0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
EVAL-AD7190EBZ

EVAL-AD7190EBZ

  • 厂商:

    AD(亚德诺)

  • 封装:

    -

  • 描述:

    BOARD EVAL FOR AD7190

  • 数据手册
  • 价格&库存
EVAL-AD7190EBZ 数据手册
UG-222 Evaluation Board User Guide One Technology Way • P.O. Box 9106 • Norwood, MA 02062-9106, U.S.A. • Tel: 781.329.4700 • Fax: 781.461.3113 • www.analog.com Evaluation Board for the AD7190/AD7192 4.8 kHz Ultralow Noise 24-Bit Sigma-Delta ADCs FEATURES GENERAL DESCRIPTION Full-featured evaluation board for the AD7190/AD7192 Standalone interface using microcontroller and LCD display PC software for control of AD7190/AD7192 using USB interface Various linking options The AD7190/AD7192 evaluation kit is a powerful tool for exploring and evaluating the AD7190/AD7192 features. INTRODUCTION When the board is connected to (and possibly powered from) a PC via a standard USB interface, the PC software allows the graphical display of real-time data, logs them into a text file, allows you to modify the AD7190/AD7192 internal settings, and generally helps in understanding the part features and performance. The evaluation board can be operated in complete standalone, battery-powered mode. The LCD display is used to display the conversion data. This user guide describes the evaluation board for the AD7190/ AD7192, which are 4.8 kHz ultralow noise 24-bit sigma-delta (Σ-Δ) ADCs. The AD7190/AD7192 are complete analog front ends for low frequency measurement applications. The parts contain two differential inputs/four pseudo differential inputs, and include a low noise instrumentation amplifier, reference detect, and a low-side power switch. Finally, the board’s flexible interface structure allows it to be connected in a number of useful configurations. For example, the digital section of the evaluation board can be used independently as a convenient digital interface for a user’s own sensor design PCB or module containing the AD7190/AD7192. Alternatively, an external microcontroller can be interfaced to the AD7190/AD7192 and thus the evaluation board can act as a complete analog front end for creating and debugging software on the user’s own digital platform. Full data on the AD7190/AD7192 is available in the AD7190 and AD7192 data sheets available from Analog Devices, Inc., and should be consulted in conjunction with this user guide when using the evaluation board. BATT EXT VOLTAGE REGULATOR VOLTAGE REGULATOR NOISE TEST CIRCUITRY ANALOG INPUTS AD7190/ AD7192 PC AND LabVIEW™ BASED SOFTWARE SPI/USB INTERFACE MICRO VOLTAGE REFERENCE DRIVERS REFIN Figure 1. AD7190/AD7192 Evaluation Board PLEASE SEE THE LAST PAGE FOR AN IMPORTANT WARNING AND LEGAL TERMS AND CONDITIONS. Rev. 0 | Page 1 of 20 LCD 09551-001 SENSOR CONNECTOR UG-222 Evaluation Board User Guide TABLE OF CONTENTS Features .............................................................................................. 1  Software Installation .....................................................................6  Introduction ...................................................................................... 1  Evaluation Software Installation .................................................6  General Description ......................................................................... 1  Evaluation Board Installation ......................................................6  Revision History ............................................................................... 2  Using the Software ........................................................................6  Evaluation Board Hardware ............................................................ 3  Main Window ................................................................................7  Power Supplies .............................................................................. 3  ADC Setup .....................................................................................8  Sockets ........................................................................................... 