GE
Data Sheet
KBVW006A0B Series (Sixteenth-Brick) DC-DC Converter Power Modules
36–75Vdc Input; 12.0Vdc Output; 6A Output Current
BARRACUDA* SERIES
RoHS Compliant
Features
▪
Wide input voltage range: 36-75 Vdc
▪
Monotonic startup into prebiased load
▪
Output Voltage adjust: 80% to 110% of Vo,nom
▪
Remote sense
▪
Constant switching frequency
▪
Positive remote On/Off logic
▪
Input under/over voltage protection
▪
Output overcurrent and overvoltage protection
▪
Over-temperature protection
▪
Industry standard, DOSA compliant footprint
33.0 mm x 22.9 mm x 9.3 mm
(1.30 x 0.90 x 0.366 in)
Applications
▪
Distributed Power Architectures
▪
Wireless Networks
▪
Access and Optical Network Equipment
▪
Industrial Equipment
Options
▪
Negative Remote On/Off logic (preferred)
▪
Over current/Over temperature/Over voltage protections
(Auto-restart) (preferred)
▪
Surface Mount version (-S)
▪
Heat Plate version (-H)
▪
For additional options, see Table 2 (Device Options) under
“Ordering Information” section.
▪
Low profile height and reduced component skyline
▪
High efficiency: 91.0%
▪
Wide operating temperature range (-40°C to 85°C)
▪
Compliant to RoHS Directive 2011/65/EU and amended
Directive (EU) 2015/863 (-Z versions )
▪
Compliant to REACH Directive (EC) No 1907/2006
▪
Compliant to IPC-9592A (May 2010), Category 2, Class II
▪
ANSI/UL# 62368-1 and CAN/CSA† C22.2 No. 62368-1
Recognized, DIN VDE‡ 0868-1/A11:2017 (EN623681:2014/A11:2017
▪
CE mark meets 2014/35/EU directive§
▪
Meets the voltage and current requirements for ETSI 300132-2 and complies with and licensed for Basic insulation
rating
▪
2250 Vdc Isolation tested in compliance with IEEE 802.3¤
PoE standards
▪
ISO**9001 and ISO 14001 certified manufacturing facilities
Description
The KBVW006A0B, Sixteenth-brick low-height power module is an isolated dc-dc converters that can deliver up to 6A of output current
and provide a precisely regulated output voltage of 12.0V over a wide range of input voltages (V IN = 36 - 75Vdc). The modules achieve
typical full load efficiency of 91%. The open frame modules construction, available in both surface-mount and through-hole packaging,
enable designers to develop cost and space efficient solutions.
* Trademark of General Electric Company
# UL is a registered trademark of Underwriters Laboratories, Inc.
†
CSA is a registered trademark of Canadian Standards Association.
‡
VDE is a trademark of Verband Deutscher Elektrotechniker e.V.
§
This product is intended for integration into end-user equipment. All of the required procedures of end-use equipment should be followed.
¤ IEEE and 802 are registered trademarks of the Institute of Electrical and Electronics Engineers, Incorporated.
** ISO is a registered trademark of the International Organization of Standards
April 28, 2021
©2014 General Electric Company. All rights reserved.
GE
Data Sheet
KBVW006A0B Series Sixteenth-Brick Power Modules
36–75Vdc Input; 12.0Vdc Output; 6A Output Current
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings only,
functional operation of the device is not implied at these or any other conditions in excess of those given in the operations sections of
the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect the device reliability.
Parameter
Device
Symbol
Min
Max
Unit
Input Voltage
Continuous
All
VIN
-0.3
80
Vdc
Transient, operational (≤100 ms)
All
VIN,trans
-0.3
100
Vdc
All
TA
-40
85
°C
Storage Temperature
All
Tstg
-55
125
°C
I/O Isolation voltage (100% factory Hi-Pot tested)
All
⎯
⎯
2250
Vdc
Operating Ambient Temperature
(see Thermal Considerations section)
Electrical Specifications
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions.
Parameter
Operating Input Voltage
Maximum Input Current
(VIN= VIN, min to VIN, max, IO=IO, max)
Input No Load Current
(VIN = 48V, IO = 0, module enabled)
Input Stand-by Current
Device
Symbol
Min
Typ
Max
Unit
All
VIN
36
48
75
Vdc
All
IIN,max
2.8
Adc
All
IIN,No load
45
IIN,stand-by
8
All
(VIN = 48V, module disabled)
I2t
mA
10
mA
0.5
A2s
Inrush Transient
All
Input Reflected Ripple Current, peak-to-peak
(5Hz to 20MHz, 1μH source impedance; VIN, min to VIN, max, IO= IOmax ;
See Test configuration section)
All
30
mAp-p
Input Ripple Rejection (120Hz)
All
50
dB
CAUTION: This power module is not internally fused. An input line fuse must always be used.
This power module can be used in a wide variety of applications, ranging from simple standalone operation to an integrated part of
sophisticated power architectures. To preserve maximum flexibility, internal fusing is not included, however, to achieve maximum
safety and system protection, always use an input line fuse. The safety agencies require a fast-acting fuse with a maximum rating of 5 A
(see Safety Considerations section). Based on the information provided in this data sheet on inrush energy and maximum dc input
current, the same type of fuse with a lower rating can be used. Refer to the fuse manufacturer’s data sheet for further information.
April 28, 2021
©2014 General Electric Company. All rights reserved.
Page 2
GE
Data Sheet
KBVW006A0B Series Sixteenth-Brick Power Modules
36–75Vdc Input; 12.0Vdc Output; 6A Output Current
Electrical Specifications (continued)
Parameter
Device
Symbol
Min
Typ
Max
Unit
All
VO, set
11.67
12.0
12.25
Vdc
All
VO
11.64
⎯
12.36
Vdc
All
All
All
⎯
⎯
⎯
⎯
⎯
⎯
±0.2
±0.2
±1.0
% VO, set
% VO, set
% VO, set
All
⎯
40
⎯
mVrms
All
⎯
120
⎯
mVpk-pk
Nominal Output Voltage Set-point
VIN= 48V IO=IO, max, TA=25°C)
Output Voltage
(Over all operating input voltage, resistive load, and
temperature conditions until end of life)
Output Regulation
Line (VIN=VIN, min to VIN, max)
Load (IO=IO, min to IO, max)
Temperature (Tref=TA, min to TA, max)
Output Ripple and Noise
(Co=1uF,ceramic+10uF,tantalum,VIN=VIN, min to VIN, max, IO= IO, max ,
TA=TA, min to TA, max)
RMS (5Hz to 20MHz bandwidth)
Peak-to-Peak (5Hz to 20MHz bandwidth)
External Capacitance1
All
CO, max
0
⎯
2,000
μF
Output Current
Output Current Limit Inception (Hiccup Mode )
(VO= 90% of VO, set)
Output Short-Circuit Current
(VO≤250mV) ( Hiccup Mode )
Efficiency
All
Io
0
⎯
6
Adc
All
IO, lim
105
120
140
% Io
All
IO, s/c
2.5
Arms
All
η
91.0
%
All
fsw
350
kHz
All
Vpk
⎯
360
⎯
mV
All
ts
⎯
200
⎯
s
VIN=48V, TA=25°C, IO=IO, max , VO= VO,set
Switching Frequency
Dynamic Load Response
(Co=1uF,ceramic+10uF,tantalum,dIo/dt=0.1A/s; VIN = 48V;
TA=25°C)
Load Change from Io= 50% to 75% or 25% to 50% of Io,max
Peak Deviation
Settling Time (Vo