0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
DS1344E-3+

DS1344E-3+

  • 厂商:

    AD(亚德诺)

  • 封装:

    TSSOP-20

  • 描述:

    实时时钟 (RTC) IC 时钟/日历 96B SPI 20-TSSOP(0.173",4.40mm 宽)

  • 数据手册
  • 价格&库存
DS1344E-3+ 数据手册
DS1343/DS1344 Low-Current SPI/3-Wire RTCs General Description The DS1343/DS1344 low-current real-time clocks (RTCs) are timekeeping devices that provide an extremely low standby current, permitting longer life from a backup supply source. The devices also support high-ESR crystals, broadening the pool of usable crystals for the devices. The clock/calendar provides seconds, minutes, hours, day, date, month, and year information. The date at the end of the month is automatically adjusted for months with fewer than 31 days, including corrections for leap year. The clock operates in either 24-hour or 12-hour format with an AM/PM indicator. Address and data are transferred serially through an SPI or 3-wire interface. Two programmable time-of-day alarms are provided. Each alarm can generate an interrupt on a combination of seconds, minutes, hours, and day. Don’t-care states can be inserted into one or more fields if it is desired for them to be ignored for the alarm condition. The time-of-day alarms can be programmed to assert two different interrupt outputs, or they can be combined to assert one common interrupt output. Both interrupt outputs operate when the device is powered by either VCC or VBAT. The devices are available in a lead-free/RoHS-compliant, 20-pin TSSOP or 14-pin TDFN package, and support a -40°C to +85°C extended industrial temperature range. Applications Medical Features S Low Timekeeping Current of 250nA (typ) S Compatible with Crystal ESR Up to 100kI S Versions Available to Support Either 6pF or 12.5pF Crystals S RTC Counts Seconds, Minutes, Hours, Day, Date, Month, and Year with Leap Year Compensation Valid Through 2099 S Power-Fail and Switch Circuitry S Three Operating Voltages 1.8V ±5% 3.0V±10% 3.3V ±10% S Trickle-Charge Capability S Maintain Time Down to 1.15V (typ) S Support Motorola SPI Modes 1 and 3, or Standard 3-Wire Interface S Burst Mode for Reading/Writing Successive Addresses in Clock/RAM S 96-Byte Battery-Backed NV RAM for Data Storage S Two Time-of-Day Alarms with Two Interrupt Outputs S Industrial Temperature Range S 20-Pin TSSOP or 14-Pin TDFN Package S Underwriters Laboratories (UL) Recognized Handheld Devices Typical Operating Circuit Telematics Embedded Timestamping VCC RPU INT RST μP Ordering Information appears at end of data sheet. 3-WIRE PORT VCC INT0 PF INT1 CE SCLK SDI SDO X1 DS1343 DS1344 X2 VBAT SERMODE GND NOTE: SHOWN IN 3-WIRE I/O CONFIGURATION. For pricing, delivery, and ordering information, please contact Maxim Direct at 1-888-629-4642, or visit Maxim Integrated’s website at www.maximintegrated.com. 19-5801; Rev 2; 10/14 DS1343/DS1344 Low-Current SPI/3-Wire RTCs ABSOLUTE MAXIMUM RATINGS Voltage Range on VCC or VBAT Relative to Ground.............................................-0.3V to +6.0V Voltage Range on Any Nonpower Pin Relative to Ground................................. -0.3V to (VCC + 0.3V) Operating Temperature Range........................... -40NC to +85NC Junction Temperature Maximum......................................+150NC Storage Temperature Range............................. -55NC to +125NC Lead Temperature (soldering, 10s).................................+260NC Soldering Temperature (reflow).......................................+260NC Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to absolute maximum rating conditions for extended periods may affect device reliability. PACKAGE THERMAL CHARACTERISTICS (Note 1) TSSOP Junction-to-Ambient Thermal Resistance (BJA)...........91NC/W Junction-to-Case Thermal Resistance (BJC)................20NC/W TDFN Junction-to-Ambient Thermal Resistance (BJA)...........54NC/W Junction-to-Case Thermal Resistance (BJC)..................8NC/W Note 1: Package thermal resistances were obtained using the method described in JEDEC specification JESD51-7, using a four-layer board. For detailed information on package thermal considerations, refer to www.maximintegrated.com/thermal-tutorial. RECOMMENDED OPERATING CONDITIONS (TA = -40°C to +85°C, unless otherwise noted.) (Note 2) PARAMETER Operating Voltage Range Minimum Timekeeping Voltage Backup Voltage SYMBOL VCC VBATTMIN CONDITIONS MIN TYP MAX DS134_-18 1.71 1.8 5.5 DS134_-3 2.7 3.0 5.5 DS134_-33 3.0 3.3 5.5 1.15 1.3 V TA = +25NC UNITS V VBAT 1.3 5.5 V Logic 1 Input VIH 0.7 x VCC VCC + 0.3 V Logic 0 Input VIL -0.3 0.3 x VCC V MAX UNITS -3 or -33: fSCLK = 4MHz (Note 4) 400 FA VCC = 3.63V 120 VCC = VCC(MAX) 160 VCC = 3.3V 130 VCC = VCC(MAX) 175 VCC = 1.89V 120 DC ELECTRICAL CHARACTERISTICS (VCC = VCC(MIN) to +5.5V, VBAT = +1.3V to +5.5V, TA = -40°C to +85°C, unless otherwise noted.) (Notes 2, 3) PARAMETER Power-Supply Active Current SYMBOL ICCA CONDITIONS -33 Power-Supply Standby Current (Note 5) ICCS -3 -18 Backup Leakage Current Backup Current (Oscillator Off) Backup Current (Note 6) 2   IBATLKG