HMC832LP6GE

HMC832LP6GE

  • 厂商:

    AD(亚德诺)

  • 封装:

    QFN40_6X6MM_EP

  • 描述:

    小数 N 分频锁相环,集成电压控制振荡器,频率范围为 25 MHz 至 3000 MHz

  • 数据手册
  • 价格&库存
HMC832LP6GE 数据手册
Fractional-N PLL with Integrated VCO 25 MHz to 3000 MHz HMC832 Data Sheet FEATURES FUNCTIONAL BLOCK DIAGRAM LD/SDO SCK SDI RF bandwidth: 25 MHz to 3000 MHz 3.3 V supply Maximum phase detector rate: 100 MHz Ultralow phase noise −110 dBc/Hz in band, typical Fractional figure of merit (FOM): −226 dBc/Hz 24-bit step size, resolution 3 Hz typical Exact frequency mode with 0 Hz frequency error Fast frequency hopping 40-lead 6 mm × 6 mm SMT package: 36 mm2 HMC832 LOCK DETECT CONTROL SPI PROGRAMMING INTERFACE SEN EN MODULATOR CAL RF_P EN RF_N ÷1, 2, 4, 6, ...62 APPLICATIONS ÷N VCO CP CP PFD VTUNE ÷R 12827-001 Cellular infrastructure Microwave radio WiMax, WiFi Communications test equipment CATV equipment DDS replacement Military Tunable reference source for spurious-free performance XREFP Figure 1. GENERAL DESCRIPTION The HMC832 is a 3.3 V, high performance, wideband, fractional-N, phase-locked loop (PLL) that features an integrated voltage controlled oscillator (VCO) with a fundamental frequency of 1500 MHz to 3000 MHz, and an integrated VCO output divider (divide by 1/2/4/6/…60/62), that enables the HMC832 to generate continuous frequencies from 25 MHz to 3000 MHz. The integrated phase detector (PD) and delta-sigma (Δ-Σ) modulator, capable of operating at up to 100 MHz, permit wider loop bandwidths and faster frequency tuning with excellent spectral performance. Industry leading phase noise and spurious performance, across all frequencies, enable the HMC832 to minimize blocker effects, and to improve receiver sensitivity and transmitter spectral purity. A low noise floor (−160 dBc/Hz) eliminates any contribution to modulator/mixer noise floor in transmitter applications. Rev. A The HMC832 is footprint-compatible to the market leading HMC830 PLL with integrated VCO. It features 3.3 V supply and an innovative programmable performance technology that enables the HMC832 to tailor current consumption and corresponding noise floor performance to individual applications by selecting either a low current consumption mode or a high performance mode for an improved noise floor performance. Additional features of the HMC832 include 12 dB of RF output gain control in 1 dB steps; output mute function to automatically mute the output during frequency changes when the device is not locked; selectable output return loss; programmable differential or single-ended outputs, with the ability to select either output in single-ended mode; and a Δ-Σ modulator exact frequency mode that enables users to generate output frequencies with 0 Hz frequency error. Document Feedback Information furnished by Analog Devices is believed to be accurate and reliable. However, no responsibility is assumed by Analog Devices for its use, nor for any infringements of patents or other rights of third parties that may result from its use. Specifications subject to change without notice. No license is granted by implication or otherwise under any patent or patent rights of Analog Devices. Trademarks and registered trademarks are the property of their respective owners. One Technology Way, P.O. Box 9106, Norwood, MA 02062-9106, U.S.A. Tel: 781.329.4700 ©2014 Analog Devices, Inc. All rights reserved. Technical Support www.analog.com HMC832 Data Sheet TABLE OF CONTENTS Features .............................................................................................. 1  PLL Register Map ........................................................................... 36  Applications ....................................................................................... 1  ID, Read Address, and RST Registers ...................................... 36  Functional Block Diagram .............................................................. 1  General Description ......................................................................... 1  Reference Divider, Integer, and Fractional Frequency Registers ....................................................................................... 36  Revision History ............................................................................... 2  VCO SPI Register ....................................................................... 37  Specifications..................................................................................... 3  Delta-Sigma Configuration....................................................... 37  Timing Specifications .................................................................. 5  Lock Detect Register .................................................................. 38  Absolute Maximum Ratings............................................................ 6  Analog Enable (EN) Register .................................................... 38  Recommended Operating Conditions ...................................... 6  Charge Pump Register ............................................................... 39  ESD Caution .................................................................................. 6  Autocalibration Register............................................................ 39  Pin Configuration and Function Descriptions ............................. 7  Phase Detector (PD) Register ................................................... 40  Typical Performance Characteristics ............................................. 8  Exact Frequency Mode Register ............................................... 40  Theory of Operation ...................................................................... 14  General-Purpose, Serial Port Interface, and Reference Divider (GPO_SPI_RDIV) Register ........................................ 41  PLL Subsystem Overview .......................................................... 14  VCO Subsystem Overview ........................................................ 14  SPI (Serial Port Interface) Configuration of PLL and VCO Subsystems................................................................................... 14  VCO Tune Register .................................................................... 42  SAR Register ............................................................................... 42  General-Purpose 2 Register ...................................................... 42  VCO Subsystem .......................................................................... 16  Built-In Self Test Register .......................................................... 42  PLL Subsystem ............................................................................ 20  VCO Subsystem Register Map ...................................................... 43  Soft Reset and Power-On Reset ................................................ 28  VCO Enable Register ................................................................. 43  Power-Down Mode .................................................................... 29  VCO Output Divider Register .................................................. 44  General-Purpose Output (GPO) Pin ....................................... 29  VCO Configuration Register .................................................... 44  Chip Identification ..................................................................... 29  VCO Calibration/Bias, CF Calibration, and MSB Calibration Registers ....................................................................................... 45  Serial Port .................................................................................... 29  Applications Information .............................................................. 33  Power Supply ............................................................................... 34  VCO Output Power Control ..................................................... 45  Evaluation Printed Circuit Board (PCB) ..................................... 46  Programmable Performance Technology................................ 34  Changing Evaluation Board Reference Frequency and CP Current Configuration .............................................................. 46  Loop Filter and Frequency Changes ........................................ 34  Evaluation Kit Contents ............................................................ 46  RF Programmable Output Return Loss................................... 35  Outline Dimensions ....................................................................... 47  Mute Mode .................................................................................. 35  Ordering Guide .......................................................................... 48  REVISION HISTORY 11/14—Rev. 0 to Rev. A This Hittite Microwave Products data sheet has been reformatted to meet the styles and standards of Analog Devices, Inc. Updated Format .................................................................. Universal Moved Endnotes from Typical Performance Characteristics Section to the Applications Information Section ....................... 34 Changes to Ordering Guide .......................................................... 48 Rev. A | Page 2 of 48 Data Sheet HMC832 SPECIFICATIONS VPPCP, VDDLS, VCC1, VCC2 = 3.3 V; RVDD, AVDD, DVDD, VCCPD, VCCHF, VCCPS = 3.3 V minimum and maximum specified across the temperature range of −40°C to +85°C. Table 1. Parameter RF OUTPUT CHARACTERISTICS Output Frequency VCO Frequency at PLL Input RF Output Frequency at fVCO OUTPUT POWER RF Output Power at Fundmental Frequency Output Power Control Range HARMONICS FOR FUNDAMENTAL MODE fo Mode at 2 GHz fo/2 Mode at 2 GHz/2 = 1 GHz fo/30 Mode at 3 GHz/30 = 100 MHz fo/62 Mode at 1550 MHz/62 = 25 MHz VCO OUTPUT DIVIDER VCO RF Divider Range PLL RF DIVIDER CHARACTERISTICS 19-Bit N-Divider Range (Integer) 19-Bit N-Divider Range (Fractional) REFERENCE (XREFP PIN) INPUT CHARACTERISTICS Maximum XREFP Input Frequency XREFP Input Level XREFP Input Capacitance 14-Bit R-Divider Range PHASE DETECTOR (PD) 2 PD Frequency Fractional Mode 3 PD Frequency Integer Mode CHARGE PUMP Output Current Charge Pump Gain Step Size PD/Charge Pump SSB Phase Noise 1 kHz 10 kHz 100 kHz LOGIC INPUTS VSW LOGIC OUTPUTS Output High Voltage (VOH ) Output Low Voltage (VOL ) Output Impedance Maximum Load Current POWER SUPPLY VOLTAGES 3.3 V Supplies Test Conditions/Comments Min Typ 25 1500 1500 Max Unit 3000 3000 3000 MHz MHz MHz 2000 MHz across all frequencies (see Figure 25) Maximum gain setting: VCO_REG 0x07[3:0] = 11d single-ended Gain Setting 6: VCO_REG 0x07[3:0] = 6d differential 1 dB steps 7 dBm 2 12 dBm dB 2nd/3rd/4th 2nd/3rd/4th 2nd/3rd/4th 2nd/3rd/4th −20/−29/−45 −26/−10/−34 −33/−10/−40 −40/−6/−43 dBc dBc dBc dBc 1, 2, 4, 6, 8, … 62 1 62 Maximum = 219 − 1 Fractional nominal divide ratio varies (±4) dynamically maximum 16 20 524,287 524,283 AC-coupled 1 −6 MHz dBm pF 1 350 +12 5 16,383 DC DC 100 100 MHz MHz 2.54 20 mA µA −143 −150 −152 dBc/Hz dBc/Hz dBc/Hz 0.02 50 MHz reference, input referred Add 2 dB for fractional mode Add 3 dB for fractional mode 40 50 60 % DVDD 200 1.5 V V Ω mA 3.5 V DVDD 0 100 AVDD, VCCHF, VCCPS, VCCPD, RVDD, DVDD, VPPCP, VDDLS, VCC1, VCC2 Rev. A | Page 3 of 48 3.1 3.3 HMC832 Parameter POWER SUPPLY CURRENTS High Performance Mode 2500 MHz, Gain 11 800 MHz, Gain 11 2500 MHz, Gain 6 800 MHz, Gain 6 2500 MHz, Gain 1 800 MHz, Gain 1 Low Current Mode 2500 MHz, Gain 6 800 MHz, Gain 6 2500 MHz, Gain 1 800 MHz, Gain 1 Power-Down Crystal Off Crystal On, 100 MHz POWER-ON RESET Typical Reset Voltage on DVDD Minimum DVDD Voltage for No Reset Power-On Reset Delay VCO OPEN-LOOP PHASE NOISE fo @ 2 GHz 5 10 kHz Offset 100 kHz Offset 1 MHz Offset 10 MHz Offset 100 MHz Offset fo @ 2 GHz/2 = 1 GHz5 10 kHz Offset 100 kHz Offset 1 MHz Offset 10 MHz Offset 100 MHz Offset fo @ 3 GHz/30 = 100 MHz5 10 kHz Offset 100 kHz Offset 1 MHz Offset 10 MHz Offset 100 MHz Offset FIGURE OF MERIT (FOM) Floor Integer Mode (Figure 24) Floor Fractional Mode (Figure 24) Flicker (Both Modes) (Figure 24) Data Sheet Test Conditions/Comments Min VCO_REG 0x03[1:0] = 3d 4 Gain 11 (VCO_REG 0x07[3:0] = 11d) single-ended output (VCO_REG 0x03[3:2] = 2d) Single-ended output Gain 6 (VCO_REG 0x07[3:0] = 6d) differential output (VCO_REG 0x03[3:2] = 3d) Differential output Gain 1 (VCO_REG 0x07[3:0] = 1d) differential output (VCO_REG 0x03[3:2] = 3d) Differential output VCO_REG 0x03[1:0] = 1d4 Gain 6 (VCO_REG 0x07[3:0] = 6d), differential output (VCO_REG 0x03[3:2] = 3d) Differential output Gain 1 (VCO_REG 0x07[3:0] = 1d), differential output (VCO_REG 0x03[3:2] = 3d) Differential output Register 0x01 = 0, crystal not clocked Register 0x01 = 0, crystal clocked 100 MHz Typ Rev. A | Page 4 of 48 Unit 219 mA 230 226 mA mA 237 210 mA mA 221 mA 195 mA 205 180 mA mA 192 mA 10 5 µA mA 700 250 mV V µs −88 −116 −139 −157 −162 dBc/Hz dBc/Hz dBc/Hz dBc/Hz dBc/Hz −93 −122 −145 −159 −162 dBc/Hz dBc/Hz dBc/Hz dBc/Hz dBc/Hz −110 −139 −160 −163 −163 dBc/Hz dBc/Hz dBc/Hz dBc/Hz dBc/Hz −229 −226 −268 dBc/Hz dBc/Hz dBc/Hz 1.5 Normalized to 1 Hz Normalized to 1 Hz Normalized to 1 Hz Max Data Sheet HMC832 Parameter VCO CHARACTERISTICS VCO Tuning Sensitivity 2800 MHz 2400 MHz 2000 MHz 1600 MHz VCO Supply Pushing Test Conditions/Comments Min Measured with 1.5 V on VTUNE; see Figure 29 Measured with 1.5 V on VTUNE; see Figure 29 Measured with 1.5 V on VTUNE; see Figure 29 Measured with 1.5 V on VTUNE; see Figure 29 Measured with 1.5 V on VTUNE Typ Max 24.6 25.8 25.2 24.3 2.8 Unit MHz/V MHz/V MHz/V MHz/V MHz/V Measured with 100 Ω external termination. See Reference Input Stage section for more details. Slew rate of ≥0.5 ns/V is recommended, see Reference Input Stage section for more details. Frequency is guaranteed across process voltage and temperature from −40°C to +85°C. 3 This maximum PD frequency can only be achieved if the minimum N value is respected. For example, in the case of fractional mode, the maximum PD frequency = fVCO/20 or 100 MHz, whichever is less. 4 For detailed current consumption information, refer to Figure 33 and Figure 36. 