0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
AD9524/PCBZ

AD9524/PCBZ

  • 厂商:

    AD(亚德诺)

  • 封装:

    -

  • 描述:

    BOARD EVAL FOR AD9524

  • 数据手册
  • 价格&库存
AD9524/PCBZ 数据手册
Evaluation Board User Guide UG-169 One Technology Way • P.O. Box 9106 • Norwood, MA 02062-9106, U.S.A. • Tel: 781.329.4700 • Fax: 781.461.3113 • www.analog.com Evaluating the AD9523/AD9524 Clock Generator FEATURES GENERAL DESCRIPTION Simple power connection using USB connection and on-board LDO voltage regulators LDOs are easily bypassed for power measurements AC-coupled differential SMA connectors SMA connectors for 2 reference inputs 2 PLL status outputs 1 reference test input 2 VCXO interface inputs/outputs Microsoft Windows®–based evaluation software with simple graphical user interface On-board PLL loop filter Easy access to digital I/O and diagnostic signals via I/O header Status LEDs for diagnostic signals USB computer interface Software calculator provides flexibility, allowing programming of almost any rational input/output frequency ratio This user guide describes the hardware and software of the AD9523 and AD9524 evaluation boards, and includes detailed schematics and PCB layout artwork. The AD9523 and AD9524 are designed to operate in the same manner. This user guide serves both boards but refers to the AD9523. The AD9523 is defined to support the clock requirements for long-term evolution (LTE) and multicarrier GSM base station designs. It relies on an external VCXO to provide the reference jitter cleanup to achieve the restrictive phase noise requirements necessary for acceptable data converter SNR performance. The input receivers, oscillator, and zero delay receiver provide both single-ended and differential operation. When connected to a 30.72 MHz to 122.88 MHz reference clock and a VCXO of either 30.72 MHz to 122.88 MHz, the device generates low noise outputs from a range of 0.96 MHz to 983.04 MHz. 09171-001 DIGITAL PICTURE OF EVALUATION BOARD Figure 1. AD9523 Evaluation Board PLEASE SEE THE LAST PAGE FOR AN IMPORTANT WARNING AND LEGAL TERMS AND CONDITIONS. Rev. 0 | Page 1 of 12 UG-169 Evaluation Board User Guide TABLE OF CONTENTS Features .............................................................................................. 1  Using the Software ........................................................................5  General Description ......................................................................... 1  Software Operation ...........................................................................6  Digital Picture of Evaluation Board ............................................... 1  Menu Bar of Main Window .........................................................7  Revision History ............................................................................... 2  Evaluation Board Hardware ............................................................ 3  Using the Software to Control the Functional Blocks of AD9523...........................................................................................8  Setting Up Jumper Connections................................................. 3  PLL 1 Controls...............................................................................8  Setting Up the Power and PC Connections .............................. 3  PLL 2 Controls...............................................................................9  Setting Up the Signal Connections ............................................ 3  Channel Divider Window ......................................................... 10  Bypassing the 6 V Wall Socket Power Supply........................... 3  Output Driver Window ............................................................. 10  Using I2C Serial Port Mode ......................................................... 4  EEPROM Control ...................................................................... 11  Evaluation Board Software Setup ................................................... 5  Quick Start Guide to the AD9523 ................................................ 12  Installing the Software ................................................................. 5  REVISION HISTORY 7/10—Revision 0: Initial Version Rev. 0 | Page 2 of 12 Evaluation Board User Guide UG-169 EVALUATION BOARD HARDWARE The following instructions are for setting up the physical connections to the AD9523 evaluation board. SETTING UP THE SIGNAL CONNECTIONS After setting up the power and PC connections, use the following procedure to set up the signal connections: SETTING UP JUMPER CONNECTIONS The evaluation board is configured for proper PC control and operation. If the jumpers are inadvertently moved, use Figure 2 and Figure 3 to reconfigure the board. 