IBAT DS1343 IBAT1 DS1344 MIN TYP VCC = VCC(MAX) VCC > VPF TA = +25NC, VCC = 0V, EOSC = 1 VBAT = 3V 200 -100 +25 VBAT = VBAT(MAX) +100 nA 100 nA 250 VBAT = VBAT(MAX) VBAT = 3V FA 500 350 nA 600 Maxim Integrated DS1343/DS1344 Low-Current SPI/3-Wire RTCs DC ELECTRICAL CHARACTERISTICS (continued) (VCC = VCC(MIN) to +5.5V, VBAT = +1.3V to +5.5V, TA = -40°C to +85°C, unless otherwise noted.) (Notes 2, 3) PARAMETER Backup Current (Note 7) SYMBOL CONDITIONS MIN VBAT = 3V DS1343 IBAT2 DS1344 TYP MAX UNITS 300 VBAT = VBAT(MAX) 600 VBAT = 3V 400 VBAT = VBAT(MAX) nA 700 Input Leakage (CE, SERMODE, SCLK, SDI) II VIN = 0V to VCC -0.1 +0.1 FA Output Leakage (INT0, INT1, PF, SDO) IO CE = VIL, no alarms -0.1 +0.1 FA Output Logic 1 (PF, SDO) IOH Output Logic 0 (INT0, INT1, PF, SDO) IOL Power-Fail Trip Point VPF Switchover Voltage Trickle-Charger Resistors VSW -3 or -33: VOH = 2.4V -1 mA -18: VOH = 1V -0.5 -3 or -33: VOL = 0.4V 3.0 -18: VOL = 0.4V 2.0 VBAT R 1.3V R VCC + 0.2V, VOL = 0.2V (Note 8) 0.25 -18 1.51 1.6 1.71 -3 2.45 2.6 2.70 -33 2.70 2.88 3.0 mA VBAT > VPF VPF VBAT < VPF VBAT > VCC R1 1 R2 2 R3 4 V V kI AC ELECTRICAL CHARACTERISTICS (VCC = VCC(MIN) to VCC(MAX), TA = -40°C to +85°C, unless otherwise noted.) (Notes 2, 3) PARAMETER SCLK Frequency SYMBOL fSCLK CONDITIONS MIN 1 -3 or -33 DC 4 tDC 30 SCLK to Data Hold tCDH 30 tCDD SCLK Low Time tCL SCLK High Time tCH Maxim Integrated MAX DC Data to SCLK Setup SCLK to Data Delay TYP -18 ns 240 -3 or -33 80 -18 400 110 -18 400 -3 or -33 110 MHz ns -18 -3 or -33 UNITS ns ns ns   3 DS1343/DS1344 Low-Current SPI/3-Wire RTCs AC ELECTRICAL CHARACTERISTICS (continued) (VCC = VCC(MIN) to VCC(MAX), TA = -40°C to +85°C, unless otherwise noted.) (Notes 2, 3) SCLK Rise and Fall tR, tF CE to SCLK Setup tCC 400 ns SCLK to CE Hold tCCH 100 ns CE Inactive Time tCWH CE to Output High-Z tCDZ Oscillator Stop Flag (OSF) Delay tOSF 200 -18 500 -3 or -33 400 (Note 9) ns ns 80 ns 25 100 ms TYP MAX UNITS 20 40 ms POWER-UP/DOWN CHARACTERISTICS (TA = -40°C to +85°C, unless otherwise noted.) PARAMETER SYMBOL Recovery at Power-Up CONDITIONS MIN tREC VCC Fall Time (VPF to 0V) tVCCF 150 Fs VCC Rise Time (0V to VPF) tVCCR 0 Fs CAPACITANCE (TA = +25°C, unless otherwise noted.) PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS Input Capacitance CI (Note 10) 10 pF Output Capacitance CO (Note 10) 15 pF CRYSTAL PARAMETERS PARAMETER Nominal Frequency SYMBOL Series Resistance ESR Load Capacitance CL Note Note Note Note Note Note Note Note Note 4   CONDITIONS fO MIN TYP MAX 32.768 kHz 100 DS1343 6 DS1344 12.5 UNITS kI pF 2: Voltage referenced to ground. 3: Limits at TA = -40°C are guaranteed by design and not production tested. 4: CE = VCC, VSCLK = VCC to GND, IOUT = 0mA, trickle charger disabled. 5: CE = GND, IOUT = 0mA, EOSC = EGFIL = DOSF = 0, trickle charger disabled. 6: VCC = 0V, EGFIL = 0, DOSF = 1. 7: VCC = 0V, EGFIL = 1, DOSF = 0. 8: Applies to INT0 and INT1. 9: The parameter tOSF is the period of time the oscillator must be stopped for the OSF flag to be set. 10: Guaranteed by design; not 100% production tested. Maxim Integrated DS1343/DS1344 Low-Current SPI/3-Wire RTCs SPI Write Timing tCWH CE tCCH tF tCC tCL tCH tR SCLK* tDC SDI tCDH tCDH A6 R/W = 1 A0 D7 WRITE ADDRESS BYTE D0 WRITE DATA BYTE *SCLK CAN BE EITHER POLARITY. TIMING SHOWN FOR CPOL = 1. SERMODE = VCC. SPI Read Timing tCWH CE tCC tCL tCH SCLK* tCDH tCDD tDC SDI R/W = 0 A6 SDO tCDZ A0 D7 WRITE ADDRESS BYTE D0 READ DATA BYTE *SCLK CAN BE EITHER POLARITY. TIMING SHOWN FOR CPOL = 1. SERMODE = VCC. Maxim Integrated   5 DS1343/DS1344 Low-Current SPI/3-Wire RTCs 3-Wire Write Timing tCWH CE tCCH tCC tR tCL tF SCLK tCH tCDH tDC A0 I/O* A1 R/W = 1 D0 WRITE ADDRESS BYTE D7 WRITE DATA BYTE *I/O IS SDI AND SDO CONNECTED TOGETHER. SERMODE = GND. 3-Wire Read Timing tCWH CE tCC tCL tCDZ tCDD SCLK I/O* tCH tCDH tDC A0 A1 WRITE ADDRESS BYTE R/W = 0 D0 D7 READ DATA BYTE *I/O IS SDI AND SDO CONNECTED TOGETHER. SERMODE = GND. 6   Maxim Integrated DS1343/DS1344 Low-Current SPI/3-Wire RTCs Typical Operating Characteristics (VCC = +3.3V, TA = +25°C, unless otherwise noted.) fSCLK = 4MHz 300 200 fSCLK = 1MHz 100 4.0 4.5 5.0 320 TA = +85°C TA = +25°C TA = -40°C 300 EGFIL = 1 DOSF = 0 IOUT = 0mA TA = +85°C 280 260 5.5 TA = +25°C 240 TA = -40°C 220 200 180 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 BATTERY VOLTAGE (V) BATTERY VOLTAGE (V) DS1344 BATTERY CURRENT1 vs. BATTERY VOLTAGE DS1344 BATTERY CURRENT2 vs. BATTERY VOLTAGE 440 DS1343/4 toc05 EGFIL = 0, DOSF = 1, IOUT = 0mA TA = +85°C TA = +25°C 260 TA = -40°C BATTERY CURRENT (nA) BATTERY CURRENT (nA) 5.0 DS1343/4 toc04 340 DS1343/4 toc03 EGFIL = 0 DOSF = 1 IOUT = 0mA 300 240 4.5 DS1343 BATTERY CURRENT2 vs. BATTERY VOLTAGE 340 280 4.0 DS1343 BATTERY CURRENT1 vs. BATTERY VOLTAGE 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 320 3.5 SUPPLY VOLTAGE (V) 140 360 TA = -40°C 3.0 160 380 80 SUPPLY VOLTAGE (V) 220 180 90 5.5 BATTERY CURRENT (nA) BATTERY CURRENT (nA) 3.5 240 200 TA = +25°C 100 60 3.0 260 TA = +85°C 110 70 0 280 120 DS1343/4 toc06 SUPPLY