5 Gain setting = 6 (VCO_REG 0x07[3:0] = 6d) in high performance mode (VCO_REG 0x03[1:0] = 3d). 1 2 TIMING SPECIFICATIONS SPI Write Timing Characteristics AVDD = DVDD = 3 V, AGND = DGND = 0 V. Table 2. SPI Write Timing Characteristics, See Figure 47 Parameter t1 t2 t3 t4 t5 t6 Test Conditions/Comments SDI setup time to SCLK rising edge SCLK rising edge to SDI hold time SEN low duration SEN high duration SCLK 32nd rising edge to SEN rising edge Recovery time Maximum serial port clock speed Min 3 3 10 10 10 20 Typ Max 50 Unit ns ns ns ns ns ns MHz Table 3. SPI Read Timing Characteristics, See Figure 48 Parameter t1 t2 t3 t4 t5 t6 t7 Test Conditions/Comments SDI setup time to SCK rising edge SCK rising edge to SDI hold time SEN low duration SEN high duration SCK rising edge to SDO time Recovery time SCK 32nd rising edge to SEN rising edge Min 3 3 10 10 Typ 8.2 ns + 0.2 ns/pF 10 10 Rev. A | Page 5 of 48 Max Unit ns ns ns ns ns ns ns HMC832 Data Sheet ABSOLUTE MAXIMUM RATINGS RECOMMENDED OPERATING CONDITIONS Table 4. Absolute Maximum Ratings Parameter AVDD, RVDD, DVDD, VCCPD, VCCHF, VCCPS  VPPCP, VDDLS, VCC1 VCC2 Operating Temperature Storage Temperature Maximum Junction Temperature Thermal Resistance (θJC) (Junction to Case (Ground Paddle)) Reflow Soldering Peak Temperature Time at Peak Temperature ESD Sensitivity (HBM) Rating −0.3 V to +3.6 V −0.3 V to +3.6 V −0.3 V to +3.6 V −40°C to +85°C −65°C to +150°C 150°C 9°C/W Table 5. Recommended Operating Conditions Parameter Temperature Junction Temperature1 Ambient Temperature Supply Voltage AVDD, RVDD, DVDD, VCCPD, VCCHF, VCCPS, VPPCP, VDDLS, VCC1, VCC2 1 260°C 40 sec Class 1B Min Typ −40 3.1 3.3 Max Units 125 +85 °C °C 3.5 V Layout design guidelines set out in Qualification Test Report are strongly recommended. ESD CAUTION Stresses at or above those listed under Absolute Maximum Ratings may cause permanent damage to the product. This is a stress rating only; functional operation of the product at these or any other conditions above those indicated in the operational section of this specification is not implied. Operation beyond the maximum operating conditions for extended periods may affect product reliability. Rev. A | Page 6 of 48 Data Sheet HMC832 40 39 38 37 36 35 34 33 32 31 BIAS VCCPD NC NC VCCPS VCCHF NC LD/SDO SCK SDI PIN CONFIGURATION AND FUNCTION DESCRIPTIONS HMC832 TOP VIEW (Not to Scale) 30 29 28 27 26 25 24 23 22 21 SEN RF_P RF_N VCC1 NC VCC2 NC VTUNE NC NC NOTES 1. NC = NO CONNECT. DO NOT CONNECT TO THIS PIN. 2. THE EXPOSED GROUND PAD MUST BE CONNECTED TO RF/DC GROUND. 12827-002 NC NC NC NC XREFP DVDD CEN NC NC NC 11 12 13 14 15 16 17 18 19 20 AVDD 1 NC 2 VPPCP 3 CP 4 NC 5 NC 6 VDDLS 7 NC 8 NC 9 RVDD 10 Figure 2. Pin Configuration Table 6. Pin Function Descriptions Pin No. 1 2, 5, 6, 8, 9, 11 to 14, 18 to 22, 24, 26, 34, 37, 38 3 4 7 10 15 16 17 Mnemonic AVDD NC Description DC Power Supply for Analog Circuitry. No Connect. These pins are not connected internally; however, it is recommended to connect these pins to RF/dc ground externally. VPPCP CP VDDLS RVDD XREFP DVDD CEN 23 25 27 28 29 30 31 32 33 35 36 39 40 VTUNE VCC2 VCC1 RF_N RF_P SEN SDI SCK LD/SDO VCCHF VCCPS VCCPD BIAS Power Supply for Charge Pump Analog Section. Charge Pump Output. Power Supply for the Charge Pump Digital Section. Reference Supply. Reference Oscillator Input. DC Power Supply for Digital (CMOS) Circuitry. PLL Subsystem Enable. Note that there is no effect on the VCO subsystem. Connect to logic high for normal operation. VCO Varactor. Tuning port input. VCO Analog Supply 2. VCO Analog Supply 1. RF Negative Output. RF Positive Output. PLL Serial Port Enable (CMOS) Logic Input. PLL Serial Port Data (CMOS) Logic Input. PLL Serial Port Clock (CMOS) Logic Input. Lock Detect, or Serial Data, or General-Purpose (CMOS) Logic Output (GPO). DC Power Supply for Analog Circuitry. DC Power Supply for Analog Prescaler. DC Power Supply for Phase Detector. External Bypass Decoupling for Precision Bias Circuits. Note: 1.920 V ± 20 mV reference voltage (BIAS) is generated internally and cannot drive an external load. It must be measured with a 10 GΩ meter, such as the Agilent 34410A; a normal 10 MΩ DVM reads erroneously. Exposed Pad. The exposed pad must be connected to RF/dc ground. EP Rev. A | Page 7 of 48 HMC832 Data Sheet TYPICAL PERFORMANCE CHARACTERISTICS –100 –100 –110 –110 –130 LOOP BW = 127kHz –140 –150 750MHz, EVM = –62.5dB, OR 0.075% 1600MHz, EVM = –57dB OR 0.141% 2500MHz, EVM = –53.3dB OR 0.216% 875MHz, EVM = –64.8dB OR 0.058% 1600MHz, EVM = –59.8dB OR 0.102% 2500MHz, EVM = –55.8dB OR 0.168% –160 –170 1k 10k 100k 1M –120 –140 –150 880MHz, EVM = –61.3dB OR 0.086% 1605MHz, EVM = –57.5dB OR 0.133% 2505MHz, EVM = –52dB OR 0.251% 880MHz, EVM = –61.8dB OR 0.081% 1605MHz, EVM = –57.2dB OR 0.138% 2505MHz, EVM = –53.9dB OR 0.204% –160 10M 100M OFFSET (Hz) Figure 3. Typical Closed-Loop Integer Phase Noise, 50 MHz PD Frequency, Output Gain = 6 (VCO_REG 0x07[3:0] = 6d), High Performance Mode (VCO_REG 0x03[1:0] = 3d), Phase Noise Integrated from 1 kHz to 100 MHz, See Table 12 LOOP BW = 127kHz LOOP BW = 75kHz –130 –170 1k 10k 100k 1M 10M 100M OFFSET (Hz) 12827-006 PHASE NOISE (dBc/Hz) –120 12827-003 PHASE NOISE (dBc/Hz) LOOP BW = 75kHz Figure 6. Typical Closed-Loop Fractional Phase Noise, 50 MHz PD Frequency, Output Gain = 6 (VCO_REG 0x07[3:0] = 6d), High Performance Mode (VCO_REG 0x03[1:0] = 3d), Phase Noise Integrated from 1 kHz to 100 MHz, See Table 12 –100 –60 ÷1 –110 –80 PHASE NOISE (dBc/Hz) –100 LOW CURRENT MODE (VCO_REG0x03[10] = 1d) –140 –160 –180 10k 100k ÷8 –130 ÷16 ÷32 –140 ÷62 –150 –160 HIGH PERFORMANCE MODE (VCO_REG0x03[10] = 3d) 1k ÷4 1M 10M 100M OFFSET (Hz) –170 1k 10k 100k 1M 10M 100M OFFSET (Hz) 12827-007 –120 12827-004 PHASE NOISE (dBc/Hz) ÷2 –120 Figure 7. Closed-Loop Phase Noise at 1800 MHz, Divided by 1 to 62, PD Frequency, Loop Filter Bandwidth = 75 kHz (Type 2 from Table 12), High Performance Mode (VCO_REG 0x03[1:0] = 3d), Subset of Available Output Divide Ratios is Shown; Full Range of Output Divide Values Includes 1, 2, 4, 6, 8, … 58, 60, 62 Figure 4. Open-Loop VCO Phase Noise at 1800 MHz –40 –100 –60 –110 ÷1 ÷2 PHASE NOISE (dBc/Hz) –100 LOW CURRENT MODE (VCO_REG0x03[10] = 1d) –140 HIGH PERFORMANCE MODE (VCO_REG0x03[10] = 3d) –160 –180 1k 10k 100k 1M –120 ÷8 ÷16 –130 ÷32 –140 ÷62 –150 –160 10M OFFSET (Hz) Figure 5. Free Running VCO Phase Noise at 3000 MHz 100M –170 1k 10k 100k 1M OFFSET (Hz) 10M 100M 12827-008 –120 12827-005 PHASE NOISE (dBc/Hz) ÷4 –80 Figure 8. Closed-Loop Phase Noise at 3000 MHz, Divided by 1 to 62, PD Frequency, Loop Filter Bandwidth = 75 kHz (Type 2 from Table 12), High Performance Mode (VCO_REG 0x03[1:0] = 3d), Subset of Available Output Divide Ratios is Shown; Full Range of Output Divide Values Includes 1, 2, 4, 6, 8, … 58, 60, 62 Rev. A | Page 8 of 48 Data Sheet HMC832 –60 –60 –80 –120 –140 –160 HIGH PERFORMANCE MODE (VCO_REG0x03[10] = 3d) SSB INTEGRATED PHASE NOISE = –65.5dBc INTEGRATION BANDWIDTH = 1kHz TO 100MHz SNR = 62.5dB, EVM = 0.075% PHASE NOISE INTEGRATION BANDWIDTH 1kHz TO 100MHz –180 1k 10k 100k 1M 10M 100M Figure 9. Fractional Spurious Performance at 904 MHz, Exact Frequency Mode On, 122.88 MHz XTAL, PFD = 61.44 MHz, Channel Spacing = 200 kHz, Loop Filter Type 2 (See Table 12) HIGH PERFORMANCE MODE (VCO_REG0x03[10] = 3d) SSB INTEGRATED PHASE NOISE = –59dBc INTEGRATION BANDWIDTH = 1kHz TO 100MHz SNR = 56dB, EVM = 0.158%, PHASE NOISE INTEGRATION BANDWIDTH 1kHz TO 100MHz 1k 10k 100k 1M 10M 100M OFFSET (Hz) Figure 12. Fractional Spurious Performance at 1804 MHz, Exact Frequency Mode On, 122.88 MHz XTAL, PFD = 61.44 MHz, Channel Spacing = 200 kHz, Loop Filter Type 2 (See Table 12) –60 PHASE NOISE (dBc/Hz) –80 –100 –120 –140 HIGH PERFORMANCE MODE (VCO_REG0x03[10] = 3d) SSB INTEGRATED PHASE NOISE = –57.45dBc INTEGRATION BANDWIDTH = 1kHz TO 100MHz SNR = 54.45dB, EVM = 0.189%, PHASE NOISE INTEGRATION BANDWIDTH 1kHz TO 100MHz –180 1k 10k 100k 1M –120 –140 HIGH PERFORMANCE MODE (VCO_REG0x03[10] = 3d) SSB INTEGRATED PHASE NOISE = –57.45dBc INTEGRATION BANDWIDTH = 1kHz TO 100MHz SNR = 54.45dB, EVM = 0.189%, PHASE NOISE INTEGRATION BANDWIDTH 1kHz TO 100MHz –160 10M 100M OFFSET (Hz) –180 12827-010 –160 –100 Figure 10. Fractional Spurious Performance at 2118.24 MHz, Exact Frequency Mode On, 122.88 MHz XTAL, PFD = 61.44 MHz, Channel Spacing = 240 kHz, Loop Filter Type 2 (See Table 12) LOW CURRENT MODE (VCO_REG0x03[10] = 1d) SSB INTEGRATED PHASE NOISE = –57dBc INTEGRATION BANDWIDTH = 1kHz TO 100MHz SNR = 54, EVM = 0.199%, PHASE NOISE INTEGRATION BANDWIDTH 1kHz TO 100MHz 1k 10k 100k 1M 10M 100M OFFSET (Hz) 12827-013 LOW CURRENT MODE (VCO_REG0x03[10] = 1d) SSB INTEGRATED PHASE NOISE = –57dBc INTEGRATION BANDWIDTH = 1kHz TO 100MHz SNR = 54dB, EVM = 0.199%, PHASE NOISE INTEGRATION BANDWIDTH 1kHz TO 100MHz –80 Figure 13. Fractional Spurious Performance at 2118.24 MHz, Identical Configuration to Figure 10 with Exact Frequency Mode Off –60 –60 LOW CURRENT MODE (VCO_REG0x03[10] = 1d) SSB INTEGRATED PHASE NOISE = –55.6dBc INTEGRATION BANDWIDTH = 1kHz TO 100MHz SNR = 52.6dB, EVM = 0.234%, PHASE NOISE INTEGRATION BANDWIDTH 1kHz TO 100MHz –80 PHASE NOISE (dBc/Hz) –80 –100 –120 –140 HIGH PERFORMANCE MODE (VCO_REG0x03[10] = 3d) SSB INTEGRATED PHASE NOISE = –56dBc INTEGRATION BANDWIDTH = 1kHz TO 100MHz SNR = 53dB, EVM = 0.224%, PHASE NOISE INTEGRATION BANDWIDTH 1kHz TO 100MHz 100k 1M OFFSET (Hz) 10M 100M –120 –140 HIGH PERFORMANCE MODE (VCO_REG0x03[10] = 3d) SSB INTEGRATED PHASE NOISE = –56dBc INTEGRATION BANDWIDTH = 1kHz TO 100MHz SNR = 53dB, EVM = 0.224%, PHASE NOISE INTEGRATION BANDWIDTH 1kHz TO 100MHz –180 12827-011 10k –100 –160 –180 1k LOW CURRENT MODE (VCO_REG0x03[10] = 1d) SSB INTEGRATED PHASE NOISE = –55.6dBc INTEGRATION BANDWIDTH = 1kHz TO 100MHz SNR = 52.6dB, EVM = 0.234%, PHASE NOISE INTEGRATION BANDWIDTH 1kHz TO 100MHz Figure 11. Fractional Spurious Performance at 2646.96 MHz, Exact Frequency Mode On, 122.88 MHz XTAL, PFD = 61.44 MHz, Channel Spacing = 240 kHz, Loop Filter Type 2 (See Table 12) 1k 10k 100k 1M OFFSET (Hz) 10M 100M 12827-014 PHASE NOISE (dBc/Hz) –140 –180 –60 PHASE NOISE (dBc/Hz) –120 –160 OFFSET (Hz) –160 –100 LOW CURRENT MODE (VCO_REG0x03 [10] = 1d) SSB INTEGRATED PHASE NOISE = –58.7dBc INTEGRATION BANDWIDTH = 1kHz TO 100MHz SNR = 55.7dB, EVM = 0.164%, PHASE NOISE INTEGRATION BANDWIDTH 1kHz TO 100MHz 12827-012 –100 PHASE NOISE (dBc/Hz) LOW CURRENT MODE (VCO_REG0x03[10] = 1d) SSB INTEGRATED PHASE NOISE = –64.3dBc INTEGRATION BANDWIDTH = 1kHz TO 100MHz SNR = 61.3dB, EVM = 0.086%, PHASE NOISE INTEGRATION BANDWIDTH 1kHz TO 100MHz 12827-009 PHASE NOISE (dBc/Hz) –80 Figure 14. Fractional Spurious Performance at 2646.96 MHz, Identical Configuration to Figure 11 with Exact Frequency Mode Off Rev. A | Page 9 of 48 HMC832 Data Sheet –60 –120 –80 –140 PHASE NOISE (dBc/Hz) PHASE NOISE (dBc/Hz) –130 100MHz OUTPUT 55.55MHz OUTPUT –150 –160 –100 –120 –140 –160 1k 10k 100k 1M 10M 100M OFFSET (Hz) –180 12827-015 –170 100 Figure 15. Low Frequency Performance, 100 MHz XTAL, PD Frequency = 50 MHz, Loop Filter Type 3 (See Table 12), Integer Mode, 50 MHz Low-Pass Filter at the Output of HMC832 for the 25 MHz Curve Only, Charge Pump Set to Maximum Value 1k 10k 100k 1M 10M 100M OFFSET (Hz) 12827-018 25MHz OUTPUT Figure 18. Typical Spurious Emissions at 2000.1 MHz, 50 MHz Fixed Reference, 50 MHz PD Frequency, Integer Boundary Spur Inside the Loop Filter Bandwidth (See the Loop Filter and Frequency Changes Section) –60 –60 TYPICAL SPURIOUS VS. OFFSET FROM 2GHz, FIXED REFERENCE = 50MHz –70 PHASE NOISE (dBc/Hz) –100 –120 –140 –90 –100 TYPICAL SPURIOUS VS. OFFSET FROM 2GHz, TUNABLE REFERENCE ~47.5MHz –110 –160 1k 10k 100k 1M 10M 100M OFFSET (Hz) Figure 16. Typical Spurious Emissions at 2000.1 MHz, Tunable Reference, Loop Filter Type 2 (see Table 12 and the Loop Filter and Frequency Changes Section) –40 –120 2000.01 12827-016 –180 –80 2000.1 2001 OUTPUT FREQUENCY (kHz) 12827-019 PHASE NOISE (dBc/Hz) –80 Figure 19. Typical Spurious vs. Offset from 2 GHz, Fixed 50 MHz Reference vs. Tunable 47.5 MHz Reference (See the Loop Filter and Frequency Changes Section) –100 HIGH PERFORMANCE MODE ON (VCO_REG0x03[1:0] = 3d) –110 –60 –40°C +27°C +85°C 100kHz OFFSET ALL MODES PHASE NOISE (dBc/Hz) –100 –120 –140 2854MHz 2453MHz 2013MHz 1587MHz 10k –130 100MHz OFFSET LOW CURRENT MODE 100MHz OFFSET HIGH PERFORMANCE MODE –140 –150 –160 –180 1k –120 100k 1M 10M OFFSET (Hz) Figure 17. Open-Loop Phase Noise 100M –170 30 100 300 FREQUENCY (MHz) 1000 3000 12827-020 –160 12827-017 PHASE NOISE (dBc/Hz) 1MHz OFFSET ALL MODES –80 Figure 20. Open-Loop Phase Noise vs. Frequency at Various Temperatures Rev. A | Page 10 of 48 Data Sheet EVM (%) –65 0.0447 –70 –75 0.0141 –80 –85 PHASE NOISE INTEGRATED FROM 10kHz TO 20MHz –90 100 1000 0.0045 OUTPUT FREQUENCY (MHz) –210 TYP FOM VS OFFSET –220 FOM FLOOR FOM 1/f NOISE –230 –240 100 1k 10k 100k 1M OFFSET (Hz) Figure 21. Single Sideband Integrated Phase Noise, High Performance Mode, Loop Filter Type 2 (See Table 12) 12827-024 0.1410 –60 NORMALIZED PHASE NOISE (dBc/Hz) –55 –200 0.4460 –40°C +27°C +85°C 12827-021 SSB INTEGRATED PHASE NOISE (dBc) –50 HMC832 Figure 24. Figure of Merit 20 15 RETURN LOSS (VCO_REG0x03[5] = 0) RETURN LOSS (VCO_REG0x03[5] = 1) 15 10 OUTPUT POWER (dBm) 5 0 –5 LOW CURRENT MODE (VCO_REG0x03[1:0] = 1d) GAIN SETTING = 11 (VCO_REG0x07[3:0] = 11d) 5 GAIN SETTING = 5 (VCO_REG0x07[3:0] = 5d) 0 GAIN SETTING = 0 (VCO_REG0x07[3:0] = 0d) –5 –10 –10 –15 HIGH PERFORMANCE MODE LOW CURRENT MODE PHASE NOISE INTEGRATED FROM 10kHz TO 20MHz 25 100 1000 3000 FREQUENCY (MHz) Figure 22. Typical Single-Ended Output Power vs. Frequency (Mid Gain Setting 6) 10 –20 12827-022 –15 10 25 1000 3000 FREQUENCY (MHz) Figure 25. Typical Output Power vs. Frequency and Gain (Single-Ended) 0 –40°C +27°C +85°C 8 100 12827-025 OUTPUT POWER (dBm) HIGH PERFORMANCE MODE (VCO_REG0x03[1:0] = 3d) RETURN LOSS 0 (VCO_REG0x03[5] = 0) 6 RETURN LOSS 1 (VCO_REG0x03[5] = 1) RETURN LOSS (dB) OUTPUT POWER (dBm) –5 4 2 0 –10 –15 –20 –2 0 2 4 6 GAIN SETTING 8 10 –30 12827-023 –6 25 100 1000 OUTPUT FREQUENCY (MHz) Figure 23. Typical RF Output Power at 2 GHz (Single-Ended) vs. Temperature Rev. A | Page 11 of 48 Figure 26. RF Output Return Loss 8000 12827-026 –25 –4 HMC832 Data Sheet 3.2 200 SETTLING TIME TO < 10 DEGREES PHASE ERROR SETTLING TIME TO < 10 DEGREES PHASE ERROR 150 PHASE ERROR (Degrees) FREQUENCY (GHz) 3.0 2.8 2.6 100 50 0 –50 –100 2.4 0 20 40 60 80 100 120 140 160 TIME (µs) –200 12827-027 2.2 Figure 27. Frequency Settling After Frequency Change, Autocalibration Enabled, Loop Filter BW = 127 kHz (Type 1, See Table 12) 0 20 80 100 140 160 200 PHASE ERROR (Degrees) SETTLING TIME TO < 10 DEGREES PHASE ERROR 2.505 2.500 NOTE: LOOP FILTER BANDWIDTH = 127kHz, LOOP FILTER PHASE MARGIN = 61 DEGREES. THIS RESULT IS DIRECTLY AFFECTED BY LOOP FILTER DESIGN. FASTER SETTLING TIME IS POSSIBLE WITH WIDER LOOP FILTER BANDWIDTH AND LOWER PHASE MARGIN. 