0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
AD698APZ

AD698APZ

  • 厂商:

    AD(亚德诺)

  • 封装:

    PLCC28_11.58X11.58MM

  • 描述:

    通用LVDT信号调节器

  • 数据手册
  • 价格&库存
AD698APZ 数据手册
a Universal LVDT Signal Conditioner AD698 FEATURES Single Chip Solution, Contains Internal Oscillator and Voltage Reference No Adjustments Required Interfaces to Half-Bridge, 4-Wire LVDT DC Output Proportional to Position 20 Hz to 20 kHz Frequency Range Unipolar or Bipolar Output Will Also Decode AC Bridge Signals Outstanding Performance Linearity: 0.05% Output Voltage: 611 V Gain Drift: 20 ppm/8C (typ) Offset Drift: 5 ppm/8C (typ) FUNCTIONAL BLOCK DIAGRAM VOLTAGE REFERENCE AMP OSCILLATOR AD698 B A B FILTER AMP A PRODUCT DESCRIPTION PRODUCT HIGHLIGHTS The AD698 is a complete, monolithic Linear Variable Differential Transformer (LVDT) signal conditioning subsystem. It is used in conjunction with LVDTs to convert transducer mechanical position to a unipolar or bipolar dc voltage with a high degree of accuracy and repeatability. All circuit functions are included on the chip. With the addition of a few external passive components to set frequency and gain, the AD698 converts the raw LVDT output to a scaled dc signal. The device will operate with half-bridge LVDTs, LVDTs connected in the series opposed configuration (4-wire), and RVDTs. 1. The AD698 offers a single chip solution to LVDT signal conditioning problems. All active circuits are on the monolithic chip with only passive components required to complete the conversion from mechanical position to dc voltage. The AD698 contains a low distortion sine wave oscillator to drive the LVDT primary. Two synchronous demodulation channels of the AD698 are used to detect primary and secondary amplitude. The part divides the output of the secondary by the amplitude of the primary and multiplies by a scale factor. This eliminates scale factor errors due to drift in the amplitude of the primary drive, improving temperature performance and stability. The AD698 uses a unique ratiometric architecture to eliminate several of the disadvantages associated with traditional approaches to LVDT interfacing. The benefits of this new circuit are: no adjustments are necessary; temperature stability is improved; and transducer interchangeability is improved. The AD698 is available in two performance grades: Grade AD698AP AD698SQ Temperature Range –40°C to +85°C –55°C to +125°C Package 28-Pin PLCC 24-Pin Cerdip 2. The AD698 can be used with many different types of position sensors. The circuit is optimized for use with any LVDT, including half-bridge and series opposed, (4 wire) configurations. The AD698 accommodates a wide range of input and output voltages and frequencies. 3. The 20 Hz to 20 kHz excitation frequency is determined by a single external capacitor. The AD698 provides up to 24 volts rms to differentially drive the LVDT primary, and the AD698 meets its specifications with input levels as low as 100 millivolts rms. 4. Changes in oscillator amplitude with temperature will not affect overall circuit performance. The AD698 computes the ratio of the secondary voltage to the primary voltage to determine position and direction. No adjustments are required. 5. Multiple LVDTs can be driven by a single AD698 either in series or parallel as long as power dissipation limits are not exceeded. The excitation output is thermally protected. 6. The AD698 may be used as a loop integrator in the design of simple electromechanical servo loops. 7. The sum of the transducer secondary voltages do not need to be constant. REV. B Information furnished by Analog Devices is believed to be accurate and reliable. However, no responsibility is assumed by Analog Devices for its use, nor for any infringements of patents or other rights of third parties which may result from its use. No license is granted by implication or otherwise under any patent or patent rights of Analog Devices. © Analog Devices, Inc., 1995 One Technology Way, P.O. Box 9106, Norwood. MA 02062-9106, U.S.A. Tel: 617/329-4700 Fax: 617/326-8703 AD698–SPECIFICATIONS (@ T = +258C, V A Parameter CM = 0 V, and V+, V– = 615 V dc, unless otherwise noted) Min AD698SQ Typ Max Min AD698AP Typ Max TRANSFER FUNCTION1 VOUT = A × 500 µA × R2 B OVERALL ERROR TMIN to TMAX 0.4 SIGNAL OUTPUT CHARACTERISTICS Output Voltage Range Output