10-Bit Digital Temperature Sensor
(AD7416) and 4-/1-Channel ADCs
AD7416/AD7417/AD7418
Data Sheet
FUNCTIONAL BLOCK DIAGRAMS
10-bit ADC with 15 μs and 30 μs conversion times
Single and 4 single-ended analog input channels
On-chip temperature sensor: −40°C to +125°C
On-chip track-and-hold
Overtemperature indicator
Automatic power-down at the end of a conversion
Wide operating supply range: 2.7 V to 5.5 V
I2C-compatible serial interface
Selectable serial bus address allows connection of up to 8
AD7416/AD7417 devices to a single bus
AD7416 is a superior replacement for LM75
10-BIT
ANALOG-TO-DIGITAL
CONVERTER
BAND GAP
TEMPERATURE
SENSOR
AD7416
TEMPERATURE
VALUE
REGISTER
SETPOINT
COMPARATOR
TOTI SETPOINT
REGISTER
ADDRESS
POINTER
REGISTER
THYST SETPOINT
REGISTER
FAULT
QUEUE
COUNTER
CONFIGURATION
REGISTER
A0 7
SERIAL BUS
INTERFACE
A1 6
A2 5
Data acquisition with ambient temperature monitoring
Industrial process control
Automotive
Battery-charging applications
Personal computers
A configuration register allows programming of the sense of the
OTI output (active high or active low) and its operating mode
(comparator or interrupt). A programmable fault queue counter
allows the number of out-of-limit measurements that must
occur before triggering the OTI output to be set to prevent
spurious triggering of the OTI output in noisy environments.
OTI
4
GND
1
SDA
2
SCL
VDD
5
14
TOTI SETPOINT B
REGISTER
TEMP
SENSOR
GENERAL DESCRIPTION
The temperature sensor on the parts can be accessed via multiplexer Channel 0. When Channel 0 is selected and a conversion
is initiated, the resulting ADC code at the end of the conversion
gives a measurement of the ambient temperature (±1°C at 25°C).
On-chip registers can be programmed with high and low temperature limits, and an open-drain overtemperature indicator (OTI)
output is provided, which becomes active when a programmed
limit is exceeded.
3
Figure 1. AD7416
REFIN
CHARGE
DISTRIBUTION
DAC
AIN1 7
AIN2 8
MUX
AIN3 9
A>B
4
OTI
3
SCL
2
SDA
A
REF
2.5V
SAMPLING
CAPACITOR
DATA OUT
I2C
CLOCK CONTROL
LOGIC
INTERFACE
AIN4 10
AD7417
VBALANCE
1
16
6
15
13
12
11
NC
NC
GND
CONVST
A0
A1
A2
01126-002
The AD7417 and AD7418 are 10-bit, 4-channel and single-channel
ADCs with an on-chip temperature sensor that can operate from a
single 2.7 V to 5.5 V power supply. The devices contain a 15 μs
successive approximation converter, a 5-channel multiplexer, a
temperature sensor, a clock oscillator, a track-and-hold, and a
reference (2.5 V). The AD7416 is a temperature-monitoring only
device in an 8-lead package.
VDD
NC = NO CONNECT
Figure 2. AD7417
VDD
REFIN
7
6
TOTI SETPOINT B
REGISTER
TEMP
SENSOR
3
OTI
2
SCL
1
SDA
A
CHARGE
DISTRIBUTION
DAC
REF
2.5V
AIN 5
A>B
MUX
SAMPLING
CAPACITOR
DATA OUT
I2C
CLOCK CONTROL
LOGIC
INTERFACE
AD7418
VBALANCE
4
8
GND
CONVST
01126-003
APPLICATIONS
8
01126-001
FEATURES
Figure 3. AD7418
Rev. J
Document Feedback
Information furnished by Analog Devices is believed to be accurate and reliable. However, no
responsibility is assumed by Analog Devices for its use, nor for any infringements of patents or other
rights of third parties that may result from its use. Specifications subject to change without notice. No
license is granted by implication or otherwise under any patent or patent rights of Analog Devices.
Trademarks and registered trademarks are the property of their respective owners.
One Technology Way, P.O. Box 9106, Norwood, MA 02062-9106, U.S.A.
Tel: 781.329.4700 ©1998–2018 Analog Devices, Inc. All rights reserved.
Technical Support
www.analog.com
AD7416/AD7417/AD7418
Data Sheet
TABLE OF CONTENTS
Features .............................................................................................. 1
On-Chip Reference .................................................................... 11
Applications ....................................................................................... 1
Temperature Measurement ....................................................... 12
General Description ......................................................................... 1
Internal Register Structure ........................................................ 12
Functional Block Diagrams ............................................................. 1
Serial Bus Interface..................................................................... 14
Revision History ............................................................................... 2
OTI Output ................................................................................. 17
Product Highlights ........................................................................... 3
Fault Queue ................................................................................. 17
Specifications..................................................................................... 4
Power-On Defaults ..................................................................... 17
AD7417/AD7418 Specifications................................................. 4
Operating Modes ........................................................................ 17
AD7416 Specifications ................................................................. 6
CONVST Start Mode ................................................................. 18
Absolute Maximum Ratings ............................................................ 7
Applications Information .............................................................. 19
ESD Caution .................................................................................. 7
Supply Decoupling ..................................................................... 19
Pin Configurations and Function Descriptions ........................... 8
Power-On Reset .......................................................................... 19
Terminology .................................................................................... 10
Mounting the AD7416/AD7417/AD7418 .............................. 19
Theory of Operation ...................................................................... 11
Fan Controller............................................................................. 19
Circuit Information .................................................................... 11
Thermostat .................................................................................. 19
Converter Details........................................................................ 11
System with Multiple AD7416 Devices ................................... 20
Typical Connection Diagram.................................................... 11
Outline Dimensions ....................................................................... 21
Analog Inputs .............................................................................. 11
Ordering Guide .......................................................................... 22
REVISION HISTORY
4/2018—Rev. I to Rev. J
Changes to Product Title ................................................................. 1
Changes to Ordering Guide .......................................................... 22
11/2010—Rev. H to Rev. I
Changes to Figure 19 ...................................................................... 16
2/2009—Rev. G to Rev. H
Updated Format .................................................................. Universal
Changes to Data Sheet Title, Figure 2 and Figure 3 ..................... 1
Moved Product Highlights Section ................................................ 3
Changes to Table 1 ............................................................................ 4
Changes to Endnote 1, Table 2 ........................................................ 6
Added Figure 5 Caption................................................................... 7
Changes to Table 4 ............................................................................ 8
Changes to Table 5 and Table 6 ....................................................... 9
Changes to On-Chip Reference Section ...................................... 11
Changes to Figure 13 ...................................................................... 12
Changes to Table 8 and Table 10................................................... 13
Changes to Figure 15, Figure 16, and Figure 17 ......................... 15
Changes to Reading Data from the AD7416/AD7417/AD7418
Section, Figure 18, and Figure 19 ................................................. 16
Change to Mode 1 .......................................................................... 17
Changes to Figure 22 Caption and CONVST Pin Mode
Section .............................................................................................. 18
Moved Figure 21 and Figure 22 .................................................... 18
Changes to Power-On Reset Section ............................................ 19
Updated Outline Dimensions ....................................................... 21
Changes to Ordering Guide .......................................................... 23
8/2004—Rev. F to Rev. G
Changes to Figure 12...................................................................... 12
Changes to Reading Data from the AD7416/AD7417/AD7418
Section .............................................................................................. 13
Changes to Power-On-Reset section ........................................... 14
7/2003—Rev. E to Rev. F
Changes to Features Section ............................................................1
Changes to Specifications Section ...................................................3
Changes to Absolute Maximum Ratings Section ..........................6
Changes to Ordering Guide Section ...............................................6
Changes to Product Highlights Section .........................................7
Changes to Circuit Information Section ........................................7
Changes to Temperature Measurement Section............................9
10/2002—Rev. D to Rev. E
Changes to Specifications Headings ...............................................2
Added Temperature Measurement Section ...................................8
Changes to Serial Bus Address Section ....................................... 10
Changes to Figure 11...................................................................... 12
Changes to CONVST Pin Mode Section..................................... 14
Changes to Power-On-Reset Section ........................................... 14
Inserted Figure 16 and Figure 17; Renumbered Sequentially .. 15
Updated Outline Dimensions ....................................................... 16
Rev. J | Page 2 of 23
Data Sheet
AD7416/AD7417/AD7418
An I2C® compatible serial interface allows the AD7416/AD7417/
AD7418 registers to be written to and read back. The three
LSBs of the AD7416/AD7417 serial bus address can be selected,
which allows up to eight AD7416/AD7417 devices to be connected
to a single bus.