40 60 80 100 120 140 160 0 –50 –100 NOTE: LOOP FILTER BANDWIDTH = 127kHz, LOOP FILTER PHASE MARGIN = 61 DEGREES. THIS RESULT IS DIRECTLY AFFECTED B Y LOOP FILTER DESIGN. FASTER SETTLING TIME IS POSSIBLE WITH WIDER LOOP FILTER BANDWIDTH AND LOWER PHASE MARGIN. TIME (µs) –200 12827-028 20 50 –150 2.495 0 100 Figure 28. Frequency Settling After Frequency Change, Manual Calibration, Loop Filter BW = 127 kHz (Type 1 in Table 12) 0 20 40 60 80 100 120 140 12827-031 SETTLING TIME TO < 10 DEGREES PHASE ERROR 160 TIME (µs) Figure 31. Phase Settling After Frequency Change, Manual Calibration 4.0 80 TUNE VOLTAGE AFTER CALIBRATION (V) 2854MHz 2453MHz 2013MHz 1587MHz TUNING CAP 15 70 60 50 40 30 20 3.5 CALIBRATED AT +85°C, MEASURED AT +85°C CALIBRATED AT +85°C, MEASURED AT –40°C CALIBRATED AT –40°C, MEASURED AT –40°C CALIBRATED AT –40°C, MEASURED AT +85°C CALIBRATED AT +27°C, MEASURED AT +27°C 3.0 2.5 2.0 1.5 1.0 0.5 fMIN 0.66 1.30 2.00 2.60 TUNING VOLTAGE (V) Figure 29. Typical VCO Sensitivity 3.30 12827-029 0 fMAX 0 1330 1520 1710 1900 2090 2280 2470 2660 2850 3040 VCO FREQUENCY (MHz) 12827-032 90 10 120 Figure 30. Phase Settling After Frequency Change, Autocalibration Enabled, Loop Filter BW = 127 kHz (Type 1, See Table 12) 150 FREQUENCY (GHz) 60 TIME (µs) 2.510 kVCO (MHz/V) 40 12827-030 –150 Figure 32. Typical Tuning Voltage After Calibration (See the Loop Filter and Frequency Changes Section) Rev. A | Page 12 of 48 Data Sheet OUTPUT GAIN 0dB OUTPUT GAIN 6dB fO/4 230 fO/62 fO/2 220 fO 210 HIGH PERFORMANCE MODE (VCO_REG0x03[1:0] = 3d) 200 190 LOW CURRENT CONSUMPTION MODE (VCO_REG0x03[1:0] = 1d) 180 OUTPUT GAIN 0dB OUTPUT GAIN 6dB fO/4 170 fO/2 240 fO 220 HIGH PERFORMANCE MODE (VCO_REG0x03[1:0] = 3d) 200 LOW CURRENT CONSUMPTION MODE (VCO_REG0x03[1:0] = 1d) 0 500 1000 1500 2000 2500 3000 OUTPUT FREQUENCY (MHz) 12827-033 180 160 Figure 33. Current Consumption in Single-Ended Output Configuration, Output Gain Configured in VCO_REG 0x07[3:0], Differential or Single-Ended Mode Programmed in VCO_REG 0x03[3:2] 0 500 1500 1000 2000 2500 3000 OUTPUT FREQUENCY (MHz) 12827-036 CURRENT CONSUMPTION (mA) 260 fO/62 CURRENT CONSUMPTION (mA) 240 HMC832 Figure 36. Current Consumption in Differential Output Configuration, Output Gain Configured in VCO_REG 0x07[3:0], Differential or Single-Ended Mode Programmed in VCO_REG 0x03[3:2] 235 232 230 230 14MHz SINUSOIDAL 25MHz SINUSOIDAL 50MHz SQUARE 100MHz SQUARE 225 FOM (dBc/Hz) FOM (dBc/Hz) 228 226 220 215 224 210 –12 –9 –6 –3 0 205 3 REFERENCE POWER (dBm) Figure 34. Reference Input Sensitivity, Square Wave, Measured from a 50 Ω Source with a 100 Ω External Resistor Termination –10 ISOLATION (dB) –30 200 –20 12827-034 220 –15 14MHz SQUARE WAVE 25MHz SQUARE WAVE 50MHz SQUARE WAVE 100MHz SQUARE WAVE –90 1000 FRQUENCY (MHz) 3000 12827-035 MUTE ON (VCO_REG0x03[8:7] = 3d) –110 100 –5 0 5 Figure 37. Reference Input Sensitivity, Sinusoidal Wave, Measured from a 50 Ω Source with a 100 Ω External Resistor Termination BOTH RF_N AND RF_P PINS OFF, (VCO_REG0x03[3:2] = 0d), MUTE OFF (ON ONLY DURING VCO CALIBRATION VCO_REG0x03[8:7] = 1d) –70 –10 REFERENCE POWER (dBm) SIGNAL ON RF_N PIN WHEN RF_N PIN OFF, RF_P PIN ON (VCO_REG0x03[3:2] = 1d), MUTE OFF (ON ONLY DURING VCO CALIBRATION VCO_REG0x03[8:7] = 1d) –50 –15 12827-038 222 Figure 35. Mute Mode Isolation, Measured at Output Rev. A | Page 13 of 48 HMC832 Data Sheet THEORY OF OPERATION SEN SDI 4 REF BUFF CONTROL RF BUFFER EN SCK LD_SDO 3 PHASE FREQUENCY DETECTOP CAL VSPI N DIVIDER R DIVIDER XREFP CAL RF_N RF_P CNTRL fO OR ÷N OR ×2 VCO EN PLL BUFF VTUNE PLL ONLY 12827-043 CEN MODULATOR PLL BUFF EN CP CHARGE PUMP VSPI Figure 38. PLL and VCO Subsystems The HMC832 PLL with integrated VCO is comprised of two subsystems; PLL subsystem and VCO subsystem, as shown in Figure 38. PLL SUBSYSTEM OVERVIEW The PLL subsystem divides down the VCO output to the desired comparison frequency via the N-divider (integer value set in Register 0x03, fractional value set in Register 0x04), compares the divided VCO signal to the divided reference signal (reference divider set in Register 0x02) in the phase detector (PD), and drives the VCO tuning voltage via the charge pump (CP) (configured in Register 0x09) to the VCO subsystem. Some of the additional PLL subsystem functions include • • • • Delta-sigma configuration (Register 0x06). Exact frequency mode (configured in Register 0x0C, Register 0x03, and Register 0x04). Lock detect (LD) configuration (use Register 0x07 to configure LD and Register 0x0F to configure the LD_SDO output pin). External CEN pin used for the hardware PLL enable pin. CEN pin does not affect the VCO subsystem. Typically, only writes to the divider registers (integer part uses Register 0x03, fractional part uses Register 0x04) of the PLL subsystem are required for HMC832 output frequency changes. Divider registers of the PLL subsystem (Register 0x03 and Register 0x04), set the fundamental frequency (1500 MHz to 3000 MHz) of the VCO subsystem. Output frequencies ranging from 25 MHz to 1500 MHz are generated by tuning to the appropriate fundamental VCO frequency (1500 MHz to 3000 MHz) by programming the N divider (Register 0x03 and Register 0x04) and programming the output divider (divide by 1/2/4/6 … /60/62, in VCO_REG 0x02) in the VCO subsystem. For detailed frequency tuning information and example, see the Frequency Tuning section. VCO SUBSYSTEM OVERVIEW The VCO subsystem consists of a capacitor switched step tuned VCO and an output stage. In typical operation, the VCO subsystem is programmed with the appropriate capacitor switch setting that is executed automatically by the PLL subsystem autocalibration state machine when autocalibration is enabled (Register 0x0A[11] = 0, see the VCO Calibration section for more information). The VCO tunes to the fundamental frequency (1500 MHz to 3000 MHz), and is locked by the CP output from the PLL subsystem. The VCO subsystem controls the output stage of the HMC832 enabling configuration of • User defined performance settings (see the Programmable Performance Technology section) that are configured via VCO_REG 0x03[1:0]. • VCO output divider settings that are configured in the VCO_REG 0x02 (divide by 2/4/6 … 60/62 to generate frequencies from 25 MHz to 1500 MHz, or divide by 1 to generate fundamental frequencies between 1500 MHz and 3000 MHz). • Output gain settings (VCO_REG 0x07[3:0]). • Output return loss setting (VCO_REG 0x03[5]). See Figure 26 for more information. • Single-ended or differential output operation (VCO_REG 0x03[3:2]). • Mute (VCO_REG 0x03[8:7]). SPI (SERIAL PORT INTERFACE) CONFIGURATION OF PLL AND VCO SUBSYSTEMS The two subsystems (PLL subsystem and VCO subsystem) have their own register maps as shown in the PLL Register Map and VCO Subsystem Register Map sections. Typically, writes to both register maps are required for initialization and frequency tuning operations. As shown in Figure 38, the PLL subsystem is connected directly to the SPI of the HMC832, whereas the VCO subsystem is connected indirectly through the PLL subsystem to the Rev. A | Page 14 of 48 Data Sheet HMC832 HMC832 SPI. As a result, writes to the PLL Register Map are written directly and immediately, whereas the writes to the VCO Subsystem Register Map are written to the PLL subsystem Register 0x05 and forwarded via the internal VCO SPI (VSPI) to the VCO subsystem. This is a form of indirect addressing. Note that VCO subsystem registers are write only and cannot be read. More information is available in the VCO Serial Port Interface (VSPI) section. VCO Serial Port Interface (VSPI) The HMC832 communicates with the internal VCO subsystem via an internal 16-bit VCO SPI. The internal serial port controls the step tuned VCO and other VCO subsystem functions. Note that the internal VCO subsystem SPI (VSPI) runs at the rate of the autocalibration FSM clock, tFSM, (see the VCO Autocalibration section) where the FSM clock frequency cannot be greater than 50 MHz. The VSPI clock rate is set by Register 0x0A[14:13]. Writes to the control registers of the VCO are handled indirectly via writes to Register 0x05 of the HMC832. A write to HMC832 Register 0x05 causes the internal PLL subsystem to forward the packet, MSB first, across its internal serial link to the VCO subsystem, where it is interpreted. VSPI Use of Register 0x05 The packet data written into Register 0x05 is subparsed by logic at the VCO subsystem into the following three fields: Field 1—Bits[2:0]: 3-bit VCO_ID, target subsystem address = 000b. Field 2—Bits[6:3]: 4-bit VCO_REGADDR, the internal register address inside the VCO subsystem. they are not zero (Register 0x05[6:0] ≠ 0), autocalibration does not function. To ensure that the autocalibration functions, it is critical to write Register 0x05[6:0] = 0 after the last VCO subsystem write prior to an output frequency change triggered by a write to either Register 0x03 or Register 0x04. However, it is impossible to write only Register 0x05[6:0] = 0 (VCO_REGADDR) without writing Register 0x05[15:7] (VCO_DATA). Therefore, to ensure that the VCO_DATA (Register 0x05[15:7]) in VCO_REGADDR 0x00 is not changed, it is required to read the switch settings provided in Register 0x10[7:0], and then rewrite them to Register 0x05[15:7], as shown in the following example: 1. Read Register 0x10 2. Write to Register 0x05 the following: a. Register 0x05[15:14] = Register 0x10[7:6] b. Register 0x05[13] = 1, reserved bit c. Register 0x05[12:8] = Register 0x10[4:0] d. Register 0x05[7:0] = 0 Changing the VCO subsystem configuration (VCO Subsystem Register Map section) without following this procedure results in a failure to lock to the desired frequency. For applications not using the read functionality of the HMC832 SPI, in which Register 0x10 cannot be read, it is possible to write Register 0x05 = 0x0 to set Register 0x05[6:0] = 0, which also sets the VCO subband setting equal to zero (Register 0x05[15:7] = 0), effectively programming incorrect VCO subband settings and causing the HMC832 to lose lock. This procedure is then immediately followed by a write to: Field 3—Bits[15:7]: 9-bit VCO_DATA, data field to write to the VCO register.   For example, to write 0_1111_1110 into Register 2 of the VCO subsystem (VCO_ID = 000b), and set the VCO output divider to divide by 62, the following needs to be written to Register 0x05 = 0_1111_1110b, 0010b, 000b or equivalently, Register 0x05 = 7F10. This write effectively retriggers the autocalibration state machine, forcing the HMC832 to relock whether in integer or fractional mode. During autocalibration, the autocalibration controller writes into the VCO register address specified by the VCO_ID and VCO_REGADDR, as stored in Register 0x05[2:0] and Register 0x05[6:3], respectively. Autocalibration requires that these values be zero (Register 0x05[6:0] = 0); otherwise, when Register 0x03, if in integer mode. Register 0x04, if in fractional mode. This procedure causes the HMC832 to lose lock and relock after every VCO subsystem change. Typical output frequency and lock time is shown in Figure 27 and Figure 30, and is typically in the order of 100 μs for a phase settling of 10°, and is also dependent on loop filter design (loop filter bandwidth and loop filter phase margin). Rev. A | Page 15 of 48 HMC832 Data Sheet VCO SUBSYSTEM SPI LD_SDO VSPI VCO SUBSYSTEM VCO_REG0x03[1:0] PERFORMANCE TUNING VCO_REG0x01[0] MASTER ENABLE VCO SUBSYSTEM VDD VCO_REG0x01[5] EN VCO CONTROL VCO_REG0x03[3] RF_P ÷1, ÷2, ÷4, ÷6, ... ÷62 VCO_REG0x01[3] EN RF_N VCO_REG0x02[5:0] CONTROL VCO_REG0x03[2] CAL VCO_REG0x07[3:0] VCO_REG0x01[2] EN MODULATOR VCO VTUNE N DIVIDER XREFP R DIVIDER PHASE FREQUENCY DETECTOR VCO CAL VOLTAGE CHARGE PUMP VCO_REG0x00[0] CP LOOP FILTER 12827-044 VCO_REG0x01[1], EN VCO_REG0x00[8:1] Figure 39. PLL and VCO Subsystems feature is implemented in the internal state machine. It manages the selection of the VCO subband (capacitor selection) when a new frequency is programmed. The VCO switches may also be controlled directly via Register 0x05 for testing or for other special purpose operations. Other control bits specific to the VCO are also sent via Register 0x05. The HMC832 contains a VCO subsystem that can be configured to operate in: • Fundamental frequency (fo) mode (1500 MHz to 3000 MHz). • Divide by N mode, where N = 2, 4, 6, 8 … 58, 60, 62 (25 MHz to 1500 MHz). All modes are VCO register programmable, as shown in Figure 39. One loop filter design can be used for the entire frequency of operation of the HMC832. VCO Calibration VCO Autocalibration The HMC832 uses a step tuned type VCO. A simplified step tuned VCO is shown in Figure 41. A step tuned VCO is a VCO with a digitally