0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
AD9552/PCBZ

AD9552/PCBZ

  • 厂商:

    AD(亚德诺)

  • 封装:

    -

  • 描述:

    BOARD EVALUATION FOR AD9552

  • 数据手册
  • 价格&库存
AD9552/PCBZ 数据手册
Evaluation Board User Guide UG-035 One Technology Way • P.O. Box 9106 • Norwood, MA 02062-9106, U.S.A. • Tel: 781.329.4700 • Fax: 781.461.3113 • www.analog.com Evaluating the AD9552 Oscillator Frequency Upconverter FEATURES GENERAL DESCRIPTION Simple power connection using USB connection and on-board LDO voltage regulators LDOs are easily bypassed for power measurements AC-coupled differential LVPECL SMA connectors SMA connectors for 1 reference input 1 PLL lock detect output Microsoft Windows®–based evaluation software with simple graphical user interface On-board PLL loop filter Easy access to digital I/O and diagnostic signals via I/O header Status LEDs for diagnostic signals USB computer interface Dip switch configurable for manual operation Software calculator provides flexibility, allowing programming almost any rational input/output frequency ratio This user guide describes the hardware and software of the AD9552 evaluation board and includes detailed schematics and PCB layout artwork. The AD9552 evaluation board is a compact, easy to use platform for evaluating all features of the AD9552 oscillator frequency upconverter. The AD9552 is a fractional-N phase-locked loop (PLL) based clock generator designed specifically to replace high frequency crystal oscillators and resonators. The device employs a sigmadelta (Σ-Δ) modulator (SDM) to accommodate fractional frequency synthesis. The user supplies an input reference signal by connecting a single-ended clock signal directly to the REF pin or by connecting a crystal resonator across the XTAL pins. The AD9552 is pin programmable, providing one of 64 standard output frequencies based on one of eight standard input frequencies. The device also has a 3-wire SPI interface, enabling the user to program custom input-to-output frequency ratios. The AD9552 relies on an external capacitor to complete the loop filter of the PLL. The output is compatible with LVPECL, LVDS, or single-ended CMOS logic levels, although the AD9552 is implemented in a strictly CMOS process. 08390-001 DIGITAL PICTURE OF THE EVALUATION BOARD Figure 1. AD9552 Evaluation Board See the last page for an important warning and disclaimers. Rev. 0 | Page 1 of 12 UG-035 Evaluation Board User Guide TABLE OF CONTENTS Features .............................................................................................. 1  Using an SPI Port ..........................................................................5  General Description ......................................................................... 1  Using Dip Switches (Manual Control) .......................................5  Digital Picture of the Evaluation Board ......................................... 1  Using Software to Override Dip Switches (Software Control)5  Revision History ............................................................................... 2  Software Operation ...........................................................................6  Evaluation Board Hardware ............................................................ 3  Menu Bar of Main Window .........................................................7  Setting Up the Power and PC Connections .............................. 3  Button Bar of Main Window .......................................................8  Setting Up the Signal Connections ............................................ 3  Bypassing the USB Power Supply ............................................... 3  Using Software to Control the Functional Blocks of the AD9552 ...........................................................................................8  Evaluation Board Software .............................................................. 4  Using Software to Calculate the Device Settings ................... 10  Installing the Software ................................................................. 4  Routing 26 MHz to Test Port .................................................... 10  Using the Software........................................................................ 4  ESD Caution................................................................................ 12  Guide to Programming the AD9552.............................................. 5  REVISION HISTORY 1/10—Revision 0: Initial Version Rev. 0 | Page 2 of 12 Evaluation Board User Guide UG-035 EVALUATION BOARD HARDWARE 3. The following instructions are for setting up the physical connections to the AD9552 evaluation board. SETTING UP THE POWER AND PC CONNECTIONS The Found New Hardware Wizard may appear twice, and a system restart may be required. Set up the power and PC connections as follows: 1. Install the AD9552 evaluation software before connecting the evaluation board to your PC for the first time (see the Installing the Software section). Administrative privileges are required for installation. The AD9552 has the option of either being pin or register programmable. If the pin-programmable option is desired, then no software is needed to control the part. However, it is recommended to install the software because if it is not installed, the computer recognizes the evaluation board as new hardware and attempts to install drivers. 