The AD7417 is available in a narrow body, 0.15 inch, 16-lead,
small outline package (SOIC) and in a 16-lead, thin shrink,
small outline package (TSSOP). The AD7416 and AD7418 are
available in 8-lead SOIC and MSOP packages.
PRODUCT HIGHLIGHTS
1.
2.
3.
The AD7416/AD7417/AD7418 have an on-chip temperature
sensor that allows an accurate measurement of the ambient
temperature (±1°C at 25°C, ±2°C overtemperature) to be
Rev. J | Page 3 of 23
made. The measurable temperature range is −40°C to
+125°C. An overtemperature indicator is implemented by
carrying out a digital comparison of the ADC code for
Channel 0 (temperature sensor) with the contents of the
on-chip TOTI setpoint register.
The AD7417 offers a space-saving, 10-bit analog-to-digital
solution with four external voltage input channels, an onchip temperature sensor, an on-chip reference, and a clock
oscillator.
The automatic power-down feature enables the AD7416/
AD7417/AD7418 to achieve superior power performance.
At slower throughput rates, the part can be programmed to
operate in a low power shutdown mode, allowing further
savings in power consumption.
AD7416/AD7417/AD7418
Data Sheet
SPECIFICATIONS
AD7417/AD7418 SPECIFICATIONS
VDD = 2.7 V to 5.5 V, GND = 0 V, REFIN = 2.5 V, unless otherwise noted.
Table 1.
Parameter
DC ACCURACY
Resolution
Minimum Resolution for Which No
Missing Codes Are Guaranteed
Relative Accuracy 2
Differential Nonlinearity2
Gain Error2
Gain Error Match2
Offset Error2
Offset Error Match2
ANALOG INPUTS
Input Voltage Range
Input Leakage Current 3
Input Capacitance
TEMPERATURE SENSOR1
Measurement Error
Ambient Temperature 25°C
TMIN to TMAX
Temperature Resolution
CONVERSION RATE
Track-and-Hold Acquisition Time 4
Conversion Time
Temperature Sensor
Channel 1 to Channel 4
REFERENCE INPUT 5,6
REFIN Input Voltage Range
Input Impedance
Input Capacitance
ON-CHIP REFERENCE
Reference Error6
Temperature Coefficient6
DIGITAL INPUTS
Input High Voltage, VIH
Input Low Voltage, VIL
Input Leakage Current
DIGITAL OUTPUTS
Output Low Voltage, VOL
Output High Current
A Version
B Version 1
Unit
Test Conditions/Comments
Any channel
10
10
10
10
Bits
Bits
±1
±1
±3
±10
±0.6
±4
±0.7
±1
±1
±3
±10
±0.6
±4
±0.7
LSB max
LSB max
LSB max
LSB max
LSB max
LSB max
LSB max
VREF
0
±1
10
VREF
0
±1
10
V max
V min
μA max
pF max
±2
±3
1/4
±1
±2
1/4
°C max
°C max
°C/LSB
400
400
ns max
Source impedance < 10 Ω
30
15
30
15
μs max
μs max
Typically 27 μs
Typically 10 μs
2.625
2.375
40
10
2.625
2.375
40
10
V max
V min
kΩ min
pF max
2.5 V + 5%
2.5 V − 5%
±25
80
±25
80
mV max
ppm/°C typ
VDD × 0.7
VDD × 0.3
1
VDD × 0.7
VDD × 0.3
1
V min
V max
μA max
0.4
1
0.4
1
V max
μA max
This specification is typical for VDD of 3.6 V to 5.5 V
This specification is typical for VDD of 3.6 V to 5.5 V
External reference
Internal reference
AD7417 only
AD7417 only
Nominal 2.5 V
Rev. J | Page 4 of 23
IOL = 3 mA
VOH = 5 V
Data Sheet
Parameter
POWER REQUIREMENTS
VDD
IDD
Normal Operation
Power-Down
Auto Power-Down Mode
10 SPS Throughput Rate
1 kSPS Throughput Rate
10 kSPS Throughput Rate
Power-Down
AD7416/AD7417/AD7418
A Version
B Version 1
Unit
Test Conditions/Comments
5.5
2.7
5.5
2.7
V max
V min
For specified performance
600
1.5
600
1.5
μA max
μA max
6
60
600
3
6
60
600
3
μW typ
μW typ
μW typ
μW max
Logic inputs = 0 V or VDD
0.7 µA typically
VDD = 3 V; see the Operating Modes section
Typically 0.15 μW
B Version applies to AD7417 only with temperature range of −40°C to +85°C. A Version temperature range is −40°C to +125°C. For VDD = 2.7 V, TA = 85°C maximum and
temperature sensor measurement error = ±3°C maximum.
2
See the Terminology section.
3
Refers to the input current when the part is not converting. Primarily due to reverse leakage current in the ESD protection diodes.
4
Sample tested during initial release and after any redesign or process change that may affect this parameter.
5
On-chip reference shuts down when an external reference is applied.
6
The accuracy of the temperature sensor is affected by reference tolerance.
1
Rev. J | Page 5 of 23
AD7416/AD7417/AD7418
Data Sheet
AD7416 SPECIFICATIONS
VDD = 2.7 V to 5.5 V, GND = 0 V, REFIN = 2.5 V, unless otherwise noted.
Table 2.
Parameter
TEMPERATURE SENSOR AND ADC
Accuracy
Min
Resolution
Temperature Conversion Time
Update Rate, tR
OTI Delay
Supply Current
Unit
Test Conditions/Comments
±2.0
°C
±3.0
°C
TA = −25°C to + 100°C
(VDD = 3 V minimum) 1
TA = −40°C to + 125°C
(VDD = 3 V minimum)1
40
400
1 × tR
350
0.2
80
75
VDD × 0.7
−0.3
+0.005
−0.005
20
6 × tR
1.0
600
1.5
Bits
μs
μs
ms
mA
μA
μA
°C
°C
VDD + 0.5
VDD × 0.3
+1.0
−1.0
V
V
μA
μA
pF
0.4
1
250
0.8
V
μA
ns
V
Depends on fault queue setting
I2C active
I2C inactive
Shutdown mode
VIN = 5 V
VIN = 0 V
All digital inputs
2.5
50
0
μs
ns
ns
IOL = 3 mA
VOH = 5 V
CL = 400 pF, IO = 3 mA
IOUT = 4 mA
AD7416/AD7417/AD7418
See Figure 4
See Figure 4
See Figure 4
50
ns
See Figure 4
ns
ns
See Figure 4
See Figure 4
50
300
For VDD = 2.7 V to 3 V, TA maximum = 85°C and temperature sensor measurement error = ±3°C maximum.
Sample tested during initial release and after any redesign or process change that may affect this parameter.
t1
SCL
t4
t2
t5
SDA
DATA IN
t3
SDA
DATA OUT
t6
Figure 4. Diagram for Serial Bus Timing
Rev. J | Page 6 of 23
01126-004
2
Max
10
TOTI Default Temperature
THYST Default Temperature
DIGITAL INPUTS
Input High Voltage, VIH
Input Low Voltage, VIL
Input High Current, IIH
Input Low Current, IIL
Input Capacitance, CIN
DIGITAL OUTPUTS
Output Low Voltage, VOL
Output High Current
Output Fall Time, tf
OS Output Low Voltage, VOL
AC ELECTRICAL CHARACTERISTICS 2
Serial Clock Period, t1
Data In Setup Time to SCL High, t2
Data Out Stable after SCL Low, t3
SDA Low Setup Time to SCL Low
(Start Condition), t4
SDA High Hold Time after SCL High
(Stop Condition), t5
SDA and SCL Fall Time, t6
1
Typ
Data Sheet
AD7416/AD7417/AD7418
ABSOLUTE MAXIMUM RATINGS
Table 3.
Parameter
VDD to AGND
VDD to DGND
Analog Input Voltage to AGND
AIN1 to AIN4
Reference Input Voltage to AGND1
Digital Input Voltage to DGND
Digital Output Voltage to DGND
Operating Temperature Range
A Version
B Version
Storage Temperature Range
Junction Temperature
TSSOP, Power Dissipation
θJA Thermal Impedance
Lead Temperature, Soldering
Vapor Phase (60 sec)
Infrared (15 sec)
16-Lead SOIC Package, Power Dissipation
θJA Thermal Impedance
Lead Temperature, Soldering
Vapor Phase (60 sec)
Infrared (15 sec)
8-Lead SOIC Package, Power Dissipation
θJA Thermal Impedance
Lead Temperature, Soldering
Vapor Phase (60 sec)
Infrared (15 sec)
MSOP Package, Power Dissipation
θJA Thermal Impedance
Lead Temperature, Soldering
Vapor Phase (60 sec)
Infrared (15 sec)
1
Rating
−0.3 V to +7 V
−0.3 V to +7 V
−0.3 V to VDD + 0.3 V
−0.3 V to VDD + 0.3 V
−0.3 V to VDD + 0.3 V
−0.3 V to VDD + 0.3 V
−40°C to +125°C
−40°C to +85°C
−65°C to +150°C
150°C
450 mW
120°C/W
260°C
215°C
220°C
450 mW
100°C/W
Stresses at or above those listed under Absolute Maximum
Ratings may cause permanent damage to the product. This is a
stress rating only; functional operation of the product at these
or any other conditions above those indicated in the operational
section of this specification is not implied. Operation beyond
the maximum operating conditions for extended periods may
affect product reliability.
