GE
Data Sheet
QBVW033A0B Barracuda* Series; DC-DC Converter Power Modules
36-75Vdc Input; 12.0Vdc, 33.0A, 400W Output
RoHS Compliant Features
▪ Compliant to RoHS Directive 2011/65/EU and amended Directive
(EU) 2015/863 (-Z versions)
▪ Compliant to REACH Directive (EC) No 1907/2006
▪ Compatible with reflow pin/paste soldering process
▪ High and flat efficiency profile >95.5% at 12Vdc, 30% load to
100% output
▪ Wide Input voltage range: 36-75Vdc
▪ Delivers up to 33Adc output current
▪ Fully very tightly regulated output voltage
▪ Low output ripple and noise
▪ Industry standard, DOSA Compliant Quarter Brick:
58.4 mm x 36.8 mm x 11.7 mm
(2.30 in x 1.45 in x 0.46 in)
Applications
▪ Constant switching frequency
▪
Distributed power architectures
▪
Intermediate bus voltage applications
▪
Servers and storage applications
▪
Networking equipment including Power over Ethernet
(PoE)
▪
Fan assemblies and other systems requiring a tightly
regulated output voltage
▪ Positive Remote On/Off logic
▪ Output over current/voltage protection
Options
▪
Negative Remote On/Off logic (1=option code, factory
preferred)
▪
Auto-restart after fault shutdown (4=option code,
factory preferred)
▪
Remote Sense and Output Voltage Trim (9=option code)
▪
Base plate option (-H=option code)
▪
Passive Droop Load Sharing (-P=option code)
▪ Over temperature protection
▪ Wide operating temperature range (-40°C to 85°C)
▪ ANSI/UL# 62368-1 and CAN/CSA† C22.2 No. 62368-1 Recognized, DIN
VDE‡ 0868-1/A11:2017 (EN62368-1:2014/A11:2017)
▪ CE mark to 2014/35/EU directive§
▪ Meets the voltage and current requirements for ETSI 300-132-2
and complies with and licensed for Basic insulation rating
▪ 2250 Vdc Isolation tested in compliance with IEEE 802.3¤ PoE
standards
▪ ISO** 9001 and ISO14001 certified manufacturing facilities
Description
The QBVW033A0B series of dc-dc converters are a new generation of fully regulated DC/DC power modules designed to support
12Vdc intermediate bus applications where multiple low voltages are subsequently generated using point of load (POL) converters, as
well as other application requiring a tightly regulated output voltage. The QBVW033A0B series operate from an input voltage range
of 36 to 75Vdc and provide up to 33A output current at output voltages of 12Vdc in an industry standard, DOSA compliant quarter
brick. The converter incorporates digital control, synchronous rectification technology, a fully regulated control topology, and
innovative packaging techniques to achieve efficiency exceeding 96% at 12V output. This leads to lower power dissipations such that
for many applications a heat sink is not required. Standard features include on/off control, output overcurrent and over voltage
protection, over temperature protection, input under and over voltage lockout.
The output is fully isolated from the input, allowing versatile polarity configurations and grounding connections. Built-in filtering for
both input and output minimizes the need for external filtering.
* Trademark of General Electric Company
# UL is a registered trademark of Underwriters Laboratories, Inc.
† CSA is a registered trademark of Canadian Standards Association.
‡ VDE is a trademark of Verband Deutscher Elektrotechniker e.V.
§ This product is intended for integration into end-user equipment . All of the required procedures of end-use equipment should be followed.
¤ IEEE and 802 are registered trademarks of the Institute of Electrical and Electronics Engineers, Incorporated.
** ISO is a registered trademark of the International Organization of Standards.
April 29, 2021
©2012 General Electric Company. All rights reserved.
Page 1
GE
Data Sheet
QBVW033A0B Barracuda Series; DC-DC Converter Power Modules
36-75Vdc Input; 12.0Vdc, 33.0A, 400W Output
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings only,
functional operation of the device is not implied at these or any other conditions in excess of those given in the operations sections of
the Data Sheet. Exposure to absolute maximum ratings for extended periods can adversely affect device reliability.
