LTC1702CGN

LTC1702CGN

  • 厂商:

    AD(亚德诺)

  • 封装:

    SSOP-24_8.65X3.9MM

  • 描述:

    IC REG CTRLR BUCK 24SSOP

  • 数据手册
  • 价格&库存
LTC1702CGN 数据手册
LTC1702 Dual 550kHz Synchronous 2-Phase Switching Regulator Controller U FEATURES DESCRIPTIO ■ The LTC®1702 is a dual switching regulator controller optimized for high efficiency with low input voltages. It includes two complete, on-chip, independent switching regulator controllers each designed to drive a pair of external N-channel MOSFET devices in a voltage mode feedback, synchronous buck configuration. The LTC1702 uses a constant-frequency, true PWM design switching at 550kHz, minimizing external component size and cost and maximizing load transient performance. The synchronous buck architecture automatically shifts to discontinuous and then to Burst ModeTM operation as the output load decreases, ensuring maximum efficiency over a wide range of load currents. The LTC1702 features an onboard reference trimmed to 0.5% and can provide better than 1% regulation at the converter outputs. Open-drain logic outputs indicate whether either output has risen to within 5% of the final output voltage and an optional latching FAULT mode protects the load if the output rises 15% above the intended voltage. Each channel can be enabled independently; with both channels disabled, the LTC1702 shuts down and supply current drops below 100µA. ■ ■ ■ ■ ■ ■ ■ ■ ■ Two Independent Controllers in One Package Two Sides Run Out-of-Phase to Minimize CIN All N-Channel External MOSFET Architecture No External Current Sense Resistors Excellent Output Regulation: 1% Total Output Accuracy 550kHz Switching Frequency Minimizes External Component Size 1A to 25A Output Current per Channel High Efficiency over Wide Load Current Range Quiescent Current Drops Below 100µA in Shutdown Small 24-Pin Narrow SSOP Package U APPLICATIO S ■ ■ ■ ■ Microprocessor Core and I/O Supplies Multiple Logic Supply Generator Distributed Power Applications High Efficiency Power Conversion , LTC and LT are registered trademarks of Linear Technology Corporation. Burst Mode is a registered trademark of Linear Technology Corporation. All other trademarks are the property of their respective owners. Protected by U.S. Patents including 5481178, 5847554, 6304066, 6307356, 6580258. U TYPICAL APPLICATIO Dual Output High Power 3.3V/2.5V Logic Supply VIN = 5V ±10% COUT1, COUT2: PANASONIC EEFUE0G181R CIN: KEMET TS10X337M010AS D1, D2: MOTOROLA MBR0520LT1 D3, D4: MOTOROLA MBRS320T3 L1, L2: SUMIDA CEP125-1R0 Q1 TO Q8: FAIRCHILD FDS6670A 1µF 10Ω D2 1 2 3 Q1 Q2 4 5 1µF + COUT1 180µF ×4 D3 Q3 Q4 27k 6 7 1.2k 8 10k 1% 820pF 9 1µF 10 4.75k 1% VIN 47k 680pF 11 27pF 12 PVCC IMAX2 + BOOST1 BOOST2 BG1 BG2 TG1 TG2 SW1 IMAX1 PGOOD1 FCB SW2 LTC1702 PGND PGOOD2 FAULT RUN/SS RUN/SS2 COMP1 COMP2 SGND FB2 FB1 VCC 24 27k 23 10µF CIN 330µF ×3 1µF 22 Q5 Q6 L2 1µH 21 20 VOUT2 3.3V/15A 19 Q7 Q8 18 D4 1.6k 17 680pF 16 15 15.8k 1% + COUT2 180µF ×4 1µF 1µF 68k 14 4.99k 1% VIN 13 27pF 3300pF 10k 10k PWRGD1 D1 1µF 1µF L1 1µH VOUT1 2.5V AT 15A 10µF 1702 TA01 PWRGD2 FAULT 1702fa 1 LTC1702 U W U U W W W ABSOLUTE MAXIMUM RATINGS PACKAGE/ORDER INFORMATION (Note 1) TOP VIEW Supply Voltage VCC ........................................................................ 7V BOOSTn ............................................................... 15V BOOSTn – SWn .................................................... 7V Input Voltage SWn .......................................................... – 1V to 8V All Other Inputs ......................... – 0.3V to VCC + 0.3V Peak Output Current < 10µs TGn, BGn ............................................................... 5A Operating Temperature Range LTC1702C ............................................... 0°C to 70°C LTC1702I ........................................... – 40°C to 85°C Storage Temperature Range ................. – 65°C to 150°C Lead Temperature (Soldering, 10 sec).................. 300°C PVCC 1 24 IMAX2 BOOST1 2 23 BOOST2 BG1 3 22 BG2 TG1 4 21 TG2 SW1 5 20 SW2 IMAX1 6 19 PGND PGOOD1 7 18 PGOOD2 FCB 8 17 FAULT RUN/SS1 9 16 RUN/SS2 COMP1 10 15 COMP2 SGND 11 14 FB2 FB1 12 13 VCC GN PACKAGE 24-LEAD NARROW PLASTIC SSOP TJMAX = 125°C, θJA = 100°C/ W ORDER PART NUMBER LTC1702CGN LTC1702IGN Order Options Tape and Reel: Add #TR Lead Free: Add #PBF Lead Free Tape and Reel: Add #TRPBF Lead Free Part Marking: http://www.linear.com/leadfree/ Consult LTC Marketing for parts specified with wider operating temperature ranges. ELECTRICAL CHARACTERISTICS The ● denotes specifications which apply over the full operating temperature range, otherwise specifications are TA = 25°C. VCC = 5V unless otherwise specified. (Note 3) SYMBOL PARAMETER CONDITIONS MIN TYP MAX UNITS Main Control Loop VCC VCC Supply Voltage PVCC PVCC Supply Voltage (Note 2) ● 3 7 V ● 3 7 V 2.7 BVCC BOOST Pin Voltage VBOOST – VSW (Note 2) ● ICC VCC Supply Current Test Circuit 1, CL = 0pF RUN/SS1 = RUN/SS2 = 0V (Note 5) ● ● 2.2 30 8 100 mA µA IPVCC PVCC Supply Current Test Circuit 1, CL = 0pF (Note 4) RUN/SS1 = RUN/SS2 = 0V (Note 5) ● ● 2.2 6 6 100 mA µA IBOOST BOOST Pin Current Test Circuit 1, CL = 0pF (Note 4) RUN/SS1 = RUN/SS2 = 0V ● ● 1.3 0.1 3 10 mA µA VFB Feedback Voltage Test Circuit 1, CL = 0pF, LTC1702C Test Circuit 1, CL = 0pF, LTC1702I ● ● 0.800 0.800 0.808 0.810 V V ∆VFB Feedback Voltage Line Regulation VCC = 3V to 7V ● ±0.005 ±0.05 %/V ● ±0.001 ±1 µA (Note 6) ● 0.1 ±0.2 % 0.8 0.85 IFB Feedback Current ∆VOUT Output Voltage Load Regulation VFCB FCB Threshold ∆VFCB FCB Feedback Hysteresis IFCB FCB Pin Current VRUN RUN/SS Pin RUN Threshold ISS Soft-Start Source Current ● 0.792 0.790 0.75 7 20 ● V mV ±0.001 ±1 0.45 0.55 0.65 V –2 – 3.5 –6 µA ● RUN/SSn = 0V V µA 1702fa 2 LTC1702 ELECTRICAL CHARACTERISTICS The ● denotes specifications which apply over the full operating temperature range, otherwise specifications are TA = 25°C. VCC = 5V unless otherwise specified. (Note 3) SYMBOL PARAMETER CONDITIONS MIN TYP MAX UNITS ● 475 550 750 kHz Switching Characteristics fOSC Oscillator Frequency Test Circuit 1, CL = 0pF ΦOSC2 Converter 2 Oscillator Phase Relative to Converter 1 (Note 6) DCMIN1 Minimum Duty Cycle VFB < VMAX ● 7 DCMIN2 Minimum Duty Cycle VFB > VMAX ● 0 ● 87 180 DEG 10 % % DCMAX Maximum Duty Cycle 90 93 % tNOV Driver Nonoverlap Test Circuit 1, CL = 2000pF (Note 7) ● 40 100 ns t r, tf Driver Rise/Fall Time Test Circuit 1, CL = 2000pF (Note 7) ● 12 80 ns Feedback Amplifier ● AVFB FB DC Gain GBW FB Gain Bandwidth IERR FB Sink/Source Current ● VMIN MIN Comparator Threshold ● VMAX MAX Comparator Threshold ● 74 ±3 85 dB 25 MHz ±10 760 815 mA 785 mV 840 mV 40 dB Current Limit Loop AVILIM ILIM Gain IIMAX IMAX Source Current IMAX = 0V, LTC1702C IMAX = 0V, LTC1702I ● ● –7 –7 –10 –10 –13 –14 µA µA VPGOOD PGOOD Trip Point VFB Relative to Regulated VOUT ● – 10 –5 –2 % VOLPG PGOOD Output Low Voltage PGOOD = 1mA ● 0.03 0.1 V IPGOOD PGOOD Output Leakage ● ±0.1 ±1 µA tPGOOD PGOOD Delay Time VFAULT FAULT Trip Point VFB Relative to Regulated VOUT ● VOLF FAULT Output Low Voltage IFAULT = 1mA ● IFAULT FAULT Output Current VFAULT = 0V tFAULT FAULT Delay Time VFB > VFAULT to FAULT Status Outputs VFB < VPGOOD to PGOOD Note 1: Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. Exposure to any Absolute Maximum Rating condition for extended periods may affect device reliability and lifetime. Note 2: PVCC and BVCC (VBOOST – VSW) must be greater than VGS(ON) of the external MOSFETs used to ensure proper operation. Note 3: All currents into device pins are positive; all currents out of device pins are negative. All voltages are referenced to ground unless otherwise specified. (Note 7) (Note 7) µs 100 + 10 + 15 + 20 % 0.03 0.1 V – 10 µA 25 µs Note 4: Supply current in normal operation is dominated by the current needed to charge and discharge the external MOSFET gates. This current will vary with supply voltage and the external MOSFETs used. Note 5: Supply current in shutdown is dominated by external MOSFET leakage and may be significantly higher than the quiescent current drawn by the LTC1702, especially at elevated temperature. Note 6: This parameter is guaranteed by correlation and is not tested directly. Note 7: Rise and fall times are measured using 10% and 90% levels. Delay and nonoverlap times are measured using 50% levels. 1702fa 3 LTC1702 U W TYPICAL PERFOR A CE CHARACTERISTICS Efficiency vs Load Current VIN = 5V VOUT = 2.5V 90 35 VIN = 5V VOUT = 1.8V ILOAD = 0A-10A-0A ±2.2% MAX DEVIATION VOUT = 3.3V VOUT = 1.6V DRIVER SUPPLY CURRENT (mA) EFFICIENCY (%) 100 MOSFET Driver Supply Current vs Gate Capacitance Transient Response 20mV/ DIV 80 70 0 5 10 LOAD CURRENT (A) TEST CIRCUIT 1 ONE DRIVER LOADED 30 MULTIPLY BY # OF ACTIVE DRIVERS TO OBTAIN TOTAL 25 DRIVER SUPPLY CURRENT 20 15 10 5 0 15 10µs/DIV 1702 G02 2000 4000 6000 8000 GATE CAPACITANCE (pF) 0 1702 G01 1702 G03 Normalized Frequency vs Temperature Supply Current vs Temperature 2.5 2.0 PVCC NORMALIZED FREQUENCY (%) 2.2 VCC 2.0 1.8 1.6 1.4 BOOST1, BOOST2 1.2 1.0 – 50 – 25 0 50 75 25 TEMPERATURE (°C) 100 125 VCC = 5V 1.3 1.5 1.2 1.0 1.1 0.5 1.0 0 –0.5 0.7 0.6 –2.0 0.5 –2.5 –50 –25 0.4 –50 –25 50 25 0 75 TEMPERATURE (°C) 100 VCC = 5V 60 NONOVERLAP (ns) 4.0 3.5 3.0 50 25 0 75 TEMPERATURE (°C) 50 100 125 1702 G06 Nonoverlap Time vs Temperature 70 4.5 SOURCE CURRENT (µA) 125 1702 G05 RUN/SS Source Current vs Temperature Driver Rise/Fall vs Temperature 15 TEST CIRCUIT 1 CL = 2000pF TEST CIRCUIT 1 CL = 2000pF 14 TG FALLING EDGE BG RISING EDGE 40 30 BG FALLING EDGE TG RISING EDGE 20 13 12 11 2.5 2.0 –50 –25 0.8 –1.5 1702 G04 5.0 VPVCC = 5V VBOOST – VSW = 5V 0.9 –1.0 RISE/FALL TIME (ns) SUPPLY CURRENT (mA) TEST CIRCUIT 1 CL = 0pF Driver RON vs Temperature 1.4 RON (Ω) 2.6 2.4 10000 10 50 25 75 0 TEMPERATURE (°C) 100 125 1702 G07 0 –50 –25 50 25 75 0 TEMPERATURE (°C) 100 125 1702 G08 12 –50 –25 50 25 0 75 TEMPERATURE (°C) 100 125 1702 G09 1702fa 4 LTC1702 U U U PIN FUNCTIONS PVCC (Pin 1): Driver Power Supply Input. PVCC provides power to the two BGn output drivers. PVCC must be connected to a voltage high enough to fully turn on the external MOSFETs QB1 and QB2. PVCC should generally be connected directly to VIN. PVCC requires at least a 1µF bypass capacitor directly to PGND. BOOST1 (Pin 2): Controller 1 Top Gate Driver Supply. The BOOST1 pin supplies power to the floating TG1 driver. BOOST1 should be bypassed to SW1 with a 1µF capacitor. An additional Schottky diode from VIN to BOOST1 pin will create a complete floating charge-pumped supply at BOOST1. No other external supplies are required. BG1 (Pin 3): Controller 1 Bottom Gate Drive. The BG1 pin drives the gate of the bottom N-channel synchronous switch MOSFET, QB1. BG1 is designed to drive up to 10,000pF of gate capacitance directly. If RUN/SS1 goes low, BG1 will go low, turning off QB1. If FAULT mode is tripped, BG1 will go high and stay high, keeping QB1 on until the power is cycled. TG1 (Pin 4): Controller 1 Top Gate Drive. The TG1 pin drives the gate of the top N-channel MOSFET, QT1. The TG1 driver draws power from the BOOST1 pin and returns to the SW1 pin, providing true floating drive to QT1. TG1 is designed to drive up to 10,000pF of gate capacitance directly. In shutdown or fault modes, TG1 will go low. SW1 (Pin 5): Controller 1 Switching Node. SW1 should be connected to the switching node of converter 1. The TG1 driver ground returns to SW1, providing floating gate drive to the top N-channel MOSFET switch, QT1. The voltage at SW1 is compared to IMAX1 by the current limit comparator while the bottom MOSFET, QB1, is on. IMAX1 (Pin 6): Controller 1 Current Limit Set. The IMAX1 pin sets the current limit comparator threshold for controller 1. If the voltage drop across the bottom MOSFET, QB1, exceeds the magnitude of the voltage at IMAX1, controller 1 will go into current limit. The IMAX1 pin has an internal 10µA current source pull-up, allowing the current threshold to be set with a single external resistor to PGND. See the Current Limit Programming section for more information on choosing RIMAX. PGOOD1 (Pin 7): Controller 1 Power Good. PGOOD1 is an open-drain logic output. PGOOD1 will pull low whenever FB1 falls 5% below its programmed value. When RUN/SS1 is low (side 1 shut down), PGOOD1 will go high. FCB (Pin 8): Force Continuous Bar. The FCB pin forces both converters to maintain continuous synchronous operation regardless of load when the voltage at FCB drops below 0.8V. FCB is normally tied to VCC. To force continuous operation, tie FCB to SGND. FCB can also be connected to a feedback resistor divider from a secondary winding on one converter’s inductor to generate a third regulated output voltage. Do not leave FCB floating. RUN/SS1 (Pin 9): Controller 1 Run/Soft-start. Pulling RUN/SS1 to SGND will disable controller 1 and turn off both of its external MOSFET switches. Pulling both RUN/SS pins down will shut down the entire LTC1702, dropping the quiescent supply current below 100µA. A capacitor from RUN/SS1 to SGND will control the turn-on time and rate of rise of the controller 1 output voltage at power-up. An internal 3.5µA current source pull-up at RUN/SS1 pin sets the turn-on time at approximately 500ms/µF. COMP1 (Pin 10): Controller 1 Loop Compensation. The COMP1 pin is connected directly to the output of the first controller’s error amplifier and the input to the PWM comparator. An RC network is used at the COMP1 pin to compensate the feedback loop for optimum transient response. SGND (Pin 11): Signal Ground. All internal low power circuitry returns to the SGND pin. Connect to a low impedance ground, separated from the PGND node. All feedback, compensation and soft-start connections should return to SGND. SGND and PGND should connect only at a single point, near the PGND pin and the negative plate of the CIN bypass capacitor. FB1 (Pin 12): Controller 1 Feedback Input. FB1 should be connected through a resistor network to VOUT1 to set the output voltage. The loop compensation network for controller 1 also connects to FB1. VCC (Pin 13): Power Supply Input. All internal circuits except the output drivers are powered from this pin. VCC should be connected to a low noise power supply voltage between 3V and 7V and should be bypassed to SGND with at least a 1µF capacitor in close proximity to the LTC1702. 