Current, TMIN to TMAX Short Circuit Current Nonlinearity2 TMIN to TMAX Gain Error3 Gain Drift Output Offset Offset Drift Excitation Voltage Rejection4 Power Supply Rejection (± 12 V to ± 18 V) PSRR Gain PSRR Offset Common-Mode Rejection (± 3 V) CMRR Gain CMRR Offset Output Ripple5 EXCITATION OUTPUT CHARACTERISTICS (@ 2.5 kHz) Excitation Voltage Range Excitation Voltage (Resistors Are 1% Absolute Values) (R1 = Open)6 (R1 = 12.7 kΩ) (R1 = 487 Ω) Excitation Voltage TC7 Output Current TMIN to TMAX Short Circuit Current DC Offset Voltage (Differential, R1 = 12.7 kΩ) TMIN to TMAX Frequency Frequency TC Total Harmonic Distortion SIGNAL INPUT CHARACTERISTICS A/B Ratio Usable Full-Scale Range Signal Voltage B Channel Signal Voltage A Channel Input Impedance Input Bias Current (BIN, AIN) Signal Reference Bias Current Excitation Frequency POWER SUPPLY REQUIREMENTS Operating Range Dual Supply Operation (± 10 V Output) Single Supply Operation 0 V to +10 V Output 0 V to 10 V Output Current (No Load at Signal and Excitation Outputs) TMIN to TMAX OPERATING TEMPERATURE RANGE 1.65 611 0.4 V 1.65 611 11 20 75 0.1 20 0.02 5 100 11 20 75 0.1 20 0.02 5 100 6500 61.0 6100 61 625 Unit 6500 61.0 6100 61 625 % of FS V mA mA ppm of FS % of FS ppm/°C of FS % of FS ppm/°C of FS ppm/dB 50 15 300 100 50 15 300 100 ppm/V ppm/V 25 2 4 100 100 25 2 4 100 100 ppm/V ppm/V mV rms 2.1 24 2.1 24 V rms 1.2 2.6 14 2.15 4.35 21.2 1.2 2.6 14 2.15 4.35 21.2 V rms V rms V rms ppm/°C mA rms mA rms mA 6100 20 k mV Hz ppm/°C dB 30 100 50 40 60 30 20 30 6100 20 k 30 20 200 –50 0.1 0.1 0.0 200 –50 0.9 3.5 3.5 200 1 2 0 13 ± 13 5 10 20 k 36 17.5 17.5 –2– 0.l 0.1 0.0 0.9 3.5 3.5 200 1 2 0 13 ± 13 5 10 20 k 36 17.5 17.5 12 –55 100 50 40 60 15 18 +125 12 –40 V rms V rms kΩ µA µA Hz V V 15 18 V V mA mA +85 °C REV. B AD698 NOTES 1 A and B represent the Mean Average Deviation (MAD) of the detected sine waves V A and VB. The polarity of VOUT is affected by the sign of the A comparator, i.e., multiply VOUT × +1 for ACOMP+ > ACOMP–, and VOUT × –1 for ACOMP– > ACOMP+. 2 Nonlinearity of the AD698 only in units of ppm of full scale. Nonlinearity is defined as the maximum measured deviation of the AD698 output voltage from a straight line. The straight line is determined by connecting the maximum produced full-scale negative voltage with the maximum produced full-scale positive voltage. 3 See Transfer Function. 4 For example, if the excitation to the primary changes by 1 dB, the gain of the system will change by typically 100 ppm. 5 Output ripple is a function of the AD698 bandwidth determined by C1 and C2. A 1000 pF capacitor should be connected in parallel with R2 to reduce the output ripple. See Figures 7, 8 and 13. 6 R1 is shown in Figures 7, 8 and 13. 7 Excitation voltage drift is not an important specification because of the ratiometric operation of the AD698. 8 From TMIN to TMAX the overall error due to the AD698 alone is determined by combining gain error, gain drift and offset drift. For example, the typical overall error for the AD698AP from T MIN to TMAX is calculated as follows: Overall Error = Gain Error at +25°C (± 0.2% Full Scale) + Gain Drift from –40°C to +25°C (20 ppm/°C × 65°C) + Offset Drift from –40°C to +25°C (5 ppm/°C × 65°C) = ± 0.36% of full scale. Note that 1000 ppm of full scale equals 0.1% of full scale. Specifications subject to change without notice. Specifications shown in boldface are tested on all production units at final electrical test. Results from those tested are used to calculate outgoing quality levels. All min and max specifications are guaranteed, although only those shown in boldface are tested on all production units. CONNECTION DIAGRAMS ABSOLUTE MAXIMUM RATINGS Total Supply Voltage (+VS to –VS) . . . . . . . . . . . . . . . . . 