2. Connect the USB cables to the evaluation board and the computer. If the Found New Hardware Wizard automatically appears when the evaluation board is connected, select Install the software automatically and then click Next. Refer to the Evaluation Board Software section for details on running the AD9552 evaluation board software. SETTING UP THE SIGNAL CONNECTIONS After setting up the power and PC connections, use the following procedure to set up the signal connections: 1. Connect an oscilloscope, spectrum analyzer, or other lab equipment to any of the J3 to J6 SMA connectors on the upper right side of the board. The output connectors are single ended. A 50 Ω termination should be placed on all enabled unused outputs. BYPASSING THE USB POWER SUPPLY The red LED labeled VBUS (CR5) on the AD9552 evaluation board should illuminate, and the USB STATUS LED should start blinking. If the USB STATUS LED is not blinking, ensure that the USB port on the PC is operational and that the USB cable is not damaged. The evaluation board can be configured to supply power to the AD9552 from an external power supply. Bypass the USB power supply as follows: 1. Remove the F2 ferrite bead (located on the backside of the board). 2. Connect a bench power supply to Pin 3.3V_1 INPUT of TB1 on the evaluation board. In addition, resistors on the evaluation board can be removed to further separate power supply connections to the AD9552. This is useful for measuring the AD9552 power consumption. Refer to the evaluation board schematics provided on the CD in the evaluation board kit (also available at www.analog.com) for further details. Rev. 0 | Page 3 of 12 UG-035 Evaluation Board User Guide EVALUATION BOARD SOFTWARE A hardware installation window appears. Depending on whether the evaluation board is found by the software, the text in this window is either light blue, indicating that the evaluation board is found, or red, indicating that the evaluation board cannot be found. The instructions included in this section are for setting up the AD9552 evaluation board software. INSTALLING THE SOFTWARE Do not connect the evaluation board until the software installation is complete. To install the software, 1. Insert the AD9552 evaluation software CD-ROM into a PC CD disc drive. 2. Click My Computer, and then double-click the AD9552EV CD icon. A window opens showing the contents of the CD divided into four sections: data sheet, layout, schematic, and software. The readme.txt file contains a description of the CDROM contents, as well as any last minute instructions or information. 3. Double-click the Software folder, and then double-click AD9552Eval_Setup1.1.0.exe. Follow the installation instructions. The default location for the evaluation software is C:\Program Files\Analog Devices\AD9552 Eval Software\. 4. If there are any updates to the evaluation software on a supplemental CD or in the \Software\Updates folder, be sure to copy the new .exe file, as well as any setup files, to the default location. 3. If the evaluation board is found, click in the window when the Evaluation Software Ready message appears. The main window of the evaluation board software appears. Proceed to the Guide to Programming the AD9552 section for more details about using the software. 4. If the evaluation board is not found, a dialog box appears that allows you to select an evaluation board to use while the software runs in standalone mode. Standalone mode is useful for viewing and generating register setup files. 5. If the evaluation board is not automatically detected when it is connected, choose Select Evaluation Board from the I/O menu, and then select Ezssp-0, Ezssp-1, or Ezssp-2 (see Figure 2). 08390-003 USING THE SOFTWARE After the evaluation software has been installed, you can run the software as follows: Figure 2. Select USB Device Window 1. Power up and connect the evaluation board to the PC. 2. Double-click AD9552 Eval Software to run the AD9552 evaluation software. Rev. 0 | Page 4 of 12 Evaluation Board User Guide UG-035 GUIDE TO PROGRAMMING THE AD9552 The AD9552 can be programmed via an SPI port or by setting the logic levels on the frequency select pins of the device. To program the device using the serial port, the evaluation board software must be installed. 5. Connect an oscilloscope, spectrum analyzer, or other lab equipment to any of the J3 to J6 SMA connectors on the upper right side of the board. 