1702fa 5 LTC1702 U U U PIN FUNCTIONS FB2 (Pin 14): Controller 2 Feedback Input. See FB1. COMP2 (Pin 15): Controller 2 Loop Compensation. See COMP1. RUN/SS2 (Pin 16): Controller 2 Run/Soft-start. See RUN/ SS1. FAULT (Pin 17): Output Overvoltage Fault (Latched). The FAULT pin is an open-drain output with an internal 10µA pull-up. If either regulated output voltage rises more than 15% above its programmed value for more than 25µs, the FAULT output will go high and the entire LTC1702 will be disabled. When FAULT is high, both BG pins will go high, turning on the bottom MOSFET switches and pulling down the high output voltage. The LTC1702 will remain latched in this state until the power is cycled. When FAULT mode is active, the FAULT pin will be pulled up with an internal 10µA current source. Tying FAULT directly to PGND will disable latched FAULT mode and will allow the LTC1702 to resume normal operation when the overvoltage fault is removed. PGOOD2 (Pin 18): Controller 2 Power Good. See PGOOD1. PGND (Pin 19): Power Ground. The BGn drivers return to this pin. Connect PGND to a high current ground node in close proximity to the sources of external MOSFETs, QB1 and QB2, and the VIN and VOUT bypass capacitors. SW2 (Pin 20): Controller 2 Switching Node. See SW1. TG2 (Pin 21): Controller 2 Top Gate Drive. See TG1. BG2 (Pin 22): Controller 2 Bottom Gate Drive. See BG1. BOOST2 (Pin 23): Controller 2 Top Gate Driver Supply. See BOOST1. IMAX2 (Pin 24): Controller 2 Current Limit Set. See IMAX1. W BLOCK DIAGRAM PVCC FCB VCC BOOST1,2 BURST LOGIC TG1,2 DRIVE LOGIC SW1,2 BG1,2 OSC 550kHz 90% DUTY CYCLE PGND 1VP-P SGND DIS 3.5µA SOFT START RUN/SS1,2 100µs DELAY COMP1,2 25µs DELAY ILIM 10µA + FB MIN – MAX 760mV 840mV FAULT FLT IMAX1,2 800mV PGOOD1,2 920mV FROM OTHER CONTROLLER FB1,2 SHUTDOWN TO THIS CONTROLLER 1702 BD SHUTDOWN TO ENTIRE CHIP 550mV FROM OTHER CONTROLLER 1702fa 6 LTC1702 TEST CIRCUIT Test Circuit 1 5V 0.1µF IBOOST1 ICC VCC BOOST1 fOSC MEASURED 5V CL CL 10k IBOOST2 TG2 BG1 BG2 SW1 SW2 IMAX1 IMAX2 CL LTC1702 PGOOD2 RUN/SS1 RUN/SS2 5V VPGOOD2 VFAULT 2k COMP2 FB1 FB2 GND CL 10k PGOOD1 COMP1 VFB1 100µF BOOST2 FAULT 2k + PVCC TG1 FCB VPGOOD1 IPVCC VFB2 PGND 1702 TC U W U U APPLICATIONS INFORMATION OVERVIEW The LTC1702 is a dual, step-down (buck), voltage mode feedback switching regulator controller. It is designed to be used in a synchronous switching architecture with two external N-channel MOSFETs per channel. It is intended to operate from a low voltage input supply (7V maximum) and provide a high power, high efficiency, precisely regulated output voltage. Several features make it particularly suited for microprocessor supply regulation. Output regulation is extremely tight, with DC line and load regulation and initial accuracy better than 1%, and total regulation including transient response inside of 3% with a properly designed circuit. The 550kHz switching frequency allows the use of physically small, low value external components without compromising performance. The LTC1702’s internal feedback amplifier is a 25MHz gain-bandwidth op amp, allowing the use of complex multipole/zero compensation networks. This allows the feedback loop to maintain acceptable phase margin at higher frequencies than traditional switching regulator controllers allow, improving stability and maximizing transient response. The 800mV internal reference allows regulated output voltages as low as 800mV without external level shifting amplifiers. The LTC1702’s synchronous switching logic transitions automatically into Burst Mode operation, maximizing efficiency with light loads. Onboard power-good and overvoltage (OV) fault flags indicate when the output is in regulation or an OV fault has occurred. The OV flag can be set to latch the device off when an OV fault has occurred, or to automatically resume operation when the fault is removed. The LTC1702 takes a low input voltage and generates two lower output voltages at very high currents. Its strengths are small size, unmatched regulation and transient response and high efficiency. This combination makes it ideal for providing multiple low voltage logic supplies to microprocessors or high density ASICs in systems using a “2-step” regulation architecture, used in portable and advanced desktop computers. 1702fa 7 LTC1702 U W U U APPLICATIONS INFORMATION 2-Step Conversion “2-step” architectures use a primary regulator to convert the input power source (batteries or AC line voltage) to an intermediate supply voltage, often 5V. This intermediate voltage is then converted to the low voltage, high current supplies required by the system using a secondary regulator— the LTC1702. 2-step conversion eliminates the need for a single converter that converts a high input voltage to a very low output voltage, often an awkward design challenge. It also fits naturally into systems that continue to use the 5V supply to power portions of their circuitry, or have excess 5V capacity available as newer circuit designs shift the current load to lower voltage supplies. Each regulator in a typical 2-step system maintains a relatively low step-down ratio (5:1 or less), running at high efficiency while maintaining a reasonable duty cycle. In contrast, a regulator taking a single step from a high input voltage to a 1.xV or 2.xV output must run at a very narrow duty cycle, mandating trade-offs in external component values and compromising efficiency and transient response. The efficiency loss can exceed that of using a 2-step solution (see the 2-Step Efficiency Calculation section and Figure 10). Further complicating the calculation is the fact that many systems draw a significant fraction of their total power off the intermediate 5V supply, bypassing the low voltage supply. 2-step solutions using the LTC1702 usually match or exceed the total system efficiency of single-step solutions, and provide the additional benefits of improved transient response, reduced PCB area and simplified power trace routing. 2-step regulation can buy advantages in thermal management as well. Power dissipation in the LTC1702 portion of a 2-step circuit is lower than it would be in a typical 1-step converter, even in cases where the 1-step converter has higher total efficiency than the 2-step system. In a typical microprocessor core supply regulator, for example, the regulator is usually located right next to the CPU. In a 1-step design, all of the power dissipated by the core regulator is right there next to the hot CPU, aggravating thermal management. In a 2-step LTC1702 design, a significant percentage of the power lost in the core regulation system happens in the 5V supply, which is usually located away from the CPU. The power lost to heat in the LTC1702 section of the system is relatively low, minimizing the added heat near the CPU. See the Optimizing Performance section for a detailed explanation of how to calculate system efficiency. 2-Phase Operation The LTC1702 dual switching regulator controller also features the considerable benefits of 2-phase operation. Notebook computers, hand-held terminals and automotive electronics all benefit from the lower input filtering requirement, reduced electromagnetic interference (EMI) and increased efficiency associated with 2-phase operation. Why the need for 2-phase operation? Up until the LTC1702, constant-frequency dual switching regulators operated both channels in phase (i.e., single-phase operation). This means that both topside MOSFETs turned on at the same time, causing current pulses of up to twice the amplitude of those for one regulator to be drawn from the input capacitor. These large amplitude current pulses increased the total RMS current flowing from the input capacitor, requiring the use of more expensive input capacitors and increasing both EMI and losses in the input capacitor and input power supply. With 2-phase operation, the two channels of the LTC1702 are operated 180 degrees out of phase. This effectively interleaves the current pulses coming from the switches, greatly reducing the overlap time where they add together. The result is a significant reduction in total RMS input current, which in turn allows less expensive input capacitors to be used, reduces shielding requirements for EMI and improves real world operating efficiency. Figure 7 shows example waveforms for a single switching regulator channel versus a 2-phase LTC1702 system with both sides switching. A single-phase dual regulator with both sides operating would exhibit double the single side numbers. In this example, 2-phase operation reduced the RMS input current from 9.3ARMS (2 × 4.66ARMS) to 4.8ARMS. While this is an impressive reduction in itself, 1702fa 8 LTC1702 U W U U APPLICATIONS INFORMATION remember that the power losses are proportional to IRMS2, meaning that the actual power wasted is reduced by a factor of 3.75. The reduced input ripple voltage also means less power is lost in the input power path, which could include batteries, switches, trace/connector resistances and protection circuitry. Improvements in both conducted and radiated EMI also directly accrue as a result of the reduced RMS input current and voltage. Small Footprint The LTC1702 operates at a 550kHz switching frequency, allowing it to use low value inductors without generating excessive ripple currents. Because the inductor stores less energy per cycle, the physical size of the inductor can be reduced without risking core saturation, saving PCB board space. The high operating frequency also means less energy is stored in the output capacitors between cycles, minimizing their required value and size. The remaining components, including the 150mil SSOP-24 LTC1702, are tiny, allowing an entire dual-output LTC1702 circuit to be constructed in 1.5in2 of PCB space. Further, this space is generally located right next to the microprocessor or in some similarly congested area, where PCB real estate is at a premium. The fact that the LTC1702 runs off the 5V supply, often available from a power plane, is an added benefit in portable systems —it does not require a dedicated supply line running from the battery. Fast Transient Response The LTC1702 uses a fast 25MHz GBW op amp as an error amplifier. This allows the compensation network to be designed with several poles and zeros in a more flexible configuration than with a typical gm feedback amplifier. The high bandwidth of the amplifier, coupled with the high switching frequency and the low values of the external inductor and output capacitor, allow very high loop crossover frequencies. The low inductor value is the other half of the equation—with a typical value on the order of 1µH, the inductor allows very fast di/dt slew rates. The result is superior transient response compared with conventional solutions. High Efficiency The LTC1702 uses a synchronous step-down (buck) architecture, with two external N-channel MOSFETs per output. A floating topside driver and a simple external charge pump provide full gate drive to the upper MOSFET. The voltage mode feedback loop and MOSFET VDS current limit sensing remove the need for an external current sense resistor, eliminating an external component and a source of power loss in the high current path. Properly designed circuits using low gate charge MOSFETs are capable of efficiencies exceeding 90% over a wide range of output voltages. ARCHITECTURE DETAILS The LTC1702 dual switching regulator controller includes two identical, independent regulator channels. The two sides of the chip and their corresponding external components act independently of each other with the exception of the common input bypass capacitor and the FCB and FAULT pins, which affect both channels. In the following discussions, when a pin is referred to without mentioning which side is involved, that discussion applies equally to both sides. Switching Architecture Each half of the LTC1702 is designed to operate as a synchronous buck converter (Figure 1). Each channel includes two high power MOSFET gate drivers to control external N-channel MOSFETs QT and QB. These drivers have 0.5Ω output impedances and can carry well over an VIN + CIN TG QT LTC1702 SW PGND BG QB LEXT VOUT + COUT 1702 F01 Figure 1. Synchronous Buck Architecture 1702fa 9 LTC1702 U W U U APPLICATIONS INFORMATION amp of continuous current with peak currents up to 5A to slew large MOSFET gates quickly. The external MOSFETs are connected with the drain of QT attached to the input supply and the source of QT at the switching node SW. QB is the synchronous rectifier with its drain at SW and its source at PGND. SW is connected to one end of the inductor, with the other end connected to VOUT. The output capacitor is connected from VOUT to PGND. When a switching cycle begins, QB is turned off and QT is turned on. SW rises almost immediately to VIN and the inductor current begins to increase. When the PWM pulse finishes, QT turns off and one nonoverlap interval later, QB turns on. Now SW drops to PGND and the inductor current decreases. The cycle repeats with the next tick of the master clock. The percentage of time spent in each mode is controlled by the duty cycle of the PWM signal, which in turn is controlled by the feedback amplifier. The master clock generates a 1VP-P, 550kHz sawtooth waveform and turns QT once every 1.8µs. In a typical application with a 5V input and a 1.6V output, the duty cycle will be set at 1.6/ 5 × 100% or 