VDD
REFIN
BAT81
AD7417
01126-025
TA = 25°C, unless otherwise noted.
Figure 5. Diode Connection
ESD CAUTION
215°C
220°C
450 mW
157°C/W
215°C
220°C
450 mW
206°C/W
215°C
220°C
If the reference input voltage is likely to exceed VDD by more than 0.3 V (for
example, during power-up) and the reference is capable of supplying 30 mA
or more, it is recommended to use a clamping diode between the REFIN pin
and the VDD pin. Figure 5 shows how the diode should be connected.
Rev. J | Page 7 of 23
AD7416/AD7417/AD7418
Data Sheet
PIN CONFIGURATIONS AND FUNCTION DESCRIPTIONS
NC 1
16
NC
SDA 2
15
CONVST
14
VDD
SCL 3
13 A0
TOP VIEW
REFIN 5 (Not to Scale) 12 A1
11 A2
GND 6
AIN1 7
10
AIN4
AIN2 8
9
AIN3
NC = NO CONNECT
01126-005
OTI 4
AD7417
Figure 6. AD7417 Pin Configuration (SOIC/TSSOP)
Table 4. AD7417 Pin Function Descriptions
Pin No.
1, 16
2
3
4
Mnemonic
NC
SDA
SCL
OTI
5
REFIN
6
7 to 10
GND
AIN1 to AIN4
11
12
13
14
15
A2
A1
A0
VDD
CONVST
Description
No Connection. Do not connect anything to this pin.
Digital I/O. Serial bus bidirectional data. Push-pull output.
Digital Input. Serial bus clock.
This pin is a logic output. The overtemperature indicator (OTI) is set if the result of a conversion on Channel 0
(temperature sensor) is greater than an 8-bit word in the TOTI setpoint register. The signal is reset at the end of a
serial read operation. Open-drain output.
Reference Input. An external 2.5 V reference can be connected to the AD7417 at this pin. To enable the on-chip
reference, the REFIN pin should be tied to GND. If an external reference is connected to the AD7417, the internal
reference shuts down.
Ground reference for track-and-hold, comparator and capacitor DAC, and digital circuitry.
Analog Input Channels. The AD7417 has four analog input channels. The input channels are single-ended with
respect to GND. The input channels can convert voltage signals in the range of 0 V to VREF. A channel is selected by
writing to the configuration register of the AD7417.
Digital Input. This is the highest programmable bit of the serial bus address.
Digital Input. This is the middle programmable bit of the serial bus address.
Digital Input. This is the lowest programmable bit of the serial bus address.
Positive Supply Voltage, 2.7 V to 5.5 V.
Logic Input Signal. Convert start signal. The rising edge of this signal fully powers up the part. The power-up time
for the part is 4 μs. If the CONVST pulse is greater than 4 μs, the falling edge of CONVST places the track-and-hold
mode into hold mode and initiates a conversion. If the pulse is less than 4 μs, an internal timer ensures that the
track-and-hold does not go into hold, and conversion is not initiated until the power-up time has elapsed. The
track-and-hold goes into track mode again at the end of conversion (see the Operating Modes section).
Rev. J | Page 8 of 23
AD7416/AD7417/AD7418
SDA 1
SCL 2
AD7416
OTI 3
TOP VIEW
GND 4 (Not to Scale)
8
VDD
7
A0
6
A1
5
A2
01126-006
Data Sheet
Figure 7. AD7416 Pin Configuration (SOIC/MSOP)
Table 5. AD7416 Pin Function Descriptions
Mnemonic
SDA
SCL
OTI
4
5
6
7
8
GND
A2
A1
A0
VDD
Description
Digital I/O. Serial bus bidirectional data. Push-pull output.
Digital Input. Serial bus clock.
This pin is a logic output. The OTI is set if the result of a conversion on Channel 0 (temperature sensor) is greater
than an 8-bit word in the TOTI setpoint register. The signal is reset at the end of a serial read operation. Open-drain
output.
Ground reference for track-and-hold, comparator and capacitor DAC, and digital circuitry.
Digital Input. This is the highest programmable bit of the serial bus address.
Digital Input. This is the middle programmable bit of the serial bus address.
Digital Input. This is the lowest programmable bit of the serial bus address.
Positive Supply Voltage, 2.7 V to 5.5 V.
SDA 1
SCL 2
OTI 3
AD7418
TOP VIEW
GND 4 (Not to Scale)
8
CONVST
7
VDD
6
REFIN
5
AIN
01126-007
Pin No.
1
2
3
Figure 8. AD7418 Pin Configuration (SOIC/MSOP)
Table 6. AD7418 Pin Function Descriptions
Pin No.
1
2
3
Mnemonic
SDA
SCL
OTI
4
5
GND
AIN
6
REFIN
7
8
VDD
CONVST
Description
Digital I/O. Serial bus bidirectional data. Push-pull output.
Digital Input. Serial bus clock.
This is a logic output. The OTI is set if the result of a conversion on Channel 0 (temperature sensor) is greater than
an 8-bit word in the TOTI setpoint register. The signal is reset at the end of a serial read operation. Open-drain
output.
Ground reference for track-and-hold, comparator and capacitor DAC, and digital circuitry.
Analog Input Channel. The input channel is single-ended with respect to GND. The input channel can convert
voltage signals in the range of 0 V to VREF. The analog input channel is selected by writing to the configuration
register of the AD7418 and choosing Channel 4.
Reference Input. An external 2.5 V reference can be connected to the AD7418 at this pin. To enable the on-chip
reference, the REFIN pin should be tied to GND. If an external reference is connected to the AD7418, the internal
reference shuts down.
Positive Supply Voltage, 2.7 V to 5.5 V.
Logic Input Signal. Convert start signal. The rising edge of this signal fully powers up the part. The power-up time
for the part is 4 μs. If the CONVST pulse is greater than 4 μs, the falling edge of CONVST places the track-and-hold
mode into hold mode and initiates a conversion. If the pulse is less than 4 μs, an internal timer ensures that the
track-and-hold does not go into hold, and conversion is not initiated until the power-up time has elapsed. The
track-and-hold goes into track mode again at the end of conversion (see the Operating Modes section).
Rev. J | Page 9 of 23
AD7416/AD7417/AD7418
Data Sheet
TERMINOLOGY
Relative Accuracy
Relative accuracy or endpoint nonlinearity is the maximum
deviation from a straight line passing through the endpoints of
the ADC transfer function.
Differential Nonlinearity
This is the difference between the measured and the ideal 1 LSB
change between any two adjacent codes in the ADC.
Offset Error
This is the deviation of the first code transition (0000…000) to
(0000…001) from the ideal, that is, GND + 1 LSB.
Offset Error Match
This is the difference in offset error between any two channels.
Gain Error
This is the deviation of the last code transition (1111…110) to
(1111…111) from the ideal, that is, VREF − 1 LSB, after the
offset error has been adjusted out.
Gain Error Match
This is the difference in gain error between any two channels.
Track-and-Hold Acquisition Time
Track-and-hold acquisition time is the time required for the
output of the track-and-hold amplifier to reach its final value,
within ±½ LSB, after the end of conversion (the point at which
the track-and-hold returns to track mode). It also applies to
situations where a change in the selected input channel takes
place or where there is a step input change on the input voltage
applied to the selected AIN input of the AD7417 or AD7418. It
means that the user must wait for the duration of the track-andhold acquisition time after the end of conversion, or after a
channel change or step input change to AIN before starting
another conversion, to ensure that the part operates to
specification.
Rev. J | Page 10 of 23
Data Sheet
AD7416/AD7417/AD7418
THEORY OF OPERATION
SUPPLY
2.7V TO 5.5V
+
A temperature measurement is made by selecting the Channel 0
of the on-chip mux and carrying out a conversion on this
channel. A conversion on Channel 0 takes 30 μs to complete.
Temperature measurement is explained in the Temperature
Measurement section.
TYPICAL CONNECTION DIAGRAM
Figure 9 shows a typical connection diagram for the AD7417.