6. Power the evaluation board by plugging it into the USB port. For pin programming, there are two options: manually use the dip switches or use the evaluation board software to override the settings of the dip switches and change the logic levels of the frequency select pins. Using the dip switches on the evaluation board to establish the logic levels on the pins allows the AD9552 to power on with preset conditions. Alternatively, you can use the software to override the settings of the dip switches on the evaluation board and change the logic levels on the frequency select pins. 7. A frequency of 622.08 MHz should be observed on the OUT1 SMA connector. After each dip switch setting, the AD9552 must be powered down by removing the USB cable to reprogram the AD9552. See the AD9552 data sheet for an explanation of pin programming. USING SOFTWARE TO OVERRIDE DIP SWITCHES (SOFTWARE CONTROL) USING AN SPI PORT After the evaluation software is installed and the evaluation board is connected to a PC and loaded with the software, the following procedure is used to configure and lock the PLLs. The evaluation board software can be used to override the settings of the dip switches and apply a logic level to the AD9552 frequency selection pins. In this example, the crystal frequency is 26 MHz, and the output frequency is 622.08 MHz. 1. 2. 3. If another output frequency is desired, remove the USB port. Then change the dip switch settings, and reapply the USB port connection. Ensure that Jumper JMP3 is positioned for PC control. Verify that all five jumpers are in place on Connector P2. Set the S1, S2, and S3 switches high. Set the S4 switch setting to high, except for RESET, which must be set to low (RESET is an active high pin). These steps assume that the input signal is present, that the evaluation board has not been modified, and that the PLL loop filter is suitable for the application. However, this guide covers only simple PLL operation (that is, to start and run the PLL). For a detailed explanation of more advanced AD9552 features, see the AD9552 data sheet. In addition, see the Software Operation section. USING DIP SWITCHES (MANUAL CONTROL) The following procedure explains how the AD9552 can be programmed manually by using the dip switches on the evaluation board to set the logic levels of the frequency select pins. In this example, the crystal frequency is 26 MHz, and the output frequency is 622.08 MHz. 1. Ensure that Jumper JMP3 is positioned for manual control. 2. Verify that all five jumpers are removed on Connector P2. 3. Set the positions of the S3 dip switches to high to indicate a 26 MHz crystal is being used. 4. Set the positions of the S2 Y5 and Y4 dip switches to high and the positions of the S1 Y3 and Y0 dip switches to 0100. After the evaluation software is installed and the evaluation board is connected to a PC and loaded with the software, the following steps are used to configure and lock the PLLs. In this example, the crystal frequency is 26 MHz, and the output frequency is 622.08 MHz. 1. Ensure that Jumper JMP3 is positioned for PC control. 2. Verify that all five jumpers are in place on Connector P2. 3. Set the S1, S2, and S3 dip switch positions to high. 4. Select 26 MHz for the input frequency in the XTAL Input: box in the main window of the evaluation software (see Figure 3 and the Reference Input Boxes section for more information). 5. Select 622.08 MHz for the output frequency in the Output Loop Config: box in the main window of the evaluation software (see Figure 3). 6. A frequency of 622.08 MHz should be observed on the OUT SMA connector. These steps assume that the input signal is present, that the evaluation board has not been modified, and that the PLL loop filter is suitable for the application. However, these steps are appropriate only for simple PLL operation (that is, to set up and run the PLL). See the AD9552 data sheet for more information about the various AD9552 features. Rev. 0 | Page 5 of 12 UG-035 Evaluation Board User Guide SOFTWARE OPERATION When a subsection window closes after clicking OK, you may notice that the LOAD button on the main window starts blinking. This indicates that there are settings that have not been loaded to the AD9552 evaluation board. Click LOAD to load these settings to the evaluation board. 08390-100 The main window of the AD9552 evaluation board software is comprised of subsections that correspond to the major functional blocks of the AD9552 (see Figure 3). These subsections, most of which have their own window, are outlined in this section. From the main window, the window for each functional block can be accessed by clicking the appropriate box in the main window. Figure 3. AD9552 Evaluation Software Main Window Rev. 0 | Page 6 of 12 Evaluation Board User Guide UG-035 MENU BAR OF MAIN WINDOW File Menu The File menu allows you to load a previously saved AD9552 setup file or to save a new AD9552 setup file. A setup file (.stp) is a text file that contains the AD9552 register setup file, plus any evaluation board settings. To load a previously saved setup file, select Load Setup from the File menu. Note that you must still perform a VCO calibration. Alternatively, to save a new setup file, select Save Setup from the File menu. To exit the evaluation software, select Exit from the File menu. However, note that no checking is done to ensure that the existing setup is saved. Figure 6. Debug Window The Register Map Debug window, accessed by selecting Register Debug Window from the View menu, allows you to write and read registers (see Figure 7). 