32% by the feedback loop. This will give roughly a 575ns on-time for QT and a 1.22µs on-time for QB. This constant frequency operation brings with it a couple of benefits. Inductor and capacitor values can be chosen with a precise operating frequency in mind and the feedback loop components can be similarly tightly specified. Noise generated by the circuit will always be in a known frequency band with the 550kHz frequency designed to leave the 455kHz IF band free of interference. Subharmonic oscillation and slope compensation, common headaches with constant frequency current mode switchers, are absent in voltage mode designs like the LTC1702. During the time that QT is on, its source (the SW pin) is at VIN. VIN is also the power supply for the LTC1702. However, QT requires VIN + VGS(ON) at its gate to achieve minimum RON. This presents a problem for the LTC1702— it needs to generate a gate drive signal at TG higher than its highest supply voltage. To get around this, the TG driver runs from floating supplies, with its negative supply attached to SW and its power supply at BOOST. This allows it to slew up and down with the source of QT. In combina- tion with a simple external charge pump (Figure 2), this allows the LTC1702 to completely enhance the gate of QT without requiring an additional, higher supply voltage. The two channels of the LTC1702 run from a common clock, with the phasing chosen to be 180° from side 1 to side 2. This has the effect of doubling the frequency of the switching pulses seen by the input bypass capacitor, significantly lowering the RMS current seen by the capacitor and reducing the value required (see the 2-Phase section). VIN PVCC BOOST TG + DCP CCP 1µF QT LEXT SW BG LTC1702 CIN VOUT + QB COUT PGND 1702 F02 Figure 2. Floating TG Driver Supply Feedback Amplifier Each side of the LTC1702 senses the output voltage at VOUT with an internal feedback op amp (see Block Diagram). This is a real op amp with a low impedance output, 85dB open-loop gain and 25MHz gain-bandwidth product. The positive input is connected internally to an 800mV reference, while the negative input is connected to the FB pin. The output is connected to COMP, which is in turn connected to the soft-start circuitry and from there to the PWM generator. Unlike many regulators that use a resistor divider connected to a high impedance feedback input, the LTC1702 is designed to use an inverting summing amplifier topology with the FB pin configured as a virtual ground. This allows flexibility in choosing pole and zero locations not available with simple gm configurations. In particular, it allows the use of “type 3” compensation, which provides a phase boost at the LC pole frequency and significantly 1702fa 10 LTC1702 U U W U APPLICATIONS INFORMATION improves loop phase margin (see Figure 3). The Feedback Loop/Compensation section contains a detailed explanation of type 3 feedback loops. + COMP 0.8V FB R1 FB – C3 R3 VOUT RB C2 R2 C1 1702 F03 Figure 3. “Type 3” Feedback Loop MIN/MAX Two additional feedback loops keep an eye on the primary feedback amplifier and step in if the feedback node moves ±5% from its nominal 800mV value. The MAX comparator (see Block Diagram) activates whenever FB rises more than 5% above 800mV. It immediately turns the top MOSFET (QT) off and the bottom MOSFET (QB) on and keeps them that way until FB falls back within 5%. This pulls the output down as fast as possible, preventing damage to the (often expensive) load. If FB rises because the output is shorted to a higher supply, QB will stay on until the short goes away, the higher supply current limits or QB dies trying to save the load. This behavior provides maximum protection against overvoltage faults at the output, while allowing the circuit to resume normal operation when the fault is removed. The overvoltage protection circuit can optionally be set to latch the output off permanently (see the Overvoltage Fault section). The MIN comparator (see Block Diagram) trips whenever FB is more than 5% below 800mV and immediately forces the switch duty cycle to 90% to bring the output voltage back into range. It releases when FB is within the 5% window. MIN is disabled when the soft-start or current limit circuits are active—the only two times that the output should legitimately be below its regulated value. Notice that the FB pin is the virtual ground node of the feedback amplifier. A typical compensation network does not include local DC feedback around the amplifier, so that the DC level at FB will be an accurate replica of the output voltage, divided down by R1 and RB (Figure 3). However, the compensation capacitors will tend to attenuate AC signals at FB, especially with low bandwidth type 1 feedback loops. This creates a situation where the MIN and MAX comparators do not respond immediately to shifts in the output voltage, since they monitor the output at FB. Maximizing feedback loop bandwidth will minimize these delays and allow MIN and MAX to operate properly. See the Feedback Loop/Compensation section. PGOOD Flags The MIN comparator performs another function; it drives the external “power good” pin (PGOOD) through a 100µs delay stage. PGOOD is an open-drain output, allowing it to be wire-OR’ed with other open-drain/open-collector signals. An external pull-up resistor is required for PGOOD to swing high. Any time the FB pin is more than 5% below the programmed value for more than 100µs, PGOOD will pull low, indicating that the output is out of regulation. PGOOD remains active during soft-start and current limit, even though the MIN comparator has no effect on the duty cycle during these times. The 100µs delay ensures that short output transient glitches that are successfully “caught” by the MIN comparator don’t cause momentary glitches at the PGOOD pin. Note that the PGOOD pin only watches MIN, not MAX—it does not indicate if the output is 5% above the programmed value. When either side of the LTC1702 is in shutdown, its associated PGOOD pin will go high. This behavior allows a valid PGOOD reading when the two PGOOD pins are tied together, even if one side is shut down. It also reduces quiescent current by eliminating the excess current drawn by the pull-up at the PGOOD pin. As soon as the RUN/SS pin rises above the shutdown threshold and the side comes out of shutdown, the PGOOD pin will pull low until the output voltage is valid. If both sides are shut down at the same time, both PGOOD pins will go high. To avoid confusion, if either side of the LTC1702 is shut down, the host system should ignore the associated PGOOD pin. 1702fa 11 LTC1702 U W U U APPLICATIONS INFORMATION SHUTDOWN/SOFT-START Each half of the LTC1702 has a RUN/SS pin. The RUN/SS pins perform two functions: when pulled to ground, each shuts down its half of the LTC1702, and each acts as a conventional soft-start pin, enforcing a maximum duty cycle limit proportional to the voltage at RUN/SS. An internal 3.5µA current source pull-up is connected to each RUN/SS pin, allowing a soft-start ramp to be generated with a single external capacitor to ground. The 3.5µA current sources are active even when the LTC1702 is shut down, ensuring the device will start when any external pull-down at RUN/SS is released. Either side can be shut down without affecting the operation of the other side. If both sides are shut down at the same time, the LTC1702 goes into a micropower sleep mode, and quiescent current drops below 100µA. Entering sleep mode also resets the FAULT latch, if it was set. Each RUN/SS pin shuts down its half of the LTC1702 when it falls below about 0.5V. Between 0.5V and about 1V, that half is active, but the maximum duty cycle is limited to 10%. The maximum duty cycle limit increases linearly between 1V and 2.5V, reaching its final value of 90% when RUN/SS is above 2.5V. Somewhere before this point, the feedback amplifier will assume control of the loop and the output will come into regulation. When RUN/SS rises to 0.5V below VCC, the MIN feedback comparator is enabled, and the LTC1702 is in full operation (see Figure 4). CURRENT LIMIT The LTC1702 includes an onboard current limit circuit that limits the maximum output current to a user-programmed level. It works by sensing the voltage drop across QB during the time that QB is on and comparing that voltage to a user-programmed voltage at IMAX. Since QB looks like a low value resistor during its on-time, the voltage drop across it is proportional to the current flowing in it. In a buck converter, the average current in the inductor is equal to the output current. This current also flows through QB during its on-time. Thus, by watching the voltage across QB, the LTC1702 can monitor the output current. VOUT 0V 5V 4.5V 2.5V VRUN/SS 2.5V 1.0V 0.55V 0V LTC1702 ENABLED RUN/SS CONTROLS DUTY CYCLE RUN/SS CONTROLS DUTY CYCLE COMP CONTROLS DUTY CYCLE MIN COMPARATOR ENABLED START-UP NORMAL OPERATION CURRENT LIMIT 1702 F04 Figure 4. Soft-Start Operation in Start-Up and Current Limit 1702fa 12 LTC1702 U W U U APPLICATIONS INFORMATION Any time QB is on and the current flowing to the output is reasonably large, the SW node at the drain of QB will be somewhat negative with respect to PGND. The LTC1702 senses this voltage and inverts it to allow it to compare the sensed voltage with a positive voltage at the IMAX pin. The IMAX pin includes a trimmed 10µA pull-up, enabling the user to set the voltage at IMAX with a single resistor, RIMAX, to ground. The LTC1702 compares the two inputs and begins limiting the output current when the magnitude of the negative voltage at the SW pin is greater than the voltage at IMAX. The current limit detector is connected to an internal gm amplifier that pulls a current from the RUN/SS pin proportional to the difference in voltage magnitudes between the SW and IMAX pins. This current begins to discharge the soft-start capacitor at RUN/SS, reducing the duty cycle and controlling the output voltage until the current drops below the limit. The soft-start capacitor needs to move a fair amount before it has any effect on the duty cycle, adding a delay until the current limit takes effect (Figure 4). This allows the LTC1702 to experience brief overload conditions without affecting the output voltage regulation. The delay also acts as a pole in the current limit loop to enhance loop stability. Larger overloads cause the softstart capacitor to pull down quickly, protecting the output components from damage. The current limit gm amplifier includes a clamp to prevent it from pulling RUN/SS below 0.5V and shutting off the device. Power MOSFET RDS(ON) varies from MOSFET to MOSFET, limiting the accuracy obtainable from the LTC1702 current limit loop. Additionally, ringing on the SW node due to parasitics can add to the apparent current, causing the loop to engage early. The LTC1702 current limit is designed primarily as a disaster prevention, “no blow up” circuit, and is not useful as a precision current regulator. It should typically be set around 50% above the maximum expected normal output current to prevent component tolerances from encroaching on the normal current range. See the Current Limit Programming section for advice on choosing a valve for RIMAX. DISCONTINUOUS/Burst Mode OPERATION Theory of operation The LTC1702 switching logic has three modes of operation. Under heavy loads, it operates as a fully synchronous, continuous conduction switching regulator. In this mode of operation (“continuous” mode), the current in the inductor flows in the positive direction (toward the output) during the entire switching cycle, constantly supplying current to the load. In this mode, the synchronous switch (QB) is on whenever QT is off, so the current always flows through a low impedance switch, minimizing voltage drop and power loss. This is the most efficient mode of operation at heavy loads, where the resistive losses in the power devices are the dominant loss term. Continuous mode works efficiently when the load current is greater than half of the ripple current in the inductor. In a buck converter like the LTC1702, the average current in the inductor (averaged over one switching cycle) is equal to the load current. The ripple current is the difference between the maximum and the minimum current during a switching cycle (see Figure 5a). The ripple current depends on inductor value, clock frequency and output voltage, but is constant regardless of load as long as the LTC1702 remains in continuous mode. See the Inductor Selection section for a detailed description of ripple current. As the output load current decreases in continuous mode, the average current in the inductor will reach a point where it drops below half the ripple current. At this point, the inductor current will reverse during a portion of the switching cycle, or begin to flow from the output back to the input. This does not adversely affect regulation, but does cause additional losses as a portion of the inductor current flows back and forth through the resistive power switches, giving away a little more power each time and lowering the efficiency. There are some benefits to allowing this reverse current flow: the circuit will maintain regulation even if the load current drops below zero (the load supplies current to the LTC1702) and the output 1702fa 13 LTC1702 U W U U APPLICATIONS INFORMATION ripple voltage and frequency remain constant at all loads, easing filtering requirements. Circuits that take advantage of this behavior can force the LTC1702 to operate in continuous mode at all loads by tying the FCB (Force Continuous Bar) pin to ground. Discontinuous Mode To minimize the efficiency loss due to reverse current flow at light loads, the LTC1702 switches to a second mode of operation: discontinuous mode (Figure 5b). In discontinuous mode, the LTC1702 detects when the inductor