1. 2. Connect a signal generator to REF A SMA Connector J9. By default, the reference inputs on this evaluation board are ac-coupled and terminated 50 Ω to ground. An amplitude setting of 6 dBm is sufficient. Connect an oscilloscope, spectrum analyzer, or other lab equipment to any of the OUTx SMA connectors on the right side of the board. The output connectors are singleended outputs of a differential pair. A 50 Ω termination should be placed on all unused differential output pair. 09171-002 BYPASSING THE 6 V WALL SOCKET POWER SUPPLY Figure 2. USB and SPI Jumper Connections SETTING UP THE POWER AND PC CONNECTIONS Set up the power and PC connections as follows: 1. 2. 3. 4. Install the AD9523 evaluation software before connecting the evaluation board to the PC for the first time (see the Installing the Software section). Administrative privileges are required for installation. Connect the 6 V wall adapter to Connector P7 of the evaluation board. Connect the USB cables to the evaluation board and the computer. Found New Hardware Wizard automatically appears when the evaluation board is connected. Select Install the software automatically and then click Next. The evaluation board contains a dc-to-dc converter to step down the 6 V to 2.2 V and 4 V. Linear regulators are then used to further regulate the 2.2 V to 1.8 V supply domain and the 4 V to the 3.3 V supply domain. The evaluation board can be configured to bypass the dc-to-dc converter and linear regulators or the dc-to-dc converter only. This is useful for measuring the AD9523 power consumption. Refer to the evaluation board schematics provided on the CD in the evaluation board kit (also available at www.analog.com) for further details. Bypass the 6 V power supply (dc-to-dc converter and linear regulators) as follows: 1. 2. The Found New Hardware Wizard may appear twice, and a system restart may be required. Refer to the Evaluation Board Software Setup section for details on running the AD9523 evaluation board software. Note that it is very important to not have the 6 V supply connected to the evaluation board while using external supplies. To be safe, remove the inductors from each linear regulator output (L4 to L15). Connect a bench power supply to each of the supply pins on Header TP3 through Header TP15. If the inductors were not removed in Step 1, then some of the supply pins are connected together on the evaluation board and damage to the external supply and/or evaluation board may occur. Bypass the 6 V power supply (dc-to-dc converter only) as follows: 1. 2. Rev. 0 | Page 3 of 12 Remove L1, L2, L3, R39, R41, R40, and R42. Connect a 2.2 V bench supply to Connector P19. Connect a 4 V bench supply to the L1 pad. UG-169 Evaluation Board User Guide USING I2C SERIAL PORT MODE 1. 2. 09171-004 3. Figure 3. I2C Address Jumper Setting Rev. 0 | Page 4 of 12 Select the desired I2C address using Jumpers P5 and P6 (see Figure 3). Note that setting P5 and P6 low is reserved for SPI mode. On the evaluation software, select Configure Serial Port from the I/O menu (see the I/O Menu section). Click the Reset Serial Port button, and then click Detect Current Configuration (see Figure 8). A dialog box should appear to acknowledge the I2C mode and address. Evaluation Board User Guide UG-169 EVALUATION BOARD SOFTWARE SETUP The main window of the evaluation board software appears. Proceed to the Software Operation section for more details about using the software. The instructions included in this section are for setting up the AD9523 evaluation board software. INSTALLING THE SOFTWARE 4. Do not connect the evaluation board until the software installation is complete. To install the software, 2. 3. 4. Insert the AD9523 evaluation software CD-ROM into a PC CD disc drive. Click My Computer, and then double-click the AD9523EV CD icon. A window opens showing the contents of the CD divided into four sections: data sheet, layout, schematic, and software. The readme.txt file contains a description of the CDROM contents, as well as any last minute instructions or information. Double-click the Software folder, and then double-click AD9523Eval_Setup1.1.0.exe. Follow the installation instructions. The default location for the evaluation software is C:\Program Files\Analog Devices\AD9523 Eval Software\. If there are any updates to the evaluation software on a supplemental CD or in the \Software\Updates folder, be sure to copy the new .exe file, as well as any setup files, to the default location. 