Using the A0, A1, and A2 pins allows the user to select from up
to eight AD7417 devices on the same serial bus, if desired. An
external 2.5 V reference can be connected at the REFIN pin. If an
AIN1
AIN2
AIN3
0V TO 2.5V
INPUT
AIN4
SCL
SDA
CONVST
OTI
AD7417
GND
MICROCONTROLLER/
MICROPROCESSOR
A0
A1
A2
REFIN
OPTIONAL
EXTERNAL
REFERENCE
AD780/
REF192
10µF FOR
EXTERNAL
REFERENCE
Figure 9. Typical AD7417 Connection Diagram
ANALOG INPUTS
Figure 10 shows an equivalent circuit of the analog input
structure of the AD7417 and AD7418. The two diodes, D1
and D2, provide ESD protection for the analog inputs. Care
must be taken to ensure that the analog input signal never
exceeds the supply rails by more than 200 mV to prevent these
diodes from becoming forward-biased and start conducting
current into the substrate. The maximum current these diodes
can conduct without causing irreversible damage to the part is
20 mA. Capacitor C2 in Figure 10 is typically about 4 pF and
can primarily be attributed to pin capacitance. Resistor R1 is a
lumped component made up of the on resistance of a multiplexer
and a switch. This resistor is typically about 1 kΩ. Capacitor C1
is the ADC sampling capacitor and has a capacitance of 3 pF.
VDD
D1
R1
1kΩ
C1
3pF
VBALANCE
AIN
C2
4pF
The on-chip reference is not available to the user, but REFIN can
be overdriven by an external reference source (2.5 V only).
All unused analog inputs should be tied to a voltage within the
nominal analog input range to avoid noise pickup. For
minimum power consumption, the unused analog inputs
should be tied to GND.
2-WIRE
SERIAL
INTERFACE
0.1µF
VDD
CONVERTER DETAILS
Conversion is initiated on the AD7417/AD7418 by pulsing the
CONVST input. The conversion clock for the part is internally
generated so that no external clock is required except when
reading from and writing to the serial port. The on-chip trackand-hold goes from track mode to hold mode, and the conversion
sequence is started on the falling edge of the CONVST signal.
A conversion is also initiated in the automatic conversion mode
every time a read or write operation to the AD7416/AD7417/
AD7418 takes place. In this case, the internal clock oscillator
(which runs the automatic conversion sequence) is restarted
at the end of the read or write operation. The track-and-hold
goes into hold mode approximately 3 μs after the read or write
operation is complete, and a conversion is then initiated. The
result of the conversion is available either 15 μs or 30 μs later,
depending on whether an analog input channel or the temperature sensor is selected. The track-and-hold acquisition time of
the AD7417/AD7418 is 400 ns.
+
10µF
01126-008
The AD7417 and AD7418 are single-channel and four-channel,
15 μs conversion time, 10-bit ADCs with on-chip temperature
sensor, reference, and serial interface logic functions on a single
chip. The AD7416 has no analog input channel and is intended
for temperature measurement only. The ADC section consists
of a conventional successive approximation converter based
around a capacitor DAC. The AD7416, AD7417, and AD7418
are capable of running on a 2.7 V to 5.5 V power supply, and the
AD7417 and AD7418 accept an analog input range of 0 V to
+VREF. The on-chip temperature sensor allows an accurate
measurement of the ambient device temperature to be made.
The working measurement range of the temperature sensor is
−40°C to +125°C. The parts require a 2.5 V reference that can
be provided from the part’s own internal reference or from an
external reference source.
external reference is used, a 10 μF capacitor should be connected
between REFIN and GND. SDA and SCL form the 2-wire I2C
compatible interface. For applications where power consumption is of concern, the automatic power-down at the end of a
conversion should be used to improve power performance (see
the Operating Modes section.)
D2
CONVERT PHASE: SWITCH OPEN
TRACK PHASE: SWITCH CLOSED
01126-009
CIRCUIT INFORMATION
Figure 10. Equivalent Analog Input Circuit
ON-CHIP REFERENCE
The AD7417/AD7418 have an on-chip 1.2 V band gap reference
that is amplified by a switched capacitor amplifier to give an
output of 2.5 V. The amplifier is only powered up at the start of
the conversion phase and is powered down at the end of the
conversion. The on-chip reference is selected by connecting the
REFIN pin to analog ground, which causes SW1 (see Figure 11) to
open and the reference amplifier to power up during a conversion. Therefore, the on-chip reference is not available externally.
Rev. J | Page 11 of 23
AD7416/AD7417/AD7418
Data Sheet
An external 2.5 V reference can be connected to the REFIN pin.
This has the effect of shutting down the on-chip reference
circuitry.
REFIN
The temperature resolution of the ADC is 0.25°C, which corresponds to 1 LSB of the ADC. The ADC can theoretically measure a
temperature span of 255°C; the guaranteed temperature range is
−40°C to +125°C. The result of the conversion is stored in the
temperature value register (0x00) as a 16-bit word. The 10 MSBs
of this word store the temperature measurement (see Table 9
and Table 10).
EXTERNAL
REFERENCE
DETECT
1.2V
The temperature conversion formulas using the 10 MSBs of the
temperature value register are
SW1
1.2V
2.5V
BUFFER
(1)
Negative Temperature = (ADC Code − 512)/4
(2)
The MSB is removed from ADC Code in Equation 2.
01126-010
24kΩ
Positive Temperature = ADC Code/4
INTERNAL REGISTER STRUCTURE
Figure 11. On-Chip Reference
TEMPERATURE MEASUREMENT
A common method of measuring temperature is to exploit the
negative temperature coefficient of a diode, or the base-emitter
voltage of a transistor, operated at a constant current. Unfortunately, this technique requires calibration to null out the effect
of the absolute value of VBE, which varies from device to device.
The AD7417/AD7418 have seven internal registers, as shown in
Figure 13. Six of these are data registers and one is an address
pointer register. The AD7416 has five internal registers (the
ADC and Config2 registers are not applicable to the AD7416).
TEMPERATURE
VALUE
REGISTER
(READ-ONLY
ADDRESS 0x00)
The technique used in the AD7416/AD7417/AD7418 is to
measure the current change in VBE when the device is operated
at two different currents.
CONFIGURATION
REGISTER
(READ/WRITE
ADDRESS 0x01)
This is given by
THYST SETPOINT
REGISTER
(READ/WRITE
ADDRESS 0x02)
ADDRESS POINTER
REGISTER
(SELCTS DATA REGISTER
FOR READ/WRITE)
VBE KT / q 1nN
where:
K is Boltzmann’s constant.
q is the charge on the electron (1.6 × 10−19 Coulombs).
T is the absolute temperature in Kelvins.
N is the ratio of the two currents.
TOTI SETPOINT
REGISTER
(READ/WRITE
ADDRESS 0x03)
ADDRESS
ADC VALUE
REGISTER
(READ-ONLY
ADDRESS 0x04)
I
DATA
CONFIG2
REGISTER
(READ/WRITE
ADDRESS 0x05)
VDD
N×I
SDA
SCL
SERIAL BUS INTERFACE
Figure 13. AD7417/AD7418 Register Structure
VOUT+
Address Pointer Register
TO ADC
SENSING
TRANSISTOR
01126-011
VOUT–
SENSING
TRANSISTOR
01126-012
26kΩ
Figure 12. Temperature Measurement Technique
Figure 12 shows the method the AD7416/AD7417/AD7418 use
to measure the device temperature. To measure ΔVBE, the
sensor (substrate transistor) is switched between operating
currents of I and N × I. The resulting waveform is passed through
a chopper-stabilized amplifier that performs the functions of
amplification and rectification of the waveform to produce a dc
voltage proportional to ΔVBE. This voltage is measured by the ADC
to give a temperature output in 10-bit twos complement form.
The address pointer register is an 8-bit register that stores an
address that points to one of the six data registers. The first data
byte of every serial write operation to the AD7416/AD7417/
AD7418 is the address of one of the data registers, which is
stored in the address pointer register, and selects the data
register to which subsequent data bytes are written. Only the
three LSBs of the address pointer register are used to select a
data register.
Table 7. Address Pointer Register
P71
0
1
P61
0
P51
0
P3 to P7 must be set to 0.
Rev. J | Page 12 of 23
P41
0
P31
0
P2
P1
P0
Register select
Data Sheet
AD7416/AD7417/AD7418
The AD7416 contains a temperature-only channel; the AD7417
has four analog input channels and a temperature channel; and
the AD7418 has two channels, a temperature channel, and an
analog input channel. The temperature channel address for all
parts is the same, Channel 0. The address for the analog input
channel on the AD7418 is Channel 4. Table 12 outlines the
channel selection on the parts, and Table 13 shows the fault
queue settings. D1 and D2 are explained in the OTI Output
section.