36 V Storage Temperature Range P Package . . . . . . . . . . . . . . . . . . . . . . . . . –65°C to +150°C Q Package . . . . . . . . . . . . . . . . . . . . . . . . –65°C to +150°C Operating Temperature Range AD698SQ . . . . . . . . . . . . . . . . . . . . . . . . –55°C to +125°C AD698AP . . . . . . . . . . . . . . . . . . . . . . . . . –40°C to +85°C Lead Temperature Range (Soldering 60 sec) . . . . . . . . +300°C Power Dissipation Derates above +65°C P Package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 mW/°C Q Package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 mW/°C –VS +VS 2 1 28 27 26 OFF1 EXC1 3 OFF2 NC 4 LEV1 5 25 NC LEV2 6 24 SIG REF FREQ1 7 AD698 FREQ2 8 TOP VIEW (Not to Scale) 23 SIG OUT 22 FEEDBACK 21 OUT FILT NC 9 20 AFILT1 BFILT2 11 19 AFILT2 +ACOMP NC = NO CONNECT –ACOMP 14 15 16 17 18 +AIN NC –BIN 12 13 –AIN θJA 60°C/W 62°C/W BFILT1 10 +BIN THERMAL CHARACTERISTICS θJC P Package 30°C/W Q Package 26°C/W EXC2 28-Pin PLCC ORDERING GUIDE Model Package Description Package Option AD698AP AD698SQ 28-Pin PLCC 24-Pin Double Cerdip P-28A Q-24A 24-Pin Cerdip –VS 1 24 +VS EXC1 2 23 OFFSET1 EXC2 3 22 OFFSET2 LEV1 4 21 SIG REF LEV2 5 20 SIG OUT AD698 FREQ1 6 TOP VIEW 19 FEEDBACK FREQ2 7 (Not to Scale) 18 OUT FILT BFILT1 8 17 AFILT1 BFILT2 9 16 AFILT2 –BIN 10 15 –ACOMP +BIN 11 14 +ACOMP –AIN 12 13 +AIN CAUTION ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily accumulate on the human body and test equipment and can discharge without detection. Although the AD698 features proprietary ESD protection circuitry, permanent damage may occur on devices subjected to high energy electrostatic discharges. Therefore, proper ESD precautions are recommended to avoid performance degradation or loss of functionality. REV. B –3– WARNING! ESD SENSITIVE DEVICE AD698 Typical Characteristics (at +25°C and V = ±15 V unless otherwise noted) 240 120 200 80 160 TYPICAL GAIN DRIFT – ppm/°C GAIN AND OFFSET PSRR – ppm/V S GAIN PSRR 15–18V 120 80 40 GAIN PSRR 12–15V 20 0 OFFSET PSRR 12–15V 40 20 0 –20 –40 –60 OFFSET PSRR 15–18V –20 –60 –40 –20 0 20 40 60 80 100 120 –80 –60 140 TEMPERATURE – °C 0 20 40 60 80 100 120 140 Figure 3. Typical Gain Drift vs. Temperature 0 20 OFFSET CMRR ± 3V 15 TYPICAL OFFSET DRIFT – ppm/°C –05 GAIN AND OFFSET CMRR – ppm/V –20 TEMPERATURE – °C Figure 1. Gain and Offset PSRR vs. Temperature –10 –15 –20 –25 –30 GAIN CMRR ± 3V –35 10 5 0 –5 –10 –15 –40 –45 –60 –40 –40 –20 0 20 40 60 80 TEMPERATURE – °C 100 120 –20 –60 140 –40 –20 0 20 40 60 80 100 120 140 TEMPERATURE – °C Figure 2. Gain and Offset CMRR vs. Temperature Figure 4. Typical Offset Drift vs. Temperature –4– REV. B AD698 THEORY OF OPERATION gain error in the output. The AD698, eliminates these errors by A block diagram of the AD698 along with an LVDT (linear variable differential transformer) connected to its input is shown in Figure 5 below. The LVDT is an electromechanical transducer—its input is the mechanical displacement of a core, and its output is an ac voltage proportional to core position. Two popular types of LVDTs are the half-bridge type and the series opposed or four-wire LVDT. In both types the moveable core couples flux between the windings. The series-opposed connected LVDT transducer consists of a primary winding energized by an external sine wave reference source and two secondary windings connected in the series opposed configuration. calculating the ratio of the LVDT output to its input excitation in order to cancel out any drift effects. This device differs from the AD598 LVDT signal conditioner in that it implements a different circuit transfer function and does not require the sum of the LVDT secondaries (A + B) to be constant with stroke length. The AD698 block diagram is shown below. The inputs consist of two independent synchronous demodulation channels. The B channel is designed to monitor the drive excitation to the LVDT. The full wave rectified output is filtered by C2 and sent to the computational circuit. Channel A is identical except that the comparator is pinned out separately. Since the A channel may reach 0 V output at LVDT null, the A channel demodulator is usually triggered by the primary voltage (B Channel). In addition, a phase compensation network may be required to add a phase lead or lag to the A Channel to compensate for the LVDT primary to secondary phase shift. For half-bridge circuits the phase shift is noncritical, and the A channel voltage is large enough to trigger the demodulator. The output voltage across the series secondary increases as the core is moved from the center. The direction of movement is detected by measuring the phase of the output. Half-bridge LVDTs have a single coil with a center tap and work like an autotransformer. The excitation voltage is applied across the coil; the voltage at the center tap is proportional to position. The device behaves similarly to a resistive voltage divider. C2 VOLTAGE REFERENCE AMP BFILT1 +VS BFILT2 OSCILLATOR B AD698 R2 –BIN A B V/I FILTER C5 CHANNEL B ±1 +BIN AMP OUT FILTER FILTER C4 FB VOUT A COMP DUTY CYCLE DIVIDER A/B = 1 = 100% DUTY –ACOMP COMP Figure 5. Functional Block Diagram +ACOMP The AD698 energizes the LVDT coil, senses the LVDT output voltages and produces a dc output voltage proportional to core position. The AD698 has a sine wave oscillator and power amplifier to drive the LVDT. Two synchronous demodulation stages are available for decoding the primary and secondary voltages. A decoder determines the ratio of the output signal voltage to the input drive voltage (A/B). A filter stage and output amplifier are used to scale the resulting output. OFF 2 FILTER –AIN V/I +AIN ±1 DEMODULATOR OFF 1 IREF 500µA V AD698 A CHANNEL AFILT1 AFILT2 –VS C3 Figure 6. AD698 Block Diagram The oscillator comprises a multivibrator that produces a triwave output. The triwave drives a sine shaper that produces a low distortion sine wave. Frequency and amplitude are determined by a single resistor and capacitor. Output frequency can range from 20 Hz to 20 kHz and amplitude from 2 V to 24 V rms. Total harmonic distortion is typically –50 dB. Once both channels are demodulated and filtered a division circuit, implemented with a duty cycle multiplier, is used to calculate the ratio A/B. The output of the divider is a duty cycle. When A/B is equal to 1, the duty cycle will be equal to 100%. (This signal can be used as is if a pulse width modulated output is required.) The duty cycle drives a circuit that modulates and filters a reference current proportional to the duty cycle. The output amplifier scales the 500 µA reference current converting it to a voltage. The output transfer function is thus: The AD698 decodes LVDTs by synchronously demodulating the amplitude modulated input (secondaries), A, and a fixed input reference (primary or sum of secondaries or fixed input), B. A common problem with earlier solutions was that any drift in the amplitude of the drive oscillator corresponded directly to a REV. B A B VOUT = IREF × A/B × R2, where IREF = 500 µA –5– AD698 CONNECTING THE AD698 3. Select a suitable LVDT that will operate with an excitation frequency of 2.5 kHz. The Schaevitz E100, for instance, will operate over a range of 50 Hz to 10 kHz and is an eligible candidate for this example. The AD698 can easily be connected for dual or single supply operation as shown in Figures 7, 8 and 13. The following general design procedures demonstrate how external component values are selected and can be used for any LVDT that meets AD698 input/output criteria. The connections for the A and B channels and the A channel comparators will depend on which transducer is used. In general follow the guidelines below. 4. Select excitation frequency determining component C1. C1 = 35 µF Hz/f EXCITATION Parameters set with external passive components include: excitation frequency and amplitude, AD698 input signal frequency, and the scale factor (V/inch). Additionally, there are optional features; offset null adjustment, filtering, and signal integration, which can be implemented by adding external components. +15V 6.8µF –15V 100nF 100nF 6.8µF 1 –VS AD698 +VS 24 R4 2 EXC1 OFFSET1 23 3 EXC2 OFFSET2 22 R3 +15V 6.8µF 100nF 4 LEV1 SIG REF 21 5 LEV2 SIG OUT 20 SIGNAL REFERENCE RL R1 –15V 6.8µF 100nF 1 –VS AD698 2 EXC1 +VS 24 6 FREQ1 FEEDBACK 19 R4 C4 1000pF C1 OFFSET1 23 7 FREQ2 R3 3 EXC2 OFFSET2 22 4 LEV1 SIG REF 21 SIGNAL REFERENCE SIG OUT 20 6 FREQ1 FEEDBACK 19 C1 15nF C4 7 FREQ2 OUT FILT 18 8 BFILT1 AFILT1 17 8 BFILT1 AFILT1 17 9 BFILT2 AFILT2 16 C3 VOUT R2 33kΩ OUT FILT 18 C2 RL R1 5 LEV2 1000pF 10 –BIN –ACOMP 15 11 +BIN +ACOMP 14 12 –AIN +AIN 13 A 9 BFILT2 AFILT2 16 10 –BIN –ACOMP 15 11 +BIN +ACOMP 14 12 –AIN +AIN 13 1M C PHASE LAG A B RT Figure 7. Interconnection Diagram for Half-Bridge LVDT and Dual Supply Operation C RS D D PHASE LEAD A B C RS B PHASE LAG/LEAD NETWORK C3 C2 VOUT R2 C RT RS C C PHASE LAG = Arc Tan (Hz RC); PHASE LEAD = Arc Tan 1/(Hz RC) WHERE R = RS// (RS + RT) D Figure 8. AD698 Interconnection Diagram for Series Opposed LVDT and Dual Supply Operation DESIGN PROCEDURE DUAL SUPPLY OPERATION Figure 7 shows the connection method for half-bridge LVDTs. Figure 8 demonstrates the connections for 3- and 4-wire LVDTs connected in the series opposed configuration. Both examples use dual ± 15 