selectable capacitor bank allowing the nominal center frequency of the VCO to be adjusted or stepped by switching in and out of the VCO tank capacitors. Note that more than one capacitor can be switched in at a time. A step tuned VCO allows the user to center the VCO on the required output frequency while keeping the varactor tuning voltage optimized near the mid voltage tuning point of the HMC832 charge pump. This enables the PLL charge pump to tune the VCO over the full range of operation with both a low tuning voltage and a low tuning sensitivity (kVCO). To use a step tuned VCO in a closed loop, the VCO must be calibrated such that the HMC832 knows which switch position on the VCO is optimum for the desired output frequency. The HMC832 supports autocalibration of the step tuned VCO. The autocalibration fixes the VCO tuning voltage at the optimum midpoint of the charge pump output, then measures the free running VCO frequency while searching for the setting which results in the free running output frequency that is closest to the desired phase-locked frequency. This procedure results in a phase-locked oscillator that locks over a narrow voltage range on the varactor. A typical tuning curve for a step tuned VCO is shown in Figure 40. Note that the tuning voltage stays in a narrow range over a wide range of output frequencies. The VCO switches are normally controlled automatically by the HMC832 using the autocalibration feature. The autocalibration Rev. A | Page 16 of 48 Data Sheet HMC832 switch settings vs. time and temperature. The user does not normally need to be concerned about which switch setting is used for a given frequency because this is handled by the autocalibration routine. CALIBRATED AT +85°C, MEASURED AT +85°C CALIBRATED AT +85°C, MEASURED AT –40°C CALIBRATED AT –40°C, MEASURED AT –40°C CALIBRATED AT –40°C, MEASURED AT +85°C CALIBRATED AT +27°C, MEASURED AT +27°C 3.5 3.0 The accuracy required in the calibration affects the amount of time required to tune the VCO. The calibration routine searches for the best step setting that locks the VCO at the current programmed frequency and ensures that the VCO stays locked and performs well over its full temperature range without additional calibration, regardless of the temperature at which the VCO was calibrated. 2.5 2.0 1.5 1.0 0.5 fMAX fMIN 0 1330 1520 1710 1900 2090 2280 2470 2660 2850 3040 VCO FREQUENCY (MHz) Autocalibration can also be disabled, thereby allowing manual VCO tuning. Refer to the Manual VCO Calibration for Fast Frequency Hopping section for a description of manual tuning. 12827-046 TUNE VOLTAGE AFTER CALIBRATION (V) 4.0 Figure 40. Typical VCO Tuning Voltage After Calibration The calibration is normally run automatically, once for every change of frequency. This ensures optimum selection of VCO SCK VSCK SDI VSDO HOST DTUNE VCO SUB-BAND SELECT VCO VSPI VSLE SEN SYNTHESIZER CP LOOP FILTER VTUNE VCOIP VCO Figure 41. Simplified Step Tuned VCO Rev. A | Page 17 of 48 12827-045 RFOUT HMC832 Data Sheet Autocalibration Using Register 0x05 N is the ratio of the target VCO frequency, fVCO, to the frequency of the PD, fPD, where N can be any rational number supported by the N divider. Autocalibration transfers switch control data to the VCO subsystem via Register 0x05. The address of the VCO subsystem in Register 0x05 is not altered by the autocalibration routine. The address and ID of the VCO subsystem in Register 0x05 must be set to the correct value before autocalibration is executed. For more information see the VCO Serial Port Interface (VSPI) section. N is set by the integer (NINT = Register 0x03) and fractional (NFRAC = Register 0x04) register contents by Equation 2. N = NINT + NFRAC/224 The autocalibration state machine and the data transfers to the internal VCO subsystem SPI (VSPI) run at the rate of the FSM clock, tFSM, where the FSM clock frequency cannot be greater than 50 MHz. Automatic Relock on Lock Detect Failure It is possible by setting Register 0x07[13] to have the VCO subsystem automatically rerun the calibration routine and relock itself if lock detect indicates an unlocked condition for any reason. With this option the system attempts to relock only once. tFSM = tXTAL × 2m (3) where m is 0, 2, 4, or 5 as determined by Register 0x0A[14:13]. The expected number of VCO counts, V, is given by V = floor (N × 2n) VCO Autocalibration on Frequency Change fVCOM = V × fXTAL/(2n × R) fERR ≈ ±fPD/2n + 1 (6) A 5-bit step tuned VCO, for example, nominally requires five measurements for calibration or in the worst case, six measurements, and hence, seven VSPI data transfers of 20 clock cycles each. The measurement has a programmable number of wait states, k, of 128 FSM cycles defined by Register 0x0A[7:6] = k. Total calibration time, worst case, is given by The VCO frequency is counted for tMMT, the period of a single autocalibration measurement cycle. (1) where: n is set by Register 0x0A[2:0] and results in measurement periods which are multiples of the PD period, tXTALR. R is the reference path division ratio currently in use, Register 0x02. tXTAL is the period of the external reference (crystal) oscillator. tCAL = k128 tFSM + 6tPD 2n + 7 × 20 tFSM tCAL = tXTAL (6R × 2n + (140+(k × 128)) × 2m) tPD CALIBRATION WINDOW tMMT = RTXTAL × 2n ÷ 2n ÷R START STOP REGA[2:0] n = [0, 1, 2, 3, 5, 6, 7, 8] CTR VCO V 12827-047 50MHz MAX FOR FSM + VSPI CLOCKS (8) For guaranteed hold of lock, across temperature extremes, the resolution should be better than 1/8th the frequency step caused by a VCO subband switch change. Better resolution settings show no improvement. REG0x02 ÷ 2m (7) or equivalently The VCO autocalibration counter, on average, expects to register N counts, rounded down (floor) to the nearest integer, for every PD cycle. REGA[14:13] m = [0, 2, 4, 5] (5) where the worst case measurement error, fERR , is VCO Autocalibration Time and Accuracy tMMT = tXTAL × R × 2n (4) The nominal VCO frequency measured, fVCOM, is given by Assuming Register 0x0A[11] = 0, the VCO calibration starts automatically whenever a frequency change is requested. If it is desired to rerun the autocalibration routine for any reason at the same frequency, rewrite the frequency change with the same value and the autocalibration routine executes again without changing the final frequency. XREF (2) FSM Figure 42. VCO Calibration Table 7. Autocalibration Example with fXTAL = 50 MHz, R = 1, m = 0 Control Value Register 0x0A[2:0] 0 1 2 3 4 n 0 1 2 3 5 2n 1 2 4 8 32 tMMT (µs) 0.02 0.04 0.08 0.16 0.64 Rev. A | Page 18 of 48 tCAL (µs) 4.92 5.04 5.28 5.76 8.64 fERR Maximum ±25 MHz ±12.5 MHz ±6.25 MHz ±3.125 MHz ±781 kHz Data Sheet Control Value Register 0x0A[2:0] 5 6 7 HMC832 n 6 7 8 VCO Autocalibration Example The VCO subsystem must satisfy the maximum fPD limited by the two following conditions: N ≥ 16 (fINT), N ≥ 20.0 (fFRAC) where N = fVCO/ fPD. fPD ≤ 100 MHz For example, if the VCO subsystem output frequency is to operate at 2.01 GHz and the crystal frequency is fXTAL = 50 MHz, R = 1, and m = 0 (see Figure 42), then tFSM = 20 ns (50 MHz). Note that when using autocalibration, the maximum autocalibration finite state machine (FSM) clock cannot exceed 50 MHz (see Register 0x0A[14:13]). The FSM clock does not affect the accuracy of the measurement, it only affects the time to produce the result. This same clock is used to clock the 16-bit VCO serial port. If time to change frequencies is not a concern, then the calibration time for maximum accuracy can be set, and therefore, the measurement resolution is of no concern. 2n 64 128 256 tMMT (µs) 1.28 2.56 5.12 Across all VCOs, a measurement resolution better than 800 kHz produces correct results. Setting m = 0 and n = 5, provides 781 kHz of resolution and adds 8.6 μs of autocalibration time to a normal frequency hop. After the autocalibration sets the final switch value, 8.64 μs after the frequency change command, the fractional register is loaded, and the loop locks with a normal transient predicted by the loop dynamics. Therefore, as shown in this example, autocalibration typically adds about 8.6 μs to the normal time to achieve frequency lock. Use autocalibration for all but the most extreme frequency hopping requirements. Manual VCO Calibration for Fast Frequency Hopping When switching frequencies quickly is needed, it is possible to eliminate the autocalibration time by calibrating the VCO in advance and storing the switch number vs. frequency information in the host. This is accomplished by initially locking the HMC832 on each desired frequency using autocalibration, then reading and storing the selected VCO switch settings. The VCO switch settings are available in Register 0x10[7:0] after every autocalibration operation. The host must then program the VCO switch settings directly when changing frequencies. fERR Maximum ±390 kHz ± 95 kHz ±98 kHz Manual writes to the VCO switches are executed immediately as are writes to the integer and fractional registers when autocalibration is disabled. Therefore, frequency changes with manual control and autocalibration disabled requires a minimum of two serial port transfers to the PLL, once to set the VCO switches and once to set the PLL frequency. When autocalibration is disabled, Register 0x0A[11] = 1, the VCO updates its registers immediately with the value written via Register 0x05. The VCO internal transfer requires 16 VSCK clock cycles after the completion of a write to Register 0x05. VSCK and the autocalibration controller clock are equal to the input reference divided by 0, 4, 16, or 32 as controlled by Register 0x0A[14:13]. Registers Required for Frequency Changes in Fractional Mode In fractional mode (Register 0x06[11] = 1), a large change of frequency may require main serial port writes to one of the three following registers • Using an input crystal of 50 MHz (R = 1 and fPD = 50 MHz) the times and accuracies for calibration using Equation 6 and Equation 8 are listed in Table 7, where minimal tuning time is 1/8th of the VCO band spacing. tCAL (µs) 12.48 20.16 35.52 • • The integer register, INTG, Register 0x03. This is required only if the integer part changes. The VCO SPI register, Register 0x05. This is required only for manual control of VCO if Register 0x0A[11] = 1, autocalibration is disabled, or to change the VCO output divider value (VCO_REG 0x02), see Figure 39 for more information. The fractional register, Register 0x04. The fractional register write triggers autocalibration when Register 0x0A[11] = 0, and it is loaded into the modulator automatically after the autocalibration runs. If autocalibration is disabled, Register 0x0A[11] = 1, the fractional frequency change is loaded immediately into the modulator when the register is written with no adjustment to the VCO. Small steps in frequency in fractional mode, with autocalibration enabled (Register 0x0A[11] = 0), usually require only a single write to the fractional register. In a worst-case scenario, three main serial port transfers to the HMC832 could be required to change frequencies in fractional mode. If the frequency step is small and the integer part of the frequency does not change, then the integer register is not changed. In all cases, in fractional mode, it is necessary to write to the fractional register, Register 0x04, for frequency changes. Rev. A | Page 19 of 48 HMC832 Data Sheet Registers Required for Frequency Changes in Integer Mode VCO Built-In Test (BIST) with Autocalibration In integer mode (Register 0x06[11] = 0), a change of frequency requires main serial port writes to the following registers: • • VCO SPI register, Register 0x05. This is required for manual control only of the VCO when Register 0x0A[11] = 1 (autocalibration disabled) or when the VCO output divider value must change (VCO_REG 0x02). Integer register, Register 0x03. In integer mode, an integer register write triggers autocalibration when Register 0x0A[11] = 0 and it is loaded into the prescaler automatically after autocalibration runs. If autocalibration is disabled, Register 0x0A[11] = 1, the integer frequency change is loaded into the prescaler immediately when written with no adjustment to the VCO. Normally, changes to the integer register cause large steps in the VCO frequency; therefore, the VCO switch settings must be adjusted. Autocalibration enabled is the recommended method for integer mode frequency changes. If autocalibration is disabled (Register 0x0A[11] = 1), a priori knowledge of the correct VCO switch setting and the corresponding adjustment to the VCO is required before executing the integer frequency change. VCO Output Mute Function The HMC832 features an intelligent output mute function with the capability to disable the VCO output while maintaining fully functional PLL and VCO subsystems. The mute function is automatically controlled by the HMC832 and provides a number of mute control options including • • Automatic mute. This option automatically mutes the outputs during VCO calibration during output frequency changes. This mode can be useful in eliminating any out of band emissions during frequency changes, and ensuring that the system emits only the desired frequencies. It is enabled by writing VCO_REG 0x03[8:7] = 1d. Always mute (VCO_REG 0x03[8:7] = 3d). This mode is used for manual mute control. Typical isolation when the HMC832 is muted is always better than 50 dB, and is ~40 dB better than disabling the individual outputs of the HMC832 via VCO_REG 0x03[3:2], as shown in Figure 35. Also note that the VCO subsystem registers are not directly accessible. They are written to the VCO subsystem via PLL Register 0x05. See Figure 39 and the VCO Serial Port Interface (VSPI) section for more information about the VCO subsystem SPI. The frequency limits of the VCO can be measured using the BIST features of the autocalibration machine by setting Register 