CURRENT (µA) 400 CE = VIL IOUT = 0mA 130 SUPPLY CURRENT (µA) TA = +25°C CE = VIH IOUT = 0mA 500 140 DS1343/4 toc01 600 POWER-SUPPLY CURRENT vs. POWER-SUPPLY VOLTAGE DS1343/4 toc02 POWER-SUPPLY CURRENT vs. POWER-SUPPLY VOLTAGE EGFIL = 1, DOSF = 0, IOUT = 0mA 390 TA = +85°C TA = +25°C 340 290 TA = -40°C 220 240 200 Maxim Integrated 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 BATTERY VOLTAGE (V) BATTERY VOLTAGE (V)   7 DS1343/DS1344 Low-Current SPI/3-Wire RTCs Pin Configurations VCC SERMODE PF SDO SDI SCLK CE TOP VIEW 14 13 12 11 10 9 8 TOP VIEW N.C. 17 N.C. 16 SDO 6 15 SDI INT0 7 14 SCLK N.C. 8 13 N.C. INT1 9 12 CE GND 10 11 SERMODE TSSOP DS1343 DS1344 EP + 1 2 3 4 5 6 7 GND 5 PF INT1 4 X2 18 N.C. N.C. DS1343 DS1344 N.C. INT0 3 VCC 19 X2 X1 20 X1 2 VBAT 1 N.C. + VBAT TDFN (3mm × 3mm) Pin Descriptions PIN NAME FUNCTION TSSOP TDFN-EP 1 1 VBAT Battery Input for Standard +3V Lithium Cell or Other Energy Source. UL recognized to ensure against reverse charging current when used in conjunction with a primary lithium battery. 2, 4, 6, 8, 13, 17, 19 5 N.C. No Connection. N.C. pins can be connected to GND to reduce noise around the crystal inputs. 3 2 X1 5 3 X2 7 9 8   4 6 Connections for Standard 32.768kHz Quartz Crystal (see the Crystal Characteristics table). The devices can also be driven by an external 32.768kHz oscillator. In this configuration, the X1 pin is connected to the external oscillator and the X2 pin is left unconnected. INT0 Active-Low Interrupt 0 Output. INT0 is an active-low output that can be used as an interrupt output to a processor. INT0 can be programmed to be asserted by only Alarm 0, or can be programmed to be asserted by either Alarm 0 or Alarm 1. INT0 remains low as long as the status bit causing the interrupt is present and the corresponding interrupt enable bit is set. INT0 operates when the component is powered by VCC or VBAT. INT0 is an open-drain output and requires an external pullup resistor. INT1 Active-Low Interrupt 1 Output. INT1 is an active-low output that can be used either as an interrupt output to a processor or a 32kHz square-wave output. INT1 can be programmed to be asserted by Alarm 1 only. INT1 remains low as long as the status bit causing the interrupt is present and the corresponding interrupt enable bit is set. INT1 operates when the component is powered by VCC or VBAT. INT1 is an opendrain output and requires an external pullup resistor. Maxim Integrated DS1343/DS1344 Low-Current SPI/3-Wire RTCs Pin Descriptions (continued) PIN NAME FUNCTION TSSOP TDFN-EP 10 7 GND 11 13 SERMODE 12 8 CE 14 9 SCLK 15 10 SDI Serial-Data Input. When SPI communication is selected, SDI is the serial-data input for the SPI bus. When 3-wire communication is selected, this pin must be connected to SDO (SDI and SDO function as a single I/O pin when connected together). Ground Serial-Interface Mode Input. When connected to GND, standard 3-wire communication is selected. When connected to VCC, SPI communication is selected. Chip Enable. The chip-enable signal must be asserted high during a read or a write for either 3-wire or SPI communications. Serial-Clock Input. SCLK is used to synchronize data movement on the serial interface for either 3-wire or SPI communications. 16 11 SDO Serial-Data Output. When SPI communication is selected, SDO is the serial-data output for the SPI bus. When 3-wire communication is selected, this pin must be connected to SDI (SDI and SDO function as a single I/O pin when connected together). 18 12 PF Active-Low Power-Fail Output. The PF pin is used to indicate loss of the primary power supply (VCC). When VCC is less than VPF, the PF pin is driven low. 20 14 VCC — — EP Power-Supply Input Exposed Pad (TDFN Only). Connect to GND or leave unconnected. Functional Diagram 32.768kHz X1 VCC PF VBAT GND POWER CONTROL AND TRICKLE CHARGER ON_VCC X2 OSCILLATOR AND COUNTDOWN CHAIN 1Hz INT0 CLOCK, CALENDAR, AND ALARM REGISTERS DS1343 DS1344 CONTROL REGISTERS CE SCLK SDI SDO N INT1 N SERIAL INTERFACE INPUT SHIFT REGISTER USER RAM SERMODE Maxim Integrated   9 DS1343/DS1344 Low-Current SPI/3-Wire RTCs Detailed Description The DS1343/DS1344 low-current real-time clocks (RTCs) are timekeeping devices that consume an extremely low timekeeping current and also support high-ESR crystals, broadening the pool of usable crystals for the device. The devices provide a full binary-coded decimal (BCD) clock calendar that is accessed by a simple serial interface. The clock/calendar provides seconds, minutes, hours, day, date, month, and year information. The date at the end of the month is automatically adjusted for months with fewer than 31 days, including corrections for leap year through 2099. The clock operates in either a 24-hour or 12-hour format with an AM/PM indicator. In addition, 96 bytes of NV RAM are provided for data storage. The devices maintain the time and date, provided that the oscillator is enabled, as long as at least one supply is at a valid level. Both devices provide two programmable time-of-day alarms. Each alarm