GE
Data Sheet
JNW350R Power Modules; DC-DC Converters
36 – 75 Vdc Input; 28Vdc Output; 350W Output
Features
▪
Compliant to RoHS EU Directive 2011/65/EU and
amended Directive (EU) 2015/863. (Z versions)
▪
Compliant to REACH Directive (EC) No 1907/2006
▪
Compliant to IPC-9592, Class I, Category 2
▪
High power density: 129 W/in3
▪
Industry standard half-brick pin-out
▪
Industry standard half-brick footprint
57.7mm x 60.7mm x 12.7mm
RoHS Compliant
Applications
▪
RF Power Amplifier
▪
Wireless Networks
▪
Switching Networks
Options
▪
Auto-restart after either output OCP or OVP fault
shutdown (“3” option code)
▪
Auto-restart only after output OCP fault shutdown (“4”
option code)
▪
Shorter pins (“6” or “8” option code)
▪
Unthreaded heatsink holes (-18 option code)
▪
Tunable Loop™ for transient response optimization (-T
option code)
(2.27” x 2.39” x 0.5”)
▪
2:1 input voltage range
▪
Low output ripple and noise
▪
Constant switching frequency
▪
Single tightly regulated output
▪
No minimum load required
▪
Remote Sense
▪
Output voltage adjustment trim, 16.8Vdc to 32.0Vdc
▪
Accepts transient overloads without shutdown
▪
Latch after output OVP/OCP fault shutdown
▪
Over temperature protection, auto restart
▪
Wide operating case temperature range (-40°C to 100°C)
▪
CE mark meets 2014/35/EU directive§
▪
ANSI/UL* 62368-1 and CAN/CSA† C22.2 No. 62368-1
Recognized, DIN VDE‡ 0868-1/A11:2017 (EN623681:2014/A11:2017)
▪
ISO** 9001 and ISO 14001 certified manufacturing
facilities
Description
The JNW350R series of dc-dc converters are a new generation of isolated DC/DC power modules providing up to 350W output
power in an industry standard half-brick size footprint, which makes it an ideal choice for high voltage and high power
applications. Threaded-through holes are provided to allow easy mounting or addition of a heatsink for high-temperature
applications. The output is fully isolated from the input, allowing versatile polarity configurations and grounding connections.
This module contains an optional new feature, the Tunable LoopTM, that allows the user to optimize the dynamic response of
the converter to match the load with reduced amount of output capacitance, leading to savings on cost and PWB area.
March 18, 2021
©2012 General Electric Company. All rights reserved.
GE
Data Sheet
JNW350R Power Modules; DC-DC Converters
36 – 75 Vdc Input; 28Vdc Output; 350W Output
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress
ratings only, functional operation of the device is not implied at these or any other conditions in excess of those given in the
operations sections of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect the
device reliability.
Parameter
Device
Symbol
Min
Max
Unit
Input Voltage
Continuous
All
VIN
-0.3
80
Vdc
Transient, operational (≤100 ms)
All
VIN,trans
-0.3
100
Vdc
All
Ta
-40
85
°C
All
Tc
-40
100
°C
Storage Temperature
All
Tstg
-55
125
°C
I/O Isolation Voltage: Input to Case, Input to Output
All
⎯
⎯
1500
Vdc
All
⎯
⎯
500
Vdc
Operating Ambient Temperature
Note: When the operating ambient temperature is within 55°C
~85°C, the application of the module refers to the derating
curves of Figures 21 and 22.
Operating Case Temperature
(See Thermal Considerations section, Figure 20)
Output to Case
Electrical Specifications
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions.
Parameter
Device
Symbol
Min
Typ
Max
Unit
All
VIN
36
48
75
Vdc
All
IIN,max
12.5
Adc
Inrush Transient
All
2
2
A2s
Input Reflected Ripple Current, peak-to-peak
(5Hz to 20MHz, 12μH source impedance; VIN=0V to 75V, IO= IOmax
; see Figure 7)
All
20
mAp-p
Input Ripple Rejection (120Hz)
All
Operating Input Voltage
(see Figure 12 for VIN, min when using trim-up feature)
Maximum Input Current
(VIN=36V to 75V, IO=IO, max)
It
50
dB
CAUTION: This power module is not internally fused. An input line fuse must always be used.
This power module can be used in a wide variety of applications, ranging from simple standalone operation to being an
integrated part of complex power architecture. To preserve maximum flexibility, internal fusing is not included. Always use an
input line fuse, to achieve maximum safety and system protection. The safety agencies require a time-delay or fast-acting fuse
with a maximum rating of 20 A (see Safety Considerations section). Based on the information provided in this data sheet on
inrush energy and maximum dc input current, the same type of fuse with a lower rating can be used. Refer to the fuse
manufacturer’s data sheet for further information.
March 18, 2021
©2012 General Electric Company. All rights reserved.
Page 2
GE
Data Sheet
JNW350R Power Modules; DC-DC Converters
36 – 75 Vdc Input; 28Vdc Output; 350W Output
Electrical Specifications (continued)
Parameter
Device
Output Voltage Set-point
(VIN=VIN,nom, IO=IO, max, Tc =25°C)
All
Output Voltage
(Over all operating input voltage, resistive load, and
temperature conditions until end of life)
All
Symbol
Min
Typ
Max
Unit
VO, set
27.5
28
28.5
Vdc
VO
27.15
⎯
28.85
Vdc
Output Regulation
Line (VIN=VIN, min to VIN, max)
All
⎯
0.1
0.2
%Vo,set
Load (IO=IO, min to IO, max)
All
⎯
0.1
0.2
%Vo,set
Temperature (Tc = -40ºC to +100ºC)
All
⎯
0.5
1.5
%Vo,set
All
⎯
45
55
mVrms
All
⎯
80
200
mVpk-pk
Output Ripple and Noise on nominal output
(VIN=VIN, nom and IO=IO, min to IO, max)
RMS (5Hz to 20MHz bandwidth)
Peak-to-Peak (5Hz to 20MHz
External Capacitance (ESR > 50
bandwidth)1
All, except T
-T
-T
mΩ)2
Without the Tunable Loop™ (ESRMAX = 80mΩ)2
With the Tunable Loop™ (ESR > 50 mΩ) 3
CO
440
6500
μF
CO
CO
440
440
470
8,000
μF
μF
12.5
Adc
Output Current1
All
Io
0
Output Current Limit Inception
All
IO, lim
13.1
Output Short Circuit Current (VO≤ 0.25Vdc)
All
IO, sc
Efficiency
VIN=VIN, nom, Tc=25°C IO=IO, max , VO= VO,set
All
η
⎯
fsw
⎯
Switching Frequency
⎯
17.5
Adc
30
Arms
92
⎯
%
300
⎯
kHz
Dynamic Load Response
(Io/t=1A/10s; Vin=Vin,nom; Tc=25°C; Tested
with a 470 μF aluminum and a 10 µF ceramic
capacitor across the load.)
Load Change from Io= 50% to 75% of Io,max:
Peak Deviation
All
Vpk
2
%VO, set
⎯
⎯
Settling Time (Vo