volt power supplies. B. Determine the Oscillator Amplitude Amplitude is set such that the primary signal is in the 1.0 V to 3.5 V rms range and the secondary signal is in the 0.25 V to 3.5 V rms range when the LVDT is at its mechanical full-scale position. This optimizes linearity and minimizes noise susceptibility. Since the part is ratiometric, the exact value of the excitation is relatively unimportant. A. Determine the Oscillator Frequency Frequency is often determined by the required BW of the system. However, in some systems the frequency is set to match the LVDT zero phase frequency as recommended by the manufacturer; in this case skip to Step 4. 5. Determine optimum LVDT excitation voltage, VEXC. For a 4-wire LVDT determine the voltage transformation ratio, VTR, of the LVDT at its mechanical full scale. VTR = LVDT sensitivity × Maximum Stroke Length from null. 1. Determine the mechanical bandwidth required for LVDT position measurement subsystem, fSUBSYSTEM. For this example, assume fSUBSYSTEM = 250 Hz. LVDT sensitivity is listed in the LVDT manufacturer’s catalog and has units of volts output per volts input per inch displacement. The E100 has a sensitivity of 2.4 mV/V/mil. In the event that LVDT sensitivity is not given by the manufacturer, it can be computed. See section on determining LVDT sensitivity. 2. Select minimum LVDT excitation frequency approximately 10 × fSUBSYSTEM. Therefore, let excitation frequency = 2.5 kHz. –6– REV. B AD698 Multiply the primary excitation voltage by the VTR to get the expected secondary voltage at mechanical full scale. For example, for an LVDT with a sensitivity of 2.4 mV/V/mil and a full scale of ± 0.1 inch, the VTR = 0.0024 V/V/Mil × 100 mil = 0.24. Assuming the maximum excitation of 3.5 V rms, the maximum secondary voltage will be 3.5 V rms × 0.24 = 0.84 V rms, which is in the acceptable range. b. Full-scale core displacement from null, d Conversely the VTR may be measured explicitly. With the LVDT energized at its typical drive level VPRI, as indicated by the manufacturer, set the core displacement to its mechanical full-scale position and measure the output VSEC of the secondary. Compute the LVDT voltage transformation ratio, VTR. VTR = VSEC//VPRI. For the E100, VSEC = 0.72 V for VPRI = 3 V. VTR = 0.24. VOUT is measured with respect to the signal reference, Pin 21, shown in Figure 7. S × d = VTR and also equals the ratio A/B at mechanical full scale. The VTR should be converted to units of V/V. For a full-scale displacement of d inches, voltage out of the AD698 is computed as VOUT = S × d × 500 µA × R2 Solving for R2, R2 = VOUT S × d × 500 µA (1) For VOUT = ± 10 V full-scale range (20 V span) and d = ± 0.1 inch full-scale displacement (0.2 inch span) For situations where LVDT sensitivity is low, or the mechanical FS is a small fraction of the total stroke length, an input excitation of more than 3.5 V rms may be needed. In this case a voltage divider network may be placed across the LVDT primary to provide smaller voltage for the +BIN and –BIN input. If, for example, a network was added to divide the B Channel input by 1/2, then the VTR should also be reduced by 1/2 for the purpose of component selection. R2 = 20V = 83. 3 kΩ 2.4 × 0.2 × 500 µA VOUT as a function of displacement for the above example is shown in Figure 10. VOUT (VOLTS) Check the power supply voltages by verifying that the peak values of VA and VB are at least 2.5 volts less than the voltages at +VS and –VS. +10 +0.1d (INCHES) –0.1 6. Referring to Figure 9, for VS = ± 15 V, select the value of the amplitude determining component R1 as shown by the curve in Figure 9. –10 Figure 10. VOUT (± 10 V Full Scale) vs. Core Displacement (± 0.1 Inch) 30 E. Optional Offset of Output Voltage Swing 9. Selections of R3 and R4 permit a positive or negative output voltage offset adjustment. VEXC – V rms 25 20  1 1 VOS = 1.2 V × R2 ×  –  R3 + 2 kΩ R 4 + 2 kΩ  15 V rms (2) For no offset adjustment R3 and R4 should be open circuit. To design a circuit producing a 0 V to +10 V output for a displacement of +0.1 inch, set VOUT to +10 V, d = 0.2 inch and solve Equation (1) for R2. 