IND108XW Hornet: Non-Isolated DC-DC Voltage Regulator Modules
24Vdc input; 3Vdc to 18Vdc output; 108W Max Power
Vout+
Vin+
VIN
SYNC
MODULE
Applications
✓
✓
✓
VOUT
SENSE
Cin
Industrial Equipment
Control Boards
Test Equipment
Co
ON/OFF
GND
Electrical Features
Mechanical Features
•
•
•
24V Input voltage with ±20% Tolerance
Output voltage programmable from 3Vdc to
18Vdc via external resistor
Remote On/Off for optional external control
Fixed switching frequency
Sync Capability
Output overcurrent protection (non-latching)
•
•
•
•
TRIM
RTrim
Small size: 33 mm x 13.46 mm x 10 mm (1.3 in x
0.53 in x 0.39 in)
Operating range: -40°C to 105°C ambient
Operating shock to 40G per Mil Std. 810G,
Method 516.4 Procedure I
Operating vibration per Mil Std. 810G, Method
514.5 Procedure I
•
•
•
Process and Safety
•
•
Qualified for 1000h High Temperature Operating Bias, 1000h 85RH/85°C Temperature, Humidity and Bias, 700 cycle -40 to
125°C thermal cycling
ANSI/UL* 62368-1 and CAN/CSA† C22.2 No. 62368-1 Recognized, DIN VDE‡ 0868-1/A11:2017 (EN62368-1:2014/A11:2017)
ISO** 9001 and ISO 14001 certified manufacturing facilities
Compliant to RoHS Directive 2011/65/EU and amended Directive (EU) 2015/863
Compliant to REACH Directive (EC) No 1907/2006
Compatible in a Pb-free or SnPb reflow environment.
Suitable for aqueous clean.
Suitable for conformal coating with dip and vapor deposition. Conformal coating can provide the protection to meet Salt
Fog Test per IEC 60068-2-52 (Severity 3) and Mixed Gas Flow test per Telcordia GR-3108 Outdoor Levels.
3 year warranty
•
•
•
•
•
•
•
•
Device Code
Input Voltage
Output
Voltage
Output
Current (Max.)
On/Off Logic
Comcode
IND108XW
19.2 – 28.8Vdc
3.0 – 18.0Vdc
12A(@3Vout)
Negative
1600102907A
Thermal Performance
Full rated output with natural convection up to 70°C at 3.3Vout and up to 94°C at 18Vout.. Thermal curves for 3 voltages below.
13
13
11
11
7
6
18 Vout
5
5 Vout
9
7
Current (A) vs. Temp ( C)
4
7
NC
0.5m/s (100LFM)
28Vin
1m/s (200LFM)
5
Current (A) vs. Temp ( C)
9
3.3 Vout
Current (A) vs. Temp ( C)
5
3
NC
0.5m/s (100LFM)
1m/s (200LFM)
1
3
3
55
65
May 13, 2021
75
85
95
105
NC
0.5m/s (100LFM)
2
1m/s (200LFM)
2m/s(400LFM)
2m/s(400LFM)
Ruggedized (D) Part (105°C)
55
65
75
85
95
©2017 General Electric Company. All rights reserved.
105
55
65
75
85
95
105
Page 1
Electrical Specifications
Parameter
Operating Input Voltage
Input No Load Current
(VIN = 28.0Vdc, IO = 0, module enabled)
External Capacitance, Ceramic ESR ≥ 1 mΩ
Device
Symbol
Min
Typ
Max
Unit
All
VIN
19.2
24
28.8
Vdc
VO,set = 3 Vdc
IIN,No load
30
mA
VO,set = 18Vdc
IIN,No load
50
mA
All
⎯
CO, max
Efficiency 28VINDC, TA=25°C, Io as per Figure 2
η
100*
μF
94(12V), 95.5(18V)
%
Switching Frequency
All
fsw
⎯
308
⎯
kHz
Output Voltage (Over all line, load, and temperature
conditions)
All
VO, set
-2.5
⎯
+2.5
% VO, set
On/Off Logic High (MODULE OFF) Input High Voltage
All
VIH
1.8
⎯
36
Vdc
On/ Off Logic Low (MODULE ON) Input Low Voltage
All
VIL
-0.2
―
0.3
Vdc
*Additional External Capacitance possible using Tunable Loop
Characteristic Curves
The following figures provide typical characteristics for the IND108XW Hornet at 25oC.
Output Ripple (m Vp-p)
80
3x22uF
70
4x22uF
60
50
40
30
20
10
0
2
4
6
8
10
12
14
16
18
Output Voltage(Volts)
Figure 1. Output Ripple Voltage for various output voltages
and external caps @28Vin. Additional Decoupling cap of
0.01uF used on input and output side
Figure 2. Graph showing maximum output current capability at
different output voltages.
Use electrical profile in Figure 2 for determining baseline output current for a specific voltage. Then thermal curves.
Trim
Rtrim for a desired output voltage, should be as per the following table. The formula in the last column helps determine Rtrim
for other voltages.