can generate an interrupt on a programmable combination of seconds, minutes, hours, and day. Don’t-care states can be inserted into one or more fields if it is desired for them to be ignored for the alarm condition. The time-of day alarms can be programmed to assert two different interrupt outputs or to assert one common interrupt output. Both interrupt outputs operate when the device is powered by VCC or VBAT. The devices support a direct interface to SPI serial-data ports or standard 3-wire interface. A straight-forward address and data format is implemented in which data transfers can occur one byte at a time or in multiple-byte burst mode. The devices have a built-in temperature-compensated power-sense circuit that detects power failures and automatically switches to the backup supply. The VBAT pin can be configured to provide trickle charging of a rechargeable voltage source, with selectable charging resistance and diode-voltage drops. I/O and Power-Switching Operation The devices operate as slave devices on a 3-wire or SPI serial bus. Access is obtained by selecting the part by the CE pin and clocking data into/out of the part using the SCLK and SDI/SDO pins. Multiple byte transfers are supported within one CE high period; see the Serial Peripheral Interface (SPI) section for more information. The devices are fully accessible and data can be written and read when VCC is greater than VPF. However, 10   when VCC falls below VPF, the internal clock registers are blocked from any access, and the device power is switched from VCC to VBAT. If VPF is less than the voltage on the backup supply, the device power is switched from VCC to the backup supply when VCC drops below VPF. If VPF is greater than the backup supply, the device power is switched from VCC to the backup supply when VCC drops below the backup supply. The registers are maintained from the backup supply source until VCC is returned to nominal levels. The Functional Diagram illustrates the main elements. Freshness Seal Mode When a battery is first attached to the device, the device does not immediately provide battery-backup power to the RTC or internal circuitry. After VCC exceeds VPF, the devices leave the freshness seal mode and provide battery-backup power whenever VCC subsequently falls below VBAT. This mode allows attachment of the battery during product manufacturing, but no battery capacity is consumed until after the system has been activated for the first time. As a result, minimum battery energy is used during storage and shipping. Oscillator Circuit The devices use an external 32.768kHz crystal. The oscillator circuit does not require any external resistors or capacitors to operate. The DS1343 includes integrated capacitive loading for a 6pF CL crystal, and the DS1344 includes integrated capacitive loading for a 12.5pF CL crystal. See the Crystal Parameters table for the external crystal parameters. The Functional Diagram shows a simplified schematic of the oscillator circuit. The startup time is usually less than one second when using a crystal with the specified characteristics. Clock Accuracy When running from the internal oscillator, the accuracy of the clock is dependent upon the accuracy of the crystal and the accuracy of the match between the capacitive load of the oscillator circuit and the capacitive load for which the crystal was trimmed. Additional error is added by crystal frequency drift caused by temperature shifts. External circuit noise coupled into the oscillator circuit can result in the clock running fast. Figure 1 shows a typical PCB layout for isolation of the crystal and oscillator from noise. Refer to Application Note 58: Crystal Considerations with Dallas Real-Time Clocks for detailed information. Maxim Integrated DS1343/DS1344 Low-Current SPI/3-Wire RTCs LOCAL GROUND PLANE (LAYER 2) X1 CRYSTAL X2 NOTE: AVOID ROUTING SIGNAL LINES IN THE CROSSHATCHED AREA (UPPER LEFT QUADRANT) OF THE PACKAGE UNLESS THERE IS A GROUND PLANE BETWEEN THE SIGNAL LINE AND THE DEVICE PACKAGE. GND Figure 1. Layout Example Register Map Table 1 shows the devices’ register map. During a multibyte RTC access, if the address pointer reaches the end of the register space (1Fh), it wraps around to location 00h. During a multibyte RAM access, if the address pointer reaches the end of the register space (7Fh), it wraps around to location 20h. On either the rising edge of CE or an RTC address pointer wrap around, the current time is transferred to a secondary set of registers. The time information is read from these secondary registers, while the clock continues to run. This eliminates the need to reread the registers in case the main registers update during a read. Clock and Calendar (00h–06h) The time and calendar information is obtained by reading the appropriate register bytes. Table 1 shows the RTC registers. The time and calendar are set or initialized by writing the appropriate register bytes. The contents of the time and calendar registers are in the BCD format. The Day register increments