Parameter
Device
Symbol
Min
Max
Unit
VIN
-0.3
75
Vdc
100
Vdc
VIN
80
100
Vdc
All
TA
-40
85
°C
All
Tstg
-55
125
°C
⎯
⎯
* Input over voltage protection will shutdown the output voltage when the input voltage exceeds threshold level.
2250
Vdc
Input Voltage*
Continuous
Operating transient ≤ 100mS
Non- operating continuous
Operating Ambient Temperature
(See Thermal Considerations section)
Storage Temperature
I/O Isolation Voltage (100% factory Hi-Pot tested)
All
Electrical Specifications
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions.
Parameter
Device
Operating Input Voltage
Maximum Input Current
(VIN=0V to 75V, IO=IO, max)
Input No Load Current
(VIN = VIN, nom, IO = 0, module enabled)
Input Stand-by Current
(VIN = VIN, nom, module disabled)
Symbol
Min
Typ
Max
Unit
VIN
36
48
75
Vdc
IIN,max
-
-
12
Adc
All
IIN,No load
All
IIN,stand-by
External Input Capacitance
All
Inrush Transient
All
80
mA
22
mA
100
-
-
μF
-
-
1
A2s
All
-
350
-
mArms
Input Reflected Ripple Current, peak-to-peak
(5Hz to 20MHz, 12μH source impedance; VIN= 48V, IO= IOmax ; see
Figure 11)
All
-
40
-
mAp-p
Input Ripple Rejection (120Hz)
All
-
25
-
dB
I2t
Input Terminal Ripple Current
(Measured at module input pin with maximum specified input
capacitance and < 500uH inductance between voltage source and
input capacitance)
5Hz to 20MHz, VIN= 48V, IO= IOmax
CAUTION: This power module is not internally fused. An input line fuse must always be used.
This power module can be used in a wide variety of applications, ranging from simple standalone operation to an integrated part of
sophisticated power architecture. To preserve maximum flexibility, internal fusing is not included, however, to achieve maximum
safety and system protection, always use an input line fuse. The safety agencies require a fast-acting fuse with a maximum rating of 30
A in the ungrounded input lead of the power supply (see Safety Considerations section). Based on the information provided in this
Data Sheet on inrush energy and maximum dc input current, the same type of fuse with a lower rating can be used. Refer to the fuse
manufacturer’s Data Sheet for further information.
April 29, 2021
©2012 General Electric Company. All rights reserved.
Page 2
GE
Data Sheet
QBVW033A0B Barracuda Series; DC-DC Converter Power Modules
36-75Vdc Input; 12.0Vdc, 33.0A, 400W Output
Electrical Specifications (continued)
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions.
Parameter
Output Voltage Set-point (VIN=VIN,nom, IO=16.5A, TA =25°C)
Output Voltage
(Over all operating input voltage (40V to 75V), resistive load, and
temperature conditions until end of life)
Output Voltage (VIN=36V, TA = 25ºC)
Device
Symbol
Min
Typ
Max
Unit
All
All w/o P
Option
All w/ P
Option
All
VO, set
11.97
12.00
12.03
Vdc
VO
11.76
⎯
12.24
Vdc
VO
11.63
⎯
12.37
Vdc
VO
11.00
⎯
⎯
Vdc
All w/o 9
option
All w/ 9
option
All w/o P or
9 option
All w/ 9
option
All w/ P
Option
All
⎯
0.2
⎯
% VO, set
⎯
0.5
⎯
% VO, set
⎯
0.2
⎯
% VO, set
⎯
1.2
⎯
% VO, set
⎯
0.50
⎯
Vdc
⎯
2
⎯
% VO, set
All
⎯
70
⎯
mVrms
All
⎯
200
⎯
mVpk-pk
0
⎯
10,000
μF
15,000
μF
33
Adc
⎯
Adc
Output Regulation [VIN, min = 40V]
Line (VIN= VIN, min to VIN, max)
Line (VIN= VIN, min to VIN, max)
Load (IO=IO, min to IO, max)
Load (IO=IO, min to IO, max)
Load (IO=IO, min to IO, max), Intentional Droop
Temperature (TA = -40ºC to +85ºC)
Output Ripple and Noise on nominal output
(VIN=VIN, nom and IO=IO, min to IO, max)
RMS (5Hz to 20MHz bandwidth)
Peak-to-Peak (5Hz to 20MHz bandwidth)
External Output Capacitance
For CO >5000uF, IO must be < 50% IO, max during Trise.
