GE
Data Sheet
Naos Raptor 3A: Non-Isolated DC-DC Power Modules
4.5Vdc –14Vdc input; 0.59Vdc to 6Vdc output; 3A Output Current
Features
RoHS Compliant
Applications
▪
Distributed power architectures
▪
Intermediate bus voltage applications
▪
Telecommunications equipment
▪
Servers and storage applications
▪
Networking equipment
▪
▪
Compliant to RoHS Directive 2011/65/EU and amended
Directive (EU) 2015/863.
▪
Compliant to REACH Directive (EC) No 1907/2006
▪
Compatible in a Pb-free or SnPb wave-soldering
environment (Z versions)
▪
Wide Input voltage range (4.5Vdc-14Vdc)
▪
Output voltage programmable from 0.59 Vdc to 6Vdc via
external resistor
▪
Tunable LoopTM to optimize dynamic output voltage
response
▪
Fixed switching frequency
▪
Output overcurrent protection (non-latching)
▪
Over temperature protection
▪
Remote On/Off
▪
Cost efficient open frame design
▪
Small size: 10.4 mm x 16.5 mm x 7.84 mm
▪
Wide operating temperature range (-40°C to 85°C)
▪
ANSI/UL* 62368-1 and CAN/CSA† C22.2 No. 62368-1
Recognized, DIN VDE‡ 0868-1/A11:2017 (EN623681:2014/A11:2017)
▪
ISO** 9001 and ISO 14001 certified manufacturing
facilities
(0.41 in x 0.65 in x 0.31 in)
Industrial applications
Description
The Naos Raptor 3A SIP power modules are non-isolated dc-dc converters in an industry standard package that can deliver up
to 3A of output current with a full load efficiency of 93% at 3.3Vdc output voltage (VIN = 12Vdc). These modules operate over
a wide range of input voltage (VIN = 4.5Vdc-14Vdc) and provide a precisely regulated output voltage from 0.59Vdc to 6Vdc,
programmable via an external resistor. Features include remote On/Off, adjustable output voltage, over current and over
voltage protection. A new feature, the Tunable LoopTM, allows the user to optimize the dynamic response of the converter to
match the load.
* UL is a registered trademark of Underwriters Laboratories, Inc.
†
CSA is a registered trademark of Canadian Standards Association.
VDE is a trademark of Verband Deutscher Elektrotechniker e.V.
** ISO is a registered trademark of the International Organization of Standards
‡
September 3, 2020
©2016 General Electric Company. All rights reserved.
GE
Data Sheet
Naos Raptor 3A: Non-Isolated DC-DC Power Modules
4.5Vdc –14Vdc input; 0.59Vdc to 6Vdc output; 3A Output Current
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings only,
functional operation of the device is not implied at these or any other conditions in excess of those given in the operations sections of the data
sheet. Exposure to absolute maximum ratings for extended periods can adversely affect the device reliability.
Parameter
Input Voltage
Device
Symbol
Min
Max
Unit
All
VIN
-0.3
15
Vdc
All
TA
-40
85
°C
All
Tstg
-55
125
°C
Continuous
Operating Ambient Temperature
(see Thermal Considerations section)
Storage Temperature
Electrical Specifications
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions.
Parameter
Device
Symbol
Min
Typ
4.5
12
Max
Unit
Operating Input Voltage
All
VIN
Maximum Input Current
All
IIN,max
14
Vdc
2.6
Adc
(VIN = 9Vdc, IO = 0, module ON)
VO,set = 0.6 Vdc
IIN,No load
26
mA
(VIN = 12Vdc, IO = 0, module ON)
VO,set = 5.0Vdc
IIN,No load
60
mA
All
IIN,stand-by
1
mA
Inrush Transient
All
I2t
Input Reflected Ripple Current, peak-to-peak
(5Hz to 20MHz, 1μH source impedance; VIN =0 to 14V,
IO= IOmax ; See Test Configurations)
All
35
mAp-p
Input Ripple Rejection (120Hz)
All
50
dB
(VIN=4.5V to 14V, IO=IO, max )
Input No Load Current
Input Stand-by Current
(VIN = 12Vdc, module disabled)
A2s
1
CAUTION: This power module is not internally fused. An input line fuse must always be used.
This power module can be used in a wide variety of applications, ranging from simple standalone operation to being part of a complex power
architecture. To preserve maximum flexibility, internal fusing is not included, however, to achieve maximum safety and system protection,
always use an input line fuse. The safety agencies require a fast-acting fuse with a maximum rating of 5 A (see Safety Considerations section).
Based on the information provided in this data sheet on inrush energy and maximum dc input current, the same type of fuse with a lower
rating can be used. Refer to the fuse manufacturer’s data sheet for further information.
September 3, 2020
©2016 General Electric Company. All rights reserved.
Page 2
GE
Data Sheet
Naos Raptor 3A: Non-Isolated DC-DC Power Modules
4.5Vdc –14Vdc input; 0.59Vdc to 6Vdc output; 3A Output Current
Electrical Specifications (continued)
Parameter
Device
Symbol
Min
Output Voltage Set-point (with 0.5% tolerance for
external resistor used to set output voltage)
All
VO, set
-1.5
Output Voltage
All
VO, set
-3.0
All
VO
0.59
Typ
Max
Unit
+1.5
% VO, set
+3.0
% VO, set
6.0
Vdc
⎯
+0.2
% VO, set
⎯
0.8
% VO, set
⎯
+5
mV
⎯
20
mV
⎯
(Over all operating input voltage, resistive load,
and temperature conditions until end of life)
end of life) (with 0.1% tolerance trim resistor)
Adjustment Range
Selected by an external resistor
Output Regulation (for Vo 2.5Vdc)
Line (VIN=VIN, min to VIN, max)
All
Load (IO=IO, min to IO, max)
All
-0.2
Output Regulation (for Vo