3  Configuration Assist Tool ............................................................9  Noise Test....................................................................................... 4  Low Noise Quick Test ................................................................ 10  Using an Absolute Reference ...................................................... 4  WeighScale Demo ...................................................................... 11  Connecting the AD7190/AD7192 to an External Microcontroller............................................................................. 4  User Units Setup......................................................................... 12  Evaluation Board schematics and Artwork ................................ 13  Using the AD7190/AD7192 Evaluation Board in Standalone Mode................................................................................................... 5  Ordering Information.................................................................... 17  Using the AD7190/AD7192 Evaluation Board with the PC Software ............................................................................................. 6  Related Links................................................................................... 18  Bill of Materials........................................................................... 17  REVISION HISTORY 12/10—Revision 0: Initial Version Rev. 0 | Page 2 of 20 Evaluation Board User Guide UG-222 EVALUATION BOARD HARDWARE POWER SUPPLIES There are several power supply options on the AD7190/AD7192 evaluation board. Connected to USB Connector The AD7190/AD7192 evaluation board is powered via the 5 V supply from the USB connector, J51. This 5 V supply can be used to power the AD7190/AD7192 directly. Link J1 should be placed in Position 5 V USB. The 5 V supply from the USB connector can be regulated to 3.3 V using the on-board ADP3303-3, a high precision, low power, 3.3 V output voltage regulator. Therefore, using Link J1, the 3.3 V can be used as the power supply to the AD7190/AD7192. Link J1 should be placed in Position 3.3 V. The AD7190/AD7192 can be powered using a 9 V battery, B1, or using an external 9 V dc source connected at J31. The 9 V is regulated down to 5 V using the on-board ADP3303-5, a high precision, low power 5 V output regulator. Using Link J1, this regulated 5 V can be used as the supply to the AD7190/AD7192. To use this option, Link J1 should be placed in Position 5 V BAT. An external power supply can be applied via J10. Link J1 should be placed in Position EXT. Standalone Operation The AD7190/AD7192 evaluation board can be powered using a 9 V battery, B1, or using an external 9 V dc source connected at J31. The 9 V is regulated down to 5 V using the on-board ADP3303-5, a high precision, low power 5 V output regulator. Using Link J1, this regulated 5 V can be used as the supply to the AD7190/AD7192. To use this option, Link J1 should be placed in Position 5 V BAT. An external power supply can be applied via J10. Link J1 should be placed in Position EXT. SOCKETS There are five sockets relevant to the operation of the AD7190/ AD7192 on this evaluation board. The functions of these sockets are outlined in Table 1. Table 1. Socket Functions Socket REF2+ REF2− AIN1 AIN2 MCLK Description Subminiature BNC (SMB) connector. This socket is used in conjunction with REFIN2− to apply an external reference to the AD7190/AD7192. The voltage for the REFIN2(+) input of the AD7190/AD7192 is applied to this socket. Subminiature BNC (SMB) connector. This socket is used in conjunction with REFIN2+ to apply an external reference to the AD7190/AD7192. The voltage for the REFIN2(−) input of the AD7190/AD7192 is applied to this socket. Subminiature BNC (SMB) connector. This socket is used to apply an analog input signal to AIN1. Subminiature BNC (SMB) connector. This socket is used to apply an analog input signal to AIN2. Subminiature BNC (SMB) connector. An external clock source can be applied to the AD7190/AD7192 using this socket. Rev. 0 | Page 3 of 20 UG-222 Evaluation Board User Guide