DEFENSE LOGISTICS AGENCY
DLA LAND AND MARITIME
POST OFFICE BOX 3990
COLUMBUS, OH 43218-3990
June 19, 2014
Mr. Dmitry Marchenko
Process Engineer
Microsemi HRG
6 Lake Street
Lawrence, MA, 01841
Dear Mr. Marchenko:
RE: Laboratory Suitability MIL-STD-883, Hybrid Microcircuits, FSC 5962, VQ(VQH-14-028176),
CN#s 042751 and 042752
Your hybrid facility at the above address was sample audited the week of March 25, 2014 for
compliance with MIL-PRF-38534 Classes H and K and MIL-STD-883. A satisfactory confidence level of
Laboratory Suitability has been demonstrated. Therefore, your facility at 6 Lake Street, Lawrence, MA
is considered suitably equipped to perform testing on hybrid microcircuits in accordance with MIL-PRF38534 for the following test methods of MIL-STD-883:
TEST (DANVERS LOCATION)
Insulation Resistance
Moisture Resistance
Life Test
Stabilization Bake
Salt Atmosphere
Temperature Cycling
Thermal Shock (Liquid)
Seal
Burn-In
Constant Acceleration
Mechanical Shock
Solderability
Lead Integrity
Vibration, Variable Frequency
External Visual
Internal Visual (Monolithic)
Bond Strength
Internal Visual & Mechanical
Resistance to Solvents
Physical Dimensions
Internal Visual (Hybrid)
Die Shear
PIND
Non-Destruct Bond Pull
Internal Visual (Passive)
883/*750 METHOD
CONDITION
1003
1004
1005
1008
1009
1010
1011
1014
1015
2001
2002
2003
2004
2007
2009
2010
2011
2014
2015
2016
2017
2019
2020
2023
2032
600Vdc, 100nA
N/A
A-D, Tc, Air
C (150˚C), F, Air
A
C
A, B, C
A1, A2, C1
A-D (Ta and Tc,125˚C), Air
A-E & 3000g, Y1 axis
B
N/A
A, B1, B2, D
A
N/A
A, B
D
N/A
N/A
N/A
H, K
N/A
A, B
N/A
H, K
Resistance to Soldering Heat
2036
B
Internal Visual (Transistors)*
*2072
N/A
Internal Visual (Diodes)*
*2073
N/A
All screening, conformance inspection, periodic inspection, and qualification tests must be
performed by a facility that has been issued Laboratory Suitability by DLA Land and Maritime-VQ for
the applicable test method and condition.
This Laboratory Suitability is valid until withdrawn by this Center. This Laboratory Suitability is
subject to the conditions stated in DoD 4120.24-M and SD-6.
Note: Radiation Hardness Assurance Laboratory Suitability is not addressed in this letter.
Please contact Miss Schneider 614-692-0585 with any questions relevant to this letter.
Sincerely,
Digitally signed by
GEMPERLINE.JOSE GEMPERLINE.JOSEPH.L.1230250495
DN: c=US, o=U.S. Government,
ou=PKI, ou=DLA,
PH.L.1230250495 ou=DoD,
cn=GEMPERLINE.JOSEPH.L.1230250495
Date: 2014.06.20 16:39:00 -04'00'
for JAMES ESCHMEYER
Chief
Hybrid Devices Branch