MPLAD30KP14A –
MPLAD30KP400CA
Available
Surface Mount 30,000 Watt Transient
Voltage Suppressor
High-Reliability
screening available in
reference to
MIL-PRF-19500
DESCRIPTION
These high power 30 kW rated transient voltage suppressors in a surface mount package are
provided with design features to minimize thermal resistance and cumulative heating. Typical
applications include lightning and automotive load dump protection. They are particularly effective at
meeting the multi-stroke lightning standard RTCA DO-160, section 22 for aircraft design. This
efficient low profile package design is offered in standoff voltage selections (V WM ) of 14 volts to
400 volts in either unidirectional or bidirectional construction.
Important: For the latest information, visit our website http://www.microsemi.com.
FEATURES
•
Available in both unidirectional and bidirectional construction (bidirectional with CA suffix)
•
High reliability with wafer fabrication and assembly lot traceability
•
All parts surge tested
•
Low profile surface mount package
•
Optional upscreening is available with various screening and conformance inspection options based
on MIL-PRF-19500. Refer to Hirel Non-Hermetic Product Portfolio brochure on our web site for more
details on the screening options.
PLAD
(The cathode is the metal base
under the body of this device.)
•
Suppresses transients up to 30,000 W @ 10/1000 μs (see Figure 1)
•
Moisture classification is Level 1 with no dry pack required per IPC/JEDEC J-STD-020B
•
RoHS compliant versions are available
•
3σ lot norm screening performed on standby current (I D )
Also available:
PLAD15KP
(15,000 watts)
MPLAD15KP7.0A thru
MPLAD15KP200CA
APPLICATIONS / BENEFITS
•
•
•
•
•
•
•
Protection from switching transients and induced RFI
Protection from ESD, and EFT per IEC 61000-4-2 and IEC 61000-4-4
Secondary lightning protection per IEC 61000-4-5 with 42 ohms source impedance:
Class 1,2,3,4,5: MPLAD30KP14A to 400CA
Class 5: MPLAD30KP14A to 400CA (short distance)
Class 5: MPLAD30KP14A to 220CA (long distance)
Secondary lightning protection per IEC 61000-4-5 with 12 ohms source impedance:
Class 1,2,3: MPLAD30KP14A to 400CA
Class 4: MPLAD30KP14A to 220CA
Secondary lightning protection per IEC 61000-4-5 with 2 ohms source impedance:
Class 2: MPLAD30KP10A to 400CA
Class 3: MPLAD30KP14A to 220CA
Class 4: MPLAD30KP14A to 110CA
Pin injection protection per RTCA/DO-160F for Waveform 4 (6.4/69 μs @ 25°C)*:
Level 4: MPLAD30KP14A to 400CA
Level 5: MPLAD30KP14A to 260CA
Pin injection protection per RTCA/DO-160F for Waveform 5A (40/120 μs @25°C)*:
Level 4: MPLAD30KP14A to 64CA
Level 5: MPLAD30KP14A to 26CA
*See MicroNote 132 for further temperature derating selection.
RF01005, Rev G (5/16/14)
©2013 Microsemi Corporation
MSC – Lawrence
6 Lake Street,
Lawrence, MA 01841
Tel: 1-800-446-1158 or
(978) 620-2600
Fax: (978) 689-0803
MSC – Ireland
Gort Road Business Park,
Ennis, Co. Clare, Ireland
Tel: +353 (0) 65 6840044
Fax: +353 (0) 65 6822298
Website:
www.microsemi.com
Page 1 of 6
MPLAD30KP14A –
MPLAD30KP400CA
o
MAXIMUM RATINGS @ 25 C unless otherwise specified
Parameters/Test Conditions
Junction and Storage Temperature
(1)
Thermal Resistance Junction-to-Ambient
Thermal Resistance Junction-to-Case
Peak Pulse Power @ 10/1000 µs
(2)
Value
Unit
-55 to +150
50
1.0
30,000
ºC/W
ºC/W
ºC/W
W
Unidirectional
Bidirectional
t clamping (0 volts to V (BR) min)
Forward Clamping Voltage @ 500 Amps
(3)
Forward Surge Current
Solder Temperature @ 10 s
(5)
Steady-State Power dissipation
Notes: 1.
2.
3.
4.
5.
Symbol
T J and T STG
R ӨJA
R ӨJC
P PP
(3)
T A = 25 °C
T C = 100 °C
很抱歉,暂时无法提供与“MPLAD30KP64CAE3/TR”相匹配的价格&库存,您可以联系我们找货