at midnight and rolls over from 7 to 1. Values that correspond to the day-of-week are user defined, but must be sequential (i.e., if 1 equals Sunday, then 2 equals Monday, and so on). Illogical time and date entries result in undefined operation. The devices can be run in either 12-hour or 24-hour mode. Bit 6 of the Hours register is defined as the 12- or 24-hour mode-select bit. When high, the 12-hour mode is selected. In the 12-hour mode, bit 5 is the AM/PM bit, with a content of 1 being PM. In the 24-hour mode, bit 5 is the 20-hour field. Changing the 12/24 mode-select bit requires that the Hours data subsequently be reentered, including the Alarm register (if used). The Century bit (bit Maxim Integrated 7 of Month) is toggled when the Years register rolls over from 99 to 00. On a power-on reset (POR), the time and date are set to 00:00:00 01/01/00 (hh:mm:ss DD/MM/YY), and the Day register is set to 01. Alarms (07h–0Eh) The devices contains two time-of-day/date alarms. Alarm 0 can be set by writing to registers 07h–0Ah. Alarm 1 can be set by writing to registers 0Bh–0Eh. The alarms can be programmed to activate the INT0 or INT1 outputs on an alarm match condition (see Table 2). Bit 7 of each of the time of day/date alarm registers are mask bits. When all the mask bits for each alarm are 0, an alarm only occurs when the values in the timekeeping registers 00h–06h match the values stored in the alarm registers. The alarms can also be programmed to repeat every second, minute, hour, or day. Configurations not listed in the table result in illogical operation. POR values are undefined. When the RTC register values match alarm register settings, the corresponding alarm flag bit (IRQF0 or IRQF1) is set to 1 in the Status register. If the corresponding alarm interrupt enable bit (A0IE or A1IE) is also set to 1 in the Control register, the alarm condition activates the output(s) defined by the INTCN bit. Upon an active alarm, clearing the associated IRQF[1:0] bit deasserts the selected interrupt output while leaving the alarm enabled for the next occurrence of a match. Alternatively, clearing the A_IE bit deasserts the output and inhibits further output activations. The alarm flags are always active, fully independent of the A_IE bit states. All alarm registers should be written to logic zero to disable the alarm matching.   11 DS1343/DS1344 Low-Current SPI/3-Wire RTCs Table 1. Register Map ADDRESS BIT 7 MSB 00h 0 10 Seconds 01h 0 10 Minutes 02h 0 12/24 AM/PM 20 Hours 10 Hours 03h 0 0 0 0 04h 0 0 05h Century BIT 6 BIT 5 BIT 3 BIT 2 RANGE Seconds Seconds 00–59 Minutes Minutes 00–59 Hours 1–12 + AM/PM 00–23 Day 1–7 Hour 0 10 Month 0 BIT 1 BIT 0 LSB FUNCTION Day 10 Date 0 06h BIT 4 Date Date 01–31 Month Month/ Century 01–12 + Century Year Year 00–99 00–59 10 Year 07h A0M1 10 Seconds Seconds Alarm 0 Seconds 08h A0M2 10 Minutes Minutes Alarm 0 Minutes 00–59 09h A0M3 12/24 AM/PM 20 Hours 10 Hours Hour Alarm 0 Hours 1–12 + AM/PM 00–23 0Ah A0M4 0 0 0 Day Alarm 0 Day 1–7 00–59 0Bh A1M1 10 Seconds Seconds Alarm 1 Seconds 0Ch A1M2 10 Minutes Minutes Alarm 1 Minutes 00–59 0Dh A1M3 Hour Alarm 1 Hours 1–12 + AM/PM 00–23 AM/PM 20 Hours 12/24 10 Hours 0Eh A1M4 0 0 0 Alarm 1 Day 1–7 0Fh X DOSF EGFIL SQW INTCN A1IE A0IE Control — 10h EOSC OSF Day 0 0 0 0 0 IRQF1 IRQF0 Status — 11h TCS3 TCS2 TCS1 TCS0 DS1 DS0 RS1 RS0 Trickle Charger — 12h–1Fh Reserved Reserved — 20h–7Fh User RAM User RAM 00h–FFh Note: Bits listed as 0 always read back as 0 and cannot be written to 1. Table 2. Alarm Mask Bits ALARM REGISTER MASK BITS (BIT 7) ALARM RATE A_M4 A_M3 A_M2 A_M1 1 1 1 1 Alarm once a second 1 1 1 0 Alarm when seconds match 1 1 0 0 Alarm when minutes and seconds match 1 0 0 0 Alarm when hours, minutes, and seconds match 0 0 0 0 Alarm when day, hours, minutes, and seconds match 12   Maxim Integrated DS1343/DS1344 Low-Current SPI/3-Wire RTCs Control Register (0Fh) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 EOSC 1 X DOSF EGFIL SQW INTCN A1IE A0IE 0 0 0 0 0 0 0 BIT 7 EOSC: Enable oscillator. During battery backup, when EOSC is set to 0, the oscillator is enabled during backup operation. When set to 1, the oscillator is stopped when the device is powered by the backup supply. This bit is set to logic 1 on the initial application of power. BIT 6 Not used. BIT 5 DOSF: Disable oscillator stop flag. When the DOSF bit is set to 1, sensing of the oscillator conditions that would set the OSF bit are disabled. OSF remains at 0 regardless of what happens to the oscillator. This bit is cleared (0) on the initial application of power. BIT 4 EGFIL: Enable glitch filter. When the EGFIL bit is 1, the 5Fs glitch filter at the output of crystal oscillator is enabled. The glitch filter is disabled when this bit is 0. This bit is cleared (0) on the initial application of power. BIT 3 SQW: Enable square wave. When the SQW bit is set to 1, a 32kHz square wave is output on the INT1 output. This bit is cleared (0) on the initial application of power. BIT 2 INTCN: Interrupt control. This bit controls the