5. 09171-005 1. If the evaluation board was not found, a dialog box appears that allows you to select an evaluation board to use while the software runs in standalone mode. Standalone mode is useful for viewing and generating register setup files. If you connect the evaluation board while the evaluation board software is running, the window shown in Figure 4 usually appears to prompt you to load the evaluation board with the evaluation board software settings or to read the current evaluation board settings into the software. USING THE SOFTWARE After the evaluation software has been installed, you can run the software as follows: 1. 2. Figure 4. SYNC Evaluation Software Window 6. Power up and connect the evaluation board to the PC. Double-click AD9523 Eval Software to run the AD9523 evaluation software. If the evaluation board was not automatically detected when it was connected, choose Select Evaluation Board from the I/O menu, and then select Ezssp-0, Ezssp-1, or Ezssp-2 (see Figure 5). A hardware installation window appears. Depending on whether the evaluation board was found by the software, the text in this window is either light blue, indicating that the evaluation board was found, or red, indicating that the evaluation board was not found. If the evaluation board was found, click in the window when the Evaluation Software Ready message appears. 09171-006 3. Figure 5. Select USB Device Window Rev. 0 | Page 5 of 12 UG-169 Evaluation Board User Guide SOFTWARE OPERATION When a subsection window closes after clicking OK, the WRITE button on the main window may start blinking. This indicates that there are settings that have not been loaded to the AD9523 evaluation board. Click WRITE to load these settings to the evaluation board. 09171-007 The main window of the AD9523 evaluation board software comprises subsections that correspond to the major functional blocks of the AD9523 (see Figure 6). These subsections, most of which have their own window, are outlined in this section. From the main window, the window for each functional block can be accessed by clicking the appropriate box. Figure 6. AD9523 Evaluation Software Main Window Rev. 0 | Page 6 of 12 Evaluation Board User Guide UG-169 MENU BAR OF MAIN WINDOW File Menu The File menu allows you to load a previously saved AD9523 setup file or to save a new AD9523 setup file. A setup file (.stp) is a text file that contains the AD9523 register setup file, plus any evaluation board settings. To load a previously saved setup file, select Load Setup from the File menu. Note that you must still perform a VCO calibration. Alternatively, to save a new setup file, select Save Setup from the File menu. 09171-009 To exit the evaluation software, select Exit from the File menu. However, note that you must save your setup before exiting; no checking is performed to ensure that the existing setup is saved. I/O Menu Figure 8. Serial Port Configuration Window View Menu The Debug window, accessed by selecting Debug Window from the View menu, allows you to write and read registers directly and to force the various configuration pins high or low (see Figure 9). 09171-008 The AD9523 evaluation system allows one PC to control multiple evaluation boards. The Select USB Device window, accessed by choosing Select Evaluation Board from the I/O menu, allows you to select which evaluation board the software controls (see Figure 7). Click Refresh List to detect a recently connected evaluation board. Figure 7. Select USB Device Window The serial port configuration window allows you to control how the USB controller interacts with the AD9523 serial port. If you are using I2C mode, this window allows you to select which address to use. Note that it should correspond to the settings of Jumpers P5 and P6 on the evaluation board. You can also click the Detect Current Configuration button to have the evaluation software discover which I2C address is active. Rev. 0 | Page 7 of 12 09171-010 Selecting Configure Serial Port from the I/O menu allows you to control how the USB controller interacts with the AD9523 serial port (see Figure 8) by configuring Register 0x0000 (shown as 0000h in Figure 10). Figure 9. Debug Window UG-169 Evaluation Board User Guide The Register Map Values window, accessed by selecting Register Map Window from the View menu, allows