FLT012A0-SZ

FLT012A0-SZ

  • 厂商:

    ABB

  • 封装:

  • 描述:

    DC INPUT FILTER MODULE

  • 数据手册
  • 价格&库存
FLT012A0-SZ 数据手册
GE Data Sheet FLT012A0Z/FLT012A0-SZ: Input Filter Modules 75Vdc Input Voltage Maximum; 12A Output Current Maximum Features ƒ Compliant to RoHS EU Directive Directive 2011/65/EU (Z versions) ƒ Compatible in a Pb-free or SnPb reflow environment (Z versions) ƒ Surface Mount and Through hole versions ƒ Common-mode and Differential-mode filtering ƒ Small size and low profile 48.3 mm x 25.4 mm x 11.7 mm (1.9 in x 1.0 in x 0.46 in) RoHS Compliant Applications ƒ Distributed power architectures ƒ Wireless Networks ƒ Enterprise Networks ƒ Access and Optical Network Equipment ƒ Same footprint as FLTR100V10 module ƒ Cost efficient open frame design ƒ Wide operating temperature range (-40°C to +85°C) ƒ Meets the voltage isolation requirements for ETSI 300-132-2 ƒ UL* 60950-1, 2nd Ed. Recognized, CSA† C22.2 No. 60950-107 Certified, and VDE‡(EN60950-1, 2nd Ed.) Licensed ƒ CE mark meets 2006/95/EC directives§ ƒ ISO** 9001 and ISO 14001 certified manufacturing facilities Options ƒ Surface Mount Interconnect (-S) Description The Filter module shall be designed to operate over an input voltage range up to 75Vdc at output current of 12A in an ambient temperature of -40ºC to 85ºC. The filter module shall be optimized for use with dc/dc converter modules, to significantly reduce the conducted differential and common-mode noise returned to the power source. The filter module shall enable designers to meet the requirements of EMI standards CISPR 22 (EN55022) and FCC Class B by inserting in-line between the power source and the dc/dc converter module. These modules shall be designed and manufactured to be either surface mounted(-S version) or through hole mounted on PCBs. * UL is a registered trademark of Underwriters Laboratories, Inc. † CSA is a registered trademark of Canadian Standards Association. ‡ VDE is a trademark of Verband Deutscher Elektrotechniker e.V. ** ISO is a registered trademark of the International Organization of Standards § This product is intended for integration into end-user equipment . All of the required procedures of end-use equipment should be followed. February 4, 2016 ©2016 General Electric Company. All rights reserved. GE Data Sheet FLT012A0Z/FLT012A0-SZ: Input Filter Modules 75Vdc Input Voltage Maximum; 12A Output Current Maximum Absolute Maximum Ratings Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings only, functional operation of the device is not implied at these or any other conditions in excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect the device reliability. Parameter Device Symbol Min Max Unit All VIN 0 75 Vdc Input Voltage Continuous VIN, TRANS 0 100 V Operating Ambient Temperature Transient (100ms) All TA -40 85 °C Storage Temperature All Tstg -55 125 °C FLT012A0Z / FLT012A0-SZ   1500 Vdc FLT012A0-11Z - - 2000 Vdc 10 - MŸ I/O to Ground Isolation (100% Factory Tested) Input to GND Insulation Electrical Specifications Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions. Parameter Device Symbol Min Typ Max Unit All VIN 0 24/48 75 Vdc (VIN= 0 to ViN,max) All Imax 12 Adc Resistance per leg All R 20 m: I max 12 A I max 8 A Operating Input Voltage Maximum Input-to-Output Current Maximum Average Current (TA = 60°C, 2.03 m/s (400lfm) air) Maximum Average Current (TA = 60°C, natural convection) CAUTION: This power module is not internally fused. An input line fuse must always be used. This power module can be used in a wide variety of applications, ranging from simple standalone operation to an integrated part of sophisticated power architecture. To preserve maximum flexibility, internal fusing is not included, however, to achieve maximum safety and system protection, always use an input line fuse. The safety agencies require a fast-acting fuse with a maximum rating of 15 A (see Safety Considerations section). Based on the information provided in this data sheet on inrush energy and maximum dc input current, the same type of fuse with a lower rating can be used. Refer to the fuse manufacturer’s data sheet for further information. February 4, 2016 ©2016 General Electric Company. All rights reserved. Page 2 GE Data Sheet FLT012A0Z/FLT012A0-SZ: Input Filter Modules 75Vdc Input Voltage Maximum; 12A Output Current Maximum Insertion Loss Tables – Standard Version Parameter Device Symbol Min Typ Max Unit Common-mode Insertion Loss 50: circuit, 500kHz