relationship between the two time-of-day alarms and the two interrupt output pins. When the INTCN bit is 1, a match between the timekeeping registers and the Alarm 0 registers activates the INT0 output (provided A0IE = 1), and a match between the timekeeping registers and the Alarm 1 registers activates the INT1 output (provided A1IE = 1). When the INTCN bit is 0, a match between the timekeeping registers and either the Alarm 0 registers or Alarm 1 registers activates the INT0 output (provided A0IE = A1IE = 1). The INT1 output has no function when INTCN = 0. The INTCN bit is cleared (0) on the initial application of power. BIT 1 A1IE: Alarm 1 interrupt enable. When A1IE is set to 0, the Alarm 1 interrupt function is disabled. When A1IE is 1, the Alarm 1 interrupt function is enabled and is routed to either INT0 (if INTCN = 0) or INT1 (if INTCN = 1). Regardless of the state of A1IE, a match between the timekeeping registers and the Alarm 1 registers (0Bh–0Eh) sets the interrupt request 1 flag bit (IRQF1). The A1IE bit is cleared (0) when power is first applied. BIT 0 A0IE: Alarm 0 interrupt enable. When A0IE is set to 0, the Alarm 0 interrupt function is disabled. When A0IE is 1, the Alarm 0 interrupt function is enabled and is routed to INT0. Regardless of the state of A0IE, a match between the timekeeping registers and the Alarm 0 registers (07h–0Ah) sets the interrupt register 0 flag bit (IRQF0). The A0IE bit is cleared (0) when power is first applied. Maxim Integrated   13 DS1343/DS1344 Low-Current SPI/3-Wire RTCs Status Register (10h) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 OSF 0 0 0 0 0 IRQF1 IRQF0 1 0 0 0 0 0 0 0 OSF: Oscillator stop flag. If the OSF bit is 1, the oscillator either has stopped or was stopped for some period and could be used to judge the validity of the clock and calendar data. This bit is edge triggered and is set to 1 when the internal circuitry senses the oscillator has transitioned from a normal run state to a stop condition. This bit remains at logic 1 until written to logic 0. Attempting to write OSF to 1 leaves the value unchanged. BIT 7 The following are examples of conditions that can cause the OSF bit to be set: 1) The first time power is applied. 2) The voltage present on VCC is insufficient to support oscillation. 3) The EOSC bit is a logic one during battery backup. 4) External influences on the crystal (i.e., noise, leakage, etc.). BIT 1 IRQF1: Interrupt request 1 flag. A logic 1 in the IRQF1 bit indicates that the time matched the Alarm 1 registers. This flag can be used to generate an interrupt on either INT0 or INT1 depending on the status of the INTCN bit in the Control register. If the INTCN bit is 0 and IRQF1 is 1 (and the A1IE bit is also 1), INT0 goes low. If the INTCN bit is 1 and IRQF1 is 1 (and the A1IE bit is also 1), INT1 goes low. IRQF1 is cleared when the address pointer is set to any of the Alarm 1 registers during an I/O transaction. The IRQF1 bit can also be cleared by writing it to 0. This bit can only be written to 0. Attempting to write the IRQF1 bit to 1 leaves the value unchanged. BIT 0 IRQF0: Interrupt request 0 flag. A logic 1 in the IRQF0 bit indicates that the time matched the Alarm 0 registers. If the A0IE bit is also 1, INT0 goes low. IRQF0 is cleared when the address pointer is set to any of the Alarm 0 registers during an I/O transaction. The IRQF0 bit can also be cleared by writing it to 0. This bit can only be written to 0. Attempting to write the IRQF0 bit to 1 leaves the value unchanged. Trickle Charger Register (11h) BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 TCS3 TCS2 TCS1 TCS0 DS1 DS0 RS1 RS0 0 0 0 0 0 0 0 0 Register 11h controls the devices’ trickle-charge characteristics. The simplified schematic of Figure 2 shows the basic components of the trickle charger. The tricklecharge select (TCS[3:0]) bits (bits 7:4) control the selection of the trickle charger. To prevent accidental enabling, only a pattern of 1010 enables the trickle charger; all other patterns disable the trickle charger. On the initial application of power, the devices power up with the trickle charger disabled. The diode-select 14   (DS[1:0]) bits (bits 3:2) select whether or not a diode is connected between VCC and VBAT. The resistor-select (RS[1:0]) bits (bits 1:0) select the resistor that is connected between VCC and VBAT. The RS and DS bits select the resistor and diodes, as shown in Table 3. The user determines diode and resistor selection according to the maximum current desired for secondary battery or super cap charging. The maximum charging current can be calculated using the equation that follows. Maxim Integrated DS1343/DS1344 Low-Current SPI/3-Wire RTCs R1 1kΩ R2 2kΩ VCC VBAT R3 4kΩ 1 0F 18 SELECT NOTE: ONLY 1010 CODE ENABLES CHARGER TRICKLE CHARGER REGISTER 1 OF 2 SELECT 1 OF 3 SELECT TCS = TRICKLE-CHARGER SELECT DS = DIODE SELECT RS = RESISTOR SELECT TCS TCS TCS TCS DS DS RS RS BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 Figure 2. Trickle Charger Block Diagram Table 