current approaches zero and turns off QB for the remainder of the switch cycle. During this time, the voltage at the SW pin will float about VOUT, the voltage across the inductor will be zero, and the inductor current remains zero until the next switching cycle begins and QT turns on again. This prevents current from flowing backwards in QB, eliminating that power loss term. It also reduces the ripple current in the inductor as the output current approaches zero. The LTC1702 detects that the inductor current has reached zero by monitoring the voltage at the SW pin while QB is INDUCTOR CURRENT IRIPPLE IAVERAGE TIME on. Since QB acts like a resistor, SW should ideally be right at 0V when the inductor current reaches zero. In reality, the SW node will ring to some degree immediately after it is switched to ground by QB, causing some uncertainty as to the actual moment the average current in QB goes to zero. The LTC1702 minimizes this effect by ignoring the SW node for a fixed 50ns after QB turns on when the ringing is most severe, and by including a few millivolts offset in the comparator that monitors the SW node. Despite these precautions, some combinations of inductor and layout parasitics can cause the LTC1702 to enter discontinuous mode erratically. In many cases, the time that QB turns off will correspond to a peak in the ringing waveform at the SW pin (Figure 6). This erratic operation isn’t pretty, but retains much of the efficiency benefit of discontinuous mode and maintains regulation at all times. Burst Mode Operation Discontinuous mode removes the resistive loss drop term in QB, but the LTC1702 is still switching QT and QB on and off once a cycle. Each time an external MOSFET is turned on, the internal driver must charge its gate to VCC. Each time it is turned off, that charge is lost to ground. At the high switching frequencies that the LTC1702 operates at, the charge lost to the gates can add up to tens of milliamps from VCC. As the load current continues to drop, this quickly become the dominant power loss term, reducing efficiency once again. DISCONTINUOUS COMPARATOR TURNS OFF BG 1702 F05a Figure 5a. Continuous Mode VSW INDUCTOR CURRENT 0V TIME 50ns BLANK TIME 5V IRIPPLE VBG 0V TIME 1702 F06 IAVERAGE TIME Figure 5b. Discontinuous Mode 1702 F05b Figure 6. Ringing at SW Causes Discontinuous Comparator to Trip Early 1702fa 14 LTC1702 U W U U APPLICATIONS INFORMATION Once again, the LTC1702 switches to a new mode to minimize efficiency loss: Burst Mode operation. As the circuit goes deeper and deeper into discontinuous mode, the total time QT and QB are on reduces. However, the ratio of the time that QT is on to the time that QB is on must remain constant for the output to stay in regulation. An internal timer circuit forces QT to stay on for at least 10% of a normal switching cycle. When the load drops to the point that the output requires less than 10% on-time at QT, the output voltage will begin to rise. The LTC1702 senses this rise and shuts both QT and QB off completely, skipping several switching cycles until the output falls back into range. It then resumes switching in discontinuous mode with QT at 10% duty cycle and the burst sequence repeats. The total deviation from the regulated output is within the 1% regulation tolerance of the LTC1702. In Burst Mode operation, both resistive loss and switching loss are minimized while keeping the output in regulation. The ripple current will be set by the 10% QT on-time and the input supply voltage and is the lowest of all three operating modes. As the load current falls to zero in Burst Mode operation, the most significant loss term becomes the 3mA quiescent current drawn by each side of the LTC1702—usually much less than the minimum load current in a typical low voltage logic system. Burst Mode operation maximizes efficiency at low load currents, but can cause low frequency ripple in the output voltage as the cycle-skipping circuitry switches on and off. FCB Pin In some circumstances, it is desirable to control or disable discontinuous and Burst Mode operations. The FCB (Force Continuous Bar) pin allows the user to do this. When the FCB pin is high, the LTC1702 is allowed to enter discontinuous and Burst Mode operations at either side as required. If FCB is taken low, discontinuous and Burst Mode operations are disabled and both sides of the LTC1702 run in continuous mode regardless of load. This does not affect output regulation but does reduce efficiency at low output currents. The FCB pin threshold is specified at 0.8V ±50mV, and includes 20mV of hysteresis, allowing it to be used as a precision small-signal comparator. Paralleling Outputs Synchronous regulators (like the LTC1702) are known for their bullheadedness when their outputs are paralleled with other regulators. In particular, a synchronous regulator paralleled with another regulator whose output is slightly higher (perhaps just by millivolts) will happily sink amps of current attempting to pull its own output back down to what it thinks is the right value. The LTC1702 discontinuous mode allows it to be paralleled with another regulator without fighting. A typical system might use the LTC1702 as a primary regulator and a small LDO as a backup regulator to keep SRAM alive when the main power is off. When the LTC1702 is shut down (by pulling RUN/SS to ground), both QT and QB turn off and the output goes into a high impedance state, allowing the smaller regulator to support the output voltage. However, if the LTC1702 is powered back up in continuous mode, it will begin a soft-start cycle with a low duty cycle, pulling the output down and corrupting the data stored in SRAM. The solution is to tie FCB high, allowing the device to start in discontinuous mode. Any reverse current flow in QB will trip the discontinuous mode circuitry, preventing the LTC1702 from pulling down the output. The Typical Applications section shows an example of such a circuit. OVERVOLTAGE FAULT The LTC1702 includes a single overvoltage fault flag for both channels: FAULT. FAULT is an open-drain output with an internal 10µA pull-up. If either FB pin rises more than 15% above the nominal 800mV value for more than 25µs, the overvoltage comparator will trip, setting an internal latch. This latch releases the pull-down at FAULT, allowing the 10µA pull-up to take it high. When FAULT goes high, the LTC1702 stops all switching, turns both QB (bottom synchronous) MOSFETs on continuously and remains in this state until both RUN/SS pins are pulled low simultaneously, the power supply is recycled, or the FAULT pin is pulled low externally. This behavior is intended to protect a potentially expensive load from overvoltage damage at all costs. Under some conditions, this behavior can cause the output voltage to undershoot 1702fa 15 LTC1702 U W U U APPLICATIONS INFORMATION below ground. If latched FAULT mode is used, a Schottky diode should be added with its cathode at the output and its anode at ground to clamp the negative voltage to a safe level and prevent possible damage to the load and the output capacitors. Note that in overvoltage conditions, the MAX comparator will kick in at just +5%, turning QB on continuously long before the output reaches +15%. Under most fault conditions, this is adequate to bring the output back down without firing the fault latch. Additionally, if MAX successfully keeps the output below +15%, the LTC1702 will resume normal regulation as soon as the output overvoltage fault is resolved. In some circuits, the OV latch can be a liability. Consider a circuit where the output voltage at one channel may be changed on the fly by switching in different feedback resistors. A downward adjustment of greater than 15% will fire the fault latch, disabling both sides of the LTC1702 until the power is recycled. In circuits such as this, the fault latch can be disabled by grounding the FAULT pin. The internal latch will still be set the first time the output exceeds +15%, but the 10µA current source pull-up will not be able to pull FAULT high, and the LTC1702 will ignore the latch and continue normal operation. The MAX comparator will act as usual, turning on QB until output is within range and then allowing the loop to resume normal operation. FAULT can also be pulled down with external open-collector logic to restart a fault-latched LTC1702 as an alternative to recycling the power. Note that this will not reset the internal latch; if the external pull-down is released, the LTC1702 will reenter FAULT mode. To reset the latch, pull both RUN/SS pins low simultaneously or cycle the input power. EXTERNAL COMPONENT SELECTION low RDS(ON) at 5V VGS (3.3V VGS if the PVCC input supply is 3.3V) to minimize resistive power loss while they are conducting current. They must also have low gate charge to minimize transition losses during switching. On the other hand, voltage breakdown requirements in a typical LTC1702 circuit are pretty tame: the 7V maximum input voltage limits the VDS and VGS the MOSFETs can see to safe levels for most devices. Low RDS(ON) RDS(ON) calculations are pretty straightforward. RDS(ON) is the resistance from the drain to the source of the MOSFET when the gate is fully on. Many MOSFETs have RDS(ON) specified at 4.5V gate drive—this is the right number to use in LTC1702 circuits running from a 5V supply. As current flows through this resistance while the MOSFET is on, it generates I2R watts of heat, where I is the current flowing (usually equal to the output current) and R is the MOSFET RDS(ON). This heat is only generated when the MOSFET is on. When it is off, the current is zero and the power lost is also zero (and the other MOSFET is busy losing power). This lost power does two things: it subtracts from the power available at the output, costing efficiency, and it makes the MOSFET hotter—both bad things. The effect is worst at maximum load when the current in the MOSFETs and thus the power lost are at a maximum. Lowering RDS(ON) improves heavy load efficiency at the expense of additional gate charge (usually) and more cost (usually). Proper choice of MOSFET RDS(ON) becomes a trade-off between tolerable efficiency loss, power dissipation and cost. Note that while the lost power has a significant effect on system efficiency, it only adds up to a watt or two in a typical LTC1702 circuit, allowing the use of small, surface mount MOSFETs without heat sinks. POWER MOSFETs Gate Charge Getting peak efficiency out of the LTC1702 depends strongly on the external MOSFETs used. The LTC1702 requires at least two external MOSFETs per side—more if one or more of the MOSFETs are paralleled to lower on-resistance. To work efficiently, these MOSFETs must exhibit Gate charge is amount of charge (essentially, the number of electrons) that the LTC1702 needs to put into the gate of an external MOSFET to turn it on. The easiest way to visualize gate charge is to think of it as a capacitance from the gate pin of the MOSFET to SW (for QT) or to PGND (for 1702fa 16 LTC1702 U W U U APPLICATIONS INFORMATION QB). This capacitance is composed of MOSFET channel charge, actual parasitic drain-source capacitance and Miller-multiplied gate-drain capacitance, but can be approximated as a single capacitance from gate to source. Regardless of where the charge is going, the fact remains that it all has to come out of VCC to turn the MOSFET gate on, and when the MOSFET is turned back off, that charge all ends up at ground. In the meanwhile, it travels through the LTC1702’s gate drivers, heating them up. More power lost! In this case, the power is lost in little bite-sized chunks, one chunk per switch per cycle, with the size of the chunk set by the gate charge of the MOSFET. Every time the MOSFET switches, another chunk is lost. Clearly, the faster the clock runs, the more important gate charge becomes as a loss term. Old-fashioned switchers that ran at 20kHz could pretty much ignore gate charge as a loss term; in the 550kHz LTC1702, gate charge loss can be a significant efficiency penalty. Gate charge loss can be the dominant loss term at medium load currents, especially with large MOSFETs. Gate charge loss is also the primary cause of power dissipation in the LTC1702 itself. times that of the total input capacitance of the topside MOSFET(s). For very large external MOSFETs (or multiple MOSFETs in parallel), CCP may need to be increased over the 1µF value. INPUT SUPPLY The BiCMOS process that allows the LTC1702 to include large MOSFET drivers on-chip also limits the maximum input voltage to 7V. This limits the practical maximum input supply to a loosely regulated 5V or 6V rail. The LTC1702 will operate properly with input supplies down to about 3V, so a typical 3.3V supply can also be used if the external MOSFETs are chosen appropriately (see the Power MOSFETs section). At the same time, the input supply needs to supply several amps of current without excessive voltage drop. The input supply must have regulation adequate to prevent sudden load changes from causing the LTC1702 input voltage to dip. In most typical applications where the LTC1702 is generating a secondary low voltage logic supply, all of these input conditions are met by the main system logic supply when fortified with an input bypass capacitor. TG Charge Pump There’s another nuance of MOSFET drive that the LTC1702 needs to get around. The LTC1702 is designed to use N-channel MOSFETs for both QT and QB, primarily because N-channel MOSFETs generally cost less and have lower RDS(ON) than similar P-channel MOSFETs. Turning QB on is no big deal since the source of QB is attached to PGND; the LTC1702 just switches the BG pin between PGND and VCC. Driving QT is another matter. The source of QT is connected to SW which rises to VCC when QT is on. To keep QT on, the LTC1702 must get TG one MOSFET VGS(ON) above VCC. It does this by utilizing a floating driver with the negative lead of the driver attached to SW (the source of QT) and the VCC lead of the driver coming out separately at BOOST. An external 1µF capacitor CCP connected between SW and BOOST (Figure 2) supplies power to BOOST when SW is high, and recharges itself through DCP when SW is low. This simple charge pump keeps the TG driver alive even as it swings well above VCC. The value of the bootstrap capacitor CCP needs to be at least 100 Input Bypass A typical LTC1702 circuit running from a 5V logic supply might provide 1.6V at 10A at one of its outputs. 