0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
3B30-02

3B30-02

  • 厂商:

    AD(亚德诺)

  • 封装:

    -

  • 描述:

    MODULEISOLVOLT-IN+/-50MV

  • 数据手册
  • 价格&库存
3B30-02 数据手册
Isolated Voltage Input 3B30 / 3B31 FEATURES FUNCTIONAL BLOCK DIAGRAM Interfaces, amplifies, & filtersanalog input voltages. Narrow-bandwidth (3Hz) single-channel single conditioning. Module provides simultaneous precision voltage and current outputs. Module circuitry can withstand 220v rms at the input screwterminals Current output withstands 130V rms without damage. All 3B30 & 3B31 series modules are mix-and-match and Hot Swappable Figure 1. 3B30 & 3B31 Functional Block Diagram APPLICATIONS Industrial signal conditioning Industrial signal isolation Industrial signal filtering PRODUCT OVERVIEW The 3B Series of Signal Conditioning I/o Subsystems provide a low-cost, versatile method of transferring analog transducer signals to a data acquisition, monitoring or control system without the inherent noise, non-linearity, drift and extraneous voltages. The modules are designed to directly accept analog signals from Thermocouples, RTD’s, AC and DC Strain Gages, Torque Transducers, Frequency Transducers, LVDTs, millivolt or process current signals. The modules amplify, isolate, linearize and convert the transducer output signals to standardized analog inputs for high-level analog I/O subsystems. The 3B Series Subsystem consists of a 10” relay rack with universal mounting backplane and a family of plug-in (up to 16 per rack) input and output signal conditioning modules. Eight and four channel backplanes are also available. Each backplane incorporates screw terminals for sensor inputs and current outputs and a 26-pin connector for high-level singleended voltage outputs to the user’s equipment. The input modules feature complete signal conditioning circuitry optimized for specific sensors or analog signals and provide two simultaneous high-level analog outputs: 0 to +10V (or +10V) and 4-20 mA (or 0-20 mA). Output modules accept 0 to +10V (or +10V) single-ended signals and provide an isolated 4-20 mA (or 0-20 mA) process signal. All modules feature a universal pin-out and may be readily hot-swapped under full power and interchanged without disrupting field wiring. The Analog Devices 3B Series Signal Conditioning Subsystem is designed to easily handle signal conditioning problems in measurement and control applications. Some typical uses are in microcomputer-based data acquisition systems, programmable controllers, analog recorders, dedicated control systems, and any other applications where monitoring of temperature, pressure, flow and analog signals are required. Since each input module features two simultaneous outputs, the voltage output can be used to provide an input to a microprocessor-based data acquisition or control system while the current output can be used for analog transmission, operator interface, or an analog backup system. Each input module is a single-channel signal conditioner which plugs into a socket on the backplane and accepts its signal from the input screw terminals. All input modules provide input protection, amplification and filtering of the input signal, accuracy of +0.1%, low drift of +1 uV/oC (low-level input modules), and feature two high-level analog outputs that are compatible with most process instrumentation. The isolated input modules also provide +1500 V peak isolation. The choice of a specific 3B module depends upon the type of input signal. Input modules are available to accept millivolt, volt, process current, thermocouple, RTD, AC and DC strain gage, frequency and LVDT inputs. The voltage output of each module is available from the system I/O connector while the current output is available on the output screw terminals. Rev. 0 Information furnished by Analog Devices is believed to be accurate