Isolated, Voltage or Current Input
7B30
FEATURES
FUNCTIONAL BLOCK DIAGRAM
Interfaces, amplifies and filters unipolar and bipolar millivolt
and voltage inputs.
Provides a protected precision output of either +1 V to +5 V
or 0 V to +10 V.
A plug-in 250W current sensing resistor is provided to
measure a process current input.
All 7B30 series modules are mix-and-match and Hot
Swappable.
APPLICATIONS
Industrial signal conditioning
Industrial signal isolation
Industrial signal filtering
PRODUCT OVERVIEW
The 7B Series of signal conditioners feature small size, low cost
and a wide output voltage range for a variety of applications
including process control and factory-floor environments. The
single-channel 7B modules accept inputs from a range of
transducers and are fully rated over the extended -40oC to
+85oC industrial temperature range. All 7B Series modules are
rated for a nominal power supply input of +24 VDC; and, for
maximum flexibility, they will accept supply voltages in the +14
VDC to +35 VDC range. The input modules, with the exception
of the 7B21, provide a high-level output voltage that is factory
configured for either the +1 V to +5 V or 0 V to +10 V range.
The 7B21 is a unity gain, isolated input module with an
input/output range of +10V. Output modules are available that
provide either isolated process current or isolated bipolar
voltage output. Model 7B39 converts either a +1 V to +5 V input
to a 4 to 20 mA output or a 0 V to +10 V input to a 0-20 mA
output. The input/output ranges of the 7B39 are factory
configured. The 7B22 is a unity gain module that provides an
isolated +10V output signal. All modules have a universal pinout and may be readily hot-swapped under full power without
disrupting field wiring. Each module accepts analog transducer
signals and transfers them to a process control or factory data
collection system without the inherent noise, non-linearity, drift
and extraneous voltages which frequently accompany the
signals.
Figure 1. 7B30 Functional Block Diagram
The modules feature a maximum nonlinearity of +0.02% and
are factory calibrated to guarantee a maximum accuracy
specification of +0.1%.
The 7B Series offers up to 1500 V rms continuous common
mode voltage isolation and 120 V rms of field wiring input
protection. The power supplies necessary to drive each of the
individual module’s input circuitry are internally isolated,
enabling the 7B Series modules to offer true channel-to-channel
isolation of the input signals.
The modules directly accept analog signals from
thermocouples, RTDs, current loop powered transmitters, and
other process control signals. The 7B Series modules amplify,
linearize, isolate, protect and convert the transducer output
signals to standardized analog inputs for high-level analog I/O
subsystems. The 7B Series Subsystem consists of 19-inch rackcompatible hardware (model AC 1363), with universal
mounting backplane and a family of plug-in (up to 16 per
backplane) input and output signal conditioning modules. Four, eight-, and sixteen-channel backplanes are available. Each
backplane incorporates screw terminals for easy power
connections and field wiring, and includes a 25-pin D-type
connector for interfacing the high-level single-ended voltage
outputs to the user’s equipment. Gold-plated sockets are
provided on each channel of the backplane to ensure the
reliability of each module’s electrical connection.
Rev. 0
Information furnished by Analog Devices is believed to be accurate and reliable.
However, no responsibility is assumed by Analog Devices for its use, nor for any
infringements of patents or other rights of third parties that may result from its use.
Specifications subject to change without notice. No license is granted by implication
or otherwise under any patent or patent rights of Analog Devices. Trademarks and
registered trademarks are the property of their respective companies.
One Technology Way, P.O. Box 9106, Norwood, MA 02062-9106, U.S.A.
www.analog.com
Tel: 781.329.4700
Fax: 781.326.8703
© 2004 Analog Devices, Inc. All rights reserved.
7B30* Product Page Quick Links
Last Content Update: 11/01/2016
Comparable Parts
Design Resources
View a parametric search of comparable parts
•
•
•
•
Documentation
Application Notes
• AN-535: Digital Input/Output Subsystems
Data Sheet
• 7B30: Isolated, Voltage or Current Input Data Sheet
User Guides
• 7B Series User's Manual
7B30 Material Declaration
PCN-PDN Information
Quality And Reliability
Symbols and Footprints
Discussions
View all 7B30 EngineerZone Discussions
Sample and Buy
Visit the product page to see pricing options
Tools and Simulations
• 7B Series I/O Subsystem Software Tools
Technical Support
Reference Materials
Submit a technical question or find your regional support
number
Informational
• Selecting the Right Signal Conditioning Series for Your
Application
* This page was dynamically generated by Analog Devices, Inc. and inserted into this data sheet. Note: Dynamic changes to
the content on this page does not constitute a change to the revision number of the product data sheet. This content may be
frequently modified.
7B30
GENERAL DESCRIPTION
up to 120 V rms line voltage. A one-pole 3 Hz filter
preconditions the input signal prior to amplification by a low
drift input amplifier. Amplitude modulation is used to
implement transformer isolation (1500 V rms input-t-output
and power). Isolated front-end circuitry power is supplied by a
DC/DC converter. The output section contains a two-pole
output filter and subsequent buffer ensures that a low noise, low
impedance ( 2 kΩ)
+1 V to +5 V or 0 V to +10 V
Accuracy2
Initial @ +25°C
3
±0.01% Span (±0.1% Span, maximum)
Nonlinearity
±0.02% Span, maximum
Input Offset vs. Temperature
±0.5 µV/°C
Zero Suppression vs. Temperature
±0.005% (Vz)4/°C
Span vs. Temperature
±35 ppm/°C
Output Offset vs. Temperature
±0.002% Span/°C
Rev. 0 | Page 3 of 8
7B30
Input Bias Current
±1 nA
Input Resistance
Power ON
10 MΩ
Power OFF
30 kΩ, minimum
Output Noise
5 MHz Bandwidth
6 mV peak
10 Hz to 100 kHz Bandwidth
0.4 mV rms
0.1 Hz to 10 Hz Bandwidth
0.6 µV peak
Bandwidth, -3 dB
3 Hz
Output Rise Time, 10% to 90% Span
150 ms
Common-Mode Voltage (CMV)
Input-to-Output and Power
1500 V rms, continuous
Common Mode Rejection (CMR)
Input-to-Output and Power @ 50/60 Hz
160 dB
Normal Mode Rejection @ 50/60 Hz
60 dB
Input Protection
120 V rms, continuous±35 V dc, continuous
Input Transient Protection
ANSI/IEEE C376.90.1-1989IEEE-STD 472IEC 255-4, Class II
Output Resistance
很抱歉,暂时无法提供与“7B30-01-2”相匹配的价格&库存,您可以联系我们找货