J3 Figure 2. Link Positions for Noise Testing 09551-004 VREF REF2+ REF2– AGND AINCOM AIN2 AIN1 09551-002 J3 AVDD VREF REF2+ REF2– AGND AINCOM An ADR421 is included on the AD7190/AD7192 evaluation board so that the part can also be evaluated using an absolute reference. The reference can be connected to the REFIN2(+) and REFIN2(−) pins of the AD7190/AD7192 by connecting the links of Header J3, as shown in Figure 4. AIN2 Header J3 allows the user to perform noise testing of the AD7190/AD7192. With all links in the vertical position (see Figure 2), the analog and reference are applied to the AD7190/AD7192, as shown in Figure 3. AIN1 USING AN ABSOLUTE REFERENCE AVDD NOISE TEST Figure 4. Connecting an Absolute Reference to the AD7190/AD7192 AVDD CONNECTING THE AD7190/AD7192 TO AN EXTERNAL MICROCONTROLLER AVDD The AD7190/AD7192 evaluation board can be connected to an external microcontroller using Header J2. With all links in place, the AD7190/AD7192 are connected to the on-board microcontroller. However, with these links removed, the AD7190/AD7192 are disconnected from the evaluation board microcontroller. The user can then use a header to interface the AD7190/AD7192 to the external microcontroller. REFIN2(+) 1kΩ AIN1 AIN2 AD7190/ AD7192 1kΩ AINCOM REFIN2(–) 09551-003 100Ω Figure 3. Noise Test Connections As shown in Figure 3, inserting the links in Header J3 connects a resistor network to the AD7190/AD7192. The reference to the ADC is provided by AVDD. The resistor divider generates a bias voltage of approximately AVDD/2. Channel AIN1 and Channel AIN2 are connected to this voltage. Therefore, conversions can now be performed using this external short to measure the rms noise, peak-to-peak noise, and peak-to-peak resolution. Rev. 0 | Page 4 of 20 Evaluation Board User Guide UG-222 USING THE AD7190/AD7192 EVALUATION BOARD IN STANDALONE MODE The AD7190/AD7192 evaluation board can be operated in standalone mode. In this mode, the evaluation board functions as a weigh scale demonstration. Channel AIN3/AIN4 is the analog input channel with REFIN1(+)/REFIN1(−) as the reference source. These analog input pins and reference pins are connected to the J4 header along with AVDD and GND. This header allows the user to connect a load cell to the AD7190/ AD7192. The load cell should be connected to the header, as shown in Figure 5. A 6-wire load cell is shown, but a 4-wire load cell can also be connected. EXC+ SENSE+ GND/SHLD AVDD/EXC REF1(+) OUT+ AIN3(+) AIN4(–) OUT– REF1– GND/SHLD EXC– J4 09551-005 PWR_SW SENSE– Figure 5. Load Cell Connection to Header J4 The AD7190/AD7192 are configured for an output data rate of 4.69 Hz. The gain is programmed to 128. Channel AIN3/AIN4 is selected as the active channel with REFIN1(+)/REFIN1(−) selected as the reference source. The conversions from the AD7190/AD7192 are displayed on the LCD display. The four buttons beneath the LCD display allow the user to calibrate the weigh scale system, adjust the LCD contrast, and display the results in code or weight. The function of each button is listed at the bottom of the LCD display. To operate the weigh scale demonstration, connect the load cell to Header J4 as shown in Figure 5. Apply power to the AD7190/ AD7192 evaluation board using either a 9 V battery or a 9 V dc power source. Ensure that Link J1 is in Position 5 V BAT/EXT. The weigh scale demonstration can also be powered from the USB connector if the board is connected to a PC. Link J1 should be in Position 5 V USB in this case. With no weight on the weigh scale, an offset calibration should be performed (selectable from the buttons below the LCD display). The expected full-scale weight should then be placed on the load cell and the full-scale calibration performed. The user should select the corresponding full-scale weight on the LCD display as the weigh scale demonstration supports fullscale weights of 500 g to 10 kg. The software then continuously reads conversions from the AD7190/AD7192, scales the conversions appropriately, and displays the resulting weight on the LCD display. Rev. 0 | Page 5 of 20 UG-222 Evaluation Board User Guide USING THE AD7190/AD7192 EVALUATION BOARD WITH THE PC SOFTWARE SOFTWARE INSTALLATION EVALUATION BOARD INSTALLATION The AD7190/AD7192 evaluation board software should be installed before connecting the AD7190/AD7192 evaluation board to the PC. To install the evaluation board, 1. EVALUATION SOFTWARE INSTALLATION To install the evaluation software, perform the following steps: 2. 