIN=VIN, min to VIN, max)
Load (IO=IO, min to IO, max)
Temperature (Tref=TA, min to TA, max)
Output Ripple and Noise
(Co=1uF,ceramic+10uF,tantalum, VIN=VIN, min to VIN, max,
IO= IO, max , TA=TA, min to TA, max)
RMS (5Hz to 20MHz bandwidth)
75
200
External Capacitance1
All
CO
0
2,000
μF
Output Current
Output Current Limit Inception (Hiccup Mode )
(VO= 90% of VO, set)
Output Short-Circuit Current
(VO≤250mV) ( Hiccup Mode )
Efficiency
All
Io
0
10
Adc
All
IO, lim
105
120
130
% Io
All
IO, s/c
1.2
All
η
91.0
%
All
fsw
350
kHz
All
Vpk
250
mV
All
ts
200
s
Device
Symbol
Min
Typ
Max
Unit
Isolation Capacitance
All
Ciso
1000
pF
Isolation Resistance
All
Riso
10
MΩ
I/O Isolation Voltage (100% factory Hi-pot tested)
All
All
2250
Vdc
Device
Typ
Max
Peak-to-Peak (5Hz to 20MHz bandwidth)
All
VIN=48V, TA=25°C, IO=IO, max , VO= VO,set
Switching Frequency
Dynamic Load Response
(Co=1uF,ceramic+10uF,tantalum, dIo/dt=0.1A/s; VIN
= 48V; TA=25°C)
Load Change from Io= 50% to 75% or 25% to 50% of
Io,max
Peak Deviation
Settling Time (Vo