10 5 VOUT (VOLTS) 0 0.01 0.1 1 10 100 +5 1k R1 – kΩ +0.1d (INCHES) –0.1 Figure 9. Excitation Voltage VEXC vs. R1 7. C2, C3 and C4 are a function of the desired bandwidth of the AD698 position measurement subsystem. They should be nominally equal values. –5 Figure 11. VOUT (± 5 V Full Scale) vs. Core Displacement (± 0.1 Inch) –4 C2 = C3 = C4 = 10 Farad Hz/f5UBSYSTEM (Hz) This will produce a response shown in Figure 11. If the desired system bandwidth is 250 Hz, then In Equation (2) set VOS = 5 V and solve for R3 and R4. Since a positive offset is desired, let R4 be open circuit. Rearranging Equation (2) and solving for R3 C2 = C3 = C4 = 10-4 Farad Hz/250 Hz = 0.4 µF See Figures 14, 15 and 16 for more information about AD698 bandwidth and phase characterization. R3 = 1.2 × R2 – 2 kΩ = 7.02 kΩ VOS D. Set the Full-Scale Output Voltage 8. To compute R2, which sets the AD698 gain or full-scale output range, several pieces of information are needed: a. LVDT sensitivity, S REV. B –7– AD698 11. The voltage drop across R5 must be greater than Note that VOS should be chosen so that R3 cannot have negative value . 1.2V V 2 + 10 kΩ  + 250 µA + OUT  Volts  R4 + 2 kΩ 4 × R2  Figure 12 shows the desired response. VOUT (VOLTS) Therefore +10 +5 –0.1 1.2V V + 250 µA + OUT  2 + 10 kΩ   R4 + 2 kΩ 4 × R2  Ohms R5 ≥ 100 µA +0.1d (INCHES) Based upon the constraints of R5 + R6 (Step 10) and R5 (Step 11), select an interim value of R6. Figure 12. VOUT (0 V–10 V Full Scale) vs. Displacement (± 0.1 Inch) 12. Load current through RL returns to the junction of R5 and R6, and flows back to VPS. Under maximum load conditions, make sure the voltage drop across R5 is met as defined in Step 11. DESIGN PROCEDURE SINGLE SUPPLY OPERATION Figure 13 shows the single supply connection method. As a final check on the power supply voltages, verify that the peak values of VA and VB are at least 2.5 volts less than the voltage between +VS and –VS. +30V Vps 0.1µF 6.8µF R5 13. C5 is a bypass capacitor in the range of 0.1 µF to 1 µF. C5 Gain Phase Characteristics R6 1 –VS AD698 To use an LVDT in a closed-loop mechanical servo application, it is necessary to know the dynamic characteristics of the transducer and interface elements. The transducer itself is very quick to respond once the core is moved. The dynamics arise primarily from the interface electronics. Figures 14, 15 and 16 show the frequency response of the AD698 LVDT Signal Conditioner. Note that Figures 15 and 16 are basically the same; the difference is frequency range covered. Figure 15 shows a wider range of mechanical input frequencies at the expense of accuracy. +VS 24 R4 2 EXC1 OFFSET1 23 3 EXC2 OFFSET2 22 4 LEV1 SIG REF 21 5 LEV2 SIG OUT 20 R3 SIGNAL REFERENCE RL R1 VOUT R2 6 FREQ1 FEEDBACK 19 C4 1000pF C1 7 FREQ2 OUT FILT 18 8 BFILT1 AFILT1 17 9 BFILT2 AFILT2 16 10 C3 C2 0 10 –BIN –ACOMP 15 11 +BIN +ACOMP 14 –10 A 12 –AIN –20 +AIN 13 C GAIN – dB PHASE LAG/LEAD NETWORK 1M 0.1µF 2.0µF B –30 0.33µF –40 D –50 PHASE LAG A B RS D C RT RS PHASE LAG = Arc Tan (Hz RC); C C PHASE LEAD = Arc Tan 1/(Hz RC) WHERE R = RS// (RS + RT) 0 D 0.1µF –60 PHASE SHIFT – Degrees RT C R2 = 81kΩ fEXC = 2.5kHz –70 C RS –60 PHASE LEAD A B Figure 13. Interconnection Diagram for Single Supply Operation For single supply operation, repeat Steps 1 through 10 of the design procedure for dual supply operation. R5, R6 and C5 are additional component values to be determined. VOUT is measured with respect to SIGNAL REFERENCE. –120 2.0µF 0.33µF –180 –240 R2 = 81kΩ fEXC = 2.5kHz –300 –360 10. Compute a maximum value of R5 and R6 based upon the relationship –420 0 100 1k FREQUENCY – Hz 10k R5 + R6 ≤ VPS/100 µA Figure 14. Gain and Phase Characteristics vs. Frequency (0 kHz–10 kHz) –8– REV. B AD698 10 Figure 16 shows a more limited frequency range with enhanced accuracy. The figures are transfer functions with the input to be considered as a sinusoidally varying mechanical position and the output as the voltage from the AD698; the units of the transfer function are volts per inch. The value of C2, C3, and C4, from Figure 7, are all equal and designated as a parameter in the figures. The response is approximately that of two real poles. However, there is appreciable excess phase at higher frequencies. An additional pole of filtering can be introduced with a shunt capacitor across R2, Figure 7; this will also increase phase lag. 0.033µF 0 –10 0.1µF GAIN – dB –20 0.01µF –30 –40 –50 R2 = 81kΩ fEXC = 10kHz –60 When selecting values of C2, C3 and C4 to set the bandwidth of the system, a trade-off is involved. There is ripple