3. Insert the AD7190/AD7192 evaluation kit CD in the CDROM drive of your PC. The Evaluation software installation wizard should start automatically after inserting the CD. If the wizard does not start, navigate to the AD7190/AD7192 evaluation kit CD on your PC and start Setup.exe. At the prompt, select a destination directory, which is C:\Program Files\Analog Devices\AD7190/AD7192 by default. After the directory is selected, the installation procedure copies the files into the relevant directories on the hard drive. The installation program creates a program group called Analog Devices with the subgroup AD7190/AD7192 in the Start menu of the taskbar. When the installation procedure is complete, double-click the AD7190/AD7192 icon to start the program. 2. USING THE SOFTWARE Start the AD7190/AD7192 evaluation software on the PC. Click on the Windows® Start button, then click All Programs, Analog Devices, AD7190/AD7192, and finally AD7190/AD7192 evaluation software. The software allows you to configure the AD7190/AD7192, gather samples, and analyze the data. Consult the AD7190/ AD7192 data sheets for further information on the register bits and their functions. Figure 6 shows the main window that is displayed when the program starts. The Main Window section briefly describes the various menu and button options in the main window. The data that has been read can be exported to other packages, such as MathCAD™ or Microsoft® Excel®, for further analysis. 09551-006 1. Connect the AD7190/AD7192 evaluation board to your PC USB connector using the USB cable included in the evaluation kit. The POWER LED on the evaluation board should turn on and Found new hardware wizard should start automatically on the PC. Follow the steps in the wizard until the installation is completed. Figure 6. AD7190/AD7192 Evaluation Software Main Window Rev. 0 | Page 6 of 20 Evaluation Board User Guide UG-222 DATA Display Units MAIN WINDOW Menu Bar File This allows you to write the current set of data to a file for later use, log data as it is gathered, and exit the program. Board This allows you to display the conversions in hexadecimal, decimal, volts or in user-specified units. If the conversions are displayed in volts, the value of the reference voltage must be entered in the Vref box. Autoscale This allows you to alter the contrast on the LCD display. This allows you to enable or disable the autoscale function on the waveform plot. Buttons Delete Data/Clear Graphs X-scale This allows you to delete the data displayed in the graphs. This allows you to have a fixed x-axis or a dynamic x-axis. When the x-axis is fixed, the number of samples to display is entered in the X-Scale Samples box. ADC Reset This allows you to reset the AD7190/AD7192 to its default (power-on) settings. ANALYSIS Channel ADC Setup This opens the ADC Setup window, which allows you to configure the AD7190/AD7192. The data channel to be analyzed is selected using this button. Low Noise Quick Test The software can process the conversions as they are being gathered or it can process the samples when the ADC has completed the selected number of conversions. After Sampling This allows you to access the noise testing software. WeighScale Demo Analyse All Samples This allows you to access the weigh scale demonstration software. This feature allows you to fix the sample size used for analyzing. Alternatively, the software can process all samples gathered. When the Analyse Last # Samples option is selected, the sample size must be entered in the Last # Samples box. This allows you to change the display units on the graph and histogram. Sampling This allows you to sample continuously or to sample a specific number of samples. When the Sampling: Capture Defined Sample Set option is selected, the sample size is entered in the Samples box. The software captures all samples generated by the AD7190/AD7192. If the software fails to gather all samples, then the message shown in Figure 7 appears. 