NOT RECOMMENDED FOR NEW DESIGNS
SY10E164
SY100E164
SY10E164
16:1
MULTIPLEXER
Micrel, Inc.
SY100E164
DESCRIPTION
FEATURES
■ 850ps Data Input to Output
■ Extended 100E VEE range of –4.2V to –5.5V
The SY10/100E164 are 16:1 multiplexers with a
differential output. The select inputs (SEL0,1,2,3) control
which one of the sixteen data inputs (A 0 –A 15 ) is
propagated to the output.
Special attention to the design layout results in a typical
skew between the 16 inputs of only 50ps.
■ Differential output
■ Fully compatible with industry standard 10KH,
100K ECL levels
■ Internal 75KΩ input pull-down resistors
■ Fully compatible with Motorola MC10E/100E164
■ Available in 28-pin PLCC package
BLOCK DIAGRAM
PIN NAMES
Pin
A0
Q
A1
16:1
A14
Q
A15
Function
A0 – A15
Data Inputs
SEL[0:3]
Select Inputs
Q, Q
Outputs
VCCO
VCC to Output
SEL0
SEL1
SEL2
SEL3
M9999-032006
hbwhelp@micrel.com or (408) 955-1690
Rev.: G
1
Amendment: /0
Issue Date: March 2006
SY10E164
SY100E164
Micrel, Inc.
A12
Ordering Information(1)
A13
A14
A15
VCCO
A11
A10
PACKAGE/ORDERING INFORMATION
25 24 23 22 21 20 19
A9
18
26
A8
SEL3
27
17
28
16
VEE
SEL2
SEL0
SEL1
1
PLCC
TOP VIEW
J28-1
2
15
14
6
7
8
9
A4
A3
A2
10 11
A1
5
A5
12
A6
13
A7
3
4
28-Pin PLCC (J28-1)
NC
NC
VCC
Q
Q
VCCO
A0
Part Number
Package
Type
Operating
Range
Package
Marking
Lead
Finish
SY10E164JC
J28-1
Commercial
SY10E164JC
Sn-Pb
SY10E164JCTR(2)
J28-1
Commercial
SY10E164JC
Sn-Pb
SY100E164JC
J28-1
Commercial
SY100E164JC
Sn-Pb
SY100E164JCTR(2)
J28-1
Commercial
SY100E164JC
Sn-Pb
SY10E164JZ(3)
J28-1
Commercial
SY10E164JZ with
Pb-Free bar-line indicator
Matte-Sn
SY10E164JZTR(2, 3)
J28-1
Commercial
SY10E164JZ with
Pb-Free bar-line indicator
Matte-Sn
SY100E164JZ(3)
J28-1
Commercial
SY100E164JZ with
Pb-Free bar-line indicator
Matte-Sn
SY100E164JZTR(2, 3)
J28-1
Commercial
SY100E164JZ with
Pb-Free bar-line indicator
Matte-Sn
Notes:
1. Contact factory for die availability. Dice are guaranteed at TA = 25°C, DC Electricals only.
2. Tape and Reel.
3. Pb-Free package is recommended for new designs.
M9999-032006
hbwhelp@micrel.com or (408) 955-1690
2
SY10E164
SY100E164
Micrel, Inc.
TRUTH TABLE
SEL3
SEL2
SEL1
SEL0
Data
SEL3
SEL2
SEL1
SEL0
Data
L
L
L
L
L
L
A0
H
L
L
L
A8
L
H
A1
L
H
L
L
H
A9
L
H
L
A2
H
L
H
L
A10
L
L
H
H
A3
H
L
H
H
A11
L
H
L
L
A4
H
H
L
L
A12
L
H
L
H
A5
H
H
L
H
A13
L
H
H
L
A6
H
H
H
L
A14
L
H
H
H
A7
H
H
H
H
A15
DC ELECTRICAL CHARACTERISTICS
VEE = VEE (Min.) to VEE (Max.); VCC = VCCO = GND
TA = 0°C
Symbol
Parameter
IIH
Input HIGH Current
IEE
Power Supply Current
10E
100E
TA = +25°C
TA = +85°C
Min.
Typ.
Max.
Min.
Typ.
Max.
Min.
Typ.
Max.
Unit
Condition
—
—
150
—
—
150
—
—
150
µA
—
mA
—
—
—
59
59
71
71
—
—
59
59
71
71
—
—
59
68
71
81
Unit
Condition
ps
—
AC ELECTRICAL CHARACTERISTICS
VEE = VEE (Min.) to VEE (Max.); VCC = VCCO = GND
TA = 0°C
Symbol
tPD
Parameter
Propagation Delay to Output
A Input
SEL0
SEL1
SEL2
SEL3
tskew
Within-Device Skew
tr
tf
Rise/Fall Times
20–80%
TA = +25°C
TA = +85°C
Min.
Typ.
Max.
Min.
Typ.
Max.
Min.
Typ.
Max.
350
500
400
400
400
600
700
675
675
550
850
900
900
900
700
350
500
400
400
400
600
700
675
675
550
850
900
900
900
700
350
500
400
400
400
600
700
675
675
550
850
900
900
900
700
—
50
—
—
50
—
—
50
—
ps
1
275
400
550
275
400
550
275
400
550
ps
—
Note:
1. Within-device skew is defined as the difference in the A to Q delay between the 16 different A inputs.
M9999-032006
hbwhelp@micrel.com or (408) 955-1690
3
SY10E164
SY100E164
Micrel, Inc.
28-PIN PLCC (J28-1)
Rev. 03
MICREL, INC. 2180 FORTUNE DRIVE SAN JOSE, CA 95131
TEL
+ 1 (408) 944-0800
FAX
+ 1 (408) 474-1000
WEB
USA
http://www.micrel.com
The information furnished by Micrel in this data sheet is believed to be accurate and reliable. However, no responsibility is assumed by Micrel for its use.
Micrel reserves the right to change circuitry and specifications at any time without notification to the customer.
Micrel Products are not designed or authorized for use as components in life support appliances, devices or systems where malfunction of a product can
reasonably be expected to result in personal injury. Life support devices or systems are devices or systems that (a) are intended for surgical implant into
the body or (b) support or sustain life, and whose failure to perform can be reasonably expected to result in a significant injury to the user. A Purchaser’s
use or sale of Micrel Products for use in life support appliances, devices or systems is at Purchaser’s own risk and Purchaser agrees to fully indemnify
Micrel for any damages resulting from such use or sale.
© 2006 Micrel, Incorporated.
M9999-032006
hbwhelp@micrel.com or (408) 955-1690
4
很抱歉,暂时无法提供与“SY100E164JC”相匹配的价格&库存,您可以联系我们找货
免费人工找货