Table 8. Register Addresses
P2
0
0
0
0
1
1
P1
0
0
1
1
0
0
P0
0
1
0
1
0
1
Registers
Temperature value
Configuration register
THYST setpoint
TOTI setpoint
ADC value (AD7417/AD7418 only)
Config2 (AD7417/AD7418 only)
Temperature Value Register (Address 0x00)
The temperature value register is a 16-bit, read-only register
whose 10 MSBs store the temperature reading from the ADC in
10-bit twos complement format. Bit D5 to Bit D0 are unused.
Table 9. Temperature Value Register
D15
MSB
D14
B8
D13
B7
D12
B6
D11
B5
D10
B4
D9
B3
D8
B2
D7
B1
D6
LSB
The temperature data format is shown in Table 10. This shows
the full theoretical range of the ADC from −128°C to +127°C,
but in practice, the temperature measurement range is limited
to the operating temperature range of the device.
Table 10. Temperature Data Format
Temperature
−128°C
−125°C
−100°C
−75°C
−50°C
−25°C
−10°C
−0.25°C
0°C
+0.25°C
+10°C
+25°C
+50°C
+75°C
+100°C
+125°C
+127°C
Digital Output
10 0000 0000
10 0000 1100
10 0111 0000
10 1101 0100
11 0011 1000
11 1001 1100
11 1101 1000
11 1111 1111
00 0000 0000
00 0000 0001
00 0010 1000
00 0110 0100
00 1100 1000
01 0010 1100
01 1001 0000
01 1111 0100
01 1111 1100
D2
OTI
polarity
D1
Cmp/Int
D5
0
1
0
1
0
Channel Selection
Temperature sensor (all parts), Channel 0
AIN1 (AD7417 only), Channel 1
AIN2 (AD7417 only), Channel 2
AIN3 (AD7417 only), Channel 3
AIN4 (AD7417) and AIN (AD7418), Channel 4
Table 13. Fault Queue Settings
D4
0
0
1
1
D3
0
1
0
1
Number of Faults
1 (power-up default)
2
4
6
TOTI Setpoint Register (Address 0x03)
The TOTI setpoint register is a 16-bit, read/write register whose
nine MSBs store the TOTI setpoint in twos complement format
equivalent to the nine MSBs of the temperature value register.
Bit 6 to Bit 0 are unused.
Table 14. THYST Setpoint and TOTI Setpoint Registers
D15
MSB
D14
B7
D13
B6
D12
B5
D11
B4
D10
B3
D9
B2
D8
B1
D7
LSB
ADC Value Register (Address 0x04)
Table 11. Configuration Register
D4 D3
Fault
queue
D6
0
0
1
1
0
The THYST setpoint register is a 16-bit, read/write register whose
nine MSBs store the THYST setpoint in twos complement format
equivalent to the nine MSBs of the temperature value register.
Bit D6 to Bit D0 are unused.
The configuration register is an 8-bit, read/write register that is
used to set the operating modes of the AD7416/AD7417/AD7418.
Bit D7 to Bit D5 control the channel selection as outlined in
Table 12. Bits[D7:D5] should always be set to 000 for the AD7416.
Bit D4 and Bit D3 are used to set the length of the fault queue.
D2 sets the sense of the OTI output. D1 selects the comparator
or interrupt mode of operation, and D0 = 1 selects the shutdown
mode (default: D0 = 0).
D6 D5
Channel
selection
D7
0
0
0
0
1
THYST Setpoint Register (Address 0x02)
Configuration Register (Address 0x01)
D7
Table 12. Channel Selection
D0
Shutdown
The ADC value register is a 16-bit, read-only register whose
10 MSBs store the value produced by the ADC in binary format.
Bit D5 to Bit D0 are unused. Table 15 shows the ADC value
register with 10 MSBs containing the ADC conversion request.
Table 15. ADC Value Register
D15
MSB
D14
B8
D13
B7
D12
B6
D11
B5
D10
B4
D9
B3
D8
B2
D7
B1
D6
LSB
ADC Transfer Function
The designed code transitions occur at successive integer
LSB values (that is, 1 LSB, 2 LSB, and so on). The LSB size =
VREF/1024. The ideal transfer function characteristic for the
AD7417 and AD7418 ADC is shown in Figure 14.
Rev. J | Page 13 of 23
AD7416/AD7417/AD7418
Data Sheet
ADC CODE
111...111
111...110
111...000
1LSB – VREF/1024
011...111
000...010
000...001
0V 1/2LSB
01126-013
000...000
+VREF – 1LSB
ANALOG INPUT
2.
Figure 14. Ideal Transfer Function Characteristic for the AD7417/AD7418
Config2 Register (Address 0x05)
A second configuration register is included in the AD7417/
AD7418 for the functionality of the CONVST pin. It is an 8-bit
register with Bit D5 to Bit D0 being left at 0. Bit D7 determines
whether the AD7417/AD7418 should be operated in its default
mode (D7 = 0), performing conversions every 355 μs or in its
CONVST pin mode (D7 = 1), where conversions start only
when the CONVST pin is used. Bit 6 contains the Test 1 bit.
When this bit is 0, the I2C filters are enabled (default). Setting
this bit to 1 disables the filters.
3.
Table 16. Config2 Register
D7
Conversion mode
D6
Test 1
D5
0
D4
0
D3
0
D2
0
D1
0
D0
0
SERIAL BUS INTERFACE
Control of the AD7416/AD7417/AD7418 is carried out via the
I2C compatible serial bus. The AD7416/AD7417/AD7418 are
connected to this bus as a slave device, under the control of a
master device, for example, the processor.
Serial Bus Address
As with all I2C compatible devices, the AD7416/AD7417/AD7418
have a 7-bit serial address. The four MSBs of this address for the
AD7416 are set to 1001; the AD7417 are set to 0101, and the
three LSBs can be set by the user by connecting the A2 to A0
pins to either VDD or GND. By giving them different addresses,
up to eight AD7416/AD7417 devices can be connected to a
single serial bus, or the addresses can be set to avoid conflicts
with other devices on the bus. The four MSBs of this address for
the AD7418 are set to 0101, and the three LSBs are all set to 0.
Any number of bytes of data can be transferred over the serial
bus in one operation, but it is not possible to mix read and write
in one operation because the type of operation is determined at
the beginning and cannot subsequently be changed without
starting a new operation.
Writing to the AD7416/AD7417/AD7418
Depending on the register being written to, there are three
different writes for the AD7416/AD7417/AD7418.
•
•
If a serial communication occurs during a conversion operation,
the conversion stops and restarts after the communication.
The serial bus protocol operates as follows:
1.
direction of the data transfer, that is, whether data is written
to or read from the slave device.
The peripheral whose address corresponds to the transmitted
address responds by pulling the data line low during the low
period before the ninth clock pulse, known as the acknowledge bit. All other devices on the bus now remain idle while
the selected device waits for data to be read from or written
to it. If the R/W bit is a 0, then the master writes to the
slave device. If the R/W bit is a 1, then the master reads
from the slave device.
Data is sent over the serial bus in sequences of nine clock
pulses, eight bits of data followed by an acknowledge bit
from the receiver of data. Transitions on the data line must
occur during the low period of the clock signal and remain
stable during the high period, because a low-to-high transition when the clock is high may be interpreted as a stop signal.
When all data bytes have been read or written, stop
conditions are established. In write mode, the master pulls
the data line high during the 10th clock pulse to assert a
stop condition. In read mode, the master device pulls the
data line high during the low period before the ninth clock
pulse. This is known as no acknowledge. The master then
takes the data line low during the low period before the
10th clock pulse, then high during the 10th clock pulse to
assert a stop condition.
The master initiates data transfer by establishing a start condition, defined as a high-to-low transition on the serial data
line, SDA, while the serial clock line, SCL, remains high.
This indicates that an address/data stream follows. All slave
peripherals connected to the serial bus respond to the 7-bit
address (MSB first) plus an R/W bit, which determines the
Rev. J | Page 14 of 23
Writing to the address pointer register for a subsequent read.
To read data from a particular register, the address pointer
register must contain the address of that register. If it does
not, the correct address must be written to the address pointer
register by performing a single-byte write operation, as shown
in Figure 15. The write operation consists of the serial bus
address followed by the address pointer byte. No data is
written to any of the data registers.
Writing a single byte of data to the configuration register, the
Config2 register, or to the TOTI setpoint or THYST setpoint
registers.
The configuration register is an 8-bit register, so only one
byte of data can be written to it. If only 8-bit temperature
comparisons are required, the temperature LSB can be
ignored in TOTI and THYST, and only eight bits need to be
written to the TOTI setpoint and THYST setpoint registers.
Writing a single byte of data to one of these registers consists
of the serial bus address, the data register address written
to the address pointer register, followed by the data byte
Data Sheet
written to the selected data register. This is illustrated in
Figure 16.