09551-007 User Units Setup Figure 7. Error Message When Samples Not Captured Start Sampling The software may drop samples for the following reasons: This allows you to read samples from the AD7190/AD7192. • • • Rev. 0 | Page 7 of 20 The data is being analyzed in parallel with the gathering of samples. You should delay the analysis until the samples are gathered. Other programs are running on the PC. The PC is too slow. UG-222 Evaluation Board User Guide 09551-008 ADC SETUP Figure 8. ADC Setup Window The ADC Setup window gives you access to the AD7190/ AD7192 registers. You can write to the registers and read from the registers. This window operates even when an AD7190/ AD7192 evaluation board is not connected to the software. It operates as an AD7190/AD7192 configuration tool. of the first filter notch and the software calculates the value to be written to Bits FS[9:0] of the mode register. Alternatively, you can enter the FS[9:0] value in decimal and the software calculates the first filter notch. ADC Reset The value to be written to the AD7190/AD7192 is displayed in the Registers HEX section. The ADC is reset to its default condition using this button. Voltage Reference ADC Read The reference source and reference value are programmed in this section. You can select REFIN1 or REFIN2, enable or disable the reference detect function, and set the voltage of the reference. Click this button to read the values of the registers on the AD7190/AD7192. The ADC Setup window displays the hexadecimal values returned from the AD7190/AD7192. The other sections of the ADC Setup window are also updated to reflect the AD7190/AD7192 configuration. When the reference setup is changed, the changes to the configuration register are shown in the Registers HEX section. ADC Write Clock Configuration Click this button to write the information displayed in the Registers HEX window to the AD7190/AD7192. The clock to be used by the AD7190/AD7192 is selected in this section. When an external master clock is selected, the clock frequency must be entered in the MHz box. Analog Inputs Select the analog input channels using the Channel Selection buttons. The gain, polarity, and chopping can also be selected. The analog inputs can be buffered or unbuffered using the Buffer button. Finally, the Diagnostic button enables/disables the burnout currents. Digital Outputs Digital Filter This button allows you to select various modes of operation, including continuous conversion, single cycle conversion, and calibration. The output data rate, first filter notch, the order of the sinc filter, zero latency, and enabling/disabling the REJ60 bit are programmed using these buttons. You can enter the frequency The four digital outputs, P0 to P3, are programmed and enabled/disabled in this section. The low-side power switch is also controlled in this section using the Power Switch button. Mode of Operation Rev. 0 | Page 8 of 20 Evaluation Board User Guide UG-222 Output Data Format This section allows you to select the output format of the data conversions and to enable the parity. When several analog inputs are enabled, the Data + Status option should be selected under Data Only. Registers HEX This window displays the values to be written to the AD7190/ AD7192 registers. When features such as the analog input channel, gain, and mode of operation are changed, the values in the Register HEX section are updated automatically. You can write directly to the Registers HEX section, altering the contents of any register. When the values in this section are altered, the other sections of the ADC Setup window are updated to reflect the changes. The message shown in Figure 9 appears. Click the Ignore button. The ADC Setup window opens. You can