0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
ACTR433S

ACTR433S

  • 厂商:

    ACT

  • 封装:

  • 描述:

    ACTR433S - true one-port, surface-acoustic-wave (SAW) resonator - Advanced Crystal Technology

  • 数据手册
  • 价格&库存
ACTR433S 数据手册
Tel : +44 118 979 1238 Fax : +44 118 979 1283 Email: info@actcrystals.com The ACTR433S/433.92/TO39-1.3 is a true one-port, surface-acoustic-wave (SAW) resonator in a low-profile metal TO-39 case. It provides reliable, fundamental-mode, quartz frequency stabilization i.e. in transmitters or local oscillators operating at 433.920 MHz. 1.Package Dimension (TO-39) 2. Pin 1 2 3 Dimension A B C D E Configuration Input / Output Output / Input Case Ground Data (unit: mm) 9.30±0.20 5.08±0.10 3.40±0.20 3±0.20⁄5±0.20 0.45±0.20 3.Equivalent LC Model and Test Circuit 4.Typical Application Circuits 1) Low-Power Transmitter Application 2) Local Oscillator Application In keeping with our ongoing policy of product evolvement and improvement, the above specification is subject to change without notice. ISO9001: 2000 Registered - Registration number 6830/2 For quotations or further information please contact us at: 3 The Business Centre, Molly Millars Lane, Wokingham, Berks, RG41 2EY, UK Issue : 1 C1 Date : SEPT 04 http://www.actcrystals.com 1 OF 3 Tel : +44 118 979 1238 Fax : +44 118 979 1283 Email: info@actcrystals.com 5.Typical Frequency Response 6.Temperature Characteristics 7.Performance 7-1.Maximum Ratings Rating CW RF Power Dissipation DC Voltage Between Any Two Pins Case Temperature Value 0 ±30V -40 to +85 Units dBm VDC °C 7-2.Electronic Characteristics Characteristic Centre Frequency (+25 °C) Insertion Loss Unloaded Q Quality Factor 50 Ω Loaded Q Turnover Temperature Temperature Stability Turnover Frequency Frequency Temperature Coefficient Frequency Aging Absolute Value during the First Year Absolute Frequency Tolerance from 433.920MHz Sym fC ∆fC IL QU QL T0 f0 FTC |fA| Minimum 433.845 Typical Maximum 433.995 Units MHz kHz ±75 1.3 11,950 1,650 25 fc 0.032 ≤10 1.0 55 1.8 dB °C kHz ppm/°C 2 ppm/yr MΩ DC Insulation Resistance Between Any Two Pins Motional Resistance RF Equivalent RLC Model Motional Inductance Motional Capacitance Pin 1 to Pin 2 Static Capacitance RM LM CM C0 16 70.2381 1.9173 2.65 2.95 23 Ω µH fF 3.25 pF iCAUTION: Electrostatic Sensitive Device. Observe precautions for handling! In keeping with our ongoing policy of product evolvement and improvement, the above specification is subject to change without notice. ISO9001: 2000 Registered - Registration number 6830/2 For quotations or further information please contact us at: 3 The Business Centre, Molly Millars Lane, Wokingham, Berks, RG41 2EY, UK Issue : 1 C1 Date : SEPT 04 http://www.actcrystals.com 2 OF 3 Tel : +44 118 979 1238 Fax : +44 118 979 1283 Email: info@actcrystals.com 1. 2. 3. 4. 5. 6. 7. 8. 9. The centre frequency, f C, is measured at the minimum IL point with the resonator in the 50 Ω test system. Unless noted otherwise, case temperature T C = +25°C±2°C. Frequency aging is the change in f C with time and is specified at +65°C or less. Aging may exceed the specification for prolonged temperatures above +65°C. Typically, aging is greatest the first year after manufacture, decreasing in subsequent years. Turnover temperature, T0, is the temperature of maximum (or turnover) frequency, f 0. The nominal frequency at 2 any case temperature, TC, may be calculated from: f = f 0 [1 - FTC (T 0 - TC) ]. This equivalent RLC model approximates resonator performance near the resonant frequency and is provided for reference only. The capacitance C 0 is the measured static (non-motional) capacitance between Pin1 and Pin2. The measurement includes case parasitic capacitance. Derived mathematically from one or more of the following directly measured parameters: f C, IL, 3 dB bandwidth, fC versus TC, and C 0. The specifications of this device are based on the test circuit shown above and subject to change or obsolescence without notice. Typically, equipment utilizing this device requires emissions testing and government approval, which is the responsibility of the equipment manufacturer. Our liability is only assumed for the Surface Acoustic Wave (SAW) component(s) per se, not for applications, processes and circuits implemented within components or assemblies. Issue : 1 C1 In keeping with our ongoing policy of product evolvement and improvement, the above specification is subject to change without notice. Date : SEPT 04 ISO9001: 2000 Registered - Registration number 6830/2 For quotations or further information please contact us at: 3 The Business Centre, Molly Millars Lane, Wokingham, Berks, RG41 2EY, UK http://www.actcrystals.com 3 OF 3
ACTR433S 价格&库存

很抱歉,暂时无法提供与“ACTR433S”相匹配的价格&库存,您可以联系我们找货

免费人工找货