Data Sheet
NQR002A0X4: Non-Isolated DC-DC Power Modules
3Vdc –14Vdc input; 0.6Vdc to 5.5Vdc output; 2A Output Current
Features
▪
Compliant to RoHS Directive 2011/65/EU and amended
Directive (EU) 2015/863
RoHS Compliant
Applications
▪
Distributed power architectures
▪
Intermediate bus voltage applications
▪
Telecommunications equipment
▪
Servers and storage applications
▪
Networking equipment
▪
Industrial applications
▪
Compliant to REACH Directive (EC) No 1907/2006
▪
Compatible in a Pb-free or SnPb wave-soldering
environment (Z versions)
▪
Wide Input voltage range (3Vdc-14Vdc)
▪
Output voltage programmable from 0.6 Vdc to 5.5Vdc via
external resistor
▪
Tunable LoopTM to optimize dynamic output voltage
response
▪
Fixed switching frequency
▪
Output overcurrent protection (non-latching)
▪
Over temperature protection
▪
Remote On/Off
▪
Small size: 10.4 mm x 13.5 mm x 8.1 mm
(0.41 in x 0.53 in x 0.32 in)
▪
Wide operating temperature range (-40°C to 85°C)
▪
ANSI/UL* 62368-1 and CAN/CSA† C22.2 No. 62368-1
Recognized, DIN VDE‡ 0868-1/A11:2017 (EN623681:2014/A11:201)
▪
ISO** 9001 and ISO 14001 certified manufacturing
facilities
Vout+
Vin+
VIN
VOUT
MODULE
+
CI2
RTUNE
MODULE
CI1
CTUNE
Q3
ON/OFF
GND
CO1
TRIM
RTrim
Description
The NQR002A0X4 SIP power modules are non-isolated dc-dc converters in an industry standard package that can deliver up to 2A of
output current with a full load efficiency of 93% at 5.0Vdc output voltage (VIN = 12Vdc). These modules operate over a wide range
of input voltage (VIN = 3Vdc-14Vdc) and provide a precisely regulated output voltage from 0.6Vdc to 5.5Vdc, programmable via an
external resistor. Features include remote On/Off, adjustable output voltage, over current and over temperature protection. A new
feature, the Tunable LoopTM, allows the user to optimize the dynamic response of the converter to match the load.
†
‡
* UL is a registered trademark of Underwriters Laboratories, Inc.
CSA is a registered trademark of Canadian Standards Association.
VDE is a trademark of Verband Deutscher Elektrotechniker e.V.
** ISO is a registered trademark of the International Organization of Standards
September 3, 2020
©2014 General Electric Company. All rights reserved.
GE
Data Sheet
NQR002A0X4: Non-Isolated DC-DC Power Modules
3Vdc –14Vdc input; 0.6Vdc to 5.5Vdc output; 2A Output Current
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings only,
functional operation of the device is not implied at these or any other conditions in excess of those given in the operations sections of
the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect the device reliability.
Parameter
Input Voltage
Device
Symbol
Min
Max
Unit
All
VIN
-0.3
15
Vdc
All
TA
-40
85
°C
All
Tstg
-55
125
°C
Continuous
Operating Ambient Temperature
(see Thermal Considerations section)
Storage Temperature
Electrical Specifications
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions.
Parameter
Device
Symbol
Min
Typ
Max
Unit
Operating Input Voltage
All
VIN
3
12
14
Vdc
Maximum Input Current
(VIN=3V to 14V, IO=IO, max )
All
IIN,max
2.0
Adc
(VIN = 9Vdc, IO = 0, module enabled)
VO,set = 0.6 Vdc
IIN,No load
20
mA
(VIN = 12Vdc, IO = 0, module enabled)
VO,set = 5.0Vdc
IIN,No load
48
mA
All
IIN,stand-by
1.5
mA
Inrush Transient
All
I2t
Input Reflected Ripple Current, peak-to-peak
(5Hz to 20MHz, 1μH source impedance; VIN =0
to 14V, IO= IOmax ; See Test Configurations)
All
20
mAp-p
Input Ripple Rejection (120Hz)
All
-65
dB
Input No Load Current
Input Stand-by Current
(VIN = 12Vdc, module disabled)
A2s
1
CAUTION: This power module is not internally fused. An input line fuse must always be used.
This power module can be used in a wide variety of applications, ranging from simple standalone operation to an integrated part of
sophisticated power architecture. To preserve maximum flexibility, internal fusing is not included; however, to achieve maximum safety
and system protection, always use an input line fuse. The safety agencies require a fast-acting fuse with a maximum rating of 4A (see
Safety Considerations section). Based on the information provided in this data sheet on inrush energy and maximum dc input current,
the same type of fuse with a lower rating can be used. Refer to the fuse manufacturer’s data sheet for further information.
September 3, 2020
©2014 General Electric Company. All rights reserved.
Page 2
GE
Data Sheet
NQR002A0X4: Non-Isolated DC-DC Power Modules
3Vdc –14Vdc input; 0.6Vdc to 5.5Vdc output; 2A Output Current
Electrical Specifications (continued)
Parameter
Output Voltage Set-point (with 0.5% tolerance for
external resistor used to set output voltage)
Output Voltage
(Over all operating input voltage, resistive load,
and temperature conditions until end of life)
Adjustment Range
Selected by an external resistor
Device
Symbol
Min
All
VO, set
-1.5
All
VO, set
-3.0
All
VO
0.6
Typ
Max
Unit
+1.5
% VO, set
+3.0
% VO, set
5.5
Vdc
⎯
+0.4
% VO, set
⎯
0.8
% VO, set
⎯
+10
mV
⎯
20
mV
⎯
Output Regulation (for Vo 2.5Vdc)
Line (VIN=VIN, min to VIN, max)
All
Load (IO=IO, min to IO, max)
All
-0.4
Output Regulation (for Vo