08390-005 The AD9552 evaluation system allows one PC to control multiple evaluation boards. The Select USB Device window, accessed by choosing Select Evaluation Board from the I/O menu, allows you to select which evaluation board the software controls (see Figure 4). Click Refresh List to detect a recently connected evaluation board. 08390-007 I/O Menu Figure 4. Select USB Device Window 08390-008 Selecting Configure Serial Port from the I/O menu allows you to control how the USB controller interacts with the AD9552 serial port (see Figure 5) by configuring Register 0x00 (shown as 00H in Figure 7). 08390-006 Figure 7. Register Map Debug Window Figure 5. Serial Port Configuration Window View Menu The Debug window, accessed by selecting Debug Window from the View menu, allows you to write and read registers directly and to force the various configuration pins high or low (see Figure 6). Rev. 0 | Page 7 of 12 UG-035 Evaluation Board User Guide Help Menu port writes when conditions are changed in the corresponding subsection window. Selecting Help from the Help menu opens the About AD9551_AD9552 Evaluation Software window, which contains information such as revision number, region information, and contact information. When a subsection window closes after clicking OK, you may notice that the LOAD button on the main window starts blinking. This indicates that there are settings that have not been loaded to the AD9552 evaluation board. Click LOAD to load these settings to the evaluation board. Reference Input Boxes The reference input boxes, which are labeled Reference Input: and XTAL Input: in the main window, allow you to select an input frequency for the external reference input (J1 to REF) or the XTAL frequency. Crystal Control Clicking Click for Details in the Xtal Control box of the main window accesses the Xtal window (see Figure 9 for an example of the crystal control window). 08390-106 If a crystal frequency is chosen that is less than 16 MHz, the doubler is automatically enabled and controlled internally from the AD9552. Figure 8. AD9552 Evaluation Software Window BUTTON BAR OF MAIN WINDOW The buttons described in this section provide easy access to common features. Load and Save Update 08390-101 Clicking Load and Save allows you to load and save an AD9552 setup file. A setup file (.stp) is a text file that contains the AD9552 register setup file, plus any evaluation board settings. Figure 9. Crystal Control Window Clicking Update toggles the I/O update bit (Register 0x05, Bit 0) of the AD9552. Reset Clicking Reset resets the evaluation board and restores the AD9552 to its default power-up state. In addition, clicking Reset enables the VCO calibration function by writing the enable VCO calibration bit. USING SOFTWARE TO CONTROL THE FUNCTIONAL BLOCKS OF THE AD9552 The AD9552 evaluation software contains subsections that correspond to the major functional blocks of the AD9552. These subsections, most of which have their own window, are described in this section. You can access each window by clicking Click for Details in the appropriate subsection box of the main window. Most subsection boxes in the main window have a check box labeled SPI. If this box is selected, the software allows serial Rev. 0 | Page 8 of 12 Evaluation Board User Guide UG-035 PFD and Charge Pump Window 08390-015 08390-102 Clicking Click for Details in the PFD & Charge Pump box of the main window accesses the PFD and Charge Pump window (see Figure 10). Figure 10. PFD and Charge Pump Window VCO Control Window P0, P1, and P2 (Output Dividers) Boxes Selecting the SPI check box in any of the divider settings boxes (that is, the P0, P1, or P2 box) in the main window enables a drop-down selection of predetermined divider settings (see Figure 13). 08390-018 Clicking Click for Details in the VCO box of the main window accesses the VCO Control window (see Figure 11). Figure 12. Feedback Window Figure 13. P0, P1, and P2 Boxes (in Main Window) Output Loop Config: Box 08390-016 The Output Loop Config: box can be used to change the output frequency of the AD9552. This control changes the logic levels of the output frequency selection pins of the AD9552 (see Figure 14). 