Vo (V)
3.3
5.0
6
9
12
15
18
Rtrim (kΩ)
26.92
16.27
13.2
8.43
6.19
4.89
4.04
70
Rtrim =
k
(Vo − 0.7 )
Safety Considerations
For safety agency approval, the power module must be installed in compliance with the spacing and separation requirements of
the end-use safety agency standards listed on the first page of this document. For the converter output to be considered meeting
the requirements of safety extra-low voltage (SELV) or ES1, the input must meet SELV/ES1 requirements. The power module has
extra-low voltage (ELV) outputs when all inputs are ELV. The input to these units is to be provided with a fast-acting fuse with a
maximum rating of 8A in the positive input lead.
May 13, 2021
©2017 General Electric Company. All rights reserved.
Page 2
Tunable Loop
The module is designed for 47uF capacitor on its output. For applications where more than 47uF capacitors would be used on
the output, an additional Resistor (Rtune) and Capacitor (Ctune) would be required in the circuit schematic to compensate for
the additional capacitance. The placement is between the Sense+ pin and Trim pin as per figure below:
The recommended values for Rtune and Ctune for different amounts of external
capacitance are as per the table below:
Vo =
5V
Co
RTUNE
Figure. 3. Circuit diagram
showing connection of RTUNE
and CTUNE to tune the control
loop of the module
CTUNE
5x
6x
22F 22F
8x
22F
10 x
22F
300Ω
240Ω
240Ω
RTUNE 300Ω 300Ω 300Ω 220Ω
3.9nF
CTUNE 560pF 820pF 1200pF 1800pF
300Ω
1800pF 2200pF 3300pF
Vo =
12V
Co
5x
6x
8x
10 x
22F 22F 22F 22F
Synchronization (SYNC)
MODULE
SYNC
+
─
GND
Figure 4. External source connections to synchronize
switching frequency of the module.
The regulator switching frequency can be synchronized to
a signal with an external frequency within a specified
range. Synchronization can be done by using the external
signal applied to the SYNC pin of the module as shown in
Fig. 4, with the converter being synchronized by the rising
edge of the external signal. The Electrical Specifications
table specifies the requirements of the external SYNC
signal. If the SYNC pin is not used, the module should free
run at the default switching frequency. If synchronization
is not being used, connect the SYNC pin to GND.
Recommended Pad Layout
Dimensions are in millimeters and (inches).
Tolerances: x.x mm 0.5 mm (x.xx in. 0.02 in.) [unless otherwise indicated] x.xx mm 0.25 mm (x.xxx in 0.010 in.)
Connect SYNC to GND
if not being used
May 13, 2021
©2017 General Electric Company. All rights reserved.
Page 3
Nozzle Recommendations
300
Per J-STD-020 Rev. D
Bottom Side / First Side Assembly
This module is not recommended for assembly on the bottom side
of a customer board. If such an assembly is attempted, components
may fall off the module during the second reflow process
Lead Free Soldering
Peak Temp 260°C
250
Reflow Temp (°C)
The minimum recommended inside nozzle diameter for reliable
operation is 3mm. The maximum nozzle outer diameter, which will
safely fit within the allowable component spacing, is 7 mm.
200
* Min. Time Above 235°C
15 Seconds
Cooling
Zone
150
Heating Zone
1°C/Second
*Time Above 217°C
60 Seconds
100
50
0
The modules are lead-free (Pb-free) and RoHS compliant and fully
compatible in a Pb-free soldering process. Failure to observe the
instructions below may result in the failure of or cause damage to
the modules and can adversely affect long-term reliability
MSL Rating
The modules have a MSL rating of 2a.
Pb-free Reflow Profile
Power Systems will comply with J-STD-020 Rev. D (Moisture/Reflow
Sensitivity Classification for Nonhermetic Solid State Surface Mount
Devices) for both Pb-free solder profiles and MSL classification
procedures. The suggested Pb-free solder paste is Sn/Ag/Cu (SAC).
The following profile is the recommended linear reflow profile using
Sn/Ag/Cu solder. Soldering outside of the recommended profile
requires testing to verify results and performance.
Reflow Time (Seconds)
Storage and Handling
J-STD-033 Rev. A (Handling, Packing, Shipping and Use of
Moisture/Reflow Sensitive Surface Mount Devices) is
recommended. Moisture barrier bags (MBB) with desiccant are
required for MSL ratings of 2 or greater. These sealed packages
should not be broken until time of use. Once the original
package is broken, the floor life of the product at conditions of
30°C and 60% relative humidity varies according to the MSL
rating (see J-STD-033A). The shelf life for dry packed SMT
packages will be a minimum of 12 months from the bag seal
date, when stored at the following conditions: < 40° C, < 90%
relative humidity.
Post Solder Cleaning and Drying Considerations
Post solder cleaning is usually the final circuit-board assembly
process prior to electrical board testing. The result of inadequate
cleaning and drying can affect both the reliability of a power module
and the testability of the finished circuit-board assembly
Contact Us
For more information, call us at
USA/Canada:
+1 888 546 3243, or +1 972 244 9288
Asia-Pacific:
+86-21-53899666
Europe, Middle-East and Africa:
+49.89.878067-280
Go.ABB/Industrial
GE Critical Power reserves the right to make changes to the product(s) or information contained herein without notice, and
no liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such
product(s) or information.
May 13, 2021
©2017 General Electric Company. All International rights reserved.
Version 1.4
很抱歉,暂时无法提供与“IND108XW”相匹配的价格&库存,您可以联系我们找货