you to read registers (see Figure 10). Each button has three options: Strobe, Latch, and Release. Strobe activates the pin, and then releases it. Latch holds the pin active until the Release command is issued. PLL 1 CONTROLS 09171-011 09171-012 The PLL 1 box in the main window (see Figure 6) allows you to configure the PLL1 parameters. Clicking the PLL 1 box in Figure 11 opens a window to allow configuration of PLL1 (see Figure 12 ). Figure 10. Register Map Window Help Menu Selecting Help from the Help menu opens the About AD9523 window, which contains information such as revision number, region information, and contact information. Figure 11. PLL1 Box (in Main Window) Clicking each individual box in the PLL 1 Controls window opens a new window to allow configuration of that block (see Figure 13 for an example for the REF A Divider window). USING THE SOFTWARE TO CONTROL THE FUNCTIONAL BLOCKS OF AD9523 Register W/R The Register W/R (write/read) section has three buttons and three check boxes. The WRITE button transfers the values stored in the evaluation software to the evaluation board. It blinks red when register values have changed. The UPDATE button issues an I/O update command by writing to the I/O update register. 09171-013 The READ button transfers the values stored in the evaluation board to the evaluation software. Figure 12. PLL1 Control Box Reference (REF) Divider Window Selecting the All checkbox transfers all of the registers when the WRITE button is clicked. When this box is not selected, only the registers whose value has changed are written. Selecting the Auto checkbox adjacent to the WRITE button forces the evaluation software to write the register changes to the evaluation board automatically when they occur. SYNC, PD (Power Down), and RESET The SYNC, PD, and RESET buttons allow you to control the SYNC, PD, and RESET pins on the AD9523. 09171-014 Selecting the Auto checkbox adjacent to the UPDATE box forces the evaluation software to issue an I/O update command whenever registers are written to the AD9523. Figure 13. Reference A or B Divider Window The REF (Reference) Divider window shown in Figure 13 is accessed by clicking the REF A Divider box in Figure 12. It allows you to set the reference divider. There is a corresponding window for both REF A and REF B dividers. Rev. 0 | Page 8 of 12 Evaluation Board User Guide UG-169 09171-015 Feedback (N) Divider Window Figure 14. N Divider Window 09171-017 The feedback divider window shown in Figure 14 is accessed by clicking the N DIVIDER box in Figure 12. It allows you to set the feedback divider. Charge Pump Window Figure 16. PLL2 Box (in Main Window) 09171-018 09171-016 Clicking each individual box in the PLL 2 Controls window opens a new window to allow configuration of that block. Figure 15. Charge Pump Window Figure 17. PLL 2 Controls Window The Charge Pump Setup window shown in Figure 15 is accessed by clicking the CHARGE PUMP box in Figure 12. Feedback (N) Divider Window This window is most often used to vary the charge pump current. PLL 2 CONTROLS 09171-019 Clicking the PLL 2 box from the main window (see Figure 16) opens a window to allow configuration of PLL2 (see Figure 17). Figure 18. N Divider Window The N Divider window shown in Figure 18 is accessed by clicking the N DIVIDER box in Figure 17. It allows you to set the feedback divider. Rev. 0 | Page 9 of 12 UG-169 Evaluation Board User Guide Charge Pump Window 09171-025 You can also vary the phase offset by changing the phase offset bits setting under the Divider Phase box in Figure 20. However, for the new phase to take effect, the SYNC signal must be toggled, by clicking the SYNC button shown in Figure 22 and selecting Strobe SyncB. Figure 22. Toggling SYNC Signal 09171-020 OUTPUT DRIVER WINDOW Figure 19. Charge Pump Window The Charge Pump Setup window shown in Figure 19 is accessed by clicking the CHARGE PUMP box in Figure 17. This window is most often used to vary the charge pump current. 