All 41 45 dB 50: circuit, 1MHz All 51 56 dB 50: circuit, 10MHz All 69 75 dB 50: circuit, 500kHz All 50 55 dB 50: circuit, 1MHz All 52 57 dB 50: circuit, 10MHz All 48 53 dB Min Typ Differential-mode Insertion Loss Insertion Loss Tables – 11 version (2000V withstand) Parameter Device Symbol Max Unit Common-mode Insertion Loss 50: circuit, 500kHz All 42 45 dB 50: circuit, 1MHz All 52 56 dB 50: circuit, 10MHz All 70 75 dB 50: circuit, 500kHz All 51 55 dB 50: circuit, 1MHz All 53 57 dB 50: circuit, 10MHz All 49 53 dB Min Typ Differential-mode Insertion Loss General Specifications Parameter Calculated MTBF (VIN= VIN, nom, IO= 0.8IO, max, TA=40°C) Telecordia SR 332 Issue 2: Method 1, case 3 Weight February 4, 2016 Max 150,609,226  ©2016 General Electric Company. All rights reserved. 12 (0.42) Unit Hours  g (oz.) Page 3 GE Data Sheet FLT012A0Z/FLT012A0-SZ: Input Filter Modules 75Vdc Input Voltage Maximum; 12A Output Current Maximum Characteristic Curves The following figures provide typical characteristics for the FLT012A0 Module. 0 -10 -20 INSERTION LOSS (dB) INSERTION LOSS (dB) -30 -40 -50 -60 -70 -80 -90 -100 10 100k 1M FREQUENCY (MHz) 10M 30M FREQUENCY (MHz) Figure 1: Typical Common-Mode Insertion Loss in a 50: : circuit (Standard Version, 100MHz Axis max.) Figure 4.: Typical Differential-Mode Insertion Loss in a 50: : circuit.(-11 Option, 30MHz Axis max.) 0 -10 14 -20 12 OUTPUT CURRENT, Io (A) INSERTION LOSS (dB) -30 -40 -50 -60 -70 -80 -90 10 Natural Convection 00.5m/s / (100lfm) 8 6 1m/s (200lfm) 2m/s (400lfm) 4 2 0 -100 20 1 100k 1M 10M 30 40 50 60 70 80 90 30M FREQUENCY AMBIENT TEMPERATURE, TA OC Figure 2: Typical Common-Mode Insertion Loss in a 50: : circuit. (-11 Option, 30MHz Axis max.) Figure 5. Derating Output Current versus Local Ambient Temperature and Airflow. INSERTION LOSS (dB) INPUT 1 ame = 4 N 5 8 4 1 ame = 4 N 5 8 4 OUTPUT GROUND FREQUENCY (MHz) Figure 3: Typical Differential-Mode Insertion Loss in a 50: : circuit. (Standard Version, 100MHz Axis max.) February 4, 2016 Figure 6. Internal Schematic ©2016 General Electric Company. All rights reserved. Page 4 GE Data Sheet FLT012A0Z/FLT012A0-SZ: Input Filter Modules 75Vdc Input Voltage Maximum; 12A Output Current Maximum Application Guidelines Conducted noise on the input power lines can occur as either differential-mode or common-mode noise currents. Differential-mode noise is measured between the two input lines, and is found mostly at the low frequency end of the spectrum. This noise shows up as noise at the fundamental switching frequency and its harmonics. Common-mode noise is measured between the input lines and ground and is mostly broadband noise above 10 MHz. The highfrequency nature of common-mode noise is mostly due to the high-speed switching transitions of power train components. Either or both types of noise may be covered in a specification, as well as a combination of the two. Differential-mode noise is best attenuated using a filter composed of line-to-line capacitors (X caps) and series inductance, provided by either a discrete inductor or the leakage inductance of a common-mode choke. In addition to the differential filtering provided by the filter module, it is recommended that an electrolytic capacitor be located at the converter side of the filter to provide additional attenuation of low-frequency differential noise and to provide a low source impedance for the converter, preventing input filter oscillations and load transient induced input voltage dips. Open-frame DC/DC converter modules and the older metalcased DC/DC converter modules require slightly different filtering arrangements. The FLT012A0 series of modules are optimized for the newer open-frame series of modules, but can also be used with older metal-case modules. The main differences in filtering recommendations between the two types of modules are in common-mode filtering, as explained below. Filtering Open-Frame DC/DC Converter Modules For filtering open-frame DC/DC converter modules, the recommended circuit is shown in Fig. 7. In addition to the input electrolytic filter capacitor C1 (recommended value is a minimum of 100uF and approximately 1uF/W at power levels above 100W), common-mode filtering capacitors C2 and C3 should be connected between the input and outputs as shown. Suitable values for common-mode capacitors C2 and C3 are in the range between 1000pF to 0.1PF are usually indicated in the DC/DC converter data sheet. These capacitors need to be