When 2 or more modules are in parallel
All
CO, max
-P Option
0
Output Current
All
IO
0
Output Current Limit Inception
All
IO,lim
36.3
40
Efficiency (VIN=VIN, nom, TA=25°C)
IO=100% IO, max, VO= VO,set
All
IO=40% IO, max to 75% IO, max , VO= VO,set
All
Switching Frequency
95.5
η
96.0
%
fsw
150
kHz
Dynamic Load Response
dIO/dt=1A/10s; Vin=Vin,nom; TA=25°C;
(Tested with a 1.0μF ceramic, a 10μF tantalum, and 470μF
capacitor and across the load.)
Load Change from IO = 50% to 75% of IO,max:
Peak Deviation
Settling Time (VO 2000mm3),
Peak temperature over 245C is not suggested due to the
potential reliability risk of components under continuous hightemperature.
Min. sustain duration above 217C : 90 seconds
Min. sustain duration above 180C : 150 seconds
Max. heat up rate: 3C/sec
Max. cool down rate: 4C/sec
In compliance with JEDEC J-STD-020C spec for 2 times reflow
requirement.
Pb-free Reflow Profile
BMP module will comply with J-STD-020 Rev. C
(Moisture/Reflow Sensitivity Classification for
Nonhermetic Solid State Surface Mount Devices) for both Pbfree solder profiles and MSL classification
procedures. BMP will comply with JEDEC J-STD-020C
specification for 3 times reflow requirement. The suggested
Pb-free solder paste is Sn/Ag/Cu (SAC). The recommended
linear reflow profile using Sn/Ag/Cu solder is shown in Figure
24.
April 29, 2021
Preheat time
100-150 Sec.
Ramp up
max. 3°C/Sec
25°C
Time
Figure 25. Recommended linear reflow profile using
Sn/Ag/Cu solder.
MSL Rating
The QBVW033A0B modules have a MSL rating as indicated in
the Device Codes table, last page of this document.
Storage and Handling
The recommended storage environment and handling
procedures for moisture-sensitive surface mount packages is
detailed in J-STD-033 Rev. A (Handling, Packing, Shipping and
Use of Moisture/Reflow Sensitive Surface Mount Devices).
Moisture barrier bags (MBB) with desiccant are required for
MSL ratings of 2 or greater. These sealed packages should not
be broken until time of use. Once the original package is
broken, the floor life of the product at conditions of 30°C and
60% relative humidity varies according to the MSL rating (see
J-STD-033A). The shelf life for dry packed SMT packages will
be a minimum of 12 months from the bag seal date, when
stored at the following conditions: < 40° C, < 90% relative
humidity.
Post Solder Cleaning and Drying
Considerations
Post solder cleaning is usually the final circuit-board assembly
process prior to electrical board testing. The result of
inadequate cleaning and drying can affect both the reliability
of a power module and the testability of the finished
circuit-board assembly. For guidance on appropriate
soldering, cleaning and drying procedures, refer to GE Board
Mounted Power Modules: Soldering and Cleaning Application
Note (AN04-001).
If additional information is needed, please consult with your
GE representative for more details.
©2012 General Electric Company. All rights reserved.
Page 12
GE
Data Sheet
QBVW033A0B Barracuda Series; DC-DC Converter Power Modules
36-75Vdc Input; 12.0Vdc, 33.0A, 400W Output
EMC Considerations
The circuit and plots in Figure 25 shows a suggested
configuration to meet the conducted emission limits of
EN55032 Class A. For further information on designing for
EMC compliance, please refer to the FLT012A0Z data sheet.