09171-022 CHANNEL DIVIDER WINDOW Figure 23. Output Driver Window 09171-021 The output driver window shown in Figure 23 is accessed by clicking any of the triangular output driver symbols on the right side of the main window (see Figure 24). Figure 20. Channel Divider Window 09171-026 The channel divider window shown in Figure 20 is accessed by clicking the appropriate channel divider (see Figure 21) in the main window in Figure 6. It is usually sufficient to change only the divide ratio, because the evaluation software and the AD9523 duty cycle correction feature ensure that the output duty cycle remains very close to 50%. Figure 24. Output Drivers 09171-027 It is important to power down unused outputs on the evaluation board, because they can be a major source of unwanted spurs. Figure 21. Channel Divider The outputs are ac-coupled with 100 Ω differential resistors on each output. This termination scheme is ideal for LVPECL drivers. However, this scheme degrades the CMOS driver performance. Improved CMOS driver performance is achieved by removing the 100 Ω resistors. Rev. 0 | Page 10 of 12 Evaluation Board User Guide UG-169 3. 09171-023 EEPROM CONTROL Reconnect the 6 V power supply. This automatically loads the EEPROM settings into the AD9523. The programmed settings can be observed at the outputs. In addition, a window opens (see Figure 26). Click the second option to read from the AD9523. This loads the control software with the current register settings that were programmed by the EEPROM. Figure 25. EEPROM Control Window The EEPROM Control window is shown in Figure 25 is accessed by clicking the EEPROM button near the lower left corner of the main window. To store the current register settings of the AD9523 to the EEPROM, click the Program EEPROM button. Visually confirm the EEPROM Status Registers section on the right side of the window to verify that the operation is successful. 1. 2. Disconnect the 6 V power connector to power down the AD9523. Ensure that the EEPROM pin is pulled high by placing the P4 EEPROM_SEL jumper of the evaluation board across the center and left (high) pin (see Figure 3). 09171-024 To load the values stored in the EEPROM: Figure 26. Software Evaluation Board Software Sync Window Rev. 0 | Page 11 of 12 UG-169 Evaluation Board User Guide QUICK START GUIDE TO THE AD9523 The AD9523 can be initialized at startup from either the EEPROM or from SPI settings. The AD9523 evaluation board ships with initial settings programmed in the EEPROM. It is advised that the user first use the preprogrammed EEPROM settings before proceeding onto software control. To load the provided setup file: 1. 2. To load the values stored in the EEPROM: 1. 2. 3. 4. Ensure that the EEPROM pin is pulled high by placing the P4 EEPROM_SEL jumper of the evaluation board across the center and left (high) pin (see Figure 3). Connect a signal generator to REF A SMA Connector J9. By default, the reference inputs on this evaluation board are ac-coupled and terminated 50 Ω to ground. An amplitude setting of 6 dBm is sufficient and the frequency should be 30.72 MHz. Connect an oscilloscope, spectrum analyzer, or other lab equipment to OUT1 SMA connector on the right side of the board. This output connector is a single-ended output of a differential pair. Connect the 6 V power supply. This automatically loads the EEPROM settings into the AD9523 (the EEPROM configurations are similar as shown in Figure 6). 3. 4. 5. 6. 7. Follow the instructions provided in the Evaluation Board Software Setup section. Ensure that the EEPROM pin is pulled low by placing the P4 EEPROM_SEL jumper of the evaluation board across the center and right (low) pin (see Figure 3). Connect a signal generator to REF A SMA Connector J9. By default, the reference inputs on this evaluation board are ac-coupled and terminated 50 Ω to ground. An amplitude setting of 6 dBm is sufficient and the frequency should be 30.72 MHz. Connect the 6 V power supply. Provided on the CD is a setup file called AD9523_983plan_122p88MHz_VCXO_DoublerON.stp located in the Setup Files directory. Load this setup file using the File menu from the main software window. The main window should appear as shown in Figure 6. Click the CAL VCO button located in the PLL 2 box of Figure 6. Connect an oscilloscope, spectrum analyzer, or other lab equipment to OUT1 SMA connector on the right side of the board. This output connector is a single-ended output of a differential pair. A picture of phase noise profile is located in the same directory as the setup file with the same file name (with .png extension). ESD Caution ESD (electrostatic discharge) sensitive device. Charged devices and circuit boards can discharge without detection. Although this product features patented or proprietary protection circuitry, damage may occur on devices subjected to high energy ESD. Therefore, proper ESD precautions should be taken to avoid performance degradation or loss of functionality. Legal Terms and Conditions By using the evaluation board discussed herein (together with any