use the ADC Setup window to determine the values to be written to the AD7190/AD7192 on-chip registers for different configurations. When you change the configuration (for example, the gain or channel), the values in the Register HEX section are updated automatically. You can manually alter the values in the Registers HEX section as well. When the values in this section are altered, the other sections of the ADC Setup window are updated so that you can easily see the impact of the register changes. The AD7190/AD7192 evaluation software can be used as a configuration assist tool, even when an AD7190/AD7192 evaluation board is not connected. When the AD7190/AD7192 evaluation board software is open, click the ADC Setup button. Rev. 0 | Page 9 of 20 09551-009 CONFIGURATION ASSIST TOOL Figure 9. Configuration Tool UG-222 Evaluation Board User Guide 09551-010 LOW NOISE QUICK TEST Figure 10. Low Noise Quick Test When the Low Noise Quick Test button in the main window (see Figure 6) is clicked, you can quickly and easily measure the rms noise of the AD7190/AD7192. The software configures the AD7190/AD7192 to have a gain of 128 and an output data rate of 4.7 Hz, Channel AIN1/AIN2 is selected, and the reference voltage is set to 5 V. (The software assumes that the 5 V from the USB is used as the reference to the AD7190/AD7192.) The software also provides instructions on the link positions for the AD7190/AD7192 evaluation board. When the instructions given in each window are completed, click the OK button. The AD7190/AD7192 software gathers 100 samples, displays the results in the waveform, and analyzes the data to calculate the maximum conversion, minimum conversion, and average conversion. The rms noise, peak-to-peak noise, and resolution are also calculated. Rev. 0 | Page 10 of 20 Evaluation Board User Guide UG-222 09551-011 WEIGHSCALE DEMO Figure 11. Weigh Scale Demo A load cell can be connected directly to the AD7190/AD7192 evaluation board. When the WeighScale Demo button in the main window (see Figure 6) is clicked, you are guided through a series of windows that give information on connecting the load cell to the AD7190/AD7192 evaluation board. The AD7190/ AD7192 device is automatically configured to have a gain of 128, Channel AIN3/AIN4 is selected, and the output data rate is programmed to 10 Hz. When the instructions given in each window are completed, click OK. The AD7190/AD7192 evaluation board gathers samples continuously and uses batches of 20 samples to analyze the data. The software displays the maximum voltage measured, the average voltage, the minimum voltage, the rms noise, and resolution. The sample size used to process the data can be altered using the Last # Samples box. Rev. 0 | Page 11 of 20 UG-222 Evaluation Board User Guide 09551-012 USER UNITS SETUP Figure 12. User Units Setup Window The User Units Setup window, which is accessed by clicking the User Units Setup button in the main window (see Figure 6), allows you to define the display units for the conversions. For example, if a load cell is connected to the AD7190/AD7192, the conversions from the ADC can be displayed in grams. The offset and gain error of the system can also be calibrated. You can perform a system offset and system full-scale calibration. The resulting coefficients are held in memory; they are not written to the ADC calibration registers. Rev. 0 | Page 12 of 20 Evaluation Board User Guide UG-222 EVALUATION BOARD SCHEMATICS AND ARTWORK 09551-017 Figure 13. EVAL-AD7190EBZ/EVAL-AD7192EBZ Schematic, Analog Rev. 0 | Page 13 of 20 UG-222 Evaluation Board User Guide 09551-016 Figure 14. EVAL-AD7190EBZ/EVAL-AD7192EBZ Schematic, Digital Rev. 0 | Page 14 of 20 UG-222 09551-013 Evaluation Board User Guide 09551-014 Figure 15. EVAL-AD7190EBZ/EVAL-AD7192EBZ Component Side View Figure 16. EVAL-AD7190EBZ/EVAL-AD7192EBZ Silkscreen Rev. 0 | Page 15 of 20 Evaluation Board User Guide 09551-015 UG-222 Figure 17. EVAL-AD7190EBZ/EVAL-AD7192EBZ Solder Side View Rev. 0 | Page 16 of 20 Evaluation Board User Guide UG-222 ORDERING INFORMATION BILL OF