Figure 26. EMC Considerations
April 29, 2021
©2012 General Electric Company. All rights reserved.
Page 13
GE
Data Sheet
QBVW033A0B Barracuda Series; DC-DC Converter Power Modules
36-75Vdc Input; 12.0Vdc, 33.0A, 400W Output
Mechanical Outline for QBVW033A0B Through-hole Module
Dimensions are in millimeters and [inches].
Tolerances: x.x mm 0.5 mm [x.xx in. 0.02 in.] (Unless otherwise indicated)
x.xx mm 0.25 mm [x.xxx in 0.010 in.]
*Top side label includes GE name, product designation, and data code.
** Standard pin tail length. Optional pin tail lengths shown in Table 2, Device Options.
TOP VIEW*
SIDE VIEW
BOTTOM VIEW
Pin
Pin
Number Name
1*
VIN(+)
2*
ON/OFF
3*
VIN(-)
4*
VOUT(-)
5†
SENSE(-)
6†
TRIM
7†
SENSE(+)
8*
VOUT(+)
† - Optional Pins
See Table 2
April 29, 2021
©2012 General Electric Company. All rights reserved.
Page 14
GE
Data Sheet
QBVW033A0B Barracuda Series; DC-DC Converter Power Modules
36-75Vdc Input; 12.0Vdc, 33.0A, 400W Output
Mechanical Outline for QBVW033A0B-H (Base plate) Through-hole Module
Dimensions are in millimeters and [inches].
Tolerances: x.x mm 0.5 mm [x.xx in. 0.02 in.] (Unless otherwise indicated)
x.xx mm 0.25 mm [x.xxx in 0.010 in.]
*Side label includes product designation, and data code.
** Standard pin tail length. Optional pin tail lengths shown in Table 2, Device Options.
***Bottom label includes GE name, product designation, and data code
TOP VIEW
SIDE VIEW*
BOTTOM VIEW***
Pin
Pin
Number Name
1*
VIN(+)
2*
ON/OFF
3*
VIN(-)
4*
VOUT(-)
5†
SENSE(-)
6†
TRIM
7†
SENSE(+)
8*
VOUT(+)
† - Optional Pins
See Table 2
April 29, 2021
©2012 General Electric Company. All rights reserved.
Page 15
GE
Data Sheet
QBVW033A0B Barracuda Series; DC-DC Converter Power Modules
36-75Vdc Input; 12.0Vdc, 33.0A, 400W Output
Recommended Pad Layouts
Dimensions are in millimeters and [inches].
Tolerances: x.x mm 0.5 mm [x.xx in. 0.02 in.] (unless otherwise indicated)
x.xx mm 0.25 mm [x.xxx in 0.010 in.]
Through-Hole Modules
Pin
Pin
Number Name
1*
VIN(+)
2*
ON/OFF
3*
VIN(-)
4*
VOUT(-)
5†
SENSE(-)
6†
TRIM
7†
SENSE(+)
8*
VOUT(+)
† - Optional Pins
See Table 2
Hole and Pad diameter recommendations:
Pin Number
Hole Dia mm [in]
1, 2, 3, 5, 6, 7
1.6 [.063]
4, 8
2.2 [.087]
April 29, 2021
Pad Dia mm [in]
2.1 [.083]
3.2 [.126]
©2012 General Electric Company. All rights reserved.
Page 16
GE
Data Sheet
QBVW033A0B Barracuda Series; DC-DC Converter Power Modules
36-75Vdc Input; 12.0Vdc, 33.0A, 400W Output
Packaging Details
All versions of the QBVW033A0Bare supplied as standard in the plastic trays shown in Figure 27.
Tray Specification
Material
PET (1mm)
Max surface resistivity
109 -1011/PET
Color
Clear
Capacity
12 power modules
Min order quantity
24 pcs (1 box of 2 full trays +
1 empty top tray)
Each tray contains a total of 12 power modules. The trays are self-stacking and each shipping box for the QBVW033A0B module
contains 2 full trays plus one empty hold-down tray giving a total number of 24 power modules.