tools, components documentation or support materials, the “Evaluation Board”), you are agreeing to be bound by the terms and conditions set forth below (“Agreement”) unless you have purchased the Evaluation Board, in which case the Analog Devices Standard Terms and Conditions of Sale shall govern. Do not use the Evaluation Board until you have read and agreed to the Agreement. Your use of the Evaluation Board shall signify your acceptance of the Agreement. This Agreement is made by and between you (“Customer”) and Analog Devices, Inc. (“ADI”), with its principal place of business at One Technology Way, Norwood, MA 02062, USA. Subject to the terms and conditions of the Agreement, ADI hereby grants to Customer a free, limited, personal, temporary, non-exclusive, non-sublicensable, non-transferable license to use the Evaluation Board FOR EVALUATION PURPOSES ONLY. Customer understands and agrees that the Evaluation Board is provided for the sole and exclusive purpose referenced above, and agrees not to use the Evaluation Board for any other purpose. Furthermore, the license granted is expressly made subject to the following additional limitations: Customer shall not (i) rent, lease, display, sell, transfer, assign, sublicense, or distribute the Evaluation Board; and (ii) permit any Third Party to access the Evaluation Board. As used herein, the term “Third Party” includes any entity other than ADI, Customer, their employees, affiliates and in-house consultants. The Evaluation Board is NOT sold to Customer; all rights not expressly granted herein, including ownership of the Evaluation Board, are reserved by ADI. CONFIDENTIALITY. This Agreement and the Evaluation Board shall all be considered the confidential and proprietary information of ADI. Customer may not disclose or transfer any portion of the Evaluation Board to any other party for any reason. Upon discontinuation of use of the Evaluation Board or termination of this Agreement, Customer agrees to promptly return the Evaluation Board to ADI. ADDITIONAL RESTRICTIONS. Customer may not disassemble, decompile or reverse engineer chips on the Evaluation Board. Customer shall inform ADI of any occurred damages or any modifications or alterations it makes to the Evaluation Board, including but not limited to soldering or any other activity that affects the material content of the Evaluation Board. Modifications to the Evaluation Board must comply with applicable law, including but not limited to the RoHS Directive. TERMINATION. ADI may terminate this Agreement at any time upon giving written notice to Customer. Customer agrees to return to ADI the Evaluation Board at that time. LIMITATION OF LIABILITY. THE EVALUATION BOARD PROVIDED HEREUNDER IS PROVIDED “AS IS” AND ADI MAKES NO WARRANTIES OR REPRESENTATIONS OF ANY KIND WITH RESPECT TO IT. ADI SPECIFICALLY DISCLAIMS ANY REPRESENTATIONS, ENDORSEMENTS, GUARANTEES, OR WARRANTIES, EXPRESS OR IMPLIED, RELATED TO THE EVALUATION BOARD INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTY OF MERCHANTABILITY, TITLE, FITNESS FOR A PARTICULAR PURPOSE OR NONINFRINGEMENT OF INTELLECTUAL PROPERTY RIGHTS. IN NO EVENT WILL ADI AND ITS LICENSORS BE LIABLE FOR ANY INCIDENTAL, SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES RESULTING FROM CUSTOMER’S POSSESSION OR USE OF THE EVALUATION BOARD, INCLUDING BUT NOT LIMITED TO LOST PROFITS, DELAY COSTS, LABOR COSTS OR LOSS OF GOODWILL. ADI’S TOTAL LIABILITY FROM ANY AND ALL CAUSES SHALL BE LIMITED TO THE AMOUNT OF ONE HUNDRED US DOLLARS ($100.00). EXPORT. Customer agrees that it will not directly or indirectly export the Evaluation Board to another country, and that it will comply with all applicable United States federal laws and regulations relating to exports. GOVERNING LAW. This Agreement shall be governed by and construed in accordance with the substantive laws of the Commonwealth of Massachusetts (excluding conflict of law rules). Any legal action regarding this Agreement will be heard in the state or federal courts having jurisdiction in Suffolk County, Massachusetts, and Customer hereby submits to the personal jurisdiction and venue of such courts. The United Nations Convention on Contracts for the International Sale of Goods shall not apply to this Agreement and is expressly disclaimed. ©2010 Analog Devices, Inc. All rights reserved. Trademarks and registered trademarks are the property of their respective owners. UG09171-0-7/10(0) Rev. 0 | Page 12 of 12
AD9524/PCBZ 价格&库存

很抱歉,暂时无法提供与“AD9524/PCBZ”相匹配的价格&库存,您可以联系我们找货

免费人工找货