0x0A[10] = 1, which freezes the VCO switches in one position. VCO switches may then be written manually with the varactor biased at the nominal midrail voltage used for autocalibration. For example, to measure the VCO maximum frequency use Switch 0, written to the VCO subsystem via Register 0x05 = 000000001 0000 VCO_ID, where VCO_ID = 000b. When autocalibration is enabled (Register 0x0A[11] = 0), and a new frequency is written, autocalibration runs. The VCO frequency error relative to the command frequency is measured and the results are written to Register 0x11[19:0], where Register 0x11[19] is the sign bit. The result is written in terms of VCO count error (see Equation 4). For example, if the expected VCO is 2 GHz, the reference is 50 MHz, and n is 6, expect to measure 2000/(50/26) = 2560 counts. If a difference of −5 counts is measured in Register 0x11, then it means 2555 counts were actually measured. Hence, the actual frequency of the VCO is 5/2560 low, or 1.99609375 GHz, ±1 count ~ ±781 kHz. PLL SUBSYSTEM Charge Pump (CP) and Phase Detector (PD) The phase detector (PD) has two inputs, one from the reference path divider and one from the RF path divider. When in lock, these two inputs are at the same average frequency and are fixed at a constant average phase offset with respect to each other. The frequency of operation of the PD is fPD. Most formulae related to step size, Δ-Σ modulation, timers, and so forth are functions of the operating frequency of the PD, fPD. fPD is also referred to as the comparison frequency of the PD. The PD compares the phase of the RF path signal with that of the reference path signal and controls the charge pump output current as a linear function of the phase difference between the two signals. The output current varies linearly over a full ±2π radians (±360°) of input phase difference. Charge Pump A simplified diagram of the charge pump is shown in Figure 43. The CP consists of four programmable current sources, two controlling the CP gain (Up Gain Register 0x09[13:7], and Down Gain Register 0x09[6:0]) and two controlling the CP offset, where the magnitude of the offset is set by Register 0x09[20:14], and the direction is selected by Register 0x09[21] = 1 for up and Register 0x09[22] = 1 for down offset. CP gain is used at all times, whereas CP offset is recommended for fractional mode of operation only. Typically, the CP up and down gain settings are set to the same value (Register 0x09[13:7] = Register 0x09[6:0]). Rev. A | Page 20 of 48 Data Sheet HMC832 Charge Pump Gain Charge pump up and down gains are set by Register 0x09[6:0] and Register 0x09[13:7], respectively. The current gain of the pump in amps/radian is equal to the gain setting of this register (Register 0x09) divided by 2π. For example, if both Register 0x09[13:7] and Register 0x09[6:0] are set to 50 decimal, the output current of each pump is 1 mA, and the phase frequency detector gain is kP = 1 mA/2π radians, or 159 μA/rad. See the Charge Pump (CP) and Phase Detector (PD) section for more information. Typical CP gain setting is set to 2 mA to 2.5 mA; however, lower values can also be used. Note that values less than 1 mA may result in degraded phase noise performance. UP GAIN REG0x09[13:7] 0mA TO 2.54mA 20µA STEP UP OFFSET REG0x09[21] 0µA TO 635µA 5µA STEP REG0x09[20:14] UP REF PATH PD LOOP FILTER VCO PATH DN 0mA TO 2.54mA 20µA STEP Figure 43. Charge Pump Gain and Offset Control Rev. A | Page 21 of 48 12827-048 DN OFFSET REG0x09[22] 0µA TO 635µA 5µA STEP REG0x09[20:14] DN GAIN REG0x09[6:0] HMC832 Data Sheet Charge Pump Phase Offset In integer mode, the phase detector operates with zero offset. The divided reference signal and the divided VCO signal arrive at the phase detector inputs at the same time. Integer mode does not require any CP offset current. When operating in integer mode, disable CP offset in both directions (up and down) by writing Register 0x09[22:21] = 00b, and set the CP offset magnitude to zero by writing Register 0x09[20:14] = 0. In fractional mode, CP linearity is of paramount importance. Any nonlinearity degrades phase noise and spurious performance. These nonlinearities are eliminated by operating the PD with an average phase offset, either positive or negative (either the reference or the VCO edge always arrives first at the PD, that is, leads). Operation with CP offset influences the required configuration of the lock detect function. See the description of the lock detect function in the Lock Detect section. Phase Detector Functions Register 0x0B, the phase detector register, allows manual access to control special phase detector features. Setting Register 0x0B[5] = 0 masks the PD up output, which prevents the charge pump from pumping up. Setting Register 0x0B[6] = 0, masks the PD down output, which prevents the charge pump from pumping down. Clearing both Register 0x0B[5] and Register 0x0B[6] tristates the charge pump while leaving all other functions operating internally. A programmable CP offset current source is used to add dc current to the loop filter and to create the desired phase offset. Positive current causes the VCO to lead, negative current causes the reference to lead. PD force up (Register 0x0B[9] = 1) and PD force down (Register 0x0B[10] = 1) allows the charge pump to be forced up or down, respectively. This forces the VCO to the ends of the tuning range, which is useful in testing the VCO. The CP offset is controlled via Register 0x09. The phase offset is scaled from 0° to 360°, where they arrive a full cycle late. Reference Input Stage RVDD Required CP Offset = min [(4.3 × 10−9 × fPD × ICP), 0.25 × ICP] CP CURRENT = 2.5mA 600 CP CURRENT = 2mA 400 300 CP CURRENT = 1mA XREFP 20Ω 80Ω Vb Figure 45. Reference Path Input Stage The reference buffer provides the path from an external reference source (generally crystal-based) to the R divider, and eventually to the phase detector. The buffer has two modes of operation controlled by Register 0x08[21]. High gain (Register 0x08[21] = 0) is recommended below 200 MHz, and high frequency (Register 0x08[21] = 1) for 200 MHz to 350 MHz operation. The buffer is internally dc biased with 100 Ω internal termination. For a 50 Ω match, add an external 100 Ω resistor to ground followed by an ac coupling capacitor (impedance less than 1 Ω). At low frequencies, a relatively square reference is recommended to maintain a high input slew rate. At higher frequencies, use a square or sinusoid. 200 100 0 20 40 60 80 PHASE DETECTOR FREQUENCY (MHz) 100 12827-049 RECOMMENDED OFFSET CURRENT (µA) 700 0 100Ω (9) where: fPD is the comparison frequency of the phase detector (Hz). ICP is the full-scale current setting (A) of the switching charge pump (set in Register 0x09[6:0] and Register 0x09[13:7]). 500 AC COUPLE 12827-050 The specific level of charge pump offset current (Register 0x09, Bits[20:14]) is provided in Equation 9 and plotted in Figure 44. Figure 44. Recommended CP Offset Current vs. PD Frequency for Typical CP Gain Currents, Calculated Using Equation 9 Do not allow the required CP offset current to exceed 25% of the programmed CP current. It is recommended to enable the up offset and disable the down offset by writing Register 0x09, Bits[22:21] = 01b. Table 8 shows the recommended operating regions for different reference frequencies. If operating outside these regions, the device usually still operates, but with degraded reference path phase noise performance. When operating at 50 MHz, the input referred phase noise of the PLL is between −148 dBc/Hz and −150 dBc/Hz at a 10 kHz offset, depending upon the mode of operation. To avoid degradation of the PLL noise contribution, the input reference signal should be 10 dB better than this floor. Note that such low levels are only necessary if the PLL is the dominant noise contributor and these levels are required for the system goals. Rev. A | Page 22 of 48 Data Sheet HMC832 Table 8. Reference Sensitivity Reference Input Frequency (MHz) 0.5 V/ns Recommended Yes Yes Yes Yes Yes Okay Okay Square Input Recommended Swing (V p-p) Minimum Maximum 0.6 2.5 0.6 2.5 0.6 2.5 0.6 2.5 0.6 2.5 0.9 2.5 1.2 2.5 Recommended No No Okay Yes Yes Yes Yes Sinusoidal Input Recommended Power Range (dBm) Minimum Maximum No No No No 8 15 6 15 5 15 4 12 3 8 Reference Path, R Divider The HMC832 supports two lock detect modes: The reference path, R divider is based on a 14-bit counter and can divide input signals by values from 1 to 16,383 and is controlled via Register 0x02. • • RF Path, N Divider The main RF path divider is capable of average divide ratios between 219 − 5 (524,283) and 20 in fractional mode, and 219 − 1 (524,287) to 16 in integer mode. The VCO frequency range divided by the minimum N divider value places practical restrictions on the maximum usable PD frequency. For example, a VCO operating at 1.5 GHz in fractional mode with a minimum N divider value of 20 has a maximum PD frequency of 75 MHz. Lock Detect The lock detect (LD) function verifies that the HMC832 is generating the desired frequency. It is enabled by writing Register 0x07[3] = 1. The HMC832 provides an LD indicator in one of two ways • • As an output available on the LD_SDO pin of the HMC832, (configuration is required to use the LD_SDO pin for LD purposes, for more information, see the Serial Port and Configuring the LD_SDO Pin for LD Output sections). Or reading from Register 0x12[1], where Bit 1 = 1 indicates a locked condition and Bit 1 = 0 indicates an unlocked condition. The LD circuit expects the divided VCO edge and the divided reference edge to appear at the PD within a user specified time period (window), repeatedly. Either signal may arrive first, only the difference in arrival times is significant. The arrival of the two edges within the designated window increments an internal counter. When the count reaches and exceeds a user specified value (Register 0x07[2:0]) the HMC832 declares lock. Failure in registering the two edges in any one window resets the counter and immediately declares an unlocked condition. Lock is deemed to be reestablished when the counter reaches the user specified value (Register 0x07[2:0]) again. Analog LD, that only supports a fixed window size of 10 ns. Analog LD mode is selected by writing Register 0x07[6] = 0. Digital LD, that supports a user configurable window size, programmed in Register 0x07[11:7]. Digital LD is selected by writing Register 0x07[6] = 1. Lock Detect Configuration Optimal spectral performance in fractional mode requires CP current and CP offset current configuration discussed in detail in the Charge Pump (CP) and Phase Detector (PD) section. These settings in Register 0x09 impact the required LD window size in fractional mode of operation. To function, the required lock detect window size is provided by Equation 10 in fractional mode and Equation 11 in integer mode. LD Window (sec) = ICP Offset (A)   1   + 2.66 × 10−9 (sec) +   f (Hz) × I (A) ( Hz ) f PD PD CP   2 LD Window (sec ) = 1 2 × f PD (10) (11) where: fPD is the comparison frequency of the phase detector. ICP Offset is the charge pump offset current (Register 0x09[20:14]). ICP is the full-scale current setting of the switching charge pump (Register 0x09[6:0] or Register 0x09[13:7]). If the result provided by Equation 10 is equal to 10 ns, analog LD can be used (Register 0x07[6] = 0); otherwise, digital LD is necessary (Register 0x07[6] = 1). Table 9 lists the required Register 0x07 settings to appropriately program the digital LD window size. From Table 9, select the closest value in the digital LD window size columns to the ones calculated in Equation 10 and Equation 11, and program Register 0x07[11:10] and Register 0x07[9:7] accordingly. Rev. A | Page 23 of 48 HMC832 Data Sheet Table 9. Typical Digital Lock Detect Window LD Timer Speed Register 0x07 Bits[11:10] Fastest 00 01 10 Slowest 11 LD Timer Divide Setting Register 0x07, Bits[9:7] Digital Lock Detect Window Size Nominal Value (ns) 6.5 8 11 17 29 53 100 195 7 8.9 12.8 21 36 68 130 255 7.1 9.2 13.3 22 38 72 138 272 7.6 10.2 15.4 26 47 88 172 338 000 001 010 011 100 101 110 111 Digital Window Configuration Example Assuming, fractional mode, with a 50 MHz PD and a • • • Charge pump gain of 2 mA (Register 0x09[13:7] = 0x64, Register 0x09[6:0] = 0x64), Up offset (Register 0x09[22:21] = 01b) Offset current magnitude of +400 μA (Register 0x09[20:14] = 0x50) Applying Equation 10, the required LD window size is: LD Window (sec) =   0.4 × 10 −3 (A) 1   + 2.66 × 10 −9 (sec) + −3 6 6 × × × × 50 10 ( Hz ) 2 10 ( A ) 50 10 ( Hz )   2 = 13.33 ns Locating the Table 9 value that is closest to this result is, in this case, 13.3 ≈ 13.33. To set the digital LD window size, program Register 0x07[11:10] = 10b and Register 0x07[9:7] = 010b, according to Table 9. There is always a good solution for the lock detect window for a given operating point. The user should understand, however, that one solution does not fit all operating points. As observed from Equation 10 and Equation 11, if the charge pump offset or PD frequency is changed significantly, then the lock detect window may need to be adjusted. Configuring the LD_SDO Pin for LD Output Setting Register 0x0F[7] = 1 and Register 0x0F[4:0] = 1 displays the lock detect flag on the LD_SDO pin of the HMC832. When locked, LD_SDO is high. As the name suggests, LD_SDO pin is multiplexed between the LD and the serial data output (SDO) signals. Therefore, LD is available on the LD_SDO pin at all times except when a serial port read is requested, in which case the pin reverts temporarily to the serial data output pin, and returns to the lock detect flag after the read is completed. LD can be made available on LD_SDO pin at all times by writing Register 0x0F[6] = 1. In that case, the HMC832 does not provide any readback functionality because the SDO signal is not available. Cycle Slip Prevention (CSP) When changing VCO frequency and the VCO is not yet locked to the reference, the instantaneous frequencies of the two PD inputs are different, and the phase difference of the two inputs at the PD varies rapidly over a range much greater than ±2π radians. Because the gain of the PD varies linearly with phase up to ±2π, the gain of a conventional PD cycles from high gain, when the phase difference approaches a multiple of 2π, to low gain, when the phase difference is slightly larger than a multiple of 0 radians. The output current from the charge pump cycles from maximum to minimum, even though the VCO has not yet reached its final frequency. The charge on the loop filter small capacitor may actually discharge slightly during the low gain portion of the cycle. This can make the VCO frequency reverse temporarily during locking. This phenomenon is known as cycle slipping. Cycle slipping causes the pull-in rate during the locking phase to vary cyclically. Cycle slipping increases the time to lock to a value greater than that predicted by normal small signal Laplace transform analysis. The HMC832 PD features an ability to reduce cycle slipping during acquisition. The cycle slip prevention (CSP) feature increases the PD gain during large phase errors. The specific phase error that triggers the momentary increase in PD gain is set via Register 0x0B[8:7]. Frequency Tuning The HMC832 VCO subsystem always operates in fundamental frequency of operation (1500 MHz to 3000 MHz). The HMC832 generates frequencies below its fundamental frequency (25 MHz to 1500 MHz) by tuning to the appropriate fundamental frequency and selecting the appropriate output divider setting (divide by 2/4/6/ … 60/62) in VCO_REG 0x02[5:0]. The HMC832 automatically controls frequency tuning in the fundamental band of operation, for more information see the VCO Autocalibration section. To tune to frequencies below the fundamental frequency range ( To program Register 0x04, the closest integer-N boundary frequency, fN, that is less than the smallest channel VCO frequency, fVCO1, must be calculated (fN = floor(fVCO1/fPD)). Using the current example: The start phase of the fractional modulator digital phase accumulator (DPA) can be set to one of four possible default values via the seed register, Register 0x06[1:0]. The HMC832 automatically reloads the start phase (seed value) into the DPA every time a new fractional frequency is selected. Certain zero or binary seed values may cause spurious energy correlation at specific frequencies. For most cases a random (not zero and not binary) start seed is recommended (Register 0x06[1:0] = 2). SOFT RESET AND POWER-ON RESET The HMC832 features a hardware power-on reset (POR). All chip registers are reset to default states approximately 250 μs after power up. The PLL subsystem SPI registers can also be soft reset by an SPI write to Register 0x00. Note that the soft reset does not clear the SPI mode of operation referred to in the Serial Port section. Note that the VCO subsystem is not affected by the PLL soft reset; the VCO subsystem registers can only be reset by removing the power supply. If external power supplies or regulators have rise times slower than 250 μs, then it is advised to write to the SPI reset register (Register 0x00[5] = 1) immediately after power up, before any other SPI activity. This write procedure ensures starting from a known state. Rev. A | Page 28 of 48 Data Sheet HMC832 POWER-DOWN MODE Note that the VCO subsystem is not affected by the CEN or soft reset. Therefore, device power-down is a two step process. 1. Power down the VCO by writing 0 to VCO Register 1 via Register 0x05 . 2. Power-down the PLL by pulling the CEN pin (Pin 17) low (assuming there are no SPI overrides (Register 0x01[0] = 1)). Pulling the CEN pin low disables all analog functions and internal clocks. Current consumption typically drops below 10 μA in the power-down state. The serial port still responds to normal communication in power-down mode. Register 0x0F to 1 to prevent automux of the SDO. The phase noise performance at this output is poor and uncharacterized. Also, the GPO output should not be toggling during normal operation because it may degrade the spectral performance. Note that there are additional controls available, which may be helpful when sharing the bus with other devices.   To disable the driver completely, set Register 0x08[5] = 0 (it takes precedence over all else). To disable either the pull-up or pull-down sections of the driver, Register 0x0F[8] = 1 or Register 0x0F[9] = 1, respectively. It is possible to ignore the CEN pin by setting Register 0x01[0] = 0. Control of the power-down mode then comes from the serial port register, Register 0x01[1]. Example scenarios are listed in Table 11. The signals that are available on the GPO are selected by changing the GPO Select Register 0x0F[4:0]. It is also possible to leave various blocks turned on when in power-down (see Register 0x01), as listed in Table 10. Table 11. Driver Scenarios Scenario Drive SDO During Reads, Tristate Otherwise (Allow Bus Sharing) Drive SDO During Reads, Lock Detect Otherwise Table 10. Bit and Block Assignments for Register 0x01 Bit Assignment Bit 2 Bit 3 Bit 4 Bit 5 Bit 6 Bit 7 Block Assignment Internal bias reference sources PD block CP block Reference path buffer VCO path buffer Digital I/O test pads Always Drive Lock Detect To mute the output but leave the PLL and VCO locked, see the VCO Output Mute Function section. GENERAL-PURPOSE OUTPUT (GPO) PIN The PLL shares the LD_SDO (lock detect/serial data output) pin to perform various functions. Although the pin is most commonly used to read back registers from the chip via the SPI, it is also capable of exporting a variety of signals and real-time test waveforms (including lock detect). It is driven by a tristate CMOS driver with ~200 Ω ROUT. It has logic associated with it to dynamically select whether the driver is enabled, and to decide which data to export from the chip. In its default configuration, after power-on reset, the output driver is disabled, and only drives during appropriately addressed SPI reads. This allows it to share the output with other devices on the same bus. To monitor any of the GPO signals, including lock detect, set Register 0x0F[7] = 1 to keep the SDO driver always on. This stops the LDO driver from tristating and means that the SDO line cannot be shared with other devices. The HMC832 naturally switches away from the GPO data and exports the SDO during an SPI read. To prevent this automatic data selection, and always select the GPO signal, set Bit 6 of Set GPO Select Register 0x0F[4:0] = 00001b (default) Set Register 0x0F[7] = 1, prevent GPO driver disable Set Register 0x0F[6] = 1, prevent automux of SDO Set the GPO Select Register 0x0F[4:0] = 00001 (default) Set Register 0x0F[7] = 1, prevent GPO driver disable CHIP IDENTIFICATION PLL subsystem version information may be read by reading the content of read only register, chip_ID in Register 0x00. It is not possible to read the VCO subsystem version. SERIAL PORT The SPI protocol has the following general features:   The pin driver is enabled if the chip is addressed; that is, the last three bits of SPI cycle = 000b before the rising edge of SEN. If SEN rises before SCK has clocked in an invalid (non zero) chip address, the HMC832 starts to drive the bus. Action None required    3-bit chip address, can address up to eight devices connected to the serial bus. Wide compatibility with multiple protocols from multiple vendors. Simultaneous write/read during the SPI cycle. 5-bit address space. 3-wire for write only capability, 4-wire for read/write capability. Typical serial port operation can be run with SCLK at speeds up to 50 MHz. Serial Port Initialization at Power-Up At power-up, it is required that both SEN and SCK lines are initially held low, and that the first rising edge occurs on the SCK line before any rising edges occur on the SEN line. Rev. A | Page 29 of 48 HMC832 Data Sheet 3. If the first rising edge occurs on the SEN line before it does on the SCK line the HMC832LP6GE SPI interface does not function. In that case, it is necessary to cycle the power to the off and on, and repeat the previous recommended sequence (hold both signals low at power-up and ensure that the first rising edge occurs on the SCK line). The master places a 5-bit register address to be written to, R4:R0, MSB first, on the next five falling edges of SCLK (25th to 29th falling edges). The slave shifts the register bits on the next five rising edges of SCLK (25th to 29th rising edges). The master places 3-bit chip address, A2:A0, MSB first, on the next three falling edges of SCLK (30th to 32nd falling edges). Analog Devices reserves Chip Address A2 to Chip Address A0 = 000 for all RF PLLs with integrated VCOs. The slave shifts the chip address bits on the next three rising edges of SCLK (30th to 32nd rising edges). The master asserts SEN after the 32nd rising edge of SCLK. The slave registers the SDI data on the rising edge of SEN. 4. 5. Serial Port Write Operation SPI write specifications are listed in the Table 2 in the SPI Write Timing Characteristics section and a typical write cycle is shown in Figure 47. The SPI write operation is as follows: 2. The master (host) places 24-bit data, D23:D0, MSB first, on SDI on the first 24 falling edges of SCLK. The slave (HMC832) shifts in data on SDI on the first 24 rising edges of SCLK. 7. 8. t5 2 1 3 22 24 23 25 30 26 31 32 SCK t1 t2 t6 SDI x D23 D22 D2 D1 D0 R4 R3 R0 A2 A1 A0 x SEN t3 Figure 47. Serial Port Timing Diagram, Write Rev. A | Page 30 of 48 t4 12827-052 1. 6. Data Sheet HMC832 Serial Port Read Operation 5. In general, the LD_SDO line is always active during the write cycle. During any SPI cycle, LD_SDO contains the data from the current address written in Register 0x0[4:0]. If Register 0x0[4:0] is not changed, the same data is always present on LD_SDO during a SPI cycle. 6. If a read is required from a specific address, it is necessary to write the required address to Register 0x0[4:0] in the first SPI cycle, then in the next SPI cycle, the desired data becomes available on LD_SDO. A typical read cycle is shown in Figure 48. 7. 8. 9. 10. An example of the two cycle procedure to read from any random address is as follows: 1. 2. 3. 4. The master (host), on the first 24 falling edges of SCLK places 24-bit data, D23:D0, MSB first, on SDI as shown in Figure 48. Set D23:D5 to zero. D4:D0 = address of the register to be read on the next cycle. The slave (HMC832) shifts in data on SDI on the first 24 rising edges of SCK. The master places the 5-bit register address , R4:R0, (the read address register), MSB first, on the next five falling edges of SCK (25th to 29th falling edges). R4:R0 = 00000. The slave shifts the register bits on the next five rising edges of SCK (25th to 29th rising edges). 11. 12. 13. 14. Rev. A | Page 31 of 48 The master places the 3-bit chip address, A2:A0, MSB first, on the next three falling edges of SCK (30th to 32nd falling edges). The chip address is always 000b. The slave shifts the chip address bits on the next three rising edges of SCK (30th to 32nd rising edges). The master asserts SEN after the 32nd rising edge of SCK. The slave registers the SDI data on the rising edge of SEN. The master clears SEN to complete the the address transfer of the two part read cycle. If a write data to the chip is not needed at the same time as the second cycle occurs, then it is recommended to simply rewrite the same contents on SDI to Register 0x00 on the readback portion of the cycle. The master places the same SDI data as the previous cycle on the next 32 falling edges of SCK. The slave (HMC832) shifts the SDI data on the next 32 rising edges of SCK. The slave places the desired read data (that is, data from the address specified in Register 0x00[4:0] of the first cycle) on LD_SDO, which automatically switches to SDO mode from LD mode, disabling the LD output. The master asserts SEN after the 32nd rising edge of SCK to complete the cycle and revert back to lock detect on LD_SDO. HMC832 Data Sheet FIRST CYCLE 18 1 19 24 20 25 29 31 30 32 SCK SDI x D5 LD/GPO D4 x x R4 D0 READ ADDRESS t5 LD_SDO OR TRISTATE t7 t2 t1 R3 x x x A0 A1 x CHIP ADDRESS = 000 REGISTER ADDRESS = 00000 x A2 R0 t6 x x x x LD/GPO x SEN t3 t4 SECOND CYCLE 1 19 18 20 24 25 29 31 30 32 SCK t7 t1 SDI LD_SDO x t6 D23 LD/GPO D5 D23 D22 D4 R4 D0 D2 D1 D0 R3 R4 A2 R0 R0 A1 A2 A0 A1 x A0 LD/GPO1 t3 1FOR MORE INFORMATION ON USING THE GPO PIN WHILE IN SPI OPEN MODE PLEASE SEE SERIAL PORT SECTION. Figure 48. Serial Port Timing Diagram, Read Rev. A | Page 32 of 48 12827-053 SEN Data Sheet HMC832 APPLICATIONS INFORMATION Using the HMC832 with a tunable reference, as shown in Figure 51, it is possible to drastically improve spurious emissions performance across all frequencies. Large bandwidth (25 MHz to 3000 MHz), industry leading phase noise and spurious performance, excellent noise floor (−160 dBc/Hz), coupled with a high level of integration make the HMC832 ideal for a variety of applications; as an RF or IF stage local oscillator (LO). PLL HMC832 DAC ÷2 PLL HMC1044LP3E HMC832 12827-040 DAC HMC795LP5E HMC900LP5E Figure 49. HMC832 in a Typical Transmit Chain PLL HMC832 HMCAD1520 ADC CMIO 0 PLL HMC1044LP3E CMQO HMC832 HMCAD1520 ADC HMC960LP4E HMC597LP4E HMC900LP5E Figure 50. HMC832 in a Typical Receive Chain CRYSTAL OSCILLATOR TUNABLE REFERENCE 25MHz TO 100MHz HMC832 PLL HMC832 Figure 51. HMC832 Used as a Tunable Reference for HMC832 Rev. A | Page 33 of 48 12827-042 PLL 12827-041 90 HMC832 Data Sheet POWER SUPPLY it is filtered by the loop filter. The internal HMC832 setup and divide ratios are changed in the opposite direction accordingly so that the HMC832 generates identical output frequency as shown in Figure 18, without the spurious emissions