and reliable. However, no responsibility is assumed by Analog Devices for its use, nor for any infringements of patents or other rights of third parties that may result from its use. Specifications subject to change without notice. No license is granted by implication or otherwise under any patent or patent rights of Analog Devices. Trademarks and registered trademarks are the property of their respective companies. One Technology Way, P.O. Box 9106, Norwood, MA 02062-9106, U.S.A. www.analog.com Tel: 781.329.4700 Fax: 781.326.8703 © 2004 Analog Devices, Inc. All rights reserved. 3B30 / 3B31 GENERAL DESCRIPTION set the zero-scale value. Zero suppression can exceed 100% of the input range. This is ideal fro expanded-scale applications requiring high-resolution measurement of a selected portion of an input signal. For users convenience, the zero and span can be factory configured to meet custom range needs (Models 3B30CUSTOM and 3B31-CUSTOM) or can be externally programmed (Models 3B30-00 and 3B31-00) via user supplied resistors inserted in the optional AC1310 plug-on ranging card. Internal low-pass filtering with a 4Hz cutoff (-3dB) two-pole Butterworth filter enhances both 60dB normal-mode and 160 dB common-mode rejection at 50/60 Hz, enabling accurate measurement of small signals in high electrical noise. The 3B30 & 3B31 are narrow-bandwidth (3Hz) single-channel signal conditioning modules which amplify, isolate, filter and protect analog input voltages and provide simultaneous precision voltage and current outputs. Each module performs complete signal conditioning, including isolating (+1500V peak input-to-output and power) and protecting their computer side outputs from damage and loss of signal integrity, and shielding their inputs from damage from field-side over-voltage faults up to 220V rms. The current output withstands 130V rms without damage and interfaces user equipment through screw terminals located on the 3B Series backplane. Each plug-in, mix-andmatch, hot-swappable module is easily field calibrated via frontpanel zero and span adjustments for both voltage and current outputs. Signal isolation is accomplished by transformer coupling with a proprietary modulation technique for linear, stable and reliable performance. The differential input circuit on the field side is fully floating, eliminating the need for any input grounding. A demodulator on the computer side of the signal transformer recovers the original signal, which is then filtered and buffered to provide a low-noise, low-impedance output voltage; this output also drives a voltage-to-current (V/I) converter to provide a simultaneous current output for interfacing versatility. 3B Series Custom-Ranging Program – Externallyprogrammable Models 3B30-00 and 3B31-00, enable the user to configure a special input range by using the optional plug-on AC1310 ranging card, which houses user-supplied resistors to determine zero and span. To facilitate selecting resistors, a Windows program, 3B-CUSTOM, calculates resistor values based on the user-desired input/output ranges. A chopper-stabilized low-drift (+1uV/oC) input amplifier assures stable long-term stability. At the amplifier input, a stable, zero-scale input voltage is subtracted from the input signal to . . Figure 2 Rev. 0 | Page 2 of 8 3B30 / 3B31 3B30 and 3B31 Models Available Model Input Range Output Ranges1 3B30-00 Externally Programmable2 -10 V to +10 V & 0 mA to 20 mA 3B30-01 -10 mV to +10 mV -10 V to +10 V & 0 mA to 20 mA 3B30-02 -50 mV to +50 mV -10 V to +10 V & 0 mA to 20 mA 3B30-03 -100 mV to +100 mV -10 V to +10 V & 0 mA to 20 mA 3B30-Custom * * 3B31-00 Externally Programmable2 -10 V to +10 V & 0 mA to 20 mA 3B31-01 -1 V to +1 V -10 V to +10 V & 0 mA to 20 mA 3B31-02 -5 V to +5 V -10 V to +10 V & 0 mA to 20 mA 3B31-03 -10 V to +10 V -10 V to +10 V & 0 mA to 20 mA 3B31-Custom * -10 V to +10 V & 0 mA to 20 mA 1 Output current range may be user programmed to 4 mA to 20 mA using jumper supplied. Requires AC1310 ranging card. * Custom Input/Output ranges are available. Refer to configuration guide. 