5V to 1.6V implies a duty cycle of 32%, which means QT is on 32% of each switching cycle. During QT’s on-time, the current drawn from the input equals the load current and during the rest of the cycle, the current drawn from the input is near zero. This 0A to 10A, 32% duty cycle pulse train adds up to 4.7ARMS at the input. At 550kHz, switching cycles last about 1.8µs—most system logic supplies have no hope of regulating output current with that kind of speed. A local input bypass capacitor is required to make up the difference and prevent the input supply from dropping drastically when QT kicks on. This capacitor is usually chosen for RMS ripple current capability and ESR as well as value. The input bypass capacitor in an LTC1702 circuit is common to both channels. Consider our 10A example case with the other side of the LTC1702 disabled. The input 1702fa 17 LTC1702 U W U U APPLICATIONS INFORMATION bypass capacitor gets exercised in three ways: its ESR must be low enough to keep the initial drop as QT turns on within reason (100mV or so); its RMS current capability must be adequate to withstand the 4.6ARMS ripple current at the input and the capacitance must be large enough to maintain the input voltage until the input supply can make up the difference. Generally, a capacitor that meets the first two parameters will have far more capacitance than is required to keep capacitance-based droop under control. In our example, we need 0.01Ω ESR to keep the input drop under 100mV with a 10A current step and 4.6ARMS ripple current capacity to avoid overheating the capacitor. These requirements can be met with multiple low ESR tantalum or electrolytic capacitors in parallel, or with a large monolithic ceramic capacitor. The two sides of the LTC1702 run off a single master clock and are wired 180° out of phase with each other to significantly reduce the total capacitance/ESR needed at the input. Assuming 100mV of ripple and 10A output current, we needed an ESR of 0.01Ω and 4.7A ripple current capability for one side. Now, assume both sides are running simultaneously with identical loading. If the two sides switched in phase, all the loading conditions would double and we’d need enough capacitance for 9.4ARMS and 0.005Ω ESR. With the two sides out of phase, the input current is 4.8ARMS—barely larger than 32% 10A 68% Q1 CURRENT, SIDE 1 ONLY (FOR 1-PHASE, 2 SIDES: MULTIPLY CURRENT BY 2) 0 Calculating RMS Current in CIN A buck regulator like the LTC1702 draws pulses of current from the input capacitor during normal operation. The input capacitor sees this as AC current, and dissipates power proportional to the RMS value of the input current waveform. To properly specify the capacitor, we need to know the RMS value of the input current. Calculating the approximate RMS value of a pulse train with a fixed duty cycle is straightforward, but the LTC1702 complicates matters by running two sides simultaneously and out of phase, creating a complex waveform at the input. To calculate the approximate RMS value of the input current, we first need to calculate the average DC value with both sides of the LTC1702 operating at maximum load. Over a single period, the system will spend some time with one top switch on and the other off, perhaps some time with both switches on, and perhaps some time with both switches off. During the time each top switch is on, the current will equal that side’s full load output current. When both switches are on, the total current will be the sum of the two full load currents, and when both are off, the current is effectively zero. Multiply each current value by the percentage of the period that the current condition lasts, and sum the results—this is the average DC current value. As an example, consider a circuit that takes a 5V input and generates 3.3V at 3A at side 1 and 1.6V at 10A at side 2. When a cycle starts, TG1 turns on and 3A flows 32% 0 –3.2A 68% 32% 18% 32% 18% 10A Q11 CURRENT Q21 CURRENT BOTH SIDES EQUAL LOAD 2-PHASE OPERATION 0 50% CURRENT IN CIN, SIDE 1 ONLY ICIN = 4.66ARMS, (1-PHASE, 2 SIDES: ICIN = 9.3ARMS) 16% 16% 18% 13 INPUT CURRENT (A) 6.8A 10 IAVE 5.2 3 32% 18% 32% 18% 3.6A 0 CURRENT IN CIN, BOTH SIDES EQUAL LOAD ICIN = 4.8ARMS 0 0 1702 F07 –6.4A A B TIME C D 1702 SB1 Figure 7. RMS Input Current Figure SB1. Average Current Calculation 1702fa 18 LTC1702 U U W U APPLICATIONS INFORMATION from CIN (time point A). 50% of the way through, TG2 turns on and the total current is 13A (time point B). Shortly thereafter, TG1 turns off and the current drops to 10A (time point C). Finally, TG2 turns off and the current spends a short time at 0 before TG1 turns on again (time point D). ( ) ( ) (10A • 0.16) + (0A • 0.18) = 5.18A IAVG = 3A • 0.5 + 13A • 0.16 + Now we can calculate the RMS current. Using the same waveform we used to calculate the average DC current, subtract the average current from each of the DC values. Square each current term and multiply the squares by the same period percentages we used to calculate the average DC current. Sum the results and take the square root. The result is the approximate RMS current as seen by the input capacitor with both sides of the LTC1702 at full load. Actual RMS current will differ due to inductor ripple current and resistive losses, but this approximate value is adequate for input capacitor calculation purposes. 50% 2 IRMS = 2 2 2 = 4.55ARMS If the circuit is likely to spend time with one side operating and the other side shut down, the RMS current will need to be calculated for each possible case (side 1 on, side 2 off; side 1 off, side 2 on; both sides on). The capacitor must be sized to withstand the largest RMS current of the three—sometimes this occurs with one side shut down! Side 1 only: ( ) ( ) IAVE1 = 3A • 0.67 + 0 A • 0.33 = 2.01A IRMS1 = (1 • 0.67) + (–2 • 0.33) = 1.42A 2 2 Side 2 only: ( ) ( RMS ) IAVE2 = 10 A • 0.32 + 0 A • 0.68 = 3.2A IRMS2 = 16% 16% 18% 7.8 AC INPUT CURRENT (A) (–2.18 • 0.5) + (7.82 • 0.16) + (4.82 • 0.16) + (–5.18 • 0.18) (6.8 • 0.32) + (–3.2 • 0.68) 2 2 = 4.66 ARMS > 4.55ARMS 4.8 0 –2.2 – 5.2 0 A B TIME C D 1702 SB2 Figure SB2. AC Current Calculation the single case (Figure 7)! The peak current deltas are still only 10A, requiring the same 0.01Ω ESR rating. As long as the capacitor we chose for the single side application can support the slightly higher 4.8ARMS current, we can add the second channel without changing the input capacitor at all. As a general rule, an input bypass capacitor capable of supporting the larger output current channel can support both channels running simultaneously (see the 2-Phase Operation section for more details). Consider the case where both sides are operating at the same load, with a 50% duty cycle at each side. The RMS current with both sides running is near zero, while the RMS current with one side active is 1/2 the total load current of that side. The 2-phase, 5V to 2.5V circuit in the applications section takes advantage of this phenomenon, allowing it to supply 40A of output current with only 120µF of input capacitance (and only 40µF of output capacitance!). Tantalum capacitors are a popular choice as input capacitors for LTC1702 applications, but they deserve a special caution here. Generic tantalum capacitors have a destructive failure mechanism when they are subjected to large RMS currents (like those seen at the input of a LTC1702). At some random time after they are turned on, they can blow up for no apparent reason. The capacitor manufacturers are aware of this and sell special “surge tested” 1702fa 19 LTC1702 U W U U APPLICATIONS INFORMATION tantalum capacitors specifically designed for use with switching regulators. When choosing a tantalum input capacitor, make sure that it is rated to carry the RMS current that the LTC1702 will draw. If the data sheet doesn’t give an RMS current rating, chances are the capacitor isn’t surge tested. Don’t use it! OUTPUT BYPASS CAPACITOR The output bypass capacitor has quite different requirements from the input capacitor. The ripple current at the output of a buck regulator like the LTC1702 is much lower than at the input, due to the fact that the inductor current is constantly flowing at the output whenever the LTC1702 is operating in continuous mode. The primary concern at the output is capacitor ESR. Fast load current transitions at the output will appear as voltage across the ESR of the output bypass capacitor until the feedback loop in the LTC1702 can change the inductor current to match the new load current value. This ESR step at the output is often the single largest budget item in the load regulation calculation. As an example, our hypothetical 1.6V, 10A switcher with a 0.01Ω ESR output capacitor would experience a 100mV step at the output with a 0 to 10A load step—a 6.3% output change! Usually the solution is to parallel several capacitors at the output. For example, to keep the transient response inside of 3% with the previous design, we’d need an output ESR better than 0.0048Ω. This can be met with three 0.014Ω, 470µF low ESR tantalum capacitors in parallel. INDUCTOR The inductor in a typical LTC1702 circuit is chosen primarily for value and saturation current. The inductor value sets the ripple current, which is commonly chosen at around 40% of the anticipated full load current. Ripple current is set by: tON(Q2) (VOUT ) IRIPPLE = L In our hypothetical 1.6V, 10A example, we'd set the ripple current to 40% of 10A or 4A, and the inductor value would be: tON(Q2) (VOUT ) (1.2µs)(1.6V ) = = 0.5µH IRIPPLE 4A ⎛ 1.6V ⎞ with tON(Q2) = ⎜ 1 − ⎟ / 550kHz = 1.2µs ⎝ 5V ⎠ L= The inductor must not saturate at the expected peak current. In this case, if the current limit was set to 15A, the inductor should be rated to withstand 15A + 1/2 IRIPPLE, or 17A without saturating. FEEDBACK LOOP/COMPENSATION1 Feedback Loop Types In a typical LTC1702 circuit, the feedback loop consists of the modulator, the external inductor and output capacitor, and the feedback amplifier and its compensation network. All of these components affect loop behavior and need to be accounted for in the loop compensation. The modulator consists of the internal PWM generator, the output MOSFET drivers and the external MOSFETs themselves. From a feedback loop point of view, it looks like a linear voltage transfer function from COMP to SW and has a gain roughly equal to the input voltage. It has fairly benign AC behavior at typical loop compensation frequencies with significant phase shift appearing at half the switching frequency. The external inductor/output capacitor combination makes a more significant contribution to loop behavior. These components cause a second order LC roll-off at the output, with the attendant 180° phase shift. This roll-off is what filters the PWM waveform, resulting in the desired DC output voltage, but the phase shift complicates the loop compensation if the gain is still higher than unity at the pole frequency. Eventually (usually well above the LC pole frequency), the reactance of the output capacitor will approach its ESR, and the roll-off due to the capacitor will stop, leaving 6dB/octave and 90° of phase shift (Figure 8). So far, the AC response of the loop is pretty well out of the user’s control. The modulator is a fundamental piece of the LTC1702 design, and the external L and C are usually chosen based on the regulation and load current requirements without considering the AC loop response. The 1The information in this section is based on the paper “The K Factor: A New Mathematical Tool for Stability Analysis and Synthesis” by H. Dean Venable, Venable Industries, Inc. For complete paper, see “Reference Reading #4” at www.linear-tech.com. 1702fa 20 LTC1702 U U W U APPLICATIONS INFORMATION feedback amplifier, on the other hand, gives us a handle with which to adjust the AC response. The goal is to have 180° phase shift at DC (so the loop regulates) and something less than 360° phase shift at the point that the loop gain falls to 0dB. The simplest strategy is to set up the feedback amplifier as an inverting integrator, with the 0dB frequency lower than the LC pole (Figure 9). This “type 1” GAIN (dB) PHASE (DEG) GAIN AV –12dB/OCT 0 0 –90 PHASE –180 –6dB/OCT configuration is stable but transient response will be less than exceptional if the LC pole is at a low frequency. Figure 10 shows an improved “type 2” circuit that uses an additional pole-zero pair to temporarily remove 90° of phase shift. This allows the loop to remain stable with 90° more phase shift in the LC section, provided the loop reaches 0dB gain near the center of the phase “bump.” Type 2 loops work well in systems where the ESR zero in the LC roll-off happens close to the LC pole, limiting the total phase shift due to the LC. The additional phase compensation in the feedback amplifier allows the 0dB point to be at or above the LC pole frequency, improving loop bandwidth substantially over a simple type 1 loop. It has limited ability to compensate for LC combinations where low capacitor ESR keeps the phase shift near 180° for an extended frequency range. LTC1702 circuits using conventional switching grade electrolytic output capacitors can often get acceptable phase margin with type 2 compensation. 