on the “dc” position output voltage, and the magnitude is determined by the filter capacitors. Generally, smaller capacitors will give higher system bandwidth and larger ripple. Figures 17 and 18 show the magnitude of ripple as a function of C2, C3 and C4, again all equal in value. Note also a shunt capacitor across R2, Figure 7, is shown as a parameter. The value of R2 used was 81 kΩ with a Schaevitz E100 LVDT. –70 0 0.033µF PHASE SHIFT – Degrees –60 –120 0.01µF –180 0.1µF –240 1k R2 = 81kΩ fEXC = 10kHz –300 –360 100 0 100 1k FREQUENCY – Hz 10k 100k RIPPLE – mV rms –420 Figure 15. Gain and Phase Characteristics vs. Frequency (0 kHz–50 kHz) 10 1 10 2.5kHz, C SHUNT 1nF 0.01µF 0 2.5kHz, C SHUNT 10nF –10 0.1 0.01 0.033µF GAIN – dB –20 0.1µF –40 1k R2 = 81kΩ fEXC = 10kHz –60 100 RIPPLE – mV rms –70 0.01µF 0 PHASE SHIFT – Degrees 10 Figure 17. Output Voltage Ripple vs. Filter Capacitance –30 –50 10 1 –60 10kHz, CSHUNT 1nF 0.1µF –120 10kHz, CSHUNT 10nF 0.033µF –180 0.1 0.001 R2 = 81kΩ fEXC = 10kHz –240 –300 –360 0.01 0.1 1 C2, C3, C4; C2 = C3 = C4 – µF 10 Figure 18. Output Voltage Ripple vs. Filter Capacitance 0 100 1k FREQUENCY – Hz 10k Figure 16. Gain and Phase Characteristics vs. Frequency (0 kHz–10 kHz) REV. B 0.1 1 C2, C3, C4; C2 = C3 = C4 – µF –9– AD698 – Low Cost Setpoint Controller – Mechanical Follower Servo Loop – Differential Gaging and Precision Differential Gaging Determining LVDT Sensitivity LVDT sensitivity can be determined by measuring the LVDT secondary voltages as a function of primary drive and core position, and performing a simple computation. AC BRIDGE SIGNAL CONDITIONER Energize the LVDT at its recommended primary drive level, VPRI (3 V rms for the E100). Set the core displacement to its mechanical full-scale position and measure secondary voltages VA and VB. Sensitivity = Bridge circuits which use dc excitation are often plagued by errors caused by thermocouple effects, 1/f noise, dc drifts in the electronics, and line noise pickup. One way to get around these problems is to excite the bridge with an ac waveform, amplify the bridge output with an ac amplifier, and synchronously demodulate the resulting signal. The ac phase and amplitude information from the bridge is recovered as a dc signal at the output of the synchronous demodulator. The low frequency system noise, dc drifts, and demodulator noise all get mixed to the carrier frequency and can be removed by means of a lowpass filter. VSECONDARY V PRI × d From Figure 19, Sensitivity = 0.72 3 V × 100 mils = 2.4 mV /V mil The AD698 with the addition of a simple ac gain stage can be used to implement an ac bridge. Figure 20 shows the connections for such a system. The AD698 oscillator provides ac excitation for the bridge. The low level bridge signal is amplified by the gain stage created by A1, A2 to provide a differential input to the A Channel of the AD698. The signal is then synchronously detected by A Channel. The B Channel is used to detect the level of the bridge excitation. The ratio of A/B is then calculated and converted to an output voltage by R2. An optional phase lag/lead network can be added in front of the A comparator to adjust for phase delays through the bridge and the amplifier, or if the phase delay is small, it can be ignored or compensated for by a gain adjustment. VSEC WHEN VPRI 3V rms VA 1.71V rms 0.99V rms VB d = –100 mils d=0 d = +100 mils Figure 19. LVDT Secondary Voltage vs. Core Displacement Thermal Shutdown and Loading Considerations The AD698 is protected by a thermal overload circuit. If the die temperature reaches 165°C, the sine wave excitation amplitude gradually reduces, thereby lowering the internal power dissipation and temperature. Due to the ratiometric operation of the decoder circuit, only small errors result from the reduction of the excitation amplitude. Under these conditions the signal-processing section of the AD698 continues to meet its output specifications. The thermal load depends upon the voltage and current delivered to the load as well as the power supply potentials. An LVDT Primary will present an inductive load to the sine wave excitation. The phase angle between the excitation voltage and current must also be considered, further complicating thermal calculations. APPLICATIONS Most of the applications for the AD598 can also be implemented with the AD698. Please