Writing two bytes of data to the TOTI setpoint or THYST
setpoint register.
If 9-bit resolution is required for the temperature setpoints,
two bytes of data must be written to the TOTI setpoint and
1
THYST setpoint registers. This consists of the serial bus
address, the register address written to the address pointer
register, followed by two data bytes written to the selected
data register. This is illustrated in Figure 17.
9
1
9
SCL
1
0
0
1
A2
A1
A0
R/W
START BY
MASTER
P7
P6
P5
P3
P2
P1
P0
ACK. BY
AD741x 1
FRAME 1
SERIAL BUS ADDRESS BYTE
1AD741x
P4
ACK. BY
AD741x 1
FRAME 2
ADDRESS POINTER REGISTER BYTE
STOP
BY
MASTER
01126-014
SDA
= AD7416/AD7417/AD7418.
Figure 15. Writing to the Address Pointer Register to Select a Data Register for a Subsequent Read Operation
9
1
9
1
SCL
1
SDA
0
0
A1
A2
1
R/W
A0
P7
P6
P5
P4
P3
P2
P1
P0
ACK. BY
AD741x 1
ACK. BY
AD741x 1
START BY
MASTER
FRAME 1
SERIAL BUS ADDRESS BYTE
FRAME 2
ADDRESS POINTER REGISTER BYTE
9
1
SCL (CONTINUED)
SDA (CONTINUED)
D7
D6
D5
D4
D3
D2
D1
STOP
BY
MASTER
D0
01126-015
ACK. BY
AD741x 1
FRAME 3
DATA BYTE
1AD741x = AD7416/AD7417/AD7418.
Figure 16. Writing to the Address Pointer Register Followed by a Single Byte of Data to the Selected Data Register
1
9
1
9
SCL
SDA
1
0
0
1
A2
A1
A0
R/W
START BY
MASTER
P7
P6
P5
P4
P3
P2
P1
P0
ACK. BY
AD741x 1
ACK. BY
AD741x 1
FRAME 1
SERIAL BUS ADDRESS BYTE
FRAME 2
ADDRESS POINTER REGISTER BYTE
1
9
1
9
SCL
(CONTINUED)
SDA
(CONTINUED)
D15
D14
D13
D12
D11
D10
D9
D8
D7
D6
D5
D4
D3
D2
D1
FRAME 3
MOST SIGNIFICANT DATA BYTE
1AD741x
D0
STOP
BY
ACK. BY
AD741x 1 MASTER
ACK. BY STOP BY
AD741x 1 MASTER
FRAME 4
LEAST SIGNIFICANT DATA BYTE
= AD7416/AD7417/AD7418.
Figure 17. Writing to the Address Pointer Register Followed by Two Bytes of Data to the TOTI Setpoint or THYST Setpoint Register
Rev. J | Page 15 of 23
01126-016
•
AD7416/AD7417/AD7418
AD7416/AD7417/AD7418
Data Sheet
Reading Data From the AD7416/AD7417/AD7418
Note that when reading back from the AD7416/AD7417/
AD7418, no more than three bytes of data must be read back.
A stop command must be inserted at the end of the read
communication. If a stop command is not inserted by the
master and the AD7416/AD7417/AD7418 receive more SCL
cycles than the maximum needed for three bytes of data, then
the I2C interface on the AD7416/AD7417/AD7418 pulls the
SDA line low and prevents it from going high again. To recover
the AD7416/AD7417/AD7418 interface, the part must be
powered off and on again. Reference the AN-686 Application
Note, Implementing an I2C® Reset at www.analog.com for more
information on I2C interfaces.
Reading data from the AD7416/AD7417/AD7418 is a singlebyte or 2-byte operation. Reading back the contents of the
configuration register is a single-byte read operation, as shown
in Figure 18, with the register address previously having been
set by a single-byte write operation to the address pointer
register.
Reading data from the temperature value register, the TOTI
setpoint or THYST setpoint register is a 2-byte operation, as
shown in Figure 19. It is also possible to read the most
significant bit of a 9-bit or 10-bit register in this manner.
9
1
9
1
SCL
0
1
1
0
A1
A2
A0
D7
R/W
START BY
MASTER
D6
D5
D3
D2
D0
D1
NO ACK. BY STOP
BY
MASTER
MASTER
FRAME 2
SINGLE DATA BYTE FROM AD741x 1
FRAME 1
SERIAL BUS ADDRESS BYTE
1AD741x
D4
ACK. BY
AD741x 1
= AD7416/AD7417/AD7418.
Figure 18. Reading a Single Byte of Data from the Configuration Register
9
1
9
1
SCL
1
SDA
0
0
1
A2
A1
A0
START BY
MASTER
R/W
D15
D14
D13
D12
D11
D10
D9
D8
ACK. BY
MASTER
ACK. BY
AD741x 1
FRAME 1
SERIAL BUS ADDRESS BYTE
FRAME 2
MOST SIGNIFICANT BYTE FROM AD741x 1
1
9
SDA (CONTINUED)
D7
D6
D5
D4
D3
D2
D1
D0
FRAME 3
LEAST SIGNIFICANT DATA BYTE FROM AD741x 1
1AD741x
= AD7416/AD7417/AD7418.
Figure 19. Reading Two Bytes of Data from the TOTI Setpoint or THYST Setpoint Register
Rev. J | Page 16 of 23
STOP
BY
NO ACK. BY MASTER
MASTER
01126-018
SCL (CONTINUED)
01126-017
SDA
Data Sheet
AD7416/AD7417/AD7418
OTI OUTPUT
FAULT QUEUE
The OTI output has two operating modes that are selected by
Bit D1 of the configuration register. In the comparator mode,
(D1 = 0), the OTI output becomes active when the temperature
exceeds TOTI and remains active until the temperature falls
below THYST. This mode allows the AD7416/AD7417/AD7418 to
be used as a thermostat, for example, to control the operation of
a cooling fan.
To avoid false triggering of the AD7416/AD7417/AD7418 in
noisy environments, a fault queue counter is provided that can
be programmed by Bit D3 and Bit D4 of the configuration
register (see Table 11) to count 1, 2, 4, or 6 fault events before
OTI becomes active. To trigger OTI, the faults must occur
consecutively. For example, if the fault queue is set to 4, then
four consecutive temperature measurements greater than TOTI
(or less than THYST) must occur. Any reading that breaks the
sequence resets the fault queue counter, so if there are three
readings greater than TOTI followed by a reading less than TOTI,
the fault queue counter is reset without triggering OTI.
TOTI
THYST
OTI OUTPUT
COMPARATOR
MODE
POWER-ON DEFAULTS
The AD7416/AD7417/AD7418 always power up with the
following defaults:
OTI OUTPUT
INTERRUPT
MODE
INTERRUPT MODE, A READ OPERATION OR SHUTDOWN RESETS THE OTI
OUTPUT; OTHERWISE, THE OTI OUTPUT REMAINS ACTIVE INDEFINITELY,
ONCE TRIGGERED.
01126-019
READ1 READ1 READ1 READ1 READ1 READ1 READ1
1IN
Figure 20. Operation of OTI Output (Shown Active Low)
The open-drain configuration of OTI allows the OTI outputs of
several AD7416/AD7417/AD7418 devices to be wire-AND’ed
together when in active low mode.
The OTI output is used to indicate that an out-of-limit temperature excursion has occurred. OTI is an open-drain output that
can be programmed to be active low by setting Bit D2 of the
configuration register to 0 or active high by setting Bit D2 of
the configuration register to 1.
In the interrupt mode (D1 = 1), the OTI output becomes active
when the temperature exceeds TOTI and remains active even if
the temperature falls below THYST, until it is reset by a read operation. Once OTI becomes active by the temperature exceeding
TOTI, and resets, it remains inactive even if the temperature
remains, or subsequently rises again, above TOTI. It does not
become active again until the temperature falls below THYST. It
then remains active until reset by a read operation. Once OTI
becomes active by the temperature falling below THYST and then
resets, it remains inactive even if the temperature remains, or
subsequently falls again, below THYST.
OTI is also reset when the AD7416/AD7417/AD7418 are placed
in shutdown mode by setting Bit D0 of the configuration
register to 1.
The OTI output requires an external pull-up resistor. This can
be connected to a voltage different from VDD (for example, to
allow interfacing between 5 V and 3.3 V systems) provided that
the maximum voltage rating of the OTI output is not exceeded.
The value of the pull-up resistor depends on the application but
should be as large as possible to avoid excessive sink currents at
the OTI output, which can heat the chip and affect the temperature
reading. The maximum value of the pull-up resistor that meets
the output high current specification of the OTI output is 30 kΩ,
but higher values can be used if a lower output current is
required. For most applications, a value of 10 kΩ is suitable.