3. Trickle-Charger Resistor and Diode Select TCS3 TCS2 TCS1 TCS0 DS1 DS0 RS1 RS0 FUNCTION X X X X X X X X X X 0 0 0 0 Disabled X X X X X X 1 1 X X Disabled Disabled 1 0 1 0 0 1 0 1 No diode, 1kI 1 0 1 0 0 1 1 0 No diode, 2kI 1 0 1 0 0 1 1 1 No diode, 4kI 1 0 1 0 1 0 0 1 One diode, 1kI 1 0 1 0 1 0 1 0 One diode, 2kI 1 0 1 0 1 0 1 1 One diode, 4kI 0 0 0 0 0 0 0 0 Initial power-on state—disabled X = Don’t care. Assume, for the purposes of the example, that a system power supply of 5V is applied to VCC and a super cap is connected to VBAT. Also assume that the trickle charger has been enabled with one diode and resistor R1. The maximum current IMAX would be calculated as follows: IMAX = (5.0V - diode drop)/R1 ≈ (5.0V - 0.6V)/2kΩ ≈ 2.2mA As the super cap charges, the voltage drop between VCC and VBAT decreases, and therefore, the charge current decreases. Maxim Integrated Serial Port Operation The devices offer the flexibility to choose between two serial-interface modes. The component can communicate with the SPI interface or with a standard 3-wire interface. The interface method used is determined by SERMODE. When SERMODE is connected to VCC, SPI communication is selected. When SERMODE is connected to ground, standard 3-wire communication is selected.   15 DS1343/DS1344 Low-Current SPI/3-Wire RTCs Serial Peripheral Interface (SPI) The serial peripheral interface (SPI) is a synchronous bus for address and data transfer, and is used when interfacing with the SPI bus on specific Motorola microcontrollers, such as the 68HC05C4 and the 68HC11A8. The SPI mode of serial communication is selected by connecting SERMODE to VCC. Four pins are used for the SPI. The four pins are SDO (serial-data out), SDI (serialdata in), CE (chip enable), and SCLK (serial clock). The IC is the slave device in an SPI application, with the microcontroller being the master. SDI and SDO are the serial-data input and output pins, respectively, for the device. The CE input is used to initiate and terminate a data transfer. SCLK is used to synchronize data movement between the master (microcontroller) and the slave (IC) devices. The input clock (SCLK), which is generated by the microcontroller, is active only during address and data transfer to any device on the SPI bus. The inactive clock polarity is programmable in some microcontrollers. The device determines the clock polarity by sampling SCLK when CE becomes active. Therefore, either SCLK polarity can be accommodated. Input data (SDI) is latched on the internal strobe edge and output data (SDO) is shifted out on the shift edge (Figure 3). There is one clock for each bit transferred. Address and data bits are transferred in groups of eight, MSB first. Address and Data Bytes Address and data bytes are shifted MSB first into the serial-data input (SDI) and out of the serial-data output (SDO). Any transfer requires the address of the byte to specify a write or read to either a RTC or RAM location, followed by one or more bytes of data. Data is transferred out of the SDO for a read operation and into the SDI for a write operation (Figure 4 and Figure 5). The address byte is always the first byte entered after CE is driven high. The most significant bit (R/W) of this byte determines if a read or write takes place. If R/W is 0, one or more read cycles occur. If R/W is 1, one or more write cycles occur. Data transfers can occur 1 byte at a time or in multiplebyte burst mode. After CE is driven high an address is written to the device. After the address, one or more data bytes can be written or read. For a single-byte transfer, 1 byte is read or written and then CE is driven low. For a multiple-byte transfer, however, multiple bytes can be read or written to the device after the address has been written. Each read or write cycle causes the RTC register or RAM address to automatically increment. Incrementing continues until the device is disabled. When the RTC address space is selected, the address wraps to 00h after incrementing from 1Fh. When the RAM address space is selected, the address wraps to 20h after incrementing from 7Fh. CE CPOL = 1 CPOL = 0 SCLK SHIFT DATA OUT (READ) DATA LATCH (WRITE) SCLK SHIFT DATA OUT (READ) DATA LATCH (WRITE) NOTE 1: CPHA BIT POLARITY (IF APPLICABLE) MAY NEED TO BE SET ACCORDINGLY. NOTE 2: CPOL IS A BIT THAT IS SET IN THE MICROCONTROLLER’S CONTROL REGISTER. NOTE 3: SDO REMAINS AT HIGH-Z UNTIL 8 BITS OF DATA ARE READY TO BE SHIFTED OUT DURING A READ. Figure 3. Serial Clock as a Function of Microcontroller Clock Polarity (CPOL) 16   Maxim Integrated DS1343/DS1344 Low-Current SPI/3-Wire RTCs CE SCLK* 1 SDI A6 A5 A4 R/W A3 A2 A1 A0 A3 A2 A1 A0 D7 D6 D5 D4 D3 D2 D1 D7 D6 D5 D4 D3 D2 D1 D0 HIGH-Z SDO *SCLK CAN BE EITHER POLARITY. SERMODE = VCC. Figure 4. SPI Single-Byte Write CE SCLK* 0 SDI A6 R/W SDO A5 A4 HIGH-Z D0 *SCLK CAN BE EITHER POLARITY. SERMODE = VCC. Figure 5. SPI Single-Byte Read CE SCLK WRITE SDI ADDRESS BYTE SDI ADDRESS BYTE READ SDO DATA BYTE 0 DATA BYTE 1 DATA BYTE 0 DATA BYTE 1 DATA BYTE N DATA BYTE N Figure 6. SPI