rated for the isolation voltage desired between the input and output sides of the DC/DC converter module. The recommended power layout of the modules showing where the two common-mode capacitors are to be placed is shown in Fig. 8. C2 VI(+) VI(+) FILTER MODULE VO(+) DC/DC CONVERTER MODULE C1 VI(-) VI(-) VO(-) CHASSIS GROUND C3 Figure 7. Schematic diagram showing recommended connection of the FLT012A0 filter module with openframe DC/DC converter modules. Load C2 Input VO+ PLANE VO+ VIN+ FLT012A0 MODULE VI+ VO+ DC/DC CONVERTER C1 GND VIN- VO- VI- VO- VO PLANE CHASSIS GROUND C3 Figure 8. Diagram showing recommended layout of the FLT012A0 filter module with open-frame DC/DC converter modules. Filtering Metal-Case DC/DC Converter Modules For metal-case DC/DC converter modules with a case pin, a different filtering arrangement and layout is recommended. Figure 9 shows the schematic diagram of the recommended circuit. The main difference with open-frame module is the use of an isolated shield plane located underneath the module which is connected through capacitors C2 through C5 to the input and output connections of the module. The shield plane along with the case of the module serves as a Faraday shield helping reduce EMI. The corresponding layout for metal-case modules is shown in Fig. 10. VI( +) VI(+) FILTER MODULE C1 VI( -) VO(+) DC/DC CONVERTER MODULE VI(-) VO(-) CASE CHASSIS GROUND C2 C3 C4 C5 SHIELD PLANE Figure 9. Schematic diagram showing recommended connection of the FLT012A0 filter module with metalcased DC/DC converter modules. February 4, 2016 ©2016 General Electric Company. All rights reserved. Page 5 GE Data Sheet FLT012A0Z/FLT012A0-SZ: Input Filter Modules 75Vdc Input Voltage Maximum; 12A Output Current Maximum Load Input C4 C2 VO+ VIN+ FLT012A0 MODULE VI+ VO+ DC/DC CONVERTER C1 GND CASE VI- VO VINCHASSIS GROUND SHIELD PLANE C3 VO- C5 Figure 10. Diagram showing recommended layout of the FLT012A0 filter module with metal-case DC/DC converter modules. Example Data Showing Results using the FLT012A0 Modules Figure 11 shows example results obtained using a QBVW033 DC/DC converter module with the FLT012A0 filter module. The QBVW033 module is operated at an input voltage of 48V and output loading corresponding to an input current of 8.7A, a level close to the 12A capability of the FLT012A0 filter module. Board capacitance was as per recommendations in the QBVW033 datasheet. The results show that the filter module is capable of meeting EN55022 Class A limits with 11 dB margin. Level [dBμV] 80 70 60 x + x + 50 x + + +xxx+x ++ 40 30 20 10 0 x + 150k MES MES MES MES 300k 500k 1M 2M Frequency [Hz] 3M 5M 7M 10M 30M CE1220111019_fin _ QP CE1220111019_fin _ AV CE1220111019_pre _p PK CE1220111019_pre AV Figure 11. Experimental results showing conducted EMI measured using a FLT012A0 module with a QBVW033 DC/DC converter. February 4, 2016 ©2016 General Electric Company. All rights reserved. Page 6 GE Data Sheet FLT012A0Z/FLT012A0-SZ: Input Filter Modules 75Vdc Input Voltage Maximum; 12A Output Current Maximum Thermal Considerations Power modules operate in a variety of thermal environments; however, sufficient cooling should always be provided to help ensure reliable operation. Considerations include ambient temperature, airflow, module power dissipation, and the need for increased reliability. A reduction in the operating temperature of the module will result in an increase in reliability. The thermal data presented here is based on physical measurements taken in a wind tunnel. The test set-up is shown in Fig. 12. Note that the airflow is parallel to the long axis of the module as shown in Fig. 12. Figure 13. Tref Temperature measurement location. 25.4_ (1.0) Wind Tunnel PWBs Power Module 76.2_ (3.0) x 12.7_ (0.50) Probe Location for measuring airflow and ambient temperature Air flow Figure 12. Thermal Test Set-up. The thermal reference point, Tref used in the specifications is shown in Figure 13. For reliable operation this temperature should not exceed 130oC. The output power of the module should not exceed the rated output current of the module. Please refer to the Application Note “Thermal Characterization Process For Open-Frame Board-Mounted Power Modules” for a detailed discussion of thermal aspects including maximum device temperatures. February 4, 2016 ©2016 General Electric Company. All rights reserved. Page 7 GE Data Sheet FLT012A0Z/FLT012A0-SZ: Input Filter Modules 75Vdc Input Voltage Maximum; 