2 3B30 and 3B31 Specifications (typical @ +25°C and ±15 V dc, and +24 V dc Power) Description Model 3B30 Model 3B31 Input Range Standard Ranges ±10 mV to ±100 mV ±1 V to ±10 V Custom Ranges ±5 mV to ±500 mV ±0.5 V to ±20 V Output Range Voltage (RL > 2 KΩ) -10 V to +10 V * Current (RL = 0 to 850Ω)1 4 mA to 20 mA or 0 mA to 20 mA * Maximum Current Output Span 0 mA to 31 mA * 2 Accuracy Initial @ +25°C ±0.1% Span * Nonlinearity ±0.01% Span * Stability vs. Temperature Voltage Output Zero Span Current Output ±1 µV/°C (RTI) ±25 ppm of Span/°C ±25 ppm of Reading/°C * ±25 ppm of Span/°C * ±25 ppm of Reading/°C * ±5% of Span * 3 Zero Span 4 Zero and Span Adjustment Range Rev. 0 | Page 3 of 8 3B30 / 3B31 Input Bias Current +3 nA * Input Resistance 15 MΩ 650 kΩ Noise Input, 0.1 Hz to 10 Hz Bandwidth 0.2 µV rms * Output, 100 kHz Bandwidth 50 µV rms * Bandwidth, -3 dB 3 Hz * Output Rise Time, 10% to 90% Span 200 ms * Common-Mode Voltage (CMV) Input-to-Output, Continuous ±1500 V peak, maximum * Transient ANSI/IEEE C37.90.1-1989 * Common Mode Rejection (CMR) 1 kΩ Source Imbalance, 50/60 Hz 160 dB 160 dB 150 dB (3B31-02); 145 dB (3B31-03) Normal Mode Rejection, 50/60 Hz 60 dB * Input Protection Continuous 220 V rms maximum * Transient ANSI/IEEE C37.90.1-1989 * Voltage Output Protection Continuous Short to Ground * Current Output Protection 130 V rms, continuous Power Supply Voltages * 5 ±15 V dc Supplies Rated Operation ±(11.5 V dc to 16.5 V dc) * Current ±10 mA * Sensitivity ±0.01% span/V * Rated Operation +12 V dc to +30 V dc * Current +27 mA @ lout = 20 mA * Sensitivity ±0.0002% span/V * 3.15" x 3.395" x 0.775" 80.0 mm x 86.2 mm x 19.7 mm) * +24 V dc Loop Supply Mechanical Dimensions Environmental Temperature Range Rated Performance -25°C to +85°C * Storage -55°C to +85°C * Relative Humidity, 24 hours 0 to 95% @ +60°C non-condensing * RFI Susceptibility ±0.5% Span error @ 400 MHz, 5 Watt, 3 ft * * Specifications same as model 3B30. 1 For a 0 to 20 mA range, a typical minimum output current is 10 µA. 2 Includes the combined effects of repeatability, hysteresis, and nonlinearity. 3 With respect to the voltage output. 4 A wide range of custom zero suppression and span is available with the 3B30-00 and 3B31-00 models, using the AC1310 ranging card. 5 +24 V dc loop power is required for driving the current output at loads up to 850Ω. If a current output load of 400Ω or less is applied, +15 V dc is sufficient for loop power. If only voltage output is used, loop power is not required. Specifications subject to change without notice. Rev. 0 | Page 4 of 8 3B30 / 3B31 PIN CONFIGURATIONS AND FUNCTIONAL DESCRIPTIONS Figure 3 3B30 & 3B31Input Field Connections Table 1. Pin Function Descriptions— Pin No. 1 2 3 4 Description n/c HI LO n/c Figure 4 . Model 3B Series Module, with pin-out assignments. ESD CAUTION ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily accumulate on the human body and test equipment and can discharge without detection. Although this product features proprietary ESD protection circuitry, permanent damage may occur on devices subjected to high energy electrostatic discharges. Therefore, proper ESD precautions are recommended to avoid performance degradation or loss of functionality. Rev. 0 | Page 5 of 8 3B30 / 3B31 OUTLINE DIMENSIONS Figure 5. Outline Dimensions Rev. 0 | Page 6 of 8 3B30 / 3B31 NOTES Rev. 0 | Page 7 of 8 3B30 / 3B31 NOTES © 2004 Analog Devices, Inc. All rights reserved. Trademarks and registered trademarks are the property of their respective companies. D05093-0-9/04(0) Rev. 0 | Page 8 of 8
3B30-02 价格&库存

很抱歉,暂时无法提供与“3B30-02”相匹配的价格&库存,您可以联系我们找货

免费人工找货