inside the loop bandwidth. Using these same procedures, in Figure 19, the graph is generated by observing and plotting the magnitude of the largest spur only, at any offset, at each output frequency, while using a fixed 50 MHz reference and a tunable 47.5 MHz reference. The HMC832 is a high performance, low noise device. In some cases, phase noise and spurious performance may be degraded by noisy power supplies. To achieve maximum performance and ensure that power supply noise does not degrade the performance of the HMC832 it is recommended to use the Analog Devices low noise, high power supply rejection ratio (PSRR) regulator, the HMC1060LP3E. Using the HMC1060LP3E lowers the design risk and cost, and ensures that the performance shown in the Typical Performance Characteristics section can be achieved. The HMC832 features an internal autocalibration process that seamlessly calibrates the HMC832 when a frequency change is executed (see Figure 27 and Figure 30). Typical frequency settling time that can be expected after any frequency change (writes to Register 0x03 or Register 0x04 ) is shown in Figure 27 with autocalibration enabled (Register 0x0A[11] = 0). A frequency hop of 5 MHz is shown in Figure 27; however the settling time is independent of the size of the frequency change. Any size frequency hop has a similar settling time with autocalibration enabled. Figure 32 shows the typical tuning voltage after calibration where once the HMC832 is calibrated at any temperature, the calibration setting holds across the entire operating range of the HMC832 (−40°C to +85°C). Figure 32 shows that the tuning voltage is maintained within a narrow operating range for worst case scenarios where calibration was executed at one temperature extreme and the device is operating at the other extreme. PROGRAMMABLE PERFORMANCE TECHNOLOGY For low power applications that do not require maximum noise floor performance, the HMC832 features the ability to reduce current consumption by 50 mA (power consumption by 165 mW) at the cost of decreasing phase noise floor performance by ~5 dB. High performance is enabled by writing VCO_REG 0x03[1:0] = 3d, and it is disabled (low current consumption mode enabled) by writing VCO_REG 0x03[1:0] = 1d. High performance mode improves noise floor performance at the cost of increased current consumption. Resulting current consumption and phase noise floor performance are shown in Figure 33 and Figure 36. LOOP FILTER AND FREQUENCY CHANGES C1 R2 R4 C3 VTUNE C4 12827-037 R3 CP C2 For applications that require fast frequency changes, the HMC832 supports manual calibration that enables faster settling times (see Figure 28 and Figure 31). Manual calibration needs to be executed only once for each individual HMC832, at any temperature, and is valid across all temperature operating ranges of the HMC832. More information about manual calibration is available in the Manual VCO Calibration for Fast Frequency Hopping section. A Frequency hop of 5 MHz is shown in Figure 28 and Figure 31; however, the settling time is independent of the size of the frequency change. Any size frequency hop has a similar settling time with autocalibration disabled (Register 0x0A[11] = 1). Figure 52. Loop Filter Design All PLLs with integrated VCOs exhibit integer boundary spurs at harmonics of the reference frequency. As seen in Figure 18, the plot shows the worst case spurious scenario where the harmonic of the reference frequency (50 MHz) is within the loop filter bandwidth of the fundamental frequency of the HMC832. The tunable reference changes the reference frequency from 50 MHz in Figure 18 to 47.5 MHz in Figure 16 to distance the harmonic of the reference frequency (spurious emissions) away from the fundamental output frequency of the HMC832 so that Table 12. Loop Filter Designs Used in Typical Performance Characteristics Graphs Loop Filter Type Type 1 1 Type 2 2 Type 3 3 Loop Filter BW (kHz) 127 75 214 Loop Filter Phase Margin 61° 61° 71° C1 (pF) 390 270 56 C2 (nF) 10 27 1.8 C3 (pF) 82 200 NA C4 (pF) 82 390 NA R2 (Ω) 750 430 2200 R3 (Ω) 300 390 0 R4 (Ω) 300 390 0 Loop Filter Design See Figure 52 Loop Filter Type 1 is for best integrated phase noise. Loop filter bandwidth is designed for 50 MHz PD frequency, CP = 1.6 mA at 2.2 GHz output in fractional mode. Loop Filter Type 2 is suggested to use for best far out phase noise. Loop filter BW is designed for 50 MHz PD frequency, CP = 1.6 mA at 2.2 GHz output in fractional mode. 3 Loop Filter Type 3 is suggested to use for best integrated phase noise at integer mode. Loop filter bandwidth is designed for 50 MHz PD frequency, CP = 2.5 mA at 3 GHz output in integer mode. 1 2 Rev. A | Page 34 of 48 Data Sheet HMC832 RF PROGRAMMABLE OUTPUT RETURN LOSS MUTE MODE The HMC832 features programmable RF output return loss (VCO_REG 0x03[5]) and 12 dB of programmable gain (VCO_REG 0x07[3:0]), as shown in Figure 26 and Figure 25. Maximum output power is achieved with a high return loss setting (VCO_REG 0x03[5] = 0), as shown in Figure 22. Setting VCO_REG 0x03[5] = 1 improves return loss for applications that require it at the cost of reduced RF output power (see Figure 22). The HMC832 features a configurable mute mode, along with the ability to independently turn off outputs on both RF_N and RF_P output pins. Figure 35 shows isolation measured at the output when the mute mode is on (VCO_REG 0x03[8:7] = 3d), and when the mute mode is off (VCO_REG 0x03[8:7] = 1d), with either both outputs disabled (VCO_REG 0x03[3:2] = 0) or one output enabled and the other disabled (VCO_REG 0x03[3:2] = 1d). Rev. A | Page 35 of 48 HMC832 Data Sheet PLL REGISTER MAP ID, READ ADDRESS, AND RST REGISTERS The ID register is read only, the read address/RST strobe register is write only, and the RST register is read/write. Table 13. Register 0x00, ID Register (Read Only) Bits 23:0 Type R Name CHIP_ID Width 24 Default A7975 Description HMC832LP6GE chip ID Table 14. Register 0x00, Read Address/RST Strobe Register (Write Only) Bits 4:0 5 23:6 1 Type W W W Name Read address Soft reset Not defined Width 5 1 18 Default1 N/A N/A N/A Description Read address for next cycle, open mode only. This is a write only register. Soft reset for both SPI modes (set to 0 for proper operation). Not defined (set to 0 for proper operation). N/A means not applicable. Table 15. Register 0x01, RST Register (Default 0x000002) Bits 0 Type R/W Name RST_CHIPEN_PIN_SELECT Width 1 Default 0 1 9:2 R/W R/W RST_CHIPEN_FROM_SPI Reserved 1 8 1 0 Description 1 = take PLL enable via CEN pin, see the Power-Down Mode section 0 = take PLL enable via SPI (RST_CHIPEN_FROM_SPI) Register 0x01[1] PLL enable bit of the SPI Reserved REFERENCE DIVIDER, INTEGER, AND FRACTIONAL FREQUENCY REGISTERS Table 16. Register 0x02, REFDIV Register (Default 0x000001) Bits 13:0 Type R/W Name RDIV Width 14 Default 1 Description Reference divider R value (see Equation 12). Using the divider requires the Analog EN Register 0x08[3] = 1 and divider, minimum = 1d, maximum = 16,383d. Table 17. Register 0x03, Frequency Register, Integer Part (Default 0x000019) Bits 18:0 Type R/W Name INTG_REG Width 19 Default 25d Description Integer divider register. These bits are the VCO divider integer part, used in all modes, see Equation 12. Fractional mode. Maximum 219 − 4 = 0x7FFFC = 524,284d. Integer mode. Minimum 16d. Maximum 219− 1 = 0x7FFFF = 524,287d. Table 18. Register 0x04, Frequency Register, Fractional Part (Default 0x000000) Bits 23:0 Type R/W Name FRAC Width 24 Default 0 Description VCO divider fractional part (24-bit unsigned), see the Fractional Frequency Tuning section. These bits are used in fractional mode only (NFRAC = Register 0x04/224). Minimum = 0d; maximum = 224 − 1. Rev. A | Page 36 of 48 Data Sheet HMC832 VCO SPI REGISTER Register 0x05 is a read/write register. However, Register 0x05 holds only the contents of the last transfer to the VCO subsystem. Therefore, it is not possible to read the full contents of the VCO subsystem. Only the content of the last transfer to the VCO subsystem can be read. Also note special considerations for autocalibration related to Register 0x05. Register 0x05 is a special register used for indirect addressing of the VCO subsystem. Writes to Register 0x05 are automatically forwarded to the VCO subsystem by the VCO SPI state machine controller. Table 19. Register 0x05, VCO SPI Register (Default 0x000000) Bits 2:0 6:3 Type R/W R/W Name VCO_ID VCO_REGADDR Width 3 4 Default 0 0 15:7 R/W VCO_DATA 9 0 Description Internal VCO subsystem ID. VCO subsystem register address. These bits are for interfacing with the VCO. See the VCO Serial Port Interface (VSPI) section. VCO subsystem data. These bits are for the data to be written to the VCO subsystem. DELTA-SIGMA CONFIGURATION Table 20. Register 0x06, Delta-Sigma Configuration Register (Default 0x200B4A) Bit 1:0 Type R/W Name Seed Width 2 Default 2 6:2 7 R/W R/W Reserved FRAC_BYPASS 5 1 18d 0 10:8 11 R/W R/W Initialization SD enable 3 3d 1 1 9 1 0 1 Description Selects the seed in fractional mode. Writes to this register are stored in theHMC832 and are loaded into the modulator only when a frequency change is executed and if Register 0x06[8] = 1. 00: 0 seed. 01: LSB seed. 02: 0xB29D08 seed. 03: 0x50F1CD seed. Reserved. Bypass fractional mode. In the bypass fractional modulator, output is ignored, but fractional modulator continues to be clocked when FRAC_RST = 1. This bit can be used to test the isolation of the digital fractional modulator from the VCO output in integer mode. 0: use modulator, required for fractional mode 1: bypass modulator, required for integer mode. Program to 7d. This bit controls whether autocalibration starts on an integer or a fractional write. 0: disables fractional core, use for integer mode or integer mode with CSP. 1: enables fractional core, required for fractional mode, or integer isolation testing. Reserved. Program to 0. 1 0 Reserved. 20:12 21 R/W R/W 22 R/W Reserved Automatic clock configuration Reserved Rev. A | Page 37 of 48 HMC832 Data Sheet LOCK DETECT REGISTER Table 21. Register 0x07, Lock Detect Register (Default 0x00014D) Bit 2:0 Type R/W Name LKD_WINCNT_MAX Width 3 Default 5d 3 R/W 1 1 5:4 6 R/W R/W Enable internal lock detect Reserved Lock detect window type Description Lock detect window sets the number of consecutive counts of divided VCO that must land inside the lock detect window to declare lock 0: 5 1: 32 2: 96 3: 256 4: 512 5: 2048 6: 8192 7: 65,535 See the Serial Port section 2 1 0 1 Reserved Lock detection window timer selection 2 1: digital programmable timer 0: analog one shot, nominal 10 ns window Lock detection, digital window duration 9:7 R/W LD digital window duration 3 11:10 R/W LD digital timer frequency control 2 0 12 13 R/W R/W Reserved Automatic relock: one try 31 1 0 0 0: half cycle 1: one cycle 2: two cycles 3: four cycles 4: eight cycles 5: 16 cycles 6: 32 cycles 7: 64 cycles Lock detect digital timer frequency control, see the Lock Detect section for more information 00: fastest 11: slowest Reserved 1: attempts to relock if lock detect fails for any reason; tries one time only ANALOG ENABLE (EN) REGISTER Table 22. Register 0x08, Analog EN Register, (Default 0xC1BEFF) Bit 4:0 5 Type R/W R/W Name Reserved GPO_PAD_EN Width 5 1 Default 31d 1 9:6 10 R/W R/W 4 1 11d 1 20:11 R/W Reserved VCO buffer and prescaler bias enable Reserved Description Reserved 0: disables the LD/SDO pin 1: enables GPO port or allows a shared SPI When Bit 5 = 1 and Register 0xF[7] = 1, the LD_SDO pin is always driven, which is required for use of the GPO port When Bit 5 = 1 and Register 0xF[7] = 0, SDO is off when an unmatched chip address is seen on the SPI, allowing a shared SPI with other compatible devices Reserved VCO buffer and prescaler bias enable 1 55d Reserved Rev. A | Page 38 of 48 Data Sheet Bit 21 Type R/W 23:22 R/W HMC832 Name High frequency reference Reserved Width 1 Default 0 Description Program to 1 for XTAL > 200 MHz 2 3d Reserved CHARGE PUMP REGISTER Table 23. Register 0x09, Charge Pump Register (Default 0x403264) Bit 6:0 Type R/W Name CP DN gain Width 7 Default 100d 0x64 13:7 R/W CP UP gain 7 100d 0x64 20:14 R/W Offset magnitude 7 0 21 22 23 R/W R/W R/W Offset up enable Offset DN enable Reserved 1 1 1 0 1 0 Description Charge pump DN gain control, 20 μA per step. Affects fractional phase noise and lock detect settings. 0d = 0 μA 1d = 20 μA 2d = 40 μA … 127d = 2.54 mA Charge pump up gain control, 20 μA per step. Affects fractional phase noise and lock detect settings. 0d = 0 μA 1d = 20 μA 2d = 40 μA … 127d = 2.54 mA Charge pump offset control, 5 μA per step. Affects fractional phase noise and lock detect settings. 0d = 0 μA 1d = 5 μA 2d = 10 μA … 127d = 635 μA Recommended setting = 1 in fractional mode, 0 otherwise. Recommended setting = 0. Reserved. AUTOCALIBRATION REGISTER Table 24. Register 0x0A, VCO Autocalibration Configuration Register (Default 0x002205) Bit 2:0 Type R/W Name VTUNE resolution Width 3 Default 5 9:3 10 11 12 R/W R/W R/W R/W Reserved Force curve Autocalibration disable No VSPI trigger 7 1 1 1 64d 0 0 0 Description R divider cycles 0: 1 cycle 1: 2 cycles 2: 4 cycles … 7: 256 cycles Program 8d Program 0 Program 0 for normal operation using VCO autocalibration 0: normal operation 1: this bit disables the serial transfers to the VCO subsystem (via Register 0x05) Rev. A | Page 39 of 48 HMC832 Data Sheet Bit 14:13 Type R/W Name FSM/VSPI clock select Width 2 Default 1 16:15 R/W Reserved 2 0 Description These bits set the autocalibration FSM and VSPI clock (50 MHz maximum) 0: input crystal reference 1: input crystal reference divide by 4 2: input crystal reference divide by 16 3: input crystal reference divide by 32 Reserved PHASE DETECTOR (PD) REGISTER Table 25. Register 0x0B, PD Register (Default 0x0F8061) Bit 2:0 4:3 5 6 8:7 Type R/W R/W R/W R/W R/W Name PD_DEL_SEL Reserved PD_UP_EN PD_DN_EN CSP mode Width 3 2 1 1 2 Default 1 0 1 1 0 9 10 23:11 R/W R/W R/W Force CP up Force CP DN Reserved 1 1 13 0 0 496d 0x1F0 Description Sets PD reset path delay (recommended setting is 001). Reserved. Enables the PD up output. Enables the PD down output. Cycle slip prevention mode. This delay varies by ±10% with temperature, and ±12% with process. Extra current is driven into the loop filter when the phase error is larger than the following: 0 = disabled 1 = 5.4 ns 2 = 14.4 ns 3 = 24.1 ns Forces CP up output to turn on; use for test only. Forces CP down output to turn on; use for test only. Reserved. EXACT FREQUENCY MODE REGISTER Table 26. Register 0x0C, Exact Frequency Mode Register (Default 0x000000) Bit 13:0 Type R/W Name Number of Channels per fPD Width 14 Default 0 Description The comparison frequency divided by the correction rate must be an integer. Frequencies at exactly the correction rate have zero frequency error. 