1702 F08 C2 Figure 8. Transfer Function of Buck Modulator R2 C1 R1 – IN R1 – IN + RB OUT + RB OUT C1 VREF VREF 1702 F10a 1702 F09a Figure 9a. Type 1 Amplifier Schematic Diagram GAIN (dB) PHASE (DEG) Figure 10a. Type 2 Amplifier Schematic Diagram PHASE (DEG) GAIN (dB) –6dB/OCT GAIN GAIN 0 0 0 0 –6dB/OCT –6dB/OCT –90 –90 –180 –180 PHASE PHASE –270 –270 1702 F10b 1702 F09b Figure 9b. Type 1 Amplifier Transfer Function Figure 10b. Type 2 Amplifier Transfer Function 1702fa 21 LTC1702 U U W U APPLICATIONS INFORMATION “Type 3” loops (Figure 11) use two poles and two zeros to obtain a 180° phase boost in the middle of the frequency band. A properly designed type 3 circuit can maintain acceptable loop stability even when low output capacitor ESR causes the LC section to approach 180° phase shift well above the initial LC roll-off. As with a type 2 circuit, the loop should cross through 0dB in the middle of the phase bump to maximize phase margin. Many LTC1702 circuits using low ESR tantalum or OS-CON output capacitors need type 3 compensation to obtain acceptable phase margin with a high bandwidth feedback loop. C2 C3 R3 R2 R1 C1 – IN OUT + RB VREF 1702 F11a Figure 11a. Type 3 Amplifier Schematic Diagram GAIN (dB) PHASE (DEG) –6dB/OCT +6dB/OCT GAIN 0 –6dB/OCT 0 –90 Applications that require optimized transient response will need to recalculate the compensation values specifically for the circuit in question. The underlying mathematics are complex, but the component values can be calculated in a straightforward manner if we know the gain and phase of the modulator at the crossover frequency. Modulator gain and phase can be measured directly from a breadboard, or can be simulated if the appropriate parasitic values are known. Measurement will give more accurate results, but simulation can often get close enough to give a working system. To measure the modulator gain and phase directly, wire up a breadboard with an LTC1702 and the actual MOSFETs, inductor, and input and output capacitors that the final design will use. This breadboard should use appropriate construction techniques for high speed analog circuitry: bypass capacitors located close to the LTC1702, no long wires connecting components, appropriately sized ground returns, etc. Wire the feedback amplifier as a simple type 1 loop, with a 10k resistor from VOUT to FB and a 0.1µF feedback capacitor from COMP to FB. Choose the bias resistor (RB) as required to set the desired output voltage. Disconnect RB from ground and connect it to a signal generator or to the source output of a network analyzer (Figure 12) to inject a test signal into the loop. Measure the gain and phase from the COMP pin to the output node at the positive terminal of the output capacitor. Make sure the analyzer’s input is AC coupled so that the DC voltages present at both the COMP and VOUT 5V –180 PHASE 10Ω –270 MBR0530T + CIN + 10µF VCC 1702 F11b PVCC BOOST2 Figure 11B. Type 3 Amplifier Transfer Function VCOMP TO ANALYZER 0.1µF Feedback Component Selection Selecting the R and C values for a typical type 2 or type 3 loop is a nontrivial task. The applications shown in this data sheet show typical values, optimized for the power components shown. They should give acceptable performance with similar power components, but can be way off if even one major power component is changed significantly. NC AC SOURCE FROM ANALYZER RB 10k TG 1/2 LTC1702 COMP SW QT FB QB RUN/SS BG 1µF LEXT + VOUT TO ANALYZER COUT FCB FAULT SGND PGND 1702 F12 Figure 12. Modulator Gain/Phase Measurement Set-Up 1702fa 22 LTC1702 U W U U APPLICATIONS INFORMATION nodes don’t corrupt the measurements or damage the analyzer. Finally, choose a convenient resistor value for R1 (10k is usually a good value). Now calculate the remaining values: If breadboard measurement is not practical, a SPICE simulation can be used to generate approximate gain/ phase curves. Plug the expected capacitor, inductor and MOSFET values into the following SPICE deck and generate an AC plot of V(VOUT)/V(COMP) in dB and phase of V(OUT) in degrees. Refer to your SPICE manual for details of how to generate this plot. (K is a constant used in the calculations) *1702 modulator gain/phase *©1999 Linear Technology *this file written to run with PSpice 8.0 *may require modifications for other SPICE simulators ƒ = chosen crossover frequency G = 10(GAIN/20) (this converts GAIN in dB to G in absolute gain) Type 2 Loop: ⎞ ⎛ BOOST K = Tan⎜ + 45°⎟ ⎠ ⎝ 2 1 C2 = 2πƒGKR1 ( ) *MOSFETs rfet mod sw 0.02 ;MOSFET rdson C1 = C2 K2 – 1 *inductor lext sw out1 1u rl out1 out 0.005 ;inductor value ;inductor series R R2 = *output cap cout out out2 1000u resr out2 0 0.01 ;capacitor value ;capacitor ESR *1702 internals emod mod 0 comp 0 5 vstim comp 0 0 ac 1 .ac dec 100 1k 1meg .probe .end ;3.3 for 3.3V supply ;ac stimulus With the gain/phase plot in hand, a loop crossover frequency can be chosen. Usually the curves look something like Figure 8. Choose the crossover frequency in the rising or flat parts of the phase curve, beyond the external LC poles. Frequencies between 10kHz and 50kHz usually work well. Note the gain (GAIN, in dB) and phase (PHASE, in degrees) at this point. The desired feedback amplifier gain will be – GAIN to make the loop gain 0dB at this frequency. Now calculate the needed phase boost, assuming 60° as a target phase margin: BOOST = – (PHASE + 30°) If the required BOOST is less than 60°, a type 2 loop can be used successfully, saving two external components. BOOST values greater than 60° usually require type 3 loops for satisfactory performance. RB = K 2πƒC1 VREF R1 ( ) VOUT – VREF Type 3 Loop: ⎞ ⎛ BOOST K = Tan2 ⎜ + 45°⎟ ⎠ ⎝ 4 1 C2 = 2πƒGR1 C1 = C2 K – 1 ( ) R2 = K 2πƒC1 R1 R3 = (K – 1) C3 = 1 RB = 2πƒ K R3 ( ) VREF R1 VOUT – VREF 1702fa 23 LTC1702 U W U U APPLICATIONS INFORMATION CURRENT LIMIT PROGRAMMING Accuracy Trade-Offs Programming the current limit on the LTC1702 is straightforward. The IMAX pin sets the current limit by setting the maximum allowable voltage drop across QB (the bottom MOSFET) before the current limit circuit engages. The voltage across QB is set by its on-resistance and the current flowing in the inductor, which is the same as the output current. The LTC1702 current limit circuit inverts the voltage at IMAX before comparing it with the negative voltage across QB, allowing the current limit to be set with a positive voltage. The VDS sensing scheme used in the LTC1702 is not particularly accurate, primarily due to uncertainty in the RDS(ON) from MOSFET to MOSFET. A second error term arises from the ringing present at the SW pin, which causes the VDS to look larger than (ILOAD)(RDS(ON)) at the beginning of QB’s on-time. These inaccuracies do not prevent the LTC1702 current limit circuit from protecting itself and the load from damaging overcurrent conditions, but they do prevent the user from setting the current limit to a tight tolerance if more than one copy of the circuit is being built. The 50% factor in the current setting equation above reflects the margin necessary to ensure that the circuit will stay out of current limit at the maximum normal load, even with a hot MOSFET that is running quite a bit higher than its RDS(ON) spec. To set the current limit, calculate the expected voltage drop across QB at the maximum desired current: ( ) VPROG = (IILIM) RDS(ON) + CF ILIM should be chosen to be quite a bit higher than the expected operating current, to allow for MOSFET RDS(ON) changes with temperature. Setting ILIM to 150% of the maximum normal operating current is usually safe and will adequately protect the power components if they are chosen properly. The CF term is an approximate factor that corrects for errors caused by ringing on the switch node (illustrated in Figure 6). This correction factor will change depending on the layout and the components used, but 100mV is usually a good starting point. To provide adequate margin and to accommodate for offsets and external variations, it is recommended that VPROG be calculated with CF = 100 ± 50mV. VPROG is then programmed at the IMAX pin using the internal 10µA pull-up and an external resistor: RILIM = VPROG/10µA The resulting value of RILIM should be checked in an actual circuit to ensure that the ILIM circuit kicks in as expected. MOSFET RDS(ON) specs are like horsepower ratings in automobiles, and should be taken with a grain of salt. Circuits that use very low values for RIMAX (< 20k) should be checked carefully, since small changes in RIMAX can cause large ILIM changes when the 100mV correction factor makes up a large percentage of the total VPROG value. If VPROG is set too low, the LTC1702 may fail to start up. FCB OPERATION/SECONDARY WINDINGS The FCB pin can be used in conjunction with a secondary winding on one side of the LTC1702 to generate a third regulated voltage output. This output can be directly regulated at the FCB pin. In theory, a fourth output could be added, either unregulated or with additional external circuitry at the FCB pin. The extra auxiliary output is taken from a second winding on the core of the inductor on one channel, converting it into a transformer (Figure 13). The auxiliary output voltage is set by the main output voltage and the turns ratio of the extra winding to the primary winding. Load regulation at the auxiliary output will be relatively good as long as the main output is running in continuous mode. As the load on the main channel drops and the LTC1702 switches to discontinuous or Burst Mode operation, the auxiliary output will not be able to maintain regulation, especially if the load at the auxiliary output remains heavy. To avoid this, the auxiliary output voltage can be divided down with a conventional feedback resistor string with the divided auxiliary output voltage fed back to the FCB pin (Figure 13). The FCB pin threshold is trimmed to 800mV 1702fa 24 LTC1702 U W U U APPLICATIONS INFORMATION VIN VOUT(AUX) + + CIN TG COUT(AUX) QT LTC1702 FCB BG + QB VOUT COUT RFCB1 RFCB2 1702 F08 Figure 13. Regulating an Auxiliary Output with the FCB Pin with 10mV of hysteresis, allowing fairly precise control of the auxiliary voltage. If the LTC1702 is in discontinuous or Burst Mode operation and the auxiliary output voltage drops, the FCB pin will trip and the LTC1702 will resume continuous operation regardless of the load on the main output. The FCB pin removes the requirement that power must be drawn from the inductor primary in order to extract power from the auxiliary windings. With the loop in continuous mode, the auxiliary outputs may be loaded without regard to the primary load. Note that if the LTC1702 is already running in continuous mode and the auxiliary output drops due to excessive loading, no additional action can be taken by the LTC1702 to regulate the auxiliary output. POWER GOOD/FAULT FLAGS The PGOOD pins report the status of the output voltage at their respective outputs. Each is an open-drain output that pulls low until the FB pin rises to (VREF – 5%), indicating that the output voltage has risen to within 5% of the programmed output voltage. Each PGOOD pin can interface directly to standard logic inputs if an appropriate pullup resistor is added, or the two pins can be tied together with a single pull-up to give a “both good” signal. Each PGOOD pin includes an internal 100µs delay to prevent glitches at the output from indicating false PGOOD signals. The FAULT pin is an additional open-drain output that indicates if one or both of the outputs has exceeded 15% of its programmed output voltage. FAULT includes an internal 10µA pull-up to VCC and does not require an external pull-up to interface to standard logic. FAULT pulls low in normal operation, and releases when a overvoltage fault is detected. When an overvoltage fault occurs, an internal latch sets and FAULT goes high, disabling the LTC1702 until the latch is cleared by recycling the power or pulling both RUN/SS pins low simultaneously. Alternately, the FAULT pin can be pulled back low externally with an opencollector/open-drain device or an NFET or NPN, which will allow the LTC1702 to resume normal operation, but will not reset the latch. If the pull-down is later removed, the LTC1702 will latch off again unless the latch is reset by cycling the power or RUN/SS pins. Note that both the PGOOD pins and the FAULT pin monitor the output voltages by watching the FB pins. During normal operation, each FB pin is held at a virtual ground by the feedback amplifier, and changes at the output will not appear at FB. This is not an issue with a properly designed circuit, since the virtual ground at FB implies that the output voltage is under control. If the feedback amplifier loses control of the output, the virtual ground disappears and the PGOOD circuit can see any output changes. This occurs whenever the soft-start or current limit circuits are active, whenever the MIN or MAX comparators are active, or any time the feedback amplifier output (the COMP pin) hits a rail or is in slew limit. Since the MAX comparator will engage well before the output reaches the +15% fault level, the FAULT output is largely unaffected by the virtual ground at FB. OPTIMIZING PERFORMANCE 2-Step Conversion The LTC1702 is ideally suited for use in 2-step conversion systems. 