MATERIALS Table 2. Qty. 1 1 1 1 1 1 1 1 4 5 1 Reference Designator U1 U2 U31 U32 U50 U51 U52 U53 LED1 to LED3, LED51 LED4 to LED8 XTAL1 XTAL51 D1 D31 to D34 Q51 C1 to C7, C15, C16 C52, C53 C8, C10, C11, C13 C19 to C24, C31 to C33, C54 to C61 C9, C12, C14 C34 to C37, C50, C51 C17, C18, C2,5 C30 L1 R1, R2, R5 R3, R4, R8, R20 to R25 R6, R7, R52 to R54 R9 to R15, R19, R50, R51 R16 R17, R75, R76 R18, R55 to R57, R62 to R73 R31, R32 R74 S1 to S5 B1 J1 J2, J3 J4 J5 to J9 J10 J31 J51 J52 U53 1 N/A 1 1 4 1 9 2 4 17 3 6 4 1 3 9 5 10 1 16 2 1 5 1 1 2 1 1 1 1 Description AD7190/AD7192 ADR421 reference 5 V voltage regulator 3.3 V voltage regulator 10 kΩ, 64-step digital potentiometer USB controller 64K I2C EEPROM LCD connector LED red, high intensity (>90 mCd), 0603 LED green, high intensity (>50 mCd), 0603 4.9152 MHz crystal 24 MHz crystal Diode Diode N-MOSFET Capacitor ceramic 12 pF ceramic capacitor 0.01 μF ceramic capacitor 0.1 μF ceramic capacitor Manufacturer Analog Devices Analog Devices Analog Devices Analog Devices Analog Devices Cypress Semiconductor Microchip Technology, Inc. FCI Avago Technology Avago Technology Not inserted AVX On Semiconductor Philips Infineon Not inserted Phycomp Phycomp Phycomp Order No. AD7190BRUZ/AD7192BRUZ ADR421BRZ ADP3303ARZ-5 ADP3303ARZ-3.3 AD5258BRMZ10 CY7C68013A-56LFXC 24LC64-I/SN 76341-308LF HSMC-C191 HSME-C191 Not inserted CX5032GB24000H0PESZZ P6SMB68AT3G BAT721C BSS138N Not inserted 2238 867 15129 2238 586 15636 2238 786 15649 1 μF ceramic capacitor 4.7 μF ceramic capacitor 10 μF tantalum capacitor Ferrite bead 0 Ω resistor 100 Ω resistor 1 kΩ resistor 10 kΩ resistor 1.5 Ω resistor Resistor 100 kΩ resistor Phycomp Phycomp AVX Tyco Phycomp Phycomp Phycomp Phycomp Phycomp Not inserted Phycomp 2238 246 13663 2255 206 13672 TAJA106M016R BMB2A1000LN2 232270296001 232270461001 232270461002 232270461003 232270461508 Not inserted 232270461004 10 Ω resistor 47 Ω resistor Switch Clip for 9 V battery 2 × 4-way header 2 × 8-way header 1 × 8-way header Connector, 50 Ω, straight, SMB Screw terminal block Connector, power jack, barrel, 2.1 mm, SMD Connector, USB Mini-B, SMD Header LCD module 2×16 character count, 1 × 16-pin, top LCD header Phycomp Phycomp Omron Keystone Tyco Electronics/Amp Tyco Electronics/Amp Phoenix Contact Not inserted Phoenix Contact Lumberg Molex Not inserted Everbouquet 232270461009 232270464709 B3S-1000 593+594 1241050-4 1241050-8 1803332 Not inserted 1727010 1613_14 548190572 Not inserted MC1602C-SYR Tyco 1-826629-6 Rev. 0 | Page 17 of 20 UG-222 Evaluation Board User Guide RELATED LINKS Resource AD7190 AD7192 ADP3303 ADR421 AD5258 Description Product Page, AD7190 4.8 kHz Ultralow Noise 24-Bit Sigma-Delta ADC with PGA Product Page, AD7192 4.8 kHz Ultralow Noise 24-Bit Sigma-Delta ADC with PGA Product Page, ADP3303 High Accuracy anyCAP® 200 mA Low Dropout Linear Regulator Product Page, ADR421 Ultraprecision, Low Noise, 2.500 V XFET® Voltage References Product Page, AD5258 Nonvolatile, I2C®-Compatible 64-Position, Digital Potentiometer Rev. 0 | Page 18 of 20 Evaluation Board User Guide UG-222 NOTES Rev. 0 | Page 19 of 20 UG-222 Evaluation Board User Guide NOTES ESD Caution ESD (electrostatic discharge) sensitive device. Charged devices and circuit boards can discharge without detection. Although this product features patented or proprietary protection circuitry, damage may occur on devices subjected to high energy ESD. Therefore, proper ESD precautions should be taken to avoid performance degradation or loss of functionality. Legal Terms and Conditions By using the evaluation board discussed herein (together with any tools, components documentation or support materials, the “Evaluation Board”), you are agreeing to be bound by the terms and conditions set forth below (“Agreement”) unless you have purchased the Evaluation Board, in which case the Analog Devices Standard Terms and Conditions of Sale shall govern. Do not use the Evaluation Board until you have read and agreed to the Agreement. Your use of the Evaluation Board shall signify your acceptance of the Agreement. This