refer to the applications written for the AD598 for a detailed explanation. See AD598 data sheet for: – Proving Ring-Weigh Scale – Synchronous Operation of Multiple LVDTs – High Resolution Position-to-Frequency Circuit This circuit can be used for resistive bridges such as strain gages, or for inductive or capacitive bridges that are commonly used for pressure or flow sensors. The low level signal outputs of these sensors are susceptible to noise and interference and are good candidates for ac signal processing techniques. Component Selection Amplifiers A1, A2 will be chosen depending on the type of bridge that is conditioned. Capacitive bridges should use an amplifier with low bias current; a large bleeder resistor will be required from the amplifier inputs to ground to provide a path for the dc bias current. Resistive and inductive bridges can use a more general purpose amplifier. The dc performance of A1, A2 are not as important as their ac performance. DC errors such as voltage offset will be chopped out by the AD698 since they are not synchronous to the carrier frequency. The oscillator amplitude and span resistor for the AD698 may be chosen by first computing the transfer function or sensitivity of the bridge and the ac amplifier. This ratio will correspond to the A/B term in the AD698 transfer function. For example, suppose that a resistive strain gage with a sensitivity, S, of 2 mV/V at full scale is used. Select an arbitrary target value for A/B that is close to its maximum value such as A/B = 0.8. Then choose a gain for the ac amplifier so that the strain gage transfer function from excitation to output also equals 0.8. Thus the required amplifier gain will be [A/B]/ S; or 0.8/ 0.002 V/V = 400. Then select values for RS and RG. For the gain stage: –10– REV. B AD698 Since A/B is known, the value of R2, the output FS resistor may be chosen by the formula: 2 × RS  VOUT =  × V IN  RG + 1  VOUT = A/B × 500 µA × R2 Solving for VOUT/VIN = 400 and setting RG = 100 Ω then: For a 10 V output at FS, with an A/B of 0.8; solve for R2. RS = [400 – 1] × RG/2 = 19.95 kΩ R2 = 10 V [0.8 × 500 µA] = 25.0 kΩ Choose an oscillator amplitude that is in the range of 1 V to 3.5 V rms. For an input excitation level of 3 V rms, the output signal from the amplifier gain stage will be 3.5 V rms × 0.8 V or 2.4 V rms, which is in the acceptable range. This will result in a VOUT of 10 V for a full-scale signal from the bridge. The other components, C1, C2, C3, C4 may be selected by following the guidelines on general device operation mentioned earlier. If a gain trim is required, then a trim resistor can be used to adjust either R2 or RG. Bridge offsets should be adjusted by a trim network on the OFFSET 1 and OFFSET 2 pins of the AD698. +15V 6.8µF –15V 6.8µF 100nF 100nF 1 –VS AD698 +VS 24 R4 2 EXC1 OFFSET1 23 3 EXC2 OFFSET2 22 4 LEV1 SIG REF 21 5 LEV2 SIG OUT 20 R3 SIGNAL REFERENCE RL R1 VOUT R2 6 FREQ1 FEEDBACK 19 RESISTORS, INDUCTORS OR CAPACITORS C4 1000pF C1 7 FREQ2 OUT FILT 18 8 BFILT1 AFILT1 17 9 BFILT2 AFILT2 16 C3 C2 A1 10 –BIN –ACOMP 15 11 +BIN +ACOMP 14 12 –AIN +AIN 13 RS RG A B PHASE LAG A B C PHASE LAG/LEAD NETWORK RS RT RS C A2 DUAL OP AMP D PHASE LEAD A B C RS D C RT RS C C D PHASE LAG = Arc Tan (Hz RC); PHASE LEAD = Arc Tan 1/(Hz RC) WHERE R = RS// (RS + RT) Figure 20. AD698 Interconnection Diagram for AC Bridge Applications REV. B –11– AD698 OUTLINE DIMENSIONS Dimensions shown in inches and (mm). 24-Pin Cerdip (Wide) 0.005 (0.13) MIN C1827a–5–7/95 0.098 (2.49) MAX 13 24 0.610 (15.5) 0.520 (13.2) PIN 1 1 12 1.280 (32.51) MAX 0.200 (5.08) MAX 0.150 (3.81) MIN 0.200 (5.08) 0.125 (3.18) 0.023 (0.58) 0.014 (0.36) 0.100 (2.54) BSC 0.620 (15.75) 0.590 (15.00) 0.060 (1.52) 0.015 (0.38) 0.070 (1.78) 0.030 (0.76) SEATING PLANE 0.015 (0.38) 0.008 (0.20) 15 ° 0° 28-Pin PLCC 0.048 (1.21) 0.042 (1.07) 0.048 (1.21) 0.042 (1.07) 4 0.056 (1.42) 0.042 (1.07) 0.050 (1.27) BSC 0.025 (0.63) 0.015 (0.38) 26 PIN 1 IDENTIFIER 5 0.180 (4.57) 0.165 (4.19) 25 0.021 (0.53) 0.013 (0.33) 0.430 (10.92) 0.390 (9.91) TOP VIEW 0.032 (0.81) 0.026 (0.66) 19 11 12 18 0.040 (1.01) 0.025 (0.64) 0.456 (11.58) SQ 0.450 (11.43) 0.110 (2.79) 0.085 (2.16) 0.495 (12.57) SQ 0.485 (12.32) PRINTED IN U.S.A. 0.020 (0.50) R –12– REV. B
AD698APZ 价格&库存

很抱歉,暂时无法提供与“AD698APZ”相匹配的价格&库存,您可以联系我们找货

免费人工找货
AD698APZ
  •  国内价格
  • 1+139.04650

库存:0