12A Output Current Maximum Pick and Place The FLT012A0-SR SMT modules use an open frame construction and are designed for a fully automated assembly process. The modules are fitted with a label designed to provide a large surface area for pick and place operations. The label meets all the requirements for surface mount processing, as well as safety standards, and is able to withstand reflow temperatures of up to 300oC. The label also carries product information such as product code, serial number and location of manufacture. Nozzle Recommendations The module weight has been kept to a minimum by using open frame construction. Even so, these modules have a relatively large mass when compared to conventional SMT components. Variables such as nozzle size, tip style, vacuum pressure and pick & placement speed should be considered to optimize this process. The minimum recommended nozzle diameter for reliable operation is 5 mm. The maximum nozzle outer diameter, which will safely fit within the allowable component spacing, is 8 mm max. time must be allowed to fuse the plating on the connection to ensure a reliable solder joint. There are several types of SMT reflow technologies currently used in the industry. These surface mount power modules can be reliably soldered using natural forced convection, IR (radiant infrared), or a combination of convection/IR. For reliable soldering the solder reflow profile should be established by accurately measuring the modules CP connector temperatures. REFLOW TEMP (qC) Surface Mount Information REFLOW TIME (S) MAX TEMP SOLDER (qC) Figure 15: Reflow Profile for Tin/Lead (Sn/Pb) process. Figure 14: Pick and Place Location. Bottom Side / First Side Assembly This module is not recommended for assembly on the bottom side of a customer board. If such an assembly is attempted, components may fall off the module during the second reflow process. Tin Lead Soldering The FLT012A0-SZ power modules are lead free modules and can be soldered either in a lead-free solder process or in a conventional Tin/Lead (Sn/Pb) process. It is recommended that the customer review data sheets in order to customize the solder reflow profile for each application board assembly. The following instructions must be observed when soldering these units. Failure to observe these instructions may result in the failure of or cause damage to the modules, and can adversely affect long-term reliability. In a conventional Tin/Lead (Sn/Pb) solder process peak reflow temperatures are limited to less than 235oC. Typically, the eutectic solder melts at 183oC, wets the land, and subsequently wicks the device connection. Sufficient February 4, 2016 Figure 16: Time Limit Curve Above 205oC Reflow for Tin Lead (Sn/Pb) process. Lead Free Soldering The FLT012A0-SZ SMT modules are lead-free (Pb-free) and RoHS compliant and are both forward and backward compatible in a Pb-free and a SnPb soldering process. Failure to observe the instructions below may result in the failure of or cause damage to the modules and can adversely affect long-term reliability. Pb-free Reflow Profile Power Systems will comply with J-STD-020 Rev. C (Moisture/Reflow Sensitivity Classification for Nonhermetic Solid State Surface Mount Devices) for both Pb-free solder profiles and MSL classification procedures. This standard provides a recommended forced-air-convection reflow profile based on the volume and thickness of the package ©2016 General Electric Company. All rights reserved. Page 8 GE Data Sheet FLT012A0Z/FLT012A0-SZ: Input Filter Modules 75Vdc Input Voltage Maximum; 12A Output Current Maximum (table 4-2). The suggested Pb-free solder paste is Sn/Ag/Cu (SAC). The recommended linear reflow profile using Sn/Ag/Cu solder is shown in Figure. 17. Soldering outside of the recommended profile requires testing to verify results and performance. MSL Rating The FLT012A0-SRZ SMT modules have a MSL rating of 2a. Storage and Handling The recommended storage environment and handling procedures for moisture-sensitive surface mount packages is detailed in J-STD-033 Rev. A (Handling, Packing, Shipping and Use of Moisture/Reflow Sensitive Surface Mount Devices). Moisture barrier bags (MBB) with desiccant are required for MSL ratings of 2 or greater. These sealed packages should not be broken until time of use. Once the original package is broken, the floor life of the product at conditions of
FLT012A0-SZ 价格&库存

很抱歉,暂时无法提供与“FLT012A0-SZ”相匹配的价格&库存,您可以联系我们找货

免费人工找货