Multibyte Burst Transfer Maxim Integrated   17 DS1343/DS1344 Low-Current SPI/3-Wire RTCs Reading and Writing in Burst Mode Applications Information 3-Wire Interface To achieve the best results when using the devices, decouple the VCC power supply with a 0.01µF and/or 0.1µF capacitor. Use a high-quality, ceramic, surfacemount capacitor if possible. Surface-mount components minimize lead inductance, which improves performance, and ceramic capacitors tend to have adequate highfrequency response for decoupling applications. Burst mode is similar to a single-byte read or write, except that CE is kept high and additional SCLK cycles are sent until the end of the burst. The clock registers and the user RAM can be read or written in burst mode. The address pointer wraps around to 00h after reaching 1Fh (RTC), and the address pointer wraps around to 20h after reaching 7Fh (RAM). See Figure 6. Power-Supply Decoupling The 3-wire interface mode operates similarly to the SPI mode. However, in 3-wire mode there is one I/O instead of separate data-in and data-out signals. The 3-wire interface consists of the I/O (SDI and SDO pins connected together), CE, and SCLK pins. In 3-wire mode, each byte is shifted in LSB first, unlike SPI mode, where each byte is shifted in MSB first. Using Open-Drain Outputs The INT0 and INT1 outputs are open drain and therefore require external pullup resistors to realize a logic-high output level. Battery Charge Protection The devices contain Maxim’s redundant battery-charge protection circuit to prevent any charging of an external battery. The DS1343 and DS1344 are recognized by Underwriters Laboratories (UL) under file E141114. As is the case with the SPI mode, an address byte is written to the device followed by a single data byte or multiple data bytes. Figure 7 illustrates a write cycle, and Figure 8 illustrates a read cycle. In 3-wire mode, data is input on the rising edge of SCLK and output on the falling edge of SCLK. CE SCLK I/O* HIGH-Z A0 A1 A2 A3 A4 A5 A6 1 D0 D1 D2 D3 D4 D5 D6 D7 R/W *I/O IS SDI AND SDO CONNECTED TOGETHER. SERMODE = GND. Figure 7. 3-Wire Single-Byte Write CE SCLK I/O* HIGH-Z A0 A1 A2 *I/O IS SDI AND SDO CONNECTED TOGETHER. SERMODE = GND A3 A4 A5 A6 0 D0 D1 D2 D3 D4 D5 D6 D7 R/W Figure 8. 3-Wire Single-Byte Read 18   Maxim Integrated DS1343/DS1344 Low-Current SPI/3-Wire RTCs Ordering Information PART TEMP RANGE TYP OPERATING VOLTAGE (V) OSC CL (pF) DS1343E-18+ -40NC to +85NC 1.8 6 20 TSSOP DS1343E-3+ -40NC to +85NC 3.0 6 20 TSSOP DS1343E-33+ -40NC to +85NC 3.3 6 20 TSSOP DS1343D-18+ -40NC to +85NC 1.8 6 14 TDFN-EP* DS1343D-3+ -40NC to +85NC 3.0 6 14 TDFN-EP* DS1343D-33+ -40NC to +85NC 3.3 6 14 TDFN-EP* DS1344E-18+ -40NC to +85NC 1.8 12.5 20 TSSOP DS1344E-3+ -40NC to +85NC 3.0 12.5 20 TSSOP DS1344E-33+ -40NC to +85NC 3.3 12.5 20 TSSOP DS1344D-18+ -40NC to +85NC 1.8 12.5 14 TDFN-EP* DS1344D-3+ -40NC to +85NC 3.0 12.5 14 TDFN-EP* DS1344D-33+ -40NC to +85NC 3.3 12.5 14 TDFN-EP* PIN-PACKAGE +Denotes a lead(Pb)-free/RoHS-compliant package. *EP = Exposed pad. Chip Information SUBSTRATE CONNECTED TO GROUND Maxim Integrated Package Information For the latest package outline information and land patterns (footprints), go to www.maximintegrated.com/packages. Note that a “+”, “#”, or “-” in the package code indicates RoHS status only. Package drawings may show a different suffix character, but the drawing pertains to the package regardless of RoHS status. PACKAGE TYPE PACKAGE CODE OUTLINE NO. LAND PATTERN NO. 20 TSSOP U20+1 21-0066 90-0116 14 TDFN-EP T1433+2 21-0137 90-0063   19 DS1343/DS1344 Low-Current SPI/3-Wire RTCs Revision History REVISION NUMBER REVISION DATE 0 3/11 Initial release 1 12/11 Removed future status from several DS1344 parts in the Ordering Information table; added UL recognized to the Features and Battery Charge Protection sections; added IBATLKG and DS1344 IBAT1, IBAT2 specs to the DC Electrical Characteristics section; added DS1344 Typical Operating Characteristics graphs 1, 2, 7, 18, 19 2 10/14 Added standby current and IOH and IOL for 3V and 1.8V versions, decreased active current, increased SCLK to data delay and CE OT output high impedance, and removed future product references 2, 3, 19 DESCRIPTION PAGES CHANGED — Maxim Integrated cannot assume responsibility for use of any circuitry other than circuitry entirely embodied in a Maxim Integrated product. No circuit patent licenses are implied. Maxim Integrated reserves the right to change the circuitry and specifications without notice at any time. The parametric values (min and max limits) shown in the Electrical Characteristics table are guaranteed. Other parametric values quoted in this data sheet are provided for guidance. 20 ©  2014 Maxim Integrated 160 Rio Robles, San Jose, CA 95134 USA 1-408-601-1000 Maxim Integrated Products, Inc. Maxim Integrated and the Maxim Integrated logo are trademarks of Maxim Integrated Products, Inc.
DS1344E-3+ 价格&库存

很抱歉,暂时无法提供与“DS1344E-3+”相匹配的价格&库存,您可以联系我们找货

免费人工找货
DS1344E-3+
    •  国内价格
    • 1036+30.80000

    库存:11011