Data Sheet
JNW350R Power Modules; DC-DC Converters
36 – 75 Vdc Input; 28Vdc Output; 350W Output
Features
Compliant to RoHS EU Directive 2011/65/EU (Z versions)
Compliant to RoHS EU Directive 2011/65/EU under
exemption 7b (Lead solder exemption). Exemption 7b
will expire after June 1, 2016 at which time this produc
twill no longer be RoHS compliant (non-Z versions)
Compliant to IPC-9592, Class I, Category 2
High power density: 129 W/in3
Industry standard half-brick pin-out
Industry standard half-brick footprint
57.7mm x 60.7mm x 12.7mm
RoHS Compliant
Applications
RF Power Amplifier
Wireless Networks
Switching Networks
Options
Auto-restart after either output OCP or OVP fault
shutdown (“3” option code)
Auto-restart only after output OCP fault shutdown
(“4” option code)
(2.27” x 2.39” x 0.5”)
2:1 input voltage range
Low output ripple and noise
Constant switching frequency
Single tightly regulated output
No minimum load required
Remote Sense
Output voltage adjustment trim, 16.8Vdc to 32.0Vdc
Accepts transient overloads without shutdown
Latch after output OVP/OCP fault shutdown
Over temperature protection, auto restart
Wide operating case temperature range (-40°C to
100°C)
Shorter pins (“6” or “8” option code)
Unthreaded heatsink holes (-18 option code)
CE mark meets 2006/95/EC directives§
Tunable Loop™ for transient response optimization (T option code)
UL60950-1/CSA† C22.2 No. 60950-1-03 Certified
(CCSAUS) and VDE‡ 0805:2001-12 (EN60950-1) Licensed
ISO** 9001 and ISO 14001 certified manufacturing
facilities
Description
The JNW350R series of dc-dc converters are a new generation of isolated DC/DC power modules providing up to 350W
output power in an industry standard half-brick size footprint, which makes it an ideal choice for high voltage and high
power applications. Threaded-through holes are provided to allow easy mounting or addition of a heatsink for hightemperature applications. The output is fully isolated from the input, allowing versatile polarity configurations and
grounding connections. This module contains an optional new feature, the Tunable LoopTM, that allows the user to
optimize the dynamic response of the converter to match the load with reduced amount of output capacitance, leading to
savings on cost and PWB area.
October 5, 2015
©2012 General Electric Company. All rights reserved.
GE
Data Sheet
JNW350R Power Modules; DC-DC Converters
36 – 75 Vdc Input; 28Vdc Output; 350W Output
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute
stress ratings only, functional operation of the device is not implied at these or any other conditions in excess of those
given in the operations sections of the data sheet. Exposure to absolute maximum ratings for extended periods can
adversely affect the device reliability.
Parameter
Device
Symbol
Min
Max
Unit
Input Voltage
Continuous
All
VIN
-0.3
80
Vdc
Transient, operational (≤100 ms)
All
VIN,trans
-0.3
100
Vdc
Operating Ambient Temperature
Note: When the operating ambient temperature is within
55°C ~85°C, the application of the module refers to the
derating curves of Figures 21 and 22.
All
Ta
-40
85
°C
Operating Case Temperature
(See Thermal Considerations section, Figure 20)
All
Tc
-40
100
°C
Storage Temperature
All
Tstg
-55
125
°C
I/O Isolation Voltage: Input to Case, Input to Output
All
1500
Vdc
All
500
Vdc
Output to Case
Electrical Specifications
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions.
Parameter
Device
Symbol
Min
Typ
Max
Unit
All
VIN
36
48
75
Vdc
(VIN=36V to 75V, IO=IO, max)
All
IIN,max
12.5
Adc
Inrush Transient
All
It
2
A2s
Input Reflected Ripple Current, peak-to-peak
(5Hz to 20MHz, 12μH source impedance; VIN=0V to 75V, IO=
IOmax ; see Figure 7)
All
20
mAp-p
Input Ripple Rejection (120Hz)
All
Operating Input Voltage
(see Figure 12 for VIN, min when using trim-up feature)
Maximum Input Current
2
50
dB
CAUTION: This power module is not internally fused. An input line fuse must always be used.
This power module can be used in a wide variety of applications, ranging from simple standalone operation to being an
integrated part of complex power architecture. To preserve maximum flexibility, internal fusing is not included. Always use
an input line fuse, to achieve maximum safety and system protection. The safety agencies require a time-delay or fastacting fuse with a maximum rating of 20 A (see Safety Considerations section). Based on the information provided in this
data sheet on inrush energy and maximum dc input current, the same type of fuse with a lower rating can be used. Refer
to the fuse manufacturer’s data sheet for further information.
October 5, 2015
©2012 General Electric Company. All rights reserved.
Page 2
GE
Data Sheet
JNW350R Power Modules; DC-DC Converters
36 – 75 Vdc Input; 28Vdc Output; 350W Output
Electrical Specifications (continued)
Parameter
Device
All
Output Voltage Set-point
(VIN=VIN,nom, IO=IO, max, Tc =25°C)
Output Voltage
(Over all operating input voltage, resistive load, and
temperature conditions until end of life)
All
Symbol
Min
Typ
Max
Unit
VO, set
27.5
28
28.5
Vdc
VO
27.15
28.85
Vdc
Output Regulation
Line (VIN=VIN, min to VIN, max)
All
0.1
0.2
%Vo,set
Load (IO=IO, min to IO, max)
All
0.1
0.2
%Vo,set
Temperature (Tc = -40ºC to +100ºC)
All
0.5
1.5
%Vo,set
RMS (5Hz to 20MHz bandwidth)
All
45
55
mVrms
Peak-to-Peak (5Hz to 20MHz bandwidth)1
All
80
200
mVpk-pk
Output Ripple and Noise on nominal output
(VIN=VIN, nom and IO=IO, min to IO, max)
All, except T
-T
-T
External Capacitance (ESR > 50 mΩ)2
CO
440
6500
μF
CO
CO
440
440
470
8,000
μF
μF
All
Io
0
12.5
Adc
Output Current Limit Inception
All
IO, lim
13.1
Output Short Circuit Current (VO≤ 0.25Vdc)
All
IO, sc
Efficiency
VIN=VIN, nom, Tc=25°C IO=IO, max , VO= VO,set
All
η
fsw
Without the Tunable Loop™ (ESRMAX =
With the Tunable Loop™ (ESR > 50 mΩ)3
80mΩ)2
Output Current1
Switching Frequency
17.5
Adc
30
Arms
92
%
300
kHz
Dynamic Load Response
(Io/t=1A/10s; Vin=Vin,nom; Tc=25°C; Tested
with a 470 μF aluminum and a 10 µF ceramic
capacitor across the load.)
Load Change from Io= 50% to 75% of Io,max:
Peak Deviation
All
%VO, set
Vpk
2
Settling Time (Vo