0: disabled. 1: disabled. 2:16383d (0x3FFF). Rev. A | Page 40 of 48 Data Sheet HMC832 GENERAL-PURPOSE, SERIAL PORT INTERFACE, AND REFERENCE DIVIDER (GPO_SPI_RDIV) REGISTER Table 27. Register 0x0F, GPO_SPI_RDIV Register (Default 0x000001) Bit 4:0 Type R/W Name GPO_SELECT Width 5 Default 1d Description The signal selected here is an output to the SDO pin when the SDO pin is enable via Register 0x08[5] 0: data from Register 0x0F[5] 1: lock detect output 2: lock detect trigger 3: lock detect window output 4: ring oscillator test 5: pull-up hard from CSP 6: pull-down hard from CSP 7: reserved 8: reference buffer output 9: reference divider output 10: VCO divider output 11: modulator clock from VCO divider 12: auxiliary clock 13: auxiliary SPI clock 14: auxiliary SPI enable 15: auxiliary SPI data output 16: PD down 17: PD up 18: SD3 clock delay 19: SD3 core clock 20: autostrobe integer write 21: autostrobe fractional write 22: autostrobe auxiliary SPI 23: SPI latch enable 24: VCO divider sync reset 25: seed load strobe 26 to 29: not used 30: SPI output buffer enable 31: soft reset, RST 5 6 R/W R/W GPO test data Prevent automux SDO 1 1 0 0 1: GPO test data 1: outputs GPO data only 0: automuxes between SDO and GPO data 7 R/W LDO driver always on 1 0 1: LD_SDO pin driver always on 0: LD_SDO pin driver only on during SPI read cycle 8 9 R/W R/W Disable PFET Disable NFET 1 1 0 0 Rev. A | Page 41 of 48 HMC832 Data Sheet VCO TUNE REGISTER The VCO tune register is a read only register. Table 28. Register 0x10, VCO Tune Register (Default 0x000020) Bit 7:0 Type R Name VCO switch setting Width 8 Default 32 8 R Autocalibration busy 1 0 Description Indicates the VCO switch setting selected by the autocalibration state machine to yield the nearest free running VCO frequency to the desired operating frequency. Not valid when Register 0x10[8] = 1, autocalibration busy. Note that when a manual change is made to the VCO switch settings, this register does not indicate the current VCO switch position. VCO subsystems may not use all the MSBs, in which case the unused bits are don’t care. 0 = highest frequency. 1 = second highest frequency. … 255 = lowest frequency. Busy when the autocalibration state machine is searching for the nearest switch setting to the requested frequency. SAR REGISTER The SAR register is a read only register. Register 0x11, SAR Register (Default 0x07FFFF) Bit 18:0 19 Type R R Name SAR error magnitude counts SAR error sign Width 19 1 Default 219 to 1 0 Description SAR error magnitude counts SAR error sign 0 = +ve 1 = −ve Default 0 0 Description GPO state Lock detect status 1 = locked 0 = unlocked Default 4697d Description Reserved GENERAL-PURPOSE 2 REGISTER The GPO2 register is a read only register. Table 29. Register 0x12, GPO2 Register (Default 0x000000) Bit 0 1 Type R R Name GPO Lock detect Width 1 1 BUILT-IN SELF TEST REGISTER The BIST register is a read only register. Table 30. Register 0x13, BIST Register (Default 0x001259) Bit 16:0 Type R Name Reserved Width 17 Rev. A | Page 42 of 48 Data Sheet HMC832 VCO SUBSYSTEM REGISTER MAP The VCO subsystem uses indirect addressing via Register 0x05. For more detailed information on how to write to the VCO subsystem, see the VCO Serial Port Interface (VSPI) section. The VCO tuning register is write only. Table 31. VCO_REG 0x00 Tuning Bit 0 Type W Name CAL Width 1 Default 0 8:1 W CAPS 8 16 Description VCO tune voltage is redirected to a temperature compensated calibration voltage VCO subband selection 0: maximum frequency 1111 1111: minimum frequency VCO ENABLE REGISTER The VCO enable register is a write only register. Table 32. VCO_REG 0x01 Enable Bit 0 1 2 3 Type W W W W Name Master enable VCO subsystem VCO enable PLL buffer enable Input/output master enable Width 1 1 1 1 Default 1 1 1 1 4 5 7:6 8 W W W W Reserved Output stage enable Reserved Reserved 1 1 2 1 1 1 3 1 Description 0: all VCO subsystem blocks are turned off. Enables VCOs. Enables PLL buffer to N divider. Enables output stage and the output divider. It does not enable/disable the VCO. Reserved. Output stage enable. Reserved. Reserved. Example: Disabling the Output Stage of the VCO Subsystem Register 0x05[7] = 1; master enable. To disable the output stage of the VCO subsystem of the HMC832, clear Bit 5 in VCO_REG 0x01. If the other bits are left unchanged, then write 1 1101 1111 into VCO_REG 0x01. The VCO subsystem register is accessed via a write to PLL subsystem Register 0x05 = 1 1101 1111 0001 00 = 0xEF88. Register 0x05[9] = 1; PLL buffer enable. Register 0x05[2:0] = 000; VCO subsystem ID 0. Register 0x05[14:13] = 11b. Register 0x05[6:3] = 0001; VCO subsystem register address. Register 0x05[15] = 1; don’t care. Register 0x05[8] = 1; VCO enable. Register 0x05[10] = 1; I/O master enable. Register 0x05[11] = 1; reserved. Register 0x05[12] = 0; disable the output stage. Rev. A | Page 43 of 48 HMC832 Data Sheet VCO OUTPUT DIVIDER REGISTER Register 0x05[2:0] = 000; Subsystem ID 0 This is a write only register. Note that to write 0_1111_1110 into VCO_REG 0x02 VCO subsystem (VCO_ID = 000b), and set the VCO output divider to divide by 62, the following needs to be written to Register 0x05 = 0_1111_1110, 0010, 000 b. Register 0x05[6:3] = 0010; VCO Register Address 2d. Register 0x05[16:7] = 0_1111_1110; divide by 62, maximum output RF gain. Table 33. VCO_REG 0x02 VCO Output Divider Bit 5:0 Type W Name RF divide ratio Width 6 Default 1 8:6 W Reserved 3 0 Description 0: mutes the output when VCO_REG 0x03[8:7] = 0d 1: fo 2: fo/2 3: invalid, defaults to 2 4: fo/4 5: invalid, defaults to 4 6: fo/6 … 60: fo/60 61: invalid, defaults to 60 62: fo/62 > 62 invalid, defaults to 62 Reserved VCO CONFIGURATION REGISTER The VCO configuration register is a write only register. Table 34. VCO_REG 0x03 Configuration Bit 1:0 Type W Name Programmable performance mode Width 2 Default 2 2 W RF_N output enable 1 0 3 W RF_P output enable 1 0 4 5 W W Reserved Return loss 1 1 1 0 6 8:7 W W Reserved Mute mode 1 2 0 1 Description Selects output noise floor performance level at a cost of increased current consumption. 01: low current consumption mode. 11: high performance mode. Other states (00 and 10) not supported. Enables the output on RF_N pin. Required for differential operation, or single-ended output on the RF_N pin. Enables the output on RF_P pin. Required for differential operation, or single-ended output on the RF_P pin. Reserved. 0: return loss = −5 dB typical (highest output power). 1: return loss = −10 dB typical. Reserved. Defines when the mute function is enabled (the output is muted), see the VCO Output Mute Function section, and Figure 35 for more information. 00: enables mute when the divide ratio, VCO_REG 0x02[5:0] = 0. This enables the HMC832 to be backwards compatible to the HMC830 mute function. 01: during VCO calibration (see the VCO Calibration section for more details). 10: not supported. 11: mute all RF outputs (unconditional). Rev. A | Page 44 of 48 Data Sheet HMC832 VCO CALIBRATION/BIAS, CF CALIBRATION, AND MSB CALIBRATION REGISTERS These registers are write only. Note that, specified performance is only guaranteed with the required settings in Table 35 only; other settings are not supported. Table 35. VCO_REG 0x04 CAL/Bias Bit 0 Type W Name Initialization Width 9 Default 201d Description Reserved Width 9 Default 170d Description Reserved Width 9 Default 255d Description Reserved Table 36. VCO_REG 0x05 CF_CAL Bit 8:0 Type W Name Reserved Table 37. VCO_REG 0x06 MSB Calibration Bit 8:0 Type W Name Reserved VCO OUTPUT POWER CONTROL The VCO power control register is write only. Table 38. VCO_REG 0x07 Output Power Control Bit 3:0 Type W Name Output stage gain control Width 4 Default 1 4 8:5 W W Initialization Reserved 1 4 0 4d Rev. A | Page 45 of 48 Description Output stage gain control in 1 dB steps 0d: 0 dB gain 1d: 1 dB gain 2d: 2 dB gain … 10d: 10 dB gain 11d: 11 dB gain Program to 1d Program 4d HMC832 Data Sheet EVALUATION PRINTED CIRCUIT BOARD (PCB) The default register configuration file included in the Analog Devices PLL evaluation software sets the comparison frequency to 50 MHz (R = 1, that is, Register 0x02 = 1). As with all PLLs and PLL with integrated VCOs, modifying the comparison frequency or charge pump (CP) current results in changes to the loop dynamics and ultimately, phase noise performance. When making these changes there are several items to keep in mind:  12827-039  Figure 53. Silk Screen and PCB Traces Top Layer CP offset current setting: refer to the Charge Pump (CP) and Phase Detector (PD) section. LD configuration: refer to the Lock Detect section. To redesign the loop filter for a particular application, download the PLL design software tool by clicking on the software download link on the HMC832 product page. Analog Devices PLL design enables users to accurately model and analyze performance of all Analog Devices PLLs, PLLs with integrated VCOs, and clock generators. It supports various loop filter topologies, and enables users to design custom loop filters and accurately simulate resulting performance. For more information, see the Loop Filter and Frequency Changes section. 12827-139 For evaluation purposes, the HMC832 evaluation board is shipped with an on-board, low cost, low noise (100 ppm), 50 MHz VCXO, enabling evaluation of most parameters including phase noise without any external references. Figure 54. Silk Screen and PCB Traces Bottom Layer The circuit board used in the application uses RF circuit design techniques. Signal lines have 50 Ω impedance whereas the package ground leads and exposed paddle are connected directly to the ground plane similar to that shown in Figure 53 and Figure 54. Use a sufficient number of via holes to connect the top and bottom ground planes. The evaluation circuit board shown Figure 53 and Figure 54 is available from Analog Devices upon request. CHANGING EVALUATION BOARD REFERENCE FREQUENCY AND CP CURRENT CONFIGURATION The evaluation board is provided with a 50 MHz on board reference oscillator, and Type 1 loop filter configuration, as shown in Figure 52 (~127 kHz bandwidth, see Table 12). Exact phase or frequency measurements require the HMC832 to use the same reference as the measuring instrument. To accommodate this requirement, the HMC832 evaluation board includes the HMC1031MS8E; a simple low current integer-N PLL that can lock the on-board VCXO to an external 10 MHz reference input commonly provided by most test equipment. To lock the HMC832 to an external 10 MHz reference, connect the external reference output to the J5 input of the HMC832 evaluation board and change the HMC1031MS8E integer divider value to 5 by changing the switch settings, D1 = 1 (SW1 to SW4 closed), and D0 = 0 (SW2 to SW3 open), for more information see the HMC1031MS8E data sheet. EVALUATION KIT CONTENTS The evaluation kit contains one HMC832LP6GE evaluation PCB, a USB interface board, a six-foot USB A-male to USB B-female cable, a CD ROM that contains the user manual, evaluation PCB schematic, evaluation software, and Analog Devices PLL design software. To order the evaluation kit, see the Ordering Guide section for the product number. Rev. A | Page 46 of 48 Data Sheet HMC832 OUTLINE DIMENSIONS BOT TOM VIEW FOR PROPER CONNECTION OF THE EXPOSED PAD, REFER TO THE PIN CONFIGURATION AND FUNCTION DESCRIPTIONS SECTION OF THIS DATA SHEET. 11-10-2014-A NOTES: 1. PACKAGE BODY MATERIAL: LOW STRESS INJECTION MOLDED PLASTIC SILICA AND SILICON IMPREGNATED. 2. LEAD AND GROUND PADDLE MATERIAL: COPPER ALLOY. 3. LEAD AND GROUND PADDLE PLATING: 100% MATTE TIN. 4. DIMENSIONS ARE IN INCHES [MILLIMETERS]. 5. LEAD SPACING TOLERANCE IS NON-CUMULATIVE. 6. PAD BURR LENGTH SHALL BE 0.15mm MAX. PAD BURR HEIGHT SHALL BE 0.25mm max. 7. PACKAGE WARP SHALL NOT EXCEED 0.05mm. 9. REFER TO HITTITE APPLICATION NOTE FOR SUGGESTED PCB LAND PATTERN. Figure 55. 40-Lead Quad Flat No-Lead Package [QFN] 6 mm × 6 mm Body, Very Thin Quad Dimensions shown in inches and [millimeters] 11-03-2014-A TOP VIEW Figure 56. Tape and Reel Outline Dimensions Dimensions shown in millimeters Rev. A | Page 47 of 48 HMC832 Data Sheet ORDERING GUIDE Model 1 HMC832LP6GE Lead Finish 100% matte Sn MSL Rating MSL1 Temperature −40°C to +85°C Package Description 40-Lead Quad Flat No-Lead Package [QFN], Low Stress Injection Molded Plastic Qty. HMC832LP6GETR 100% matte Sn MSL1 −40°C to +85°C 40-Lead Quad Flat No-Lead Package [QFN], Low Stress Injection Molded Plastic, 7” Tape and Reel Evaluation Kit Evaluation Board 500 EKIT01-HMC832LP6G EVAL01-HMC832LP6G 1 2 E = RoHS Compliant Part. Four-digit lot number XXXX. ©2014 Analog Devices, Inc. All rights reserved. Trademarks and registered trademarks are the property of their respective owners. D12827-0-11/14(A) Rev. A | Page 48 of 48 Brand 2 H 832 XXXX H 832 XXXX
HMC832LP6GE 价格&库存

很抱歉,暂时无法提供与“HMC832LP6GE”相匹配的价格&库存,您可以联系我们找货

免费人工找货
HMC832LP6GE
  •  国内价格
  • 1+61.87880
  • 10+59.78830
  • 100+54.77110
  • 500+52.26250

库存:0