•
•
•
•
•
Address pointer pointing to temperature value register
comparator mode
TOTI = 80°C
THYST = 75°C
OTI active low
Fault queue = 1
These default settings allow the AD7416/AD7417/AD7418 to
be used as a standalone thermostat without any connection to a
serial bus.
OPERATING MODES
The AD7416/AD7417/AD7418 have two possible modes of
operation depending on the value of D0 in the configuration
register.
Mode 1
Normal operation of the AD7416/AD7417/AD7418 occurs
when D0 = 0. In this active mode, a conversion takes place
every 400 μs. After the conversion has taken place, the part
partially powers down, consuming typically 350 μA of the
current until the next conversion occurs.
Two situations can arise in this mode on the request of a temperature read. If a read occurs during a conversion, the conversion
aborts and a new one starts on the stop/repeat start condition.
The temperature value that is read is that of the previous completed conversion. The next conversion typically occurs 400 μs
after the new conversion has begun.
If a read is called between conversions, a conversion is initiated
on the stop/repeat start condition. After this conversion, the
part returns to performing a conversion every 400 μs.
With VDD = 3 V for each 400 μs cycle, the AD7416/AD7417/
AD7418 spend 40 μs (or 10% of the time) in conversion mode.
The part spends 360 μs (or 90% of time) in partial power-down
mode. Thus, the average power dissipated by the AD7416/
AD7417/AD7418 is
3 mW × 0.1 + 1 mW × 0.9 = 1.2 mW
Rev. J | Page 17 of 23
AD7416/AD7417/AD7418
Data Sheet
Mode 2
CONVST Pin Mode
For applications where temperature measurements are required
at a slower rate, for example, every second, power consumption
of the part can be reduced by writing to the part to go to a full
power-down between reads. The current consumption in full
power-down is typically 0.2 μA and full power-down is initiated
when D0 = 1 in the configuration register. When a measurement is
required, a write operation can be performed to power up the
part. The part then performs a conversion and is returned to
power-down. The temperature value can be read in full powerdown because the I2C bus is continuously active.
Conversions are initiated only by using the CONVST pin. In
this method of operation, CONVST is normally low.
Thus, the average power dissipation is
3 mW × 0.004 + 60 nW × 0.9996 = 1.2 μW
The CONVST pin should not be pulsed when reading from or
writing to the port.
Figure 21 shows the recommended minimum times for the
CONVST pulse when the temperature channel is selected.
Figure 22 shows the minimum times an analog input channel is
selected.
The fastest throughput rate at which the AD7416/AD7417/
AD7418 can be operated is 2.5 kHz (that is, a read every 400 μs
conversion period). Because TOTI and THYST are 2-byte reads, the
read time with the I2C operating at 100 kbps would be 270 μs. If
temperature reads are called too often, reads will overlap with
conversions, aborting them continuously, which results in
invalid readings.
100ns
CONVST
40µs
01126-023
The power dissipation in this mode depends on the rate at which
reads take place. Taking the requirements for a temperature
measurement every 100 ms as an example, the optimum power
dissipation is achieved by placing the part in full power-down,
waking it up every 100 ms, letting it operate for 400 μs and
putting it into full power-down again. In this case, the average
power consumption is calculated as follows. The part spends
40 μs (or 0.04% of time) converting with 3 mW dissipation
and a 99.96 ms (99.96% of time) in full shutdown with 60 nW
dissipation.
The rising edge of CONVST starts the power-up time. This
power-up time is 4 μs. If the CONVST high time is longer than
4 μs, a conversion is initiated on the falling edge of CONVST
and the track-and-hold also enters its hold mode at this time.
If the CONVST high time is less than 4 μs, an internal timer,
initiated by the rising edge of CONVST, holds off the trackand-hold and the initiation of conversion until the timer times
out (4 μs after the rising edge of CONVST, which corresponds
with the power-up time). The CONVST input remains low at
the end of conversion, thus causing the part to enter its powerdown mode. In this method of operation, CONVST is normally
low with a high going pulse controlling the power-up, and the
conversion starts.
Figure 21. CONVST When Temperature Channel Selected
CONVST START MODE
100ns
CONVST
15µs
Figure 22. CONVST When VIN Channel Selected
Rev. J | Page 18 of 23
01126-024
The AD7417/AD7418 have an extra mode, set by writing to the
MSB of the Config2 register.
Data Sheet
AD7416/AD7417/AD7418
APPLICATIONS INFORMATION
SUPPLY DECOUPLING
FAN CONTROLLER
The AD7416/AD7417/AD7418 should be decoupled with a
0.1 μF ceramic capacitor between VDD and GND. This is
particularly important if the part is mounted remote from the
power supply.
Figure 23 shows a simple fan controller that switches on a
cooling fan when the temperature exceeds 80°C and switches it
off again when the temperature falls below 75°C. The AD7416
can be used as a standalone device in this application or with a
serial bus interface if different trip temperatures are required. If the
AD7416 is used with a bus interface, the sense of OTI can be set
to active high, Q1 and R1 can be omitted, and OTI can be connected directly to the gate of Q2, with R2 as the pull-up resistor.
POWER-ON RESET
To ensure proper power-on reset, make sure that the supply
voltage on the VDD pin is at 0 V. Refer to the AN-588 Application
Note, AD7416/AD7417/AD7418 Power-On Reset Circuit at
www.analog.com for more information. A failed power-on reset
can prevent the default values from being loaded into the AD7416/
AD7417/AD7418 registers. If the correct values are not loaded
into the registers, then the device cannot start operating. The
output from the temperature value and ADC value registers will
be a constant value.
12V
VDD
3V TO 5.5V
R1
10kΩ
8
To restart the device operation, the registers have to be loaded
with their default values via the I2C bus. Therefore, in the event
of an inadequate power-on reset and for all three devices, the
following registers should be loaded with their default values:
Q1
2N3904
OR SIMILAR
01126-020
3
4
Configuration register—default value = 0x00
Config2 register—default value = 0x00
THYST setpoint register—default value = 0x4B00
TOTI setpoint register—default value = 0x5500
Figure 23. AD7416 Used as a Fan Controller
THERMOSTAT
MOUNTING THE AD7416/AD7417/AD7418
The AD7416/AD7417/AD7418 can be used for surface or air
temperature sensing applications. If the device is cemented to a
surface with thermally conductive adhesive, the die temperature
is within about 0.2°C of the surface temperature, due to the low
power consumption of the device. Take care to insulate the back
and leads of the device from the air if the ambient air
temperature is different from the surface temperature being
measured.
Figure 24 shows the AD7416 used as a thermostat. The heater
switches on when the temperature falls below THYST and
switches off again when the temperature rises above TOTI. For
this application and for comparator mode, program the OTI
output active low.
The GND pin provides the best thermal path to the die, so the
temperature of the die is close to that of the printed circuit
ground track. Take care to ensure that this is in close thermal
contact with the surface being measured.
As with any IC, the AD7416/AD7417/AD7418 and its associated
wiring and circuits must be kept free from moisture to prevent
leakage and corrosion, particularly in cold conditions where
condensation is more likely to occur. Water resistant varnishes
and conformal coatings can be used for protection. The small
size of the AD7416 package allows it to be mounted inside sealed
metal probes that provide a safe environment for the device.
Rev. J | Page 19 of 23
VDD
3V TO 5.5V
HEATER
R1
10kΩ
8
AD7416
3
RELAY
D1
1N4001
RLA1
Q1
2N3904
OR SIMILAR
HEATER
SUPLY
01126-021
AD7416
Q2
LOGIC LEVEL
MOSFET RATED
TO SUIT FAN
CURRENT
R2
10kΩ
4
Figure 24. AD7416 Used as a Thermostat
AD7416/AD7417/AD7418
Data Sheet
SYSTEM WITH MULTIPLE AD7416 DEVICES
line. This arrangement means that each device must be read to
determine which one has generated the interrupt, and if a
unique interrupt is required for each device, the OTI outputs
can be connected separately to the I/O chip.