2-step systems use a primary regulator to convert the input power source (batteries or AC line voltage) 1702fa 25 LTC1702 U U W U APPLICATIONS INFORMATION to an intermediate supply voltage, often 5V. The LTC1702 then converts the intermediate voltage to the low voltage, high current supplies required by the system. Compared to a 1-step converter that converts a high input voltage directly to a very low output voltage, the 2-step converter exhibits superior transient response, smaller component size and equivalent efficiency. Thermal management and layout complexity are also improved with a 2-step approach. A typical notebook computer supply might use a 4-cell Li-Ion battery pack as an input supply with a 15V nominal terminal voltage. The logic circuits require 5V/3A and 3.3V/ 5A to power system board logic, and 2.5V/0.5A, 1.8V/2A and 1.5V/10A to power the CPU. A typical 2-step conversion system would use a step-down switcher (perhaps an LTC1628 or two LTC1625s) to convert 15V to 5V and another to convert 15V to 3.3V (Figure 14). One channel of the LTC1702 would generate the 1.5V supply using the 3.3V supply as the input and the other channel would generate 1.8V using the 5V supply as the input. The corresponding 1-step system would use four similar step-down switchers, each using 15V as the input supply and generating one of the four output voltages. Since the 2.5V supply represents a small fraction of the total output power, either system can generate it from the 3.3V output using an LDO linear regulator, without the 75% linear efficiency making much of an impact on total system efficiency. VBAT 15V 5V/3A LTC1628* LTC1702 1.8V/2A 1.5V/10A 3.3V/5A *OR TWO LTC1625s LDO 2.5V/0.5A 1702 F14 Figure 14. 2-Step Conversion Block Diagram Clearly, the 5V and 3.3V sections of the two schemes are equivalent. The 2-step system draws additional power from the 5V and 3.3V outputs, but the regulation techniques and trade-offs at these outputs are similar. The difference lies in the way the 1.8V and 1.5V supplies are generated. For example, the 2-step system converts 3.3V to 1.5V with a 45% duty cycle. During the QT on-time, the voltage across the inductor is 1.8V and during the QB on-time, the voltage is 1.5V, giving roughly symmetrical transient response to positive and negative load steps. The 1.8V maximum voltage across the inductor allows the use of a small 0.47µH inductor while keeping ripple current under 4A (40% of the 10A maximum load). By contrast, the 1-step converter is converting 15V to 1.5V, requiring just a 10% duty cycle. Inductor voltages are now 13.5V when QT is on and 1.5V when QB is on, giving vastly different di/dt values and correspondingly skewed transient response with positive and negative current steps. The narrow 10% duty cycle usually requires a lower switching frequency, which in turn requires a higher value inductor and larger output capacitor. Parasitic losses due to the large voltage swing at the source of QT cost efficiency, eliminating any advantage the 1-step conversion might have had. Note that power dissipation in the LTC1702 portion of a 2-step circuit is lower than it would be in a typical 1-step converter, even in cases where the 1-step converter has higher total efficiency than the 2-step system. In a typical microprocessor core supply regulator, for example, the regulator is usually located right next to the CPU. In a 1-step design, all of the power dissipated by the core regulator is right there next to the hot CPU, aggravating thermal management. In a 2-step LTC1702 design, a significant percentage of the power lost in the core regulation system happens in the 5V or 3.3V supply, which is usually away from the CPU. The power lost to heat in the LTC1702 section of the system is relatively low, minimizing the heat near the CPU. 1702fa 26 LTC1702 U W U U APPLICATIONS INFORMATION 2-Step Efficiency Calculation Maximizing High Load Current Efficiency Calculating the efficiency of a 2-step converter system involves some subtleties. Simply multiplying the efficiency of the primary 5V or 3.3V supply by the efficiency of the 1.8V or 1.5V supply underestimates the actual efficiency, since a significant fraction of the total power is drawn from the 3.3V and 5V rails in a typical system. The correct way to calculate system efficiency is to calculate the power lost in each stage of the converter, and divide the total output power from all outputs by the sum of the output power plus the power lost: Efficiency = Efficiency at high load currents (when the LTC1702 is operating in continuous mode) is primarily controlled by the resistance of the components in the power path (QT, QB, LEXT) and power lost in the gate drive circuits due to MOSFET gate charge. Maximizing efficiency in this region of operation is as simple as minimizing these terms. In our example 2-step system, the total output power is: Total output power = 15W + 16.5W + 1.25W + 3.6W + 15W = 51.35W corresponding to 5V, 3.3V, 2.5V, 1.8V and 1.5V output voltages. Assuming the LTC1702 provides 90% efficiency at each output, the additional load on the 5V and 3.3V supplies is: 1.5V: 15W/90% = 16.6W/3.3V = 5A from 3.3V 1.8V: 3.6W/90% = 4W/5V = 0.8A from 5V 2.5V: 1.25W/75% = 1.66W/3.3V = 0.5A from 3.3V If the 5V and 3.3V supplies are each 94% efficient, the power lost in each supply is: 1.5V: 1.8V: 2.5V: 3.3V: 5V: 16.6W – 15W = 1.6W 4W – 3.6W = 0.4W 1.66W – 1.25W = 0.4W 17.55W – 16.5W = 1W 16W – 15W = 1W Total loss = 4.4W Total system efficiency = 51.35W/(51.35W + 4.4W) = 92.1% 100 EFFICIENCY (%) TotalOutputPower (100%) TotalOutputPower + TotalPowerLost The behavior of the load over time affects the efficiency strategy. Parasitic resistances in the MOSFETs and the inductor set the maximum output current the circuit can supply without burning up. A typical efficiency curve (Figure 15) shows that peak efficiency occurs near 30% of this maximum current. If the load current will vary around the efficiency peak and will spend relatively little time at the maximum load, choosing components so that the average load is at the efficiency peak is a good idea. This puts the maximum load well beyond the efficiency peak, but usually gives the greatest system efficiency over time, which translates to the longest run time in a battery-powered system. If the load is expected to be relatively constant at the maximum level, the components should be chosen so that this load lands at the peak efficiency point, well below the maximum possible output of the converter. VIN = 5V VOUT = 3.3V VOUT = 2.5V 90 VOUT = 1.6V 80 70 0 5 10 LOAD CURRENT (A) 15 1702 G01 Figure 15. Typical LTC1702 Efficiency Curves 1702fa 27 LTC1702 U W U U APPLICATIONS INFORMATION Maximizing Low Load Current Efficiency Low load current efficiency depends strongly on proper operation in discontinuous and Burst Mode operations. In an ideally optimized system, discontinuous mode reduces conduction losses but not switching losses, since each power MOSFET still switches on and off once per cycle. In a typical system, there is additional loss in discontinuous mode due to a small amount of residual current left in the inductor when QB turns off. This current gets dissipated across the body diode of either QT or QB. Some LTC1702 systems lose as much to body diode conduction as they save in MOSFET conduction. The real efficiency benefit of discontinuous mode happens when Burst Mode operation is invoked. At typical power levels, when Burst Mode operation is activated, gate drive is the dominant loss term. Burst Mode operation turns off all output switching for several clock cycles in a row, significantly cutting gate drive losses. As the load current in Burst Mode operation falls toward zero, the current drawn by the circuit falls to the LTC1702’s background quiescent level—about 3mA per channel. To maximize low load efficiency, make sure the LTC1702 is allowed to enter discontinuous and Burst Mode operation as cleanly as possible. FCB must be above its 0.8V threshold. Minimize ringing at the SW node so that the discontinuous comparator leaves as little residual current in the inductor as possible when QB turns off. It helps to connect the SW pin of the LTC1702 as close to the drain of QB as possible. An RC snubber network can also be added from SW to PGND. REGULATION OVER COMPONENT TOLERANCE/ TEMPERATURE DC Regulation Accuracy The LTC1702 initial DC output accuracy depends mainly on internal reference accuracy, op amp offset and external resistor accuracy. Two LTC1702 specs come into play: feedback voltage and feedback voltage line regulation. The feedback voltage spec is 800mV ± 8mV over the full temperature range, and is specified at the FB pin, which encompasses both reference accuracy and any op amp offset. This accounts for 1% error at the output with a 5V input supply. The feedback voltage line regulation spec adds an additional 0.05%/V term that accounts for change in reference output with change in input supply voltage. With a 5V supply, the errors contributed by the LTC1702 itself add up to no more than 1% DC error at the output. The output voltage setting resistors (R1 and RB in Figure 3) are the other major contributor to DC error. At a typical 1.xV output voltage, the resistors are of roughly the same value, which tends to halve their error terms, improving accuracy. Still, using 1% resistors for R1 and RB will add 1% to the total output error budget, equal to that of all errors due to the LTC1702 combined. Using 0.1% resistors in just those two positions can nearly halve the DC output error for very little additional cost. Load Regulation Load regulation is affected by feedback voltage, feedback amplifier gain and external ground drops in the feedback path. Feedback voltage is covered above and is within 1% over temperature. A full-range load step might require a 10% duty cycle change to keep the output constant, requiring the COMP pin to move about 100mV. With amplifier gain at 85dB, this adds up to only a 10µV shift at FB, negligible compared to the reference accuracy terms. External ground drops aren’t so negligible. The LTC1702 can sense the positive end of the output voltage by attaching the feedback resistor directly at the load, but it cannot do the same with the ground lead. Just 0.001Ω of resistance in the ground lead at 10A load will cause a 10mV error in the output voltage—as much as all the other DC errors put together. Proper layout becomes essential to achieving optimum load regulation from the LTC1702. See the Layout/Troubleshooting section for more information. A properly laid out LTC1702 circuit should move less than a millivolt at the output from zero to full load. TRANSIENT RESPONSE Transient response is the other half of the regulation equation. The LTC1702 can keep the DC output voltage constant to within 1% when averaged over hundreds of 1702fa 28 LTC1702 U U W U APPLICATIONS INFORMATION cycles. Over just a few cycles, however, the external components conspire to limit the speed that the output can move. Consider our typical 5V to 1.6V circuit, subjected to a 1A to 5A load transient. Initially, the loop is in regulation and the DC current in the output capacitor is zero. Suddenly, an extra 4A start flowing out of the output capacitor while the inductor is still supplying only 1A. This sudden change will generate a (4A)(CESR)voltage step at the output; with a typical 0.015Ω output capacitor ESR, this is a 60mV step at the output, or 3.8% (for a 1.6V output voltage). Very quickly, the feedback loop will realize that something has changed and will move at the bandwidth allowed by the external compensation network towards a new duty cycle. If the bandwidth is set to 50kHz, the COMP pin will get to 60% of the way to 90% duty cycle in 3µs. Now the inductor is seeing 3.5V across itself for a large portion of the cycle, and its current will increase from 1A at a rate set by di/dt = V/L. If the inductor value is 0.5µH, the di/dt will be 3.5V/0.5µH or 7A/µs. Sometime in the next few microseconds after the switch cycle begins, the inductor current will have risen to the 5A level of the load current and the output capacitor will stop losing charge. Note that the output voltage will stop dropping before the inductor current reaches this new output current level. Recall that any practical output capacitor looks like a pure capacitance in series with some amount of ESR. When a load transient hits, virtually all of the initial voltage drop at the output is due to IR drop across the ESR. The output capacitance begins to discharge at the same time and continues until the inductor current rises to match the new output current level. The output voltage, however, will turn around and start heading the right way before this happens. The next time the top MOSFET turns on, the inductor current will begin increasing linearly. This increasing current flows almost entirely into the capacitor, going through the ESR as it does so (Figure 16). Positive di/dt in the inductor causes positive dv/dt in the ESR, regardless of what the “pure” capacitance is doing. The output voltage will turn around when the positive dv/dt across the ESR exceeds the negative dv/dt across the pure capacitance. If the expected load step (∆I) is known, an optimum inductor value can be chosen: ( ) L ≤ VIN – VOUT • C • ESR ∆I IL IOUT IL IOUT VESR VESR VCAP VCAP IL VSW L COUT VOUT VOUT + VOUT VOUT(NOMINAL) VESR – + IOUT VCAP – 1702 F16b 1702 F16a Figure 16a. Capacitor Parasitics Affecting Transient Recovery TRANSIENT HITS VOUT TURNS AROUND IL > IOUT TIME Figure 16b. Transient Recovery Curves 1702fa 29 LTC1702 U W U U APPLICATIONS INFORMATION Making L smaller than this optimum value yields little or no improvement in transient response. As the output voltage recovers, the inductor current will briefly rise above the level of the output current to replenish the charge lost from the output capacitor. With a properly compensated loop, the entire recovery time will be inside of 10µs. Most loads care only about the maximum deviation from ideal, which occurs somewhere in the first two cycles after the load step hits. During this time, the output capacitor does all the work until the inductor and control loop regain control. The initial drop (or rise if the load steps down) is entirely controlled by the ESR of the capacitor and amounts to most of the total voltage drop. To minimize this drop, reduce the