08390-029 Figure 11. VCO Control Window Feedback Window Clicking Click for Details in the Feedback Divider box of the main window accesses the Feedback window, which allows you to change the feedback divider settings (see Figure 12). Figure 14. Output Loop Config: Box (in Main Window) OutSel Pin: Box 08390-019 The OutSel Pin: drop-down box (see Figure 15) in the main window controls the logic level on the OUTSEL pin of the AD9552. However, this value can be overwritten by using the SPI control register. Figure 15. OutSel Pin Box (in Main Window) Rev. 0 | Page 9 of 12 UG-035 Evaluation Board User Guide USING SOFTWARE TO CALCULATE THE DEVICE SETTINGS 8. Type 26 into the Ref Frequency: box and 122.88 into the Output 1 Base Frequency: box. The following procedure explains how the evaluation board software can be used to automatically calculate and set the settings to program the AD9552. 9. Click Calculate Settings. Because the AD9552 is designed for flexibility, there is more than one possible divider settings to achieve the same output frequency. Click Select From List, located at the top of the Output Settings box (see Figure 18). This generates all possible solutions. The user should click each solution and try to determine which has lowest spur for example. In this example, the crystal frequency is 26 MHz, and the output frequency is 122.88 MHz. Ensure that Jumper JMP3 is positioned for PC control. 2. Verify that all five jumpers are in place on Connector P2. 3. Set the positions of the S1, S2, and S3 dip switches to high. 4. Click Calculate Device Settings in the main window of the evaluation board software. 08390-020 08390-104 1. Figure 19. Calculator Window List Figure 16. Calculate Device Settings Button (in Main Window) 5. 10. Click Apply Settings. You should now be able to measure 122.88 MHz at the OUT1 SMA connector. The Enable Control? window, shown in Figure 17, appears. ROUTING 26 MHz TO TEST PORT The following procedure explains how to route the 26 MHz crystal oscillator to the AD9552 test port. The test port is SMA J7 and is labeled output PLL locked. 08390-021 In this example, the crystal frequency is 26 MHz, and the output frequency is 122.88 MHz. 1. Ensure that Jumper JMP3 is positioned for PC control. 2. Verify that all five jumpers are in place on Connector P2. 3. Set the positions of the S1, S2, and S3 dip switches to high. 4. Click Calculate Device Settings in the main window of the evaluation board software. Figure 17. AD9552 Serial Port Programming Warning Click Yes to enable serial port register programming. 7. The Calculator window, shown in Figure 18, appears. 08390-023 6. Figure 20. Calculate Device Settings Button (in Main Window) 08390-103 5. Figure 18. Calculator Window Rev. 0 | Page 10 of 12 The Enable Control? window, shown in Figure 21, appears. Evaluation Board User Guide UG-035 9. Click Calculate Settings, and then click Apply Settings. You should now be able to measure 122.88 MHz at the OUT1 SMA connector. 08390-024 10. From the View menu in the main window, select Register Debug Window. The window shown in Figure 23 appears. Figure 21. AD9552 Serial Port Programming Warning Click Yes to enable serial port register programming. 7. The Calculator window, shown in Figure 22, appears. 08390-026 6. 08390-105 Figure 23. Register Debug Window Figure 22. Calculator Window 8. Type 26 into the Ref Frequency: box and 122.88 into the Output 1 Base Frequency: box. 11. Bit 3 of Register 0x17 must be set to 1 to enable the PLL locked pin as a test port. By default, the 26 MHz crystal frequency is present at the output. 12. The ac signal has a dc offset of approximately 1.6 V. Be aware that some test equipment has a limit of 0 V dc; therefore, a dc block must be used in such cases. Rev. 0 | Page 11 of 12 UG-035 Evaluation Board User Guide NOTES ESD CAUTION Evaluation boards are only intended for device evaluation and not for production purposes. Evaluation boards are supplied “as is” and without warranties of any kind, express, implied, or statutory including, but not limited to, any implied warranty of merchantability or fitness for a particular purpose. No license is granted by implication or otherwise under any patents or other intellectual property by application or use of evaluation boards. Information furnished by Analog Devices is believed to be accurate and reliable. However, no responsibility is assumed by Analog Devices for its use, nor for any infringements of patents or other rights of third parties that may result from its use. Analog Devices reserves the right to change devices or specifications at any time without notice. Trademarks and registered trademarks are the property of their respective owners. Evaluation boards are not authorized to be used in life support devices or systems. ©2010 Analog Devices, Inc. All rights reserved. Trademarks and registered trademarks are the property of their respective owners. UG08390-0-1/10(0) Rev. 0 | Page 12 of 12
AD9552/PCBZ 价格&库存

很抱歉,暂时无法提供与“AD9552/PCBZ”相匹配的价格&库存,您可以联系我们找货

免费人工找货