The three LSBs of the AD7416 serial address can be set by the
user, allowing eight different addresses from 1001000 to
1001111. Figure 25 shows a system in which eight AD7416
devices are connected to a single serial bus, with their OTI
outputs wire-AND’ed together to form a common interrupt
R1
10kΩ
4
1
5
4
2
6
1
5
4
8
3
7
2
6
1
5
8
3
7
2
6
1
5
4
4
8
3
7
2
6
1
5
8
4
Figure 25. Multiple Connection of AD7416 Devices to a Single Serial Bus
Rev. J | Page 20 of 23
3
7
2
6
1
5
4
AD7416
5
6
7
AD7416
1
2
8
3
AD7416
6
7
AD7416
2
8
3
3
2
1
01126-022
4
7
AD7416
5
3
AD7416
6
8
AD7416
7
AD7416
8
PROCESSOR
SUPER I/O CHIP
VDD
3V TO
5.5V
Data Sheet
AD7416/AD7417/AD7418
OUTLINE DIMENSIONS
10.00 (0.3937)
9.80 (0.3858)
4.00 (0.1575)
3.80 (0.1496)
9
16
1
8
1.27 (0.0500)
BSC
0.50 (0.0197)
0.25 (0.0098)
1.75 (0.0689)
1.35 (0.0531)
0.25 (0.0098)
0.10 (0.0039)
COPLANARITY
0.10
6.20 (0.2441)
5.80 (0.2283)
SEATING
PLANE
0.51 (0.0201)
0.31 (0.0122)
45°
8°
0°
0.25 (0.0098)
0.17 (0.0067)
1.27 (0.0500)
0.40 (0.0157)
COMPLIANT TO JEDEC STANDARDS MS-012-AC
060606-A
CONTROLLING DIMENSIONS ARE IN MILLIMETERS; INCH DIMENSIONS
(IN PARENTHESES) ARE ROUNDED-OFF MILLIMETER EQUIVALENTS FOR
REFERENCE ONLY AND ARE NOT APPROPRIATE FOR USE IN DESIGN.
Figure 26. 16-Lead Standard Small Outline Package [SOIC_N]
Narrow Body
(R-16)
Dimensions shown in millimeters and (inches)
5.00 (0.1968)
4.80 (0.1890)
1
5
6.20 (0.2441)
5.80 (0.2284)
4
1.27 (0.0500)
BSC
0.25 (0.0098)
0.10 (0.0040)
COPLANARITY
0.10
SEATING
PLANE
1.75 (0.0688)
1.35 (0.0532)
0.51 (0.0201)
0.31 (0.0122)
0.50 (0.0196)
0.25 (0.0099)
45°
8°
0°
0.25 (0.0098)
0.17 (0.0067)
1.27 (0.0500)
0.40 (0.0157)
COMPLIANT TO JEDEC STANDARDS MS-012-A A
CONTROLLING DIMENSIONS ARE IN MILLIMETERS; INCH DIMENSIONS
(IN PARENTHESES) ARE ROUNDED-OFF MILLIMETER EQUIVALENTS FOR
REFERENCE ONLY AND ARE NOT APPROPRIATE FOR USE IN DESIGN.
Figure 27. 8-Lead Standard Small Outline Package [SOIC_N]
Narrow Body
(R-8)
Dimensions shown in millimeters and (inches)
Rev. J | Page 21 of 23
012407-A
8
4.00 (0.1574)
3.80 (0.1497)
AD7416/AD7417/AD7418
Data Sheet
5.10
5.00
4.90
16
9
4.50
4.40
4.30
6.40
BSC
1
8
PIN 1
1.20
MAX
0.15
0.05
0.20
0.09
0.30
0.19
0.65
BSC
SEATING
PLANE
COPLANARITY
0.10
0.75
0.60
0.45
8°
0°
COMPLIANT TO JEDEC STANDARDS MO-153-AB
Figure 28. 16-Lead Thin Shrink Small Outline Package [TSSOP]
(RU-16)
Dimensions shown in millimeters
3.20
3.00
2.80
8
3.20
3.00
2.80
1
5.15
4.90
4.65
5
4
PIN 1
0.65 BSC
0.95
0.85
0.75
1.10 MAX
0.15
0.00
0.38
0.22
COPLANARITY
0.10
0.23
0.08
8°
0°
0.80
0.60
0.40
SEATING
PLANE
COMPLIANT TO JEDEC STANDARDS MO-187-AA
Figure 29. 8-Lead Mini Small Outline Package [MSOP]
(RM-8)
Dimensions shown in millimeters
ORDERING GUIDE
Model 1
AD7416ARZ
AD7416ARZ-REEL
AD7416ARZ-REEL7
AD7416ARM
AD7416ARM-REEL7
AD7416ARMZ
AD7416ARMZ-REEL
AD7416ARMZ-REEL7
Temperature Range
−40°C to +125°C
−40°C to +125°C
−40°C to +125°C
−40°C to +125°C
−40°C to +125°C
−40°C to +125°C
−40°C to +125°C
−40°C to +125°C
Temperature
Error
±2°C
±2°C
±2°C
±2°C
±2°C
±2°C
±2°C
±2°C
Package Description
8-Lead Standard Small Outline Package [SOIC_N]
8-Lead Standard Small Outline Package [SOIC_N]
8-Lead Standard Small Outline Package [SOIC_N]
8-Lead Mini Small Outline Package [MSOP]
8-Lead Mini Small Outline Package [MSOP]
8-Lead Mini Small Outline Package [MSOP]
8-Lead Mini Small Outline Package [MSOP]
8-Lead Mini Small Outline Package [MSOP]
Rev. J | Page 22 of 23
Marking
Code 2
C6A
C6A
C6A#
C6A#
C6A#
Package
Option
R-8
R-8
R-8
RM-8
RM-8
RM-8
RM-8
RM-8
Data Sheet
Model 1
AD7417AR
AD7417AR-REEL
AD7417ARZ
AD7417ARZ-REEL
AD7417ARZ-REEL7
AD7417ARU
AD7417ARU-REEL
AD7417ARU-REEL7
AD7417ARUZ
AD7417ARUZ-REEL
AD7417ARUZ-REEL7
AD7417BR
AD7417BR-REEL7
AD7417BRZ
AD7417BRZ-REEL
AD7417BRZ-REEL7
AD7418ACHIPS
AD7418ARZ
AD7418ARZ-REEL
AD7418ARZ-REEL7
AD7418ARM
AD7418ARMZ
AD7418ARMZ-REEL7
EVAL-AD7416/7/8EBZ
1
2
AD7416/AD7417/AD7418
Temperature Range
−40°C to +125°C
−40°C to +125°C
−40°C to +125°C
−40°C to +125°C
−40°C to +125°C
−40°C to +125°C
−40°C to +125°C
−40°C to +125°C
−40°C to +125°C
−40°C to +125°C
−40°C to +125°C
−40°C to +85°C
−40°C to +85°C
−40°C to +85°C
−40°C to +85°C
−40°C to +85°C
Temperature
Error
±2°C
±2°C
±2°C
±2°C
±2°C
±2°C
±2°C
±2°C
±2°C
±2°C
±2°C
±1°C
±1°C
±1°C
±1°C
±1°C
−40°C to +125°C
−40°C to +125°C
−40°C to +125°C
−40°C to +125°C
−40°C to +125°C
−40°C to +125°C
±2°C
±2°C
±2°C
±2°C
±2°C
±2°C
Package Description
16-Lead Standard Small Outline Package [SOIC_N]
16-Lead Standard Small Outline Package [SOIC_N]
16-Lead Standard Small Outline Package [SOIC_N]
16-Lead Standard Small Outline Package [SOIC_N]
16-Lead Standard Small Outline Package [SOIC_N]
16-Lead Thin Shrink Small Outline Package [TSSOP]
16-Lead Thin Shrink Small Outline Package [TSSOP]
16-Lead Thin Shrink Small Outline Package [TSSOP]
16-Lead Thin Shrink Small Outline Package [TSSOP]
16-Lead Thin Shrink Small Outline Package [TSSOP]
16-Lead Thin Shrink Small Outline Package [TSSOP]
16-Lead Standard Small Outline Package [SOIC_N]
16-Lead Standard Small Outline Package [SOIC_N]
16-Lead Standard Small Outline Package [SOIC_N]
16-Lead Standard Small Outline Package [SOIC_N]
16-Lead Standard Small Outline Package [SOIC_N]
Die
8-Lead Standard Small Outline Package [SOIC_N]
8-Lead Standard Small Outline Package [SOIC_N]
8-Lead Standard Small Outline Package [SOIC_N]
8-Lead Mini Small Outline Package [MSOP]
8-Lead Mini Small Outline Package [MSOP]
8-Lead Mini Small Outline Package [MSOP]
Evaluation Board
Z = RoHS Compliant Part.
# denotes RoHS compliant product may be top or bottom marked.
I2C refers to a communications protocol originally developed by Philips Semiconductors (Now NXP Semiconductors).
©1998–2018 Analog Devices, Inc. All rights reserved. Trademarks and
registered trademarks are the property of their respective owners.
D01126-0-4/18(J)
Rev. J | Page 23 of 23
Marking
Code 2
C7A
T0G
T0G
Package
Option
R-16
R-16
R-16
R-16
R-16
RU-16
RU-16
RU-16
RU-16
RU-16
RU-16
R-16
R-16
R-16
R-16
R-16
R-8
R-8
R-8
RM-8
RM-8
RM-8