ESR as much as possible by choosing low ESR capacitors and/or paralleling multiple capacitors at the output. The capacitance value accounts for the rest of the voltage drop until the inductor current rises. With most output capacitors, several devices paralleled to get the ESR down will have so much capacitance that this drop term is negligible. Ceramic capacitors are an exception; a small ceramic capacitor can have suitably low ESR with relatively small values of capacitance, making this second drop term significant. VIN LTC1702 Optimizing Loop Compensation Loop compensation has a fundamental impact on transient recovery time, the time it takes the LTC1702 to recover after the output voltage has dropped due to output capacitor ESR. Optimizing loop compensation entails maintaining the highest possible loop bandwidth while ensuring loop stability. The Feedback Component Selection section describes in detail how to design an optimized feedback loop, appropriate for most LTC1702 systems. Voltage Positioning If the load transients consist primarily of load steps from near zero load to full load and back, the transient response can be traded off against DC regulation performance by using a technique known as “voltage positioning.” The goal is to intentionally compromise the DC regulation loop such that the output rides near the maximum allowable value (often +5%) with no load and near the minimum allowable value at maximum load. With the load at zero, any transient that comes along will be a current increase which will cause the output voltage to fall. Since the output voltage is initially at a high value, it can fall further before MAXIMUM ALLOWABLE TRANSIENT +5% VOUT NOM –5% VOUT MAX FB LOAD CURRENT 0 1702 F17a 1702 F17b Figure 17a. Standard Regulator Figure 17b. Standard Regulator—Transient Response VIN LTC1702 +5% VOUT NOM –5% MAXIMUM ALLOWABLE TRANSIENT ≈2× FIGURE 17b VOUT MAX FB LOAD CURRENT 0 1702 F17c 1702 F17d Figure 17c. Voltage Positioning Regulator Figure 17d. Positioning Regulator—Transient Response 1702fa 30 LTC1702 U W U U APPLICATIONS INFORMATION it goes out of spec. Similarly, at full load, the output current can only decrease, causing a positive shift in the output voltage; the initial low value allows it to rise further before the spec is exceeded. The primary benefit of voltage positioning is it increases the allowable ESR of the output capacitors, saving cost. An additional bonus is that at maximum load, the output voltage is near the minimum allowable, decreasing the power dissipated in the load. Implementing voltage positioning is as simple as creating an intentional resistance in the output path to generate the required voltage drop. This resistance can be a low value resistor, a length of PCB trace, or even the parasitic resistance of the inductor if an appropriate filter is used. If the LTC1702 senses the output voltage upstream from the resistance (Figure 17), the output voltage will move with load as I • R, where I is the load current and R is the value of the resistance. If the feedback network is then reset to regulate near the upper edge of the specified tolerance, the output voltage will ride high when ILOAD is low and will ride low when ILOAD is high. Compared to a traditional regulator, a voltage positioning regulator can theoretically stand as much as twice the ESR drop across the output capacitor while maintaining output voltage regulation. This means smaller, cheaper output capacitors can be used while keeping the output voltage within acceptable limits. Measurement Techniques Measuring transient response presents a challenge in two respects: obtaining an accurate measurement and generating a suitable transient to use to test the circuit. Output measurements should be taken with a scope probedirectly across the output capacitor. Proper high frequency probing techniques should be used. In particular, don’t use the 6" ground lead that comes with the probe! Use an adapter that fits on the tip of the probe and has a short ground clip to ensure that inductance in the ground path doesn’t cause a bigger spike than the transient signal being measured. Conveniently, the typical probe tip ground clip is spaced just right to span the leads of a typical output capacitor. In general, it is best to take this measurement with the 20MHz bandwidth limit on the oscilloscope turned on to limit high frequency noise. Note that microprocessor manufacturers typically specify ripple ≤ 20MHz, as energy above 20MHz is generally radiated and not conducted and will not affect the load even if it appears at the output capacitor. Now that we know how to measure the signal, we need to have something to measure. The ideal situation is to use the actual load for the test, and switch it on and off while watching the output. If this isn’t convenient, a current step generator is needed. This generator needs to be able to turn on and off in nanoseconds to simulate a typical switching logic load, so stray inductance and long clip leads between the LTC1702 and the transient generator must be minimized. Figure 18 shows an example of a simple transient generator. Be sure to use a noninductive resistor as the load element—many power resistors use an inductive spiral pattern and are not suitable for use here. A simple solution is to take ten 1/4W film resistors and wire them in parallel to get the desired value. This gives a noninductive resistive load which can dissipate 2.5W continuously or 50W if pulsed with a 5% duty cycle, enough for most LTC1702 circuits. Solder the MOSFET and the resistor(s) as close to the output of the LTC1702 circuit as possible and set up the signal generator to pulse at a 100Hz rate with a 5% duty cycle. This pulses the LTC1702 with 500µs transients 10ms apart, adequate for viewing the entire transient recovery time for both positive and negative transitions while keeping the load resistor cool. LTC1702 VOUT RLOAD PULSE GENERATOR IRFZ44 OR EQUIVALENT LOCATE CLOSE TO THE OUTPUT 50Ω 1702 F18 0V TO 10V 100Hz, 5% DUTY CYCLE Figure 18. Transient Load Generator 1702fa 31 LTC1702 U W U U APPLICATIONS INFORMATION FAULT BEHAVIOR Changing the Output Voltage on the Fly Some applications use a switching scheme attached to the feedback resistors to allow the system to adjust the LTC1702 output voltage. The voltage can be changed on the fly if desired, but care must be taken to avoid tripping the overvoltage fault circuit. Stepping the voltage upwards abruptly is safe, but stepping down quickly by more than 15% can leave the system in a state where the output voltage is still at the old higher level, but the feedback node is set to expect a new, substantially lower voltage. If this condition persists for more than 10µs, the overvoltage fault circuitry will fire and latch off the LTC1702. The simplest solution is to disable the fault circuit by grounding the FAULT pin. Systems that must keep the fault circuit active should ensure that the output voltage is never programmed to step down by more than 15% in any single step. The safest strategy is to step the output down by 10% or less at a time and wait for the output to settle to the new value before taking subsequent steps. VID Applications Certain microprocessors specify a set of codes that correspond to power supply voltages required from the regulator system. If these codes are changed on the fly, the same caveats as above apply. In addition, the switching matrix that programs the output voltage may vary its resistance significantly over the entire span of output voltages, potentially changing the loop compensation if the circuit is not designed properly. With a typical type 3 feedback loop (Figure 8), make sure that the RBIAS resistor is modified to set the output voltage. The R1 resistor must stay constant to ensure that the loop compensation is not affected. U TYPICAL APPLICATIONS 3.3VIN, 2.5V/1.8V Output Power Supply D1, D2: MOTOROLA MBR0520LT1 D3: MOTOROLA MBRS320T3 C1: KEMET T510X477M006AS C12, C20: PANASONIC EEFUE0G181R L1: SUMIDA CEP1254712-T007 L2: SUMIDA CDRH744734-JPS023 Q1A, Q1B, Q2A, Q2B: SILICONIX Si9804 Q3, Q4: 1/2 SILICONIX Si4966 R1 C4 10µF 10Ω D2 C6 1µF C8 1µF C5 1µF PVCC Q2A VOUT2 1.8V 12A Q2B D1 VIN 3.3V ± 5% C1 470µF ×2 C2 1µF R8 36k BOOST1 L1 0.68µH + IMAX2 BOOST2 BG1 BG2 TG1 TG2 C3 1µF Q3 VOUT1 2.5V 5A SW1 C12 180µF ×3 + C15 1µF D3 R3 4.3k R4 10k 1% Q1B R2 39k Q1A 10k Q4 PGOOD1 PGOOD2 C11 820pF FCB C7 1µF GND VIN SW2 LTC1702 IMAX1 PGND L2 1µH C16 1µF RUN/SS RUN/SS2 COMP1 R5 8.06k 1% PGOOD1 C19 1000pF SGND FB2 FB1 VCC C20 180µF C21 1µF R12 10.7k 1% R13 4.99k 1% COMP2 + VIN GND 10k PGOOD2 FAULT R9 27k R7 68k C10 100pF FAULT R10 2.4k C9 20pF C17 100pF C18 1000pF 1702 TA02 1702fa 32 C11 330pF COUT1 470µF ×2 VOUT1 1.8V 10A + R21, 13k R11 10k 0.1% Q21 Q11 CSS1 0.1µF RIMAX1, 22k D2 MBR330T CCP1 1µF 1µF CIN, COUT1, COUT2: KEMET T510X477M006AS C21 680pF RB1 7.96k 0.1% C31 560pF R31, 4.7k LEXT1 1µH 12A DCP1 MBR0530T RUN/SS1 GND CCP2 1µF CSS2 0.1µF + CIN 470µF ×2 LEXT1: MURATA LQT12535C1ROM12 LEXT2: COILTRONICS UP2B-2R2 RUN/SS2 PGND FB2 COMP2 COMP1 FB1 IMAX2 IMAX1 BG2 SW2 TG2 RIMAX2, 47k DCP2 MBR0530T BOOST2 PVCC BG1 LTC1702 SW1 TG1 BOOST1 VCC 10Ω VIN = 5V ±10% 28W Dual Output Power Supply Q22 R22, 20k R12 4.99k 0.1% RB2 1.62k 0.1% + VOUT2 3.3V 3A 1702 TA05 C12 120pF COUT2 470µF Q11, Q21: FAIRCHILD FDS6670A Q12, Q22: 1/2 SILICONIX Si9402 C22 270pF C32 820pF R32, 2.2k LEXT2 Q12 2.2µH 6A LTC1702 TYPICAL APPLICATIONS 1702fa 33 U 100k 10k 10k 1% VIN 4.75k 0.1% 0.01µF 0.01µF 0.1µF PGOOD 10k 4.7k 0.1µF TG2 RUN/SS1 FAULT SGND FCB BG2 PGND BG1 IMAX2 SW2 IMAX1 PGOOD2 RUN/SS2 BOOST2 SW1 BOOST1 PGOOD1 COMP2 FB2 + 33k 33k 1µF D1 0.1µF 0.1µF 10Ω CIN2 100µF TG1 PVCC LTC1702 COMP1 FB1 VCC CVCC 10µF 10Ω LT1006 + 34 – 1µF 10k 10k D3 D2 CIN1 10µF ×2 QB1A QT1A 0.004Ω 0.5W QB1B QT1B 0.004Ω 0.5W VIN 5V ±10% CIN1, COUT, CVCC: MURATA GRM235Y5V106Z CIN2: AVX TPSD107M010R0080 D1, D2, D3: MOTOROLA MBR0530T1 ALL MOSFETS: FAIRCHILD FDS6670A L1, L2: SUMIDA CEP125-0R47 Single Output, 2-Phase, Minimum Capacitors 5V to 2.5V/40A Converter QB2A QT2A 0.004Ω 0.5W QB2B L2 0.47µH L1 0.47µH QT2B 0.004Ω 0.5W COUT 10µF CER ×4 VOUT 2.5V 40A LTC1702 TYPICAL APPLICATIONS 1702fa U LTC1702 U PACKAGE DESCRIPTION GN Package 24-Lead Plastic SSOP (Narrow .150 Inch) (Reference LTC DWG # 05-08-1641) .337 – .344* (8.560 – 8.738) 24 23 22 21 20 19 18 17 16 15 1413 .033 (0.838) REF .045 ±.005 .229 – .244 (5.817 – 6.198) .254 MIN .150 – .157** (3.810 – 3.988) .150 – .165 1 .0165 ± .0015 2 3 4 5 6 7 8 9 10 11 12 .0250 BSC RECOMMENDED SOLDER PAD LAYOUT .015 ± .004 × 45° (0.38 ± 0.10) .0075 – .0098 (0.19 – 0.25) .0532 – .0688 (1.35 – 1.75) .004 – .0098 (0.102 – 0.249) 0° – 8° TYP .016 – .050 (0.406 – 1.270) NOTE: 1. CONTROLLING DIMENSION: INCHES INCHES 2. DIMENSIONS ARE IN (MILLIMETERS) .008 – .012 (0.203 – 0.305) TYP .0250 (0.635) BSC GN24 (SSOP) 0204 3. DRAWING NOT TO SCALE *DIMENSION DOES NOT INCLUDE MOLD FLASH. MOLD FLASH SHALL NOT EXCEED 0.006" (0.152mm) PER SIDE **DIMENSION DOES NOT INCLUDE INTERLEAD FLASH. INTERLEAD FLASH SHALL NOT EXCEED 0.010" (0.254mm) PER SIDE 1702fa Information furnished by Linear Technology Corporation is believed to be accurate and reliable. However, no responsibility is assumed for its use. Linear Technology Corporation makes no representation that the interconnection of its circuits as described herein will not infringe on existing patent rights. 35 LTC1702 U TYPICAL APPLICATION Low Cost Dual Supply with 2.5V Keepalive VIN 5V ±10% IN + 10Ω 4.75k 0.1% 10k 0.1% + 10µF VCC OUT LT1761 16.2k 0.1% GND ADJ MBR0530T PVCC FB2 330pF 68k 1µF CIN 16.9k 0.1% BOOST2 56pF L2 1µF QT2 TG2 COMP2 VOUT2 2.5V/7A 2.45V/100mA STANDBY SW2 RUN/SS2 RUN/SS1 1k QSS1 QSS2 STBY/ON 0.1µF BG2 47k + QB2 COUT2 IMAX2 FAULT LTC1702 BOOST1 1k 20k 1% 56k 220pF MBR0530T 1µF QT1B FB1 TG1 39pF COMP1 QT1A BG1 FCB 16k 1% L1 VOUT1 1.8V 20A SW1 + QB1A 33k COUT1 QB1B IMAX1 SGND PGND 1702 TA04 CIN = SANYO 10MV1200GX (6 IN PARALLEL) COUT1 = SANYO 6MV1500GX (8 IN PARALLEL) COUT2 = SANYO 6MV1500GX (3 IN PARALLEL) L1: 1µH SUMIDA CEP125-1R0MC-H L2: 2.2µH COILTRONICS UP2B-2R2 QSS1, QSS2: MOTOROLA MMBT3904LT1 QT1A, QT1B, QB1A, QB1B: FAIRCHILD FDS6670A QT2, QB2: 1/2 SILICONIX Si4966 RELATED PARTS PART NUMBER DESCRIPTION COMMENTS LTC1530 High Power Synchronous Step-Down Controller SO-8 with Current Limit. No RSENSE Required TM LTC1625 No RSENSE Current Mode Synchronous Step-Down Controller Above 95% Efficiency, Needs No RSENSE, 16-Lead SSOP Package Fits SO-8 Footprint LTC1628 Dual High Efficiency 2-Phase Synchronous Step-Down Controller Constant Frequency, Standby 5V and 3.3V LDOs, 3.5V ≤ VIN ≤ 36V LTC1703 Dual 550kHz Synchronous 2-Phase Switching Regulator Controller LTC1702 with 5-Bit Mobile VID for Mobile Pentium® Processor with Mobile VID Systems LTC1706-81 VID Voltage Programmer LTC1709 2-Phase, 5-Bit Desktop VID Synchronous Step-Down Controller Current Mode, VIN to 36V, IOUT Up to 42A LTC1736 Synchronous Step-Down Controller with 5-Bit Mobile VID Control Fault Protection, PowerGood, 3.5V to 36V Input, Current Mode LTC1753 5-Bit Desktop VID Programmable Synchronous Switching Regulator 1.3V to 3.5V Programmable Output Using Internal 5-Bit DAC LTC1873 Dual Synchronous Switching Regulator with 5-Bit Desktop VID 1.3V to 3.5V Programmable Core Output Plus I/O Output LTC1929 2-Phase, Synchronous High Efficiency Converter Current Mode Ensures Accurate Current Sensing, VIN Up to 36V, IOUT Up to 40A Adds 5-Bit Mobile VID to 0.8V Referenced Switching Regulators No RSENSE is a trademark of Linear Technology Corporation. Pentium is a registered trademark of Intel Corporation. 1702fa 36 Linear Technology Corporation 1630 McCarthy Blvd., Milpitas, CA 95035-7417 (408) 432-1900 ● FAX: (408) 434-0507 ● www.linear.com LT 0306 REV A • PRINTED IN USA © LINEAR TECHNOLOGY CORPORATION 1999
LTC1702CGN 价格&库存

很抱歉,暂时无法提供与“LTC1702CGN”相匹配的价格&库存,您可以联系我们找货

免费人工找货