Open Frame Module Tray
Base Plate Module Tray
Figure 27. QBVW033 Packaging Tray
April 29, 2021
©2012 General Electric Company. All rights reserved.
Page 17
GE
Data Sheet
QBVW033A0B Barracuda Series; DC-DC Converter Power Modules
36-75Vdc Input; 12.0Vdc, 33.0A, 400W Output
Ordering Information
Please contact your GE Sales Representative for pricing, availability and optional features.
Table 1. Device Codes
Product codes
QBVW033A0B41Z
QBVW033A0B64Z
QBVW033A0B541Z
QBVW033A0B641Z
QBVW033A0B841Z
QBVW033A0B1-HZ
QBVW033A0B41-HZ
QBVW033A0B61-HZ
QBVW033A0B64-HZ
QBVW033A0B641-HZ
QBVW033A0B841-HZ
QBVW033A0B941-HZ
QBVW033A0B964-HZ
QBVW033A0B9641-HZ
QBVW033A0B41-PZ
QBVW033A0B541-PZ
QBVW033A0B841-PZ
QBVW033A0B1-PHZ
QBVW033A0B41-PHZ
QBVW033A0B61-PHZ
QBVW033A0B641-PHZ
April 29, 2021
Input Voltage
48V (36−75Vdc)
48V (36−75Vdc)
48V (36−75Vdc)
48V (36−75Vdc)
48V (36−75Vdc)
48V (36−75Vdc)
48V (36−75Vdc)
48V (36−75Vdc)
48V (36−75Vdc)
48V (36−75Vdc)
48V (36−75Vdc)
48V (36−75Vdc)
48V (36−75Vdc)
48V (36−75Vdc)
48V (36−75Vdc)
48V (36−75Vdc)
48V (36−75Vdc)
48V (36−75Vdc)
48V (36−75Vdc)
48V (36−75Vdc)
48V (36−75Vdc)
Output
Voltage
12V
12V
12V
12V
12V
12V
12V
12V
12V
12V
12V
12V
12V
12V
12V
12V
12V
12V
12V
12V
12V
Output
Current
33A
33A
33A
33A
33A
33A
33A
33A
33A
33A
33A
33A
33A
33A
33A
33A
33A
33A
33A
33A
33A
Efficiency
95.5%
95.5%
95.5%
95.5%
95.5%
95.5%
95.5%
95.5%
95.5%
95.5%
95.5%
95.5%
95.5%
95.5%
95.5%
95.5%
95.5%
95.5%
95.5%
95.5%
95.5%
©2012 General Electric Company. All rights reserved.
Connector
Type
Through hole
Through hole
Through hole
Through hole
Through hole
Through hole
Through hole
Through hole
Through hole
Through hole
Through hole
Through hole
Through hole
Through hole
Through hole
Through hole
Through hole
Through hole
Through hole
Through hole
Through hole
MSl
Rating
2a
2a
2a
2a
2a
2a
2a
2a
2a
2a
2a
2a
2a
2a
2a
2a
2a
2a
2a
2a
2a
Comcodes
CC109165247
150023767
CC109165263
CC109165692
CC109169347
CC109168126
CC109165255
CC109167813
150023766
CC109165701
150027041
CC109170627
150026356
150019350
CC109169314
CC109167086
CC109169355
CC109167094
CC109167103
CC109167111
CC109167540
Page 18
GE
Data Sheet
QBVW033A0B Barracuda Series; DC-DC Converter Power Modules
36-75Vdc Input; 12.0Vdc, 33.0A, 400W Output
Table 2. Device Options
Contact Us
For more information, call us at
USA/Canada:
+1 877 546 3243, or +1 972 244 9288
Asia-Pacific:
+86-21-53899666
Europe, Middle-East and Africa:
+49.89.878067-280
Go.ABB/Industrial
GE Critical Power reserves the right to make changes to the product(s) or information contained herein without notice, and no liability is assumed as a
result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
April 29, 2021
©2016 General Electric Company. All rights reserved.
Version 1_6