MPLAB® REAL ICE™ POWER MONITOR INSTRUCTION SHEET
Software Setup
The MPLAB REAL ICE Power Monitor (AC244008) allows the MPLAB
REAL ICE In-Circuit Emulator to monitor current and voltage of the target
board or device. The kit contains a Power Monitor board, power supply and
this instruction sheet.
1. Install the Power Monitor plugin. Select Tools>Plugins, click on the
Available Plugins tab, check “Power Monitor” and click Install. For
more information on plugins, see MPLAB X IDE documentation.
2. Select File>Project Properties. Click on the down arrow on the
“Supported Plugin Board” drop-down box and select “Power Monitor
Board”.
3. Click on the “Real ICE” category. Under the “Trace and Profiling”
option category, set up power sampling. Under the “Power” option,
check “Power target circuit from REAL ICE”, and specify the voltage
under “Voltage Level”. Click OK when complete.
4. Select Tools>Embedded>Power Monitor to open the Power Monitor
window. View the current and voltage values by time and PC.
Monitor and Debug Features
• Monitors current with selectable ranges (up to 1A) and programmable
voltage (up to 5.0V)
• Powers the target (up to 1A)
• Graphs current, voltage and time vs. code execution (PC)
• Additional features are in development
Power Monitor Support
• Power Monitor is supported on MPLAB X IDE 1.70 and above.
• Power Monitor supports all Microchip devices.
• Not all debug features are available when using the Power Monitor.
View the Debug menu to see which functions are active and which
are not available (grayed).
FIGURE:
POWER MONITOR BOARD CONNECTIONS
USB
2012 Microchip Technology Inc.
STATUS
FUNCTION RESET
Hardware Setup
1. Power down the target board and disconnect the USB cable from the
emulator.
2. Unplug any driver board from the driver board slot and remove any
logic probes in the logic probe connector.
3. Plug the Power Monitor board into the emulator driver board slot and
logic probe connector simultaneously.
4. Reconnect the USB cable to the emulator.
5. Plug the three-pronged end of the Power Monitor power adaptor into
a power supply. Plug the single-pronged end into the Power Monitor
board.
6. Connect to the target board via a modular cable. See the emulator
user’s guide (under Documentation) for other connections or
configurations.
Emulator Pod
ACTIVE
Power
Power
Power Monitor
Trigger
Port
Modular Cable
Target
Device
Target Board
Documentation
For the latest information on this board, see the “Emulator Accessories”
chapter of the “MPLAB REAL ICE In-Circuit Emulator User’s Guide for
MPLAB X IDE” (DS52085) or online help file.