Agreement is made by and between you (“Customer”) and Analog Devices, Inc. (“ADI”), with its principal place of business at One Technology Way, Norwood, MA 02062, USA. Subject to the terms and conditions of the Agreement, ADI hereby grants to Customer a free, limited, personal, temporary, non-exclusive, non-sublicensable, non-transferable license to use the Evaluation Board FOR EVALUATION PURPOSES ONLY. Customer understands and agrees that the Evaluation Board is provided for the sole and exclusive purpose referenced above, and agrees not to use the Evaluation Board for any other purpose. Furthermore, the license granted is expressly made subject to the following additional limitations: Customer shall not (i) rent, lease, display, sell, transfer, assign, sublicense, or distribute the Evaluation Board; and (ii) permit any Third Party to access the Evaluation Board. As used herein, the term “Third Party” includes any entity other than ADI, Customer, their employees, affiliates and in-house consultants. The Evaluation Board is NOT sold to Customer; all rights not expressly granted herein, including ownership of the Evaluation Board, are reserved by ADI. CONFIDENTIALITY. This Agreement and the Evaluation Board shall all be considered the confidential and proprietary information of ADI. Customer may not disclose or transfer any portion of the Evaluation Board to any other party for any reason. Upon discontinuation of use of the Evaluation Board or termination of this Agreement, Customer agrees to promptly return the Evaluation Board to ADI. ADDITIONAL RESTRICTIONS. Customer may not disassemble, decompile or reverse engineer chips on the Evaluation Board. Customer shall inform ADI of any occurred damages or any modifications or alterations it makes to the Evaluation Board, including but not limited to soldering or any other activity that affects the material content of the Evaluation Board. Modifications to the Evaluation Board must comply with applicable law, including but not limited to the RoHS Directive. TERMINATION. ADI may terminate this Agreement at any time upon giving written notice to Customer. Customer agrees to return to ADI the Evaluation Board at that time. LIMITATION OF LIABILITY. THE EVALUATION BOARD PROVIDED HEREUNDER IS PROVIDED “AS IS” AND ADI MAKES NO WARRANTIES OR REPRESENTATIONS OF ANY KIND WITH RESPECT TO IT. ADI SPECIFICALLY DISCLAIMS ANY REPRESENTATIONS, ENDORSEMENTS, GUARANTEES, OR WARRANTIES, EXPRESS OR IMPLIED, RELATED TO THE EVALUATION BOARD INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTY OF MERCHANTABILITY, TITLE, FITNESS FOR A PARTICULAR PURPOSE OR NONINFRINGEMENT OF INTELLECTUAL PROPERTY RIGHTS. IN NO EVENT WILL ADI AND ITS LICENSORS BE LIABLE FOR ANY INCIDENTAL, SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES RESULTING FROM CUSTOMER’S POSSESSION OR USE OF THE EVALUATION BOARD, INCLUDING BUT NOT LIMITED TO LOST PROFITS, DELAY COSTS, LABOR COSTS OR LOSS OF GOODWILL. ADI’S TOTAL LIABILITY FROM ANY AND ALL CAUSES SHALL BE LIMITED TO THE AMOUNT OF ONE HUNDRED US DOLLARS ($100.00). EXPORT. Customer agrees that it will not directly or indirectly export the Evaluation Board to another country, and that it will comply with all applicable United States federal laws and regulations relating to exports. GOVERNING LAW. This Agreement shall be governed by and construed in accordance with the substantive laws of the Commonwealth of Massachusetts (excluding conflict of law rules). Any legal action regarding this Agreement will be heard in the state or federal courts having jurisdiction in Suffolk County, Massachusetts, and Customer hereby submits to the personal jurisdiction and venue of such courts. The United Nations Convention on Contracts for the International Sale of Goods shall not apply to this Agreement and is expressly disclaimed. ©2010 Analog Devices, Inc. All rights reserved. Trademarks and registered trademarks are the property of their respective owners. UG09551-0-12/10(0) Rev. 0 | Page 20 of 20
EVAL-AD7190EBZ 价格&库存

很抱歉,暂时无法提供与“EVAL-AD7190EBZ”相匹配的价格&库存,您可以联系我们找货

免费人工找货